Tender For Special Repair To Smqs And Certain Garages At Af Station Palam Under Ge Af Gurgaon No.1; 1 Schedule Of Work ( B / R Portion ) 2 Taking Down Cement Plaster From Wall And Ceiling Of Any Description From Brick / Concrete Surfaces Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc., And Removing Same From The Site ( S ) , Complete All As Specified And As Directed. ( Note :- Rate Included For Four Storey Building Including Scaffolding And All Safety Measures ) 3 M&L For 15 Mm Thick Cement Plaster On Fair Faces In Cm 1:4 On Brick / Concrete Surfaces On Wall, Mixed With Water Proofing Compound, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. Note :- Water Proofing Compound Shall Be Measured & Paid Separately Under Respective Item Of Schedule As Supply Only Rate. 4 M&L For 15 Mm Thick Cement Plaster Other Than Fair Faces In Two Layer ( Under Layer 10 Mm And Upper Layer 5 Mm Thick ) In Cm 1: 6 On Brick / Concrete Surfaces On Wall, Upper Layer Of 5 Mm Thick Mixed With Water Proofing Compound, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engr-In-Charge. Note :- Water Proofing Compound Shall Be Measured & Paid Separately Under Respective Item Of Schedule As Supply Only Rate. 5 M&L For 5Mm Thick Rendering In Cm 1:3 On Concrete / Gunniting Surface As In Ceiling Finished Even And Smooth Without Using Extra Complete All As Specified And Directed By Engr-In-Charge 6 M&L For Washed Stone Grit Plaster On Exterior Walls In Two Layers, Under Layer 12Mm Cement Plaster 1:4 ( 1 Cement: 4 Coarse Sand Mixed With Liquid Wpc ) Furrowing The Under Layer With Scratching Tool, Applying Cement Slurry On The Under Layer @ 3Kg Of Cement Per Square Metre, Top Layer 15Mm Cement Plaster 1:1 / 2:2 ( 1 White Cement: 1 / 2 Coarse Sand: 2 Stone Chipping 6Mm T0 10Mm Nominal Size ) In Panels With Groove All Around As Per Approved Pattern Including Scrubbing And Washing, The Top Layer With Brushes And Water To Expose The Stone Chippings Complete All As Specified ( Payment For Providing Grooves Shall Be Made Separately ) 7 M&L For Forming Groove Of Uniform Size 15Mm Wide And 15Mm Deep In The Top Layer Of Washed Stone Grit Plaster As Per Approved Pattern Using Aluminium Channel, Nailed To The Under Layer Including Removal Of Wooden Battens, Repair To The Edges Of Panels And Finishing The Groove Complete As Specified And Directed By Engineer-In-Charge. 8 M&L For Prepration Of New Plaster Wall Surfaces And Applying Two Coat Of Exterior Acrylic Emulsion Paint ( 100% Acrylic ) Of Approved Colour And Shade Over A Coat Of Primer And Over 1 To 2 Mm Thick Birla Putty Punning , Including Necessary Scaffolding Upto 4Th Floor Complete All As Specified And As Directed By Engineer-In-Charge. 9 M&L For Prepration Of New Plaster Wall Surfaces And Applying Two Coat Of Distemper Oil Emulsion By Auto Roller Over A Coat Of Primer Over 2 To 3 Mm Thick Birla Putty Punning Including Finishing Bysanding Machine And Auto Roller New Surface Complete All As Specified Or As Directed By Engineer-In-Charge.Make: Asian Paint ( Tractor ) / Berger Paints ( Bison Super ) 10 M&L For Preparation Of New Plastered Surfaces On Ceiling Surface And Applying Three Coats Of White Wash Complete And All As Specified And As Directed 11 M&L For Complete Removal Of Old Surfaces On Wall Surfcesand Applying Two Coat Of Exterior Acrylic Emulsion Paint ( 100% Acrylic ) Of Approved Colour And Shade Over A Coat Of Primer And Over 1 To 2 Mm Thick Birla Putty Punning Including Preparation Of Old Plastered Surface And Scaffolding Upto 4Th Floor Complete All As Specified And As Directed By Engineer-In-Charge. 12 M&L For Complete Removal Of Old Plastered Surfaces Of Walland Applying Two Coat Of Distemper Oil Emulsion By Auto Roller Over A Coat Of Wall Primer Over 2 To 3 Mm Thick Cement Based Wall Puttycomplete All As Specified Or As Directed By Engineer-In-Charge. 13 M&L For Complete Removal Of Old Surfaces On Ceiling And Applying Three Coats Of White Wash Complete And All As Specified And As Directed 14 Demolition Of Brick Work Or Stone / Boulders Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars Etac But Excluding Ashlars Facings, Dressed Stone Work And Precast Concrete Articles Complete All As Specified And Directed By Engineer-In-Charge. 15 M&L Forbrick Work With Sub Class B Bricks Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cement Mortar 1:4 Complete All As Specified And Directed By Engr-In-Charge 16 S&F Galvanised Steel Water Tubing 15Mm Bore ( Dia ) , ‘Medium Grade’ With All Fittings, Fixed To Concealed Or Onwalls, Ceiling Or Laid In Floors Or Any Other Situ-Ation Including Taking Up Down Unserviceable Steel Water Tubing With Fittings And Connections, Etc. Complete All As Specified And As Directed. 17 S&F Galvanised Steel Water Tubing 20Mm Bore ( Dia ) , ‘Medium Grade’ With All Fittings, Fixed To Concealed Or Onwalls, Ceiling Or Laid In Floors Or Any Other Situ-Ation Including Taking Up Or Down Unserviceable Steel Water Tubing With Fittings And Connections, Etc. Complete All As Specified And As Directed. 18 S&F In Repairs, 20 Mm Bore Gun Metalgate / Globe Half Turn Valves With Iron Wheel / Lever Fixed-In-Repairs Complete All Asspecified And Directed Byengineer In Charge. 19 S&F Stop Valves, Fancy Type 15 Mm Bore ( Dia ) Cast Copper Alloy, Plated, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or Forunions And Fixed-In-Repairs Complete All As Specified And As Directed. 20 S&F Bib Taps 15 Mm Bore ( Dia ) Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Andfixed-In-Repairs, Complete All As Specified And As Directed. 21 S&Ftwo Way Brass Cp Bib Taps 15Mm Bore Cast Copper Alloy With Crutch Or Butterfly Screwed Down Screwed For Iron Pipe Or For Brass Ferrul And Fixed In Repair Complete All As Spd And As Directed 22 S&F In Repair Brass Cp Towel Rail 20 Mm Dia, Including Taking Down Of Old Towel Rail Of Any Size, Complete As All Specified And Directed. 23 S&F Brass Cp Health Faucet, As Approved, Including Taking Down Unserviceable Health Fosset Of Any Description, Complete As All Specified And Directed. Make :- Cera, Johnsen, Jaugar, Marc. 24 S&F Stainlesssteel Wire Cloth, 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4 Mm And Fixed With Tinned Tacks Of Mild Steel Wire Stapes, Etc, Complete All As Specified And As Directed. 25 S&F Sheet Glass, 4.0Mm Thick Ordinary, Glazing As In Window Frames Fixed With Wooden Oil Putty / Rubber Beads, Not Exc. 0.50 Sqm In Each Pane And Fixed In Repairs, Complete All As Specified And As Directed. 26 S&F In Repair, 500 Ltr Capacity Rotational Moulded Polyethylene Water Storage Tanks ( Cylindrical Vertical With Closed Top ) Three Layered, Isi Marked, Hoisted And Fixed In Position Including Tank Neeples Of Required Size And 20 Mm Bore Dia Pipe Ball Brass Valve High Pressure With Plolythelene Float And Flynutcomplete All As Specified In Ssr Part I Complete All As Specified And As Directed. 27 S&F In Repair, 1000 Ltr Capacity Rotational Moulded Polyethylene Water Storage Tanks ( Cylindrical Vertical With Closed Top ) Three Layered, Isi Marked, Hoisted And Fixed In Position Including Tank Neeples Of Required Size And 20 Mm Bore Dia Of Pipe Ball Brass Valve High Pressure With Plolythelene Float And Flynutcomplete All As Specified In Ssr Part I Complete All As Specified And As Directed. 28 Demolition Of Cement Concrete ( Unreinforced ) In Ground Floor And Paving Not Exceeding 15 Cm Thickness ( Below Or Above Ground Level ) Complete All As Specified And Directed By Engr-In-Charge. 29 M&L 75Mm Thick Plain Cement Concrete 1:3:6, Type C-2 Using 40Mm Graded Aggregateas In Plinth Protection And Court Yard , Finished Even And Smooth Without Using Extra Cement In Panel And Providing Groves Complete All As Specified And Directed By Engr In Charge 30 M&L For Providing 75 Mm Thick Cement Concrete Type B-2, 1:2:4 Using 40 Mm Graded Aggregate Laid In Path And Hardstanding Complete All As Specified And Directed By Engr-In-Charge. 31 M&L Chequered Cement Concrete Tiles 300X300x25mm Thick, Set Jointed And Pointed In Neat Cement Slurry In Floors With White Cement And Pigments In Any Colour , Over And Including Cement Screed Bed 15Mm Thick Cement Mortar 1:4 All As Specified And As Directed 32 Dismantling Floor Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) & Remove Rubbish From Mod Land, Complete All As Specified And Directed By Engr-In-Charge 33 M & L For Non-Skid Ceremic Colour Tile Size Of7 To 8 Mm Thick ( Square / Rectungular ) Area Exc. 0.06 Sqm But Not Exc 0.11 Sqm Laid In Floors Setting And Jointed With Neat Cememy Slurry Over And Including 15 Mm Thick Screed Bed In Cement Mortar 1:6, And Pointed With Coloured Cement To Mathc With Surfaces Of Tiles, Complete All As Specified And Directed By Engr-In-Charge 34 M&L Non Skid Coloured Ceramic Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding0.11 Sqm But Not Exceeding 0.18 Sqmin Floors Etc , Set And Jointed In Neat Cement Slurry Andpointed In White / Coloured Cement To Match Over And Including15 Mm Thick Screed Bed In Cement Mortarin ( 1:6 ) Completeall As Specified And As Directed By Engineer-In-Charge. 35 M&L For Glazed Ceramic Coloured Tiles In Vertical Surface 450 X 350 X 7 To 8 Mmthick Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match And Including 10Mm Thick Screed Bed In Cement Mortar 1:4 Laid And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Shade Of The Tiles, Complete All As Specified And As Directed. 36 Dismantling Of Old Existing Ci / Concrete Pipes Of Any Description, Jointed In Cement Mortarup To 100 Mm Dia And Removing From Site Complete All As Specified And As Directed. 37 S&F In Repair Pvc ( Swr ) Pipes 110Mm In Bore ( Dia ) , Single Socketed, In Any Length With Rubber Ring Joints Fixed To Walls / Floors, Etc, Including Taking Down / Up Unserviceable Pipe, Complete All As Specified And As Directed. 38 All As Per Item No 36 Above But 75 Mm Bore -Ditto-. 39 Supply Only Liquidwater Proofing Compound Complete All As Specified And Directed. 40 S&F Pvc ( Swr ) Bend Suitable For Pvc ( Swr ) Pipes 75Mm In Bore ( Dia ) With Access Door, Jointing With Solvent Cement And Fixed-In-Repairs, Complete All As Specified And As Directed. 41 S&F 75 Mm Dia Pvc ( Swr ) Tee With Access Door Suitable For Pvc ( Swr ) Pipes 75Mm In Bore ( Dia ) , Jointing With Solvent Cement And Fixed-In-Repairs, Complete All As Specified And As Directed. 42 S&F 75Mm Dia Sand Cast Iron Soil, Waste And Vent Pipes In Any Length With Or Without Ears With Cement Joints Fixed To Walls Complete All As Specified And Directed. 43 S&F 100Mm Dia Sand Cast Iron Soil, Waste And Vent Pipes In Any Length With Or Without Ears With Cement Joints Fixed To Walls With Oval Access Door Complete All As Specified And Directed. 44 S&F In Repair 75Mm Dia Ci Bends With Oval Access Door, Diminishing Pieces Or Tapers Complete All As Specified And Directed. 45 S&F In Repair 100Mm Dia Ci Bends, Diminishing Pieces Or Tapers Complete All As Specified And Directed. 46 S&F In Repair 75Mm Dia Ci Branch Pieces, Single ( Equal Or Unequal ) Ordinary Or Inverted ( Spigot Or Socket Type ) Or With Paralled Branches With Ovel Access Door Complete All As Specified And Directed. 47 S&F In Repair 100 Mm Dia Ci Branch Pieces, Single ( Equal Or Unequal ) Ordinary Or Inverted ( Spigot Or Socket Type ) Or With Paralled Branches With Ovel Access Door Complete All As Specified And Directed. 48 S&F In Repair Stack Clamp Made Out Of Gi Angle And 10Mm Dia U Bolt And Nut With Washer For 75 And 100 Mm Dia Pipe Complete All As Specified And Directed. 49 Demolition Of Reinforced Cement Concrete Placed In Any Position Including Cut Of Bars As Required, Complete All As Specified And Directed. 50 M&L For Reinforced Cement Concrete ( Nominal Mix ) 1:2:4 Type B-1 Using 20 Mm Graded Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs Shelves , Chhajja And The Like Etc Including Necessary Formwork Complete All As Spd And Directed 51 M&L For Ms Tmt Bars 10Mm Dia And Over, Cut To Length Bent To Shape Required Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Incl Ms Wire ( Annealed ) Not Less Than 0.9 Mm Dia Or Securing With Clips Complete All As Specified And Directed. 52 Re-Baring By Drilling Holes And Fixing Nozzle If Required In Existing Concrete / Brick Work As In Column, Beams, Slabs And Foundation Etc In Any Position And Any Description Size Of Hole 14Mm, 16Mm & 22Mm Suitable For Dowels Of Size 10Mm, 12Mm & 16Mm Respectively ( Minimum Depth 140Mm For 10Mm & 12 Mm Dia Bars And 180Mm For 16Mm Dia Bar, Cleaning The Surface Properly With Blow Out Pump & Round Brushes And Fixing Of Dowel Bars With Epoxy Resin ( Resin+Hardner ) .Make: Sika, Fosroc Or Concressive 1450 Of Basf Complete All As Specified And Directed By Engr-In-Charge. Note:- ( I ) Adequate Lap Length Shall Be Provided As Per Is-456-2000. ( Ii ) Reinforced Tmt Bars Where Incorporated In Work Will Be Paid Under The Relvent Items. ( Iii ) The Work Shall Be Carried Out Upto Four Storied Building With Scaffolding And In Patches As Directed By Engr-In-Charg E. ( Iv ) Rate For Scaffolding And Formwork Wherever Required And As Directed To Be Included In Quoted Rate. ( V ) The Works Will Be Executed In Different Buildings And At Scattered Locations. 53 Removal Of Demolish Material Debris / Malwa / Surplus Soil To A Distance Exc 10 Km But N Exc 15.00 Km Out Side Md Land And Depositing Where As Directed, Complete All As Specified And Directed By Engr-In-Charge. 54 M&L For Gunniting To Rcc Works In Column, Beams, Slabs, Chajja, Facia, Landing, Balconies And Similar Wks Etc By Removing / Dismantling Of Rcc ( Loose Concrete ) Including Plasterand Cutting Of Steel Barincluding Cleaning Of Surfaces With Wire Brushes And Applying Epoxy, Paint Anti Corrosive Coating Of Minimum 40-50 Microns Thick With Sikatop Armatec 108 Or Colusal Vl Of Mc Bauchemie To Rusted Steel Reinforcement After Removing Cleaning All Rust And Supply And Fixing With Sufficient Fasteners / Concrete Nails / Welding At Regular Intervals Welded Steel Wire Mesh 75Mm X75mm With 4Mm Dia Steel Wire As Faces / Drops And Applying Epoxy Based Or Other Equivalent Suitable Bonding Against Treatment To Be Carried Out On Old Concrete Surface With Sikadur 32 Of Sikka.Nito Bond Ep Of Fosroc Or Equivalent ( As Per Manufacturers Instruction ) To Bond Old And New Concrete Mixing @ 2% By Weight Of Cement Polycrete And Providing Gunniting With A Minimum Pressure Of 2 To 2.5 Kg Sqcm With Varying Thickness From 25Mm To 100Mm As Per Requirement At Site Gunniting In Cement Mortar ( 1:2 ) ( One Part Of Cement And Two Part Of Ghaghar Sand ) And Plastering In Cm 1:4 To A Uniform Surface, Wherever Required At Any Height, Location And Position Complete All As Specified And Directed By Engineer-In-Charge. Note:- ( I ) After Placing The Additional Reinforcement All Concrete Surface Shall Be Thoroughly Scrubbing With. ( Ii ) Additional Reinforced Tmt Barswere Incorporated In Work However Min 20Mm Thick Cement Plaster In 1:4 And Necessary Connected Wks Related To Gunniting To Be Included In Quoted Rate. ( Iii ) Work To Be Carried Out As In Patches As Directed By Engr-In-Charge. ( Iv ) Rate For Steel Scaffolding And Formwork Wherever Required And As Directed To Be Included In Quoted Rate. ( V ) All Demolished Material Removed From Mod Land Completely. ( Vi ) The Works Will Be Executed In Different Buildings And At Scattered Locations. 55 Dismantling Ofexisting Roof Tile / Treatment Any Size / Description All As Specified And Directed By Engr-In Charge. 56 Cleaningtop Surfaces By Brooming, Wire Brushing, Removing Grass, Raking Out Joints To Receiveplaster And Removing Debris, Grass Etc Outside The Defence Land Completeall As Specified And Directed By Engineer-In-Charge.Note :-1. Plaster Shall Be Measuredandseparately Under Appropriate Item Of Sch ‘A’.2.Rate Of This Item Is Inclusive Of Diconnectfitment At Water Tank Orsolar Heater Etc And Refixing In The Same Position After Compeleting Of Roof Treatment. 57 M&L Water Proofing Treatment On Roof And Vertical Surface Consisting As Under:- ( A ) Applying Evenly A Coat Of Bituminous Primer Conforming To Is-3384:1986 @ 0.30 Litre / Sqm Including Preparation Of Roof Surfaces ( B ) Applying Evenly A Tack Coat Of Industrial Bitumen 85 / 25 @ 1.2 Kg / Sqm On Plaster Surface All As Specified. ( C ) A Layer Of 3Mm Thick App Polymeric Membrane Of Weight Not Less Than 3.60 Kg / Sqm, Reinforced With Polyester Non-Woven Fabric ( Weight Not Less Than 160Gm / Sqm ) , Duly Sealed At Over Laps & Joints With End Laps Of The 10Cm And Side Over Laps Of 7.5Cm By Flame ( By Torch Application ) All As Per Manufacturer’S Instructions, Complete All As Specified And Directed. 58 Pre Construction Anti Termite Treatment For Filling Under Floor / Plinth Protection By Using Chlropyriphos 20% Ec Emulsion @5.00Ltr / Sqm Complete All As Specified And As Directed. 59 Pre Construction Anti Termite Treatment Along The Outer Periphery Of Building By Using Chlropyriphos 20% Ec Emulsion @2.25 0Ltr / Rm Complete All As Specified And As Directed. 60 M & L For 100Mm Thick Pcc 1:4:8 Type D-2 Using 40 Mm Graded Stone Aggregate As In Sub Base Of Floor, Path And Hard Standing Complete All As Specified And As Directed. 61 M&L Machine Cut Kota Stone Slab Flooring 20-25Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishinglaid Over 15Mm Thick Screed Bedding Layer In Cm 1:4 For Laying In Floor Etc Complete All As Specified And As Directed By The Engr-In-Charge 62 M&L Machine Cut Kota Stone 15-20Mm Thick As In Skirting Over 10Mm Thick Rendering In Cm 1:4 Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing And Finishing With Mirror Polishing Complete All As Specified And As Directed By The Engr-In-Charge 63 M&L For 15Mm Thick Rendering On Brick Or Concrete Surfaces In Internal Surfaces In Cement Mortar 1:6, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed By Engineer-In-Charge. 64 M&L For Preparation Of Newely Plastered Wall Surface And Applying Three Coats Of White Wash Complete And All As Specified And As Directed 65 M&L For Pcc 1:2:4 Type B-0 ( Using 12.5Mm Graded Stone Aggregate ) As In Coping, Benching, Bed Block, Window Cills Etc Complete All As Specified And As Directed By Engr-In-Charge 66 Dismantling Wought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided Forcomplete All As Specified And As Directed By Engr-In-Charge 67 S & F Steel Rolling Shutters ( Thickness Of Laths In 1.25Mm ) , Without Ball Bearing, As Specified Including Top Cover, Anchoring Rod, Hasps And Staple And One Shop Coat Of Primer :Erected In Position As Indicated Complete But Gear Operated Type With Bevel Gear Box And Cranck Handle Complete All As Specified And As Directed By Engr-In-Charge 68 S&F Safety Lever Locks Mild Steel With 4 Lever For Rolling Shutters Complete All As Specified And As Directed. 69 S&F Ball Bearing For Rolling Shutters Complete All As Specified And As Directed. 70 M&L Preparation New Or Previously Untreated Steel Surface Of Any Description, Over 10 Cm In Width Or Girth Applying Two Coat Synthetic Enamelpaint Over One Coat Of Red Oxide Zinc Chrome Primer Over Complete All As Specified And Directed By Engr-In-Charge. 71 M&L For Complete Removal Of Existing Old Treatment By Scraping Down With Steel Brush / Steel Patty Preparing Old Plastered Surface Of Walls And Applying Two Coats Of White Wash Complete All As Specified And Directed. 72 Dismantling Of Asbestos Cement Sheet Corrugated Or Semicorrugated Etc In Roofcovering Etc.Complete All As Specified And Directed. 73 S&F 0.50 Mm Thickpre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering Fixed With Self Tapping Screwscomplete All As Specified And Directed. 74 S&F Ms Framed Work As In Doors Or Gates Of Angle Or Other Section As Chowkhat., Tie Bar, Hold Fast, Guard Bars, Chajja Etccomplete Cooler Stand Etc, Drilled For Fixingcomplete Fe-410Complete All As Specified And Directed. 75 M&L For Complete Removal Of Existing Old Treatment By Scraping Down With Steel Brush / Steel Patty Preparing Old Plastered Surface Of Ceiling And Applying Two Coats Of White Washcomplete All As Specified And Directed. 76 M&L For 15 Mm Thick Cement Plasteringin Cm 1:4 On Brick / Concrete Surfaces Of Roof And Parapet, Mixed With Water Proofing Compound, Finished Even And Smooth Without Using Extra Cement ( Including 4 Story Building ) Complete All As Specified And As Directed By Engineer-In-Charge. Note :- Water Proofing Compound Shall Be Measured & Paid Separately. 77 E / M Portion 78 Taking Down Copper / Aluminium Point Wiring ( Light Points ) Complete, Including Fixtures And Fittings Such As Switches, Ceiling Roses, Pendents, Regulators, Sockets, Light Fittings Etc. Removing Materials To Store For Keeping In Safe Custody Or For Taking Credit ( Credit For The Above Items Should Be Made As Per Conditions Seperately ) And Making Good Disturbed Surfaces Of Walls. Floors, Etc. Complete All As Directed 79 Taking Down Carefully By Unscrewing From Theboards / Outlets Boxes Fittings And Fixturessuch As Switches, Sockets Ceiling, Rose, Lamp Holders, Tube Light Fittings, Regulators Etc And Making Good Of Disturbedsurfaces Complete All As Specified And As Directed. 80 Taking Down Ofexisting Old Unserviceable Submain Wiringcomplete All As Specified And As Directed. 81 Taking Down Ofexisting Old Unserviceable Mcbof Any Ratingcomplete All As Specified And As Directed. 82 Taking Down Ofexisting Old Unserviceable Vtpn Distribution Board With Mccb Of Any Type Complete All As Specified And As Directed. 83 Taking Down Of Led Tube Light / Ceilling Light / Round Light / Bulkhead Light Of Any Type And Capacity Complete All As Specified And As Directed. 84 Material & Labour For Concealed Point Wiring With Single Core Pvc Insulated And Unsheathed 1100 Volts Grade Cable With Multistranded Copper Conductor Of Size 1.5 Sqmm Nominal Area Drawn Through & Including Non Metallic Rigid Pvc Conduit ( Circular / Flat Pvc Conduit ) , Medium Duty Not Less Than 20 Mm Dia Concealed In Wall / Fixed On Wall / Ceiling With Gi Saddles , Gi Screws , Rawl Plugs With All Fittings Including Tees , Junction Boxes & Provision For Modular Box And Modular Cover Of Suitable Size For Mounting Modular Switches , Sockets & Regulators & Drawing Through Continuous Earth Wire Of Pvc Insulated Unsheathed 1100 Volts Grade Cable With Copper Conductor Solid Conductor Of Size 1.5 Sqmmcomplete All As Specified & Directed By Engineer -In-Charge.Note: Cost For Cutting Chases And Making Good To Match The Existing Surface Shall Be Deemed To Be Included In The Quoted Rate. 85 One Light Point Controlled By One Single Pole Switch & Socket. 86 One 3 Pin Sockets Outlet 5 Amps On The Same Board With Other Switches With Cable Of Size 1.5 Sqmm 87 One 3 Pin Sockets Outlet 5 Amps Independent With Cables 1.5Sqmm Size 88 All As Per Srl Item No. 83.01 Above Butsocket Outlet Independent But Below The Switch Board Of Light Points In The Same Vertical Plane, With Cables.2.5 Sq. Mm Size 89 Supply And Fixing Of Modular Switches 1 Way, 6 Amp 1 Module Complete All As Specified & Directed. 90 Supply And Fixingmodular Socket, 6A - 2 / 3 Pin Combined 2 Module, Complete All As Specified & Directed . 91 Supply And Fixing Of Modular Switches 1 Way, 16 Amp 1 Module Complete All As Specified & Directed . 92 Supply And Fixingmodular Socket 6A / 16A - 2 / 3 Pin Combined 2 Module, Ccomplete All As Specified And As Directed. 93 Supply And Fixing Led Lights Fitting 1X 16W, 220V, Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And As Directed. 94 S&F Submain Wiring Withunsheathed Multi-Stranded Fr Grade Copper Conductor Cable 1100 Volts Grade Drawn Through In And Including Pvc Rigid Conduit Medium Grade Of Not Less Than 20Mm Dia With Conduit Accessories And Concealed In Wall / Surface Of Ceiling For Two Runs Of 2.5 Sqmm Single Core Hr Grade And One Run Of 2.5 Sqmm Pvc Insulated Copper Conductor For Earth Continuity Wire Between Main Db To Sub Main Db Points Complete All As Specified And As Directed.Note :- Two Run Of Single Core Cable With One Run Of Earth Continuity Conductor And Pvc Conduit And Accessories Will Be Measured As One Length Including Cutting Chasing In Wall Complete.Note: Rates Are Deemed To Be Included For Chases Of Conduit And Sunking For Boxes Cutting And Making Holes In Wall / Floor For Passing In Or Through Conduit. 95 S&F Submain Wiring Withunsheathed Multi-Stranded Fr Grade Copper Conductor Cable 1100 Volts Grade Drawn Through In And Including Pvc Rigid Conduit Medium Grade Of Not Less Than 20Mm Dia With Conduit Accessories And Concealed In Wall / Surface Of Ceiling For Two Runs Of 1.5 Sqmm Single Core Hr Grade And One Run Of 1.5 Sqmm Pvc Insulated Copper Conductor For Earth Continuity Wire Between Main Db To Sub Main Db Points Complete All As Specified And As Directed.Note :- Two Run Of Single Core Cable With One Run Of Earth Continuity Conductor And Pvc Conduit And Accessories Will Be Measured As One Length Including Cutting Chasing In Wall Complete.Note: Rates Are Deemed To Be Included For Chases Of Conduit And Sunking For Boxes Cutting And Making Holes In Wall / Floor For Passing In Or Through Conduit. 96 S&Fgi Modular Gang Sunk-In Pressedterminal Boxes Of Required Size Not Less Than 1.2 Mm Thick Factory Made For Following Module Complete All Specified And Directed.Note: Flushing Of Module Box In Wall With Cement And Repairing The Wall As Before Is Deemed To Be Included In Quoted Rate. 97 Metal Flush Box 3 Module 98 Metal Flush Box6 Module 99 S&F White Cover Plate With Frame Of Following Module Complete All Specified And Directed. 100 White Cover Plate With Frame 3 Module 101 White Cover Plate With Frame 6 Module 102 Supply And Fix In Replacement Of Factory Made Epoxy Polyster Powder Coated Vtpn Distribution Boardtriple Pole Mcb4 Way 415V Fabricated From Minimum 1.6 Mm Thick Crca Sheet With Double Door ( Ip-43 Protection ) Fixed Flush To Wall And Standard Din Rail, Earth Bar And Cable Ties For Cable Management, Provision For 63 Amps Mccb As One Incommerand 12 Outgoings Single Pole Mcb With 2 Neutral Bar, 2 Earthbar, Fully Insulated Busbar Rated Capacity Above 63 Amp, Shrouded Neutral Bars And Cable Ties For Cable Management Complete All As Specified And Confirming To Iec 61439-3, Reversible Door Ip 43 & Ip 54 Complete All As Specified And Directed. Make: Legrand / Siemens / Schneider. Note: Cutting On Wall And Taking Out Old One And Then Flushing New Db And Making All The Connection As Before And Any Accessories Required To Fix The Db Including Making Good The Disturbed Surface Is Deemed To Be Included In Quoted Rate. 103 Supply & Fixing Mccb 63 Amps4 Pole, 415 V, Fixed Thermal & Fixed Magnetic Setting Electromechanical Type With Ics=75 % Of Icu , With Breaking Capacity 16 Ka Conforming To Is: 13947-Ii Complete All As Specified And As Directed. 104 S&F In Replacement Of Mcb Sp 6-32 Amps , 10 Ka 230 Volts , 50 Hz Complete All As Specified And As Directed By Engineer -In -Charge . 105 Supply , Laying , Testing And Commissioning In Replacement Of Xlpe Insulated And Pvc Sheathed , Galvanized Steel Strip Or Wire Armoured , Heavy Duty Electric Cable With Multi Stranded Aluminium Conductor, 1100 Volts Grade Of Size 16 Sqmm 4 Core Complete All As Specified & Directed By Engineer - In - Charge. 106 Note:- The Amount Of Rs 40308 / - Against Schedule Of Credit On Page No 145 Shall Be Deducted From The Total Amount Quoted Against Sch AWhile Deriving The Contract Sum For Acceptance

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 92000.0 /-
Tender Value
INR 46 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR TO SMQs AND CERTAIN GARAGES AT AF STATION PALAM UNDER GE (AF) GURGAON NO.1 .
Sl. No. Item Description
1Schedule of work (B/R Portion)
2Taking down Cement Plaster from wall and ceiling of any description from Brick/concrete surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the site(s), complete all as specified and as directed. (Note :- Rate included for four storey building including scaffolding and all safety measures)
3M&L for 15 mm thick cement plaster on fair faces in CM 1:4 on brick/concrete surfaces on wall, mixed with water proofing compound, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. Note :- Water proofing compound shall be measured & paid separately under respective item of schedule as "supply only" rate.
4M&L for 15 mm thick cement plaster other than fair faces in two layer (under layer 10 mm and upper layer 5 mm thick) in CM 1: 6 on brick/concrete surfaces on wall,upper layer of 5 mm thick mixed with water proofing compound, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge. Note :- Water proofing compound shall be measured & paid separately under respective item of schedule as "supply only" rate.
5M&L for 5mm thick rendering in CM 1:3 on concrete/gunniting surface as in ceiling finished even and smooth without using extra complete all as specified and directed by Engr-in-charge
6M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand mixed with Liquid WPC) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 white cement: 1/2 coarse sand: 2 stone chipping 6mm t0 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately)
7M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using Aluminium Channel, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as specified and directed by Engineer-in-charge.
8M&L for prepration of new plaster wall surfaces and applying two coat of exterior Acrylic emulsion paint (100% acrylic) of approved colour and shade over a coat of primer and over 1 to 2 mm thick birla putty punning , including necessary scaffolding upto 4th floor complete all as specified and as directed by Engineer-in-charge.
9M&L for prepration of new plaster wall surfaces and applying two coat of Distemper oil emulsion by Auto Roller over a coat of primer over 2 to 3 mm thick birla putty punning including finishing bySanding Machine and Auto Roller new surface complete all as specified or as directed by Engineer-in-charge.Make: Asian Paint (Tractor)/Berger paints (Bison super)
10M&L for preparation of new plastered surfaces on ceiling surface and applying three coats of white wash complete and all as specified and as directed
11M&L for complete removal of old surfaces on wall surfcesand applying two coat of exterior Acrylic emulsion paint (100% acrylic) of approved colour and shade over a coat of primer and over 1 to 2 mm thick birla putty punning including preparation of old plastered surface and scaffolding upto 4th floor complete all as specified and as directed by Engineer-in-charge.
12M&L for complete removal of old plastered surfaces of walland applying two coat of distemper oil emulsion by Auto Roller over a coat of wall primer over 2 to 3 mm thick cement based wall puttycomplete all as specified or as directed by Engineer-in-charge.
13M&L for complete removal of old surfaces on ceiling and applying three coats of white wash complete and all as specified and as directed
14Demolition of brick work or stone/boulders masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etac but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
15M&L forbrick work with sub class "B" bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 complete all as specified and directed by Engr-in-charge
16S&F Galvanised Steel Water Tubing 15mm Bore (dia), ‘Medium Grade’ with all Fittings, fixed to concealed or onWalls, Ceiling or laid in Floors or any other Situ-ation including Taking up down unserviceable Steel Water Tubing with Fittings and Connections, etc. complete all as specified and as directed.
17S&F Galvanised Steel Water Tubing 20mm Bore (dia), ‘Medium Grade’ with all Fittings, fixed to concealed or onWalls, Ceiling or laid in Floors or any other Situ-ation including Taking up or down unserviceable Steel Water Tubing with Fittings and Connections, etc. complete all as specified and as directed.
18S&F in repairs, 20 mm Bore gun metalGate/Globe half turn valves with iron wheel/Lever fixed-in-repairs complete all asspecified and directed byEngineer in charge.
19S&F Stop valves, fancy type 15 mm bore (dia) cast copper alloy, Plated, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or forunions and fixed-in-repairs complete all as specified and as directed.
20S&F Bib taps 15 mm bore (dia)cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule andfixed-in-repairs, complete all as specified and as directed.
21S&Ftwo way brass CP bib taps 15mm bore cast copper alloy with crutch or butterfly screwed down screwed for iron pipe or for brass ferrul and fixed in repair complete all as spd and as directed
22S&F in repair Brass CP towel rail 20 mm dia, including Taking down of old towel rail of any size, complete as all specified and directed.
23S&F Brass CP Health Faucet, as Approved, including Taking down unserviceable Health Fosset of any description, complete as all specified and directed. Make :- Cera, Johnsen, jaugar, Marc.
24S&F stainlessSteel Wire Cloth, 0.36mm nominal dia of Wire and average width of aperture 1.4 mm and fixed with Tinned Tacks of Mild Steel Wire Stapes, etc, complete all as specified and as directed.
25S&F Sheet Glass,4.0mm thick Ordinary, Glazing as in Window Frames fixed with Wooden oil putty/rubber beads, not exc. 0.50 Sqm in Each Pane and fixed in repairs, complete all as specified and as directed.
26S&F in repair,500 ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) three layered, ISI marked, hoisted and fixed in position including tank neeples of required size and 20 mm bore dia pipe ball brass valve high pressure with plolythelene float and flynutcomplete all as specified in SSR Part I complete all as specified and as directed.
27S&F in repair, 1000 ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) three layered, ISI marked, hoisted and fixed in position including tank neeples of required size and 20 mm bore dia of pipe ball brass valve high pressure with plolythelene float and flynutcomplete all as specified in SSR Part I complete all as specified and as directed.
28Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-charge.
29M&L 75mm thick plain cement concrete 1:3:6, type C-2 using 40mm graded aggregateas in plinth protection and court yard , finished even and smooth without using extra cement in panel and providing groves complete all as specified and directed by Engr in charge
30M&L for providing 75 mm thick cement concrete type B-2, 1:2:4 using 40 mm graded aggregate laid in path and hardstanding complete all as specified and directed by Engr-in-Charge.
31M&L Chequered Cement concrete tiles 300x300x25mm thick, set jointed and pointed in neat cement slurry in floors with white cement and pigments in any colour ,over and including cement screed bed 15mm thick cement mortar 1:4 all as specified and as directed
32Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) & remove rubbish from MoD Land, complete all as specified and directed by Engr-in-charge
33M & L for non-skid ceremic colour tile size of7 to 8 mm thick(square/rectungular) area exc. 0.06 Sqm but not exc 0.11 Sqm laid in floors setting and jointed with neat cememy slurry over and including 15 mm thick screed bed in cement mortar 1:6, and pointed with coloured cement to mathc with surfaces of tiles, complete all as specified and directed by Engr-in-charge
34M&L non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular ) area of each tile exceeding0.11 sqm but not exceeding 0.18 sqmin floors etc , set and jointed in neat cement slurry andpointed in white/coloured cement to match over and including15 mm thick screed bed in cement mortarin(1:6) completeall as specified and as directed by Engineer-in-Charge.
35M&L for Glazed ceramic coloured tiles in vertical surface 450 x 350 x 7 to 8 mmthick set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 10mm thick screed bed in cement mortar 1:4 Laid and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed.
36Dismantling of old existing CI/concrete pipes of any description, jointed in cement mortarup to 100 mm dia and removing from site complete all as specified and as directed.
37S&F in repair PVC (SWR) Pipes 110mm in Bore (dia), Single Socketed, in any length with Rubber Ring Joints fixed to Walls/Floors, etc, including Taking down /up unserviceable Pipe, complete all as specified and as directed.
38All as per item No 36 above but 75 mm bore -ditto-.
39Supply only liquidwater proofing compound complete all as specified and directed.
40S&F PVC (SWR) Bend suitable for PVC (SWR) Pipes 75mm in Bore (dia) with access door, jointing with Solvent Cement and fixed-in-repairs, complete all as specified and as directed.
41S&F 75 mm dia PVC (SWR) Tee with access door suitable for PVC (SWR) Pipes 75mm in Bore (dia), jointing with Solvent Cement and fixed-in-repairs, complete all as specified and as directed.
42S&F 75mm dia sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints fixed to walls complete all as specified and directed.
43S&F 100mm dia sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints fixed to walls with oval access door complete all as specified and directed.
44S&F in repair 75mm dia CI bends with oval access door, diminishing pieces or tapers complete all as specified and directed.
45S&F in repair 100mm dia CI bends, diminishing pieces or tapers complete all as specified and directed.
46S&F in repair 75mm dia CI branch pieces, single (equal or unequal) ordinary or inverted (Spigot or socket type) or with paralled branches with ovel access door complete all as specified and directed.
47S&F in repair 100 mm dia CI branch pieces, single (equal or unequal) ordinary or inverted (Spigot or socket type) or with paralled branches with ovel access door complete all as specified and directed.
48S&F in repair stack clamp made out of GI angle and 10mm dia U bolt and nut with washer for 75 and 100 mm dia pipe complete all as specified and directed.
49Demolition of reinforced cement concrete placed in any position including cut of bars as required, complete all as specified and directed.
50M&L for Reinforced cement concrete (nominal mix) 1:2:4 type B-1 using 20 mm graded aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs shelves , Chhajja and the like etc including necessary formwork complete all as spd and directed
51M&L for MS TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
52Re-baring by drilling holes and fixing nozzle if required in existing concrete/brick work as in column, beams, slabs and foundation etc in any position and any description size of hole 14mm, 16mm & 22mm suitable for dowels of size 10mm, 12mm & 16mm respectively (minimum depth 140mm for 10mm & 12 mm dia bars and 180mm for 16mm dia bar, cleaning the surface properly with blow out pump & round brushes and fixing of dowel bars with epoxy resin (resin+hardner).Make: Sika, Fosroc or concressive 1450 of BASF complete all as specified and directed by Engr-in-charge. Note:-(i)Adequate lap length shall be provided as per IS-456-2000. (ii)Reinforced TMT bars where incorporated in work will be paid under the relvent items. (iii)The work shall be carried out upto four storied building with scaffolding and in patches as directed by Engr-in-charg e. (iv) Rate for scaffolding and formwork wherever required and as directed to be included in quoted rate. (v) The works will be executed in different buildings and at scattered locations.
53Removal of demolish material debris/malwa/surplus soil to a distance exc 10 Km but n exc 15.00 Km out side MD land and depositing where as directed, complete all as specified and directed by Engr-in-charge.
54M&L for gunniting to RCC works in column,beams, slabs, chajja, facia, landing, balconies and similar wks etc by removing/ dismantling of RCC(loose concrete) including plasterand cutting of steel barincluding cleaning of surfaces with wire brushes and applying epoxy, paint anti corrosive coating of minimum 40-50 microns thick with sikatop Armatec 108 or Colusal VL of MC Bauchemie to rusted steel reinforcement after removing cleaning all rust and supply and fixing with sufficient fasteners/concrete nails/welding at regular intervals welded steel wire mesh 75mm x75mm with 4mm dia steel wire as faces/drops and applying epoxy based or other equivalent suitable bonding against treatment to be carried out on old concrete surface with Sikadur 32 of Sikka.Nito bond EP of fosroc or equivalent (as per manufacturers instruction) to bond old and new concrete mixing @ 2% by weight of cement polycrete and providing gunniting with a minimum pressure of 2 to 2.5 Kg sqcm with varying thickness from 25mm to 100mm as per requirement at site gunniting in cement mortar (1:2) (one part of cement and two part of ghaghar sand) and plastering in cm 1:4 to a uniform surface, wherever required at any height, location and position complete all as specified and directed by Engineer-in-Charge. Note:-(i)After placing the additional reinforcement all concrete surface shall be thoroughly scrubbing with. (ii)Additional reinforced TMT barswere incorporated in work however min 20mm thick cement plaster in 1:4 and necessary connected wks related to gunniting to be included in quoted rate. (iii)Work to be carried out as in patches as directed by Engr-in-charge. (iv) Rate for steel scaffolding and formwork wherever required and as directed to be included in quoted rate. (v) All demolished material removed from MOD land completely. (vi) The works will be executed in different buildings and at scattered locations.
55Dismantling ofexisting roof Tile/treatment any size/description all as specified and directed by Engr-in charge.
56Cleaningtop surfaces by brooming, wire brushing, removing grass, raking out joints to receiveplaster and removing debris, grass etc outside the defence land completeall as specified and directed by Engineer-in-Charge.Note :-1. Plaster shall be measuredandseparately under appropriate item of Sch ‘A’.2.Rate of this item is inclusive of diconnectfitment at water tank orsolar heater etc and refixing in the same position after compeleting of roof treatment.
57M&L water proofing treatment on roof and vertical surface consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm on plaster surface all as specified. (c) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/ sqm), duly sealed at over laps & joints with end laps of the 10cm and side over laps of 7.5cm by flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed.
58Pre construction Anti termite treatment for filling under floor/Plinth Protection by using CHLROPYRIPHOS 20% EC emulsion @5.00Ltr/Sqm complete all as specified and as directed.
59Pre construction Anti termite treatment along the outer periphery of building by using CHLROPYRIPHOS 20% EC emulsion @2.25 0Ltr/Rm complete all as specified and as directed.
60M & L for 100mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor, path and hard standing complete all as specified and as directed.
61M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishinglaid over 15mm thick screed bedding layer in CM 1:4 for laying in floor etc complete all as specified and as directed by the Engr-in-charge
62M&L Machine cut kota stone 15-20mm thick as in skirting over 10mm thick rendering in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and finishing with mirror polishing complete all as specified and as directed by the Engr-in-charge
63M&L for 15mm thick rendering on brick or concrete surfaces in internal surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
64M&L for preparation of newely plastered Wall surface and applying three coats of white wash complete and all as specified and as directed
65M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in coping, benching, bed block, window cills etc complete all as specified and as directed by Engr-in-charge
66Dismantling wought iron or mild steel work of any description not otherwise provided forcomplete all as specified and as directed by Engr-in-charge
67S & F steel rolling shutters (thickness of laths in 1.25mm),without ball bearing,as specified including top cover,anchoring rod,hasps and staple and one shop coat of primer :erected in position as indicated complete but gear operated type with bevel gear box and cranck handle complete all as specified and as directed by Engr-in-charge
68S&F safety lever locks mild steel with 4 lever for rolling shutters complete all as specified and as directed.
69S&F ball bearing for rolling shutters complete all as specified and as directed.
70M&L Preparation new or previously untreated steel surface of any description, over 10 cm in width or girth applying two coat synthetic enamelpaint over one coat of red oxide zinc chrome primer over complete all as specified and directed by Engr-in-charge.
71M&L for Complete removal of existing old treatment by scraping down with steel brush/steel patty preparing old plastered surface of walls and applying two coats of white wash complete all as specified and directed.
72Dismantling of asbestos cement sheet corrugated or semicorrugated etc in roofcovering etc.complete all as specified and directed.
73S&F 0.50 mm thickpre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screwscomplete all as specified and directed.
74S&F MS framed work as in doors or gates of angle or other section as chowkhat., tie bar, hold fast, guard bars, Chajja etccomplete cooler stand etc, drilled for fixingcomplete Fe-410complete all as specified and directed.
75M&L for complete removal of existing old treatment by scraping down with steel brush/steel patty preparing old plastered surface of ceiling and applying two coats of white washcomplete all as specified and directed.
76M&L for 15 mm thick cement plasteringin CM 1:4 on brick/concrete surfaces of roof and parapet, mixed with water proofing compound, finished even and smooth without using extra cement (Including 4 Story building) complete all as specified and as directed by Engineer-in-Charge. Note :- Water proofing compound shall be measured & paid separately.
77E/M Portion
78Taking down copper/aluminium point wiring (light points) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for the above items should be made as per conditions seperately) and making good disturbed surfaces of walls. floors, etc. complete all as directed
79Taking down carefully by unscrewing from theboards/outlets boxes fittings and fixturessuch as switches, sockets ceiling, rose, lamp holders, tube light fittings, regulators etc and making good of disturbedsurfaces complete all as specified and as directed.
80Taking down ofexisting old unserviceable submain wiringcomplete all as specified and as directed.
81Taking down ofexisting old unserviceable MCBof any ratingcomplete all as specified and as directed.
82Taking down ofexisting old unserviceable VTPN distribution board with MCCB of any type complete all as specified and as directed.
83Taking down of LED tube light /Ceilling light/Round light/ Bulkhead light of any type and capacity complete all as specified and as directed.
84Material & Labour for concealed point wiring with single core PVC insulated and unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sqmm nominal area drawn through & including non metallic rigid PVC conduit (circular/flat pvc conduit), medium duty not less than 20 mm dia concealed in wall/fixed on wall/ceiling with GI saddles , GI screws , rawl plugs with all fittings including tees , junction boxes & provision for modular box and modular cover of suitable size for mounting modular switches , sockets & regulators & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper conductor solid conductor of size 1.5 sqmmcomplete all as specified & directed by Engineer -In-Charge. Note: Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate.
85One light point controlled by one single pole switch & socket.
86One 3 pin sockets outlet 5 Amps on the same board with other switches with cable of size 1.5 sqmm
87One 3 pin sockets outlet 5 Amps independent with cables 1.5sqmm size
88All as per Srl item No. 83.01 above butsocket outlet independent but below the switch board of light points in the same vertical plane, with cables.2.5 sq. mm size
89Supply and Fixing of modular switches 1 way, 6 Amp 1 module complete all as specified & directed.
90Supply and Fixingmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified & directed .
91Supply and Fixing of modular switches 1 way, 16 Amp 1 module complete all as specified & directed .
92Supply and Fixingmodular Socket 6A/16A - 2/3 pin combined 2 module, ccomplete all as specified and as directed.
93Supply and fixing LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
94S&F submain wiring withunsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 20mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 2.5 Sqmm single core HR Grade and one run of 2.5 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB points complete all as specified and as directed. Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
95S&F submain wiring withunsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 20mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 1.5 Sqmm single core HR Grade and one run of 1.5 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB points complete all as specified and as directed. Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
96S&FGI Modular gang sunk-in pressedterminal boxes of required size not less than 1.2 mm thick factory made for following module complete all specified and directed. Note: Flushing of module box in wall with cement and repairing the wall as before is deemed to be included in quoted rate.
97Metal flush box 3 module
98Metal flush box6 module
99S&F white cover plate with frame of following module complete all specified and directed.
100white cover plate with frame 3 module
101white cover plate with frame 6 module
102Supply and fix in replacement of factory made epoxy polyster powder coated VTPN distribution boardTriple pole MCB4 way 415V fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, provision for 63 Amps MCCB as one incommerand 12 outgoings single pole MCB with 2 Neutral bar, 2 Earthbar, Fully insulated busbar rated capacity above 63 Amp, shrouded Neutral bars and cable ties for cable management complete all as specified and confirming to IEC 61439-3,Reversible door IP 43 & IP 54 complete all as specified and directed. Make: Legrand /Siemens/Schneider. Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.
103Supply & Fixing MCCB 63 Amps4 Pole, 415 V, fixed thermal & fixed magnetic setting electromechanical type with Ics=75 % of Icu , with breaking capacity 16 KA conforming to IS: 13947-II complete all as specified and as directed.
104S&F in replacement of MCB SP 6-32 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .
105Supply , Laying , testing and commissioning in replacement of XLPE insulated and PVC Sheathed , galvanized steel strip or wire armoured , heavy duty electric cable with multi stranded aluminium conductor, 1100 volts grade of size 16 sqmm 4 core complete all as specified & directed by Engineer - In - Charge.
106Note:- The amount of Rs 40308/- against Schedule of Credit on Page No 145 shall be deducted from the total amount quoted against Sch "A"while deriving the Contract Sum for Acceptance