West Bengal Power Development Corporation Limited has published Tender For Procurement Of L And T Make Pmcc And Mcc Miscellaneous Components Used For Lt Drives Stage I Water Package At Sgtpp Wbpdcl Under Emoph Department. Submission Date for this Tender is 28-12-2023. Din Rail Tenders in sagardighi West Bengal. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Procurement of L&T Make PMCC & MCC Misclleneous components used for LT drives Stage-I-water package at SgTPP / WBPDCL under EMOPH department |
2 | MCCB,160A # LV 430406X ( COMPLETE SET "L&T Electrical & Automation make 3 Pole MCCB for Motor back-up Protection, Type: DN1-160M, Current Rating: 160 Amps, Breaking Capacity: 50 Ka with L&T Electrical & Automation make Spreader Link for DN1, DN2 - 250 MCCB (ST98053OOOO) , L&T Electrical & Automation make DN1 Extended ROM, (CM98041OOOO), L &T Electrical & Automation make Auxiliary + Trip Alarm Contact (CM97890OOOO) L&T Electrical & Automation make Shunt Release 240 V AC (CM97883OMOO) and Base plate/Adapter Kit" ) |
3 | MOULDED CASE CIRCUIT BREAKER(MCCB) ( COMPLETE SET L&T Electrical & Automation make 3 Pole MCCB for Motor Backup, Type: DN0-100M, Current Rating: 80 Amps, Breaking Capacity: 50 Ka, with L&T Electrical & Automation make Spreader Link for DN0-100M MCCB (CM97785OOOO), L&T Electrical & Automation make DN0 Extended ROM (CM97896OOOO), L&T Electrical & Automation make Auxiliary + Trip Alarm Contact (CM97890OOOO), L&T Electrical & Automation make Shunt Relase 240 V AC(CM97883OMOO) and Base Plate/ Adapter Kit ) |
4 | MCCB POWER CIRCUIT,TP, 50KA,63A ( COMPLETE SET "L&T Electrical & Automation make 3 Pole MCCB for Motor Back-up Protection, Type: DN0-100M, Current Rated: 63 Amps, Breaking Capacity: 50 Ka, with L&T Electrical & Automation make Spreader Link for DN0-100M (CM97785OOOO), L&T Electrical & Automation make Extended ROM (CM97896OOOO), L&T Electrical & Automation make Auxiliary + Trip Alarm Contact (CM97890OOOO), L&T Electrical & Automation make Shunt Release 240V AC (CM97883OMOO) and Base Plate/ Adaptor Kit" ) |
5 | MCCB,100A,DN0-100M FOR LT SYSTEM L&T ( COMPLETE SET L&T Electrical & Automation make 3 Pole MCCB for Motor Back-up Protection, Type: DN0-100M, Current Rated: 100 Amps, Breaking Capacity: 50 Ka, with L&T Electrical & Automation make Spreader Link for DN0-100M (CM97785OOOO), L&T Electrical & Automation make Extended ROM (CM97896OOOO), L&T Electrical & Automation make Auxiliary + Trip Contact (CM97890OOOO), L&T Electrical & Automation make Shunt Release 240 V AC (CM97883OMOO), Base plate/ Adaptor Kit ) |
6 | MCCB,40A,DN0-100M FOR MCCB L&T ( COMPLETE SET L&T Electrical & Automation make 3 Pole MCCB for Motor Back-up Potection, Type: DN01-00M, Current Rating: 40 Amps, Breaking Capacity: 50 Ka, with L&T Electrical & Automation make Spreader Link for DN0-100 (CM97785OOOO), L&T Electrical & Automation make Extended ROM (CM97896OOOO), Auxiliary + Trip Alarm Contact (CM97890OOOO), L&T Electrical & Automation make Shunt Relase 240 V AC (CM97883OMOO) and Base Plate/ Adaptor Kit ) |
7 | MPCB # # FOR TYPE-MNX-G0,O/L RELEASE:10.0A-16.0A ( COMPLETE SET L&T Electrical & Automation make Motor Protection Circuit Breakers, Type: MOG-H1 (Rotary T ype) - Frame 1, Rating: 16 Amps, Thermal Release Range: 11-16 Amps, Instantaneous Trip Current: 208, with L&T Electrical & Automation make Extended ROM (ST41955OOOO), L&T Electrical & Automation make Auxiliary + Trip Alarm Contact (ST41949OOOO), L&T Electrical & Automation make Shunt Release 240 V AC (ST42952OOOO), and Base Plate/ Adaptor Kit ) |
8 | MPCB,4-6.3A,3-POLE,1NO +1NC,DIN RAIL # MPCB,4~6.3A,3-POLE,1NO +1NC,DIN RAIL,ITEM PT.NO.:GV2ME10 ( L&T Electrical & Automation make Motor Protection Circuit Breakers, Type: MOG-H1 (Rotary T ype) - Frame 1, Rating: 6.3 Amps, Thermal Release Range: 4-63 Amps, Instantaneous Trip Current: 81.9, with L&T Electrical & Automation make Extended ROM (ST41955OOOO), L&T Electrical & Automation make Auxiliary + Trip Alarm Contact (ST41949OOOO), L&T Electrical & Automation make Shunt Release 240 V AC (ST42952OOOO) ) |
9 | MPCB 10A,THERMAL RELEASE :6.3 A-- 10.0A ( COMPLETE SET L&T Electrical & Automation make Motor Protection Circuit Breakers, Type: MOG-H1 (Rotary T ype) - Frame 1, Rating: 10 Amps, Thermal Release Range: 6.3-10 Amps, Instantaneous Trip Current: 130, with L&T Electrical & Automation make Extended ROM (ST41955OOOO), L&T Electrical & Automation make Auxiliary + Trip Alarm Contact (ST41949OOOO), L&T Electrical & Automation make Shunt Release 240 V AC (ST42952OOOO), and Base Plate/ Adaptor Kit ) |
10 | CONTACTOR,ML2,400/440V AC # L&T FOR POWER CONTACTORS, 2NO + 2NC,32A ( L&T Electrical & Automation make 3 Pole Power Contactor, Type: ML 2, AC3 Duty, 2NO + 2NC, Size: Fr2, Coil Voltage: 440 V AC(SS90701POOO) ) |
11 | MCCB,125A,TP+N,WITH O/L,S/C PROTECTN ( COMPLETE SET "L&T Electrical & Automation make 3 Pole MCCB for Motor Back-up Protection, Type: DN1-160M, Current Rated: 125 Amps, Breaking Capacity: 50 Ka, with L&T Electrical & Automation make Spreader Link for DN1-160M (ST98053OOOO), L&T Electrical & Automation make Extended ROM (CM98041OOOO), L&T Electrical & Automation make Auxiliary + Trip Alarm Contact (CM97890OOOO), L&T Electrical & Automation make Shunt Release 240 V AC (CM97883OMOO), and Base Plate/ Adaptor Kit" ) |
12 | POWER CONTACTOR MNX-140,COIL 240VAC,50HZ CAT NO.CS94138BOOO LANDT FITTED WITH ADD ON AUX. CONTACTS 2NO+2NC WITH EXTRA 1NO ADD ON AUX. CONTACT BLOCK AT 2ND LEFT(1NO + 1NC) WHICH CAT NO.CS94207 USED ( L&T Electrical & Automation make 3 Pole Power Contactor, Type: MNX 140, AC3 Duty, 2NO + 2NC, Size: Fr4, Coil Voltage: 240 V AC ) |
13 | POWER CONTACTOR,3POLE L&T ( L&T Electrical & Automation make 3 Pole Power Contactor, Type: MNX 80, AC3 Duty, Size: Fr3, Coil Voltage: 240 V AC (CS97077BOOO) ) |
14 | POWER CONTACTOR,240VAC,MNX-18 CS94114 WITH ADD ON AUX CONTACT 1NO ( "L7T Electrical & Automation make 3 Pole Power Contactor, Type: MNX 18, AC3 Duty, 1NO, Size: Fr1, Coil Voltage: 240 V(CS94100BOOO) AC" ) |
15 | ADD-ON AUXILIARY BLOCK FOR MNX FOR CIRCUIT BR ( L&T Electrical & Automation make Add on Auxiliary Contact Block for MNX 9-80, 1NO + 1NC(CS94118OOOO) ) |
16 | ADD ON BLOCK FOR CONTACTORS,3NO+1NC # TYPE-MNX-A1,10A,415V AC,3NO+1NC,CAT.NO.CS94113 ( L&T Electrical & Automation make Add on Auxiliary Contact Block for MNX 9-80, 3NO + 1NC(CS94113OOOO) ) |
17 | AUX CONTACTOR,MXO-22E,240VAC,2NO+2NC COIL VOLTAGE-240VAC ( "L&T Electrical & Automation make Control Relay Auxiliary Contactor, Type: MO0 22E, 2NO + 2NC, Coil Voltage: 240 V(CS91625BOOO) AC" ) |
18 | THERMAL OVERLOAD RELAY,MN12 90-150A L&T , SS94138OOMO ( L&T Electrical & Automation make Thermal Overload Relay, Type: MN 12, Relay Range: 90-150 Amps(SS94138OOMO) ) |
19 | OVERLOAD RELAY,THERMAL,MN5,RANGE:45-75A CAT NO:SS94137OOJO ( L&T Electrical & Automation make Thermal Overload Relay, Type: MN 5, Relay Range: 45-75 Amps(SS94137OOJO) ) |
20 | THERMAL OVERLOAD RELAY,MN5 30-50A L&T ,SS94135OOGO ( L&T Electrical & Automation make Thermal Overload Relay, Type: MN 5, Relay Range: 30-50 Amps(SS94136OOJO) ) |
21 | THERMAL OVERLOAD RELAY,MN5 20-33A L&T ,SS94135OOEO ( L&T Electrical & Automation make Thermal Overload Relay, Type: MN 5, Relay Range: 20-33 Amps(SS94136OOEO) ) |
22 | THERMAL OVERLOAD RELAY ( L&T Electrical & Automation make Thermal Overload Relay, Type: MN 12, Relay Range: 28-46.5 Amps(SS94211OOGO) ) |
23 | THERMAL OVERLOAD RELAY,MN5 9-15A L&T ,SS94135OOBO ( L&T Electrical & Automation make Thermal Overload Relay, Type: MN 2, Relay Range: 9-15 Amps(SB94142OOBO) ) |
24 | THERMAL OVERLOAD RELAY,MN2 4.5-7.5A L&T ,SS94141OOUO L&T ( L&T Electrical & Automation make Thermal Overload Relay, Type: MN 2, Relay Range: 4.5-7.5 Amps(SS94141OOUO) ) |
25 | OLR, MN-2,RANGE-2A-3.3A SS94141OOQO L&T ( L&T Electrical & Automation make Thermal Overload Relay, Type: MN 2, Relay Range: 2-3.3 Amps(SS94141OOQO) ) |
26 | O/L RELAY: MN 2, 1.4 - 2.3A FOR COOLING TO ( L&T Electrical & Automation make Thermal Overload Relay, Type: MN 2, Relay Range: 1.4-2.3 Amps(SS94141OOPO) ) |
27 | SELECTOR SWITCH,1 POLE,2 WAY(ON & OFF) # L&T AC 21A 440V-6A/AC 15 440V 1A MAKE L&T(saizer) ( L&T Electrical & Automation make Chnageover Slector Switch, 6 Amps, 1 Pole 2 Way with Off(61025SAB13TDYR) ) |
28 | CONTACTOR MX0 22E,(2NO+2NC) ( "L&T Electrical & Automation make Control Relay Auxiliary Contactor, Type: MX0 22E, 2NO + 2NC, Coil Voltage: 24 V DC"(CS94029OOO) ) |
29 | TRIP/NEUTRAL/CLOSE SWITCH # ( L&T Electrical & Automation make Breaker Control Switches (Trip - Neutral - Close), Rating: 25 Amps, Contact Arrangement: 2Trip + 2Close, Mounting Type: Standard(72009SEB03PGBB) ) |
30 | HRC FUSE:2A # ( L&T Electrical & Automation make Cylindrical HRC Fuse Link, Rated Current: 2 Amps, Szie: 14 x 51, Breaking(SF90144OOOO) ) |
31 | RELAY RESET CORD-400MM,WITH SWITCH # L&T FOR MN TYPE OVERLOAD RELAY,CAT NO: SB94207# FOR MN TYPE OVERLOAD RELAY,CAT NO:SB94207 ( L&T Electrical & Automation make MN Relay Reset Cord - 400MM (SB94208OOOO) ) |
32 | RELAY RESET CHORD, WITH SWITCH ( L&T Electrical & Automation make MN Relay Reset Cord - 650MM (SB94208OOOO) ) |
33 | RELAY RESET CORD-900MM,WITH SWITCH # L&T FOR MN TYPE OVERLOAD RELAY, CAT NO: SB94209# FOR MN TYPE OVERLOAD RELAY,CAT NO:SB94209 ( L&T Electrical & Automation make MN Relay Reset Cord - 900MM (SB94209OOOO) ) |
34 | RELAY RESET CORD-1200MM,WITH SWITCH # L&T FOR MN TYPE OVERLOAD RELAY, CAT NO: SB94210# FOR MN TYPE OVERLOAD RELAY,CAT NO:SB94210 ( L&T Electrical & Automation make MN Relay Reset Cord - 1200MM (SB94210OOOO) ) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy