Tender For Provn Of Shed Near Ch Washing Area Otm Bldg No P-85 A At Od Complex, Provn Of Security/Road Lights A/W Side Of The Road Connecting From Abdul Hamid Line (Nhl) To Balaji Puram Gate And Provn Of Cooling Appliances For Conf Hall Under Ge (E), mathura-Uttar Pradesh

Military Engineer Services-MES has published Tender For Provn Of Shed Near Ch Washing Area Otm Bldg No P-85 A At Od Complex, Provn Of Security/Road Lights A/W Side Of The Road Connecting From Abdul Hamid Line (Nhl) To Balaji Puram Gate And Provn Of Cooling Appliances For Conf Hall Under Ge (E). Submission Date for this Tender is 17-01-2024. Shed Construction Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41238996
Corrigendum : Tender For Provn Of Shed Near Ch Washing Area Otm Bldg No P-85 A At Od Complex, Provn Of Security/Road Lights A/W Side Of The Road Connecting From Abdul Hamid Line (Nhl) To Balaji Puram Gate And Provn Of Cooling Appliances For Conf Hall Under Ge (E)
Open Tender
Indian
Uttar Pradesh
mathura
17-01-2024

Tender Details

Provision Of Shed Near Cook House Washing Area Otm Bldgno P-85 A At Od Complex, Provision Of Security / Road Lights Along With Side Of The Road Connecting From Abdul Hamid Line ( Nhl ) To Balaji Puram Gate And Provn Of Cooling Appliances For Conf Hall, Server ( Internet ) Room, Plotter Room Of Architect Sec Under Ge ( East ) Mathura

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Dec-2023 Corrigendum BOQ 10-01-2024
2 10-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 28000.0 /-
Tender Value
INR 14 Lakhs /-

BOQ Items

Name of Work : PROVN OF SHED NEAR COOK HOUSE WASHING AREA OTM BLDGNO P-85 A AT OD COMPLEX, PROVN OF SECURITY/ROAD LIGHTS ALONGWITH SIDE OF THE ROAD CONNECTING FROM ABDUL HAMID LINE (NHL) TO BALAJI PURAM GATE AND PROVN OF COOLING APPLIANCES FOR CONF HALL, SERVER (INTERNET) ROOM, PLOTTER ROOM OF ARCHITECT SEC UNDER GE (EAST) MATHURA
Sl. No. Item Description
1Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers n. exc. 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface in soft/loose soil Complete all as specified and directed.
2M&L for cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in foundation filling and mass concrete Complete all as specified and directed.
3M&L for Mild steel work in tubular trusses, purlins, vetical posts including special shaped washer, angle cleats, fish plates, gusset plates, base/ bearing plates, bolts and nuts etc. complete using ERW or induction butt welded tubes conforming to 1161-1979 grade st 240 Complete all as specified and directed.
4S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165) for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc 7 for ornamental and intricate design. Complete all as specified and directed .
5M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws Complete all as specified and directed.
6M&L Pre- painted galvalume aluminium zinc coating GI basedsteel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpaas in ridges/valley gutters, fixed with self tapping screw Complete all as specified and directed.
7M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primerComplete all as specified and directed.
8Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection complete
9Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & washers made out of mild steel tubing, type 410 SP -31 (9 Mtr long) including marking pole No on pole including painting of poles with one coat of red oxide primer and two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and as directed. Note : Earth work and PCC in foundation and coping of pole included.
10Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and as directed.
11Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and as directed.
12Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and as directed.
13Material and labour street light fitting bracket made out of 40mm bore GI pipe, light grade, tubing bend to shape, 1.2 metre long, fixed to pole/wall with and including two sets of clamps made out of flat iron of size 50 x 6 mm with bolts, nuts and washers complete all as specified and directed.
14Supply and fixing junction box out door type of external dimensions 250 mm x 200 mm x 105 mm, single door type hinged with locking arrangement front operated, 3 phase and neutral bus bar including connecting the incoming/out going cables with nuts, bolts etc complete all as specified and directed. Make - Sinitex or equivalent as approved by GE.
15Supplying and fixing in replacement 1100 volts grade heavy duty cable of size 6.0 Sqmm twin core PVC insulated aluminium conductor, flat, served with inner sheathing of PVC tape and overall PVC sheathed in service connections for providing electrical connections to existing security/street lights complete all as specified and directed.
16Supply, installing, commissioning and testing LT Feeder Piller Boxoutdoor,double door cubical panel board suitable for 3 phase 4 wire 415 V, 50 Hz and CPRI approved factory fabricated powder coating having thickness not less than 100 microns provided withprovided with suitable gasket to make it dust/vermin proof including danger notice board ,pcc 1:2:4 type B-1 as in foundation ,incoming ( I/C ) and outgoing (O/G) cable connection and general construction confirming to IS- 8623/93 comprising of the following:-OUTER SHELL:- The outer shell shall be made out of 3.15 mm thick CRCAsteel sheet,factory fabricated with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air U type gasket shall be used to make the outer shell compkletely vermin proof the bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with gland provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safety shall be made the degree of protection of outer shell shall be IP-54 INNER SHELL:Inner Shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear ,the inner shell completly vermin proof & to accomodate incommer/outgoing MCCB and TPN aluminium bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve .all controll wire shall be with 1.5 sqmm multistrand copper conductor and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs.
17A detachable predrilled gland plate of thckness 3.15 mm powder coated should be used at the bottom . the inner shell shall be of powder coated .The degree of protection for inner shell shall be IP-42 including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following:-(a) MCCB 100 Amp 25 KA , 4 pole, Ics=100%Icu -01 No (in coming) (b) MCCB63 Amp 16 KA , 3 pole(Adjustable thermal and Adjustable magnetic (O/G)-02 Nos (e) Digital meter with voltmeter (0-500)-01 Each (f) Rating of CT & Ammeter as per Bus bar capacity as mentioned (g) Selector Switch for Ammeter (R,Y&B)-01 Set(h) Selector Switch for Voltmeter (RY,YB,BR) -01 Set (I) Indicating Lamps (R,Y,B) -01 Set
18Supply,installing,commissioning and testing LT panel board outdoor type, cubical type made out CRCA sheet 3.15 mm thick dust and vermin proof and angle iron of suitable size, pedestal flame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with 200 Amp rated aluminum bus bar of of suitable size,(in separate chamber) including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following:- (a) MCCB63 Amp , 4 pole-01 Each (01 I/coming) (b)MCB DP 40Amp -02 Each (c) Digital Amp meter (0-250)-01 Each (d) Digital Volt meter (0-500) -01 Each (e) RYB Indicator-01 Set (e) Timer switch
19Excavation in trenches for laying under ground cable, erection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and as directed.
20Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thickcomplete all as specified and as directed.
21Removing surplus excavated material to a distance not exceeding 50 meter above the starting point complete all as specified and as directed.
22M&L Sand cushioning to under ground cable in trenches/existing cable trenches/ductsin layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and as directed.
23Supply and Laying Unreinforced precast concrete cable cover class LVtype 1, size 250mmx150mmx40mm complete all as specified and as directed.
24Supply, installing, commissioning and testing Split type Air Conditioner of nominal capacity 1.5 TR,compressor, remote operated suitable for working on 230 volts, single phase,50 HZ supply and 5 star energy rated complete including cutting/drillingof wall, providing stand for outdoor unit and making good disturbed surface of wall etccomplete all as specified and as directed.
25Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type& designed for input variation between 170 Vto 250 V with output voltage stabilized at 230 Vwith accuracy of ± 2.5% and of capacity 5 KVAcomplete all as specified and as directed.
26Supply and Fix metal Clad sheet metal plug and socket with a 2 pin and earth plug and 20 Amps SP MCB including makuing all conection complete all as specified and as directed.
27S&F submain wiring with two single core cable PVC insulated unsheathed copper multi standard conductor FRLS cable of size 4 sqmm , 1100 volt gradedrawing through and including conduit 20 mm dia medium duty including acessories such as Tee,bend,elbow etc ISI marked with and includingPVC insulated 4.0 sqmm unsheathed multistranded FR-LS Copper conductor cable for earth continuity and connected to common earth dolly etc. complete all as specified and as directed.
28S&F 4 Pole MCCB 100 to 125 Amp, 50 Hz, 415 V with rupturing capacity 35 KA. complete all as specified and as directed.
29Supply and Fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting vertical typeTPN,4 way 230 volts with 200 Amps rated bus bar suitable for fixing MCCBs,MCBs,isolatoretc complete all as specified and as directed.
30Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor laid in trenches / pipes, fixed topoles / walls, fixing with suitable saddle/clamps complete all as directed including taking out the old burnt out cables all as directed of size 16 sqmm 4 core complete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail