Tender For Special Repairs To Bldg No.P-624 Of Army Ad Centre Under Ge I Gos; 1 Demolition Of Brick Work Or Stone / Boulder Masonry Built In Cement Mortar Including All Quoins, Arches, Pillars Etc Complete All As Specified And Directed. 2 M & L For Brick Work With Sub Class B Brick ( Old Size ) Straight Or Curved On Plan To Any Radius In Half Brick Thick Walls Built In Cm 1:4 To Any Radius Complete All As Specified And Directed. 3 M & L For Old Size Brick Work With Fly Ash Bricks Straight Or Curved On Plan Exc 6M Mean Radius In Cm 1:6Completed All As Specified And Directed. 4 Taking Down Cement Plaster Any Description On Brick Or Stone Walls Or Rcc Roofs / Ceiling Etc Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Complete All As Specified And Directed. 5 M&L For Rendering 15 Mm Thick On Fair Face Of Brick Works In Cm 1:6 Finishedeven And Smooth With Out Using Extra Cement Complete All As Specified And Directed. 6 M&L For Rendering 15 Mm Thick In Cm ( 1:4 ) On Fair Faces Of Brick Or Concrete Surface Of Wall And Finished Even And Smoothwith Out Using Extra Cementand Mixed With Water Proofing Compound @ 3% By Weight Of Cement Complete All As Specified And Directed. ( Note: Supply Only Of Wpc Shall Be Measured And Paid For Seperately ) 7 M&L Rendering 5 Mm Thick In Cement Mortar 1:3 On Concrete Surfaces Of Ceiling And Finishing The Surfaces Even And Smooth Complete. 8 M&L For Preparation Of New Plastered Surfaces Of Walls Or Concrete And Applying Two Coats Of Oil Bound Distemper Over A Coat Of Primer Complete All As Specified And Directed. 9 M&L For Preparation Of Old Decorated Surfaces Of Walls And Apply Two Coats Of White Wash Complete All As Specified And Directed 10 M & L For Applying Two Coats Ofoil Bound Distemper On Wall Or Concrete Over A Coat Of Primer On Prepared Surfaces Including, Rubbing With Sand Paper After Complete Removalof Existing Treatment Complete. 11 M&L Applying Two Coats Of Acrylic Exterior Weather Roof Emulsion Paint Over A Coat Of Exterior Grade Wall Putty And Exterior Primer On Newly Plastered Wall Surfaces / Old Decorated Wall Surfaces In Case Of Old Decorated Wall Surfaces Including Complete Removal Of Existing Wall Finish Of Any Type With Wire Brush, Brooming, Dusting & Finally Washing With Water To Clean The Surface Absolutely Free From Any Kind Of Foreign Materials & Making Good Minor Cracks Etc Complete All As Specified And Directed. 12 M&L For Preparation Of Old Surfaces Of Ceiling And Applying Two Coats Of White Wash Complete All As Specified And Directed. 13 Taking Down Chowkhat Or Frames N Exc 1.50 Sqm Each With Shutters ( Without Taking Off Shutters From The Frame ) Complete All As Specified And Directed 14 Taking Down Chowkhat Or Frames Exc 1.50 Sqm And N Exc 4 Sqm Each With Shutters ( Without Taking Off Shutters From The Frame ) Complete All As Specified And Directed 15 Taking Down And Refixing Ofshutter Of Any Description Not Exc 1 Sqm Each Leaf In Same Opening After Easing And Adjusting Building Hard Ware Etc Complete All As Specified And Directed 16 Taking Down And Refixing Of Shutter Of Any Description Exc. 1 Sqmbut Not Exc 2 Sqm Each Leaf In Same Opening After Easing And Adjusting Building Hard Ware Etc Complete All As Specified And Directed 17 S&F Second Class Hard Wood ( Sal ) Plain, Solid, Straight Chowkats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue Pinned At Joints Complete All As Specified And Directed. 18 M & L For Preparing Surfaces Of Wood And Wood Based Materials, Any Description And Girth, Not Otherwise Described, Andtreating Ends Of Posts, Backs Of Chowkats, Etc., Area Tarred Exc 0.1 Sq. M But N Exc 0.5 Sq. M Each Complete All As Specified And Directed. 19 M & L For Preparing Surfaces Of Wood And Wood Based Materials, Any Description And Girth, Not Otherwise Described, Andtreating Small Articles Such As Stop, Covers, Gully Gratings, Holdfasts, Ends Of Posts, Backs Of Chowkats, Etc., Area N Exc 0.1 Sq. M Each, Complete All As Specified And Directed. 20 S&F Second Class Hard Wood 30 Mm Thick Factory Made Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauze Etc With Out Sash Bars, Edges Of Framing Plain, Chamfered Or Rounded, Fitted With Cut And Mitred Beads For Securing Glass, Gauze Etc, Sizes Of Members Of Shutters As Specified In Ssr Part I Section 8 Clause 8.24 ( A ) Complete All As Specified And Directed. 21 S & F 35 Mm Thick Second Class Hard Wood Rail And Style Plain, Framed, Factory Made Panelled Shutters ( Two Panels ) With Lock Rail And Panel Of 9 Mm Thick Bwp Commercial Ply Or 12 Mm Thick Veneered Particle Board With Commercial Veneering On Both Faces. The Size Of Rail And Stiles Are As Per Is – 1003 ( Part – I ) , Kiln Seasoned & Chemically Pressure Treated Complete All As Specified And Directed. 22 S&F Mild Steel Flat Iron As In Bands Straps, Supports Or Stays For Rainwater, Ventilating Pipes Including Bolt If Required, Hooks ( Stay ) Heavy For Large Gates, Hook And Pintle Hinges, Large Hasps And Staples, Brackets For Whb, Hold Fasts, Wall Ties, Hooks For Hanging Fans , Cleats For Securing Purlins To Wood Trusses Or Rafters And Similar Small Articles Conforming To Fe -290 Gde E-165 Complete All As Specified And Directed. 23 M&L For Cutting Holes In Brick Walls Exc Half Brick But Not Exc One Brick Built In Cement Mortor Or Cement Lime Mortor And Stone Walls Built In Lime Mortor For Inserting Hold Fasts And Makinggood Dismantled Portion In Cement Mortar 1:3 Or Cement Concrete 1:2:4 Type B-1 As Requiredcomplete All As Specified And Directed. 24 S&F 2Nd Class Hardwood Beads, Straight ( Any Size ) For Glazed Or Gauzed Joinery, Renewed, Including Mitres Etc., And Removing Old Beads To Store 25 Hacking Out Old Broken Glass ( Any Thickness, Size Quality Or Description ) Form Wooden Frames Or Steel, Alu, Concrete Or Brick Surrounds Glazed With Oil Putty Or Fixed With Beads Complete All As Specified And Directed. 26 S&F 3 Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square Not Exceeding 0.5 Sqm In Each Pane, Complete All As Specified And Directed. 27 S&F In Repair 300 Mm Mild Steel Ordinary Rat Tail Rod Pattern Springs Including Roller And Roller Plate Complete All As Specified And Directed. 28 S & F For Solid Pvc Door Frame Of Size 50X47mm Made Out Of 5 Mm Plain Colour Pvc Sheet Reinforced With Ms Square Tube, Supplied And Fixing In Opening As Specified And Shown On Drawing Made On Section 8 Of Ssr 2010 Part-Ii Complete All As Specified Anddirected 29 S & F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick Style Consisting Of Frame Made Out Of Ms Tube For Top And Bottom Rails.Ms Frame Shall Be Covered With Heat Moulded Plain Colour Pvc “C” Channel Having A Pvc Sheet Strip Of 20 Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheet For Top Rail, Lock Rail And Bottom Rail On Either Side And As Gap Insert For Top Rail And Bottom Rail, Panelling Of Plain Colour Pvc Sheet To Be Fitted In The Ms Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading And Jointed Together With Solvent Cement, S & F In The Frame As Per Specifications And Shown On Drawing In Section 8 Of Ssr-2010 Part-Ii Complete All As Specified Anddirected 30 S&F In Repair 100 Mm Long Butt Hinges Extruded Aluminium Alloy With Galvanised Mild Steel Hinge Pin Anodised Type B-21 Complete All As Specified And Directed. 31 S&F In Repair 150 Mm Size Extruded Aluminium Alloy Handles Fabricated Type Anodised Ofcomplete All As Specified And Directed. 32 S&F In Repair 150 Mm Long Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section Complete All As Specified And Directed. 33 S&F In Repair 250 Mm Long Aluminium Alloy, Anodised Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast Aluminium Alloycomplete All As Specified And Directed. 34 Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For Complete All As Specified And Directed. 35 M&L For Preparation Of Old Painted Surfaces Of Wood And Wood Based Surfaces Of Any Description, Over 10 Cm In Width Or Girth And Apply One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed. 36 M&L For Prepararion Of Old Painted Surfaces Of Steel Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint On Surfaces Complete All As Specified And Directed. 37 S&Fpowder Coatedthree Track Aluminium Sliding Window With Frame Not Less Than 1.00 Mm Thick Excluding Aluminium Grill And Including4 Mm Thick Tinted Glass, Aluminium Snap Beading & Necessary Rubber Packing, Locking & Opening Arrangement, All Fitting And Fixtures Complete All As Specified And Directed By Engr-In-Chrg 38 S&F Powder Coated Aluminium Ventilator With Frame Not Less Than 1.8 Mm Thick & Including 4 Mm Thick Tinted Glass Including Beading & Necessary Rubber Packing, Locking & Opening Arrangement If Required, All Fitting And Fixture Complete All As Specified And Directed. 39 S&F 7Mm Thick Aluminium Grills Of God Quality Surrounded By Aluminium C Channel With Mesh Size 75 X 75Mm Complete All As Specified And Directed. 40 S&F In Stainless Steelwire Cloth 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4 Mm Fixed With Stainless Steel Wire Staples Or With Necessary Beads Complete All As Specified And Directed. 41 Demolition Of Cement Concrete ( Un-Reinforced ) Roofs, Floors ( Other Than Groundfloors ) , Beams, Staircases, Landing, Chajjas And Similar Suspended Work Compelte All As Specified And Directed. 42 M&L For 40 Mm Thick Cement Concrete 1:2:4 Type B-0 ( 20 Mm Graded Stone Aggregate ) As In Rcc Roof Surface With Mixing Of Water Proofing Compound @3% By The Weight Cementto Horizontal Or Vertical Surfaces Finished Cement Concrete Surface Even And Smooth Using Extra Cement Including Necessary Form Work ( Water Proofing Compound Will Be Measured Separately ) 43 Taking Down Existing Water Proofing Treatment / Membrane Of Any Type And Cleaning The Surface Of Roof, Palstered Surfaces Etc By Roughening, Picking, Sweeping Clean And Washing Down With Water To Remove All Loose Dirt Etc And Preparing The Surface To Receive Plaster And Brushing Neat Cement Slurry @ 3.00 Kg Of Cement Per Sqm Complete All As Directed By Engr-In-Chrg 44 M&L For Rendering 15 Mm Thick Surface As In Roof With Integral Water Proofing Compound @ 3% By The Weight Of Cement In Cm 1:4 Complete All As Specified & Directed. ( Integral Wpc Will Be Measured And Paid Separately ) . 45 M&L For Water Proofing Treatment To Roof Surface Complete All As Specified & Directed By Engr-In-Charge Laid With Following Course Of Descrition Below :- :- ( A ) Apply Evenly Bituminous Based Primer Confirming To Is: 3384-1965 @ 0.30 Kg / Sqm. ( B ) App Modified Bituminous Membrane 3Mm Thick With Non Woven Polyester Core Of Weight Not Less Than 3.2 To 3.5 Kg / Sqm Laid And Bonded To The Sub Strata By Heat Process, Over Laps Of 100Mm Shall Be Sealed / Fused By Flame Torch Application As Per Manufacturer Instructions. ( C ) Applying Bituminous Based Aluminiumpaint @ 0.20 Kgs / Sqm In Two Coats Over App Membrane 46 Supply Only Integral Water Proofing Compound All As Specified. 47 Dismanting Of Existing Sunken Floor Treatment Incl Plaster And Removal Of All Debris And M&L For Water Proofing Treatment On Existing Sunken Floor / Wall With The Following Specification And Sequence Complete All As Specified And Directed By Engr-In-Chrg ( A ) Cleaning The Internal Surface Areas Thoroughly So That They Are Free Of All Contaminants Like Dirt And Laitance & To Remove All The Loose Materials By Various Mechanical / Manual Means. ( B ) Removal Of All Surface Imperfections, Protrusions , Loose Concrete & Filling Of Cracks Using Dr Fixit Pidicrete Urp Modified Mortar In The Ratio Cement: Sand ( 1:4 ) And 5% By Weight Of Cement. ( C ) Providing And Making Fillets At The Junction Of The Walls And The Slabs Using Cement Mortar Of 1:4 Mix Admixed With 5 % Of Dr. Fixit Urp By Weight Of Cement. ( D ) Applying Two Coats Of Elastomeric Compound Viz Beck Bond Wpc-30 / Master Coat Irc Over One Coat On Neat Primer I.E. Super Latex Of Dr Fixit / Master Bond Of Conchem. ( E ) Laying Protection Plaster 15Mm, In Cm 1:4 Admixed With Stp / Drfixit Diproof Lw@200 Ml Per Bag Of Cement. 48 Demolition Of Cement Concrete Unreinforced In Ground Floor And Paving N Exc 15Cm Thick ( Below Or Above Ground Level ) Complete All As Specified And Directed. 49 M&L For Pcc 1:5:10 Type E-2 Using 40Mm Graded Stone Aggregate As Infilling Of Sunken Floor Etc And Mass Concrete Complete All As Specified And Directed. 50 M&L For Pcc 1:2:4 Type B-0 Using 12.5 Mm Graded Stone Aggregate As In Sub Base Flooring 25 Mm Thick Surface Finished Even Andrough To Receive The Topping Layer Complete All As Specified And Directed. 51 M&L For Pcc 1:2:4 Type B-0 Using 12.5 Mm Graded Stone Aggregate As In Sub Base Flooring 50 Mm Thick Surface Finished Even Andrough To Receive The Topping Layer Complete All As Specified And Directed. 52 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding Etc ( But Not Backing ) And Removing Rubbish Off The Premises Complete All As Specified And Directed. 53 M&L For Non Skid Ceramic Coloured Tiles Of Design As Approved By Ge 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm In Floor Etc Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match With The Shade Of Tiles Including 20 Mm Thick Screed Bed In Cement Mortor 1:6 Complete All As Specified And Directed. 54 M&Lfor Glazed Ceramic Coloured Tiles 300 X 450 X 7 Mm Thick On Vertical Surface Such As Dado / Skirting / Risers To Steps Etc Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Surface Of Tiles Over And Including Rendering 10 Mm Thick In Cement Mortor 1:4 Complete All As Specified And Directed. Note- ( I ) The Size Of Tiles ( Except Thickness ) May Be Varied During Execution Without Any Price Adjustment. 55 Taking Up & Down Gi Steel Tubing & Connections Including Cleaning For Refixing Or Removal To Store For 15Mm Bore Of Pipe Complete All As Specified And Directed. 56 Taking Up & Down Gi Steel Tubing & Connections Including Cleaning For Refixing Or Removal To Store 20Mm Bore Of Pipe Complete All As Specified And Directed. 57 Taking Up & Down Gi Steel Tubing & Connections Including Cleaning For Refixing Or Removal To Store 25Mm Bore Of Pipe Complete All As Specified And Directed. 58 Refixing Old Steel Tubing And Connections In New Or Old Position ( Wall, Floor, Ceiling Etc ) Of 15 Mm Bore Of Pipe Complete All As Specified And Directed. 59 Refixing Old Steel Tubing And Connections In New Or Old Position ( Wall, Floor, Ceiling Etc ) Of 20 Mm Bore Of Pipe Complete All As Specified And Directed. 60 Refixing Old Steel Tubing And Connections In New Or Old Position ( Wall, Floor, Ceiling Etc ) Of 25 Mm Bore Of Pipe Complete All As Specified And Directed. 61 Supplying And Laying Of 15Mm Bore Dia, Cpvc Pipes Sdr 11 & Plain Cpvc Sdr 11 Fittings, Fixed On Walls / Ceiling Or Laid In Floors, Etc, Complete All As Specified And Directed. 62 Supplying And Laying Of 20Mm Bore Dia, Cpvc Pipes Sdr 11 & Plain Cpvc Sdr 11 Fittings, Fixed On Walls / Ceiling Or Laid In Floors, Etc, Complete All As Specified And Directed. 63 Supplying And Laying Of25mm Bore Dia, Cpvc Pipes Sdr 11 & Plain Cpvc Sdr 11 Fittings, Fixed On Walls / Ceiling Or Laid In Floors, Etc, Complete All As Specified And Directed. 64 S&F Cpvc Brass Elbow 15Mm Bore Dia Complete All As Specified And Directed 65 S&F Cpvc Brass Elbow 20Mm Bore Dia Complete All As Specified And Directed 66 S&F Cpvc Brass Elbow 25Mm Bore Dia Complete All As Specified And Directed 67 S&F Cpvc Brass Tee 15Mm Bore Dia Complete All As Specified And Directed. 68 S&F Cpvc Brass Tee 20Mm Bore Dia Complete All As Specified And Directed. 69 S&F Cpvc Brass Tee 25Mm Bore Dia Complete All As Specified And Directed. 70 S&F Cpvc Brass Union 15Mm Outer Dia Complete All As Specified And Directed. 71 S&F Cpvc Brass Union 20Mm Outer Dia Complete All As Specified And Directed. 72 S&F Cpvc Brass Union 25Mm Outer Dia Complete All As Specified And Directed. 73 S&F Cpvc Brass Elbow ( 20 / 15 ) 20 Mm Bore Dia Complete All As Specified And Directed. 74 Cutting Chases In Brick Walls, Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Not Exc 10 Cm Girth Complete. 75 S&F In Repair Bib Tap Cast Copper Alloy Chromium Plated With Crutch Or Butterfly Handle Fixed To 15 Mm Dia Gi Tube / Cpvc Pipe All As Specified And Directed. 76 S&F In Repair 15 Mmfancy Type Pillar Taps Chromium Plated Cast Copper Alloy With Capstan Heads Screwed Down High Pressure With Or Without Lettered ‘Hot’ Or ‘Cold’ With Long Screwed Shanks And Fly Nuts . 77 S&F In Repair 15 Mm Fancy Type Stop Valve / Angle Valve Cast Copper Alloy Chromium Plated Screwed High Pressure With Crutch Or Butter Fly Handle Screwed Both Ends For Iron Or Union And Fixed To 15 Mm Gi Tube Complete All As Specified And Directed By Engineer-In-Charge. 78 S&F In Repair 25Mm Dia Ball Brass Valves, High Pressure, With Polythene Float And Fly Nut Complete, Screwed For Iron Pipes Or Brass Ferrule And Fixed As In Pvc Service Tanks All As Directed. 79 S & F In Repairs 25Mm Bore Gun Metal Gate Valves With Iron Wheel Head Screwed Both Ends For Iron Pipe And Fixed. 80 S&F In Repairs Pvc Connection 15Mm Size With Ptmt Nuts, Of 450Mm Length Complete All As Specified And Directed. 81 S & F In Repairs, Vitreous China Wash Basin, White, Flat Back, Size 550X400mm With Brackets, Inc.Cutting For Fixing & Pinning In Ends Of Brackets Including Pvc Waste Pipe Complete All As Directed By Engr-In-Chrg 82 S&F In Repairs Viterious China Squatting Pan Orissa Pattern Size 580X440mm White Integal Foot Rest Including Concrete Bedding & Including P Or S Trap 100Mm Complete All As Directed By Engr-In-Chrg 83 S & F In Repairs, Vitreous China Wash Down Water Closet Pan ( Pedestal Pattern ) , White, Incl P Or S Trap And Plastic Water Closet Seat Cover, Black, Closed Pattern With Flat Bottom And Cover & Ms Chromium Plated Or Aluminised Hinging Device, Complete All As Directed By Engr-In-Chrg 84 S & F In Repairs Vitreous China Urinals, Bowl Type Flat Back Size Of 465 X 355 X 265 Mm White ( Minimum ) With Grating And Union For Discharge Pipe Complete Including Providing And Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar 1:2, Securing Urinal To Plugs With And Including 60 Mm Long Brass Screws, Pointing Around Urinal Back In Cement Including Pvc Waste Pipe Etc Complete All As Sapecified And Directed. 85 S&F In Repair Pvc Low Level Flushing Cistern ( White ) 10 Ltrs Capacity With Inlet, Ball Valve, Float And Handleinternal Fitting, Push Button Operated Type With And Including Brackets Etc Complete. 86 S / F In Repair Cp Brass Health Faucet With Flex Pipe And Hand Shover, The Length Of Hose 1.50 Mtr Fitted To The Tap.Complete All As Specified 87 S&F In Repair Pvc Jet Connector Suitable For Ewc All As Specified And Directed By Engineer-In-Charge. 88 S&F Grating Doom 125 Mm Dia With Waste Hole Of Ptmt Minimum Weight 40 Gms Complete All As Specified And Directed. 89 S&F In Repair Cp Brass Towel Rail `D’ Type 60Cm Long Fixed To Wall All As Spd And Directed By Engr-In-Charge 90 M&L 32Mm Dia Bore Waste Fittings, Brass, Chromium Plated For Glazed Ware Sinks, Basins, Etc.With Long Screwed Shanks And Fly-Nuts, Flange End Bedded In Red Lead Cement And Other End Fixed As In Repairs 91 S&F Bevelled Edge Mirror Of Size 600X450mm Of Selected Quality Glass 4Mm Thick Mounted On 6Mm Thick Ac Building Board Or Commercial Ply Wood And Fixed With Wooden Plugs With Chromium Plated Screws Including Taking Down Existing Mirror . 92 S&F In Repair 75 Mm Pvc ( Swr ) Floor Trap With Grating Including Jointing With Solvent Cement. Complete All As Specified And Directed 93 Demolition And Breaking Up Drain Pipe ( Salt Glazed Ware, Ac Or Reinforced Concrete, Pvc ) Set In Cement Mortor For Any Size & Type Complete All As Specified And Directed. 94 M&L For Pvc ( Swr ) Pipessingle Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Of 75 Mm Bore Of Pipe Etc Complete All As Specified And Directed. 95 M&L For Pvc ( Swr ) Pipessingle Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Of 110 Mm Bore Of Pipe Etc Complete All As Specified And Directed. 96 S&F Pvc ( Swr ) Bends Any Radius Of 75 Mm Borewith Outaccess Door Complete All As Specified And Directed. 97 S&F Pvc ( Swr ) Bends Any Radius Of 110 Mm Borewith Outaccess Door Complete All As Specified And Directed. 98 S&F Pvc ( Swr ) Bends Any Radius Of 75 Mm Borewithaccess Door Complete All As Specified And Directed. 99 S&F Pvc ( Swr ) Bends Any Radius Of 110 Mm Borewithaccess Door Complete All As Specified And Directed. 100 S&F Pvc ( Swr ) Vent Cowl 75 Mm Bore Complete All As Specified And Directed. 101 S&F Pvc ( Swr ) Vent Cowl 100 Mm Bore Complete All As Specified And Directed. 102 Dismantling Pvc Water Tanks Exc 500 Ltr But Not Exc 1000 Ltr Capacity And Removing To Store Complete All As Specified And Directed. 103 S&F 1000 Ltr Capacity Rotational Moulded Polyethylene Water Storage Tanks Of White Colour ( Cylin-Drical Vertical With Closed Top ) Hoisted And Fixed In Position All As Specified Complete. 104 S&F For 25Mm Dia Stainless Steel Curtain Rod With Brackets Complete All As Specified And Directed 105 M&L For Rcc Nominal Mix Type B0 1:2:4 ( 20Mm Graded, Aggregate ) As In Chajjas 106 M&L For Formwork To Soffits And Sides Of Chajjas 107 S&F Mild Steel Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips 108 Taking Down Carefully Copper / Aluminium Point Wiring ( Light, Fan, Bell, Socket Or Power ) Complete, Including Fixtures And Fittings Such As Switches, Ceiling Roses, Holders, Regulators, Sockets, Tube Light Fittings I.E Removingmaterials To Store Forkeeping In Safe Custody Or For Taking Credit ( Credit For Above Items Should Be Made For Conditions Separately ) And Including Making Good The Disturbed Surfaces To Match With Existing Surface And Colour Shade With Proper Puttyfor Smooth Finishing Without Andulations Complete All As Specified And Directed. ( Note:-All Credit Materials Should Be Deposited In Mes Yard As Available On Work Site The Same Materials Should Be Issued To Contractorthrough Gate Passas Per Schedule Of Credit Materials Againstcontract Agreement ) . 109 Materialand Labour For Point Wiring Complete With 1.5 Sqmm, Pvc Insulated, Frlsh Type, Isi Marked, Conforming To Is-694 / 1990 ( As Amended ) Unsheathed, Multistranded, Single Core, Copperconductor Cable 1100 Volts Grade Using Approved Colour Coding Drawn Through And Including Pvcconcealed Conduit 20 / 25 Mm Dia Medium Grade ( Mms ) And Incliding All Accessories Such As Bend, Tee, Elbows, Reducers, Bell Mouth Tube Ends, Short Pieces & Junction Boxes With Pvc Covers Etc Inwalls / Roofs / Floors / Ceiling Etc Andincluding Cutting, Chasing Work At Any Heightwith Flush Mounting Gi Sunken Boxes Having Top, Bottom, Side / Back Side Knockout For Conduitentry From Any Direction Made Out Of 1.60Mm Thick, 60Mm Deep For Housing Modular Switches, Sockets, Fan Regulators, Indicators, Blank Plate Etc And Incl Providingmodular White Cover Plate With Inner Frame Suitable As Per Switch Modules Andincluding Pvc Insulated Multistranded Copperconductor 1.5 Sqmm Frlsh Type Unsheathed ( Green Colour ) , Single Core Cable As Earth Wire Connecting To Common Earth Dolly For Further Connection To Ceiling Rose And Earth Terminal And Including Making Good The Disturbed Surfaces To Match With Existing Surface And Colour Shade With Proper Putty For Smooth Finishing With Existing Wall Complete All As Specified And Directedfor One Light Point Controlled By One 10Amps Switch, One Way. ( Note:- Allnecessary Accessories Such Asmodular Box, Top Cover Plate, Inner Frame, Blank Plate, Gi Sunken Boxes, Screws, Washers And All Modular Electrical Fixtures Are Used Same Make / Brand Only ) 110 All As Per Item No. 109 But Onefan Point Controlled By One Switch 10 Amps, And Oneregulator. 111 All As Per Item No. 109 Oneexhaust Fan Point Controlled By One Switch 10 Amps, One Way 112 All As Per Item No. 109 One 5 Pin 6 Amps Socket Point Controlled By One 10 Amps Switch On Independent Board . 113 All As Per Item No. 109 One 5 Pin 10 Amps Socket Point Controlled By One 10 Amps Switch On Same Board . 114 All As Per Item No. 109 One Light Point Controlled By Two 2 Way Switches. 115 All As Per Item No.109Above, But Point Wiring With 2.5 Sqmm And Earth Conductor Of Size 2.5 Sqmm Complete All As Specified And Directed For One 6 Pin 16 / 20Amps Socket Outlet Point Controlled By One 16 / 20 Amps Switchon Independent Board. 116 All As Per Item No.115One 6 Pin 16 / 20 Amps Socket Outlet Point Controlled By One 16 / 20 Amps Switch On Same Board. 117 All As Per Item No.112 Above , But Point Wiring With 4.0 Sqmm And Earth Conductor Of Size 4 Sqmm Complete All As Specified And Directed. 118 Supply & Fixing Modular Type Switch 10 Amps, Single Pole, 1Way, 1 Module, 240V, Ac, With Small Indicatorisi Markedcomplete All As Specified And Directed. 119 Supply & Fixing Modular Type Switch 10 Amps , 2Way, Single Pole, 1 Module, 240V, Ac, With Small Indicatorisi Markedcomplete All As Specified And Directed. 120 Supply & Fixing Modular Type Switch 16 / 20 Amps, Single Pole, 1Way, 1 Module, 240V, With Small Indicator, Ac, Isi Marked Complete All As Specified And Directed. 121 Supply & Fixing Modular Type Socket Shuttered Type 10 Amps, 2 / 3 Pin Combined 2 Module, 240V, Acisi Marked Complete All As Specified And Directed. 122 Supply & Fixing Modular Type Socket 16 / 20 Amps, 6 Pin Combined Shuttered Socket 2 Module, 240V, Acisi Markedcomplete All As Specified And Directed 123 Supply & Fixing Red Color Lighting Indication Lamp Switch, Single Pole, 240Volts, Ac, 50 Hz Suitable For 1 Moduleisi Marked Complete All As Specified And Directed. 124 Supply & Fixing Modular Type Step Fan Speed Regulator 120W, 2 Module, 230Volts, Ac, 360 Degree Rotation 1 To 8 Steps, Isi Markedcomplete All As Specified And Directed. 125 Supply & Fix Angle Lamp Holder Latest Model, Insulated Pvc Out Side Body And Brass Inside Holder With Back Plate For Batten Fittings / Bulbscomplete All Asspecified And Directed. 126 Supply & Fix Ceiling Rose, 3 Terminal , Pvc / Polycarbonate Body Isi Marked, Complete All As Specified And Directed. Makw :-Havells ( Crabtree ) Or Equivalent In Legrand / Schneider ( Zencelo ) / Aabas Existing Type And As Approved 127 Supply & Fix20 Watt Led Light Fitting Pride Essential Bright Linea White Lighting, High Quality Materials Andslim Intergrated Design, Extruded Aluminium Housing Enhances Safety, Pc Diffuser, Reliable And Robust Housing Structure , Maximize The Endurance Over The Life Time, Easy To Install, Efficency 100 Lm / Wand Including Providing Coloured End Caps, Pre-Wired, And Pvc / Wooden Round / Square Block -02 Nosand Connected With Led Fitting To Ceiling Rose Terminaland Incl Removing Old Unserviceable Fitting Complete All As Specified And Directed. Make :- Havells Ordering Code.Lhexawp7in1w020 Or Equivalent Make In Crompton / Philips 128 Supply And Fixing Led 20 Watt, 6500K, Pride Plusinverter Batten, Decorative Type Light Fitting White Lighting, With Square Profile And Polycarbonate Channel, Lithium Lon Battery With Charging Time 8 Hours To 10Hours And Back Up Time Upto 4 Hours High Quality Materials And Design, Extruded Aluminium Housing Enhances Safety, High Quality Pc Diffuser, Easy To Install, Efficency 125 Lm / Wand Including Providingpre-Wired, And Pvc / Wooden Round Or Square Blocks -02 Nosand Connected With Led Fitting To Ceiling Roseand Removing Old Unserviceable Fitting Complete All As Specified And Directed. Make :-Havells Cat No. Lhexacp7fn1w020or Equivalent Make In Crompton / Philips 129 Supply And Fixing 20 Watts Ledaustra Mirror Smart Light Fitting One Feet Long, Contemporary Design Of Mirror Light Complete Decorative Led Lighting With Extruded Polycarbonate, Environmentalfriendly, Energy Efficient, Easy To Install, Pc Diffuser, High Quality Materials, Pre-Wired Including Providing Pvc Round / Pvc Square Blocks-02 Nos And Connected With Led Fitting To Ceiling Rose Terminal And Incl Removing Old Unserviceable Fitting Complete All As Specified And Directed.Make :-Havells Cat No. Lhexacp7fn1w020or Equivalent Make In Crompton / Philips 130 Supply And Fix Led Secruity Light Fitting Of Capacity 60 Watt Led Street Light Fitting In Aluminium Pdc Housing, Toughened Glass Cover With Ip65 Protectionwith 4 / 5 Kv Inbuilt Surge Protector And Cable Connection From Ceiling Rose / Looping Box / Switch Board / Dbs To Light Fitting And Testing And Including Removing Of Old Unserviceable Item Complete All As Specified And Directed.Make:- Crompton Cat Ref No.Lsts-40-Cdl-M Or Equivalent Make In Havells / Philipsas Approved 131 S & F Energy Efficient And Energy Saving New Generation 10 Watts Led Bulk Head Light Fitting Ip-65 Luminaire With Opel Diffuser Pre-Wired Ofluminaires Including Led Light Driver And Connected With Led Fitting To Ceiling Rose Terminaland Incl Removing Old Unserviceable Fitting Complete All As Specified And Directed. Make :-Havells Cat No. Lhfhdpe1tn1k020 Or Equivalent Make In Crompton / Philips 132 Supply And Fix Gi Bracket Pipe Of Size 32 Mm Dia Medium Grade Of 1.2 Mtr Long Bent To Shape Suitable Degree Of Bending As Per Site Requirementwith Hot Or Coldbending Method Of Process For Making The One End Of Gi Pipe Bracket Suitable For Fixing Of Any Type Street Light Fitting And Shall Be Fixedonwall Surfaces And Including Providingsuitable Fabricate Galvanised Flat Ironclamps Of 30X6 Mm Thick-02 Nossuitable For Fixing At Any Place / Height With Hole Fastners, Nuts, Bolts & Washers Including Grouting On Wall Etc And Including Removing Of Old Unserviceable Item Complete All As Specified And Directed.Make Of Gi Pipe:- Jinadal / Tata / Surya Prakash 133 Supply & Fixingand Sheet Metal Enclosurewith Acrylic Door Type, Double Door , 415 Volts Ac, Vtpndb, 4 Way, 8+12 Modules, Flush Mounting With 200Amps Copper Busbar, 2 Neutral / Earth Bars Links And Mccb Incomer, And Mcb Spn / Sp / Tpnas Outgoing And Complete Forip43&54 Dbs Protection And Includingremoving Old Unserviceable Dbs And Incl Making Good The Disturbed Surfaces To Match With Existing Surface And Colour Shade Complete All As Specified And As Directed.Make:-Legrand Cat No.5077 30 4 Way Or Equivalentmake In Abb / Havells 134 Supply & Fixing Andsheet Metal Enclosure, With Acrylic Door Type, Double Door, 240 Volts Ac, Spn, Db, 8 Way, Flush Mounting With 100Amps Copper Busbar, Neutral Bar, Earth Bar Links And Mcb Incomer Mcb Spn / Dp And Mcb Sp As Outgoingforip 43& Ip54 Dbs Protection Nd Includingremoving Old Unserviceable Dbs And Making Good The Disturbed Surfaces To Match With Existing Surface And Colour Shade Acomplete All As Specified And As Directed. Make:-Legrand Cat No.5076 21 8 Way Or Equivalent Makein Abb / Havells 135 Supply & Fix Andsheet Metal Enclosure, With Acrylic Type Double Door, 240 Volts Ac, Spn, Db, 4 Way, Flush Mounting With 100Amps Copper Busbar, Neutral Bar, Earth Bar And Mcb Incomer, Mcb Spn / Dp, And Mcb Sp As Outgoingforip 43& Ip54 Dbs Protection Nd Includingremoving Old Unserviceable Dbs Making Good The Disturbed Surfaces To Match With Existing Surface And Colour Shade Complete All As Specified And As Directed. Make:-Legrand Cat No.5076 20 4 Way Or Equivalent In Abb / Havells 136 Supply & Fixmcb Sp 6 To 32 Amps 10 Ka, C Series, Ac, 240Volts, 50Hz , Isi Marked And Including Removing Old Unsv Items Complete All As Specified And Directed.Make:- Legrand / Abb / Havells Or As Approved Make 137 Supply & Fix And Mcb Spn 32 To40 Amps 10 Ka, C Series, Ac, 240Volts, 50Hz, Isi Marked And Including Removing Old Unsv Items Complete All As Specified And Directed.Make:- Legrand / Hager / Havells Or As Approved Make 138 M & L For Sub Main Wiring Complete With 2 Run Of 6 Sqmm Single Core Copper Conductor ( Isi Marked ) Cable1100 Volts Grade, Isi Marked, Frlsh Type ( Conforming To Is-694 / 1990 As Amended ) Pvc Insulated, Unsheathed, Flexible, Multi Strandedcolour Coded Cables Drawn Through And Including Rigid Pvc Conduit Concealed Isi Marked Medium Grade ( Mms ) With All Connected Accessories Such Asbend, Tee, Elbow, Short Peices Etc Concealed In Wall / Roofs / Floorsand Including One Run Of 6 Sqmm Single Core Copper Conductor Cable Flexible, Pvc Insulated, Unsheathed, Multistranded, 1100 Volts Grade, Isi Marked Frlsh Type As Earth Continuity Conductor Connected To Common Earth Dolly And Including Removing Old Unsv Sub Main Wiring Andmaking Good The Disturbed Surfaces To Match With Existing Surface And Colour Shade And Complete All As Specified And Directed.Note : - Two Run Of 6 Sqmm Single Core Copper Conductor Cable And One Run Of 6 Sqmm Single Core Copper Conductor Cable As Earth Continuity And One Run Of Pvc Conduit Shall Be Measured As One Unit. 139 Supply And Fixsuitable For Flush Mounting Sheet Steel Enclosure Metal Clad Plug And Socket Including Mcb Sp 20Amps, 10Ka C Series, 230 Volts, 50Hzsuitable For AcS / Geysers Complete All As Specified And Directed.Make:- Legrand / Hager / Havellsor As Equivalent Approved Make 140 Supply And Fixmccb, 63 Amps, 4 Pole, 415 Volts , 16Ka Thermal Magnetic Type With Necessary Lugs, Thimbles, Nuts Bolts And Washersand Including Removing Old Unserviceable Itemcomplete All As Specified And As Directed. Make:- Legrand / Hager / Havellsor As Equivalent Approved 141 Taking Down Old Unserviceable Ceiling Fan Of Any Type / Sizefrom Existing Location And Deposit In Mes Store Yard And Supply And Fix Ceiling Fan Of Size 1200 Mm Sweep, High Speed, Single Phase, 240Volts, Ac, 50Hz, Bee Not Lessthen 5 Star Ratedas Approved Colour And Including Hanging Gi, D Hook For Hanging With Fastners Heavy Dutywith Necessary Connectingaccessories And Testing Complete All As Specified And Directed.Make:-Havells ( Es-50 ) Or Equivalent In Orient / Kaithan / Atomberg As Approved Make Note:- Contractorwill Be Write In Mes No / Ca No With Date 142 Taking Down Old Unserviceable Exhaust Fans Of Any Type / Sweep From Work Site And Deposit To Mes Store Yard Supply And Fix New Exhaust Fan, Steel / Pvc Body Ac Single Phase.230Volts Of Size 300 Mm Sweep With Bladesand Including Providing Insect Protection Net Frame , With Louvers And Frameincl Writing Mes No On Exhaust Fan With Synthetic Enamel Paint Complete All As Specified And Directedcomplete All As Specified And Directed. Make:-Atomberg / Havells / Crompton Or As Approved Make 143 Taking Down Old Unserviceable Wall Fans Of Any Type / Sweep From Work Site And Deposit To Mes Store Yard For Safe Custody Andsupply And Fix Wall Fan 230Volts, Single Phase, Oscillating Type, 450 Mm Sweep, Hi-Speed, Low Noisewith Blades And Outer Cover And Including Providing Hanging Hook And Connected Items Incl Writing Mes No On Wall Fan With Synthetic Enamel Paint Complete All As Specified And Directedcomplete All As Specified And Directed.Make:- Havells / Usha / Crompton 144 Taking Down Old Unserviceable Geyses Of Any Capacity From Work Site At Any Height And Deposit To Mes Store Yard For Safe Custodyand Supply And Fix New Electric Water Heater, Storage Type Steel Body / Plastic Body With Copper Inner Tank And Heating Element Upto2 Kw Capacity 25 Litres, Bee 5 Star Rated Complete With All Accessories Such As Safety Valve, Thermostat, Nrv, Hot Waterand Cold Waterheavy Duty Connection Pipes-02 Nos, Holefasterns 02 / 04 Nosand Necessary Accessories As Per Site Requirement Etc.Complete All As Specified And Directed.Make:- Havells / Crompton / Racold / Venus 145 Supplying And Laying Of Cpvc / Upvc Pipes Sdr 11 & Plain Sdr 11 Incl Allfittings Of Outer Dia 16 Mmon Walls / Ceiling Or Laying In Floors Andincl Removing Old Unsv Items Complete All As Specified 146 Supply And Fixingstop Valvestandard Of Ptmtany Colour High Pressure Screwed , For Iron Pipe Or Cpvc / Upvc And Fixed Minium Weight 15 Mm-90Gms Andincl Removing Old Unsv Items Complete All As Specified 147 Supply And Fixing Bib Taps, Cast Copper Alloy Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For 15 Mm Dia Iron Or Pvc Pipes Or For Unions And Fixed Andincl Removing Old Unsv Items Complete All As Specified 148 Material And Labour For Pvc Insulated, Lt Armoured Electric Cable With Aluminium Standed Conductor 1100 Volts Grade, Cross-Sectional Area 25 Sqmm , 4 Core Laid In Trenches / Pipes / Ducts / Wall / Boarings With Necessary Cable Lugs And Glands, Nuts, Bolts And Washers, Saddeling On Wall Properly Etc And Testingand Including Removing Old Unsv Ug Cables Complete All As Specified And Directed. 149 Material And Labour For Xlpe Insulated, Lt Armoured Electric Cable With Aluminium Standed Conductor 1100 Volts Grade, Cross-Sectional Area 6 Sqmm , 2 Core Laid In Trenches / Pipes / Ducts / Wall / Boarings With Necessary Cable Lugs And Glands, Nuts, Bolts And Washers, Saddeling On Wall Properly Etc And Testingand Including Removing Old Unsv Ug Cables Complete All As Specified And Directed. 150 Supply And Fix20 Watts Led Post Top Lantern Made In Cast Aluminium Spigot Housing With Decorative Opal Polycarbonate Diffser And Ip65 Protectionand Providing Suitable Fixing Arrangements Such As Necessary Gi Pipe At Post Top / Pillar And Civil Work, Lugs, Glands, Nuts, Bolts And Washers Andincluding Removing Old Unserviceable Itemcomplete All As Specified And Directed. Make :-Crompton Cat Ref:Lpth-20-Cdl Or Equivalent In Havells / Bajaj / Philips As Approved 151 Boaring Holes Horizontally Under Road Without Damaging The Surface Of Road ( Minimum 1.0 Mtr Bellow The Road Surface ) With The Help Of Gi Tubing Of Any Dia Not Exc 80Mm Dia For Passing Of Ug Cable All As Specified And As Directed. 152 Material And Labour For Pcc 1:2:4 Type B1 Using ( 20 Mm Graded Stone Aggregate ) For Making Good Cutting Portioncoping Of Pole And Filling Of Foundation Etc Including Necessary Use And Waste Of Form Work Complete All As Specified And Directed.Note:- Top Surface Of Pole Coping To Making Smooth Finishing And White Washingmade By The Contractor Costdeemed Intoquoted Rete Only. 153 Supply And Filling In And Speading Unwashed River Sand For Cushioning And Covering The Under Ground Cables In Trenches And Punning To Provide Required Cover Complete All As Specified In Ssr Part-I And As Directed. 154 Excavation In Trenches Not Exceeding 1.5 Mtr Wide And Not Exc 1.5 Mtr Depth For Laying Of Cables, Pipe Lines, Protection Pipes And Foundations Etc And Getting Out In Soft Loose Soil Complete All Asspecified And Directed. 155 Returning Filling In Soil Including Spreading Leveling Watering And Well Rammimg In Layer N Exc 25 Cm Complete All As Specified And Directed 156 Removing Excavated Soil Not Exc50 Mtr Ant Depositing Where Directed At A Level Not Exc 1.5 Mtr Above The Starting Point All As Specified And Directed 157 M & L For Brick Sub Class B 250Mm X 115Mm X 0.75Mm And Laid In Trenches As In Protection Of Ug Cablecomplete All As Specified And Directed. 158 Material & Labour For Gi Pipe 50 Mm Light Grade Laid In Trenches Floors / On , Pole / Road For Cable Protection With All Fittings Complete All As Specified And Directed.Make:- Jindal / Tata / Swastik / Bst 159 Material And Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600Mmx 600Mmx 6Mm Thick Buried Directely In Ground Vertically ( Earth Pit Not Less Than 2.25 Meters Deep Below Ground Level ) With Top Edge Of Plate Not Less Than 1.5 Metres Belowground Level, Connected To And Including Galvanised Iron Wire 4 Mm Dia And Light Grade Protection Pipeof 15 Mm Diafrom Earth Electrode Up To Test Point Or Up To 7.5Mtr Whichever Is Less By Means Of Gibolts, Nuts, Check Nuts And Washersall As Per Electrical Plate No 3 Of Ssr Pt-I And Gi Watering Pipe Of 20 Mm Dia Medium Grade, Gi Funnel With Wire Mesh, Including Charcoal, Salt Packed All Around The Earth Electrode Plate In Layers, Pcc Earth Pit Chamber 1:3:6 Type C1, Of Size 45X 45X 45 Cm, Rcc / ( Pvc Hevy Duty Cover ) Cover 1:2:4 Type B1 Of Size 45X45x6cm, Excavation / Earth Work In Any Strata And Returning Filling, Removal Of Surplus Soil And Testing / Test Point For Required Valueincluding Removing Old Item Completeall As Specified And Directed.