Tender For Repair And Replacement Of Lt Oh Lines, Lt Ug Cable, Lt Pole, Cross Arms, Lt Insulators, Painting Of Lt Poles, Apfc Panels, Street Lights And Allied Services In Od Technical And Domestic Area And Repair And Maint Of Ceiling Fans And Allied, avadi-Tamil Nadu

Military Engineer Services-MES has published Tender For Repair And Replacement Of Lt Oh Lines, Lt Ug Cable, Lt Pole, Cross Arms, Lt Insulators, Painting Of Lt Poles, Apfc Panels, Street Lights And Allied Services In Od Technical And Domestic Area And Repair And Maint Of Ceiling Fans And Allied. Submission Date for this Tender is 23-01-2024. Insulators Tenders in avadi Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

41198852
Corrigendum : Tender For Repair And Replacement Of Lt Oh Lines, Lt Ug Cable, Lt Pole, Cross Arms, Lt Insulators, Painting Of Lt Poles, Apfc Panels, Street Lights And Allied Services In Od Technical And Domestic Area And Repair And Maint Of Ceiling Fans And Allied
Open Tender
Indian
Tamil Nadu
avadi
23-01-2024

Tender Details

Repair And Replacement Of Lt Oh Lines, Lt Ug Cable, Lt Pole, Cross Arms, Lt Insulators, Painting Of Lt Poles, Apfc Panels, Street Lights And Allied Services In Od Technical And Domestic Area And Repair And Maint Of Ceiling Fans And Allied Works At Af

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-01-2024
2 18-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work :REPAIR & REPLACEMENT OF LT OH LINES, LT UG CABLE, LT POLE, CROSS ARMS, LT INSULATORS, PAINTING OF LT POLES, APFC PANELS, STREET LIGHTS AND ALLIED SERVICES IN OD TECHNICAL AND DOMESTIC AREA AND REPAIR AND MAINT OF CEILING FANS AND ALLIED WORKS AT AIR FORCE STATION AVADI
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft / loose soil for laying cables / pipes / erection of poles etc all as specified and as directed.
2Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
3Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
4Laying in trenches fine sieved excavated dry soilincluding spreading / leveling, cushioning for underground cables all as specified and as directed.
5Supply and laying of common burnt clay building bricks, sub class B of size 230x115x75mm for cable protection all as specified and as directed.
6Material and labour for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, 3.5/4 in replacement of the following sizes cross-sectionl area including taking down of old unserviceable cable complete all as specified and as directed:-, (NOTE : Earth work including excavation ,returning Filling,removing,sand coushioning,brick covering for mechanical protection of cable etc will be measured and paid separately under respective items of schedule
716 sq mm 4 core
825 sq mm 4 core
935 sq mm 3.5 Core
1050 sq mm 3.5 Core
1170 sq mm 3.5 Core
12Supply ,Fabricate, install, connect, test and commissioning Busbar chamber, powder coated, outdoor weather proof type, compartmentalised fabricated with3 mm thick CRCA steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit , chamber for aluminium busbars, separate compartment for switch gear,louvers and air vent for natural air flow, holes drilled for connection including suitable angle iron/flat iron frame work/ supports, excavation, earth work, PCC foundation etc., as required with and including following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including taking down the old busbar chamber and demolition of old plain cement concrete complete all as specified and comprising of the followings:- (i) 4 Nos busbar ofequal size of Aluminium conductor with PVC coloured heat shrinkable type sleeves continuous rating of400 Ampsmounted on fibre reinforced insulator.(1set), with LED indication lamps-03 Nos for RYB phases on incoming side. (ii)MCCB fixed thermal magnetic release type of capacity 200 amps, 4 pole,36 kA.- 1 Nos. Note :MCCB shall be front handle operated.
13Material and labour for 1100 volts grade heavy duty cable PVC insulated , PVC sheathed , fire resistant, round ,copper conductor, 3 core industrial cable of size 1.50 sqmm including taking down the old one complete all as specified and as directed.
14All asper Item No 8 above but of size 2.50 sqmm including taking down the old one complete all as specified and as directed.
15Repair and welding work the existing panel board door with provision of new door by taking down the old rusted door and providedhinges for door,if necessary and lock arrangement with provision of suitable size of sliding bolt and cleaning the welding surfaces by rubbing and polishing with two coat of synthetic enamel paint to match with existing colour all as specified and as directed.
16Repair to the existing LT panel boardwith provision of new lugs,bolt , nuts and washers suitable for size of cable from 4/3.5 core x 10 Sqmm to 240 Sqmm by taking down the old burnt/rusted lugs, bolts , nuts and washers in necessary quantityas per site requirment includingcleaning the busbars, provision of insulation sleeves to busbars where ever required complete all as specified and as directed.
17Earthing complete with galvanised steel earth plate eletrode 60xm x 60cm x6 mm thick buried directly in ground (earth plate not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth strip 25x4mmby means of bolts, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x6mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, charcoal and common salt filling, with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 meterrs, complete all as per plate No-3, SSR-2009 Part-I and connecting to existing earth test point all as specified or indicated including testing on completion.
18Earthing complete with galvanised steel earth plate eletrode 60xm x 60cm x6 mm thick buried directly in ground (earth plate not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x6mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, charcoal and common salt filling, with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 meterrs, complete all as per plate No-3, SSR-2009 Part-I and connecting to existing earth test point all as specified or indicated including testing on completion.
19Material and labour for GI tubing light grade for cable protection laid in trenches in road crossing or fixed to wall/Pole of following sizes including taking down old unserviceable one complete all as specified and as directed.
20Bore of tube 25mm
21Bore of tube 40mm
22Bore of tube 50mm
23Material and Labour for preparation of old painted surfaces ,removing dust and other deposited materials by scraping from LT panel inner and outer surface of front and rear doors including all compartment of MCCBs,busbar chamber,cable tray etcwith one coat of same existingcolour synthetic enamel paint by means of spray gun complete all as specified and as directed.
24Material and Labour for preparation of old painted surfaces ,removing dust and other deposited materials by scraping from busbar chamber inner and outer surface of front and rear doors includingcompartment of MCCB,busbar chamber with one coat of same existingcolour synthetic enamel paint by means of spray gun complete all as specified and as directed.
25Material and Labour for preparation of old painted surfaces ,removing dust and other deposited materials by scraping from LT tubular pole of 7.5 Mtr long above ground level , painting of pole with one coat of black paint upto 1 Mtr from bottom and painting the rest of the pole with one coat of aluminium paint including cross arms cable protection pipe clamps etc , including writing the MES No with white paint over black band of paint at a level of 1.2 m above ground level on each polecomplete all as specified and as directed.
26Material and Labour for preparation of old surface of PCC electric pole 7.5 m long above ground level applying two coats of cement based paint on pole and painting two coats with aluminium paint on cross arms,clamps, etc, including writing the MES No with white paint over black band of paint at a level of 1.2 m above ground level on each pole complete all as specified and directed.
27Material and Labour forMCCB 160 amps ,4 pole 415 volts ,3 phase ,50 Hz AC with adjustable thermalsetting& 36 KA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version). The MCCB should have Ics= 75% Icu for short circuit breaking capacity of minimum 36 KA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as standard feature of manufacturer including taking down old unserviceable one complete all as specified and as directed.
28All as per Item No 19 above but of capacity200 amps
29All as per Item No 19 above but of capacity250 amps
30All as per Item No 19 above but of capacity400 amps
31Supply and Fixing of LED street light fitting,230 V,AC,45 W, LED, outdoor type,CCT not less 6000K high pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 65/ 66 protection LED lumen efficacy not less then 120lumen/watt, reflector lenses for uniform light distribution on each LED with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete fixed on existing / New bracket and making connections including taking down the old one complete all as specified and as directed . Make: Shakti Cat part No:SZPSLPM045, Havells Cat Part No:ENDURASUNDOWNSL45WLED765PASYBOPC, Crompton Product No: TRP-409-45-57-SL-NS-GL-NSG or Equvalent.
32Supply and Fixing of LED street light fitting,230 V,AC,60 W, LED, outdoor type,CCT not less 6000K high pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 65/ 66 protection LED lumen efficacy not less then 120lumen/watt, reflector lenses for uniform light distribution on each LED with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete fixed on existing / New bracket and making connections including taking down the old one complete all as specified and as directed . Make: Shakti Cat part No:SZPSLPM060,Havells Cat Part No: ENDURAOMNIPLUSSL60WLED757SASYTOPC, Crompton Product No: TRP-409-60-57-SL-GL-NSG or Equvalent.
33Supply and Fixing of LED flood light fitting,230 V,AC,120 W, LED, outdoor type,CCT not less 6000K high pressure die cast aluminium housing ,heat resistance toughened glass with frame IP66 protection LED lumen efficacy not less then 120lumen/watt, reflector lenses for uniform light distribution on each LED with driver,lamp, bracket with impact and corrosion resistant including thermal management in multiple optics complete fixed on existing / New bracket and making connections including taking down the old one complete all as specified and as directed. Make: Shakti Cat part No:SZCFLMH120, Havells Cat Part No: JETAIRISFL120WLED757ARNBLDG, Crompton Product No:TFS-504-120-57-60D-SL-GL-NSG or Equvalent.
34Supply and Fixing of LED post top lantern,230 V,AC,40 W, LED, outdoor type,360 degree indirect light,CCT not less 6000K high pressure die cast aluminium housing ,heat resistance toughened glass with frame IP65 protection LED lumen efficacy not less then 120lumen/watt, reflector lenses for uniform light distribution on each LED with driver,lamp, bracket with impact and corrosion resistant including thermal management in multiple optics complete fixed on existing / New bracket and making connections including taking down the old one complete all as specified and as directed . Make: Shakti Cat part No:SZPGPMX040, Havells Cat Part No: RUBYPT40WLED757PSYMTOPC, Crompton Product No: LPTO-40-CDL or Equvalent.
35Supply and Fixing MCB,240V,10KA,"B" curve,single pole,current carrying capacity 5Amps, suitable for fixing in SMC box for control street/flood lights and making connections including taking down the old one complete all as specified and as directed.
36Supply and Fixing of pole mounted Sheet Moulded Compound(SMC) Box weather proof type with hinged type door off white color of size 250x250x155 mm comprising of 1 No MCB 6A andsuitable size Aluminium busbar 3 rows with terminals,1 No bakelite base neutral link and 01 No earthing terminal bolt and nut and connecting up cables with aluminium terminal lugscomplete fixed on pole with suitable clamps, bolts and nuts including taking down the old one complete all as specified and as directed.
37Cutting/clearing and removing the vegetation/bush/creepers growth any nature/type around/on the electric panel/feeder pillar box/busbar chamber so as to keep clean the area for easy access to carry out repair/maintenance works in electric panel/feeder pillar box/busbar chamber etc, removing from site and throwing out at a place where directed at distance not exceeding 250mtr away complete all as specified and as directed.
38Taking down carefully the Ceiling fanof any size/ make after disconnecting the electric connections for necessary servicing and replacing the spares, rewinding etc., all as specified and directed. Note: Servicing, Spares, Refixing and Rewinding shall be measured and paid for separately.
39Taking down carefully the Exhaust fanof any size/ make after disconnecting the electric connections for necessary servicing and replacing the spares, rewinding etc., all as specified and directed. Note: Servicing, Spares, Refixing and Rewinding shall be measured and paid for separately.
40Taking down carefully the Wall-mounted/ Air-circulator fansof any size/ make after disconnecting the electric connections for necessary servicing and replacing the spares, rewinding etc., all as specified and directed. Note: Servicing, Spares, Refixing and Rewinding shall be measured and paid for separately.
41Labour only for servicing the ceiling of any size/ make includinggreasing/ oiling/repairs and replacing the spares such as cater pin unserviceable/rusted nut bolts, split pins rubber wheel bearing washers, bush , and connected items all as specified and directed
42Hanging only ceiling fan any sweep any make, 230 V single phase and connecting up with PVC insulated cable size 1.50 sqmm three core copper conductor round cable complete all as specified. Note:- The refixed fan shall be tested after fixing the blades.
43Fixing only Exhaust fans along with louver any description any make,230 V single phase and connecting up with PVC insulated cable size 1.50 sqmm three core copper conductor round cable including grouting of nut, bolt on existing location andcomplete all as specified and directed. Note : The refixed fan shall be tested after fixing the blades.
44Fixing only Wall-mounted/ Air-circulator fans of any description any make, 230 V single phase and connecting up with PVC insulated cable size 1.50 sqmm three core copper conductor round cable including necesary fixing arrangements if existing fixing arrangements found unserviceable, on existing location etc., complete all as specified and as directed. Note : The refixed fan shall be tested after fixing the blades.
45Material and Labour for painting of ceiling fans of any sweep to obtain even, smooth & glossy finish, with synthetic enamel paint of approved colour by using paint spraying devices after filling cavities with filler after cleaning all dust etc., over fan surfaces; complete including writing SM/MES No. in synthetic enamel paint (Black colour) over the same surface where the existing No. was written etc., all as specified and as directed.
46Material and Labour for painting of Exhaust/ Pedestal/ Wall-mounted/ Air-circulator fans of any sweep to obtain even, smooth & glossy finish, with synthetic enamel paint of approved colour by using paint spraying devices after filling cavities with filler after cleaning all dust etc., over fan surfaces; complete including writing SM/MES No. in synthetic enamel paint (colour as approved) over the same surface where the existing No. was written etc., all as specified and as directed.
47Material and Labour for rewinding of fan motor with super enameled copper winding wire of same gauge and weight after cutting and removing the existing burnt/heated up windings, including cleaning of rotor, stator and varnishing, heating and providing fresh insulating materials for Ceiling fan of 1200/1400 mm sweep including dismantling and reassembling.
48All as per Item No.39 herein before but for Exhaust fan 225 to 300mm sweep
49All as per Item No.39 herein before but for Pedestal fan/Aircirculator400 to 600mm sweep
50All as per Item No.39 herein before but for Wall mounted fan 400 sweep
51Supply only ball bearing suitable for ceilingfan of size 1200/1400mm sweep
52Supply only ball bearing suitable for exhaust fan of any size and make
53Replacementof old/unserviceable capacitor of capacity 2.5 µfd for the fans in position as directed.
54Replacementof old/unserviceable capacitor of capacity 4 µfd for the fans in position as directed.
55Supply and fix PVC canopy/Ceiling fan cap with fixing screws etc suitable for ceiling fan 1200/1400mm sweep etc., complete; all as specified and as directed
56Supply and fix ceiling fan blade with fixing accesories etc suitable for ceiling fan 1200/1400mm sweep etc., complete; all as specified and as directed
57Supply and fix exhuast fan blade (metal body)with fixing accessories etc suitable for exhaust fan 300mm sweep etc., complete; all as specified and as directed
58Supply and fix exhuast fan louver (shutter) metal bodywith fixing accessories etc suitable for exhaust fan 300mm sweep etc., complete; all as specified and as directed
59Taking down down rods of ceiling fans (1200/1400 mm sweep) fixed by means of check nut and split pin, "U" clamp bolts, nuts, washers, rubber split pin check nut etc., complete; all as specified and as directed.
60Supply and Fix ceiling fans down rods fabricated out of 15 mm dia GI pipe medium grade duly cutting/ threading/ drilling etc. Suitable for ceiling fans (1200/1400 mm sweep) fixed by means of check nut and split pin, "U" clamp bolts, nuts, washers, rubber split pin check nut etc., complete; all as specified and as directed.
61Taking down existing un serviceable check nut and split pin including "U" clamp bolts, nuts, washers, rubber split pin check nut etc.,complete; from ceiling fan 1200/1400 mm sweep etc., all as specified and as directed.
62Supply and Fix check nut and split pin including "U" clamp bolts, nuts, washers, rubber split pin check nut etc suitable for ceiling fan 1200/1400 mm sweep etc., complete; all as specified and as directed. Note for item No. 30 to 54:- Repairs/ painting shall be carried out only to the fans where SM No. is available over the fans and the contractor shall ensure the same before carrying out such repairs/ painting.
63Supply and Fix ceiling fan hook made out of 40 x 6 mm MS flat iron and 10 dia MS round bar bend to shape for hanging ceiling fans including taking down existing unserviceable fan hook complete; all as specified and as directed.
64Rectifying faults by attending faults of point/sub main wiring complaints (excluding fittings and fixtures) any rating/ make/ model/ type in position including testing of serviceability of point wiring, finding of fault/ defect and repairing, jointing of wires/ cables properly with required jointing materials and making wiring functional etc., complete; all as specified and directed. Note:-(i) The rate quoted is deemed to be inclusive of cost of the required materials like insulation tape etc where required. (ii)Provn of point/sub mainwiring including taking down of the same will be paid under relavent items. (iii) Contractor or his accredited Engineer/ representative shall collect the list of daily complaints from Complaint Cell. (iv) Contractor shall submit the daily list of all rectified/ non-rectified complaints to the Engineer-in-charge at the end of the day"s work on each working day of unit/ AGE"s office.
65Material and Labour for point wiring with cable of PVC FRLS insulated copper multistranded conductor 1.5 sqmm 1100 volts grade in and including medium grade PVC conduit of size 20mm dia and its accessories with ISI marked and fixing arrangements on wall/ ceiling including fixing existing 3mm thick hylam sheet top cover (on wall surfaces ) to existing MS terminal box sunk in wall for housing switches/ sockets/ regulators etc., as required with and including connecting 1.5 sqmm PVC insulated multistranded copper earth continuity conductor to the common earth dolly etc., complete including taking down the existing unserviceable point wiring; all as specified and as directed for one ceiling fan point controlled by one switch 5 Amps, one way.
66All as per Item No.57 above but for One Exhaust fan point controlled by one switch 5 Amps, one way. Note for item No.57 & 58:- Item No.56 will not be measured in the locations where item No. 57/58 needs to be executed.
67Supply and fix, Switch piano flush type 5 Amps, Single Pole one way including connecting to electrical cables and testing on completion; all as specified and as directed.
68Supply and fix fan regulator stepped type electronic flush/switch type, in repairs, suitable for 1200mm /1400 mm sweep fan.
69Supply and fix ceiling rose (polycarbonate, isolated body) of 65 x 50mm three terminals IS marked.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail