Tender For Re Appropriation And Additional/Alternator In Building No P 130 At Mil Stn Agartala, Agartala-Tripura

Military Engineer Services-MES has published Tender For Re Appropriation And Additional/Alternator In Building No P 130 At Mil Stn Agartala. Submission Date for this Tender is 02-01-2024. Building Work Tenders in Agartala Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

41178427
Tender For Re Appropriation And Additional/Alternator In Building No P 130 At Mil Stn Agartala
Open Tender
Indian
Tripura
Agartala
02-01-2024

Tender Details

Tender For Re Appropriation And Additional / Alternator In Building No P 130 At Mil Stn Agartala

Key Value

Document Fees
INR 500 /-
EMD
INR 44000.0 /-
Tender Value
INR 22 Lakhs /-

BOQ Items

Name of Work: RE-APPROPRIATION AND ADDN / ALTN IN BUILDING NO. P-130 AT MIL STN AGARTALA.
Sl. No. Item Description
1Demolition of cement concrete (unreinforced) in ground floors and paving n.exc.15cm thick (below or above ground level) and removal of rubbish from the site complete all as specified and as directed.
2Material and labour for 25mm thick PCC 1:2:4 type B-1, (using 20mm graded aggregate) as in sub base of floorand finish the surface fair and even to receive floor tiles complete all as specified and as directed.
3Material & Labour for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, dark shade, area of each tiles not exceeding 0.36 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I).
4Material & Labour for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, dark shade, area of each tiles not exceeding 0.36 sqm, as in skirting of wall etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10 mm thick plaster / backing coat in CM 1:4 complete all as specified and directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I).
5Material & Labour for joint free non skid ceramic coloured tiles7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.11 sqm but not exc 0.18sqm in floors etc.set & jointed in neat cement slurry & pointed in white or coloured cement to match the shade of tiles including screed bed of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I)
6Dismantlingfloor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceabletiles to store and rubbish off the premises complete all as specified and as directed.
7Material & Labour for joint free non skid ceramic coloured tiles7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.11 sqm but not exc 0.18sqm as in skirting/dado, set & jointed in neat cement slurry & pointed with white/coloured to match the shade of tiles over and including rendering of 10mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I).
8Material & Labour for joint free glazed ceramic coloured tiles 350 x 250 x 7 mm thick of premium quality as inskirting/dado, set & jointed in neat cement slurry & pointed with white/coloured to match the shade of tiles over and including rendering of 10mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I).
9Material and labour for complete removal of existing treatment of wall, making good any undulation and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over old prepared surfaces complete all as specified and as directed.
10Material and labour for 3mm thick wall care putty on wall complete all as specified and as directed.
11Material and labour for preparation of old decorative surface of ceiling, washing, rubbing down and stopping of distemper and painted surface and applying two coats of oil bound distemper complete all as specified and as directed.
12Supply and fixing powder coated (minimum 50 micron thick) aluminium sliding type, three track window (two glazed and one gauged shutter), aluminium section weighing not less than 1.67kg/m for frame and 0.55 Kg /mfor shutterincluding necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos.),suitable handle (1 No.) and 5.50mm thick tinted glass and aluminium mosquito proof gauge including taking down old existing steel window and making good disturbed surface of wall complete all as specifiedcomplete all as specified and as directed. (Note: Window opening size to be measured for payment purpose.)
13Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed.
14Materials and labourBrick work with sub class B bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
15Supply and fixing exposed GI powder coated snap grid frame forfalse ceiling of size 600mm x 600mm of wall angle 25x25x0.35mmwith main runner 38 x 24x0.70mm including Supply and fixing of4 mm thick High Pressure Non asbestos Fibre Cement pre painted decorative board (E-board Classic) in a grid of GI system duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing position for light fixtures, air conditioning diffusers and ducts, sprinkler, smoke detectors etc. The main runner to be secured to structural soffit by hangers @ 1200 mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450 mm from the adjacent wall, Flush fitting 1200 mm cross Tee to be interlocked between main runners @ 600 mm c/c so as to form 600mm x 600mm grid complete all as specified and as directed.
16Material and labour for preparation of old decorative surface of wall, washing, rubbing down and stopping of distemper and painted surface and applying two coats of cement base paint complete all as specified and as directed.
17Surface dressing n.exc 15 cm deepin soft/loose soilcomplete all as specified and directed.
18Material and labour for hardcore of broken bricks, gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
19Material and labour for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, paving, footpath etc and finished the surface even and smooth without using extra cement completeall as specified and as directed.
20Material and labour for precast cement concrete chequered tiles of size 200 x 200 x 25 mm thick shall be laid on floor etc set, jointed and pointed in neat cement slurry laid over and including 15mm thick screed bed / bedding layer in CM (1:4) complete all as specified and as directed.
21Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for Key, scrubbingdown with water etc. complete all as specified and as directed.
22Materials and labour for 10 mm thick rendering on fair faces brick work in cement mortar (1:6) andfinished the surfaceseven and smooth without using extra cementcomplete all as specified and as directed.
23Supply and fixing as in repair vitreoues china WHBwhite, flat back, of size 550X400mm including CP brackets, pillar tap 15 mm bore vhromium plated cast copper alloy with capstan heads,CP waste coupling 32 mm bore including 15mm bore PVC connection pipe 450mm long with PTMT nuts at both ends, 32mm dia PVC waste pipe complete all as specified and as directed.
24Supply and fixing as in repair 10 litre capacity low level PVC flushing cistern white, syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete all as specified and as directed.
25Supply and fixing as in repair for looking mirror ofsize 600mm x 450mm bevelled edge of selected quality glass, decorative type mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers with sheet glass assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long completeall as specified and as directed.
26Supply and fixing as in replacement 125mm dia chromium plated shower rose with revolving joints fixed to 15mm bore GI Pipe complete all as specified and as directed.
27Supply and fixing as in repair vitreous china squatting pan ‘Orissa pattern’,white, of size 580 mm x 440mm (white) with ‘P’ or ‘S’ trap, front or back inlet with integral foot rests, any pattern complete including provision of PCC bedding andconnection to trap, flushing pipe, antisyphonage pipe, etc. including making good the disturbed floor complete all as specified and as directed.
28Supply and fixing as in repair vitreous china bowl pattern urinal, flat back of size 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including connections to flushing pipe and outgoing pipes complete all as specified and as directed.
29Supply and fixing in repair stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
30Supply and fixing asin replacement 15mmbore dia bib tapscastcopper alloy chromium plated, fancy type , long neckwith crutch or butterfly handle, screwed down, screwed for iron pipecomplete all as specified and as directed.
31Taking up or down steel tubing 15mm bore and connections complete all as specified and as directed.
32Supply and fixing 15mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and as direcetd.
33Supply and fixing in repair 15mm bore stop valve,cast copper alloy, chromium plated, screwed down high pressure with crutch or butter fly handle screwed both ends fixedto GI pipe complete all as specified and as directed.
34Taking up or down steel tubing 20mm bore and connections complete all as specified and as directed.
35Supply and fixing 20mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and as direcetd.
36Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors etc. complete all as specified and directed.
37Material and labour for point wiring (surface type) for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing caping of suitable size with all accessoriesand PVC rectangular boxes for mounting switch, socket and fan regulator etc complete all as specified and as directed. Note: (i) Wiring shall be done in proper colour coding using red , yellow, blue for phase, black for neutral and green for earth. (ii) The cost of making good the disturbed surfaces is deemed to be included in the quoted rate.
38Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed.
39Supply and fixing ceiling rose, PVC/polycarbonate, isolated body surface bakelite, 62.5mm x 50mm,ISI marked three terminals complete all as specified & directed.
40Supply and fixing Square recessed mounted Flat Panel LED Light of 36 Watt suitable for fixing in 2" X 2" Grid False Ceiling, 6500 K, with high transmitive diffuser for soft-light and glare free symmetrical illumination with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down of old unserviceable tube light complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
41Material & Labour for sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 6.00 sqmm (Nominal area) drawn through in and including PVCCasing/ Caping with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 6.00 sqmm as earth lead and connected to earth dolly and including taking down old unserviceable sub main wiring of any description, making good to disturbed surfaces complete all as specified as directed. Note : (i) 3 Runs of 6.00 Sqmm cable and one run of PVC Casing/ Caping shall be measured as one unit length.
42Material & Labour for sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.00 sqmm (Nominal area) drawn through in and including PVCCasing/ Caping with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.00 sqmm as earth lead and connected to earth dolly and including taking down old unserviceable sub main wiring of any description, making good to disturbed surfaces complete all as specified as directed. Note : (i) 3 Runs of 4.00 Sqmm cable and one run of PVC Casing/ Caping shall be measured as one unit length.
43Supply & Fixing MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall including taking down of existing unserviceable DB with MCBs including making good disturbed surfaces complete all as specified and as directed.
44Supply & Fixing MCB SPN, 32 Amp having breaking capacity 10 KA, 240 Volt "C" Curve complete all as specified and directed.
45Supply and fixing MCB, single pole, 25 Amp, having breaking capacity 10 KA,240 volts, "C" Curve complete all as specified & directed.
46Supply and fixing MCB, SPN, 40 Amp, having breaking capacity 10 KA, 240 volts, "C" Curve complete all as specified & directed. Note for serial Item No. 43 to 46: MCB and MCB DB shall be of same make as approved by AGE (I).
47Supply and fixing in repairs SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amp, 240 Volts complete all as specified and as directed.
48Supplying, installing, testing and commissioning of minimum 3 Star rated Hi-Wall Split Units Indoor / Outdoor with Cordless Remote Control Unit and with in-built advanced Air Ioniser and Plasma Filters for better indoor air quality with latest Inverter technology, having Eco friendly Refrigerant Gas, Copper Condenser Coil, EER 3.2 of Capacity 1.5 TR, Summer Cool, Dual Rotor Inverter Compressor, Automatic 4D Swing Copper Condenser, Motor, necessary copper pipe connections including cutting, bending, brazing, insulation on pipe etc, PVC Drain Pipe, electric connection between indoor and outdoor unit with suitable size PVC insulated, multi-stranded copper cable complete all as specified and as directed. Note: (a) The quoted rate is deemed to include cost of cutting chases / drilling holes through wall for connection to outdoor unit as required. (b)The rate quoted by the contractor is deemed to include cost of Powder Coated Mild Steel Fixing Brackets for Outdoor and Indoor Units at any height and Copper tube of suitable size and length and Drain Pipe made of High Density Polyethylene Pipes [HDPE] of pressure rating 6 KGf / Sq.cm of 25mm dia as per manufacturer"s instructions upto 5m length.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail