Tender For Repair To Certain Buildings Under Age B/R-Ii, Ge (Af) No. 2 Jodhpur., jodhpur-Rajasthan

Military Engineer Services-MES has published Tender For Repair To Certain Buildings Under Age B/R-Ii, Ge (Af) No. 2 Jodhpur.. Submission Date for this Tender is 03-01-2024. Building Work Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

41114896
Corrigendum : Tender For Repair To Certain Buildings Under Age B/R-Ii, Ge (Af) No. 2 Jodhpur.
Open Tender
Indian
Rajasthan
jodhpur
03-01-2024

Tender Details

Tender For Repair To Certain Buildings Under Age B / R-Ii, Ge ( Af ) No. 2 Jodhpur. ; 1 M&L For Demolitation Of Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Providedfor And Complete All As Specified. 2 M&L For Cement Concrete Type B-1, 75 Mm Thick 1:2:4 ( 20Mm Graded Aggregate ) For Finishing Cement Concrete Surface Even And Smooth Without Using Extra Cementfor Plinth Protection, Path And Complete All As Specified. 3 M&L For Machine Pressed Pecast Cement Concrete Interlocking Paver Paver Block Any Shape And Sze Confirming To Is 15658-2006 Of 60 Mm Thickness In M-30 Grade With Grey Cement And Pigment And Complete All As Specified. 4 M&L Cement Concrete Type D-2, 75 Mm Thick 1:4:8 ( 40 Mm Graded Aggregate ) And Complete All As Specified. 5 M&L For Sand Filling Under Floors Or In Foundations Including Watering And Consolidation And Complete All As Specified. 6 M&L For Dismantling Floor Heart Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) And Rubbish Off The Premises And Com [ Plete All As Specified. 7 M&L Cement Concrete Type B-0, 25 Mm Thick 1:2:4 ( 12.5Mm Graded Aggregate ) 8 M&L For Coloured Non Skid Coloured Ceramic Tiles 7 To 8Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.11 But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Thick Over Cement Screed 15Mm Thick In Cement Mortor 1:6 Laid And Jointed Complete 9 M&L For Coloured Glazed Ceramic Coloured Tilesof Size 350X 250X 7Mm / 450X350x7mm Thick On Walls / Vertical Surfaces Including 10Mm Thick Rendering In Cm 1:4, All As Directed. 10 M&L For Coloured Vitrfifed Cermaic Tiles 10 Mm Thick Area Of Each Tiles Not Less Than 0.36 Sqm In Floors Etc Set & Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15 Mm Thick Screed Bed Or Bedding Layer In Cm 1;6 As Directed By Engineer-In-Charge 11 All As Per Item No. 10Above But On Vertical Surfaces Such As Dados Skirting And Risers To Step Set & Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 10 Mm Thick Renedering In Cm 1:4 On Stone Masonary Surfacesas Directed By Engineer-In-Charge 12 M&L For Machine Cut Kota Stone Slab Flooring 20-25 Mm Thick Over 15 Mm Thick Screedin Cm 1:6 And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 13 M&L For Machine Cut Kota Stone Slab20-25 Mm Thick On Skirting, Dado Over 10 Mm Thick Renderingin Cm 1:6 And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 14 M&L Taking Down Cement Or Cement Lime Plaster Of Any Description On Brick Or Stone Walls Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Etc And Complete All As Specified 15 M& L For 15 Mm Thick Rendering On Stone Masonary In Cm 1:4 On Ceilings On A Floating / Setting Coat For Additional Thickness Using Integral Water Proofing Compound , Finished Even And Smooth Without Using Extra Cement Andall As Specified. Note:- Water Proofing Compound Shall Be Measured And Paid Seperately 16 M& L For 15 Mm Thick Rendering On Stone Masonary In Cm 1:6 On Internal Wallsusing , Finished Even And Smooth Without Using Extra Cement Complete All As Specified. 17 M& L For 15 Mm Thick Rendering On Stone Masonary In Cm 1:4 On External Wallsusing Integral Water Proofing Compound @3% Weight Of Cement , Finished Even And Smooth Without Using Extra Cement Complete All As Specified. Note:- Water Proofing Compound Shall Be Measured And Paid Seperatly ) 18 M&L For Complete Removal Of Existing Treatment Of Walls And Applying Two Coats Of Oil Bound Distemper Over A Coat Of Primer, White Or Tinted, All As Directed. 19 M&L For Complete Removal Of Existing Treatment Of Walls And Applying One Coats Of Oil Bound Distemper Over A Coat Of Primer, White Or Tinted, All As Directed. 20 M&L For Preperation Of Plastered And Unplastered New Surface Of Walls And Applying Two Coats Of Oil Bound Distemper Over A Coat Of Primer, White Or Tinted, All As Directed. 21 M&L For Complete Removal Of Existing Treatment Of Walls And Applying Two Coats Of White Wash And Complete All As Directed. 22 M&L For Preparation Of New Plastered Or Unplastered Surfaces Of Ceilings And Applying Two Coats Of White Completeall As Directed. 23 M&L For Complete Removal Of Existing Treatment Of Ceilings And Applying Two Coats Of White Washoverand , All As Directed. 24 M&L For Complete Removal Of Existing Treatment Of Ceilings And Applying One Coats Of White Wash Overand , All As Directed. 25 M&L For Preparation Of New Plastered Or Unplastered Surfaces Of Walls And Applying Two Coats Of Cement Base Paint Over A Coat Of Primer, White Or Tinted, All As Directed. 26 M&L For Complete Removal Of Existing Treatment Of Walls And Applying One Coats Of Cement Base Paint Over A Coat Of Primer, White Or Tinted, All As Directed. 27 M&L For 50 Mm Thick ( Average ) Cement Concrete 1:3:6 Type C-0 Mix ( 12.5 Mm Graded Stone Aggregate ) In Padding Over Roof. 28 Taking Down Old Existing Roof Treatment ( App Membrane & Plaster ) And Removing Outside Mod And Cleaningof Roof Slab / Chajjas Sweepingwith Brooms Removing All Loose Materials Debris Etc Complete All As Specified And As Directed By Engr-In-Charge 29 M&L10 Mm Thick Screed Bed With Cm 1:4With Water Proofing Compound @ 3% By Weight Of Cementfinish Even And Smooth Surfaces Using Without Extra Cement. Water Proofing Compound Shall Be Measured And Paid Seperately 30 M&L For Providing App Based Polymeric Membrane Minimum Weighing 3Kg / Sqm And Minimum 3 Mm Thick Reinforced With Polyster Non Woven Fabric ( Wt. Not Less Than 150 Gms / Sqm ) Over On Primed Surfaced @ 0.5 Ltr / Sqm By Torched Application And Complete All As Specified And As Directed By Engr-In-Charge ( Note : Quoted Rate Shall Deemed To Be Included For Work In Building / Structure Of Any Height ) 31 S&F In Repairs S&F In Repairs Vitreous- China Wash Down Water Closet Squatting Pan ( Orissa Pattern ) Size 580 X 440 Mm Incl Pvc P-Trap, And Fixing Arrangementincluding Pcc For Fixing Complete All As Specified And As Directed. 32 S&F In Repairs Vitreous- Vitreous China Ewc Wash Down Water Closet Pan ( Pedestal Pattern ) , White ( Excluding Flushing Cistern And Flush Pipe ) Including All Fixing Arrangement Complete All As Specified And Directed. 33 S&F In Repairs Of Flushing Cistern Pvc 10 Ltrs Cap Valve Less Syphonic Action Type, Low Level White With Intel , Ball Valve , Float Incl Brackets Andpvc Flush Pipe 32Mm Dia Complete All As Specified. 34 S&F In Repairs Health Faucet Cp Mild Steel Chromium Plated Suitable For 15 Mm Dia Pipe With 1.25 Mtr Long Flexble Tube Cp Wall Hook Including Making Connections And Fixed Complete In All Respect As Specified 35 Taking Upor Down Steel Tubing And Connection Including Cleaning For Refixing Or Removal To Store Yard Of Bore 15 Mm. 36 Taking Upor Down Steel Tubing And Connection Including Cleaning For Refixing Or Removal To Store Yard Of Bore 20 Mm. 37 S & F 15 Mm Dia Galvanized Steel Tubing, Medium Grade, With All Fitting And Fixed Complete To Walls Celling Or Laid In Floors All As Specified And Directed. 38 S & F 20 Mm Dia Galvanized Steel Tubing, Medium Grade, With All Fitting And Fixed Complete To Walls Celling Or Laid In Floors All As Specified And Directed. 39 S&F In Repair Gun Metal Globe Or Gate Valveswith Iron Wheel Head, Screwed Both Ends For Iron Pipe Of 20 Mm Dia. 40 S&Fin Repair Vitreous China Whb White, Flat Back, Size 550 X 400 Mmincluding Brackets. Vitreous China ( Flat Black Or Angle Back Type ) Any Size, Including Cutting For And Pinning In Ends Of Brackets Or Erecting Stand But Exclusive Of Fixing Of Supply And Waste Pipe, All As Specified And Directed. 41 S&F In Repairs Urinal, Bowl Type Or Half Stall Pattern, ( Excluding Flushing Cistern And Flush Pipe ) But Including Waste Pipe Fixed As In Repair Complete All As Specified. 42 S&F In Repair 15 Mm Angle / Stop Valve, Fancy Type, Chromium Plated With Screwed Down High Pressure With Crutch Or Butterfly Handle Screwed Both Ends For Iron Pipe Complete All As Specified And Directed. 43 S&F As In Repair 15 Mm Angle / Stop Valve, Fancy Type, Chromium Plated With Long Shank And Cup ( Concealed Type ) Screwed Down High Pressure With Crutch Or Butterfly Handle Screwed Both Ends For Iron Pipe Complete All As Specified And Directed. 44 S&F In Repair 15Mm Bib Taps Cast Copper Alloy Cp With Crutch Or Butterfly Handle Screwed Down For Iron Pipe Or For Brass Ferrule All As Specified And Directed. 45 S & F In Repair 15 Mm Pillar Tap Cast Copper Aloy With Capston Heads Chromium Plated Screwed Down Fly Nuts Screwed For Iron Pipe Or For Brass Ferrule And Fixed Complete All As Specified. 46 S&F In Repairs 15 Mm Bore Two- In- One Bib Taps, Cast Copper Alloy, Chromium Plated, With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule. 47 S&F In Repair Brass Chromium Plated Shower Rose 125Mm Size All As Specified And Directed. 48 S&F In Repairs Pvc Connections 15Mm Size With Ptmt Nuts Of Length 450Mm All As Specified And Directed. 49 S & F In Repairs Pvc Waste Pipe 32Mm Bore And 1000 / 900 Mm Long For Whb All As Specified And As Directed 50 S&F In Repair Cp Soap Dish, Fixed To Plugs With Chromium Plated Screws And All As Specified. 51 S&F In Repair Cp Grating 100 Mm Dia All As Specified And As Directed. 52 S&F In Repair Cp Tubular Towel Rail, 20 Mm Dia, D Type, 60 Cm Long Between Flanges And All As Specified 53 S&F In Repair Shelf Of Ptmt Fixed With And Including Chromium Plated Brass Screws And Wooden / Plastic Cleats ( Minimum Weight 300 Gms ) And All As Specified And As Directed. 54 S & F Plastic Water Closet Seat Cover, Black Or White, Closed Pattern With Flat Bottom, And Cover And Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified. 55 S & F In Repair Mirror Of Selected Quality Glass Of 5 Mm Thick Mounted On 6 Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers All As Specified And As Directed 56 M & L For Disconnecting Existing Tanks Of Any Capacity, Setting Aside ( Or Lowering If Required ) For Repairs, Cleaning, Etc. And Hoisting If Required Reconnecting And Re-Fixing In Position. ( Cleaning Repairing, Etc. Measured Separately ) 57 Dismantling Of Existing Water Tank ( Pvc / Rcc / Ac ) N Exc 500 Ltr Capcity And Removing From Site Complete As Directed By Engr -In-Charge. 58 Dismantling Of Existing Water Tank ( Pvc / Rcc / Ac ) Exc 500 Ltr But N Exc 1000 Ltr Capcity And Removing From Site Complete As Directed By Engr -In-Charge. 59 S&F 500 Ltr Capacity Rotational Moulded Polyethylene Water Storage Tanks ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position Incl 20Mm Bore Ball Ptmt. Valve High Pressure With Polythyne Float And Flynut Complete In Repair. 60 S&F 1000 Ltr Capacity Rotational Moulded Polyethylene Water Storage Tanks ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position Incl 20Mm Bore Ball Ptmt. Valve High Pressure With Polythyne Float And Flynut Complete In Repair. 61 Demolition And Breaking Up Drain Pipes ( Salt Glazed Ware, Ac Or Reinforced Concrete ) Set In Cement Mortar Of 100 Mm Dia 62 S&F Pvc ( Swr ) Pipes 110 Mm Dia Single Socketed, In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors 63 S&F Pvc ( Swr ) Pipes 110 Mm Dia Single Socketed, In Any Length With Rubber Ring Joints Fixed In Walls Including Brackets And Complete All As Specified. 64 S&F Pvc ( Swr ) , Junction Single, ( Single T ) With Acess Door 110 Mm Dia Equal Or Unequal 65 S&Fpvc ( Swr ) Door Bends 110 Mm Dia 66 S&F Pvc ( Swr ) Vent Cowl 110 Mm Dia 67 S&Fpvc ( Swr ) S Trap 110 Mm Dia 68 S&F Pvc ( Swr ) Pipes 75 Mm Dia Single Socketed, In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors 69 S&F Pvc ( Swr ) Pipes 75 Mm Dia Single Socketed, In Any Length With Rubber Ring Joints Fixed In Walls Including Brackets And Complete All As Specified. 70 S&F Pvc ( Swr ) , Junction Single, ( Single T ) With Acess Door 75 Mm Dia Equal Or Unequal 71 S&Fpvc ( Swr ) Door Bends 75 Mm Dia 72 S&F Pvc ( Swr ) Vent Cowl 75 Mm Dia 73 S&F Pvc ( Swr ) Floor Trap Of Outlet Dia 75Mm Incl Jointing With Solvent Cement 74 S & F In Repairs 100 Mm Stack Clamps Out Of 50 Mm By 5 Mm Flat Iron And 16Mm Dia Round Iron Stays, Including Bolts And Nuts And Securing Ends Of Stays To Wall Or Roof All As Specified & Directed. 75 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frames ) Not Exceeding 1.5 Sqmeach And Removing From Site.Note-Quoted Rate Shall Be Deemed To Be Include For Cutting Holes / Demolition Of Pcc Blocks Etc For Taking Down Chowkats And Making Good The Damaged Surfaces In Cm 1:3 All As Directed. 76 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frames ) Exceeding 1.5 Sqmeach But N.Exc 4.5 Sqm Eachand Removing From Site.Note-Quoted Rate Shall Be Deemed To Be Include For Cutting Holes / Demolition Of Pcc Blocks Etc For Taking Down Chowkats And Making Good The Damaged Surfaces In Cm 1:3 All As Directed. 77 Taking Down Shutterof Any Discription Exc 1 Sq. M And N Exc 2 Sq. M Each And Removing From Site Complete All As Specified. 78 M&L Pcc 1:3:6 Type C1 Using 20 Mm Graded Stone Aggregate As In Bed Blocks Etc For Embedding Hold Fasts Complete All As Specified And Directed By Engineer-In-Charge 79 Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specified And Directed 80 S&F Factory Made Solid Panel Pvcdoor Shutter 30Mm Thick ( Style ) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails, M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc `C Channel Heaving A Pvc Sheet Strip Of 20Mm Width Suck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S Frame Wedded / Sealed To The Stiles, & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Supplying & Fixing In The Frame At Site As Per Specified And Directed 81 S&F Steel Windows With Side Hung Shutters Including Projecting Type Hinges With Steel Handle And Steel Peg Stay, Complete With Glazing Bars Dovetailed Or Welded Complete. 82 S&F Steel Windows With Side Hung Shutters Including Projecting Type Hinges With Steel Handle And Steel Peg Stay, Complete With Out Glazing Bars Dovetailed Or Welded Complete. 83 M&L For Powder Coated Anodised Aluminium Frame For Door Window & Ventilator With One Or More Rebates Including Joining Cleat For Fixing Etc Comlete All As Specified. 84 S&F Metalic Louvers Slits To Hold Glass Strip Of Size 300X500 Mm With Including Arrangement Of Fixing Glass Pinhead As Per Size & Louvers Ventilator ( Glass Shall Be Measurement Separately ) Complete All As Specified And As Diredcted. 85 S&F 35 Mm Thick Factory Made, Second Class Hard Wood, Plain Framed, Panelled Shutter ( Two Panel ) With Lock Rail And Panel Of 9 Mm B.W.P. Commercial Ply Or 12 Mm Veneered Particle Board With Commercial Veneering On Both Faces. The Size Of Rail And Stile As Per Is: 1003 ( Part I ) , Kiln Seasoned And Chemically Pressure Treated. 86 M / L For Glazed And Skeleton Shutters Of Thickness 35Mm Of Iind Class Hard Wood , Open Rebated And Prepared To Receive Glass, Gauze, Etc. ( Without Sash Bars ) , Edge Of Framing Plain, Chamfered Or Rounded, Fitted With Cut And Mitred Beds For Securing Glass, Etc.; Sizes Of Members Of Shutters As Specified In Ssr Part I, Section 8. Clause 8.24 ( A ) ; Supplied And Fitted To Chowkats Note: Glazed Or Clothetc In Panelsor Sash Square Shall Be Measured Seperately 87 S&Faluminium Anodised Barrel Tower Bolt Of Extruded Section 150Mm Size 88 S&F Aluminium Anodised Barrel Tower Bolt Of Extruded Section 200 Mm Size 89 S&F Butt Hinges 100 Mm, Extruded Aluminium Alloy With Galvanised Mild Steel Hinge Pin, Anodised And Fixed 90 S&F Butt Hinges, Heavy Weight Cold Rolled Mild Steel Ofsize 125Mm. 91 S&F Extructed Aluminium Alloy Handles, Fabricated Type, Anodised Of Size 150 Mm. 92 S & F In Repairs Aluminium Alloy, Anodised, 300Mm Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed 93 S & F Aluminium Alloy, Anodised, 300Mm Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed 94 S&F In Repairs Galvanised Mild Steel Wire Cloth, 0.56 Nominal Dia Of Wire And Average Width Of Aperture 1.00 Mm And Fixed With Tinned Tacks Or Galvanised Wire Staples 95 S&F In Galvanised Mild Steel Wire Cloth, 0.56 Nominal Dia Of Wire And Average Width Of Aperture 1.00 Mm And Fixed With Tinned Tacks Or Galvanised Wire Staples 96 S&F In Repair Ms 300 Mm , Ordinary Rat Tail Rod Pattern Springs Including Rooler And Roller Plate Complete All As Specified. 97 S&F Ms 300 Mm , Ordinary Rat Tail Rod Pattern Springs Including Rooler And Roller Plate Complete All As Specified. 98 M&L For Hacking Out Old Broken Glass ( Any Thickness, Size, Quality Or Description ) From Metal Frame Glazed With Putty Including Punching Or Drilling Out Old Glazing Pin / Spring, Clips And Providing New Ones. 99 S&F Figured Sheet Glass 3 Mm Thick, Ordinary Quality And Glazing With Oil Putty In Square N.Exc. 0.5 Sqm In Each Paneand Complete All As Specified. 100 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frames ) Not Exceeding 1.5 Sqmeach And Refixing In Same Opening And Complete..Note-Quoted Rate Shall Be Deemed To Be Include For Cutting Holes / Demolition Of Pcc Blocks Etc For Taking Down Chowkats And Making Good The Damaged Surfaces In Cm 1:3 All As Directed. 101 Resecuring Or Easing & Adjusting Without Taking Down Shutters Of Any Descriptionexc. 1 Sqm Butn. Exc. 2 Sqm Each. 102 M&L Providing And Injecting Chemical Emulsion For Post Constructional Antitermite Treatment Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion At The Rate Of 7.5 Litres Per Square Metre Of Vertical Surface To A Depth Of 300 Mm Including Channel Along The Wall And Rodding Etc. Complete All As Specified And Directed 103 M&L For Framed Work Such As Grills, Grating Etc. With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes ; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railing Framework Of Water Tanks And Similar Work Conforming To Fe290.Gde-E-165 And Complete All As Specified. 104 Demolition Of Stone / Boulder Masonry, Built In Cement Mortar Including All Quoins, Arches, Pillars, Etc. And Removing From Site All As Specified And Directed. 105 M&L For Squared Rubble Walling, Jodhpur Type Brought Upto Courses, Well Bonded, Bedded And Solidly Hearted, Built In Cement Mortar 1:4 And Complete All As Specified And Directed. 106 M&L For Preparation Of Old Painted Wooden Surface Of Any Description Not Otherwise Provided Over 10 Cm Width Or Girth And Applying One Coats Of Synthetic Enamel Paintand Complete. 107 M&L For Preparation Of New Wooden Surface Of Any Description Not Otherwise Provided Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer And Complete. 108 M&L For Preparation Of Old Painted Steel Surface Of Any Description Not Otherwise Provided Over 10 Cm Width Or Girth And Applying One Coats Of Synthetic Enamel Paintand Complete. 109 M&L For Preparation Of New Steel Surface Of Any Description Not Otherwise Provided Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide And Complete. 110 M&L For Preperation Of Plastered And Unplastered Surface Of Walls And Applying Two Coats Of Wheather Proof Extrerior Emulsion Paintcomplete All As Specified All As Directed. 111 Supply Only Integral Water Proofing Compound ( Isi Marked ) .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work : Repair to certain bldgs under AGE B/R-II, GE (AF) No. 2 Jodhpur
Sl. No. Item Description
1M&L for demolitation of cement concrete of any description and in any position not otherwise specifically providedfor and complete all as specified.
2M&L for cement concrete type B-1, 75 mm thick 1:2:4 (20mm graded aggregate) for finishing cement concrete surface even and smooth without using extra cementfor plinth protection, path and complete all as specified.
3M&L for Machine pressed pecast cement concrete interlocking paver paver block any shape and sze confirming to IS 15658-2006 of 60 mm thickness in M-30 grade with grey cement and pigment and complete all as specified.
4M&L Cement concrete type D-2, 75 mm thick 1:4:8 (40 mm graded aggregate) and complete all as specified.
5M&L for sand filling under floors or in foundations including watering and consolidation and complete all as specified.
6M&L for dismantling floor heart or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises and com[plete all as specified.
7M&L Cement concrete type B-0, 25 mm thick 1:2:4 (12.5mm graded aggregate)
8M&L for coloured Non Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match thick over cement screed 15mm thick in cement mortor 1:6 laid and jointed complete
9M&L for coloured glazed ceramic coloured tilesof size 350x 250x 7mm/450x350x7mm thick on walls/vertical surfaces including 10mm thick rendering in CM 1:4, all as directed.
10M&L for coloured vitrfifed cermaic tiles 10 mm thick area of each tiles not less than 0.36 sqm in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1;6 as directed by Engineer-in-Charge
11All as per item no. 10above but on vertical surfaces such as dados skirting and risers to step set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick renedering in CM 1:4 on stone masonary surfacesas directed by Engineer-in-Charge
12M&L for machine cut Kota stone slab flooring 20-25 mm thick over 15 mm thick screedin CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
13M&L for machine cut Kota stone slab20-25 mm thick on skirting, dado over 10 mm thick renderingin CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
14M&L Taking down cement or cement lime plaster of any description on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc and complete all as specified
15M& L for 15 mm thick rendering on stone masonary in CM 1:4 on Ceilings on a floating/setting coat for additional thickness using integral water proofing compound , finished even and smooth without using extra cement andall as specified. Note:- Water proofing compound shall be measured and paid seperately
16M& L for 15 mm thick rendering on stone masonary in CM 1:6 on internal wallsusing , finished even and smooth without using extra cement complete all as specified.
17M& L for 15 mm thick rendering on stone masonary in CM 1:4 on external wallsusing integral water proofing compound @3% weight of cement , finished even and smooth without using extra cement complete all as specified. Note:- water proofing compound shall be measured and paid seperatly)
18M&L for complete removal of existing treatment of walls and applying two coats of oil bound distemper over a coat of primer, white or tinted, all as directed.
19M&L for complete removal of existing treatment of walls and applying one coats of oil bound distemper over a coat of primer, white or tinted, all as directed.
20M&L for preperation of plastered and unplastered new surface of walls and applying two coats of oil bound distemper over a coat of primer, white or tinted, all as directed.
21M&L for complete removal of existing treatment of walls and applying two coats of white wash and complete all as directed.
22M&L for preparation of new plastered or unplastered surfaces of Ceilings and applying two coats of white completeall as directed.
23M&L for complete removal of existing treatment of ceilings and applying two coats of white washoverand , all as directed.
24M&L for complete removal of existing treatment of ceilings and applying one coats of white wash overand , all as directed.
25M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of primer, white or tinted, all as directed.
26M&L for complete removal of existing treatment of walls and applying one coats of cement base paint over a coat of primer, white or tinted, all as directed.
27M&L for 50 mm thick (average) cement concrete 1:3:6 type C-0 mix (12.5 mm graded stone aggregate) in padding over roof.
28Taking down old existing roof treatment (APP membrane & plaster ) and removing outside MOD and cleaningof roof slab / chajjas sweepingwith brooms removing all loose materials debris etc complete all as specified and as directed by Engr-in-charge
29M&L10 mm thick screed bed with CM 1:4with water proofing compound @ 3% by weight of cementfinish even and smooth surfaces using without extra cement. Water proofing compound shall be measured and paid seperately
30M&L for providing APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3 mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) over on primed surfaced @ 0.5 Ltr/sqm by torched application and complete all as specified and as directed by Engr-in-charge (Note : Quoted rate shall deemed to be included for work in building / structure of any height)
31S&F in repairs S&F in repairs vitreous- China wash down water closet Squatting pan ( Orissa Pattern) size 580 x 440 mm incl PVC P-trap,and fixing arrangementincluding PCC for fixing complete all as specified and as directed.
32S&F in repairs vitreous- Vitreous China EWC wash down water closet pan (pedestal pattern), white (excluding flushing cistern and flush pipe) including all fixing arrangement complete all as specified and directed.
33S&F in repairs of flushing cistern PVC 10 ltrs cap valve less syphonic action type, low level white with intel , ball valve , float incl brackets andPVC flush pipe 32mm dia complete all as specified.
34S&F in repairs health faucet CP mild steel chromium plated suitable for 15 mm dia pipe with 1.25 mtr long flexble tube CP wall hook including making connections and fixed complete in all respect as specified
35Taking upor down steel tubing and connection including cleaning for refixing or removal to store yard of bore 15 mm.
36Taking upor down steel tubing and connection including cleaning for refixing or removal to store yard of bore 20 mm.
37S & F 15 mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors all as specified and directed.
38S & F 20 mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors all as specified and directed.
39S&F in repair Gun metal globe or gate valveswith iron wheel head, screwed both ends for iron pipe of 20 mm dia.
40S&Fin repair vitreous china WHB white,flat back, size 550 x 400 mmincluding brackets. vitreous china(flat black or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, all as specified and directed.
41S&F in repairs urinal, bowl type or half stall pattern, (excluding flushing cistern and flush pipe) but including waste pipe fixed as in repair complete all as specified.
42S&F in repair 15 mm angle/stop valve, fancy type,chromium plated with screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed.
43S&F as in repair 15 mm angle/stop valve, fancy type,chromium plated with long shank and cup (Concealed type) screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed.
44S&F in repair 15mm bib taps cast copper alloy CP with crutch or butterfly handle screwed down for iron pipe or for brass ferrule all as specified and directed.
45S & F in repair 15 mm pillar tap cast copper aloy with capston heads chromium plated screwed down fly nuts screwed for iron pipe or for brass ferrule and fixed complete all as specified.
46S&F in repairs 15 mm bore two- in- one bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
47S&F in repair Brass chromium plated shower rose 125mm size all as specified and directed.
48S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm all as specified and directed.
49S & F in repairs PVC waste pipe 32mm bore and 1000/900 mm long for WHB all as specified and as directed
50S&F in repair CP soap dish, fixed to plugs with chromium plated screws and all as specified.
51S&F in repair CP grating 100 mm dia all as specified and as directed.
52S&F in repair CP tubular towel rail, 20 mm dia, D type, 60 cm long between flanges and all as specified
53S&F in repair shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 300 gms) and all as specified and as directed.
54S & F Plastic water closet seat cover, black or white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified.
55S & F in repair mirror of selected quality glass of 5 mm thick mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and as directed
56M & L for disconnecting existing tanks of any capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
57Dismantling of existing water tank (PVC/RCC/AC) n exc 500 ltr capcity and removing from site complete as directed by Engr -in-charge.
58Dismantling of existing water tank (PVC/RCC/AC) exc 500 ltr but n exc 1000 ltr capcity and removing from site complete as directed by Engr -in-charge.
59S&F 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl 20mm bore ball PTMT. valve high pressure with polythyne float and flynut complete in repair.
60S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl 20mm bore ball PTMT. valve high pressure with polythyne float and flynut complete in repair.
61Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 100 mm dia
62S&F PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors
63S&F PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints fixed in walls including brackets and complete all as specified.
64S&F PVC (SWR), junction single, (Single T) with acess door 110 mm dia equal or unequal
65S&FPVC (SWR) door bends 110 mm dia
66S&F PVC (SWR)Vent Cowl 110 mm dia
67S&FPVC (SWR) "S" trap 110 mm dia
68S&F PVC (SWR) pipes 75 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors
69S&F PVC (SWR) pipes 75 mm dia single socketed, in any length with rubber ring joints fixed in walls including brackets and complete all as specified.
70S&F PVC (SWR), junction single, (Single T) with acess door 75 mm dia equal or unequal
71S&FPVC (SWR) door bends 75 mm dia
72S&F PVC (SWR)Vent Cowl 75 mm dia
73S&F PVC (SWR) floor trap of outlet dia 75mm incl jointing with solvent cement
74S & F in repairs 100 mm Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof all as specified & directed.
75Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqmeach and removing from site.Note-Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
76Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqmeach but n.exc 4.5 sqm eachand removing from site.Note-Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
77Taking down shutterof any discription exc 1 sq. m and n exc 2 sq. m each and removing from site complete all as specified.
78M&L PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in bed blocks etc for embedding hold fasts complete all as specified and directed by Engineer-in-Charge
79Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specified and directed
80S&F Factory made solid panel PVCdoor shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C" channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specified and directed
81S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars dovetailed or welded complete.
82S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with out glazing bars dovetailed or welded complete.
83M&L for powder coated anodised aluminium frame for door window & ventilator with one or more rebates including joining cleat for fixing etc comlete all as specified.
84S&F metalic louvers slits to hold glass strip of size 300x500 mm with including arrangement of fixing glass pinhead as per size & louvers ventilator (Glass shall be measurement separately) complete all as specified and as diredcted.
85S&F 35 mm thick factory made, second class hard wood, plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated.
86M/L for Glazed and skeleton shutters of thickness 35mm of IInd class hard wood , open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (a); supplied and fitted to chowkats note: Glazed or clothetc in panelsor sash square shall be measured seperately
87S&Faluminium anodised barrel tower bolt of extruded section 150mm size
88S&F Aluminium anodised barrel tower bolt of extruded section 200 mm size
89S&F Butt hinges 100 mm, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed
90S&F Butt hinges,heavy weight cold rolled mild steel ofsize 125mm.
91S&F extructed aluminium alloy handles, fabricated type,anodised of size 150 mm.
92S & F in repairs aluminium alloy, anodised,300mm sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
93S & F aluminium alloy, anodised,300mm sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
94S&F in repairs galvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised wire staples
95S&F in galvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised wire staples
96S&F in repair MS 300 mm , ordinary rat tail rod pattern springs including rooler and roller plate complete all as specified.
97S&F MS 300 mm , ordinary rat tail rod pattern springs including rooler and roller plate complete all as specified.
98M&L for hacking out old broken glass (any thickness, size, quality or description) from metal frame glazed with putty including punching or drilling out old glazing pin/spring, clips and providing new ones.
99S&F figured sheet glass 3 mm thick, ordinary quality and glazing with oil putty in square n.exc. 0.5 sqm in each paneand complete all as specified.
100Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqmeach and refixing in same opening and complete..Note-Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
101Resecuring or easing & adjusting without taking down shutters of any descriptionexc. 1 sqm butn. exc. 2 sqm each.
102M&L providing and injecting chemical emulsion for post constructional antitermite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per square metre of vertical surface to a depth of 300 mm including channel along the wall and rodding etc. complete all as specified and directed
103M&L for framed work such as grills, grating etc. with ends of bars shouldered and/or riveted, or forged into spikes ; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing framework of water tanks and similar work conforming to Fe290.Gde-E-165 and complete all as specified.
104Demolition of stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. and removing from site all as specified and directed.
105M&L for squared rubble walling, jodhpur type brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:4 and complete all as specified and directed.
106M&L for preparation of old painted wooden surface of any description not otherwise provided over 10 cm width or girth and applying one coats of synthetic enamel paintand complete.
107M&L for preparation of new wooden surface of any description not otherwise provided over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer and complete.
108M&L for preparation of old painted steel surface of any description not otherwise provided over 10 cm width or girth and applying one coats of synthetic enamel paintand complete.
109M&L for preparation of new steel surface of any description not otherwise provided over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide and complete.
110M&L for preperation of plastered and unplastered surface of walls and applying two coats of wheather proof extrerior emulsion paintcomplete all as specified all as directed.
111Supply only integral water proofing compound (ISI marked).
Disclaimer :