Tender For Two Year Rate Contract For Supply Of Reagents With Its Calibrator And Control Kits For Department Of Biochemistry All India Institute Of Medical Sciences, Raipur, raipur-Chhattisgarh

All India Institute Of Medical Sciences-AIIMS has published Tender For Two Year Rate Contract For Supply Of Reagents With Its Calibrator And Control Kits For Department Of Biochemistry All India Institute Of Medical Sciences, Raipur. Submission Date for this Tender is 08-01-2024. Indicators and Reagents Tenders in raipur Chhattisgarh. Bidders can get complete Tender details and download the document.




Tender Notice

41008004
Tender For Two Year Rate Contract For Supply Of Reagents With Its Calibrator And Control Kits For Department Of Biochemistry All India Institute Of Medical Sciences, Raipur
Open Tender
Indian
Chhattisgarh
raipur
08-01-2024

Tender Details

Two Year Rate Contract For Supply Of Two Year Rate Contract For Supply Of Reagents With Its Calibrator And Control Kits For Department Of Biochemistry , Consumables & Reagents , Ana Hep2- (Ift) - Anti Nuclear Antibodies Screening Kit By Immunoflurescent A)Kit For Detection Of Anti-Nuclear Antibodies In Human Serum By Indirect Immune-Fluorescent Test System Utilizing Human Epithelial Cell Substrate Slides. B)Kit Should Contain Hep2 (Human Epithelial Cell) Substrate Slides: 12 Wells/Slide With Desiccant. C)Kit Should Contain Goat Anti-Human Igg Conjugate, Fluorescein (Fitc) Labeled In Buffer Containing Evans Blue. D) Kit Should Contain Ready To Use Positive Control (Preferably Homogenous Pattern) As Well As System Negative Control. E)Same Buffer Should Be Useable For Sample Dilution And Washing Purpose. F)Should Come With All Buffers And Accessories Like Mounting Media And Cover-Slips. G)Pack Size-20X12wells (20Glass Slides Of 12Wells Each) Per Pack / Maximum Pack Size Available. H) For Ivd Use. I)The Reagents To Be Supplied Must Have Expiry Of Minimum 06-08 Months. , Ana Profile 3 Plus (Ana Blot) Kit Specifications: A)The Test Kit Should Provide A Qualitative In Vitro Assay For Human Autoantibodies Of The Igg Class To At Least 16 Different Antigens: Nrnp, Sm, Ss-A (Native), Ro-52, Ss-B, Scl-70, Pm-Scl, Jo-1,Cenp B, Pcna, Dsdna, Nucleosomes, Histones, Ribosomal P-Protein, Ama M2 And Dfs70 Inserum Or Plasma Helpful For Differential Diagnosis Of Systemic Rheumatic Diseases. B)It Should Offer A Multiplex Approach For The Determination Of These Antibodies In A Single Reaction. C)The Antigens To Be Placed At Defined Positions On Membrane Strip. D) All Different Form Of U1snrnp (Rnp A, Rnp B, Rnp C) Should Be Coated In The Strip. E)All The Conjugate Reagents In The Kit Should Be Ready To Use. F)The Wash Buffer In The Kit Should Be Ready To Use. G)Interpretation Software Should Give Disease Interpretation As Well. H)Software Should Be User Friendly. I) Software Should Have The Function To Export The Results. J) Interpretation Software Should Support Any Kind Of Flatbed/Printer Scanner. K)The Result Should Be In Intensity (%) Index Value Format Provided With Range. L) For Ivd Use. M) Pack Size-Minimum Pack Size Must Be Quoted For Price Calculation. N) Expiry Of 6 To 8 Months Or More. Ana Profile 3 Plus (Ana Blot) Kit Specifications: A)The Test Kit Should Provide A Qualitative In Vitro Assay For Human Autoantibodies Of The Igg Class To At Least 16 Different Antigens: Nrnp, Sm, Ss-A (Native), Ro-52, Ss-B, Scl-70, Pm-Scl, Jo-1,Cenp B, Pcna, Dsdna, Nucleosomes, Histones, Ribosomal P-Protein, Ama M2 And Dfs70 Inserum Or Plasma Helpful For Differential Diagnosis Of Systemic Rheumatic Diseases. B)It Should Offer A Multiplex Approach For The Determination Of These Antibodies In A Single Reaction. C)The Antigens To Be Placed At Defined Positions On Membrane Strip. D) All Different Form Of U1snrnp (Rnp A, Rnp B, Rnp C) Should Be Coated In The Strip. E)All The Conjugate Reagents In The Kit Should Be Ready To Use. F)The Wash Buffer In The Kit Should Be Ready To Use. G)Interpretation Software Should Give Disease Interpretation As Well. H)Software Should Be User Friendly. I) Software Should Have The Function To Export The Results. J) Interpretation Software Should Support Any Kind Of Flatbed/Printer Scanner. K)The Result Should Be In Intensity (%) Index Value Format Provided With Range. L) For Ivd Use. M) Pack Size-Minimum Pack Size Must Be Quoted For Price Calculation. N) Expiry Of 6 To 8 Months Or More. , Dsdna (Quantitative/Semi-Quantitative) Kit Specifications: A) Polystyrene Micro-Well Elisa Plate Coated With Calf Thymus Dsdna Coupled With Nucleosomes. B)Quantitative/Semi-Quantitative Kit, Having 6 Calibrators And 2 Controls (One Negative And One Positive Control) C) Kit Contains All Calibrators, Controls, Sample Diluents, Was Buffer And Conjugate. D)All Calibrators, Controls, Sample Diluents And Conjugate Should Be In Liquid Form And Ready To Use. E) Relative Sensitivity And Specificity Equal Or More Than 90% F)Broad Measuring Range Of Up To 200U/Ml G) For Ivd Use. H)Pack Size-96Wells/Tests Per Pack. I) Expiry 6 To 8 Months Or More. , Anti Ccp Elisa Kit: A)Elisa Kits (96Wells Coated With Cyclic Citruliinated Peptide) For Quantitative/Semi-Quantitative Determination Of High Sensitive Lgg Class Of Antibodies Against Anti Ccp, With Positive And Negative Controls Clia Complexity-High, Disease Area Application-Rheumatoid Arthritis, Antigen Source-Synthetic Peptide, Ivd-In Vitro Diagnostic Use/Ce Marked, 3Rd Generation. B)Ready To Use Calibrators Must Be Provided Along With The Kit C) Sample: Serum Or Plasma. D) The Reagent Pack Must Have Expiry Of Minimum 06-08 Months At The Time Of Supply. , Anca Ethanol Fixed Ifa Kit:- Anti-Neutrophil Cytoplasmic Antibodies Detection Kit A)Kit For Detection Of Anti-Neutrophil Cytoplasmic Antibodies In Human Serum By Indirect Immune-Fluorescent Test System Utilizing Ethanol-Fixed Human Neutrophil Substrate Slides. B)Kit Should Contain Ethanol-Fixed Human Neutrophil Substrate On Glass Slide. C) Kit Should Contain Goat Anti-Human Igg Conjugate, Fluoresce In (Fitc) Labelled In Buffer. D) Kit Should Contain Ready To Use Positive Controls For Both Cytoplasmic And Perinuclear Patterns As Well As System Negative Control. E)Same Buffer Should Be Useable For Sample Dilution And Washing Purpose. F)Should Come With All Buffers And Accessories Like Mounting Media And Coverslips. G)The Reagents To Be Supplied Must Have Expiry Of Minimum 06-08 Months. H) Pack Size: 10X6 Well I)The Item Must Be Ivd Approved , Anca Formalin Fixed Ifa Kit:- Anti-Neutrophil Cytoplasmic Antibodies Detecting Kit A)Kit For Detection Of Anti-Neutrophil Cytoplasmic Antibodies In Human Serum By Indirect Immune-Fluorescent Test System Utilizing Formalin-Fixed Human Neutrophil Substrate Slides. B)Kit Should Contain Formalin-Fixed Human Neutrophil Substrate On Glass Slide. C) Kit Should Contain Affinity Purified Goat Anti-Human Igg Conjugate Labelled With Fluorescein (Fitc). D) Kit Should Contain Pre-Diluted Ready To Use Positive Controls For Perinuclear Patterns And Ana Homogeneous Patter As Well As System Negative Control. E)Same Buffer Should Be Useable For Sample Dilution And Washing Purpose. F)Should Come With All Buffers And Accessories Like Mounting Media And Coverslips. G)The Reagents To Be Supplied Must Have Expiry Of Minimum 06-08 Months. H) Pack Size: 10X6 Well I)The Item Must Be Ivd Approved , Mpo Elisa Kit:- Kit For Quantitative /Semi-Quantitativemeasurement Of Specific Igg Autoantibodies Against Myeloperoxidase A)Polystyrene Micro-Well Elisa, Plate Coated With Myeloperoxidase Antigen. B)Kit Should Be Quantitative /Semi-Quantitative Having Calibrators And Controls (One Negative And One Positive Control). C) It Should Contain All Calibrators, Controls, Sample Diluent, Wash Buffer And Conjugate Inside The Kit. D) All Calibrators, Controls, Sample Diluent And Conjugate Should Be In Liquid Form And Ready To Use. E)Relative Sensitivity And Specificity Should Be Equal Or More Than 90%. F)Broad Measuring Range Of Up To 100 U/Ml. G)The Reagents To Be Supplied Must Have Expiry Of Minimum 06-08 Months. H) Pack Size: 1X96 Well I)The Item Must Be Ivd Approved , Pr3 Igg Elisa Kit:- Kit For Quantitative /Semi-Quantitativemeasurement Of Specific Igg Autoantibodies Against Proteinase 3 A)Polystyrene Micro-Well Elisa Plate Coated With Pr3 Antigen. B)Kit Should Be Quantitative /Semi-Quantitative Having 5 Calibrator And 2 Controls (One Negative And One Positive Control). C) It Should Contain All Calibrators, Controls, Sample Diluent, Wash Buffer And Conjugate Inside The Kit. D) All Calibrators, Controls, Sample Diluent And Conjugate Should Be In Liquid Form And Ready To Use. E)Broad Measuring Range Of Up To 100U/Ml. F)Relative Sensitivity And Specificity Should Be More Than 90%. G)The Reagents To Be Supplied Must Have Expiry Of Minimum 06-08 Months. H) Pack Size: 1X96 Well I)The Item Must Be Ivd Approved , Gbm Elisa Kit:- Kit For Quantitative /Semi-Quantitativemeasurement Of Glomerular Basement Membrane Igg Antibodies A. Polystyrene Micro-Well Elisa Plate Coated With A Purified Glomerular Basement Membrane Antigen. B.Kit Should Contain Ready To Use Negative Control, Low Positive Control And High Positive Control And Sample Diluent. C. Kit Should Contain Goat Anti-Human Igg Conjugate Labelled With Hs Hrp. D.Kit Should Be Quantitative/Semi-Quantitative E. Should Have Relative Specificity And Sensitivity Of More Than 90%. F. Strong Precision And Reproducibility With Cv% Less Than 10%. G. Product Is For In Vitro Diagnostic Purpose. H.The Reagents To Be Supplied Must Have Expiry Of Minimum 06-08 Months. I.Pack Size: 1X96 Well J.The Item Must Be Ivd Approved

Key Value

Document Fees
Refer document
EMD
INR 200000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Two year Rate contract for supply of Reagents with its calibrator and control kits for Department of Biochemistry All India Institute of Medical Sciences, Raipur
Sl. No. Item Description
1Consumables & Reagents
2ANA Hep2- (IFT) - Anti Nuclear Antibodies screening kit by Immunoflurescent a)Kit for detection of anti-nuclear antibodies in human serum by indirect immune-fluorescent test system utilizing human epithelial cell substrate slides. b)Kit should contain HEp2 (human epithelial cell) substrate slides: 12 wells/slide with desiccant. c)Kit should contain goat anti-human IgG conjugate, fluorescein (FITC) labeled in buffer containing Evans blue. d) Kit should contain ready to use positive control (preferably homogenous pattern) as well as system negative control. e)Same buffer should be useable for sample dilution and washing purpose. f)Should come with all buffers and accessories like mounting media and cover-slips. g)Pack size-20x12wells (20glass slides of 12wells each) per pack / maximum pack size available. h) For IVD use. i)The reagents to be supplied must have expiry of minimum 06-08 months.
3ANA Profile 3 Plus (ANA Blot) kit Specifications: a)The test kit should provide a qualitative in vitro assay for human autoantibodies of the IgG class to at least 16 different antigens: nRNP, Sm, SS-A (native), Ro-52, SS-B, Scl-70, PM-Scl, Jo-1,CENP B, PCNA, dsDNA, nucleosomes, histones, ribosomal P-protein, AMA M2 and DFS70 inserum or plasma helpful for differential diagnosis of systemic rheumatic diseases. b)It should offer a multiplex approach for the determination of these antibodies in a single reaction. c)The antigens to be placed at defined positions on membrane strip. d) All different form of U1SnRNP (Rnp A, Rnp B, Rnp C) should be coated in the strip. e)All the conjugate reagents in the kit should be ready to use. f)The wash buffer in the kit should be ready to use. g)Interpretation software should give disease interpretation as well. h)Software should be user friendly. i) Software should have the function to export the results. j) Interpretation software should support any kind of flatbed/printer scanner. k)The result should be in intensity (%) index value format provided with range. l) For IVD use. m) Pack size-minimum pack size must be quoted for price calculation. n) Expiry of 6 to 8 months or more. ANA Profile 3 Plus (ANA Blot) kit Specifications: a)The test kit should provide a qualitative in vitro assay for human autoantibodies of the IgG class to at least 16 different antigens: nRNP, Sm, SS-A (native), Ro-52, SS-B, Scl-70, PM-Scl, Jo-1,CENP B, PCNA, dsDNA, nucleosomes, histones, ribosomal P-protein, AMA M2 and DFS70 inserum or plasma helpful for differential diagnosis of systemic rheumatic diseases. b)It should offer a multiplex approach for the determination of these antibodies in a single reaction. c)The antigens to be placed at defined positions on membrane strip. d) All different form of U1SnRNP (Rnp A, Rnp B, Rnp C) should be coated in the strip. e)All the conjugate reagents in the kit should be ready to use. f)The wash buffer in the kit should be ready to use. g)Interpretation software should give disease interpretation as well. h)Software should be user friendly. i) Software should have the function to export the results. j) Interpretation software should support any kind of flatbed/printer scanner. k)The result should be in intensity (%) index value format provided with range. l) For IVD use. m) Pack size-minimum pack size must be quoted for price calculation. n) Expiry of 6 to 8 months or more.
4dsDNA (Quantitative/semi-quantitative) kit Specifications: a) Polystyrene micro-well ELISA plate coated with calf thymus dsDNA coupled with nucleosomes. b)Quantitative/semi-quantitative kit, having 6 calibrators and 2 controls (one negative and one positive control) c) Kit contains all calibrators, controls, sample diluents, was buffer and conjugate. d)All calibrators, controls, sample diluents and conjugate should be in liquid form and ready to use. e) Relative sensitivity and specificity equal or more than 90% f)Broad measuring range of up to 200U/ml g) For IVD use. h)Pack size-96wells/tests per pack. i) Expiry 6 to 8 months or more.
5Anti CCP Elisa Kit: a)Elisa Kits (96wells coated with cyclic citruliinated peptide) for quantitative/semi-quantitative determination of high sensitive lgG class of antibodies against anti CCP, with positive and negative controls CLIA complexity-high, Disease Area Application-Rheumatoid Arthritis, Antigen source-Synthetic peptide, IVD-IN vitro Diagnostic use/CE marked, 3rd generation. b)Ready to use calibrators must be provided along with the kit c) Sample: Serum or Plasma. d) The reagent pack must have expiry of minimum 06-08 months at the time of supply.
6ANCA Ethanol Fixed IFA Kit:- Anti-neutrophil cytoplasmic antibodies detection kit a)Kit for detection of anti-neutrophil cytoplasmic antibodies in human serum by indirect immune-fluorescent test system utilizing ethanol-fixed human neutrophil substrate slides. b)Kit should contain ethanol-fixed human neutrophil substrate on glass slide. c) Kit should contain goat anti-human IgG conjugate, fluoresce in (FITC) labelled in buffer. d) Kit should contain ready to use positive controls for both cytoplasmic and perinuclear patterns as well as system negative control. e)Same buffer should be useable for sample dilution and washing purpose. f)Should come with all buffers and accessories like mounting media and coverslips. g)The reagents to be supplied must have expiry of minimum 06-08 months. h) Pack size: 10x6 well i)The item must be IVD approved
7ANCA Formalin Fixed IFA Kit:- Anti-neutrophil cytoplasmic antibodies detecting kit a)Kit for detection of anti-neutrophil cytoplasmic antibodies in human serum by indirect immune-fluorescent test system utilizing formalin-fixed human neutrophil substrate slides. b)Kit should contain formalin-fixed human neutrophil substrate on glass slide. c) Kit should contain affinity purified goat anti-human IgG conjugate labelled with fluorescein (FITC). d) Kit should contain pre-diluted ready to use positive controls for perinuclear patterns and ANA Homogeneous patter as well as system negative control. e)Same buffer should be useable for sample dilution and washing purpose. f)Should come with all buffers and accessories like mounting media and coverslips. g)The reagents to be supplied must have expiry of minimum 06-08 months. h) Pack size: 10x6 well i)The item must be IVD approved
8MPO Elisa Kit:- Kit for quantitative /semi-quantitativemeasurement of specific IgG autoantibodies against myeloperoxidase a)Polystyrene micro-well ELISA, plate coated with Myeloperoxidase antigen. b)Kit should be quantitative /semi-quantitative having calibrators and controls (one negative and one positive control). c) It should contain all calibrators, controls, sample diluent, wash buffer and conjugate inside the kit. d) All calibrators, controls, sample diluent and conjugate should be in liquid form and ready to use. e)Relative sensitivity and specificity should be equal or more than 90%. f)Broad measuring range of up to 100 U/ml. g)The reagents to be supplied must have expiry of minimum 06-08 months. h) Pack size: 1x96 well i)The item must be IVD approved
9PR3 IgG Elisa Kit:- Kit for quantitative /semi-quantitativemeasurement of specific IgG autoantibodies against proteinase 3 a)Polystyrene micro-well ELISA plate coated with PR3 antigen. b)Kit should be quantitative /semi-quantitative having 5 calibrator and 2 controls (one negative and one positive control). c) It should contain all calibrators, controls, sample diluent, wash buffer and conjugate inside the kit. d) All calibrators, controls, sample diluent and conjugate should be in liquid form and ready to use. e)Broad measuring range of up to 100U/ml. f)Relative sensitivity and specificity should be more than 90%. g)The reagents to be supplied must have expiry of minimum 06-08 months. h) Pack size: 1x96 well i)The item must be IVD approved
10GBM Elisa Kit:- Kit for quantitative /semi-quantitativemeasurement of glomerular basement membrane IgG antibodies a. Polystyrene micro-well ELISA plate coated with a purified glomerular basement membrane antigen. b.Kit should contain ready to use negative control, low positive control and high positive control and sample diluent. c. Kit should contain goat anti-human IgG conjugate labelled with HS HRP. d.Kit should be quantitative/semi-quantitative e. Should have relative specificity and sensitivity of more than 90%. f. Strong precision and reproducibility with CV% less than 10%. g. Product is for in vitro diagnostic purpose. h.The reagents to be supplied must have expiry of minimum 06-08 months. i.Pack size: 1x96 well j.The item must be IVD approved