Tender For Construction Of Disaster Management Shed For Public Utility In Museum Premises At Glr Sy. No. 118(Part), shahjahanpur-Uttar Pradesh

Cantonment Board-CB has published Tender For Construction Of Disaster Management Shed For Public Utility In Museum Premises At Glr Sy. No. 118(Part). Submission Date for this Tender is 01-01-2024. Shed Construction Tenders in shahjahanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41045561
Tender For Construction Of Disaster Management Shed For Public Utility In Museum Premises At Glr Sy. No. 118(Part)
Open Tender
Indian
Uttar Pradesh
shahjahanpur
01-01-2024

Tender Details

Tender For Construction Of Disaster Management Shed For Public Utility In Museum Premises At Glr Sy. No. 118 ( Part ) ; 1 Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out 2 M&L Cement Concrete In Foundations Type D-2 1:4:8 ( 40 Mm Graded Aggregate ) Filling And Mass Concrtete. 3 M&L For Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits ( If Any ) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter Finished Surface Fair And Even Complete Allspecified And Directed. 4 M&L For Formwork To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Finished Surface Fair And Even Complete Allspecified And Directed. 5 M&L For Formwork To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work; Not Exceeding 200Mm Thick ( Horizontal Or Sloping ) Finished Surface Fair And Even Complete All Specified And Directed. 6 M&L For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. Finished Surface Fair And Even Complete Allspecified And Directed. 7 M&L For Rcc Work With Cement Approved Corse Sand And 20Mm Graded Aggregates Approved Stone Ballast Confirming M-20 Mixed In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Excluding Steel Reinforcement And Formwork Complete All Specified And Directed. 8 M&L For Rcc Work With Cement Approved Corse Sand And 20Mm Graded Aggregates Approved Stone Ballas Confirming M-20 Mixed Incolumns, Pillars, Piers, Posts And Struts Excluding Steel Reinforcement And Formwork Complete All Specified And Directed. 9 M&L For Earth Filling Back Side Wall Alongwith Flooring Portion, Including, Spreading And Levelling, Including, Watering, Well Ramming Etc In Layers And Exc 25Cm Thick And Rough Excavated Material Lead Exc 1.5 Km But N Exc 5 Km Depositing Where Directed. 10 M&L Treating The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface Area 11 M&L For Treating The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface ( Area Of The Sub Structure In Contact With Backfill To Be Measured ) Complete All Specified And Directed. 12 M&L For Treating The Soil Along With External Perimeter Of Building At The Rate Of 2.25 Litre Of Emulsion Per Metre Of The Perimeter Wall Complete All Specified And Directed. 13 M&L For Rcc Work With Cement Approved Corse Sand And 20Mm Graded Aggregates Approved Stone Ballas Confirming M-20 Mixed In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves Excluding Steel Reinforcement And Formwork Complete All Specified And Directed. 14 M&L For Rcc Work With Cement Approved Corse Sand And 20Mm Graded Aggregates Approved Stone Ballas Confirming M-20 Mixed Inbeams, Cantilevers, Bressummers, Lintels Over 1.5M Span Excluding Steel Reinforcement And Formwork Complete All Specified And Directed. 15 M&L For Brickwork With Subclass ‘B’ Bricks, Straight Or Curved On Plan Exc 6M Mean Substructure Radius Built In Cement Motar 1:6 Complete All Specified And Directed. 16 M&L For Brickwork With Subclass ‘B’ Bricks, Straight Or Curved On Plan Exc 6M Mean Superstructure Radius Built In Cement Motar 1:6 Complete All Specified And Directed. 17 M&L For Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips As In Reinforcement Complete Allspecified And Directed 18 M&L For Tmt Bars 6Mm To 8Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clipsas In Reinforcement Complete Allspecified And Directed. 19 M&L Brickwork With Subclass ‘B’ Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Thick Walls Built In ( 1:4 Cement Mortar ) 20 M&L For 12Mm Thick Cement Plastring In 1:6 Cement Motar On Fair Faces Of Brick Work Or Concrete Surface Finished Even And Smooth Without Using Extra Cement On Internal Surface Complete Allspecified And Directed. 21 M&L For 12Mm Thick Cement Plastring In 1:6 Cement Motar On Fair Faces Of Brick Work Or Concrete Surface Finished Even And Smooth Without Using Extra Cement On Outer Surface Complete Allspecified And Directed-Other Than Fair Surface 22 3Mm Thick Wall Care Putty On Wall 23 3Mm Thick Wall Care Putty On Ceiling 24 M&L Fordistemper Paint- I.E. Applying Two Coat Of Interioremulsion Paint ( Appeex ) And Preparation Of Newly Plastered Surface Interiorside, Ceiling Complete All Specified And Directed 25 M&L For Two Coat Plastic Emulsion Paint And Preparation Of Newly Plastered Surface Of Wall For External Side Complete All Specified And Directed By E / I. 26 Supply & Fixing 30Mm Thick Flush Shutter Solid Core Construction With Particle Board Core & Plywood Face With Decorative Face Veneer With Lipping Frame To Match 27 M&L For Preparation Of New Steel And Iron Surface Of Any Description Over 10Cm Width As Girth And Applying Two Coat Of Synthetic Enamel Paint Over Coat Of Red Oxide Primer Complete All As Specified And Directed 28 M&L For 125× 60Mm Pressed Steel Frames For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete, As Specified, Supplied And Fixed Complete All As Specified And Directed. 29 S&F For Steel Windows With Side Hung Shutters Including Projecting Type Hinges With Steel Handle, Guards Bars And Steel Peg Stay, Complete With Glazing Bars, Dovetailed Or Welded And Received Glass Sheet Complete, All As Specified And Directed By E / I. 30 Supply Of 4.8 Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square N Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed. 31 S&F 100Mm Size Butt Hinges, Heavy Weight, Cold Rolled Mild Steel, And Fixed Complete All As Specified And Directed. 32 S&F 50Mm Size Butt Hinges, Heavy Weight, Cold Rolled Mild Steel, And Fixed Complete All As Specified And Directed. 33 S&F 150Mm Size Aluminium Alloy Handles, Fabricated Type, Anodised Complete All As Specified And Directed. 34 S&F 300 Mm Long Aluminium Anodised, Barrel Tower Bolts Of Ex-Truded Section And Fixed Complete All As Specified And Directed. 35 S&F 250Mm Long Aluminum Alloy, Anodised Sliding Bolt With Hasp Stable Bolt Type Stove Enameled Black, With Bright Bolt Not Less Than 12Mm Dia And Including A Minimum 06 Nos Bolts And Nutls. Complete All As Specified And Directed. 36 M&L For 25 Mm Thick Cement Concrete Type B-0, 1:2:4 ( 12.5Mm Graded Aggregate ) Below Tiles Work Complete All Specified And Directed. 37 S&F Kota Stone Slab 20-25Mm Thick In Riser Of Steps, Skirting, Dado And Pillar Laid Over Cement Screed And Jointed. 38 S&F 110 Mm Dia Pvc ( Swr ) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Walls 39 S&F Grating Doom 100Mm Dia Of Ptmt ( Minimum Weight 40Gms ) Complete All As Specified And Directed. 40 S&F 110Mm Dia Pvc ( Swr ) Bends Anyradiuscomplete All As Specified And Directed 41 M&L For Point Writing For One Light / Fan Point, 3 / 5 Pin Socket Outlet Independent / Bell Or Buzzer Point / Telephone Point Controlled By One Switch With Cable 1.5 Sqm Size Pvc Suface Conduit Nsulated ( Unsheathed ) 1100 Volts Grade Single Core Staded ( Multistred ) Copper Conductor Frls Cable As Per Is-694 And Drawing In And Including Ivc Suitable Conduct Medium Grade Not Less Than 20Mm Dia And Sunk Cast Iron Terminal Boxes For Mounting Fittings, Light Switches, Sockets With 3Mm Thick Bakelite Laminated Sheet With Brass Screws And Cup Washers Including One Continuous Run Of 1 Sqmm Nominal Area Pvc Insulated Unsheathed 100 Volts Grade Signle Core Fr Cable Conform To Is-694 With Stranded Copper Conductor ( Multistranded ) Green Colour Earth Wire And Connecting To Earth Dolly Complete All As Specified And Directed.-Make Ofhavells, Fenolex, Pllaza 42 M&L For Point Writing For One Light / Fan Point, 3 / 5 Pin Socket Outlet Independent / Bell Or Buzzer Point / Telephone Point Controlled By One Switch With Cable 2.5 Sqm Size Pvc Suface Conduit Nsulated ( Unsheathed ) 1100 Volts Grade Single Core Staded ( Multistred ) Copper Conductor Frls Cable As Per Is-694 And Drawing In And Including Ivc Suitable Conduct Medium Grade Not Less Than 20Mm Dia And Sunk Cast Iron Terminal Boxes For Mounting Fittings, Light Switches, Sockets With 3Mm Thick Bakelite Laminated Sheet With Brass Screws And Cup Washers Including One Continuous Run Of 1 Sqmm Nominal Area Pvc Insulated Unsheathed 100 Volts Grade Signle Core Fr Cable Conform To Is-694 With Stranded Copper Conductor ( Multistranded ) Green Colour Earth Wire And Connecting To Earth Dolly Complete All As Specified And Directed.-Make Ofhavells, Fenolex, Pllaza 43 Supply And Fixing For Each Additional Light Point On The Same S W I T C H - Circuit Complete All As Specified And Directed. 44 Supply And Fixing One Light Point Controlled By Two 2 - Ways Switches With Cables 1.5 Sq. Mm Size Complete All As Specified And Directed. 45 Supply And Fixing Switch Piano Flush Button Single Pole One Way 5 Amps Complete All As Specified And Directed. 46 Supply And Fixing Socket Outlet 5 Pin 5 Amps Surface Type Controlled By One Switch Complete All As Specified And Directed. 47 Supply And Fixing Socket Outlet Combined Multipurpose 5 Pin, 5 / 15 Amps Controlled By One Switch Complete All As Specified And Directed. 48 S&F Lamp Holder Insulated Body With Back Plate 5 Amps Suitable For Batten Fittings ( Angle Plain ) Complete All As Specified And Directed. 49 S&F Pendant Ordinary, Comprising Ceilingrose, Brass With Insulated Body Lampholder, Cord Grip Pattern, And 0.5 Sq.Mmcopper Flexible Twisted Twin Cord Up To1.5M Length As Ordered 50 S&F Single Pole & Neutral1, 8 Way Db Enclose Double Door Complete All As Specified And Directed. Mcb 5 To 30 Amp Single Phase 12 Nos Dp Single Phase 40Amp 3 Nos- Make- Havells 51 Supply And Fix Ceiling Fan Made Of Sturdy Engineering Plastic Complete With Louvers Shutter, Voltage 230V, 50 Hz, Rpm 1200, Copper Winding Of Sweep 250 Mm Complete All As Specified And Directed. 52 Supply And Fixing Ceiling Fan Regulator Electronic Type 5 Stage Speed Variation Isi Marked Complete All As Specified And Directed. 53 Supply & Fixing Single Pole Mcb 10 To 40 Amp. Complete All As Specified And Directed. 54 Supply & Fixing Isolator Double Pole 40 Amp.Complete All As Specified And Directed.. 55 Supplying And Fixing 1100 Volts Grade Heavy Duty, 10 Sqmm 2 Core Cable Pvc Insulated Aluminium Stranded Conductor, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Mater Aprt Including 4Mm Dia, Gi Suspensions Wire, Two Single Core Cable Falt Or Circular Complete All As Specified And Directed. 56 S&F Earthing Complete With Galvanisedsteel Earth Plate Electrode60×60Cm.X6mm Thick, Burieddirectly In Ground ( Earth Pit Not Lessthan 2.25 Metres Deep Below Groundlevel ) With Top Edge Of The Plate NotlessThan 1.5 Metres Below Normalground Level, Connected Togalvanised Earth Lead Wire 4.0Mmdia By Means Of Bolts, Nuts, Checknuts And Washers Of Galvanised Ironor Steel All As Shown In Electricalplate No. 5 Connected To Earthing Testpoint All As Specified Or Indicatedincluding Testing On Completion Complete All As Specified And Directed.

Key Value

Document Fees
INR 1000 /-
EMD
INR 99900.0 /-
Tender Value
INR 49.94 Lakhs /-

BOQ Items

Name of Work: CONSTRUCTION OF DISASTER MANAGEMENT SHED FOR PUBLIC UTILITY IN MUSEUM PREMISES AT GLR SY. NO. 118(PART)
Sl. No. Item Description
1Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. exc 10 sq m on plan and n exc 1.5 m in depth and getting out
2M&L cement concrete in foundations type D-2 1:4:8(40 mm graded aggregate) filling and mass concrtete.
3M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter finished surface fair and even complete allspecified and directed.
4M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions finished surface fair and even complete allspecified and directed.
5M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) finished surface fair and even complete all specified and directed.
6M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. finished surface fair and even complete allspecified and directed.
7M&L for RCC work with cement approved corse sand and 20mm graded aggregates approved stone ballast confirming M-20 mixed in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete excluding steel reinforcement and formwork complete all specified and directed.
8M&L for RCC work with cement approved corse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed inColumns, pillars, piers, posts and struts excluding steel reinforcement and formwork complete all specified and directed.
9M&L for Earth filling back side wall alongwith flooring portion, including, spreading and levelling, including, watering, well ramming etc in layers and exc 25cm thick and rough excavated material lead exc 1.5 KM but n exc 5 KM depositing where directed.
10M&L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
11M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all specified and directed.
12M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all specified and directed.
13M&L for RCC work with cement approved corse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves excluding steel reinforcement and formwork complete all specified and directed.
14M&L for RCC work with cement approved corse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed inBeams, cantilevers, bressummers, lintels over 1.5m span excluding steel reinforcement and formwork complete all specified and directed.
15M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean substructure radius built in cement motar 1:6 complete all specified and directed.
16M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean superstructure radius built in cement motar 1:6 complete all specified and directed.
17M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete allspecified and directed
18M&L for TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipsas in reinforcement complete allspecified and directed.
19M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in (1:4 cement mortar)
20M&L for 12mm thick cement plastring in 1:6 cement motar on fair faces of brick work or concrete surface finished even and smooth without using extra cement on internal surface complete allspecified and directed.
21M&L for 12mm thick cement plastring in 1:6 cement motar on fair faces of brick work or concrete surface finished even and smooth without using extra cement on outer surface complete allspecified and directed-other than fair surface
223mm thick wall care putty on wall
233mm thick wall care putty on ceiling
24M&L forDistemper paint- i.e. applying two coat of interioremulsion paint (appeex) and preparation of newly plastered surface interiorside, Ceiling complete all specified and directed
25M&L for two coat plastic emulsion paint and preparation of newly plastered surface of wall for external side complete all specified and directed by E/I.
26Supply & fixing 30mm thick flush shutter solid core construction with particle board core & plywood face with decorative face veneer with lipping frame to match
27M&L for preparation of new steel and iron surface of any description over 10cm width as girth and applying two coat of synthetic enamel paint over coat of red oxide primer complete all as specified and directed
28M&L for 125× 60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed.
29S&F for Steel windows with side hung shutters including projecting type hinges with steel handle,guards bars and steel peg stay, complete with glazing bars, dovetailed or welded and received glass sheet complete, all as specified and directed by E/I.
30Supply of 4.8 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane complete all as specified and directed.
31S&F 100mm size Butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified and directed.
32S&F 50mm size Butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified and directed.
33S&F 150mm size aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
34S&F 300 mm long Aluminium anodised,barrel tower bolts of ex-truded section and fixed complete all as specified and directed.
35S&F 250mm long aluminum alloy, anodised sliding bolt with hasp stable bolt type stove enameled black, with bright bolt not less than 12mm dia and including a minimum 06 Nos bolts and nutls. Complete all as specified and directed.
36M&L for 25 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) below tiles work complete all specified and directed.
37S&F Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed.
38S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls
39S&F Grating doom 100mm dia of PTMT(Minimum weight 40gms)complete all as specified and directed.
40S&F 110mm dia PVC (SWR)bends anyradiuscomplete all as specified and directed
41M&L for point writing for one light/fan point, 3/5 pin socket outlet independent/bell or buzzer point/telephone point controlled by one switch with cable 1.5 Sqm size PVC suface conduit nsulated (unsheathed) 1100 Volts grade single core staded (multistred) copper conductor FRLS cable as per IS-694 and drawing in and including IVC suitable conduct medium grade not less than 20mm dia and sunk cast iron terminal boxes for mounting fittings, light switches, sockets with 3mm thick Bakelite laminated sheet with brass screws and cup washers including one continuous run of 1 Sqmm nominal area PVC insulated unsheathed 100 Volts grade signle core FR cable conform to IS-694 with stranded copper conductor (multistranded) green colour earth wire and connecting to earth dolly complete all as specified and directed.-make ofhavells,fenolex, pllaza
42M&L for point writing for one light/fan point, 3/5 pin socket outlet independent/bell or buzzer point/telephone point controlled by one switch with cable 2.5 Sqm size PVC suface conduit nsulated (unsheathed) 1100 Volts grade single core staded (multistred) copper conductor FRLS cable as per IS-694 and drawing in and including IVC suitable conduct medium grade not less than 20mm dia and sunk cast iron terminal boxes for mounting fittings, light switches, sockets with 3mm thick Bakelite laminated sheet with brass screws and cup washers including one continuous run of 1 Sqmm nominal area PVC insulated unsheathed 100 Volts grade signle core FR cable conform to IS-694 with stranded copper conductor (multistranded) green colour earth wire and connecting to earth dolly complete all as specified and directed.-make ofhavells,fenolex, pllaza
43Supply and fixing for each additional light point on the same s w i t c h - circuit complete all as specified and directed.
44Supply and fixing One light point controlled by two 2 - ways switches with cables 1.5 sq. mm size complete all as specified and directed.
45Supply and fixing switch piano flush button single pole one way 5 Amps complete all as specified and directed.
46Supply and fixing socket outlet 5 pin 5 Amps surface type controlled by one switch complete all as specified and directed.
47Supply and fixing socket outlet combined multipurpose 5 pin, 5/15 Amps controlled by one switch complete all as specified and directed.
48S&F lamp holder insulated body with back plate 5 Amps suitable for batten fittings (angle plain) complete all as specified and directed.
49S&F Pendant ordinary, comprising ceilingrose, brass with insulated body lampholder, cord grip pattern, and 0.5 sq.mmcopper flexible twisted twin cord up to1.5m length as ordered
50S&F Single pole & neutral1, 8 way DB enclose double door complete all as specified and directed. MCB 5 to 30 Amp single phase 12 Nos DP single phase 40Amp 3 Nos- make- HAVELLS
51Supply and fix ceiling fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed.
52Supply and fixing ceiling fan regulator electronic type 5 stage speed variation ISI marked complete all as specified and directed.
53Supply & Fixing single pole MCB 10 to 40 amp. complete all as specified and directed.
54Supply & Fixing isolator Double pole 40 amp.complete all as specified and directed..
55Supplying and fixing 1100 volts grade heavy duty, 10 Sqmm 2 core cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mater aprt including 4mm dia, GI suspensions wire, two single core cable falt or circular complete all as specified and directed.
56S&F Earthing complete with galvanisedsteel earth plate electrode60×60cm.x6mm thick, burieddirectly in ground (earth pit not lessthan 2.25 metres deep below groundlevel) with top edge of the plate notless"than 1.5 metres below normalground level, connected togalvanised earth lead wire 4.0mmdia by means of bolts, nuts, checknuts and washers of galvanised ironor steel all as shown in electricalplate No. 5 connected to earthing testpoint all as specified or indicatedincluding testing on completion complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy