| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 2 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size,well rammed and consolidated and grouted with fine sand, includingnecessary excavation, levelling & dressing & finishing the top smooth. |
| 3 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stoneaggregate 20 mm nominal size) |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Providing and fixing wire gauge shutters using galvanized M.S. wiregauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :With ISI marked stainless steel butt hinges of required size Second class teak wood |
| 7 | Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. |
| 8 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. |
| 9 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nutsand screws etc. complete : :250x16 mm |
| 10 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 11 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992with necessary screws etc. complete :125mm |
| 12 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 13 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade, with necessary screws etc. complete :125mm |
| 14 | Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade, withnecessary screwsetc. complete.Twin rubber stopper |
| 15 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as requiredIn gratings, frames, guard bar, ladder, railings, brackets, gatesand similar works |
| 16 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 17 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated \"J\" or \"L\"hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheetsshall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniformpigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.2 mm thick flat |
| 18 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 19 | Wall painting with acrylic emulsion paint of approved brand andmanufacture to give an even shade :Two or more coats on new work |
| 20 | Painting with synthetic enamel paint of approved brand and manufactureto give an even shade :Two or more coats on new work |
| 21 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 22 | P/A birla/Jk wall putty of 1 mm thick to make the surface smooth |
| 23 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead :With cement mortar 1:4 (1cement: 4 coarse sand) |
| 24 | Renewing glass panes, with putty and nails wherever necessary includingracking out the old putty:Float glass panes of thickness 4 mm |
| 25 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 26 | Demolishing cement concrete manually/ by mechanical mean including disposal of material within 50 metres lead as per direction of Engineer - in - chargeNominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 27 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stackingwithin 50 metres lead :Of area beyond 3 sq. metres |
| 28 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 29 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bore |
| 30 | Providing and fixing uplasticised PVC connection pipe with brass unions :sand papering etc to prepare smooth as per direction of Engineer-in-charge.45 cm length 15 mm nominal bore |
| 31 | Providing and fixing C.P. brass long body bib cock of approved qualityconforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 32 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a)15mm nominal bore |
| 33 | P/F SS Trap Jali of approved make etc complete |
| 34 | Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion :Powder coated aluminium (minimumthickness of powder coating 50 micron) |
| 35 | Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Shutter :Powder coated aluminium (minimumthickness of powder coating 50 micron) |
| 36 | Providing and fixing 12 mm thick prelaminated particle board flatpressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windowsshutters and partition frames with C.P. brass / stainless steel screwsetc. complete as per architectural drawings and directions of engineerin-charge. |