Tender For Improvement Of Eiectrical Installations Ct(S) Located At Tulsi Ram Dharamshala , Sports Complex Kirti Nagar, 9 Block Moti Nagar, Near Kailash Nursing Home South Patel Nagar, Various Ct(S) And Pt(S) Underkarol Bagh Zone-Improvement Of Eiectrical, karol-Delhi

Municipal Corporation Of Delhi has published Tender For Improvement Of Eiectrical Installations Ct(S) Located At Tulsi Ram Dharamshala , Sports Complex Kirti Nagar, 9 Block Moti Nagar, Near Kailash Nursing Home South Patel Nagar, Various Ct(S) And Pt(S) Underkarol Bagh Zone-Improvement Of Eiectrical. Submission Date for this Tender is 18-12-2023. Bolts Tenders in karol Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

41047065
Tender For Improvement Of Eiectrical Installations Ct(S) Located At Tulsi Ram Dharamshala , Sports Complex Kirti Nagar, 9 Block Moti Nagar, Near Kailash Nursing Home South Patel Nagar, Various Ct(S) And Pt(S) Underkarol Bagh Zone-Improvement Of Eiectrical
Open Tender
Indian
Delhi
karol
18-12-2023

Tender Details

Improvement Of Eiectrical Installations Ct ( S ) Located At Tulsi Ram Dharamshala , Sports Complex Kirti Nagar, 9 Block Moti Nagar, Near Kailash Nursing Home South Patel Nagar, Various Ct ( S ) And Pt ( S ) Underkarol Bagh Zone-Improvement Of Eiectrical Installations Ct ( S ) Located At Tulsi Ram Dharamshala , Sports Complex Kirti Nagar, 9 Block Moti Nagar, Near Kailash Nursing Home South Patel Nagar, Various Ct ( S ) And Pt ( S ) Underkarol Bagh Zone; 2 Od18280 / 2023-2024:Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required Group B 3 Od18281 / 2023-2024: Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required Group B 4 Od18283 / 2023-2024: Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3X4 Sqmm 5 Od18284 / 2023-2024: Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. ( A ) 3X 2.5 Sqmm 6 Od18282 / 2023-2024:Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Cm 7 Od18293 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. ( A ) 5 / 6 Amp Switch 8 Od18292 / 2023-2024:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. ( B ) 3 Pin 5 / 6 Amp Socket Outlet 9 Od18294 / 2023-2024:Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 10 Od18295 / 2023-2024:Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 A 11 Od18297 / 2023-2024:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. ( A ) 8 Module ( 125 Mmx125 Mm ) 12 Od18296 / 2023-2024:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. ( B ) 12 Module ( 200 Mmx150 Mm ) 13 Od18298 / 2023-2024:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 8 Way Double Door 14 Od18299 / 2023-2024:Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required.Upto 450Mm Sweep 15 Od18301 / 2023-2024:Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. ( But Without Charcoal / Coke And Salt ) As Required. 16 Od18300 / 2023-2024:Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Reqd. 17 Od18302 / 2023-2024:Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm 18 Od18303 / 2023-2024:Laying Of One No Pvc Insulated And Pvc Sheathed / Xple Al Conductor Armoured Power Cable Of 1.1Kv Grade Of Following Sizeon Wall Surface As Required. Up To 35 Sq, Mm ( Clamped With 1Mm Thick Saddle ) 19 Od18340 / 2023-2024:Sitc Of Single Phase Monoblock Pump Set Complete With All Accessories Workable On 240 / 415 Volt 50 Hz Ac Supply ( A ) 1 Hp ( 0.75Kw ) Single Phase Pump Set Head From 12-30 Metre Suction And Delivery 25X25 Mm 20 Approved Rates 21 122.1.2:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C*6 Sqmm 22 122.2.31:Sitc Of 18 / 20W Led Street Light Luminaire Fitted With Lens, Top Opening Driver Cover Made Of Pressure Die Cast Aluminium Housing & Toughened Glass Cover Complete With The Following Specification As Reqd With Ip 66 Protection ( A ) Total System Wattage =18 / 20 Watt + / - 5% ( B ) Luminaire Efficacy>=100 Lm / W ( C ) Power Factor>=0.95 ( D ) Protection Class- Ip-66 23 122.2.39:S / I / T / C Of Led Tube Type Luminaire 20 Watt Rating Complete With Polycarbonate Housing Batten Integrated Electronic Driver Prewired With High Efficient Leds With The Following: ( A ) Total System Wattage 20 Watt + / - 5% ( B ) Luminous Efficacy Lumens / Watt >=95 ( C ) Power Factor >=0.95 24 Od18337 / 2023-2024:Supply Of 15&Amp;Quot; ( 375Mm ) Sweep 1400 Rpm Exhaust Fan Heavy Duty Complete With Shutters Blades Etc As Reqd 25 122.2.190:Supply And Fixing Of 32Mm Dia X 1 Meter Long G.I. Pipe ( Medium Class ) Bracket For Mounting Of Fluorescent / Hpmv / Hpsv Street Light Fitting On Pole Including Bending The Pipe To The Required Shape , 2 Nos 25Mm X 6Mm Flat Iron Clamps With Nuts, Bolts And Washer , Painting The Flat Iron With Primer And Finish Paint Etc. As Reqd.

Key Value

Document Fees
INR 590 /-
EMD
INR 10000.0 /-
Tender Value
INR 4.98 Lakhs /-

BOQ Items

Work Name:Improvement of EIectrical Installations CT(s) located at Tulsi Ram dharamshala , Sports Complex Kirti Nagar, 9 Block Moti Nagar, near Kailash nursing home South Patel Nagar, various CT(s) and PT(s) underKarol Bagh Zone-Improvement of EIectrical Installations CT(s) located at Tulsi Ram dharamshala , Sports Complex Kirti Nagar, 9 Block Moti Nagar, near Kailash nursing home South Patel Nagar, various CT(s) and PT(s) underKarol Bagh Zone
Sl. No. Item Description
1SR ITEMS
2OD18280/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group B
3OD18281/2023-2024: Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required Group B
4OD18283/2023-2024: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x4 sqmm
5OD18284/2023-2024: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a)3x 2.5 sqmm
6OD18282/2023-2024:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 cm
7OD18293/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a) 5/6 amp switch
8OD18292/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(b) 3 pin 5/6 amp Socket Outlet
9OD18294/2023-2024:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
10OD18295/2023-2024:Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
11OD18297/2023-2024:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (a) 8 Module (125 mmX125 mm)
12OD18296/2023-2024:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (b)12 Module (200 mmX150 mm)
13OD18298/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way Double Door
14OD18299/2023-2024:Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450mm Sweep
15OD18301/2023-2024:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
16OD18300/2023-2024:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as reqd.
17OD18302/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
18OD18303/2023-2024:Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of following sizeon wall surface as required. Up to 35 sq,mm (clamped with 1mm thick saddle)
19OD18340/2023-2024:SITC of single phase monoblock pump set complete with all accessories workable on 240 / 415 Volt 50 Hz AC Supply (a) 1 hp (0.75kW) single phase pump set head from 12-30 metre suction and delivery 25x25 mm
20APPROVED RATES
21122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
22122.2.31:SITC of 18/20W LED Street Light luminaire fitted with lens, top opening driver cover made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =18/20 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
23122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
24OD18337/2023-2024:Supply of 15" (375mm) sweep 1400 rpm exhaust fan heavy duty complete with shutters blades etc as reqd
25122.2.190:Supply and fixing of 32mm dia X 1 meter long G.I. Pipe (Medium Class) bracket for mounting of fluorescent/HPMV/HPSV Street Light fitting on pole including bending the pipe to the required shape , 2 nos 25mm X 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd.