Banaras Hindu University-BHU has published Tender For Special Repair Of Hvac System Installed For Trauma Centre, Ims, Banaras Hindu University, Varanasi (U.P.). Submission Date for this Tender is 29-12-2023. HVAC Tenders in varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required |
2 | Providing & fixing in position the mercury in glass industrial type thermometers. |
3 | Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 80 mm dia. |
4 | SITC Of Lube oil |
5 | SITC Of Oil Filter |
6 | SITC Of Shut off Valve |
7 | SITC Of Drier Core |
8 | Supply and fixing of Canvas connection of OT - 2 AHU of 3000 CFM (400x400MM) Fire proof material |
9 | Overhauling of Secondary Chilled Water Pump (25HP) including dismantling, replacement of defective bearings, remetaling of shaft, polishing, reassembling and commissioning of the same. |
10 | Overhauling of Hot Water Pump (7.5HP) including dismantling, replacement of defective bearings, Mechanical seal remetaling of shaft, polishing, reassembling and commissioning of the same. |
11 | Repairing of the Basin of Cooling tower including supply of resin and other chemicaland parts complete as Per below. FRP SEALING Compound |
12 | Repairing of the Basin of Cooling tower including supply of resin and other chemicaland parts complete as Per below. Splash Cap withsteel screw |
13 | Repairing of the Basin of Cooling tower including supply of resin and other chemicaland parts complete as Per below. PVD END CAP 63 mm dia. |
14 | Repairing of the Basin of Cooling tower including supply of resin and other chemicaland parts complete as Per below. PVC pipe 63MM X10 feet long |
15 | Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,. Evaporative cooling Pad |
16 | Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,. Roof and base 35 MM thick insulated with supporting frame |
17 | Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,. One mono block pump (0.5HP ) make ;Crompton |
18 | Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,. Pre Filter of size( 675X665X50)MM |
19 | Supply and fixing of Canvas connection of Air Washer(1200X1200 MM) Wire proof. |
20 | Descaling and cleaning of cooling coil/Heating Coil of AHUs/CSUs with the help of descaling compound, soft cleaning agent, pressure pump etc. as required. |
21 | Descaling and cleaning of cooling coil/Heating Coil of FCUs with the help of descaling compound, soft cleaning agent ,pressure pump etc. as required. |
22 | Dismantling, repairing and fixing of Heating Coil of AHU installed in OT - 7 including lifting shifting of the same to the storage. |
23 | Dismantling, repairing and fixing of Cooling Coil of CSU installed in Blood Bank including lifting shifting of the same to the storage. |
24 | SITC ofThermostat of FCU Unit (Make: Honeywell/ Siemens/ Equivalent) |
25 | SITC of( 300mmx575mm) With circular frame Stainless Steel Pot Strainer Jali |
26 | SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 50 MM |
27 | SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 65 MM |
28 | SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 80 MM |
29 | SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 100 MM |
30 | SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 125 MM |
31 | SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 150 MM |
32 | SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 200 MM |
33 | SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 250 MM |
34 | SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MKfor indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 300 MM |
35 | Humidity andtemperature device with display make -Siemens ,Honeywell |