Tender For Special Repair Of Hvac System Installed For Trauma Centre, Ims, Banaras Hindu University, Varanasi (U.P.), varanasi-Uttar Pradesh

Banaras Hindu University-BHU has published Tender For Special Repair Of Hvac System Installed For Trauma Centre, Ims, Banaras Hindu University, Varanasi (U.P.). Submission Date for this Tender is 29-12-2023. HVAC Tenders in varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41259544
Tender For Special Repair Of Hvac System Installed For Trauma Centre, Ims, Banaras Hindu University, Varanasi (U.P.)
Open Tender
Indian
Uttar Pradesh
varanasi
29-12-2023

Tender Details

Tender For Special Repair Of Hvac System Installed For Trauma Centre, Ims, Banaras Hindu University, Varanasi (U.P.)

Key Value

Document Fees
INR 500 /-
EMD
INR 84718.0 /-
Tender Value
INR 42.35 Lakhs /-

BOQ Items

Name of Work:- Special Repair of HVAC System installed for Trauma Centre, IMS, Banaras Hindu University, Varanasi (U.P.)
Sl. No. Item Description
1Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
2Providing & fixing in position the mercury in glass industrial type thermometers.
3Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 80 mm dia.
4SITC Of Lube oil
5SITC Of Oil Filter
6SITC Of Shut off Valve
7SITC Of Drier Core
8Supply and fixing of Canvas connection of OT - 2 AHU of 3000 CFM (400x400MM) Fire proof material
9Overhauling of Secondary Chilled Water Pump (25HP) including dismantling, replacement of defective bearings, remetaling of shaft, polishing, reassembling and commissioning of the same.
10Overhauling of Hot Water Pump (7.5HP) including dismantling, replacement of defective bearings, Mechanical seal remetaling of shaft, polishing, reassembling and commissioning of the same.
11Repairing of the Basin of Cooling tower including supply of resin and other chemicaland parts complete as Per below. FRP SEALING Compound
12Repairing of the Basin of Cooling tower including supply of resin and other chemicaland parts complete as Per below. Splash Cap withsteel screw
13Repairing of the Basin of Cooling tower including supply of resin and other chemicaland parts complete as Per below. PVD END CAP 63 mm dia.
14Repairing of the Basin of Cooling tower including supply of resin and other chemicaland parts complete as Per below. PVC pipe 63MM X10 feet long
15Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,. Evaporative cooling Pad
16Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,. Roof and base 35 MM thick insulated with supporting frame
17Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,. One mono block pump (0.5HP ) make ;Crompton
18Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,. Pre Filter of size( 675X665X50)MM
19Supply and fixing of Canvas connection of Air Washer(1200X1200 MM) Wire proof.
20Descaling and cleaning of cooling coil/Heating Coil of AHUs/CSUs with the help of descaling compound, soft cleaning agent, pressure pump etc. as required.
21Descaling and cleaning of cooling coil/Heating Coil of FCUs with the help of descaling compound, soft cleaning agent ,pressure pump etc. as required.
22Dismantling, repairing and fixing of Heating Coil of AHU installed in OT - 7 including lifting shifting of the same to the storage.
23Dismantling, repairing and fixing of Cooling Coil of CSU installed in Blood Bank including lifting shifting of the same to the storage.
24SITC ofThermostat of FCU Unit (Make: Honeywell/ Siemens/ Equivalent)
25SITC of( 300mmx575mm) With circular frame Stainless Steel Pot Strainer Jali
26SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 50 MM
27SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 65 MM
28SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 80 MM
29SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 100 MM
30SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 125 MM
31SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 150 MM
32SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 200 MM
33SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 250 MM
34SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 300 MM
35Humidity andtemperature device with display make -Siemens ,Honeywell
Disclaimer :