Tender For Special Repair To Otm Accommodation No T-154 Of 116 Engr Regt Under Ge (East) Bareilly., bareilly-Uttar Pradesh

Military Engineer Services-MES has published Tender For Special Repair To Otm Accommodation No T-154 Of 116 Engr Regt Under Ge (East) Bareilly.. Submission Date for this Tender is 09-01-2024. Building Work Tenders in bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41198347
Tender For Special Repair To Otm Accommodation No T-154 Of 116 Engr Regt Under Ge (East) Bareilly.
Open Tender
Indian
Uttar Pradesh
bareilly
09-01-2024

Tender Details

Tender For Special Repair To Otm Accommodation No T-154 Of 116 Engr Regt Under Ge ( East ) Bareilly.; 1 Taking Down Cement Plaster Including Racking Out Joints, Hacking For Key & Scrubbing Down With Water Etc Complete All As Specified And Directed. 2 Dismantling, Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) , Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed. 3 Dismantling Of Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Laid, Bedded And Jointed In Any Mortar Etc Complete All As Specified And Directed. 4 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Removecomplete All As Specified And Directed. 5 Demolition Of Cement Concretein Ground Floors And Pavings Not Exceeding 15 Cm Thickness Below Or Above Ground Level Complete All As Specified And Directed By Engineer-In-Charge. 6 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars Etc But Excluding Ashlar Facing Dressed Stone Work And Precast Concrete Articles Complete All As Specified And Directed By Engineer-In-Charge. 7 Demolition Of Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For Complete All As Specified And Directed. 8 Excavating In Trenches N. Exc. 1.5 M Wide, And N.Exc. 1.5 M In Depth For Foundation Etc. N.Exc. 10 Sqm On Plan And N. Exc. 1.5 Mtr In Depth And Getting Out Hard / Dense Soil Complete All As Specified And Directed. 9 Taking Down Chowkats Or Frames Not Exceeding 1.5 Sqm Each With Shutter ( Without Taking Off Shutter From The Frame ) And Removing To Store Complete All As Specified And Directed By Engineer-In-Charge. 10 Taking Down Chowkats Or Frames Exceeding 1.5 Sqm But Not Exceeding 4 Sqm Each With Shutter ( Without Taking Off Shutter From The Frame ) And Removing To Store Complete All As Specified And Directed By Engineer-In-Charge. 11 Taking Down Eaves Gutters And Rainwater Pipes ( Any Size Or Pattern ) , Including All Fittings, Heads, Shoes, Bends, Swan-Necks, Etc., Including Cleaning Or Refixing Or Removal To Store ( Measured Overall As Fixed Along The Centre Line Over Fittings And Accessories ) Complete All As Specified And Directed. 12 M&L 15Mm Thick Rendering In Cement Mortar 1:4 To Brick Masonry Wall Surfaces Or On Other Than Fair Faces Of Brick Wall Surfaces Finished Fair & Even Without Using Extra Cement For Fixing Tiles Etc Complete All As Specified And Directed . 13 M & L 25 Mm Thick Pcc 1:2:4 Type B-1, Using 25 Mm Graded Stone Aggregate As In Floors To Receive Surface Of Tiles Complete All As Specified And Directed. 14 M&L Providing Non- Skid Glazed Ceramic Tiles Coloured 7-8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.06 Sqm But N Exc 0.11 Sqm, In Floor Etc Set And Joited With Neat Cement Slurry And Pointed In Coloured Cement To Match Coloured Tiles Including 15 Mm Thick Cement Screed Bed In Cm 1:6 Complete All As Specified And As Directed. Note : Engr-In-Charge Will Select Sample From Latest Catalouge. 15 M & L 9 To 10 Mm Thick Glazed Coloured Ceramic Tiles ( Square / Rectangular ) With Border Of Size 300X600mm, As In Vertical Surfaces Such As Skirting Or Dado Including 10 Mm Thick Renderingin Cm Mortar 1:4 Set And Joited With Neat Cement Slurry And Pointed In Coloured Cement Incluto Matchcoloured Tiles Complete All As Specified And As Directed. Note : Engr-In-Charge Will Select Sample From Latest Catalouge. 16 M&L Machine Cut Kota Stone Slab Flooring 20-25 Mm Thick Over And Including 20 Mm Thick Screed Bed Laid In Cm 1:6 And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Mirror Polishing And Treating The Surface Incl Complete All As Spd And Directed. 17 M&L Machine Cut Kota Stone 20-25 Mm Thick In Riser Of Steps, Skirting, Dado And Pillar Over And Including 20 Mm Thick Screed Bed Laid In Cm 1:6 And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabcomplete All As Spd And Directed. 18 M&L Providing Edge Moulding To 20-25 Mm Thick Stone Of Counters Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc Complete All As Specified And Directed. 19 M&L 18-20 Mm Thickgraniteof Black Colour ( Table Rubbed And Polished ) Inwin Dow-Cills, Cooking Plat Forms And Like In Cement Mortar ( 1:4 ) Including Point Ing In White Cement ( 1:2 ) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite With Full Round Bull Nosing Edging Complete All As Specified And Directed. 20 M & L For 75Mm Thick Pcc 1:3:6 , Type C-2 Using 40 Mm Graded Stone Aggregate As In Plinth Protection Laid In Slope In 1:30 In Alternative Bays Not Exceeding 3 Mtr In Length.Exposed Surfaces Finished Even And Smooth Without Using Extra Cement Including Raking Out Joints Between Panel To Panel And Panel To Wall And Plugging The Same With Bitumen Mastic Using Bitumen And Sand Mixture In 1:3 Complete All As Specified And Directed . 21 M&L For Reinforced Cement Concrete 1:1.5:3 Type A-1 ( Using 20 Mm Graded Stone Aggregate ) ( Nominal Mix ) As In Slabs Supported On Wall , Landing, Balconies , Shelves And Like Including Bonding Agent Complete All As Specified And Directed ( Reinforcement To Be Measured &Paid Under Respective Items ) 22 M&L Form Work To Chajja, Slab , Weather Shade, Troughs And Similar Items Includingedges For Rough Finished Surfaces Of Concrete Flat, Complete All As Specified And Directed. 23 M&L Form Work To Edges Of Concrete Flats, Treads, Breaks In Floors Window Cill, Concrete Railing Opening In Conc Wall , Floor And Roof N.Exc 20Cm Wide And Sides Of Rcc / Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exc 10 Cm But N.Exc 20Cm Wide For Rough Finished Surfaces Of Concrete, Complete All As Specified And Directed. 24 S&F Mild Steel Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And Directed. 25 M&L Pcc 1:5:10 Type E-2 ( 40 Mm Graded Stone Aggregate ) As Sunken Base Of Floor Fillings Complete All As Spd As Directed. 26 S&F 32 Mm Dia Gi Pipe , Medium Grade As In Spout Pipe In Suken Floor Complete All As Spd And Directed. 27 M&L For Brick Work With Fly Ash Bricks, Straight Or Curved On Plan Exc. 6 M Mean Radius, Built In Cm ( 1:6 ) Complete All As Spd And Directed 28 M&L Rendering 15 Mm Thick In Cm 1:6 On Brick Masonry Surfaces Or On Other Than Fair Faces Of Brick Masonry Finished Even And Smooth Witout Using Extra Cement Complete All As Specified And Directed. 29 M&L 15Mm Thick Rendering In Cement Mortar 1:4 To Brickmasonry Wall Surfaces Or On Other Than Fair Faces Of Brick Masonaryfinishedeven And Smooth Without Using Extra Cement With Using Water Proofing Liquid @ 0.15 Ltr Per Bag Of Cement Complete All As Specified And Directed. ( Note : Cost Of Water Proofing Liquid Deemed To Be Included In Qouted Rate Of Itme ) 30 M&L Rendering 10 Mm Thick In Cm 1:4As On Concerete Surface On Ceilings Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 31 M&L For Applying Cement Slurry Over Existing Roof Surface @ 3 Kg / Sqm Incl Mix With Water Proofing Liquid @0.15 Ltr Per 50 Kg Cement Bags As Per Manufactureres Instructions Complete All As Specified And Directed. 32 M&L For Pcc ( 1:2:4 ) Type B-0 Using 12.5 Mm Graded Stone Aggregrate Laid Over Roof Slab After Applying Cement Slurry For Filling Undulationations Finished Even And Smooth Without Using Extra Cementcomplete All As Specified And Directed. 33 M&L Screed Bed Or Bedding Layer Of Mortar, 15 Mm Thick, In Cement Mortar 1:4, Over Rcc Roof Slabs For Laying Water Proofing Treatment Mixed With Using Water Proofing Liquid @ 150 Ml Per Bag Of Cement Complete All As Specified And Directed. ( Note : Cost Of Water Proofing Liquid Deemed To Be Included In Qouted Rate Of Itme ) 34 Supply And Fix App Based Polymeric Water Proofing Membrane, Minimum 3Mm Thick And Weighing Above 3.0 Kg / Sqm Tochschield Membrane / Equilvalent With Rich Bitumen And Select Polymers Blended To Obtain Excellent Heat Resistant& Cold Resistant , Black Finish Reinforced With Non-Wovenpolyester Matt, With A Thermo Fusable Finish Laid Over Compatible Bitumen Primer Torching Overlaps With A Propane Or A Butane Gas Torch, With A Overlap Of 100Mm At The Ends And Sealing Including Applying A Coat Of Cold Emulsion Bituminous Primer All As Per Manufacturer’S Instructions Completed Including Removal Of Existing Treatment All As Specified And As Directed. Note: ( I ) Coved Fillets In Pcc ( 1:2:4 ) Type B-0 Using 12.5Mm Graded Stone Aggregate, Of Radius 75Mm Shall Be Provided At The Junction Of Roof And Parapet Wall / Mumty / Chimney / Other Vertical Surfaces And Thereafter Surface Painted With Hot Paving Bitumen Of Grade 85 / 25 Confirming To Is-73, Applied@1.20 Kg / Sqm Over A Coat Of Bituminous Primer Confirming To Is-3384 Applied @ 0.40 Kg / Sqm ( Ii ) Polymeric Membrane Shall Be Taken To A Height Of 45Cm ( Minimum ) And Then Inserted Inside The Groove Of Parapet Wall Of Brick Masonry And Shall Be Finished By A Membrane Flushing. ( Iii ) The Waterproofing Treatment Shall Be Got Carried Out By The Manufacturer Or Their Authorized Applicators. ( Iv ) In Case Of Stone Masonry Parapet Wall Etc A Groove Of Size 25Mmx25mm ( Minimuim ) Shall Be Made In Coved Fillet At The Junction Of Roof And Parapet Wall / Mumty Chimny / Other Vertical Surfaces And Polimeric Membrane Insterted In Groove And Sealed With Paving Bitumen ( V ) Exposed Surfaces Of App Membrane Shall Be Applied With One Coat Of Bituminous Aluminium Paint @ 150 Ml / Sqm. ( Vi ) Above Aspects Are Deemed To Be Included In Quoted Rate. 35 M & L For Wpt In Sunken Floors As Described Here Under:- Sunken Floor And Sides Up To Finished Floor Level Shall Be Plastered With 15 Mm Thick Cement Plaster In Cm 1:4 Mixed With Water Proofing Liquid @ 150 Ml Per Bag Of Cement . ( Ii ) Preparing Plastered Surfaces And Providing App Polymeric Water Proofing Membrane, Minimum 4Mm Thick And Weighing Above 4.0 Kg / Sqm Ofmembrane With Rich Bitumen And Select Polymers Blended Together To Obtain Excellent Heat Resistance & Cold Resistant Chemicals As Approved By Ge, Black Finish Reinforced With Non-Woven Polyester Matt, With A Thermo Fusable Finish Laid Over Compatible Bitumen Primerat The Rate Of 0.40 Kg / Sqm Torching Overlaps With A Propane Or A Butane Gas Torch, With A Overlap Of 75Mm At The Sides And 100Mm At The Ends And Sealing Including Applying A Coat Of Cold Emulsion Bituminous Primer All As Per ManufacturerS Instructionsincluding Preparation Of Surface By Removing The Existing Treatment, Complete All As Specified An As Directednote :- ( I ) Polymeric Membrane Shall Belaid In Sunken Floor And On Sides Up To Finished Floor Level. ( Ii ) The Waterproofing Treatment Shall Be Got Carried Out By The Manufacturer Or Their Authorised Applicators. ( Iii ) Above Aspects Are Deemed To Be Included In Quoted Rate. ( Iv ) Supply Only Water Proofing Liquid Shall Be Measured And Paid Seperately 36 S&F Pressed Steel Frames 125X60 Mm For Doors With One Or More Rebates Including Necessary Fixing Lugs , Hinges, Lock Strike Plate Etc Complete All As Specified And Directed. 37 S&F 30 Mm Plain, Framed, Panelled Shutters ( Any Number Of Panels ) 2Nd Class Hw With Panels Of Timber Flat On Both Sides ( Feather Edged ) , Or Of Veenered Particle Board Medium Density , Wood Particle Board With Comercial Face Veeners Complete All As Specified And Directed. 38 S&F 30Mm Thick Factory Made Glazed And Skeleton Door Shutters Open Rebated Of Second Class Hard Wood Rail And Styles ( Hollock ) , Prepared To Receive Glass / Gauge Etc Without Sash Bars, Edges Of Framing Plain Cham-Fered Or Rounded, Mitred And Rebated Sash Bars, Any Numbers The Size Of Rails & Style As Specified In Ssr Part-I ( 2009 ) Section 8 And As Per Is-1003 ( Part-I ) Kiln Seasoned As Per Is-1141 And Chemically Pressure Treated As Per Is-401 Complete All As Specified And Directed By Engineer-In-Charge. ( Note :- S & F Glass / Gauge Shall Be Measured And Paid For Separately ) 39 S&F 150 Mm Long Floor Door Stopper Ofaluminium Alloy Body And Tongue With Hard Drawn Steel Spring. Fixed In Floor Complete All As Spd And Directed. 40 S&F Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Thick Single Side Prelam Pvc Sheet Used Instead Of Plain Colour Pvc Sheet , Suppling & Fixing In Opening As Per Specification & Drawing. 41 S&F 30 Mm Thick Factory Made Both Side Prelam Pvc Sheet Used Instead Of Plain Colour Pvc Sheet. Stile And Rails Feathered At Edges Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails, M.S. Frame Shall Be Covered With Heat Moulded Palin Colour Pvc `C Channel Heaving Apanelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S Frame Wedded / Sealed To The Stiles, & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing. 42 S&F Mild Steel Window Grills Box Typeframed Work As In Window Guard Bars, Grills Or Forged Into Spikes, Framed Balusters, Walkway Railing And Similar Work Including Welding Complete Fe-290 Grade E-165 All As Specified And Directed. 43 S&F Steel Windows With Pressed Steel Frame ( Size 95X45x1.25 Mm ) Side Hung Shutter Including Box Type Hinges With Steel Handle , And Steel Peg Steel Complete With Glazed Openable Shutter With Glazing Bar ( Open Out Side ) And Wire Gauzed Openable Shutter Without Glazed Bar ( Open In Side ) Dovetailed Or Welded Complete All As Spd And Directed And All As Per Drg No Td / 088 Dt 07 Jun 2002 Note:- ( I ) Two Shutter Ie Wire Gauged And Glazed Shall Be Fixed In One Composite Frame And Both Shutter Shall Be Measured As One Unit ( Ii ) Rate For Filling Of Pcc In Frame Deemed To Be Included In Quoted Rate ( Iii0 Ms Grill Shall Be Measured And Paid Seprately Under Relevant Item Of Schedule 44 S&F Steel Ventilators Fixed Type , With Glazing Bars Complete Welded Including One Shop Coat Of Red Oxide Zinc Chromate Primer Complete All As Specified And Directed By Engineer-Incharge ( Note:- Glass Shall Be Measured And Paid Seprately ) 45 M&L For 3Mm Thick Sheet Glass Ordinary Quality And Glazing With Oil Putty In Squares Not Exc. 0.5 Sqm In Each Pane Complete All As Spd Directed 46 M&L Hacking Out Old Broken Glass ( Any Thickness, Size, Quality Or Description ) From Wooden Frames And Fixing 3 Mm Thick Sheet Glass Ordinary Quality And Glazing With Oil Putty In Squares Not Exc. 0.5 Sqm In Each Pane Complete All As Spd Directed 47 S&F Galvanised Steel Wire Cloth , 0.56 Mm Nominal Dia Of Wire And Average With Of Aperture 1.18 Mm And Fixed With Galvanised Steel Wire Staples Complete All As Specified And Directed By Engineer-In Charge 48 S&F 300 Mm Long Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section And Fixed Complete All As Specified And Directed. 49 S&F150 Mm Thick Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section And Fixed Complete All As Specified And Directed. 50 S&F 150Mm Size Aluminium Handles, Cast Type Anodised Completed All As Specified And Directed. 51 S&F 100 Mm Size Butt Hinges Medium Weight Colled Rolled Mild Steel Complete All As Specified And Directed By Engineer-In-Charge. 52 S&F 300Mm Size Ordinary Mild Steel , Rat Tailed Rod Pattern Spring Including Roller And Roller Platewelded To Mild Steel Frame.Fixed In Repaircomplete All As Specified And Directed. 53 S&F 300 Mm Long Aluminiumsliding Door Bolts Plate Type With Bright Bolt Not Less Than 16 Mm Dia With And Including A Minimum Of 6 Bolts And Nuts, 04 Nos On Bolt Plate And 02 Nos On Staple Plate And Fix Complete All As Specified And Directed. 54 S&F Rotational Moulded Polethylene Water Tank Of 1000 Ltrs Capacity, Isi Marked, White Coloured ( Cylindrical Vertical With Closed Top With Suitable Size Ofm S Tasla With Suitable Locking System ) Hoistedand Fixed In Position All As Pacific Ssr Part- I Including Dismantling Ofexisting Water Tanks Capacityn Exc 1000 Ltr Complete All As Specified And Directed. 55 S&F 20Mm Bore Ball Brass Valve High Pressure With Polythene Float And Fly Nut Complete, Screwed For Iron Pipe Or For Brass Ferrule And Fixed Complete All As Specified And Directed. 56 S&F Gi Tube 15 Mm Dia Medium Grade With All Fittingsand Fixed To Wall, Ceiling Or Laid In Floors Including Taking Down Existing Gi Tubing 15 Mm Dia & Connections Complete All As Specified And Directed. 57 S&F Gi Tube 20 Mm Dia Medium Grade With All Fittingsand Fixed To Wall, Ceiling Or Laid In Floors Including Taking Down Existing Gi Tubing 20 Mm Dia & Connections Complete All As Specified And Directed. 58 S&F In Repairs Brass Chromium Platedwall Mixer 3 In 1, 15Mm For Mixing Hot & Cold Water Screwd Down Three Joints To Steel Pipes Or Unions And Plugging And Screwed To Walls Complete All As Specified And As Directed. 59 S & F In Repair Fancy Type 125Mm Size Square Brass Cp Shower Rose Complete All As Specified And As Directed. 60 S&F In Repairs 15 Mm Dia Bib Tap Fancy Type Chromium Plated With Flange Quarter Turn Complete All As Specified As Directed. 61 S&F In Repair Fancy Type Chromium Plated Brass Two Way Bib Cocksuitable For 15Mm Bore Pipe Complete All As Specified And Directed. 62 S&F In Repair Stainless Steel Of Grade Tubulartowel Ringincluding Apair Ofcp Brass Bracket Complete All As Specified And As Directed. 63 S&F In Repairs 15Mm Bore Pvc Connections, With Ptmt Nuts Of Length 450Mm Complete All As Specified And Directed. 64 S&F In Repair Fancy Type Brass Chromium Plated Soap Dish Of 160X160x90 Mm Complete All As Specified And As Directed. 65 S&F In Repair Fancy Type Chromium Plated Brass Angle Valve Type Suitable For 15Mm Bore Pipe Complete All As Specified And As Directed. 66 S & F In Repair Fancy Type Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12 Cm Wide With Cp Brackrt Gaurd And Railling 60 Cm Long Complete All As Specified And As Directed. 67 S&F 20Mm Dia Gun-Metal, Globe Or Gate Valves, With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixed Complete All As Specified And As Directed. 68 S&F In Repair 15 Mm Dia Fancy Type Stop Cock , Chromium Plated With Long Shank And Cup ( Conncelaed Type ) For Iron Pipe Or For Unions And Fixed Complete All As Specified And As Directed. 69 S&F In Repair Vitreous China Squatting Pan Of Orrissa Pattern Long Pan Size580 X 440 Mm White With POr S Trap Size100 Mm Dia Front Or Back Inlet And Integral Foot Rest Any Pattern ( Excluding Flushing Cistern And Flush Pipe ) Water Closet Squatt Pattern Complete Including Provn Of Lime Concrete Bedding Complete All As Specified And As Directed. 70 S&F In Repair Pvc Low Level Flushing Cistern 10 Litres, Valveless, Syphonic Action Type, Flushing Cistern, Low Level, White, With Inlet, Ball Valve, Float And Handle Including Brackets, Flushing Pipe Complete All As Specified And Directed. 71 S&F Vitreous China Counter Top Oval Type Coloured Wash Basin Suitable Size Including Swan Neck Pillar Taps With Bottle Trap But Including Waste Pipe Fixing On Counter With Stainless Steel Brackets Complete All As Specified And As Directed. 72 S&F Health Faucet ( Abs Body ) Mild Steel Chromium Plated Suitable For 15 Mm Dia Pipe With 1.25 Metre Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete In All Respect Complete All As Specified And As Directed. 73 S&F In Repairpvc ( Swr ) Multifloor Trap With Grating Including Jointing With Solvent Cement Floor Trap 100 Mm Dia Outlet Plain With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete 1:2:4, Typeb-1 Complete All As Specified And Directed. 74 S&Fpvc ( Swr ) 75 Mm Bore Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Wall And Floor With Neceassary Fitting Complete All As Specified And Directed. 75 S&Fpvc ( Swr ) 110Mm Bore Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Wall And Floor With Neceassary Fittingcomplete All As Specified And Directed. 76 S&F Pvc ( Swr ) 110Mm Bore Bends Anyradiuscomplete All As Specified And Directed. 77 S&F Pvc ( Swr ) 75Mm Bore Bends Any Radiuscomplete All As Specified And Directed. 78 S&F Pvc ( Swr ) 75 Mm Bore Junction Single ( Single T ) Equal Or Unequal With Access Doorcomplete All As Specified And Directed. 79 S&F Pvc ( Swr ) 110 Mm Bore Junction Single ( Single T ) Equal Or Unequal With Access Doorcomplete All As Specified And Directed. 80 S&F Designed Looking Mirror Of Any Size Of Selected Quality 6Mm Thick Glass, Mounted On Fixed To Wall With Cpplugs With Chromium Plated Brass Screws And Cup Washer Scomplete All As Specified And As Directed. 81 S&F In Repair20 Mm Dia Stainless Steel 1.0 Mm Thick Fancy Typedroppery Rod With Decorative Design Matching Brackets As Approved And Knobs ( Lattu ) Or End Bracket As Required Incl Fitting With 80 Mm Long Ss Screw With 75 Mm Long Wooden Gitty Of Appropriate C / S In Each End & Intermediate Support Complete All As Specified And As Directed. 82 S&F Rolled Sections As In Main And Cross Beams, Hip And Jack Rafters; Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Confirming Fe-410-W ( Gde E-250 ) Quality-A Complete All As Spd And Directed . 83 S&F Pre-Coated Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws As Specified. 84 M & L For Cutting Chases, Pinning In, Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Chajja ( Up To Iind Floor ) Etc Making Good, Cutting Exc 10Cm And Not Exc 40Cm Girth In Stone Concrete Block Or Slab Walls Complete All As Specified And As Directed. 85 Dismantling Of Concrete By Chiseling From Rcc Members Like Column , Beam, Parapet Facia, Chajja, Ceiling, Etc Exposingthe Reinforcement Without Disturbing The Reinforcement Free From Rust By Sand Blasting / Using Chemical , Apply A Coat Of Rustolin To Remove Rust And Acralic Polymer On Old Rusted Reinforcement Proving At Places Addl Reinforcement Welding With Existing Reinforcement As Directed Wherever Required Binding Rcc 50 Mmx50 Mm ( 10 Mm Gauge Welded Mesh ) & Tack , Securing With Clips / Blinding Wire, Welding & Provision Guniting Pressure 2.2 To 2.5 Kg / Sqm With Admixer 1 Cement 3.5 Of Sand Of Thickness 25 To 40 Mm Including Stripping Floating With Wooden Strippers For Proper Dimension Control Neccssary Form Work & Scaffolding Up To Three Storey And Including Height Of Head Room Complete Surface Of Guniting To Be Finished Fair With 10 Mm Thick Plaster In Cement Mortar 1:4 With Water Proofing Compound @3% By Weight Of Cement And Construction Fibre As Per Manufacturer Instruction Cleaning & Removing Of Waste Meterial Etc As Dirply Two Coat Of Water Proofing Liquid At Interval Of 8 Hours Cure For Thesurfaces Complete All As Specified And As Directed. 86 S&F 0.71 Mm Thick Plain Aluminium Sheeting Alloy 31000 H4 In Stepped Flashing ( Measured As The Minimum Rectangle From Which The Pieces Can Be Cut ) Complete All As Specified And Directed. 87 M&L Preparation New Or Previously Untreated Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over And Including One Coatof Red Oxide Zinc Chrome Primer Complete All As Specified Anddirected. 88 M&L For Preparation Of New Or Previously Untreated Wooden Or Wood Based Surfaces Of Any Description Not Otherwise Described Over 10 Cm Width Or Girth And Applying Two Coat Of Synthetic Enamel Paint Over And Including One Coatof Pink Primer Complete All As Specified And Directed. 89 M&L For Preparation Of Old Painted Wooden Or Wood Based Surfaces Of Any Description N.Exc 10 Cm In Width Or Girth When Unconnected With Other Painting Or When Painted In A Diferenttint And Applying One Coat Of Synthetic Enamel Paint Over And Including One Coat Of Pink Primer Complete All As Specified And Directed. 90 M&L For Complete Removal Of Existing Treatment On Wall By Scrapping With Mechanical Sander ( Having Mechanical Vaccum Mechanism ) With Sanding Pad Of Appropriate Grit To Make Surface Clean , Free From Dust , Loose Paint Etcby Skilled Labour And Applying Two Coat Obd On Wall With Airless Electric Sprayers Over A Coat Of Primer Applied Using Airless Electric Sprayer Over Two Coat Of Wall Care Putty Of 1Mm Thickness Complete All As Specified And Directed. Note:-Application To Be Done Through Authorised Dealer. 91 M&L For Applying Of Two Coat Obd On Newly Plastered Surface Of Wall With Airless Electric Sprayers Over A Coat Of Primer Applied Using Airless Electric Sprayers Over Two Coat Of Wall Care Putty Of 1 Mm Thickness Prepared And Sanded With Electrically Operated Sanding Machinecomplete All As Spd And Directed .Application To Be Done Through Authorized Applicator Complete All As Specified And As Directed. 92 M&L For Preparation Of Newly Plastered Surface Of Walls And Applying Two Coats Of Dust Resistant And Anti Algal Weather Proof Exterior Emulsion Paints Over A One Coat Of Wall Care Putty Complete All As Specified And Directed. 93 M&L For Complete Removal Of Existing Treatment Onsurfaces Of Walls Including Cleaning The Surface Throughly By Using Wire Brushes And Removing Use Materials From The Surface And Applying Two Coats Of Dust Resistant And Anti Algal Weather Proof Exterior Emulsion Paints Over A One Coat Of Wall Care Putty Complete All As Specified And Directed. 94 M&L For Preparing Newly Plastered Surfaces And Applying Three Coats Of White Wash On Ceiling Complete All As Specified And Directed. 95 M&L Complete Removal Of Existing Treatment On Ceiling, Etc Including Cleaning Of Any Mortar Drops , Fungus Efflorescent Salts Etc And Prepration Of Old Plastered Surface And Applying Two Coat Of White Wash Complete All As Specified And As Directed. 96 M & L For Cutting Existing Steel Tubing Upto 50Mm Dia And Inserting Suitable Gi Fittings Etc For Alterations / Addition The Branch Connection Complete. 97 Supply & Layinggipipemedium Grade Including Fittings 25Mm Dia Including Taking Downunsv Serviceable Gi Pipe Of Any Size Complete All As Specified And As Directed. 98 Supply & Layinggipipemedium Grade Including Fittings 20Mm Dia Including Taking Downunsv Serviceable Gi Pipe Of Any Size Complete All As Specified And As Directed. 99 Supply & Layinggipipemedium Grade Including Fittings15 Mm Dia Including Taking Downunsv Serviceable Gi Pipe Of Any Size Complete All As Specified And As Directed. 100 Supply & Fix In Replacementgun Metal Gate Valve With Iron Wheel Head, Screwed Both Ends For Pipe 25 Mm Dia Complete All As Specified And As Directed. 101 Supply & Fix In Replacement Gun Metal Gate Valve With Iron Wheel Head, Screwed Both Ends For Pipe 20 Mm Dia Complete All As Specified And As Directed. 102 S&F Stop Bib Tap Opper Alloy With High Pressurewith Crutch Handle Fancy Typescrewedboth Ends For Rion Pipe Or For Union And Fixed To 15 Mm Dia Bore Gi Medium Grade Pipe Complete All As Specified And As Directed. 103 Taking Down Copper / Aluminum Point Wiring Complete Including Fixture And Fitting Such As Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings, Holders Etc And Removing The Items From Site To Store For Taking Credit ( Credit For Above Items Should Be Made As Per Conditions Separately ) And Making Good Disturbed Surfaces To Match With The Existing Surfaces Of Walls, Floors Etc Complete All As Specified And Directed. 104 Taking Down Main Switch / Mcb Dbs Including Mccbs Etc Of Any Size And Removing The Items From Site To Store For Taking Credit ( Credit For Above Items Should Be Made As Per Conditions Separately ) And Making Good Disturbed Surfaces To Match With The Existing Surfaces Of Wall, Floors Etc Complete All As Specified And Directed. 105 Taking Down Ceiling / Exhaust Fan And Disconnecting, Removing To Store For Keeping In Safe Custodyfor Ber Board Or Rehanging Etc After Some Minor Repair Complete All As Specified And Directed. 106 Taking Down Electric Geyserand Disconnecting , Removing To Store Forkeepingin Safe Custodyfor Refixingetc Completeall As Specified And Dircted And Refixing The Same As Its Original Postion. 107 Taking Down Submainwiring / Service Cableincluding Earth Wire And Removing From Site To Store For Taking Credit ( Credit For Above Items Should Be Made As Per Conditions Separately ) And Making Good Disturbed Surfaces To Match With The Existing Surfaces Of Walls, Floorscomplete All As Specified And Directed. 108 M & L For Point Wiring With 1.5 Sqmm Cable Pvc Unsheathed And Insulated Copper Multistranded Conductor Frls1100 Volts Grade Cable ( Red Colour Cable To Be Used For Live Connection And Black Colour Cable To Be Used For Neutral Connection ) Controlled By One Way Switch Drown Through And Including Pvc Concealed Conduit With All Accessories Including 1.5 Sqmm Copper Multistrand Conductor Frls1100 Volts Grade Unsheathed Pvc Insulated ( Green Colour ) Continuity Earth Wire Connected To Common Earth Dolly And Sunk Cast Pressed Steel Terminal Box Made Out Of Ms Sheet 1.25 Mm Thick For Mounting Of Fittings Like Switch , Socket And Fan Regulator With 3 Mm Thick Hylum Laminated Sheet Cover Incl Cutting Chases Pinning In, For Concealed Conduit Wiring And Making Goods Of Disturbed Surface Not Exc 15 Cm Girth Complete All As Specified And As Directed Following For One Light Point / Fan / Exh Fan / Bell Point Controlled By One Way Switch. 109 One Light / Fan Point / Exhaust Fan Controlled By One Switch. 110 One 3 Pin Socket Outlet 5 Amp On Same Board 111 One 3-Pin Socket Outlet 5 Amp On Independent Board. 112 One Light Point Controlled By Two Way Switch 113 S&F Switch Piano Flush Type Single Pole One Way 5 Amps Complete All As Specified And As Directed. 114 S&F Switch Piano Flush Type Single Pole One Way 15 Amps Complete All As Specified And As Directed. 115 S&F Switch Piano Flush Type Single Pole Two Way 15 Amps Complete All As Specified And As Directed. 116 S&F Socket Outlet 2 In 1, 3 Pin 5 Amp Flush Type Complete All As Specified And As Directed. 117 S&F Socket Outlet 2 In 1, 3 Pin 5 Amp And 15 Amps Complete All As Specified And As Directed. 118 S&F Lamp Holder, Pvc / Polycarbonate Type With Back Plate For Batten Fittings Complete All As Specified And As Directed. 119 S&F Rechageable Lamp Led 15 Watt 230 Volt Complete All As Specified And As Directed. 120 S&F Ceiling Rose, 3Terminals, Pvc Polycarbonate Isolated Body Complete All As Specified And As Directed. 121 S&F Stepped Type Electronic Fan Regulator Flush Type On The Existing Phenolic Laminated Sheet Etc. As Requried Complete All As Specified And As Directed. 122 S&F In Repairsled Bulk Head Luminairehexafit 10 Watt Ledenvironmental Friendly, Ultra Modern , Energysaving , Surfacemounted , Decorativehexagonalbulk Headback Lit Led Luminariescomprisingof High Brrightnessled Complete All As Specified & As Directed. 123 S&F In Repairssurface And Wall Mountedledtube Lightbattenwith Polycarbonatehousing And Integtatedeletrinic Driverfittings 20 Watt ( T-8 ) , 4Including Connecting Up With 3 Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified & As Directed. 124 S&F In Repairssurface And Wall Mountedledtube Lightbattenwith Polycarbonatehousing And Integtatedeletrinic Driverfittings 10 Watt ( T-8 ) , 2Including Connecting Up With 3 Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified & As Directed. 125 S&F In Repairs New Generationled Building Security Light Fitting 35 Watt 230 Volts Ac Out Door Type Energy Saving Andenvrionmental Friendlylong Lifeled Street Light Made Out Ofwith High Pressure Die Cast Aluminium Housing With High Efficiency Led Asc Lighting Source Andlens Embeded Pc Cover Having Bottomopening Seperate Drivercomponentwith Ip 66 Protectionand Impact Resistance Of Ik08 Including Electric Conection Complete All As Specified & Directed. 126 S & F Exhaust Fan Ac Single Phase, Metallic Body , Heavy Duty, 230 / 240 Volts, Of Size 300 Mm Sweep With Louversincluding Making Suitable Sizehole In The Wall For Air Flow And Grouting Of Nuts & Bolts And Washers Including Making Connection With Three Core Copper Cable Of Size Not Less Than 1.5 Sqmm From Ceiling Rose Complete All As Specified & Directed. 127 Hanging Only Geyser Aftercleaning& Making Functional By Replacement Of Thermostat , Nrv , Angle Valve, Heating Element , Inner Tank ( If Required ) , Hot And Cold Pipe 450 Mm Long Braided Hose Required Replacementandconnection Etc. Painting Andremarking The Serial Mesnos Etc Complete Including Electric Connection With Three Core Flexible Pvc Insulated Copper Conductor Multistranded Whitein Clour 2.5 Sqmmcableincluding Plug Topcomplete All As Specified And As Directed. 128 S&F In Repairs Round Shape 10 Watt Recessedmounted Led Down Lighter With White Powder Coated Alu Housing With Integrated Electrinic Driverthd<10% 220 Volts Ac Recessed Type With High Efficiency Pmma Diffuser Soft Glare Free Light Completefor Roof Ceiling Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified & As Approved By Ge. 129 Supply And Fixing Ceiling Fans 1200 Mmsweep Complete With Blades, Down Rod , Electronic Regulator And Accessories, 230 V, 25 Watt To 36 Watt , Minair Delivery 210 Cfm With Service Value 6.00 Bee ( Five Star ) Rated Brushless Direct Currentmotor ( Bldc ) And Markingthe Serialmes Fan Nos Etc Inclding Electric Connectionwith Three Core Flexiblepvcinsulatedcopperconductor Multistrandedcable 1.0 Sqmmcompleteall As Specified And Directed. 130 S & Fgi Bracket Made Out Fromgi Pipe 32 / 25Mm Dia, 1.2 Mtr Long Bend To Shape Including 02 Nos 25X4 Mm Ms Clamps, Nuts, Bolts Washersfixed On Wall & Including Painting Etc Complete All As Specified And As Directed. 131 S&F Sheet Metal Enclousers ( Dbs ) When Mcbs To Be Used 8 Way Double Doorwith 200 Amps Rated Bus Bar Complete All As Specified And As Directed. 132 S&F Sheet Metal Enclousers ( Dbs ) When Mcbs To Be Used 12 Way Double Doorwith 200 Amps Rated Bus Bar Complete All As Specified And As Directed. 133 S&F Sheet Metal Enclousers ( Dbs ) When Mcbs To Be Usedvertical Three Phase And Neutral ( Vtpn ) 6 Way Double Doorwith 200 Amps Rated Bus Bar With Mccb Incommercomplete All As Specified And As Directed. 134 Supply And Fix Mccbs 415V, 16 Ka, 3 Pole 125 -160 Amps Complete All As Specified And As Directed. 135 S&F Mcb Single Phase And Neutral 40-63A, 240Volt C- Curve Complete All As Specified And Directed. 136 S&F Mcb Single Pole 40A, 240Volt B-Curve Complete All As Specified And Directed. 137 S&F Mcbsp 6A-32A, 240Volt B Curve Complete All As Specified And Directed. 138 S&F Single Pole And Neutral Enclosurewith A Two Pin Earth Plug And Socketcomplete With One Sp Mcb 20 Amps Complete All As Specified And As Directed. 139 S&F Sub Main Wiring With 2 Run Frls Pvc Insulated And Unsheathed Multistrandedcopper Condutorof Nominal Cross Section Area 2.5 Sqmm Alongwith One Run Of Frls Pvc Insulated And Unsheathedmultistrandedcopper Conductor Of Nominal Cross Secrtionalarea 2.5 Sqmm As Earthcontuinity Conductordrawnthroughin And Including Pvc Conduit Complete All As Specifiedandas Directed. 140 S&F Sub Main Wiring With 2 Run Frls Pvc Insulated And Unsheathed Multistrandedcopper Condutorof Nominal Cross Section Area 4.0 Sqmm Alongwith One Run Of Frls Pvc Insulated And Unsheathedmultistrandedcopper Conductor Of Nominal Cross Secrtionalarea 4.0 Sqmm As Earthcontuinity Conductordrawnthroughin And Including Pvc Conduit Complete All As Specifiedandas Directed. 141 S&F Sub Main Wiring With 2 Run Frls Pvc Insulated And Unsheathed Multistrandedcopper Condutorof Nominal Cross Section Area 6.0 Sqmm Alongwith One Run Of Frls Pvc Insulated And Unsheathedmultistrandedcopper Conductor Of Nominal Cross Secrtionalarea 6.0 Sqmm As Earthcontuinity Conductordrawnthroughin And Including Pvc Conduit Complete All As Specifiedandas Directed. 142 Excacvation In Trenches Not Exc 1.5 Mtr Wide And N Exc 1.5 Mtr In Depth And Getting Out In Soft / Loose For Laying Cables Complete All As Specified. 143 Returning, Filling In Including Spreading, Levelling, Watering And Well Ramming In Layers N Exc 25 Cm In Soft / Loose Soil Complete All As Specified. 144 Removing Excavated Material N Exc 50 M And Depositing Where Directed At A Level N Exc 1.5 M Above The Starting Point Complete All As Specified And As Directed. 145 Supply & Layingsub Class B Bricks, Well Burnt , Laid Wirdthwise Along The Length Of Cable Laid In Trench Over Sand Cushion Laid For Cable Protection, Complete As Specified And Directed. 146 Material And Labour For River Washedand Sreened, Dry Sand For Filling In Trenchbelow And Aroundthe Under Ground Cable For Cushioning Of Cable Etc, Complete All As Specified. 147 Boring Of Holes Under Road Or Cutting The Road / Path / Pavement / Hard Standing Or Any Other Situation Bymannualmeansfor 25Mm Bore Gi Pipe For Crossing The Cable And Making Good Both The Ends All As Specified And Directed At Site. Note :- Gi Pipeshall Be Measured And Paid Separately Under Respective Item. 148 Supply & Fix Tube40 Mm Borelight Grade Giwith All Fittingsfor Cable Protection For Road Crossing / Culvert / Path / On Wall / Floor / Pole / Across The Road / Path / Culverts Or Laid In Floor Complete All As Specified And As Directed. 149 Supply, Laying And Testing Cable Xlpe Insulated, Screened, Pvc Bedded, Gi Steel Strip Or Wire Armoured, Electric Power Cable ( Heavy Duty ) , 1100Volts With Stranded Aluminium Conductor Of Size 70 Sqmm 3.5 Core Including Taking Downservice Connection / Ug Cable Removing At Site Complete All As Specified And As Directed. 150 M&L For Earthling Complete With Galvanised Steel Earth Plate Electrode 600 Mm X 600 Mm X 6 Mm Thick Buried Directrly In Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Blow Gl With Top Edge Of Earth Plate Not Less Than 1.5 Mtr Below Normal Ground Level, Earth Plate Surrounded From All Sides By 15 Cm Thick Packed Layer Of Vharcoal Dust And Common Salt Filled In Alternate Layers And Electrode Connections By Using Galvanised Earth Lead Wire 4Mm Connected By Means Of Bolts, Nuts, Check Nuts And Washer Of Galvanized Iron Or Steel, Provision Of 40 Mm Dia Gi Pipe Light Grade For Protection Of Gl Earth Strip And 20 Mm Dia Gi Pipe Medium Grade For Watering Arrangement And Pcc ( 1:3:6 ) Type B1 Chamber, Ms Funnel, Wire Mesh, 50 Mm Thick Rcc 1:2:4 Type B1 Earth Pit Cover With 6 Nos, 8 Mm Dia High Strength Deformed Steel Tmt Bars On Both Ways Including Necessary Excavation In Any Type Of Soil, Returning, Filling In, Removal Of Surplus Soil To Distance N Exc 50 Mtr, Provision Of Charcoal And Slat Complete All As Shown In Electrical Plate No 3 Of Schedule Ssr Part-I.Note : ( I ) Cost Of Gi Earth Strip / Gi Earth Wire And Gi Protection Pipe Upto 7.5 Mtr Length Shall Be Deemed To Be Included In The Rate Quoted For This Item. ( Ii ) The Unit Rate Shall Also Includes For Wire Mesh, Funnel, Excavation, Returning Filling, Removing, Pcc Chamber Pit , Rcc Cover Slab With Handle For Lifting , Test Point Etc.

Key Value

Document Fees
INR 500 /-
EMD
INR 99800.0 /-
Tender Value
INR 49.90 Lakhs /-

BOQ Items

NAME OF WORK: Special Repair to OTM Accn No T-154 of 116 Engr Regt Under GE (EAST) BAREILLY.
Sl. No. Item Description
1Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed.
2Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
3Dismantling of stone slabs and tiles of any description or thickness in floors, aprons laid,bedded and jointed in any mortar etc complete all as specified and directed.
4Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to removecomplete all as specified and directed.
5Demolition of cement concretein ground floors and pavings not exceeding 15 cm thickness below or above ground level complete all as specified and directed by Engineer-in-Charge.
6Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
7Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
8Excavating in trenches n. exc. 1.5 m wide, and n.exc. 1.5 m in depth for foundation etc. n.exc. 10 sqm on plan and n. exc. 1.5 mtr in depth and getting out hard/ dense soil complete all as specified and directed.
9Taking down chowkats or frames not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed by Engineer-in-Charge.
10Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed by Engineer-in-Charge.
11Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
12M&L 15mm thick rendering in cement mortar 1:4 to brick masonry wall surfaces or on other than fair faces of brick wall surfaces finished fair & even without using extra cement for fixing tiles etc complete all as specified and directed .
13M & L 25 mm thick PCC 1:2:4 type B-1, using 25 mm graded stone aggregate as in floors to receive surface of tiles complete all as specified and directed.
14M&L providing non- skid glazed ceramic tiles coloured 7-8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but n exc 0.11 sqm, in floor etc set and joited with neat cement slurry and pointed in coloured cement to match coloured tiles including 15 mm thick cement screed bed in CM 1:6 complete all as specified and as directed. Note : Engr-in-Charge will select sample from latest catalouge.
15M & L 9 to 10 mm thick glazed coloured ceramic tiles ( square/ rectangular) with border of size 300x600mm, as in vertical surfaces such as skirting or dado including 10 mm thick renderingin CM mortar 1:4 set and joited with neat cement slurry and pointed in coloured cement incluto matchcoloured tiles complete all as specified and as directed. Note : Engr-in-Charge will select sample from latest catalouge.
16M&L Machine cut kota stone slab flooring 20-25 mm thick over and including 20 mm thick screed bed laid in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing and treating the surface incl complete all as spd and directed.
17M&L Machine cut kota stone 20-25 mm thick in riser of steps, skirting,dado and pillar over and including 20 mm thick screed bed laid in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slabcomplete all as spd and directed.
18M&L Providing edge moulding to 20-25 mm thick stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc complete all as specified and directed.
19M&L 18-20 mm thickGraniteof black colour (table rubbed and polished) inwin dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with full round bull nosing edging complete all as specified and directed.
20M & L for 75mm thick PCC 1:3:6 , type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length.Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed .
21M&L for reinforced cement concrete 1:1.5:3 type A-1 (using 20 mm graded stone aggregate ) ( nominal mix ) as in slabs supported on wall , landing, balconies , shelves and like including bonding agent complete all as specified and directed (reinforcement to be measured &paid under respective items )
22M&L form work to chajja, slab ,weather shade, troughs and similar items includingedges for rough finished surfaces of concrete flat, complete all as specified and directed.
23M&L form work to edges of concrete flats, treads, breaks in floors window cill, concrete railing opening in conc wall , floor and roof n.exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20cm wide for rough finished surfaces of concrete, complete all as specified and directed.
24S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
25M&L PCC 1:5:10 type E-2 (40 mm graded stone aggregate) as sunken base of floor fillings complete all as spd as directed.
26S&F 32 mm dia GI pipe ,medium grade as in spout pipe in suken floor complete all as spd and directed.
27M&L for brick work with fly ash bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as spd and directed
28M&L rendering 15 mm thick in CM 1:6 on brick masonry surfaces or on other than fair faces of brick masonry finished even and smooth witout using extra cement complete all as specified and directed.
29M&L 15mm thick rendering in cement mortar 1:4 to brickmasonry wall surfaces or on other than fair faces of brick masonaryfinishedeven and smooth without using extra cement with using water proofing liquid @ 0.15 Ltr per bag of cement complete all as specified and directed. (Note : Cost of Water proofing liquid deemed to be included in qouted rate of itme)
30M&L rendering 10 mm thick in CM 1:4as on concerete surface on ceilings finished even and smooth without using extra cement complete all as specified and directed.
31M&L for applying cement slurry over existing roof surface @ 3 kg/Sqm incl mix with water proofing liquid @0.15 Ltr per 50 kg cement bags as per manufactureres instructions complete all as specified and directed.
32M&L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregrate laid over roof slab after applying cement slurry for filling undulationations finished even and smooth without using extra cementcomplete all as specified and directed.
33M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, over RCC roof slabs for laying water proofing treatment mixed with using water proofing liquid @ 150 ml per bag of cement complete all as specified and directed. (Note : Cost of Water proofing liquid deemed to be included in qouted rate of itme)
34Supply and fix APP based polymeric water proofing membrane, minimum 3mm thick and weighing above 3.0 Kg/Sqm tochschield membrane/equilvalent with rich bitumen and select polymers blended to obtain excellent heat resistant& cold resistant , black finish reinforced with non-wovenpolyester matt, with a thermo fusable finish laid over compatible bitumen primer torching overlaps with a propane or a butane gas torch, with a overlap of 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions completed including removal of existing treatment all as specified and as directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 85/25 confirming to IS-73, applied@1.20 Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm(ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii)The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv)In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate.
35M & L for WPT in sunken floors as described here under:- Sunken floor and sides up to finished floor level shall be plastered with 15 mm thick cement plaster in CM 1:4 mixed with water proofing liquid @ 150 ml per bag of cement . (ii) Preparing plastered surfaces and providing APP polymeric water proofing membrane, minimum 4mm thick and weighing above 4.0 Kg/Sqm ofmembrane with rich bitumen and select polymers blended together to obtain excellent heat resistance & cold resistant chemicals as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over compatible bitumen primerat the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer"s instructionsincluding preparation of surface by removing the existing treatment, complete all as specified an as directedNote :-(i) Polymeric membrane shall belaid in sunken floor and on sides up to finished floor level.(ii)The waterproofing treatment shall be got carried out by the manufacturer or their authorised applicators. (iii)Above aspects are deemed to be included in quoted rate. (iv) Supply only water proofing liquid shall be measured and paid seperately
36S&F Pressed steel frames 125x60 mm for doors with one or more rebates including necessary fixing lugs ,hinges,lock strike plate etc complete all as specified and directed.
37S&F 30 mm Plain,framed,panelled shutters(any number of panels) 2nd class HW with panels of timber flat on both sides (feather edged),or of veenered particle board medium density ,wood particle board with comercial face veeners complete all as specified and directed.
38S&F 30mm thick factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc without sash bars, edges of framing plain cham-fered or rounded, mitred and rebated sash bars, any numbers The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed by Engineer-in-Charge. (Note :- S & F Glass/gauge shall be measured and paid for separately)
39S&F 150 mm long Floor door stopper ofaluminium alloy body and tongue with hard drawn steel spring. fixed in floor complete all as spd and directed.
40S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick single side prelam PVC sheet used instead of Plain colour PVC sheet , suppling & fixing in opening as per specification & drawing.
41S&F 30 mm thick factory made both side Prelam PVC sheet used instead of Plain colour PVC sheet. Stile and rails feathered at edges consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C" channel heaving aPanelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
42S&F mild steel window grills box typeframed work as in window guard bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding complete FE-290 grade E-165 all as specified and directed.
43S&F Steel windows with pressed steel frame (size 95x45x1.25 mm) side hung shutter including box type hinges with steel handle ,and steel peg steel complete with glazed openable shutter with glazing bar (open out side) and wire gauzed openable shutter without glazed bar (open in side) dovetailed or welded complete all as spd and directed and all as per drg no TD/088 dt 07 Jun 2002 Note:-(i) Two shutter ie wire gauged and glazed shall be fixed in one composite frame and both shutter shall be measured as one unit (ii) Rate for filling of PCC in frame deemed to be included in quoted rate (iii0 MS grill shall be measured and paid seprately under relevant item of schedule
44S&F steel ventilators fixed type ,with glazing bars complete welded including one shop coat of Red oxide Zinc chromate primer complete all as specified and directed by Engineer-inCharge (Note:- Glass shall be measured and paid seprately)
45M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 Sqm in each pane complete all as spd directed
46M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames and fixing 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 sqm in each pane complete all as spd directed
47S&F galvanised steel wire cloth ,0.56 mm nominal dia of wire and average with of aperture 1.18 mm and fixed with galvanised steel wire staples complete all as specified and directed by Engineer-in charge
48S&F 300 mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
49S&F150 mm thick Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
50S&F 150mm size aluminium handles, cast type anodised completed all as specified and directed.
51S&F 100 mm size butt hinges medium weight colled rolled mild steel complete all as specified and directed by Engineer-in-Charge.
52S&F 300mm size ordinary mild steel , rat tailed rod pattern spring including roller and roller platewelded to mild steel frame.fixed in repaircomplete all as specified and directed.
53S&F 300 mm long aluminiumsliding door bolts plate type with bright bolt not less than 16 mm dia with and including a minimum of 6 bolts and nuts, 04 Nos on bolt plate and 02 Nos on staple plate and fix complete all as specified and directed.
54S&F rotational moulded polethylene water tank of 1000 ltrs capacity, ISI Marked, white coloured (cylindrical vertical with closed top with suitable size ofM S Tasla with suitable locking system) hoistedand fixed in position all as pacific SSR Part- I including dismantling ofexisting water tanks capacityn exc 1000 ltr complete all as specified and directed.
55S&F 20mm bore ball brass valve high pressure with polythene float and fly nut complete, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
56S&F GI tube 15 mm dia medium grade with all fittingsand fixed to wall, ceiling or laid in floors including taking down existing GI tubing 15 mm dia & connections complete all as specified and directed.
57S&F GI tube 20 mm dia medium grade with all fittingsand fixed to wall, ceiling or laid in floors including taking down existing GI tubing 20 mm dia & connections complete all as specified and directed.
58S&F in repairs brass chromium platedwall mixer 3 in 1, 15mm for mixing hot & cold water screwd down three joints to steel pipes or unions and plugging and screwed to walls complete all as specified and as directed.
59S & F in repair fancy type 125mm size square brass CP shower rose complete all as specified and as directed.
60S&F in repairs 15 mm dia bib tap fancy type chromium plated with flange quarter turn complete all as specified as directed.
61S&F in repair fancy type chromium plated brass two way bib cocksuitable for 15mm bore pipe complete all as specified and directed.
62S&F in repair stainless steel of grade tubulartowel ringincluding apair ofCP brass bracket complete all as specified and as directed.
63S&F in repairs 15mm bore PVC connections, with PTMT nuts of length 450mm complete all as specified and directed.
64S&F in repair fancy type brass chromium plated soap dish of 160x160x90 mm complete all as specified and as directed.
65S&F in repair fancy type chromium plated brass angle valve type suitable for 15mm bore pipe complete all as specified and as directed.
66S & F in repair fancy type sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with CP brackrt gaurd and railling 60 cm long complete all as specified and as directed.
67S&F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
68S&F in repair 15 mm dia fancy type stop cock , chromium plated with long shank and cup (conncelaed type)for iron pipe or for unions and fixed complete all as specified and as directed.
69S&F in repair vitreous china squatting pan of orrissa pattern long pan size580 x 440 mm white with "P"or "S" trap size100 mm dia front or back inlet and integral foot rest any pattern (excluding flushing cistern and flush pipe)water closet squatt pattern complete including provn of lime concrete bedding complete all as specified and as directed.
70S&F in repair PVC low level flushing cistern 10 litres, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe complete all as specified and directed.
71S&F Vitreous China counter top oval type coloured wash basin suitable size including swan neck pillar taps with bottle trap but including waste pipe fixing on counter with stainless steel brackets complete all as specified and as directed.
72S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect complete all as specified and as directed.
73S&F in repairPVC (SWR) multifloor trap with grating including jointing with solvent cement floor trap 100 mm dia outlet plain with grating including jointing to waste pipe fixed in cement concrete 1:2:4, typeB-1 complete all as specified and directed.
74S&FPVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to wall and floor with neceassary fitting complete all as specified and directed.
75S&FPVC (SWR) 110mm bore pipes single socketed in any length with rubber ring joints fixed to wall and floor with neceassary fittingcomplete all as specified and directed.
76S&F PVC (SWR) 110mm bore bends anyradiuscomplete all as specified and directed.
77S&F PVC (SWR) 75mm bore bends any radiuscomplete all as specified and directed.
78S&F PVC (SWR) 75 mm bore junction single (Single "T") equal or unequal with access doorcomplete all as specified and directed.
79S&F PVC (SWR) 110 mm bore junction single (Single "T") equal or unequal with access doorcomplete all as specified and directed.
80S&F designed looking mirror of any size of selected quality 6mm thick glass, mounted on fixed to wall with CPplugs with chromium plated brass screws and cup washer scomplete all as specified and as directed.
81S&F in repair20 mm dia stainless steel 1.0 mm thick fancy typedroppery rod with decorative design matching brackets as approved and knobs (lattu) or end bracket as required incl fitting with 80 mm long SS screw with 75 mm long wooden gitty of appropriate c/s in each end & intermediate support complete all as specified and as directed.
82S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming Fe-410-W(Gde E-250)quality-A complete all as spd and directed .
83S&F Pre-coated galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified.
84M & L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, Chajja ( up to IInd floor) etc making good, cutting exc 10cm and not exc 40cm girth in Stone concrete block or slab walls complete all as specified and as directed.
85Dismantling of concrete by chiseling from RCC members like column , beam, parapet facia, chajja, ceiling,etc exposingthe reinforcement without disturbing the reinforcement free from rust by sand blasting/using chemical , apply a coat of rustolin to remove rust and acralic polymer on old rusted reinforcement proving at places addl reinforcement welding with existing reinforcement as directed wherever required binding RCC 50 mmx50 mm (10 mm gauge welded mesh ) & tack , securing with clips / blinding wire, welding & provision guniting pressure 2.2 to 2.5 kg /sqm with admixer 1 cement 3.5 of sand of thickness 25 to 40 mm including stripping floating with wooden strippers for proper dimension control neccssary form work & scaffolding up to three storey and including height of head room complete surface of guniting to be finished fair with 10 mm thick plaster in cement mortar 1:4 with water proofing compound @3% by weight of cement and construction fibre as per manufacturer instruction cleaning & removing of waste meterial etc as dirply two coat of Water proofing liquid at interval of 8 hours cure for thesurfaces complete all as specified and as directed.
86S&F 0.71 mm thick Plain Aluminium sheeting Alloy 31000 H4 in stepped flashing (measured as the minimum rectangle from which the pieces can be cut) complete all as specified and directed.
87M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coatof red oxide zinc chrome primer complete all as specified anddirected.
88M&L for preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over and including one coatof pink primer complete all as specified and directed.
89M&L for preparation of old painted wooden or wood based surfaces of any description n.exc 10 cm in width or girth when unconnected with other painting or when painted in a diferenttint and applying one coat of synthetic enamel paint over and including one coat of pink primer complete all as specified and directed.
90M&L for complete removal of existing treatment on wall by scrapping with mechanical sander (having mechanical vaccum mechanism ) with sanding pad of appropriate grit to make surface clean ,free from dust ,loose paint etcby skilled labour and applying two coat OBD on wall with airless electric sprayers over a coat of primer applied using airless electric sprayer over two coat of wall care putty of 1mm thickness complete all as specified and directed. Note:-Application to be done through authorised dealer.
91M&L for applying of two coat OBD on newly plastered surface of wall with airless electric sprayers over a coat of primer applied using airless electric sprayers over two coat of wall care putty of 1 mm thickness prepared and sanded with electrically operated sanding machinecomplete all as spd and directed .Application to be done through authorized applicator complete all as specified and as directed.
92M&L for preparation of newly plastered surface of walls and applying two coats of Dust Resistant and Anti Algal weather proof exterior emulsion paints over a one coat of wall care putty complete all as specified and directed.
93M&L for complete removal of existing treatment onsurfaces of walls including cleaning the surface throughly by using wire brushes and removing use materials from the surface and applying two coats of Dust Resistant and Anti Algal weather proof exterior emulsion paints over a one coat of wall care putty complete all as specified and directed.
94M&L for preparing newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
95M&L complete removal of existing treatment on ceiling,etc including cleaning of any mortar drops ,fungus efflorescent salts etc and prepration of old plastered surface and applying two coat of white wash complete all as specified and as directed.
96M & L for cutting existing steel tubing upto 50mm dia and inserting suitable GI fittings etc for alterations/addition the branch connection complete.
97Supply & layingGIpipemedium grade including fittings 25mm dia including taking downunsv serviceable GI pipe of any size complete all as specified and as directed.
98Supply & layingGIpipemedium grade including fittings 20mm dia including taking downunsv serviceable GI pipe of any size complete all as specified and as directed.
99Supply & layingGIpipemedium grade including fittings15 mm dia including taking downunsv serviceable GI pipe of any size complete all as specified and as directed.
100Supply & fix in replacementgun metal gate valve with Iron wheel head, screwed both ends for pipe 25 mm dia complete all as specified and as directed.
101Supply & fix in replacement gun metal gate valve with Iron wheel head, screwed both ends for pipe 20 mm dia complete all as specified and as directed.
102S&F stop bib tap opper alloy with high pressurewith crutch handle fancy typescrewedboth ends for rion pipe or for union and fixed to 15 mm dia bore GI medium grade pipe complete all as specified and as directed.
103Taking down copper/aluminum point wiring complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fittings, holders etc and removing the items from site to store for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces to match with the existing surfaces of walls, floors etc complete all as specified and directed.
104Taking down main switch/ MCB DBs including MCCBs etc of any size and removing the items from site to store for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces to match with the existing surfaces of wall, floors etc complete all as specified and directed.
105Taking down ceiling/exhaust fan and disconnecting, removing to store for keeping in safe custodyfor BER Board or rehanging etc after some minor repair complete all as specified and directed.
106Taking down electric geyserand disconnecting ,removing to store forkeepingin safe custodyfor refixingetc completeall as specified and dircted and refixing the same as its original postion.
107Taking down submainwiring/service cableincluding earth wire and removing from site to store for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces to match with the existing surfaces of walls, floorscomplete all as specified and directed.
108M & L for point wiring with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor FRLS1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including PVC concealed conduit with all accessories including 1.5 sqmm copper multistrand conductor FRLS1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover incl cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth complete all as specified and as directed following for one light point/fan/Exh fan /bell point controlled by one way switch.
109One light/fan point/ Exhaust fan controlled by one switch.
110One 3 pin socket outlet 5 Amp on same board
111One 3-pin socket outlet 5 Amp on independent board.
112One light point controlled by two way switch
113S&F switch piano flush type single pole one way 5 Amps complete all as specified and as directed.
114S&F Switch Piano flush type single pole one way 15 Amps complete all as specified and as directed.
115S&F Switch Piano flush type single pole two way 15 Amps complete all as specified and as directed.
116S&F Socket outlet 2 in 1, 3 pin 5 Amp flush type complete all as specified and as directed.
117S&F socket outlet 2 in 1, 3 pin 5 Amp and 15 Amps complete all as specified and as directed.
118S&F Lamp holder, PVC/Polycarbonate type with back plate for batten fittings complete all as specified and as directed.
119S&F rechageable Lamp LED 15 Watt 230 Volt complete all as specified and as directed.
120S&F ceiling rose, 3terminals, PVC polycarbonate isolated body complete all as specified and as directed.
121S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as requried complete all as specified and as directed.
122S&F in repairsLED bulk head luminairehexafit 10 watt LEDenvironmental friendly, ultra modern , energysaving , surfacemounted , decorativehexagonalbulk headback lit LED luminariescomprisingof high brrightnessLED complete all as specified & as directed.
123S&F in repairssurface and wall mountedLEDTube lightbattenwith polycarbonatehousing and integtatedeletrinic driverfittings 20 Watt ( T-8 ), 4"including connecting up with 3 core flexible copper conductor cable of suitable size complete all as specified & as directed.
124S&F in repairssurface and wall mountedLEDTube lightbattenwith polycarbonatehousing and integtatedeletrinic driverfittings 10 Watt ( T-8 ), 2"including connecting up with 3 core flexible copper conductor cable of suitable size complete all as specified & as directed.
125S&F in repairs new generationLED building security light fitting 35 Watt 230 Volts AC out door type energy saving andenvrionmental friendlylong lifeLED street light made out ofwith high pressure die cast aluminium housing with high efficiency LED asc lighting source andlens embeded PC cover having bottomopening seperate drivercomponentwith IP 66 protectionand impact resistance of IK08 including electric conection complete all as specified & directed.
126S & F exhaust fan AC single phase, metallic body , heavy duty, 230/240 Volts, of size 300 mm sweep with louversincluding making suitable sizehole in the wall for air flow and grouting of nuts & bolts and washers including making connection with three core copper cable of size not less than 1.5 sqmm from ceiling rose complete all as specified & directed.
127Hanging only geyser aftercleaning& making functional by replacement of thermostat ,NRV ,angle valve, heating element , inner tank( if required), hot and cold pipe 450 mm long braided hose required replacementandconnection etc. painting andremarking the serial MESnos etc complete including electric connection with three core flexible PVC insulated copper conductor multistranded whitein clour 2.5 sqmmcableincluding plug topcomplete all as specified and as directed.
128S&F in repairs round shape 10 watt recessedmounted LED down lighter with white powder coated alu housing with integrated electrinic driverTHD<10% 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light completefor roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as approved by GE.
129Supply and fixing ceiling fans 1200 mmsweep complete with blades, down rod , electronic regulator and accessories, 230 V, 25 watt to 36 watt ,minair delivery 210 CFM with service value 6.00 BEE(Five star ) rated brushless direct currentmotor (BLDC) and markingthe serialMES fan Nos etc inclding electric connectionwith three core flexiblePVCinsulatedcopperconductor multistrandedcable 1.0 sqmmcompleteall as specified and directed.
130S & FGI bracket made out fromGI pipe 32/25mm dia, 1.2 mtr long bend to shape including 02 Nos 25x4 mm MS clamps,nuts, bolts washersfixed on wall & including painting etc complete all as specified and as directed.
131S&F sheet metal enclousers (DBs) when MCBs to be used 8 way double doorwith 200 Amps rated bus bar complete all as specified and as directed.
132S&F sheet metal enclousers (DBs) when MCBs to be used 12 way double doorwith 200 Amps rated bus bar complete all as specified and as directed.
133S&F sheet metal enclousers (DBs) when MCBs to be usedVertical three phase and neutral (VTPN)6 way double doorwith 200 Amps rated bus bar with MCCB incommercomplete all as specified and as directed.
134Supply and fix MCCBs 415V,16 KA, 3 Pole 125 -160 Amps complete all as specified and as directed.
135S&F MCB single phase and neutral 40-63A,240Volt C- curve complete all as specified and directed.
136S&F MCB single pole 40A,240Volt B-curve complete all as specified and directed.
137S&F MCBSP 6A-32A, 240Volt B curve complete all as specified and directed.
138S&F single pole and neutral enclosurewith a two pin earth plug and socketcomplete with one SP MCB 20 Amps complete all as specified and as directed.
139S&F sub main wiring with 2 run FRLS PVC insulated and unsheathed multistrandedcopper condutorof nominal cross section area 2.5 sqmm alongwith one run of FRLS PVC insulated and unsheathedmultistrandedcopper conductor of nominal cross secrtionalarea 2.5 sqmm as earthcontuinity conductordrawnthroughin and including PVC conduit complete all as specifiedandas directed.
140S&F sub main wiring with 2 run FRLS PVC insulated and unsheathed multistrandedcopper condutorof nominal cross section area 4.0 sqmm alongwith one run of FRLS PVC insulated and unsheathedmultistrandedcopper conductor of nominal cross secrtionalarea 4.0 sqmm as earthcontuinity conductordrawnthroughin and including PVC conduit complete all as specifiedandas directed.
141S&F sub main wiring with 2 run FRLS PVC insulated and unsheathed multistrandedcopper condutorof nominal cross section area 6.0 sqmm alongwith one run of FRLS PVC insulated and unsheathedmultistrandedcopper conductor of nominal cross secrtionalarea 6.0 sqmm as earthcontuinity conductordrawnthroughin and including PVC conduit complete all as specifiedandas directed.
142Excacvation in trenches not exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/loose for laying cables complete all as specified.
143Returning, filling in including spreading, levelling, watering and well ramming in layers n exc 25 cm in soft/loose soil complete all as specified.
144Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed.
145Supply & layingsub class B bricks, well burnt , laid wirdthwise along the length of cable laid in trench over sand cushion laid for cable protection, complete as specified and directed.
146Material and labour for river washedand sreened, dry sand for filling in trenchbelow and aroundthe under ground cable for cushioning of cable etc, complete all as specified.
147Boring of holes under road or cutting the road/path/pavement/hard standing or any other situation bymannualmeansfor 25mm bore GI pipe for crossing the cable and making good both the ends all as specified and directed at site. Note :- GI pipeshall be measured and paid separately under respective item.
148Supply & fix tube40 mm borelight grade GIwith all fittingsfor cable protection for road crossing/ culvert/ path/ on wall/ floor/ pole/across the road/path/culverts or laid in floor complete all as specified and as directed.
149Supply, Laying and testing cable XLPE insulated, screened, PVC bedded,GI steel strip or wire armoured, electric power cable ( heavy duty ), 1100Volts with stranded aluminium conductor of size 70 sqmm 3.5 core including taking downservice connection/UG cable removing at site complete all as specified and as directed.
150M&L for earthling complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directrly in ground (earth pit not less than 2.25 mtr deep blow GL with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of vharcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised earth lead wire 4mm connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 40 mm dia GI pipe light grade for protection of GL earth strip and 20 mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type B1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 Mtr, Provision of charcoal and slat complete all as shown in electrical plate No 3 of schedule SSR Part-I. Note : (i) Cost of GI earth strip /GI earth wire and GI protection pipe upto 7.5 mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling, removing, PCC chamber pit ,RCC cover slab with handle for lifting , test point etc.