Tender For Construction Of 08 Bedded Mahila Barrack At Bop Roop Nagar Instead Of Bop Khanpur 59 27 Of 55 Bn Bsf Under Shq Bsf Abohar Sh Ei And Fans I C Service Connection, Fazilka-Punjab

Border Security Force-BSF has published Tender For Construction Of 08 Bedded Mahila Barrack At Bop Roop Nagar Instead Of Bop Khanpur 59 27 Of 55 Bn Bsf Under Shq Bsf Abohar Sh Ei And Fans I C Service Connection. Submission Date for this Tender is 26-12-2023. Barrack Tenders in Fazilka Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

40947544
Tender For Construction Of 08 Bedded Mahila Barrack At Bop Roop Nagar Instead Of Bop Khanpur 59 27 Of 55 Bn Bsf Under Shq Bsf Abohar Sh Ei And Fans I C Service Connection
Open Tender
Indian
Punjab
Fazilka
26-12-2023

Tender Details

Construction Of 08 Bedded Mahila Barrack At Bop Roop Nagar Instead Of Bop Khanpur 59 27 Of 55 Bn Bsf Under Shq Bsf Abohar Sh Ei And Fans I C Service Connection

Key Value

Document Fees
Refer document
EMD
INR 16269.0 /-
Tender Value
INR 8.13 Lakhs /-

BOQ Items

Name of Work: “CONSTRUCTION OF 08 BEDDED MAHILA BARRACK AT BOP ROOP NAGAR INSTEAD OF BOP KHANPUR (59/27) OF 55 BN BSF UNDER SHQ BSF ABOHAR (SH : EI & FANS I/C SERVICE CONNECTION).”
Sl. No. Item Description
1SUB HEAD-I (WIRING)
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Group B)
3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
4Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (ii) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
5Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
6Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 4 sq. mm
7Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. ( 20 mm)
8SUB-HEAD-II (FITTING AND ACCESSORIES)
9Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
10Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
11Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
12Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
13Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
14Supplying and fixing PVC batten holder including connections etc. as required.
15Providing and fixing of 9/10 watt Led bulb in existing holder etc complete as required .
16Supply, installation, testing and commissioning of 20 watt LED tube fittings comprises of extruded channel in thermally conductive material ,high translucent serrated milky white diffusers used to get glare free and smooth light distribution, efficiency :100lm/w and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required.
17Providing and fixing of 1200 mm sweep BLDC ceiling fan , including wiring the down rods of standard length (upto 30 cm) including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
18Supplying,Installation, testing and commissioning of heavy duty exhaust fan, metalic body 230V,300 mmsweep,single phase including making the hole to suit the size of the above fan, making good the damage i/c P/F louver and shutter complete with frame for exhaust fan of size connections,testing and commissioning etc as required.
19Supplying installation testing and commissioning of wall fan 230V,400 mmsingle phase on the wall including connection testing and commissioning etc as required.
20Supply, installation, testing and commissioning of 10 watt LED tube fittings comprises of extruded channel in thermally conductive material ,high translucent serrated milky white diffusers used to get glare free and smooth light distribution, efficiency :100lm/w and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required.
21Providing and fixing of 12 watt surface mounted LED fitting square/Round directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. .
22Providing and fixing of 50 watt LED flood light made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection, system efficiency >110/120LPW, 10KV SPDversion to be ordered separatelyincluding connection, testing commissioning etc as required.
23Providing and fixing of electric storage water heater of 25 ltr of 2 KW ,240 Volt ,50 HZ i/c fasteners with nut, bolts, washers and connection pipe with connection, testing commissioning etc as required .
24Providing and fixing of smart incinerator for disposal of used sanitary pads with suitable size of exhaust pipe including connection, testin & commissioning etc as required which having following technical specification below:-i) Watt-1200 Watt ii) Capacity -50-55 Pads/ day iii) Auto Cut off Function iv)Ash - after burn less than 1 gm/ Pad v) Dimension -220L X 220W X 360HVI ) Type - wall mounted
25SUB-HEAD-III (MCBs & DBs)
26Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. (For 4 way (4 + 12), Double door TPN MCB DB)
27Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 4 way (4 + 12), Double door
28Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. (For 10 way, Double door SPN MCBDB)
29Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (2 + 8 way, Double door)
30Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single pole )
31Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Double pole )
32Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 15 KA - 18 KA,TPMCCB
33Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
34SUB-HEAD-IV (EARTHING)
35Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
36Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
37Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
38Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. (2 X 25 sq. mm (22mm)
39SUB-HEAD-V (DUCT COOLER)
40Providing and fixing of maintenance free, dust and moisture free,Engineering plastic injection moding Cooler Body, Cooling pad- 4D honey combo cellulose wet pad with anti bacterial resins fibre body ducting air cooler of following specification : Air flow 18000 CMH, Cooling area 2500 sqft (without ducting), Motor-Inverter high torque motor 380 to 415 volt/50 Hz, 1.1 Kw ( Single phase turbo axial fan) with 1400 RPM, , Air pressure - 180 P.A., Water tank capacity - 35 Ltr, Air outlet size - 670 mm x 670 mm,etc as per direction of engineer in charge. Make - Sky air cooler model URANUS or equivalent make and model in Symphony, Maharaja, Cool wind complete as per requirement or as decided by Engg-In-Charge.
41Providing and fixing of angle iron frame of suitable size for placing of duct cooler made out of 50 mm x 50 mm x 5 mm thick angle iron including making of stand as per site requirement and installation of duct cooler, as per direction of Engg- in -Charge,
42Suppling and making of duct made of 24 Gauge GSS sheet of suitable size as per site requirement andducting will be insulated with high quality insulating material etc as required as per direction of Engineer- in- Charge at site.
43Supplying and fixing of the heavy duty air controlling louvers/ shutters with manually operated adjustable blades complete with matelic frame as per site requirement.
44Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
45Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(i) 20 mm nominal dia Pipes
46Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per direction of Engineer in Charge. Make : Syntex / Modi (Circular tank)
47SUB-HEAD-VI (SOLAR SYSTEM)
48Providing & fixing 1.5 KVA, 24 volt single phase PWM SOLAR power package 24 V rated solar power conditioning unit, 3X325 Wp Solar PV Module having nominal voltage 24V, 02 nos LMCA C-10 rated 12 V, 150 AH tubular maintenance free solar battery (05 year warranty)including galvanized iron stand, internal wiring withPVC insulated copper wire, junction box, civil work etc as per manufacturer specification required. The solar PCU unit should consists of following:- a)Solar charge controller:- Single phase solar charge controller based on PWM technology, max input PV Current40 A, , protection against overcurrent, battery over charge, PV/Battery reverse polarity, reverse current & High temprature b) Inverter:- 24 V DC input and 220 V pure sine wave output at rated load 1 KVA @ .8 PF, efficiency>=85% c)Earthing:3 no"s Chemical Earthing Material as per Roof top requirements Chemical Earthing System and Lighting arrestor with Stranded Copper wire. d)Wiring (Tin Coated UV protected DC Wire e) MC4 Connector/conduit/Cable tie/tray/wiring Make- As per manufacturer specification and as per direction of engineer in charge
49Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. A) All kinds of soil Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level
501:5:10 (1 cement : 5 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 10 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA)
51Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
52Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge
53Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade
54SUB-HEAD-VII (PANELING AND CABLELING)
55SITC of various sizes water protected outdoor (Water proof)huttype compartmentalized type double door cubical panelboth side opening havingdepth up to 450 mmsuitable for 415 Volt, 3 phases, 50 Hz made out of 2mm thick CRCA sheet with required hardware duly painted with powder coated .Panel having separate detachable gland plate, angle iron base frame made out of 50mmx50mmx5mm angle iron of suitable size of the feeder pillar (minimum height 60cm), hinged door, both side opening with locking arrangement, earth bar/stud, led pilot light for phase indicator (R,Y,B) on top, 200A/415V 4 strip aluminum bus bar duly PVC sleeved, connection inter–connection with 25% extra current carrying capacity busbars to MCCBs spreader links and with solid copper conductor cable 10 sqmm/ solid aluminium rodfor connection toMCBs and heavy duty connectors of required current carrying capacity to be fixed back side including incoming/Outgoing cables connection for three and single phaseMCBs where as required, testing on loadand marking of location for incoming and out going distribution i/c grouting the legs in existing floor with 1:3:6 cement concrete foundation and dsimantling the existing panel, incoming/outgoing cable connections etc complete as required i/c dismentling the existing feeder pillar and UG cable. (Panel should beas per design &drawing approved by Engg in charge).LED light min 5 watt with on/off switch to be provided in the panel.
56Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 4 x 25 sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
57Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 4 x 25 sqmm in the existing RCC/ HUME/ METAL pipe as required.
58Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 2 x 25 sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
59Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 2 x 25 sqmm in the existing RCC/ HUME/ METAL pipe as required.