}

Tender For Repair To School/ Omq Buildings In Rv Area At Af Station Palam Under Ge (Af) Palam, Delhi Cantt-10, palam-Delhi

Military Engineer Services has published Tender For Repair To School/ Omq Buildings In Rv Area At Af Station Palam Under Ge (Af) Palam, Delhi Cantt-10. Submission Date for this Tender is 28-12-2023. Building Work Tenders in palam Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

41010773
Corrigendum : Tender For Repair To School/ Omq Buildings In Rv Area At Af Station Palam Under Ge (Af) Palam, Delhi Cantt-10
Open Tender
Indian
Delhi
Palam
28-12-2023

Tender Details

Tender For Repair To School / Omq Buildings In Rv Area At Af Station Palam Under Ge ( Af ) Palam, Delhi Cantt-10; 1 B / R Works Taking Down Cementplaster Of Any Description On Brick Or Stone Walls Etc Including Raking Out Joints Hacking For Key Scrubbing Down With Water Etc Removing Debries From Sites To Out Of Mod Land. 2 Demolition Of Brick Work / Stone Masonry Built In Cement Or Cement Lime Mortar Including All Quoins, Arches, Pillars Etc Of Any Description Including Removing The Debris From Site To Outside Mod Land. 3 Demolition Of Cement Concrete Of Any Discription And In Any Position Not Otherwise Specifically Provided For Including Removal Of Debris From Site To Outside Mod Land. 4 M&L For Brick Work With Sub Class B Works, Straight Or Curved On Plan Exceeding 6M Mean Radius, Built In Cement Mortar 1:6 Complete All Specified. 5 M&L For 15 Mm Thick Cementplaster On Fair Faces Of Brick Work Or Concrete Surfaces Of Walls In Cement Mortar 1:4 Including Finishing Surfaceeven And Fair Without Usingextra Cement . 6 M&L For 15 Mm Thick Cementplaster On Fair Faces Of Brick Work Or Concrete Surfaces Of Walls In Cement Mortar 1:6 Including Finishing Surfaceeven And Smooth Without Usingextra Cement . 7 M & L For 75Mm Thick Cement Concrete 1:3:6 Type C-2 Using 20Mm Graded Stone Aggregate As In Plinth Protection Including Finished Even And Smooth Without Using Extra Cement Including Making Joints 12 Mm Wide To The Full Depth Of Concrete At Every 3 Metres And At Every Change Of Direction And Filling The Same With & Including Bitumen85 / 25And Sand Inthe Proportion Of ( 1:3 ) By Weight Complete All As Specified. 8 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frames ) Area Not Exceeding 1.5 Sqm Each. 9 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frames ) Area Exceeding 1.5 Sqm And Not Exc. 4 Sqm Each. 10 Taking Down Shutter Of Any Discription Area Not Exc 1 Sqm Each. 11 Taking Down Shutter Of Any Discription Area Exc 1 Sqm And Not Exc. 2 Sqm Each. 12 M&Lforfactory Made Pressedsteelframe Fordoorwithoneor More Rebatedofsize105mmx 60 Mmwithnecessaryfixing Lugs, Hinges , Lockstrikeplate And Inserting Holdfasts Andmaking Good Dismantalled Portionin Cement Mortar ( 1:3 ) Or Cement Concrete ( 1:2:4 ) Type B-1 As Required Including Cement Concrete 1:2:4 Type B-0 Using 12.5Mm Graded Stone Aggregate In Back Filling Of Frame Etccomplete All As Specified. 13 S&F For 35Mm Thick Factory Made Flush Shutter, Solid Core Construction With Block Board Core And Plywood Face Panels, Commercial Type On Both Sides Complete All As Specified. 14 S&F For Butt Hinges, 100Mm Extruded Aluminium Alloy With Galvanised Mild Steel Hinge Pin, Anodised And Fixed, Type C-21. 15 S&F For Aluminium Anodised, Barrel Tower Bolts Of Extruded Section And Fixedof Size 150Mm. 16 S&F For Cast Type Anodised Aluminium Handles Of Size 150 Mm. 17 S&F For 300Mm Long Aluminium Alloy, Anodized, Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts Of Extruded Sections Or Cast Aluminium Alloy And Fixed Withscrews Complete All As Specified. 18 S&F For Anodised Aluminium Power Coated ( Minimum Thickness Of Powder Coating 50 Micron ) Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc All As Specified. 19 S&F For Anodised Aluminium Power Coated ( Minimum Thickness Of Powder Coating 50 Micron ) Window And Ventilator Shutters, Side Hung Type Without Sash Bar, Aluminium Section Weighing 0.55 Kg / M Including Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodisedaluminium Snap Beading, Screws Etc. And The Making Good Of Surface Such As Opening , Plastering Jambs, Levelling And Finishingcomplete All As Specified. 20 S&F For Aluminium Powder Coated ( Minimum Thickness Of Powder Coating 50 Micron ) Three Track Sliding Window With Mosquito Net Two Track For Glass Leaf Sliding And One Track For Mesh Leaf Sliding Outer Frame Weighing 0.699 Kg / M, 75Mm X 26 Mm Size, Shutter Plain Of Size 37.5Mm X 15Mm Weighing 0.366 Kg / M With One Or More Rebates, Sliding Type Without Sash Bars, 5Mm Thickness Double Tampered Clear Glass , Rubber Packing, Snap Beading Screws, With Horizontal Sliding Type Withstainless Steel Wire Cloth. 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm , Frame, Powder Coated Aluminium Grill Type Al-925 Or Its Equivalent Grill, Cutting In Suitable Size And Fitting With Screws And Suitable Beeding To Aluminum Window Frame Complete All As Specified. 21 M&L For Preparation Of Newlyplastered Surfaces Of Wall And Applyingtwocoatsofexterior Emulsion Paint With One Coat Of Wall Primer Over 2Mm Thick Wall Care Putty Completeall As Specified. 22 M&Lfor Complete Removalofexisting Treatmentof Old Decorated External Surface Of Walls By Electrically Operated Grinder Including Necessary Scaffolding Etcand Applyingtwocoatsofexterior Emulsion Paintwith One Coat Of Primer Over 2Mm Thick Wall Care Putty Completeall As Specified. 23 M&L For Preparation Of Newly Plastered Surface Of Walls Andapplying Two Coats Of Distemper Oil Emulsion Over A Coat Of Primer Including 2Mm Thick Wall Care Putty Complete All As Specified. 24 M&Lfor Complete Removalofexisting Treatmentof Old Decorated External Surface Of Walls By Electrically Operated Grinder Including Necessary Scaffolding Etcand Applyingtwo Coats Of Distemper Oil Emulsion Over A Coat Of Primer Including 2Mm Thick Wall Care Putty Complete All As Specified. 25 M&L For Preparation Of Newly Wooden Or Wood Based Surfaces Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer Complete All As Specified. 26 M&Lfor Preparation Of Old Painted Surfacesofwood& Wood Based Surfaces Ofanydescriptionnot Otherwisedescribedover10 Cmwidth&Girthand Applying Onecoatof Syntheticenamel Paintcompleteall Asspecified And Directedbyengr-In Charge. 27 S&F In Repair Steel Work In Tubular / Square / Rectangular Hollow Section / Angle Iron, Tee Etc. For Structural Trusses Including Special Shaped Washer Etc.Complete Using Erw Or Induction Butt Welded Tubes Conforming To I S : 1161-1979 Grade St.-24 Including Necessary Machinery Upto 10M Height Structure Complete All As Specified. 28 S&F In Repair Mild Steel Work Framed Work Such As Grills, Gratings, Etc.. With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framedbalusters; Walk Ways; Railings; Framework Of Water Tanksand Similar Work Conforming To Fe.290.Gde-E-165. 29 Dismantling Of Asbestos Cement / Steel ( Corrugated, Semicorrugated Etc. ) Sheets In Roof Covering, Ridge Etc Complete All As Specified. 30 S&F For 0.50Mm Pre- Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws As Specified. 31 S&F For 0.50Mm Pre- Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws As Specified. 32 M&L For Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer On Newly Steel Surface Of Any Description Over 10Cm Width Or Girth Including Preparation Of Surfaces Complete All As Specified. 33 M&L For Applying Two Coats Of Synthetic Enamel Paint On Old Concrete And Plaster Surfaces Of Any Description Over 10Cm Girth Or Width Over A Coat Of Primer Including Necessary Preparationall As Specified. 34 S&F In RepairE Boardceiling 4Mm Thick With Giframedwork With Main Tee Of Size24mm X 28.5Mm Made Out Ofpgisheet0.3Mm Thick Doubledatweb Andsingle Atflange.Flanagecovered With Powder Coated Sheet 0.35Mm Thickand Wailangles 24Mm X 24Mm X 0.3Mm Powder Coatedforceiling, Ceilingboard60cmx60cmx4.00Mm Thick, Suspended With Gi Wire2.24 Mm Diasand Lengthasrequired@ 600Mm C / C Withadjustabledevicecompleteincluding Plugging In Brick / Concrete Work With Steelrawplug @ 600 Mm C / C Andapplying Twocoatsofobd Over A Coat Of Primer On Ceiling Board.Ceilingboardshall Be Pressed To The Ceiling Tee With Staple Clips Atallfoursides All As Specifed And Directedincluding Makinggood Allthe Disturbedportion Complete All Asspecified And Directed. 35 Dismantling Of Timber Scantlings Of 40 Sqcm And Over In Section, In Any Position Complete All As Specified. 36 S&F For Second Class Hard-Wood Timber, Clean Swan, In Scantling On The Solid Rounded Or Chamfered Put Together With Glue Pinned At Joints Complete All As Specified. 37 M&L For 60Mm Thick Factory Made, Machine Pressed With Grey Cement And No Pigment Interlocking Paver Blocks Of Any Size And Shape Conforming To Is 15658-2006 Of Grade M-35 Concretecomplete Over And Including 25Mm Thick Sand Cushion Complete All As Specified. 38 M&L For75 Mm Thick Cement Concrete 1:4:8 Type D-2 Using 40 Mm Graded Crushed Stone Aggregate As In Sub Basecomplete All As Specified. 39 M&L For Galvanised Iron Z Section Of 2Mm Thick Fixed On Existing Rafter By Self Drilling Screws Zylem Coated With Rubber And Metal Washer Including Dismantling Of Existing Wooden Purlin, Rafter Etc Complete All As Specified. 40 E / M Works Taking Down Carefully Copper / Aluminium Point Wiring ( Light, Fan, Socket Or Power ) Complete Including Making Good Disturbed Surface Of Walls, Floors Etc Complete All As Specified. 41 M&Lforpoint Wiring Complete With 1.5 Sqmm ( Nominal Area ) Frls Pvc Insulated, Multi Stranded, Copper Conductor Cable Unsheathed Includingpvc Conduit And Fittings, Medium Grade, Isi Marked And Pvcinsulated Copperconductor Cable Of Size 1.5 Sqmm As Earth Wire , Connected To Common Earth Dolly Suitable Formounting Modular Switches Including Modular Metal Flush Box And Modular Face Plate With Frameincludes Cutting Of Chasis And Making Good Disturbed Surfaces All As Specified And As Directed By Engr-In-Charge For A Light Points / Fan Point Etc Complete. 42 All As Per Item No 41 Above But For 5 Amp Socket Point On Same Board Complete All As Specified. 43 All As Per Item No 41 Above But For 5 Amp Socket Point On Independent Board Complete All As Specified. 44 All As Per Item No 41 Above But For One 6 Pin Socket Out Let 15 Amps On Independent Board With Cables 2.5Sq Mm Size And Earth Wire 2.5 Sqmm Complete All As Specified. 45 M&L In Repair Modular Switch 1 Way 6 Amps 1 Module Complete. 46 M&L In Repair Modular Switch 1 Way 16 Amps 1 Module Complete. 47 M&Lin Repairmodular Socket Outlet 6A, 2 / 3 Pin Combined 2 Module Complete. 48 M&Lin Repair Modular Socket Outlet 6A / 16A, 2 / 3 Pin Combined 2 Module Complete. 49 S&Fin Repair Mcb SpC Series 6 To 32Amps Having Breaking Capacity 10Ka. 50 S&Fin Repair Mcb SpnC Series 32 Amps Having Breaking Capacity 10Ka. 51 S&Fin Repair Mcb Four Pole C Series 100 Amp 415 Voltsbreaking Capacity 10 Ka. 52 Taking Out Old Unserviceable Submain Wiring Of Any Size Complete All As Specified. 53 M&Lfor Sub Main Wiring With Multistranded Copper Conductor Cable Frls Pvc Sheathed In And Including Concealed Steel Conduit And All Fittings Medium Grade With Two Runs Of2.5 Sq Mm And One Run Of 2.5 Sq Mm Flexible Copper Wire As Earth Wire And Connected To Earth Dollyincludingchasing, Cutting And Making Good The Disturbed Surfacesas Specified. 54 M&Lfor Sub Main Wiring With Multistranded Copper Conductor Cable Frls Pvc Sheathed In And Including Concealed Steel Conduit And All Fittings Medium Grade With Two Runs Of6.0 Sq Mm And One Run Of 6.0 Sq Mm Flexible Copper Wire As Earth Wire And Connected To Earth Dollyincludingchasing, Cutting And Making Good The Disturbed Surfacesas Specified. 55 M&Lfor Sub Main Wiring With Multistranded Copper Conductor Cable Frls Pvc Sheathed In And Including Concealed Steel Conduit And All Fittings Medium Grade With Two Runs Of4.0 Sq Mm And One Run Of 4.0 Sq Mm Flexible Copper Wire As Earth Wire And Connected To Earth Dollyincludingchasing, Cutting And Making Good The Disturbed Surfacesas Specified. 56 Taking Down Any Type Oflight Fitting Of Any Capacity Or Wattage Or Size Complete All As Specified. 57 S&F For Wall Mounted Led Integrated Batten, Nakshatra P Seriesof Capacity 20 Watt Complete With All Accesseries Making Connection Complete All As Speficied And Directed By Engr-In-Charge .Cat Part No Lttb4f20wled P / W Make C&S Or Its Equivalent In Philips / Havells. 58 S&F In Replacement Of Sheet Metal Enclosures For Tpn Distribution Boards 8Way 415 V, Having Ip 43 Protection, Double Door Flush Mounted. Having 200 Amps Bus Bar For Each Phase Assembly As Per Is 8623 All As Specified. 59 Supply And Fixing In Replacement Of Sheet Metal Enclosures For Spn Distribution Boards 4Way, Having Ip 43 Protection, Single Door Flush Mounted. Having 200 Amps Bus Bar For Each Phase Assembly As Per Is 8623 All As Specified . 60 Supply And Fixing In Replacement Sheet Metal Enclosures For Spn Distribution Boards 8Way, Having Ip 43 Protection, Single Door Flush Mounted. Having 200 Amps Bus Bar For Each Phase Assembly As Per Is 8623 All As Specified. 61 Supply, Installation And Testing For Maintenance Free Grounding ( Earthing ) System Complete Burried Directly In Ground Vertically ( Earth Pit Not Less Than 3 Mtr Below Ground Level ) By Making Bore Hole Of 100 Mm Dia For Inserting 01 No 17 Mm Dia Molecular Copper Bonded High Tensile Low Carbon Steel Circular Earth Electrode Of 3 Meter Length With Average Copper Thickness Of 200 Microns Alongwith Environmental Friendly Grounding Enhancing Compound And Heavy Duty ( Hdpe ) Pvc Pipe Cap All In Below Ground Level And Connected To Copper Strip 25 X 3 Mm Flat By Means Of Brass Metal Bolts , Nuts And Washers Etc Including Protection Pipe Of Gi 40 Mm Bore Med Grade Upto 7.5 Meter Length And Connection Of Earth Lead To Maintain Distribution / Lt Panel Board / Dg Set With Copper Lugs Complete All As Specified And Directed By Engineer In Charge. ( Note : The Rate For Necessary Earth Work , Pvc Pipe, Copper Strip And All Required Materials Shall Deemed To Be Included In Quoted Rate By Contractor And Nothing Extra Shall Be Paid On This Account ) . 62 Supply And Fixing In Replacement Ofmetal Plug And Socket With Mcb And Steel Enclosure Of Capacity 20 Amp, Spn, Mcb Metallic Complete All As Specified. 63 Taking Down Carefully Ceiling / Exhaust Fan And Re-Fixing The Same After Completion Of Job All As Speciifed And Directed By Engr-In-Charge. 64 S&F For 5.5Mm Thick Tinted Sheet Glass Of Selected Quality Fixed To Aluminium Frame Work All As Speciifed. 65 S&F Stainless Steel Wire Cloth 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture Not More Than 1.4Mm Fixed With Stainless Steel Wire Staples Complete All As Speciifed.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 21-12-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 69900.0 /-
Tender Value
INR 34.95 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail