Tender For Provn Of Drainage Water System For Cadets Living Accn , Special Repair Of Bldg No 50 (Quarter Gard) And Provn Of Parking Shed Area With Shed Near Bldg No 52 (Main Office) At Ncc Ota, Kamptee Under Ge Kamptee., kamptee-Maharashtra

Military Engineer Services-MES has published Tender For Provn Of Drainage Water System For Cadets Living Accn , Special Repair Of Bldg No 50 (Quarter Gard) And Provn Of Parking Shed Area With Shed Near Bldg No 52 (Main Office) At Ncc Ota, Kamptee Under Ge Kamptee.. Submission Date for this Tender is 10-01-2024. Building Work Tenders in kamptee Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

41028638
Corrigendum : Tender For Provn Of Drainage Water System For Cadets Living Accn , Special Repair Of Bldg No 50 (Quarter Gard) And Provn Of Parking Shed Area With Shed Near Bldg No 52 (Main Office) At Ncc Ota, Kamptee Under Ge Kamptee.
Open Tender
Indian
Maharashtra
kamptee
10-01-2024

Tender Details

Provn Of Drainage Water System For Cadets Living Accn , Special Repair Of Bldg No 50 ( Quarter Gard ) And Provn Of Parking Shed Area With Shed Near Bldg No 52 ( Main Office ) At Ncc Ota, Kamptee Under Ge Kamptee.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Dec-2023 Corrigendum 01 BOQ 30-12-2023
2 30-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-01-2024
3 08-Jan-2024 Corrigendum 02 Date 10-01-2024
4 08-Jan-2024 Corrigendum 03 Technical Bid 10-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 99680.0 /-
Tender Value
INR 49.84 Lakhs /-

BOQ Items

Name of Work: PROVN OF DRAINAGE WATER SYSTEM FOR CADETS LIVING ACCN ,SPECIAL REPAIR OF BLDG NO 50 (QUARTER GARD) AND PROVN OF PARKING SHED AREA WITH SHED NEAR BLDG NO 52 (MAIN OFFICE) AT NCC OTA, KAMPTEE UNDER GE KAMPTEE.
Sl. No. Item Description
1Dismantling floor, hearth or wall tiling including cement mortar beddeing (but not backing), removing serviceable tiles to store and debris complete all as specified and as directed.
2M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding. 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15 mm thick screed bed of cement mortar (1:6) etc complete all as specified and as directed.
3All as item No 02 above but as in skirting with 10mm backing in cement mortar 1:4 complete all as specified and as directed.
4Material & labour for glazed ceramic coloured tiles 300mm x 450mm, on vertical surface such as skirtings/dados set and jointed in neat cement slurry and pointed in coloured cement to match and incl.10mm thick backing coat in CM 1:3 finished even and fair complete all as specified and as directed.
5Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets any thickness and wall paneling including cover fillets,complete all as specified and directed.
6M&L for 4mm thick Non Asbestos, fibre cement building board of size 595x595mm size in ceiling fixed or laid/ inserted including GI powder coated snap grid framework for false ceiling comprising of the following section for making partition of 600x600 mm size fixed to wall with rawl plug and screw and hanged to roof with 4 mm dia GI suspended wire of suitable length and butterfly clip of size of main Tee shall be 32mmx15mmx0.30mm, cross tee shall be 32mmx15mmx0.30mm thick with black lining in mid portion and wall angle shall be 24mmx24mmx0.30mm thick complete all as specified and directed
7Taking down existing water proofing treatment including PCC padding, mortar etc and disposal of rubbish outside of MD land and hacking for key, scrubbing down with water complete all as specified and directed.
8M&L for provision of water proofing treatment by using APP torch on non woven polyster film reinforcement with 3 mm thick and weight not less than 3.00 kg/sq m over roof and vertical surfacesincluding preparation of surfaces and applying oil based bituminous primer coat @ 0.30 ltr per sqm on clean and dry surface and then providing APP membrane laid with 100 mm over lap on both sides all as per manufacturer"s instructions including 15mm thick cement plaster in CM 1:4 with WPC and two coat of aluminium paintof 0.2Kg/Sqm over membrane complete all as specified and directed.
9Demolition of RCC of any description and in any position not otherwise specifically provided forcomplete all as specified and directed.
10M&L for providing cement concrete 1:4:8 type D2 (Using 40mm graded stone agg) in foundation, mass concrete and filiings complete all as specifiedand directed.
11M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed.
12All as per item No 11 above but 6 to 8 mm dia complete all as specified and directed.
13Providing precast cement concrete Type B1 1:2:4 (20mm graded aggregate) set in CM 1:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas,water roughs,mangers , shelves and similar articles with plain faces, complete all as specified and directed.
14Demolition of Stone slabs & tiles of any description or thickness in floors, aprons etc. Laid, bedded & pointed in any mortar complete all as specified and directed.
15S&F pre-polished granite 20mm thick fixed on platform/shelves/steps/cill over 20mm thickscreed bedin cement mortar 1:4 including necessary moulding etc complete all as directed.
16M&L Machine cut cudappah stone slab 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and directed.
17Demolition of cement concrete any description and in any position not otherwise specifically provided forcomplete all as specified and directed.
18M&L 75 mm thick cement concrete type C-2, 1:3:6 (40 mm graded aggregate) finishing cement concrete surface even and smooth without using extra cement as in plinth protection complete all as spd and directed.
19M&L Pre polished Chequered tiles rubber pressed glossy finish (any colour) 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment including 20mm screed bedding in cement mortar (1:4)complete all as specified and as directed.
20Demolition of brick work, built in cement mortar or cement lime mortar including all quoins, pillars etc. and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 50m complete all as specified and as directed.
21M&L for brick with fly ash brick old size straight of curved on plan exc 6 m mean radius built in CM 1:6complete all as specified and as directed.
22All as per item No 21 here-in-above but half brick wall in CM 1:4 complete all as specified and as directed.
23M&L Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3, complete all as specified and directed.
24S&F wire netting of galvanised steel wire 0.71 mm dia and size of mesh is 12 mm fixed in properly with suitable nails for repair of cracks at various locations in wall, beam,chajja, facis, slab, lintel etc including taking down plaster of cracked portion and making good the area by rendering in CM 1:3 complete all as specified and directed.
25Taking down cement Plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of debris, complete all as specified and as directed
26M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces with CM 1:6 on internal walls finished even and smooth (without using extra cement) complete all as specified and directed.
27M&L Rendering 15 mm thick on fair faces of brick work or concrete surfaces inCM 1:6 finished fair and even complete all as specified and directed.
28M&L rendering 15mm thick on brick work or concrete surfaces with CM (1:4) finished fair and even complete all as specifed and directed.
29Material & labour for Rendering 15 mm thick on brick or concrete surfacesin CM 1:4using water proofing liquid compound as per manufacturer instructions, and finished fair and even complete all specified and directed.(WPC shall be measured and paid separately.)
30Supply only liquid water proofing compound complete all as specified and directed.
31M&L Rendering 5 mm thick on fair faces of brick work or concrete surfaces with CM 1:3 on ceiling surfaces finished even and smooth (without using extra cement) complete all as specified and directed.
32M&L for Rendering dubbing coat over damaged irregular surface of chajjas roof projections/ ceiling/ facia etc average 15mm thick in cm 1:4 over cement slurry coat thick @ 3 Kg/sqm making the surface even followed by 5mm thick rendering in CM 1:3 furnished even& smooth including making of drip course as reqd completeincl roughening surface of old concrete by picking sweeping clean and washing with water all as specified. Note :Rate for form work if reqd to be incl in the rate quaoted by the contractor.
33Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including prepration of surfaces complete all as specified and directed
34M & L for prepartion of new plastered surface of wall and applying two coats of oil bound distemper over a coat of Primer over a coats of wall care putty complete all as specified and directed.
35M&L for preparing newly plastered walls surfaces and applying threecoats White washoverwall surfaces all as specified and directed
36M&L for applying three coats of white wash on undecorated ceiling surfaces complete all as specified and directed.
37M&L complete removal of existing treatment of old plastered surfaces on wall including brooming down or steel wire brushing,scraping down moulds , washing downincluding filling cracks and holes and applying two coats of oil bound distemper over a coat of wall care putty including scaffolding etc complete all as specified and directed.(Note:- applied by Roller only)
38M&L for applying one coat of white wash on old decorated ceiling surfaces complete all as specified and directed
39Taking down door / window frame with shutter (without taking of shutter from the frame )area n. exc 1.50 sqm complete all as specified and directed.
40Taking down door / window frame with shutter (without taking of shutter from the frame )area exc 1.50 sqm but not exc 4 sqm complete all as specified and directed.
41Taking down shutter of any description exc 1 Sqm but not exc. 2 Sqm each and removing from site complete all as specified and as directed.
42Supply & fixing 30mm thick 2nd class hard wood factory made Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), kiln seasoned and chemically pressure treated complete all as specified and as directed.
43Supply and fixing second class hard wood 35mm thick factory made Plain framed, paneled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
44Supply and fix aluminium (colour powder coated ) three track sliding window comprising of one fly proof shutter and two glazed shutters with frames of size 92.0mm x 31.75mm x 1.30mm thick and shutter frames of size 40mm x 18mm x 1.55mm thick with necessary joining cleats, glazing clips, rubber gasket, anodised aluminium snap beading and connected locking arrangement(Notes : (i) Glass filling in panels of windows and aluminium wire mesh/wire cloth shall be deemed to be included in the quoted rate for the item;(ii) Aluminium alloy wire cloth in panels of wire gauzed shutter shall be 0.45 mm nominal dia of wire and avg width of aperture 1.40 mm, fixed with aluminium wire staples; (iii) Glass filling in panels of glazed shutter shall be 5 mm thick tinted sheet glass of approved make and shade/tint
45S&F colour powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
46S&F colour powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21100mm long (2 no.) suitable handle (1no.) complete all as specified and directed.
47S&F 4 mm thick figured (frosted) glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete.
48S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
49S & F 100 mm long SS butt hinges and fixed with screw/welded to frames etc all as specified and as directed by EIC
50Supply & fixing 150mm Aluminium barrel tower bolts, fixed complete all as specified and as directed
51Supply & fixing 125 mm Aluminium pressed handles fixed complete all as specified and directed.
52S & F 250 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed complete all as specified and directed.
53Material & labourfor preparation of new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
54M&L for preparation of old steel surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint etc complete all as specified and directed.
55Preparation of newly steel surfaces of any description over 10 cm width or girth andapplying two coats synthetic enamel paint over a coat of red oxide primer.complete all as specified and directed
56M & L for PCC 1:2:4, Type B0 (using 12.5 mm graded stone aggregate) 25 mm thick as infloor complete all as specified and directed.
57M&L for fixing of snake guard made of aluminum/steel colored coated 40 mm wide with nails to cover the gapes between door and floor and similar places
58M&L for Post Construction ATT Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron,etc complete all as specified and directed.
59M&L for Treatment of soil under existing floors using emulsion @ one litre per hole,300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified and directed.
60M&L for Grouting in Brick/RCC/ wall/floor/roof through PVC nipples at a spacing of 45 to 60 cm C/C including drilling injuction points to a depth of 75-100mm, providing 10mm dia PVC nipples and pressure grouting using with and including cement mixed with plasticizer admixture like FOSROC (model CEBEX100) or PIDILITE (MODEL 207 PIDICRET 8AM) @ 225GMS/50kGS of cement to fill up all capilaries/voids/honecombing, nozzles to be sealed with sealing with pressure of 2 to 4 kg/sqcm and continued till refusal. After instructions complete all as specified and directed. (Note:- After ascertaining the location of leakage/seepage/dampness under relevant item shall be operated of the required location.)
61Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, SmartCare Damp Block 2K Supremo or approved equivalent, having 80% elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per ASTM C 1202, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. applying SmartCare Damp Block 2K Suprema in two coat 2 kg/sqmt consumption, The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing , etc, complete as per manufacturers specifications.
62M&L for cement concrete type B0, (1:2:4) (using 12.5mm graded stone aggregate) as in benching/coping and the like including weathering slightly round or chamfered angles and throatingcomplete all as specified and directed.
63S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165
64M&L for Preparing surfaces of wood and wood based materials,new or old, of any description and girth, not otherwise described and treated with one coat of Creosote, complete all as specified and directed.
65Excavation in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm, watering and removing surplus soil to distance n.exc 50m and making good surface in soft/loose soilcomplete all as specified and directed .
66Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed .
67Excavation in trenches n exc 1.5m in deepth and 1.5m in widthand getting out in any type of soil complete all as specifiedand directed.
68Excavation in trenches exc 1.5m but n.exc 3.0m in deepth and 1.5m in widthand getting out in any type of soil complete all as specifiedand directed.
69Excavation over areas not exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
70All as per item No. 69 here in before but depth exc 1.5 m and n. exc 3.0 m deep complete all as specified and directed.
71Returning, filling in,including spreading, levelling, watering and well ramming in layers not exc. 25cm in soft/loose soil complete all as specified and directed
72Removing excavated material exc 250 m but not exc 500 m and depositing where directed as in soils complete all as specified and directed
73Removing excavated material (soil)n .exc 50m and deposited where directed at a level n exc. 1.5m above the strating point complete all as specifiedand directed.
74M&L cement concrete type B2, 1:2:4( 40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
75S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
76s&f Pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
77S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tube conforming to IS 1161-1979 grade St-240 complete all as specified and directed
78M&L Mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming toFe-410W Gde E-250 quality B all as specified and directed.
79S&Ffor 11 to 15 mm mild steel screws bolts (machine made) with hexagonal or square heads at one end and screws both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm not exc 10 cm long complete all as specified and directed.
80S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plate, riveting, etc n.exc 10 kg each brackets, conforming to Fe-290. Gde E-165 .complete all as specified and directed
81M&L hardcore broken stone or boulders of gauge n.exc. 63mm deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface for path complete all as specified and directed.
82M & L for 75mm thick PCC 1:2:4 type B1 using 20 mm graded stone aggregatesas in floor finished the surface even and smooth without using extra cement complete all as specified & directed.
83M&L 38mm wide and 3mm thick glass dividing strips inserted in position confirmed to designed complete all as specified.
84Material & labour preparation of newly plastered surfaces of wall & applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
85M&L for cement concrete 1:2:4 type B-1(using 20mm graded aggregate) as in roof kerbs or mud stops, steps, rounded or chamfered on edges complete all as specified and directed.
86M&L Cement concrete 1:2:4 type B1 using 20mm graded stone aggragate as in surface channels and drains complete all as specifed and directed.
87Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed.
88Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto complete all as specified and directed.
89Taking down cement or cement plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
90Cleaning of sludge/soil etc accumulated in existing drain and thrown away the spoil in low lying area exc 50m upto a distance of 250m complete all as specified and directed.
91S&F 300 mm diaReinforced concrete pipes, class NP2, laid and jointed complete with collars, laid in trenches or in floors complete all as specifed and directed.
92Taking down point wiring with aluminium conductor cable of light point fan & socket light & power complete including light fittings any type switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fitting, regulator etc, and making good to the disturbed surfaces of walls/ floor etc to macth with existing surfaces including white washing/colour washing/ distempering to match with existing wall/floor/ceiling finishes, complete all as specified and directed.
93Taking down sheet metal enclosure, DB & MCBsmain switch etc and making good distrubed sufaces to match with exisiting surfaces, complete all as specified and directed.
94Taking down sub main wiring of any size/ capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces, complete all as specified and directed.
95Material and labour for point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealedin wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmmmodular boxessunk on wall for mounting of any type modular switches, switch sockets, fan regulator etc includingmodular coverwith frame any size including dummy switches wherever required complete all as specified and making good disturbed surfaces including white/color washing as specified for one light point controlled by one, one way switch, complete all as specifed and directed. Note :- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate.All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
96All as per item Sl No 95 above but One ceiling/exhaust/wall fan point controlled by oneway switch and regulator, complete all as specified and directed.
97All as per item Sl No 95 above but One 3 pin 5 amp socket outlet point on the same board with other switches, complete all as specified and directed.
98All as per item Sl No 95 above butOne 3 pin 5 amps socket out let point on independent board, complete all as specified and directed.
99All as per item Sl No 95above but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmmfor 15 amps power point, complete all as specified and directed.
100Material and labour for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mmwith IS 9537 (Part-III) 1983 marked medium grade concealed inwall of the size 2x4.0 Sqmm with earth wire of 1x4.0 Sqmm, complete all as specified and directed. Note :- Accessories for point/sub main wiring like PVC junction box, bend, Tee, elbow shall be of same Make.
101Supply and fixing for switch modular type single pole one way 6 amp 1 module 250 volts AC suitable for modular switch boxes, complete all as specified and directed.
102Supply and fixing for socket modular type single pole one way 6 amp 2 module 2/3 pin 250 volts AC suitable for modular switchboxes, complete all as specified and directed.
103Supply and fixing for switch modular type single pole one way 6/16 amp 3 pin 250 volts AC suitable for modular switch boxes, complete all as specified and directed.
104Supply and fixing for socket modular type single pole one way 6/16 amp 2/3 pin 2 module, 250 volts AC suitable for modular switch boxes, complete all as specified and directed.
105S&F for switch modular type single pole one way 6 amp 1 module 250 volts AC suitable for modular switch boxes complete all as specified and directed.
106Supply and fixing ceiling rose, surface type, three terminals 5 amps, complete all as specified and directed.
107Supply and fixing0-4 step -2 module modular type electronic regulators for ceiling fan 1200/1400 mm sweep, 240 volts, 120 watts single pole complete all as specified and directed.
108Supplying and fixing 20 Watt LED Tube light fittings completewith aluminum body including tube rod, driver with not less than 2000 Lumen O/P andI/p rated voltage 240V connecting with3 core 1 sqmm copper conductor cable complete all as specified and directed.
109Supply and Fix Highly durable surface mounted 20 watts LED batten constructed of fire retardant engineering grade extruded aluminium body 100 lumen per watt and decorative end cap complete with tube rod,driver including 3 core 1.0 sqmm copper conductor cable for connection and accessories all as specified and directed
110Supply and fix building security lightLED25 W with Lumen O/P 1800 with driver withrated voltage 240 V, 50Hz,including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc. complete all as specified and directed.
111Supply & fixlight fitting 9W bulk head luminaries with lamp holders etc complete with all accessories and including connecting up with twin core twisted flexible cable suitable size of 230V, 50HZ complete all as specified and directed.
112Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed.
113Hanging only ceiling fan (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan complete after Painting of ceiling fans complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc all as specified and directed
114Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including taking down old fan complete all as specified and directed.
115Supply and fixsheet metal enclosure triple pole & neutral for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed.
116Supply and fix sheet metal enclosure single pole & neutral for 240 volts8 way with 200 Amp rated bus bar flush /surface mounting, double door, complete all as specified and directed.
117Supply and fix sheet metal enclosure IP 43 single pole & neutral for 240 volts4/6 way with 200 Amp rated bus bar flush /surface mounting, double door complete all as specified and directed.
118Supply and fix MCB Triple pole & neutral 240 volt40 to 63 amps 10 KA, complete all as specified and directed.
119Supply and fix MCB single pole 240 volt 6 to 40 amps 10 KA, complete all as specified and directed.
120Supply and fix MCB single pole and neutral240 volt 6 to40 amps 10 KA breaking capacity, "C" series, complete all as specified and directed.
121Earthing complete with galvanised steet earth plate electrode 600x600x6mm thick burried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr.below the normal ground level connected to galvanised earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified and testing on completion including the material and labour for :- (a) Excavation and earth work or drilling hole for electrode in any type of soil (b)PCC pit in cement concrete 1:2:4 TYPE B-1 (c)Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric (d)Funnel with watering pipe of GI 20mm nominal bore light grade and copper lugs etc all as specified. (e)15mm nominal bore meduim grade GI protec-tion pipe 7.50 metre long for protection of earthing lead. (f)Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion.
122NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs. 25,086.00]
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail