| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits andthe like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: |
| 2 | Providing & Laying of stone soling (dully hand packed)including watering dressing and ramming, including all carriages and head load complete. |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) including all carriages complete. |
| 4 | Filling under floors by Nallah Muck including watering, consolidation and all other carriages, complete job |
| 5 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing andreinforcement. All works upto plinth level using 1:1½:3 (1 cement: 1% coarse sand: 3 graded stone aggregate 20 mm nominal size) including all carriages complete. |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement: 1½coarse sand : 3 graded stone aggregate 20 mm nominal size) including all carriages complete. |
| 7 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:13:3 (1 cement: 1% coarsesand: 3 graded stone aggregate 20 mm nominal size) including all carriages complete. |
| 8 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) including all carriages complete. |
| 9 | Centering and shuttering incl. strutting, prooping etc and removal of same for Foundations, footings, bases for columns |
| 10 | Centering and shuttering incl. strutting, prooping etc and removal of same for Suspended floors, roofs, balconies and access platforms |
| 11 | Centering and shuttering incl. strutting, prooping etc and removal of same for Columns, pillars, piers, abutments, posts and struts. |
| 12 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 infoundation and plinth including curing in superstructure above plinth level upto floor five level, Cement mortar 1:6 ( 1 cement: 6 coarse sand) including all carriages complete. |
| 13 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately), Imported Wood |
| 14 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with14 necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges andnecessary screws shall be paid separately). Imported Wood 30 mm thick windows |
| 15 | Providing and fixing panelling or panelling and glazing in panelled or panelled andglazed shutters for doors, windows and clerestory windows (Area of opening forpanel inserts excluding portion inside grooves or rebates to be measured).Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. |
| 16 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concreteblock 30x10x15 cm 1:3:6 mix ( 1 cement: 3 coarse sand: 6 graded stone aggregate20 mm nominal size). |
| 17 | 15mm Cement Plaster on the rough side of single or half brick wall of mix 1:6(1 cement:6 fine sand) |
| 18 | 18 6 mm cement plaster to ceiling of mix 1:3 (1 cement: 3 fine sand) |
| 19 | Extra for providing glass panes) of ordinary glass panes windows and clerestory window shutters wt 10 Kg/sqm (Area of opening for glass panes excld portioninside shall be measured) |
| 20 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 21 | Applying priming coot with ready mixed Pink or grey primer of approved brand and manufacture on WOOD work (hard or soft wood) |
| 22 | Painting with synthetic enamel paint of app. Brand & manufacture to give an evenshade 2 or more coats on new work |
| 23 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level and above using Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 24 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 25 | Providing & fixing Precoated galvalume profile sheets 0.50 mm TCT having a crestheight of 28-32mm at 195mm pitch and effective width of 975-1000mm and length to suit site requirement to the purlins using self drilling and self tapping fasteners of reputed make with purlin sheet using self drilling and self tapping fastners & Fixing flashings, valleys and ridges of colour coated galvalume plain sheet using self drilling and self tapping fasteners of reputed makel complete and as directed. The contractor shall give a minimum of 10 years guarantee for sheets againstdeterioration, disintegrations loss of luster, variation in colour, etc. and leakagesacross laps, fasteners etc. All types of steel sheets shall be load tested to satisfy1.10 times the design wind load and coating thickness to the satisfaction of theEngineer-in-Charge. Fasterners shall also be load tested. The Contractor is to submitdesign and shop drawings for approval on the sheet profile, design and fabricationdetails before installation (including cost of all material, leads, lifts and carriagesetc upto site of work complete).110 |
| 26 | Providing hardware items of approved quality i/c link locksConcield Locks |
| 27 | Handles 6\" |
| 28 | Handles 4\" |
| 29 | T Bolts 4\" |
| 30 | T Bolts 6\" |
| 31 | Hooks |
| 32 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubeschannels, plates etc. including welding grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 33 | Cement Concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone agg) finished with a floating coat of neat cement incid. cement slurry but excid the costof nosing of steps etc complete 50mm thick with 20mm nominal size stone agg crushed, including all carriages complete. |
| 34 | Making plinth protection50 mm thick of cement concrete 1:3:6 with 20 mm nominal size aggrigates over 75 mm bed of dry brick ballast 40 mm nominal size well rammed, consolidated & grouted with the fine sand i/c finishing the top smooth, including all carriages complete. |
| 35 | Providing and laying of 25mm PVC conduit for laying of wiring including all alliedaccessories and necessary taping and deep/concealed junction boxes. |
| 36 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curingcomplete with base of cement mortar 1:4 (1 cement: 4 coarse sand): |