Tender For Repair And Maintenance Of B & C Types Of Quarters In Khetri Nagar Township; 1 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Meters And Under Including Cutting The Patch In Proper Shape, Raking Outjointsandpreparingandplasteringthesurfaceofthewalls Completeincluding Disposalofrubbishtothedumpinggroundwithin 50Metres Lead :With Cement Mortar 1:4 ( 1 Cement : 4 Fine Sand ) 2 6 Mm Cement Plaster Of Mix :1:3 ( 1 Cement: 3 Fine Sand ) 3 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 4 Dismantlingoldplasterorskirtingrakingoutjointsandcleaningthe Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead. 5 Half Brick Masonry With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) 6 Carriage Of Material By Mechanical Transport Including Loading, Unloading And Stacking: Lime, Moorum, Building Rubbish: Lead 1 Km. 7 Cement Concrete Flooring1:2:4 ( 1 Cement : 2 Coarse Sand :4Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete.40Mm Thick With 20Mm Nominal Size Stone Aggregate. 8 Demolishingcementconcretemanually / Bymechanicalmeans Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge.1:3:6 Or Richer Mix 9 Providing & Fixing Stone Door Frame Of Required Size Including Dowels, Grouted In Cement Mortar 1:3 With Necessary Holes For Fixing Hinges, Door Bolt Etc Complete As Per Direction Of Engineer-In-Charge. 10 Providing And Fixing Panelled Or Panelled And Glazed Shutter For Doors, Windows And Clerestory Windows Including Black Enamelled M.S. But Hinges With Necessary Screws. Second Class Kail Wood ( 35 Mm Thick ) . 11 2. Providing And Fixing Glazed Shutters For Doors, Windows, Clerestory Windows Using 7.5Kg / Sq, M 3Mm Thick Glass Panes Including Black Enamelled Ms Butt Hinges With Necessary Screws: 35Mmthick Second Class Kail Wood. 12 Providing And Fixing Panalleled Or Panelled Or Glazed Shutter For Doors, Windown And Cleres Tory Windows Including Black Enamelled M.S. But Hinges With Necessary Screws. Second Class Kail Wood ( 25 Mm Thick ) . 13 Takingoutdoors, Windowsandclerestorywindowshutters ( Steelor Wood ) Including Stacking Within 50 Meters Lead: Of Area 3 Sq. Meters And Below 14 Providingandfixingoxidisedm.S.Haspandstaple ( Safetytype ) Conforming To Is : 363 With Necessary Screws Etc. Complete : 150 Mm 15 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is: 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters : 30 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws. 16 Applying Priming Coat :With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work ( Hard And Soft Wood ) 17 Paintingwithsyntheticenamelpaintofapprovedbrandand Manufacture To Give An Even Shade :Two Or More Coats On New Work 18 Removing & Refixing Of Old Tower Bolts ( Labour Rates Only ) 19 Removing & Refixing Of Old Handles ( Labour Rates Only ) 20 Removing &Reficing Of Old Sliding Door Bolts ( Labour Rate Only ) 21 Renewing Glass Panes With Wooden Fillets Wherever Necessary Glass Weighing 10 Kg / Sqm ( 4Mm Thickness ) 22 Providing And Fixing Factory-Made P.V.C Door Frame Of Size 50X47 Mm With A Wall Thickness Of 5 Mm, Made Out Of Extruded 5 Mm Rigid P.V.C Foam Sheet Mitered At Corners And Joined With 2 Numbers Of 150 Mm Long Brackets Of 15X15 M.S Square Tube, The Vertical Door Profiles To Be Reinforced With 19X19 Mm Square Tube Of 19-Gauge, Epdm Rubber Gasket Weather Seal To Be Provided Throughout The Frame. The Door Frame To Be Fixed To The Wall Using M.S Screws Of 65 / 100 Mm Size Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge. 23 Providing And Fixing To Existing Door Frame: - 30 Mm Thick Factory-Made P.V.C Door Shutter Consisting Of Frame Made Out Of M. S Tubes 0F 19-Gauge Thickness And 15M.Mx15m.M For Top & Bottom Rails. M.S Frame Shall Have A Coat Of Steel Primer Of Approved Make And Manufactures. M.S Frame Covered With 5 Mm Thick Heat Moulded P.V.C C Channel Of Size 30 Mm Thickness , 70M.M Width Out Of Which 50 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree Angle On Either Side Forming Style; And 5M.M Thick, 95 Mm Wide P.V.C Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide P.V.C Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Side To Form Lock Rail. Top, Bottom And Lock Rail Shall Be Provided Either Side Of The Panel. 10 Mm ( 5Mmx2 ) Thick, 20 Mm Wide Cross P.V.C Sheet Be Provided As Gap Insert For Top Rail And Bottom Rail. Paneling Of 5 Mm Thick Both Side P.V.C Sheet To Be Fitted In The M.S Frame Wielded / Sealed To The Style & Rails With 7 Mm ( 5M.M+ 2 Mm ) Thick X 15 Mm Wide P.V.C Sheet Beading On Inner Side And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick P.V.C Strip Of 20 Mm Width Is To Be Stuck On The Interior Side Of The C Channel Using P.V.C Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge. Manufacturer’S Specification And Drawing ( For W.C And Bathroom Door Shutter ) 24 Providing & Fixing Of M.S. Bathroom Locking Bolt Of Size 65 M.Mx 50 M.M. ( Weighingnot Less Than 120 Gramme Each ) With Necessary Screws. 25 Providing & Fixing Ofoxidised M.S. Tower Boltbarrel Type Of Size 100M.M. X 10 M.M. 26 Providing & Fixing Ofoxidised M.S.Handle Of Size 100 M.M. 27 Providing & Fixing Ofs.S.Heavy Weight But Hinges ( Size 100X75x3 M.M. ) With Necessary Screws 28 P / F Holdfasts Of Flat Size 35Mmx3mm & 150 Mm Length For Pvc Door Frames Including Cutting Holes In Rrm / Brick Walls Of Size 150X100x100 Mmand Filling C.C. 1:2:4 In The Holecomplete. 29 Dismantling Doors Windows And Clerstory Windows ( Steel Or Wood ) Shrtter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Depositing The Same In Central / Site Stores. Of Area 3 Sq.M And Below 30 Providingandfixingonwall Faceunplasticised Rigidpvcrainwater Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conformingtois: 5382 Leaving 10 Mm Gap For Thermal Expansion ( I ) Single Socketed Pipes. 75 Mm Diameter 31 Providingandfixingonwall Faceunplasticised Rigidpvcrainwater Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conformingtois: 5382 Leaving 10 Mm Gap For Thermal Expansion. ( I ) Single Socketed Pipes. 110 Mm Diameter 32 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion. Shoe ( Plain ) - 110 Mm 33 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete 75 Mm 34 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 110 Mm 35 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 With 10Mm Gap For Thermal Expansion. Coupler - 75 Mm 36 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10 Mm Gap For Thermal Expansion Coupler - 110 Mm 37 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382 Leaving 10Mm Gap For Thermal Expansion. Bend 87.5°- 75 Mm Bend 38 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is :5382Leaving 10 Mm Gap For Thermal Expansion Bend 87.5°- 110 Mm Bend 39 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) 40 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:3:6 ( 1Cement:3Coarsesand:6Gradedstone Aggregate 20 Mm Nominal Size ) . 41 Providing And Laying 20 Mm Thick Precast Cement Concrete Tiles Over Roofs ( As Per I.S.1237-1980 ) With 1:2:4 Mix ( 1 Cement: 2Coarse Sand:4 Coarse Stone Aggregate 6 Mm Down Grade ) Finished With Neat Cement Punning, Laid Over Bed Of Cement Lime Plaster 1:1:6 ( 1 Cement :1 Lime Putty :6 Fine Sand ) , 15Mm Average Thickness In Required Slope After Cleaning And Removal Of Existing Terfelt Including Disposal Of Dismentled Terfelt, Including Racking Of Joints And Flush Pointing With Cement Morter 1:3 ( Cement :3 Fine Sand ) On Roofs Including Providings Gola Wherever Required As Per Specification. 42 Grading Roof For Water Proofing Treatment With Cementconcrete1:2:4 ( 1Cement:2Coarsesand:4 Graded Stone Aggregate 20 Mm Nominal Size ) 43 Providing And Fixing By Nailoing 30 C.M. Wide Chicken / Rabbit Mesh On The Walls Surface As Per Direction Of Engineer In-Charge. 44 Providing And Laying In Position Bitumen Sand For Expansion Joint Etc Using 128 Kg Bitumen Grade 80 / 100 Per Cu.M Of Sand Etc. Complete As Per Difection Of Engineer In Charge. 45 Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls ( Anythickness ) Includingattachedpilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bedblocks, Anchorblocks, Plainwindowsills, Filletsetc.Uptofloorfivelevel, Excludingthecostofcentering, Shuttering And Finishing :1:2:4 ( 1Cement:2Coarsesand:4Gradedstone Aggregate 20 Mm Nominal Size ) 46 Makingkhurras45x45cmwithaverage Minimumthicknessof5cm Cementconcrete1:2:4 ( 1Cement:2Coarsesand:4Gradedstone Aggregate Of 20Mm Nominal Size ) Over P.V.C. Sheet 1Mx1mx400micron, Finished With 12Mm Cement Plaster 1:3 ( 1 Cement : 3Coarsesand ) Andacoatofneatcementroundingtheedgesand Making And Finishing The Outlet Complete. 47 20 Mm Cement Plaster Of Mix :1:6 ( 1 Cement: 6 Fine Sand ) 48 Extra Item. Providing Gola 75X75 Mm In C.C 1:2:4 Including Finishing With C.M 1:3 As Per Standard Design In 75X75 Deepchase. 49 Reconstruction Of Chajjas After Completely Dismantling Of Existing Damaged Chajja Of Thickness 75-100 Mm And Length Upto 1.0 Meters With Rcc Grade-M20 ( 1:1.5:3 ) ( Only Reinforcement Will Be Paid Separately ) . 50 Reconstruction Of Chajjas After Completely Dismantling Of Existing Damaged Chajja Of Thickness 75-100 Mm And Length More Than 1.0 Meters And Upto 2.0 Meters With Rcc Grade-M20 ( 1:1.5:3 ( Only Reinforcement Will Be Paid Separately ) . 51 Reconstruction Of Chajjas After Completely Dismantling Of Existing Damaged Chajja Of Thickness 75-100 Mm And Length More Than 2.0 Meters And Upto 3.0 Meters With Rcc Grade-M20 ( 1:1.5:3 ( Only Reinforcement Will Be Paid Separately ) . 52 Reinforcementforr.C.C. Workincludingstraightening, Cutting, Bending, Placing In Position And Binding All Complete. Cold Twisted Bars

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Dec-2023 Change in UoM Technical Bid 01-01-2024

Key Value

Document Fees
Refer document
EMD
INR 132000.0 /-
Tender Value
INR 66.01 Lakhs /-

BOQ Items

Name of Work: Repair and maintenance of B & C types of quarters in Khetri Nagar Township
Sl. No. Item Description
1Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking outjointsandpreparingandplasteringthesurfaceofthewalls completeincluding disposalofrubbishtothedumpinggroundwithin 50metres lead :With cement mortar 1:4 (1 cement : 4 fine sand)
26 mm cement plaster of mix :1:3 (1 cement: 3 fine sand)
315 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand)
4Dismantlingoldplasterorskirtingrakingoutjointsandcleaningthe surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead.
5Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
6Carriage of material by mechanical transport including loading, unloading and stacking: Lime, moorum, building rubbish: Lead 1 KM.
7Cement concrete flooring1:2:4 (1 cement : 2 coarse sand :4graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick with 20mm nominal size stone aggregate.
8Demolishingcementconcretemanually/bymechanicalmeans including disposal of material within 50 metres lead as per direction of Engineer - in - charge.1:3:6 or richer mix
9PROVIDING & FIXING STONE DOOR FRAME OF REQUIRED SIZE INCLUDING DOWELS,GROUTED IN CEMENT MORTAR 1:3 WITH NECESSARY HOLES FOR FIXING HINGES,DOOR BOLT ETC COMPLETE AS PER DIRECTION OF ENGINEER-IN-CHARGE.
10PROVIDING AND FIXING PANELLED OR PANELLED AND GLAZED SHUTTER FOR DOORS, WINDOWS AND CLERESTORY WINDOWS INCLUDING BLACK ENAMELLED M.S. BUT HINGES WITH NECESSARY SCREWS. SECOND CLASS KAIL WOOD(35 MM THICK).
112. PROVIDING AND FIXING GLAZED SHUTTERS FOR DOORS, WINDOWS, CLERESTORY WINDOWS USING 7.5KG/SQ,M 3MM THICK GLASS PANES INCLUDING BLACK ENAMELLED MS BUTT HINGES WITH NECESSARY SCREWS: 35MMTHICK SECOND CLASS KAIL WOOD.
12PROVIDING AND FIXING PANALLELED OR PANELLED OR GLAZED SHUTTER FOR DOORS, WINDOWN AND CLERES TORY WINDOWS INCLUDING BLACK ENAMELLED M.S. BUT HINGES WITH NECESSARY SCREWS. SECOND CLASS KAIL WOOD (25 MM THICK).
13Takingoutdoors,windowsandclerestorywindowshutters(steelor wood) including stacking within 50 meters lead: Of area 3 sq. meters and below
14ProvidingandfixingoxidisedM.S.haspandstaple(safetytype) conforming to IS : 363 with necessary screws etc. complete : 150 mm
15Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
16Applying priming coat :With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
17Paintingwithsyntheticenamelpaintofapprovedbrandand manufacture to give an even shade :Two or more coats on new work
18REMOVING & REFIXING OF OLD TOWER BOLTS (LABOUR RATES ONLY)
19REMOVING & REFIXING OF OLD HANDLES (LABOUR RATES ONLY)
20REMOVING &REFICING OF OLD SLIDING DOOR BOLTS (LABOUR RATE ONLY)
21Renewing glass panes with wooden fillets wherever necessary glass weighing 10 kg/sqm (4mm thickness)
22Providing and fixing factory-made P.V.C door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid P.V.C foam sheet mitered at corners and joined with 2 numbers of 150 mm long brackets of 15x15 M.S square tube, the vertical door profiles to be reinforced with 19x19 mm square tube of 19-gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S screws of 65/100 mm size complete as per manufacturers specification and direction of Engineer-In-Charge.
23Providing and fixing to existing door frame: - 30 mm thick factory-made P.V.C door shutter consisting of frame made out of M. S Tubes 0f 19-gauge thickness and 15m.mx15m.m for top & bottom rails. M.S frame shall have a coat of Steel primer of approved make and manufactures. M.S frame covered with 5 mm thick heat moulded P.V.C "C " channel of size 30 mm thickness ,70m.m width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either side forming style; and 5m.m thick,95 mm wide P.V.C sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide P.V.C Sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both side to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. 10 mm (5mmx2) thick, 20 mm wide cross P.V.C Sheet be provided as gap insert for top rail and bottom rail. Paneling of 5 mm thick both side P.V.C Sheet to be fitted in the M.S frame wielded/ sealed to the style & rails with 7 mm (5m.m+ 2 mm) thick x 15 mm wide P.V.C Sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm thick P.V.C strip of 20 mm width is to be stuck on the interior side of the "C" channel using P.V.C solvent adhesive etc. complete as per direction of Engineer-In-Charge. Manufacturer’s specification and drawing (for W.C and Bathroom Door shutter)
24PROVIDING & FIXING OF M.S. BATHROOM LOCKING BOLT OF SIZE 65 M.MX 50 M.M.(WEIGHINGNOT LESS THAN 120 GRAMME EACH ) WITH NECESSARY SCREWS.
25PROVIDING & FIXING OFOXIDISED M.S. TOWER BOLTBARREL TYPE OF SIZE 100M.M. X 10 M.M.
26PROVIDING & FIXING OFOXIDISED M.S.HANDLE OF SIZE 100 M.M.
27PROVIDING & FIXING OFS.S.HEAVY WEIGHT BUT HINGES( SIZE 100X75X3 M.M. ) WITH NECESSARY SCREWS
28P/F Holdfasts of flat size 35mmx3mm & 150 mm Length for PVC Door frames including cutting holes in RRM/Brick walls of size 150x100x100 MMand filling C.C. 1:2:4 in the holecomplete.
29DISMANTLING DOORS WINDOWS AND CLERSTORY WINDOWS (STEEL OR WOOD) SHRTTER INCLUDING CHOWKHATS, ARCHITRAVE, HOLDFASTS ETC. COMPLETE AND DEPOSITING THE SAME IN CENTRAL/SITE STORES. OF AREA 3 SQ.M AND BELOW
30Providingandfixingonwall faceunplasticised RigidPVCrainwater pipes conforming to IS : 13592 Type A including jointing with seal ring conformingtoIS: 5382 leaving 10 mm gap for thermal expansion (i) Single socketed pipes. 75 mm diameter
31Providingandfixingonwall faceunplasticised RigidPVCrainwater pipes conforming to IS : 13592 Type A including jointing with seal ring conformingtoIS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. 110 mm diameter
32Providing and fixing on wall face unplasticised - PVC moulded fittings/Accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Shoe (Plain)- 110 mm
33Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete 75 MM
34Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 MM
35Providing and fixing on wall face unplasticised - PVC moulded fittings/Accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 with 10mm gap for thermal expansion. Coupler - 75 mm
36PROVIDING AND FIXING ON WALL FACE UNPLASTICISED - PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAIN WATER PIPES CONFORMING TO IS : 13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS :5382 leaving 10 mm gap for thermal expansion Coupler - 110 mm
37Providing and fixing on wall face unplasticised - PVC moulded fittings/Accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10mm gap for thermal expansion. Bend 87.5°- 75 mm bend
38PROVIDING AND FIXING ON WALL FACE UNPLASTICISED - PVC MOULDED FITTINGS/ ACCESSORIES FOR UNPLASTICISED RIGID PVC RAIN WATER PIPES CONFORMING TO IS : 13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS :5382leaving 10 mm gap for thermal expansion Bend 87.5°- 110 mm bend
39Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
40Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6(1Cement:3coarsesand:6gradedstone aggregate 20 mm nominal size).
41PROVIDING AND LAYING 20 MM THICK PRECAST CEMENT CONCRETE TILES OVER ROOFS (AS PER I.S.1237-1980) WITH 1:2:4 MIX (1 CEMENT: 2COARSE SAND:4 COARSE STONE AGGREGATE 6 MM DOWN GRADE) FINISHED WITH NEAT CEMENT PUNNING, LAID OVER BED OF CEMENT LIME PLASTER 1:1:6 (1 CEMENT :1 LIME PUTTY :6 FINE SAND), 15MM AVERAGE THICKNESS IN REQUIRED SLOPE AFTER CLEANING AND REMOVAL OF EXISTING TERFELT INCLUDING DISPOSAL OF DISMENTLED TERFELT, INCLUDING RACKING OF JOINTS AND FLUSH POINTING WITH CEMENT MORTER 1:3 (CEMENT :3 FINE SAND) ON ROOFS INCLUDING PROVIDINGS GOLA WHEREVER REQUIRED AS PER SPECIFICATION.
42Grading roof for water proofing treatment with Cementconcrete1:2:4(1cement:2coarsesand:4 graded stone aggregate 20 mm nominal size)
43PROVIDING AND FIXING BY NAILOING 30 C.M. WIDE CHICKEN/RABBIT MESH ON THE WALLS SURFACE AS PER DIRECTION OF ENGINEER IN-CHARGE.
44PROVIDING AND LAYING IN POSITION BITUMEN SAND FOR EXPANSION JOINT ETC USING 128 KG BITUMEN GRADE 80/100 PER CU.M OF SAND ETC. COMPLETE AS PER DIFECTION OF ENGINEER IN CHARGE.
45Providing and laying cement concrete in retaining walls, return walls, walls(anythickness)includingattachedpilasters,columns,piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets,coping,bedblocks,anchorblocks,plainwindowsills, filletsetc.uptofloorfivelevel,excludingthecostofcentering, shuttering and finishing :1:2:4(1Cement:2coarsesand:4gradedstone aggregate 20 mm nominal size)
46Makingkhurras45x45cmwithaverage minimumthicknessof5cm cementconcrete1:2:4(1cement:2coarsesand:4gradedstone aggregate of 20mm nominal size) OVER P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3coarsesand)andacoatofneatcementroundingtheedgesand making and finishing the outlet complete.
4720 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
48EXTRA ITEM. PROVIDING GOLA 75X75 MM IN C.C 1:2:4 INCLUDING FINISHING WITH C.M 1:3 AS PER STANDARD DESIGN IN 75X75 DEEPCHASE.
49Reconstruction of CHAJJAS after completely dismantling of existing damaged chajja of thickness 75-100 mm and Length upto 1.0 Meters with RCC GRADE-M20 (1:1.5:3 )( only Reinforcement will be paid separately).
50Reconstruction of CHAJJAS after completely dismantling of existing damaged chajja of thickness 75-100 mm and Length more than 1.0 Meters and upto 2.0 Meters with RCC GRADE-M20 (1:1.5:3 ( only Reinforcement will be paid separately).
51Reconstruction of CHAJJAS after completely dismantling of existing damaged chajja of thickness 75-100 mm and Length more than 2.0 Meters and upto 3.0 Meters with RCC GRADE-M20 (1:1.5:3 ( only Reinforcement will be paid separately).
52ReinforcementforR.C.C. workincludingstraightening,cutting, bending, placing in position and binding all complete. Cold twisted bars