Tender For Provision Of Otm Accommodation & Allied Facilities For Inf Bn No 3 At Along Under Cce ( Army ) No 1, Dinjan ( Tender Id :2023_Mes_611168_3 ), dinjan-Assam

Military Engineer Services-MES has published Tender For Provision Of Otm Accommodation & Allied Facilities For Inf Bn No 3 At Along Under Cce ( Army ) No 1, Dinjan ( Tender Id :2023_Mes_611168_3 ). Submission Date for this Tender is 02-01-2024. Building Work Tenders in dinjan Assam. Bidders can get complete Tender details and download the document.




Tender Notice

40930815
Corrigendum : Tender For Provision Of Otm Accommodation & Allied Facilities For Inf Bn No 3 At Along Under Cce ( Army ) No 1, Dinjan ( Tender Id :2023_Mes_611168_3 )
Open Tender
Indian
Assam
dinjan
02-01-2024

Tender Details

Provision Of Otm Accommodation & Allied Facilities For Inf Bn No 3 At Along Under Cce ( Army ) No 1, Dinjan ( Tender Id :2023_Mes_611168_3 ) ; Total Amount Of Sch A Part I ( Building And Structure ) ( Pre Priced Amount As In Col 7, Brought Forward From Total Of Sch A Part-I ) 2 Total Amount Of Sch A Part Ii ( Dismantling And Demolition Of Buildings ) ( Pre Priced Amount As In Col 7, Brought Forward From Total Of Sch A Part Ii ) 3 Total Amount Of Sch A Part Iii ( Site Clearence, Earth Work Andarea Development ) ( Pre Priced Amount As In Col 7, Brought Forward From Total Of Sch A Part Iii ) 4 Total Amount Of Sch A Part Iv ( Retaining Wall ( For Height Upto 5.5 M ) ( Pre Priced Amount As In Col 7, Brought Forward From Total Of Sch A Part Iv ) 5 Total Amount Of Sch A Part V ( Internal Electrificationand Lightning Protection ) ( Pre Priced Amount As In Col 7, Brought Forward From Total Of Sch A Part V ) 6 Total Amount Of Sch A Part Vi ( Internal Water Supply ) ( Pre Priced Amount As In Col 7, Brought Forward From Total Of Sch A Part Vi ) 7 Total Amount Of Sch A Part Vii ( Road / Path / Culvert ) ( Pre Priced Amount As In Col 7, Brought Forward From Total Of Sch A Part Vii ) 8 Total Amount Of Sch A Part Viii ( External Electrification ) ( Pre Priced Amount As In Col 7, Brought Forward From Total Of Sch A Part Viii ) 9 Total Amount Of Sch A Part Ix ( External Water Supply ) ( Pre Priced Amount As In Col 7, Brought Forward From Total Of Sch A Part Ix ) 10 Total Amount Of Sch A Part X ( Sewage Disposal ) ( Pre Priced Amount As In Col 7, Brought Forward From Total Of Sch A Part X ) 11 Total Amount Of Sch A Part Xi ( Area Drainage ) ( Pre Priced Amount As In Col 7, Brought Forward From Total Of Sch A Part Xi ) 12 Total Amount Of Sch A Part Xii ( Fencing And Gate ) ( Pre Priced Amount As In Col 7, Brought Forward From Total Of Sch A Part Xii ) 13 Total Amount Of Sch A Part Xiii ( Solar Water Heating System ) ( Pre Priced Amount As In Col 7, Brought Forward From Total Of Sch A Part Xiii ) 14 Dismantling And Demolition Of Buildings 15 Taking Down Old Copper / Aluminium Point Wiring ( Light, Fan Socket Or Power ) Complete, Including Fixture And Fittings Such As Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings Etc, Complete All As Specified And Directed. 16 Taking Down Ceiling Fan / Exhust Fan, Of Any Size And Capacity And Deposite To Mes Store Yard Complete All As Specified And Directed. 17 Taking Down Mcbsdb And Connected Service Cable Of Any Type, Capacity And Size Complete All As Specified And Directed. 18 Taking Down Geyser Of Capacity Upto 25 Lts In Any Position And Situation And Deposite To Mes Store5 Yard Complete All As Specified And Directed. 19 Internal Electrification & Lightening Protection:- 20 Supply And Fix Flame Proof / Weather Proof Rotary On / Off Switch Complete All Asspecified And Directed 21 M & L For Concealed Flush To Wall Factory Made Sheet Metal Enclosure For Mcb Dbs, Manufactured Prewired Double Door Designed, DbS Vtpn 415V12 Way 63 Amp Fixed On Wall / Ms Box Complete With Copper Bus Bar Neutral Link Dinrail Suitable For Mounting MccbS Complete, Ip-54 Protection Complete All Asspecified And Directed. 22 M & L For Concealed Flush To Wall Factory Made Sheet Metal Enclosure For Mcb Dbs, Manufactured Prewired Double Door Designed, DbS Vtpn 8 Way63 Amp Fixed On Wall / Ms Box Complete With Copper Bus Bar Neutral Link Dinrail Suitable For Mounting MccbS Complete, Ip-54 Protectioncomplete All Asspecified And Directed. 23 S & Fled Tube Light 22 Watt Delite Plus Led Tube Light , 6500K Surface / Recess Mounteddecorative Ultra Slim Aluminium Square Profile Led Lighting Fixture With High Lumen Output, Environmental Friendly, Energy Efficient, Etc Complete With All Accessories Internally Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Sizecomplete All Asspecified And Directed. Make:- Havells Or Equivalent Make As Approved By Pm. 24 S & Fled Tube Light 20 Watt E-Lite Led Pride Plus , 6000K Surface / Recess Mounteddecorative Ultra Slim Aluminium Square Profile Led Lighting Fixture With High Lumen Output, Environmental Friendly, Energy Efficient, Etc Complete With All Accessories Internally Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Complete All As Specified And Directed. Make:- Havells Or Equivalent Make As Approved By Pm. 25 S & F Flame Proof Led 20 Watt Cmri Certified Led Flameproof Suitable For Gas / Vapor Group Of Iia & Iib And Zone 1 & 2. Ip65 Protection, Complete With All Accessories Prewired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Complete All Asspecified And Directed Make- Crompton Or Equivalent Make As Approved By Pm. 26 S & Fled Tube Light 18 Watt E-Lite Led Pride Plus , 6000K Surface / Recess Mounteddecorative Ultra Slim Aluminium Square Profile Led Lighting Fixture With High Lumen Output, Environmental Friendly, Energy Efficient, Etc Complete With All Accessories Internally Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Complete All Asspecified And Directed. Make- Crompton Or Equivalent Make As Approved By Pm. 27 S & F Led Tube Light 2X18 Watt Magnum Retro, Long Life, Corrosion Resistant, Impact Proof, Surface Mounting Ip65 Luminaire With Pc Housing & Opal Finish Cover Suitable For Led Tubes, Etc Complete With All Accessories Internally Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Complete All Asspecified And Directed Make- Crompton Or Equivalent Make As Approved By Pm. 28 S & F Bulk Head With 10W Led Light ( Cat No. Lheoaop7uz6w010 ) With All Accessories Suitable For Fitting And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Of 230V, 50Hz Complete All Asspecified And Directed. Make- Crompton Or Equivalent Make As Approved By Pm 29 S & F 6 Watt Led Light For Mirror4000k Ac 170-240V, Complete With All Accessories Prewired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Complete All Asspecified And Directed. 30 S & F 24W Recess Mounted Downlighter With Pressure Die-Cast Aluminium Heat Sink & Pc Diffuser In White Powder Coated Finish With Integrated Driver. Product Desvription 24W 830 Complete With All Accessories Prewired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Complete All Asspecified And Directed.Make- Havells Or Equivalent Make As Approved By Pm 31 S & F 15 Watt Edge Plus Series Led Street Light ( Cat No. Brlep 15W Led ) Pressure Die Cast Housing With Toughened Glass And Individual Leds With Secondary Optics And Ip65 Protection, Complete With All Accessories Like Gi Pipe Suitable For Fitting And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Of 230V, 50Hz. Complete All Asspecified And Directed. Make- Bajaj Or Equivalentmake As Approved By Pm 32 S & F Hd 750 Mm Sweep ( Ss-390 Metallic ) Ceilling Fan Including Cost Of Material, Labour And T & P As Per Drawing Complete, For Proper Completion Of Work Complete All As Specified And Directed. Make:- Crompton / Khatian / Havells / Orient 33 S & F Telephone Jack Modular With Shutter Type Fixed On 2 Module White Cover Plate With Fram, 2 Module Metal Flush Box Complete All As Specified And Directed. 34 S & F Drawing Twin Core Telephone Wire 0.5Mm In Pvc Conduit Of 25Mm Size Complete In All Respect, Including Cost Of Material, Labour And T & P As Per Drawing Complete All As Specified And Directed. 35 S &F T.V Socket With Shuttertype Fixed On 2 Module White Cover Plate With Fram, 2 Module Metal Flush Box Completedrawing 25Mm Dia Pvc Concealed Conduit Connection Complete In All Respect Complete All As Specified And Directed. 36 S & F Co-Axial Tv Cable Electrolytic Grade Solid Annealed Copper Conductor, Jf, Al Wire Braided ( Rg-6 Foam Type ) In Pvc Conduit Of 25Mm Size Complete In All Respectcomplete All As Specified And Directed. 37 Road / Path / Culvert :- 38 M & L For Applying 3Mm Thick Retro Reflective Thermoplastic Road Marking Paint Using Thermoplastic Road Marking Compound, Conforming To Morth, Aahto M249 And Bs 3262 With 30-40% Pre Mixed Glass Beads Conforming To Bs 6088, On Existing Road Surfaces Including Preparation Of Surface Complete All As Specified And Directed. 39 S & F Cat Eyes / Glow Studs Of Size 100X100x20mm, Made Of Heavy Duty Body Fixed On The Road As Per ManufacturerS Instructioncomplete All As Specified And Directed.. 40 S&F Sign Boards On Road As 900Mm X 600Mm Size, As Per Irc Made Out Of 2.0Mm Thick Aluminium Sheet With Front Face Of Aluminium Sheet To Be Fully Covered By White Diamond Grade Micro Prismatic Type 1 X Retroreflective Sheeting Matter By Over Lay Red Colour Film And Back Side Painted With Grey Appoxy Paint Including Fixing Provision Of 1 Post Of Ms Pipe 75Mm Dia 3.80M Long Dully Painted In Black And White Alternate Bands Of Synthetic Enamel Paint And Hold Fast At Bottom Complete In All Respects All As Approved By Pmcomplete All As Specified And Directed. 41 External Electrification :- 42 Supply, Install, Testing And Commissioning Of Ht 11 Kv, 18.4 Ka, 3 Phase, 50 Hz 3 Wire Totally Enclosed Metal Clad , Extensible Type Indoor Floor Mounted Horizontal Draw, Horizontal Isolation Type Vacuum Circuit Breaker 400 Amps Motor Operated Spring Charged Having Rupturing Capacity 250 Mva And Consisting Of The Following :- 01No 11Kv, 400 Amps, Vcb Comprising Of :- ( I ) Assembly Of 3 Vaccum Interrupters Complete With Epoxy Support Insulator And Self-Aligning Finger Type Isolating Contacts. ( Ii ) Hand And Motor ( 220 Volt Ac ) Charged Independent Spring Closing / Tripping Trip Free Operating Mechanism With Manual Closing And Tripping Push Buttons And Mechanical Breaker Closed / Open, Spring Charged / Discharged Indication. ( Iii ) Electrical Release Coil 24V Dc- 01 No ( Iv ) Mechanical Operation Counter. ( V ) Breaker Operated Auxiliary Switch-03 Nos ( Vi ) Bus Bar Chamber Including A Set Of 3 Phase 630 Amp Copper Bus Bar -01 No ( Vii ) 230 Volts Ac Single Phase 80 W Rated Strip Type Heater -02 Nos With Indicator Complete. ( Viii ) Voltagetransformer ( Vt ) Incorporating 3 Phase 3 Limb With Drawable Type Vt Having Ratio 11Kv / 110V And Output Of 100 Va Per Phase With Accuracy Class I As Per Is-3155 Complete With Ht And Lt Hrc Fused N Primary And Secondary Sides Respectively ( Confirming Related Is Specification ) -02 Set . ( Ix ) Current Transformer ( Ct ) Chamber Incorporating 3 Single Phase Resin Cast, Dual Ratio Cts Of Ratio 40 / 20 / 5 Amp With Suitable Va Burden And Accuracy Class. ( J ) Rear Cable Termination Provision For Terminating 3 Core 120 Sq. Mm Xlpe Cable. ( X ) Ammeter Dual Range With Selector Switch Size 144 Sq. Mm 0 20 / 10A. ( L ) Voltmeter With Selector Switch 43 ( Xi ) Triple Pole Non-Directional Idmt Relays Having Minimum 02 Element For Over Current Setting 50% -200% And One Element For Earth Fault Protection Setting 20%-80% With Instruments High Set Element -01 ( Xii ) On / Off / Trip Indication-01 ( Xiii ) Tnc Switch-01 ( Xiv ) 3 Phase Ryb Indications With Lamp & Holder - 01 Set With Cable Glands Of Suitable Size ( Xiii ) Trip Circuit Healthy Indication Lamp With Push Button-01 ( Xv ) Power Factor Meter Digital Type-01 ( Xvi ) Frequency Meter -01 ( Xvii ) Cable Gland Of Suitable Size ( Xviii ) Shunt Trip 24 Volts Dc Including Maintenance Free Battery Bank, Batterycharger ( Xix ) In Built Integral Earthing ( Xx ) Electronic, Digital Kwh Meter Ct Type Suitable For Metering Ct-01 No.Complete All As Specified And Directed. Make Crompton / Schneider / Abb / Ite Gurgaon 44 Supply And Installation Of 11 Kv Single Phase In Door Resin Cast Ct Of Ratio 400 / 5- 5A Class 1.0 / 5P10, Burden 15Va – 15 Va, Including All Connectioncomplete All As Specified And Directed. 45 Supply And Installation Of 11 Kv Single Phase In Door Resin Cast Pt Of Ratio 11 Kv / Rt3 / 110 V / Rt3 / 110V / Rt3, Class 0.5-3, Burden 50 Va – 50 Va, Including Cost Of Material, Labour Including Making All Connectioncomplete All As Specified And Directed. 46 Supply And Fix Ht 11 Kv, Out Door Type Gang Operated Air-Break Switch Suitable For Horizontal Or Vertical Mounting Fixed Type Complete With 9 Insulators Of Rating Upto 200 Amps, Complete All As Specified And Directed. 47 Supply And Fix Lightning Arrestor Ht 11 Kv 10 Ka Station Class, Duly Fixed On Two Pole Structurecomplete All As Specified And Directed. 48 Supply & Install, Testing And Commissioning Indoor Type 30 Volts Battery Bank Including Charger Suitable For And Including 15 C Batteries Of 120Ahinput Supply Single Phase 230 Volts And Output Float 24-35 Volts Dc @10 A, Boost 29 Volts At Power Factor 0.8 And Degree Of Protection Ip 4X, Complete Internal Wiring With Suitable Copper Condutor Wires And Each Battery & Charger Should Bemounted In The Same Panel With Suitable Ventilation, Floor Mounting Panel Fabricated Out Of 2 Mm Thick Crca Sheetwith Suitable Angle Iron Frame And Legs Made Of Suitable Angle Iron, Painted With Powder Coated And Pre Coted Primer Including With Locking Arrangement Complete All As Specified And Directed By Engr-In-Charge. Make : Abb / Schnieder / Seimens / L & T 49 Supply, Installation Testing And Commissioning Of Digital Ups System For Power Back Up Single Phase Ac Input 140Vto 270V And Out Put 220V + 10% Capacity 4 Kva Including 02 Nos , 12V Batteries Of 150 Ah, Vrla ( Valve Regulated Lead Acid Batteries With Interconnection Cables And Battery Rack Complete All As Specified And Directeed. 50 Supply & Laying Synthetic Insulating Mat Of Size 2.00Mtrx 1.00Mtrx 19 Mm Thickcomplete All As Specified And Directed . 51 Supply And Fixing 40 Mm Dia Gi Pipe For Street Light Bracket On Lt PoleMedium GradeOf 1.5 Mtr Long And Make To Shape Fixing With Suitable Size Of Flat Iron Clamp Nut , Bolts And Washers Connection Including Two Coat Of Synethetic Enamel Paint Over A Coat Of Red Oxide Zinc Chrome Primer And Fixing The Light Fitting On Bracket And All The Electrical Connection Complete All As Specified And Directed. 52 Supply And Fixing Led Street Light Fitting 45 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65 / 66 Protectioncomplete All As Specified And Directed. 53 Supply Installng Testing And Commissioning Of Factory Made And Tested Cpri Approved Lt Panel Board, Indoor Type, Platform Mounted Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply , Having Bus Bar Chamber Wih Insulated Aluminium Bus Barsof 600 Ampinsulated On Porcelain Insulators.The Panel Shall Be Dust And Vermin Proof, Ip 54 Class Protection And Made Of2mm Crca Ms Sheetand 50 X 50X 6Mm Thick Angle Iron Frame Work, Powder Coated Finish Fronback Opening Type, With Aprons For Cable Entry From Bottom And Fixing 02 Nos Danger Notice Plate With Letter , Figures And Conventional Skul Bones In Signal Red Colour And Fixed Front & Back Door Lt Panel Etc With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Lockingarangement , Internal Wiring With Pvc Insulated, Stranded Copper Conductor, Frls Cable, Is-694 Marked Of Adequate Size But Not Less Than 2.5 Sqmm.The Platform Shall Be Such That Of Size 16 To 400 Sqmm And Compising Of The Following: ( For Transformer No-01 ( 200 Kva ) ( A ) Bus Bar Chamber Of 3 Phase Andneutral 4 Strip415 Volts With 600 Amps Aluminium - 1 Set ( A ) 3 Phase 4 Wire 50 Hz Mccb 4 Pole 415 V 400 Amps, 35 Ka -2 Nos. ( Incoming ) ( B ) Ammeter 0- 1000 Amps 96 Mm X 96Mm Electro Mechancial Type With Three Way On / Off Rotary Type Selector Switch And 3 Current Transformer Of Suitable Ratio And Capacity Qty 1 No ( C ) Indicating Lamps For Three Phases Qty 1 Set Of 3 Nos 54 ( D ) Voltmeter 0 - 500 Volts 96 Mm X 96Mm Electro Mechanical Type With 3 Way On / Off Rotary Type Selector Switch - Qty 01 No Make Ae / Rishab / Meco / Enercon ) . Outgoing:- ( A ) 4 Pole Mccb 63 Amp 50 Hz 415 V, 25 Ka-1 No. ( B ) 4 Pole Mccb 160 Amp 50 Hz 415 V, 35 Ka - 01 No. ( C ) . 4 Pole Mccb 100 Amp 50 Hz 415 V, 35 Ka - 01 No ( D ) Tpn 40 Amp , 50 Hz 415 V, 35 Ka -01 No ( E ) . On Load Change Over Switch Of Capacity 400Amp - 1 No. ( F ) . Mccb 400 A, 36 Ka - 1 No. , Including Cost Of Material, Labour And T & P As Per Drawing Complete, For Proper Completion Of Workall As Specified And Directed.. ( D ) Platform Of Panel :- Platform For The Pane With Pcc 1:4:8 Type D2 With 40Mmgraded Crushed Stone , 15Cm Thick In Foundation, Brick Work In Cm 1:6 With Sub Class B Old Size Bricks, Rendering 15Cm Thicj In In Cm 1:6 On Exposed Surfaces And 100Mm Thick Pcc Padding 1:3:6 Type -1 Using 20Mm Graded Crushed Stone Aggregate On Toop And Grouting Bolts Etc For Panel Thethe Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel White Paint.The Platform Shall Be Such That It Is Of A Height 45 Cm Above The Nearest Road Level.Notes :- ( I ) All Termination Of Existing Cable Should Be Provided With Copper Lugs / Thimbles And Suitable Size Of Glands & Rate For The Same Is Deemed To Be Included In The Item ( Iii ) Provision Of One Spare Mccb And One Spare Mcb Chamber In Panel To Be Made For Future Extension. ( Iii ) The Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel Whitepaint. 55 Supply Installng Testing And Commissioning Factory Made And Tested Cpri Approved Lt Panel Board, Outdoor Type, Canopy Headed, Platform Mounted Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply , Having Bus Bar Chamber Wih Insulated Aluminium Bus Bars Of Cap 250 Ampinsulated On Porcelain Insulators.The Panel Shall Be Dust And Vermin Proof, Ip 65 Class Protection And Made Of 3.15Mm Crca Ms Sheetand 50 X 50X 6Mm Thick Angle Iron Frame Work, Powder Coated Finish Fronback Opening Type, With Aprons For Cable Entry From Bottom And Fixing 02 Nos Danger Notice Plate With Letter , Figures And Conventional Skul Bones In Signal Red Colour And Fixed Front & Back Door Lt Panel Etc With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Lockingarangement , Internal Wiring With Pvc Insulated, Stranded Copper Conductor, Frls Cable, Is-694 Marked Of Adequate Size But Not Less Than 2.5 Sqmm.The Platform Shall Be Such That Of Size 16 To 400 Sqmm And Compising Of The Following: ( Location E ) ( A ) Mccb 4 Pole 415 V 160 Amps.35 Ka Adjustable Type -2 No ( 01 Spare ) ( Incoming ) ( B ) Ammeter 0- 500 Amps 96 Mm X 96Mm Electro Mechancial Type With Three Way On / Off Rotary Type Selector Switch And 3 Current Transformer Of Suitable Ratio And Capacity Qty 1 No ( C ) Indicating Lamps For Three Phases Qty 1 Set Of 3 Nos ( D ) Voltmeter 0 - 500 Volts 96 Mm X 96Mm Electro Mechanical Type With 3 Way On / Off Rotary Type Selector Switch - Qty 01 No Make Ae / Rishab / Meco / Enercon ) . 56 Outgoing:- ( A ) 4 Pole Mccb 63 Amp, 50 Hz 415 V-02 Nos. ( B ) . 4 Pole Mccb 40 Amp, 50 Hz 415 V-01 No. ( C ) Tpn 40 Amp , 50 Hz 415 V -01 No , Including Cost Of Material, Labour And T & P As Per Drawing Complete, For Proper Completion Of Work All As Specified And Directed. ( D ) Platform Of Panel :- Platform For The Pane With Pcc 1:4:8 Type D2 With 40Mmgraded Crushed Stone , 15Cm Thick In Foundation, Brick Work In Cm 1:6 With Sub Class B Old Size Bricks, Rendering 15Cm Thicj In In Cm 1:6 On Exposed Surfaces And 100Mm Thick Pcc Padding 1:3: 6 Type -1 Using 20Mm Graded Crushed Stone Aggregate On Toop And Grouting Bolts Etc For Panel Thethe Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel White Paint.The Platform Shall Be Such That It Is Of A Height 45 Cm Above The Nearest Road Level.Notes :- Ote : ( I ) All Termination Of Existing Cable Should Be Provided With Copper Lugs / Thimbles And Suitable Size Of Glands & Rate For The Same Is Deemed To Be Included In The Item ( Iii ) Provision Of One Spare Mccb And One Spare Mcb Chamber In Panel To Be Made For Future Extension. ( Iii ) The Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel Whitepaint. 57 Supply Installng Testing And Commissioning Factory Made And Tested Cpri Approved Lt Panel Board, Outdoor Type, Canopy Headed, Platform Mounted Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply , Having Bus Bar Chamber Wih Insulated Aluminium Bus Bars Of Cap 100 Ampinsulated On Porcelain Insulators.The Panel Shall Be Dust And Vermin Proof, Ip 65 Class Protection And Made Of 3.15Mm Crca Ms Sheetand 50 X 50X 6Mm Thick Angle Iron Frame Work, Powder Coated Finish Fronback Opening Type, With Aprons For Cable Entry From Bottom And Fixing 02 Nos Danger Notice Plate With Letter , Figures And Conventional Skul Bones In Signal Red Colour And Fixed Front & Back Door Lt Panel Etc With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Lockingarangement , Internal Wiring With Pvc Insulated, Stranded Copper Conductor, Frls Cable, Is-694 Marked Of Adequate Size But Not Less Than 2.5 Sqmm.The Platform Shall Be Such That Of Size 16 To 400 Sqmm And Compising Of The Following: ( Location C ) ( A ) Mccb 4 Pole 415 V 63 Amps, 25 Ka -2 Nos ( 1 Spare ) ( Incoming ) ( B ) Ammeter 0- 500 Amps 96 Mm X 96Mm Electro Mechancial Type With Three Way On / Off Rotary Type Selector Switch And 3 Current Transformer Of Suitable Ratio And Capacity Qty 1 No ( C ) Indicating Lamps For Three Phases Qty 1 Set Of 3 Nos ( D ) Voltmeter 0 - 500 Volts 96 Mm X 96Mm Electro Mechanical Type With 3 Way On / Off Rotary Type Selector Switch - Qty 01 No Make Ae / Rishab / Meco / Enercon ) . 58 Outgoing:-A ) 4 Pole Mccb 40 Amp, 50 Hz 415 V, 25 Ka -02 Nos, Including Cost Of Material, Labour And T & P As Per Drawing Complete, For Proper Completion Of Work And As Per Direction Of Engineer In Charge. ( D ) Platform Of Panel :- Platform For The Pane With Pcc 1:4:8 Type D2 With 40Mmgraded Crushed Stone , 15Cm Thick In Foundation, Brick Work In Cm 1:6 With Sub Class B Old Size Bricks, Rendering 15Cm Thicj In In Cm 1:6 On Exposed Surfaces And 100Mm Thick Pcc Padding 1:3:6 Type -1 Using 20Mm Graded Crushed Stone Aggregate On Toop And Grouting Bolts Etc For Panel Thethe Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel White Paint.The Platform Shall Be Such That It Is Of A Height 45 Cm Above The Nearest Road Level.Notes :- ( I ) All Termination Of Existing Cable Should Be Provided With Copper Lugs / Thimbles And Suitable Size Of Glands & Rate For The Same Is Deemed To Be Included In The Item ( Iii ) Provision Of One Spare Mccb And One Spare Mcb Chamber In Panel To Be Made For Future Extension. ( Iii ) The Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel Whitepaint. 59 Supply Installng Testing And Commissioning Of Factory Made And Tested Cpri Approved Lt Panel Board, Indooor Type, Platform Mounted Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply , Having Bus Bar Chamber Wih Insulated Aluminium Bus Barsof 1200 Ampinsulated On Porcelain Insulators.The Panel Shall Be Dust And Vermin Proof, Ip 54 Class Protection And Made Of 2Mm Crca Ms Sheetand 50 X 50X 6Mm Thick Angle Iron Frame Work, Powder Coated Finish Fronback Opening Type, With Aprons For Cable Entry From Bottom And Fixing 02 Nos Danger Notice Plate With Letter , Figures And Conventional Skul Bones In Signal Red Colour And Fixed Front & Back Door Lt Panel Etc With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Lockingarangement , Internal Wiring With Pvc Insulated, Stranded Copper Conductor, Frls Cable, Is-694 Marked Of Adequate Size But Not Less Than 2.5 Sqmm.The Platform Shall Be Such That Of Size 16 To 400 Sqmm And Compising Of The Following: ( For Transformer No-02 ( 315 Kva ) ( A ) Bus Bar Chamber Of 3 Phase Andneutral 4 Strip415 Volts With 1200 Amps Aluminium - 1 Set ( A ) 3 Phase 4 Wire 50 Hz Acb4 Pole 415 V 800 Amps, 50 Ka -1 Nos. ( Incoming ) ( B ) Ammeter 0- 1000 Amps 96 Mm X 96Mm Electro Mechancial Type With Three Way On / Off Rotary Type Selector Switch And 3 Current Transformer Of Suitable Ratio And Capacity Qty 1 No ( C ) Indicating Lamps For Three Phases Qty 1 Set Of 3 Nos 60 ( D ) Voltmeter 0 - 500 Volts 96 Mm X 96Mm Electro Mechanical Type With 3 Way On / Off Rotary Type Selector Switch - Qty 01 No Make Ae / Rishab / Meco / Enercon ) . Outgoing:- ( A ) 4 Pole Mccb 63 Amp, 50 Hz 415 V, 25 Ka-1 No. ( B ) 4 Pole Mccb 160 Amp 50 Hz 415 V, 35 Ka - 01 No ( E ) . 4 Pole Mccb 125 Amp 50 Hz 415 V, 35 Ka - 01 No. ( D ) . 4 Pole Mccb 100 Amp 50 Hz 415 V, 35 Ka - 01 No. ( F ) 4 Pole Mccb 40 Amp, 50 Hz 415 V, 25 Ka-2 Nos. ( G ) Tpn 40 Amp , 50 Hz 415 V , 25 Ka-01 No ( H ) . On Load Change Over Switch Of Capacity 400Amp - 1 No. ( J ) 3 Phase 4 Wire 50 Hz 400 Amp Mccb, 35 Ka -01 ( For Ring Main ) , Including Cost Of Material, Labour And T & P As Per Drawing Complete, For Proper Completion Of Work And As Per Direction Of Engineer In Charge. ( K ) Platform Of Panel :- Platform For The Pane With Pcc 1:4:8 Type D2 With 40Mmgraded Crushed Stone , 15Cm Thick In Foundation, Brick Work In Cm 1:6 With Sub Class B Old Size Bricks, Rendering 15Cm Thicj In In Cm 1:6 On Exposed Surfaces And 100Mm Thick Pcc Padding 1:3:6 Type -1 Using 20Mm Graded Crushed Stone Aggregate On Toop And Grouting Bolts Etc For Panel Thethe Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel White Paint.The Platform Shall Be Such That It Is Of A Height 45 Cm Above The Nearest Road Level.Notes : ( I ) All Termination Of Existing Cable Should Be Provided With Copper Lugs / Thimbles And Suitable Size Of Glands & Rate For The Same Is Deemed To Be Included In The Item. ( Iii ) Provision Of One Spare Mccb And One Spare Mcb Chamber In Panel To Be Made For Future Extension. ( Iii ) The Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel Whitepaint. 61 Supply Installng Testing And Commissioning Of Factory Made And Tested Cpri Approved Lt Panel Board, Outdoor Type, Canopy Headed, Platform Mounted Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply , Having Bus Bar Chamber Wih Insulated Aluminium Bus Bars Of Cap 250 Ampinsulated On Porcelain Insulators.The Panel Shall Be Dust And Vermin Proof, Ip 65 Class Protection And Made Of 3.15Mm Crca Ms Sheetand 50 X 50X 6Mm Thick Angle Iron Frame Work, Powder Coated Finish Fronback Opening Type, With Aprons For Cable Entry From Bottom And Fixing 02 Nos Danger Notice Plate With Letter , Figures And Conventional Skul Bones In Signal Red Colour And Fixed Front & Back Door Lt Panel Etc With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Lockingarangement , Internal Wiring With Pvc Insulated, Stranded Copper Conductor, Frls Cable, Is-694 Marked Of Adequate Size But Not Less Than 2.5 Sqmm.The Platform Shall Be Such That Of Size 16 To 400 Sqmm And Compising Of The Following: ( Location K ) ( A ) Mccb 4 Pole 415 V 160 Amps, 35 Ka-2 Nos ( 1 Spare ) ( Incoming ) ( B ) Ammeter 0- 500 Amps 96 Mm X 96Mm Electro Mechancial Type With Three Way On / Off Rotary Type Selector Switch And 3 Current Transformer Of Suitable Ratio And Capacity Qty 1 No ( C ) Indicating Lamps For Three Phases Qty 1 Set Of 3 Nos ( D ) Voltmeter 0 - 500 Volts 96 Mm X 96Mm Electro Mechanical Type With 3 Way On / Off Rotary Type Selector Switch - Qty 01 No Make Ae / Rishab / Meco / Enercon ) . 62 Outgoing:-A ) 4 Pole Mccb 63 Amp , 50 Hz 415 V, 25 Ka -03 Nos, ( E ) Platform Of Panel :- Platform For The Pane With Pcc 1:4:8 Type D2 With 40Mmgraded Crushed Stone , 15Cm Thick In Foundation, Brick Work In Cm 1:6 With Sub Class B Old Size Bricks, Rendering 15Cm Thick In In Cm 1:6 On Exposed Surfaces And 100Mm Thick Pcc Padding 1:3:6 Type -1 Using 20Mm Graded Crushed Stone Aggregate On Toop And Grouting Bolts Etc For Panel Thethe Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel White Paint.The Platform Shall Be Such That It Is Of A Height 45 Cm Above The Nearest Road Level.Notes :- ( I ) All Termination Of Existing Cable Should Be Provided With Copper Lugs / Thimbles And Suitable Size Of Glands & Rate For The Same Is Deemed To Be Included In The Item ( Iii ) Provision Of One Spare Mccb And One Spare Mcb Chamber In Panel To Be Made For Future Extension. ( Iii ) The Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel Whitepaint. 63 Supply Installng Testing And Commissioning Of Factory Made And Tested Cpri Approved Lt Panel Board, Outdoor Type, Canopy Headed, Platform Mounted Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply , Having Bus Bar Chamber Wih Insulated Aluminium Bus Bars Of Cap 200 Ampinsulated On Porcelain Insulators.The Panel Shall Be Dust And Vermin Proof, Ip 65 Class Protection And Made Of 3.15Mm Crca Ms Sheetand 50 X 50X 6Mm Thick Angle Iron Frame Work, Powder Coated Finish Fronback Opening Type, With Aprons For Cable Entry From Bottom And Fixing 02 Nos Danger Notice Plate With Letter , Figures And Conventional Skul Bones In Signal Red Colour And Fixed Front & Back Door Lt Panel Etc With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Lockingarangement , Internal Wiring With Pvc Insulated, Stranded Copper Conductor, Frls Cable, Is-694 Marked Of Adequate Size But Not Less Than 2.5 Sqmm.The Platform Shall Be Such That Of Size 16 To 400 Sqmm And Compising Of The Following: ( Location L ) ( A ) Mccb 4 Pole 415 V 125 Amps, 35 Ka-2 Nos ( 1 Spare ) ( Incoming ) ( B ) Ammeter 0- 500 Amps 96 Mm X 96Mm Electro Mechancial Type With Three Way On / Off Rotary Type Selector Switch And 3 Current Transformer Of Suitable Ratio And Capacity Qty 1 No ( C ) Indicating Lamps For Three Phases Qty 1 Set Of 3 Nos ( D ) Voltmeter 0 - 500 Volts 96 Mm X 96Mm Electro Mechanical Type With 3 Way On / Off Rotary Type Selector Switch - Qty 01 No Make Ae / Rishab / Meco / Enercon ) . 64 Outgoing:- ( A ) 4 Pole Mccb 63 Amp , 50 Hz 415 V, 25 Ka -02 Nos, ( B ) Platform Of Panel :- Platform For The Pane With Pcc 1:4:8 Type D2 With 40Mmgraded Crushed Stone , 15Cm Thick In Foundation, Brick Work In Cm 1:6 With Sub Class B Old Size Bricks, Rendering 15Cm Thicj In In Cm 1:6 On Exposed Surfaces And 100Mm Thick Pcc Padding 1:3:6 Type -1 Using 20Mm Graded Crushed Stone Aggregate On Toop And Grouting Bolts Etc For Panel Thethe Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel White Paint.The Platform Shall Be Such That It Is Of A Height 45 Cm Above The Nearest Road Level.Notes :- ( I ) All Termination Of Existing Cable Should Be Provided With Copper Lugs / Thimbles And Suitable Size Of Glands & Rate For The Same Is Deemed To Be Included In The Item ( Iii ) Provision Of One Spare Mccb And One Spare Mcb Chamber In Panel To Be Made For Future Extension. ( Iii ) The Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel Whitepaint. 65 Supply Installng Testing And Commissioning Of Factory Made And Tested Cpri Approved Lt Panel Board, Outdoor Type, Canopy Headed, Platform Mounted Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply , Having Bus Bar Chamber Wih Insulated Aluminium Bus Bars Of Cap 160 Ampinsulated On Porcelain Insulators.The Panel Shall Be Dust And Vermin Proof, Ip 65 Class Protection And Made Of 3.15Mm Crca Ms Sheetand 50 X 50X 6Mm Thick Angle Iron Frame Work, Powder Coated Finish Fronback Opening Type, With Aprons For Cable Entry From Bottom And Fixing 02 Nos Danger Notice Plate With Letter , Figures And Conventional Skul Bones In Signal Red Colour And Fixed Front & Back Door Lt Panel Etc With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Lockingarangement , Internal Wiring With Pvc Insulated, Stranded Copper Conductor, Frls Cable, Is-694 Marked Of Adequate Size But Not Less Than 2.5 Sqmm.The Platform Shall Be Such That Of Size 16 To 400 Sqmm And Compising Of The Following: ( Location P ) ( A ) Mccb 4 Pole 415 V 100 Amps, 25 Ka-2 Nos ( 1 Spare ) ( Incoming ) ( B ) Ammeter 0- 500 Amps 96 Mm X 96Mm Electro Mechancial Type With Three Way On / Off Rotary Type Selector Switch And 3 Current Transformer Of Suitable Ratio And Capacity Qty 1 No ( C ) Indicating Lamps For Three Phases Qty 1 Set Of 3 Nos ( D ) Voltmeter 0 - 500 Volts 96 Mm X 96Mm Electro Mechanical Type With 3 Way On / Off Rotary Type Selector Switch - Qty 01 No Make Ae / Rishab / Meco / Enercon ) . 66 Outgoing:-A ) 4 Pole Mccb 63 Amp, 50 Hz 415 V, 25 Ka -02 Nos, ( E ) Platform Of Panel :- Platform For The Pane With Pcc 1:4:8 Type D2 With 40Mmgraded Crushed Stone , 15Cm Thick In Foundation, Brick Work In Cm 1:6 With Sub Class B Old Size Bricks, Rendering 15Cm Thicj In In Cm 1:6 On Exposed Surfaces And 100Mm Thick Pcc Padding 1:3:6 Type -1 Using 20Mm Graded Crushed Stone Aggregate On Toop And Grouting Bolts Etc For Panel Thethe Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel White Paint.The Platform Shall Be Such That It Is Of A Height 45 Cm Above The Nearest Road Level.Notes :- Ote : ( I ) All Termination Of Existing Cable Should Be Provided With Copper Lugs / Thimbles And Suitable Size Of Glands & Rate For The Same Is Deemed To Be Included In The Item ( Iii ) Provision Of One Spare Mccb And One Spare Mcb Chamber In Panel To Be Made For Future Extension. ( Iii ) The Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel Whitepaint. 67 Supply Installng Testing And Commissioning Of Factory Made And Tested Cpri Approved Lt Panel Board, Indoor Type, Platform Mounted Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply , Having Bus Bar Chamber Wih Insulated Aluminium Bus Barsof 100 Ampinsulated On Porcelain Insulators.The Panel Shall Be Dust And Vermin Proof, Ip 54 Class Protection And Made Of 2Mm Crca Ms Sheetand 50 X 50X 6Mm Thick Angle Iron Frame Work, Powder Coated Finish Fronback Opening Type, With Aprons For Cable Entry From Bottom And Fixing 02 Nos Danger Notice Plate With Letter , Figures And Conventional Skul Bones In Signal Red Colour And Fixed Front & Back Door Lt Panel Etc With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Lockingarangement , Internal Wiring With Pvc Insulated, Stranded Copper Conductor, Frls Cable, Is-694 Marked Of Adequate Size But Not Less Than 2.5 Sqmm.The Platform Shall Be Such That Of Size 16 To 400 Sqmm And Compising Of The Following: ( Lt Panel No- 08 , Raw Water Pump House ) ( A ) Bus Bar Chamber Of 3 Phase Andneutral 4 Strip415 Volts With 100 Amps Aluminium - 1 Set ( A ) 3 Phase 4 Wire 50 Hzmccb 4 Pole 415 V 63 Amps, 36 Ka -2 Nos. ( Incoming ) ( B ) Ammeter 0- 1000 Amps 96 Mm X 96Mm Electro Mechancial Type With Three Way On / Off Rotary Type Selector Switch And 3 Current Transformer Of Suitable Ratio And Capacity Qty 1 No ( C ) Indicating Lamps For Three Phases Qty 1 Set Of 3 Nos ( D ) Voltmeter 0 - 500 Volts 96 Mm X 96Mm Electro Mechanical Type With 3 Way On / Off Rotary Type Selector Switch - Qty 01 No Make Ae / Rishab / Meco / Enercon ) . 68 Outgoing:- ( A ) 4 Pole Mccb 63 Amp , 50 Hz 415, 25 Ka-03 Nos ( B ) Tpn Mcb 40A, 25 Ka - 1 No. ( C ) . Star Delta Starter For 10 Hp Motor - 2 Nos. ( D ) . Fully Automatic Star Delta Starter 30 Hpfor 20 Hp Motor - 1 Nos ( E ) Platform Of Panel :- Platform For The Pane With Pcc 1:4:8 Type D2 With 40Mmgraded Crushed Stone , 15Cm Thick In Foundation, Brick Work In Cm 1:6 With Sub Class B Old Size Bricks, Rendering 15Cm Thicj In In Cm 1:6 On Exposed Surfaces And 100Mm Thick Pcc Padding 1:3:6Type -1 Using 20Mm Graded Crushed Stone Aggregate On Toop And Grouting Bolts Etc For Panel Thethe Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel White Paint.The Platform Shall Be Such That It Is Of A Height 45 Cm Above The Nearest Road Level.Notes : ( I ) All Termination Of Existing Cable Should Be Provided With Copper Lugs / Thimbles And Suitable Size Of Glands & Rate For The Same Is Deemed To Be Included In The Item ( Iii ) Provision Of One Spare Mccb And One Spare Mcb Chamber In Panel To Be Made For Future Extension. ( Iii ) The Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel Whitepaint. 69 Supply Installng Testing And Commissioning Of Factory Made And Tested Cpri Approved Lt Panel Board, Indoor Type, Platform Mounted Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply , Having Bus Bar Chamber Wih Insulated Aluminium Bus Barsof 100 Ampinsulated On Porcelain Insulators.The Panel Shall Be Dust And Vermin Proof, Ip 54 Class Protection And Made Of 2Mm Crca Ms Sheetand 50 X 50X 6Mm Thick Angle Iron Frame Work, Powder Coated Finish Fronback Opening Type, With Aprons For Cable Entry From Bottom And Fixing 02 Nos Danger Notice Plate With Letter , Figures And Conventional Skul Bones In Signal Red Colour And Fixed Front & Back Door Lt Panel Etc With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Lockingarangement , Internal Wiring With Pvc Insulated, Stranded Copper Conductor, Frls Cable, Is-694 Marked Of Adequate Size But Not Less Than 2.5 Sqmm.The Platform Shall Be Such That Of Size 16 To 400 Sqmm And Compising Of The Following: ( Lt Panel No- 09 , Clean Water Pump House ) ( A ) Bus Bar Chamber Of 3 Phase Andneutral 4 Strip415 Volts With 100 Amps Aluminium - 1 Set ( A ) 3 Phase 4 Wire 50 Hzmccb 4 Pole 415 V 63 Amps, 25 Ka -2 Nos. ( Incoming ) ( B ) Ammeter 0- 1000 Amps 96 Mm X 96Mm Electro Mechancial Type With Three Way On / Off Rotary Type Selector Switch And 3 Current Transformer Of Suitable Ratio And Capacity Qty 1 No ( C ) Indicating Lamps For Three Phases Qty 1 Set Of 3 Nos ( D ) Voltmeter 0 - 500 Volts 96 Mm X 96Mm Electro Mechanical Type With 3 Way On / Off Rotary Type Selector Switch - Qty 01 No Make Ae / Rishab / Meco / Enercon ) . 70 Outgoing:- ( A ) 4 Pole Mccb 63 Amp , 50 Hz 415V, 25 Ka-02 Nos ( B ) Tpn Mcb 40A, 25 Ka - 1 No. ( C ) . Star Delta Starter For 10 Hp Motor - 2 Nos, ( D ) Platform Of Panel :- Platform For The Pane With Pcc 1:4:8 Type D2 With 40Mmgraded Crushed Stone , 15Cm Thick In Foundation, Brick Work In Cm 1:6 With Sub Class B Old Size Bricks, Rendering 15Cm Thicj In In Cm 1:6 On Exposed Surfaces And 100Mm Thick Pcc Padding 1:3:6Type -1 Using 20Mm Graded Crushed Stone Aggregate On Toop And Grouting Bolts Etc For Panel Thethe Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel White Paint.The Platform Shall Be Such That It Is Of A Height 45 Cm Above The Nearest Road Level.Notes :- Ote : ( I ) All Termination Of Existing Cable Should Be Provided With Copper Lugs / Thimbles And Suitable Size Of Glands & Rate For The Same Is Deemed To Be Included In The Item ( Iii ) Provision Of One Spare Mccb And One Spare Mcb Chamber In Panel To Be Made For Future Extension. ( Iii ) The Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel Whitepaint. 71 Supply Installng Testing And Commissioning Of Factory Made And Tested Cpri Approved Lt Panel Board, Outdoor Type, Canopy Headed, Platform Mounted Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply , Having Bus Bar Chamber Wih Insulated Aluminium Bus Bars Of Cap 63 Ampinsulated On Porcelain Insulators.The Panel Shall Be Dust And Vermin Proof, Ip 65 Class Protection And Made Of 3.15Mm Crca Ms Sheetand 50 X 50X 6Mm Thick Angle Iron Frame Work, Powder Coated Finish Fronback Opening Type, With Aprons For Cable Entry From Bottom And Fixing 02 Nos Danger Notice Plate With Letter , Figures And Conventional Skul Bones In Signal Red Colour And Fixed Front & Back Door Lt Panel Etc With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Lockingarangement , Internal Wiring With Pvc Insulated, Stranded Copper Conductor, Frls Cable, Is-694 Marked Of Adequate Size But Not Less Than 2.5 Sqmm.The Platform Shall Be Such That Of Size 16 To 400 Sqmm And Compising Of The Following: ( Panel 10 For Street Light ) ( A ) Mccb 4 Pole 415 V 32 Amps, 25 Ka- Nos ( Incoming ) ( B ) Ammeter 0- 500 Amps 96 Mm X 96Mm Electro Mechancial Type With Three Way On / Off Rotary Type Selector Switch And 3 Current Transformer Of Suitable Ratio And Capacity Qty 1 No ( C ) Indicating Lamps For Three Phases Qty 1 Set Of 3 Nos ( D ) Voltmeter 0 - 500 Volts 96 Mm X 96Mm Electro Mechanical Type With 3 Way On / Off Rotary Type Selector Switch - Qty 01 No Make Ae / Rishab / Meco / Enercon ) . 72 Outgoing:- ( A ) 4 Pole Mccb 32 Amp , 50 Hz 415 V, 25 Ka -03 No ( B ) . Timer Switch, Controlled Relay, Contactors Etc, ( C ) Platform Of Panel :- Platform For The Pane With Pcc 1:4:8 Type D2 With 40Mmgraded Crushed Stone , 15Cm Thick In Foundation, Brick Work In Cm 1:6 With Sub Class B Old Size Bricks, Rendering 15Cm Thicj In In Cm 1:6 On Exposed Surfaces And 100Mm Thick Pcc Padding 1:3:6 Type -1 Using 20Mm Graded Crushed Stone Aggregate On Toop And Grouting Bolts Etc For Panel Thethe Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel White Paint.The Platform Shall Be Such That It Is Of A Height 45 Cm Above The Nearest Road Level.Notes :- Ote : ( I ) All Termination Of Existing Cable Should Be Provided With Copper Lugs / Thimbles And Suitable Size Of Glands & Rate For The Same Is Deemed To Be Included In The Item ( Iii ) Provision Of One Spare Mccb And One Spare Mcb Chamber In Panel To Be Made For Future Extension. ( Iii ) The Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel Whitepaint. 73 Supply Installng Testing And Commissioning Of Factory Made And Tested Cpri Approved Lt Panel Board, Outdoor Type, Canopy Headed, Platform Mounted Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply , Having Bus Bar Chamber Wih Insulated Aluminium Bus Bars Of Cap 160 Ampinsulated On Porcelain Insulators.The Panel Shall Be Dust And Vermin Proof, Ip 65 Class Protection And Made Of 3.15Mm Crca Ms Sheetand 50 X 50X 6Mm Thick Angle Iron Frame Work, Powder Coated Finish Fronback Opening Type, With Aprons For Cable Entry From Bottom And Fixing 02 Nos Danger Notice Plate With Letter , Figures And Conventional Skul Bones In Signal Red Colour And Fixed Front & Back Door Lt Panel Etc With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Lockingarangement , Internal Wiring With Pvc Insulated, Stranded Copper Conductor, Frls Cable, Is-694 Marked Of Adequate Size But Not Less Than 2.5 Sqmm.The Platform Shall Be Such That Of Size 16 To 400 Sqmm And Compising Of The Following: ( Panel B ) ( A ) Mccb 4 Pole 415 V 100 Amps, 25 Ka-2Nos ( 01 Spares ) ( Incoming ) ( B ) Ammeter 0- 500 Amps 96 Mm X 96Mm Electro Mechancial Type With Three Way On / Off Rotary Type Selector Switch And 3 Current Transformer Of Suitable Ratio And Capacity Qty 1 No ( C ) Indicating Lamps For Three Phases Qty 1 Set Of 3 Nos ( D ) Voltmeter 0 - 500 Volts 96 Mm X 96Mm Electro Mechanical Type With 3 Way On / Off Rotary Type Selector Switch - Qty 01 No Make Ae / Rishab / Meco / Enercon ) . 74 Outgoing- ( A ) 4 Pole Mccb Upto 40 Amp 50 Hz 415 V, 25 Ka-3 Nos., ( B ) Platform Of Panel :- Platform For The Pane With Pcc 1:4:8 Type D2 With 40Mmgraded Crushed Stone , 15Cm Thick In Foundation, Brick Work In Cm 1:6 With Sub Class B Old Size Bricks, Rendering 15Cm Thicj In In Cm 1:6 On Exposed Surfaces And 100Mm Thick Pcc Padding 1:3:6Type -1 ( Using 20Mm Graded Stone Aggregate ) On Toop And Grouting Bolts Etc For Panel Thethe Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel White Paint.The Platform Shall Be Such That It Is Of A Height 45 Cm Above The Nearest Road Level.Notes :- ( I ) All Termination Of Existing Cable Should Be Provided With Copper Lugs / Thimbles And Suitable Size Of Glands & Rate For The Same Is Deemed To Be Included In The Item ( Iii ) Provision Of One Spare Mccb And One Spare Mcb Chamber In Panel To Be Made For Future Extension. ( Iii ) The Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel Whitepaint. 75 Supply Installng Testing And Commissioning Of Factory Made And Tested Cpri Approved Lt Panel Board, Outdoor Type, Canopy Headed, Platform Mounted Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply , Having Bus Bar Chamber Wih Insulated Aluminium Bus Bars Of Cap 160 Ampinsulated On Porcelain Insulators.The Panel Shall Be Dust And Vermin Proof, Ip 65 Class Protection And Made Of 3.15Mm Crca Ms Sheetand 50 X 50X 6Mm Thick Angle Iron Frame Work, Powder Coated Finish Fronback Opening Type, With Aprons For Cable Entry From Bottom And Fixing 02 Nos Danger Notice Plate With Letter , Figures And Conventional Skul Bones In Signal Red Colour And Fixed Front & Back Door Lt Panel Etc With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Lockingarangement , Internal Wiring With Pvc Insulated, Stranded Copper Conductor, Frls Cable, Is-694 Marked Of Adequate Size But Not Less Than 2.5 Sqmm.The Platform Shall Be Such That Of Size 16 To 400 Sqmm And Compising Of The Following: ( Panel S ) ( A ) Mccb 4 Pole 415 V 63 Amps, 25 Ka- 2 Nos ( 01 Spare ( Incoming ) ( B ) Ammeter 0- 500 Amps 96 Mm X 96Mm Electro Mechancial Type With Three Way On / Off Rotary Type Selector Switch And 3 Current Transformer Of Suitable Ratio And Capacity Qty 1 No ( C ) Indicating Lamps For Three Phases Qty 1 Set Of 3 Nos ( D ) Voltmeter 0 - 500 Volts 96 Mm X 96Mm Electro Mechanical Type With 3 Way On / Off Rotary Type Selector Switch - Qty 01 No Make Ae / Rishab / Meco / Enercon ) . 76 Outgoing- ( A ) 4 Pole Mccb Upto 63 Amp 50 Hz 415 V, 25 Ka-1 Nos., ( B ) Tpn Mcb 40 Amp-01 No ( E ) Platform Of Panel :- Platform For The Pane With Pcc 1:4:8 Type D2 With 40Mmgraded Crushed Stone , 15Cm Thick In Foundation, Brick Work In Cm 1:6 With Sub Class B Old Size Bricks, Rendering 15Cm Thick In In Cm 1:6 On Exposed Surfaces And 100Mm Thick Pcc Padding 1:3:6 Type -1 ( Using 20Mm Graded Stone Aggregate ) On Top And Grouting Bolts Etc For Panel Thethe Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel White Paint.The Platform Shall Be Such That It Is Of A Height 45 Cm Above The Nearest Road Level.Notes :- ( I ) All Termination Of Existing Cable Should Be Provided With Copper Lugs / Thimbles And Suitable Size Of Glands & Rate For The Same Is Deemed To Be Included In The Item ( Iii ) Provision Of One Spare Mccb And One Spare Mcb Chamber In Panel To Be Made For Future Extension. ( Iii ) The Various Feeders Shall Be Indicated By 50Mm Size Letters In Synthetic Enamel Whitepaint. 77 Supply And Fixing Of Metal Juctionbox Ofsuitable Size With Aluminium Bus Bar Rated For 415 V , 50 Hz, Ac Supply With10 Amp, Sp Mcb For Controlling Of Street Light, For Proper Completion Of Workcomplete All As Specified And Directed. 78 Supply And Fixing Cable Route Indicator Made Out Pcc Pole ( 0.3M X 0.3M X 1.0M ) ( Lxwxh ) On H T / Lt Cable Upto 1Mtr Depth Grouted Inthe Ground With Sutaible Pcc Work With Writing Lt / Ht Cable / Jointwith Pole Number Complete All As Specified And Directed. 79 External Water Supply 80 Materials And Labour For Centrifugally Cast ( Spun ) Ductile Iron Pressure Pipes For Water Mains, With Spigot And Socketed Ends, Class K9, Isi Marked [ Is 8329:2000 ( Re Affirmed 2005 ) ] , In Any Length, Jointed By Push-On Flexible Joints With Rubber Gaskets Conforming To Is 5382, Laid In Trenches, Complete All As Specified And Directed. Of Following Size:- ( For Distribution Main ) 81 ( A ) 200 Mm Dia. 82 ( B ) 150 Mm Dia. 83 ( C ) 100 Mm Dia. 84 M & L For Construction Of Valve Chamber For Gate / Sluice Valve Offollowing Size All As Specifiedincluding Necessary Excavation And Earthwork, Ms Sheet Cover And Angle Iron Frame, Painting With Two Coats Of Synthetic Enamel Paint Over A Coat Of Redoxide Zinc Chrome Primer Including Necessary Locking Arrangement Of Following Sizes Complete All As Specified And Directed. 85 ( A ) 1.2M X 1.2M X 1.2 M 86 B ) 0.9M X 0..9M X 0.9 M 87 ( C ) 0.75M X 0.75M X 0.75M 88 Materials And Labour For, 100 Mm Bore, Centrifugally Cast ( Spun ) Ductile Iron Pressure Pipes For Water Mains, With Spigot And Socketed Ends, Class K7, Isi Marked [ Is 8329:2000 ( Reaffirmed 2005 ) ] , In Any Length, Jointed By Push-On Flexible Joints With Rubber Gaskets Conforming To Is 5382, Laid In Trenches, Complete All As Specified And Directed. 89 Supply And Laying Ductile Iron Fittings For Spigot And Socketedpipes Such As Bends ( Any Type, Radius And Angle ) Tapers Any Type, ( Straight, Bend, Increasing, Decreasing Or Double Socket Etc. ) Tee Pieces Single Branch. Y Junction, Double Branch, Cross ( All Sockets Or Socket And Spigot ) Collars, Caps And Plugs, Isi Marked [ Is 9523 :2000 ( Re-Affirmed 2005 ) ] , Suitable For Bore Of Pipe Up To 450 Mm, Complete All As Specified And Directed. 90 S & F Valve Reflux With By Pass Arrangements Supplied And Installed Complete Of Size 100 Mm Dia, Complete All As Specified And Directed. 91 M & L For Drilling Trial Bore Of Suitable Diameter With Reverse Rotary Circulation Or Direct Circulation Method Or Combination Of Both By Using Power Rig For Housing B345:D348of 250 Mm Nominal Bore Reduced To 150 Mm Below Ground Level In Any Kind Of Soil Strata Including Hard Stone / Boulder Etc. Complete All As Specified And Directed. ( 100 Mtrx 02 Borewell As Different Location ) Complete All As Specified And Directed. Note:- The Anticipated Depth Of Boring Of The Tube Well At Site Is 100 Metres Below Ground Level. However, The Depth Of Boring May Be Varied Maximum Upto 40 Metres ( Plus Or Minus ) As Ordered By Pm In Writing. 92 M & L For Development Of Trial Bore By Reaming In Steps Viz From 250 Mm To 350 Mm ; From 350 Mm To 450 Mm ; From 450 Mm To 525 Mm; From 525 Mm To 675 Mm, Up To 60 Rm From Ground Level For Insertion Of Casing Pipe 350 Mm Bore For 02 Nos Borewell Complete All As Specified And Directed. 93 Development Of Trial Bore By Reaming In Steps Viz From 250 Mm To 350 Mm ; From 350 Mm To 450 Mm ; From 450 Mm To 525 Mm, Exceeding 60 Rm But Not Exceeding 100 Rm From Ground Level For Insertion Of Casing Pipe / Stainer, 250 Mm Bore, Complete All As Specified And Directed.Notes: - ( A ) Depending Upon The Availability Of Water Bearing Strata, If Drilling Beyond 100.00 Metre Is Required, The Same Shall Be Carried Out Only After Obtaining Written Approval From Pm. 94 Supply, Lowering And Fixing In Position 250 Mm Nominal Bore Erw Heavy Duty Ms Casing Pipe Of 7.10 Mm Wall Thickness And Welding Joints With Ms Coupler Ring Around The Pipes With Ms Flat Iron 80 Mm X 6 Mm Complete All As Specified And Directed. 95 Supply, Lowering And Fixing In Position 350Mm Nominal Bore Erw Heavy Duty Ms Casing Pipe Of 7.10 Mm Wall Thickness And Welding Joints With Ms Coupler Ring Around The Pipes With Ms Flat Iron 80 Mm X 6 Mm Complete All As Specified And Directed. 96 Supply Lowering And Fixing In Position 250 Mm Bore, 8.00 Mm Wall Thickness, Low Carbon Galvanized Steel ( Lcg ) Strainer, V Wired Type ( Inwardly Widening To Give No Clogging Property And Shall Have Minimum Geometrical Resistance To Water Flow To Reduce Frictional Head Losses ) , With 1 Mm Continuous Slot To Offer Not Less Than 25 % Open Area, And With Bevelled End, Conforming To Is 8110:2000 ( Reaffirmed 2006 ) , Butt Jointed By Welding In Suitable Length With Ms Flat Iron 80 X 6 Mm Coupler Ring All Around The Pipe Complete All As Specified And Directed. 97 Supply Lowering And Fixing In Position Ms Reducing Socket 350 Mm X 250 Mm Nominal Bore, 8 Mm Thick And Duly Welded To Pipe With Ms Flat Iron 80 Mm X 6 Mm Coupler Ring Complete All As Specified And Directed. 98 S & F Development Of Tube Well With Compressed Air And After With 25% Extra Capacity Pump By Pumping Muddy Water, Including Cost Of Material, Labour And T & P As Per Drawing Complete, All As Specified And Directed. 99 Supply And Fix, Bail Plug Having 3.00 Metre Length, Fabricated Out Of Erw Heavy Duty Ms Casing Pipe Of 7.10 Mm Wall Thickness And Suitable For 250 Mm Bore, Including Welding Joints With Ms Coupler Ring Around The Pipes With Ms Flat Iron 80 Mm X 6 Mm, Complete All As Specified And Directed. 100 Supplying, Pouring And Packing Pea-Gravel Of Size 3 Mm To 8 Mm And Packed All Around The Entire Bore Well To Fill In The Annular Space Between Pipe Assembly And Bore Hole, Complete All As Specified And Directed. 101 Providing Water Logging Test With Electro Logging Equipment And Required Machinery For Ascertaining / Logging Aquifers Encountered In Trial Bore And Arranging And Defining The Water Availability Test Giving Test Report Of Geo-Hydrologist From Govt. Approved Laboratory Recommending Water Bearing Zones, Tds Of Water Etc., Complete All As Specified And Directed. 102 M & L For Yield Test For Bore Well By Continuous Pumping For 15 Hrs To Determine Safe Pumping Yieldcomplete All As Specified And Directed. 103 Supply, Fixing And Lowering 100 Mm Bore Ms, Column Pipe, Both End Flanged, 3.00 Metre Long, Fitted With Flanges At Both Ends Made Out Of Heavy Grade Pipes Of 5.4 Mm Wall Thickness, Isi Marked ( Is: 1239-Part-I ) , Complete With Bolts, Nuts, Gaskets Etc. As Required Complete All As Specified And Directed. 104 Supply And Fixing Well Cap Made Out Of 5 Mm Thick Ms Plate With Provision Of Suitable Holes For Passing Through Two Runs Of Flat Three Core, Pvc Insulated Industrial Cable For Submersible Motor, 16.00 Sq. Mm And Suitable For Fixing To 350 Mm Nominal Bore Erw Heavy Duty Ms Casing Pipe Of 8.00 Mm Wall Thickness Complete All As Specified And Directed. 105 Supply, Installation, Testing And Commissioning Of Submersible Pump Set , Electric Driven 415 V, 50 Hz, Three Phase, 20 Hp, 15 Kw, Speed 2900 Rpm ( Sync ) , Delivery Size Suitable For 150Mm Size Nrv, Having Discharge Capacity 670 Litres Per Minute At 75 Metre Head, Suitable For Lowering Inside Existing Casing Pipe Of Bore Well ( 300 / 350Mm ) Including Necessary Jointing To Existing Gi Column Pipes With Flanged Joints, With Rubber Gaskets, Nut, Bolts & Washers Of Required Size, And Including Electrical Connection From Starter Panel To Motor With Existing Submersible Cable, Complete All As Specified And Directed. [ Model No :- ‘Upha 293 / 4 + Hbc 203’ Of Make ‘Ksb’ Or Equivalent Model Of Make ‘Crompton Greaves / Calama ] . Note:- Column Pipe With Flanged Joints And Submersible Cable Will Be Measured And Paid Seperately. 106 Materials And Labour For, Flat Three Core, Pvc Insulated Industrial Cable For Submersible Motor, 10.00 Sq. Mm ( Nominal Area ) With Multi Stranded Copper Conductor, 1100 Volts Grade, Conforming To Is: 694 All As Per Product Code No Whpndskb3010 Of Make ‘Havells’ Or Equivalent Make Of Finolex / Rr Cable, Connected From Starter To Submersible Pump Motor, Complete All As Specified And Directed. 107 Supply, Installation, Testing And Commissioning Of Chlorine Solution Dosing System ( Make Of Approved List Of Department And Approved By Pm ) Comprising Of Dosing Pump ( Suitable For Chlorine Solution Prepared From Calcium Based Granules ) , Ac, Single Phase, 230 Volts, 50 Hz, Electrically Operated With High Starting Torque, Having Positive Displacement Diaphragm Type Accurated By A Solenoid Solid State Pulsar, With Discharge Capacity Of 1 To 8 Litres / Hour Of Standard Mixture Of Calcium Based Calcium Base Chlorine Granule With Water, Of Any Strength And Suitable For Injecting Chemical Mixture At 4 To 6 Kg Per Sq Cm Pressure, With Provision Of Polypropylene / Ldpe Suction And Discharge Pipes Of Suitable Size And Length With Swing Seal Foot Valve At Bottom End Of Suction Pipe, And With 100 Litres Capacity Frp Tank With Frp Lid Having Post Hole For Pouring Calcium Based Chlorine Granules And Water, Including Provision For Mounting The Dosing Pump On The Lid / Wall Of Frp Tank , Provision Of Level Gauge, Agitator ( 1280 To 1400 Rpm ) With Shaft And Blade In Ss 316 ( Frp Coated / Epoxy Coated / Plastic Coated ) Mounted On Tank Complete With All Accessories Required For Installation As Per Manufacturers Instructions Including Supply Of 02 ( Two ) Years Normal Maintenance Spares I.E. ( I ) Pvc Pump Roller Tube – 02 ( Two ) Nos. ( Ii ) Mixing Blade Complete With Pvc Shaft And Pin As Per Manufacturers Instructions – 02 ( Two ) Sets. And Including Making Provision Of Mounting The Pump Set And Provision Of Pcc Foundation For Placing The Frp Tank, Complete All As Specified And Directed. 108 Supply, Installation, Testing And Commissioning Of Integrated Water Treatment Plant Including All Mechanical Works, Electrical Control Panel, Piping Works, Interconnection Works, Civil Works In Foundations And Required Components With Accessories As Per Details Here In After Complete All As Specifies And Directed. ( A ) Dual Media Filter Plant. 50 Cum / Hr Capacity For Removal Of Suspended Solids, Dirt, Reduce Silt Density Index, Reduce Turbidity Limit And Lower Down The Parameters Upto Permissible Limits As Per Is: 10500, Complete With Ms Epoxy Coated Vessel As Per Is 2825 [ Thickness Not Less Than 8Mm ] , With Suitable Filter Media ( I ) Anthracite, Iii ( Quartz Sand Iv ) Coarse Sand Etc. And With Suitable Common Raw Water Feed Pumps, Common Air Compressor, Common Back Washing Pumping Facility, Mechanical, Electrical Control Panel, Piping Works, Pressure Guage 10 Kg / Cm2. Material Quality Is: 2062 Design Is: 2825 For Shell. ( B ) Iron Removal Filter Plant. 50 Cum / Hr Capacity For Removal Of Iron From The Raw Water And Lower Down Upto Permissible Limit, Complete With Ms Epoxy Coated Vessel As Per Is 2825 ( Thickness Not Less Than 8 Mm ) , With Suitable Filter Media I ) Sand, Ii ) Gravel, Iii ) Mno2, Iv ) Berm Etc. And With Suitable Common Air Compressor, Common Back Washing Pumping Facility, Mechanical, Electrical Control Panel, Piping Work, Pressure Guage 10 Kg / Cm2. Material Quality Is: 2062 Design For Shell. ( C ) Activated Carbon Filter Plant. 80 Cum / Hr Capacity For Removal Of Color, Smell / Odour, Free Residual Chlorine And Oil From The Raw Water And Lower Down Upto Permissible Limit As Per Is:10500, Complete With Ms Epoxy Coated Vessel As Per Is:2825 ( Thickness Not Less Than 8 Mm ) , Suitable Media [ ( I ) Activated Carbon With High Degree Of Microporosity Etc. ] And With Suitable Common Air Compressor, Common Back Washing Pumping Facility, Mechanical, Electrical Control Panel, Piping Works, Pressure Guage 10 Kg / Cm2. Material Quality Is:2825 For Shell. ( D ) 02 ( Two ) Nos [ 01 Working + 01 Standby ] Best Efficient, Suitable Common Raw Water Feed Pumps. ( E ) Commom Air Compressor ( F ) Common Back Washing Pumping Facility. ( G ) All Mechanical, Electrical, Control Panel, Piping, Civil Works, Pressure Gauges, Cocks, Air Vent Systems, Back Washing Arrangements With Suitable Size Ci Sluice / Butterfly Valves. 109 Supply, Install, Testing & Commissioning Of Centrifugal Monoblock Pump Set Of Cast Iron Impeller With Gland Packing Coupled With Induction Moter With ‘F’ Classs Insulation And Ip 55 Protection Suitable For 3 Phase, 300 To 415 Volts, 2900 Rpm, Discharge Not Less Than 10 Lps At Minimum 36 Meter Head With Power Rating 7.5 Kw And 10 Hp, Impeller, Delivery Casing And Moter Body Made Of Cost Iron, Pump Shaft Made Of Carbon Steel, Sealing With Gland Packed. Suitable For Suction From Pipe Of Size 50 Mm Dia And Delivery To Pipe Of Size 40 Mm Dia Including Of Star Delta Starter Of Brand Schneider With Single Phase Preventer And Over Load Protection , With Provision Of 3 Crore 10 Sqmm Flat Copper Cable From Starter Pannel To Pump Set, Priming Line Watering Arrangement Complete Using 20Mm Dia Gl Pipe Med Grade Of Length Upto 10 Rm, Gate Valve 20Mm Dia- 10 No With Necessary Pcc Foundation With Suitable Size Of Nuts, Bolts Grouted & Washers And Complete All As Specified And As Directed And The Ratesare Inclusive Of Testing Of Pump Set Installation For Satisfactory Functioning / Running & Minimum 2 Years Warranty Complete All As Specified And Directed. Make:-Kirloskar / Crompton / Ge 110 Supply And Fix Fully Automatic Star Delta Strarter In Sheet Steel Enclosure, Suitable For 20Hp Motor ( 30 Hp Starter ) 3 Phase , 415 V, 50 Hz Relay Range 13-21 A, Coil Voltage 360V As As Per Specified And Directed. Make:- L & T Or Equivallent In Bch / Seimens / Abb 111 Supply, Installation, Commissioning Andtesting Silent Diesel Engine Driven Generating Set50 Kva ( 40 Kw At 0.8 Pf ) Capacity 415 Volts, 3 Phase, 4 Wire & With Includingacoustic Weather Proof Enclosure As Per Cpcb Norms And Noise Level Shall Not Be Exceeding 75 Db At A Distance Of 1 Metre From All Sides, Complete In All Respects & Comprising The Following Components. Make :- Kirloskar Green / Kirloskar Cummins 112 ( A ) Diesel Engine Developing Suitable Bhp At 1500 Rpm Conforming To Bs 5514 / Iso0346series Inclusive Of The Following Accessories:- 113 ( I ) Radiator And Radiator Fan 114 ( Ii ) Spider Coupling Guard 115 ( Iii ) Fly Wheel 116 ( Iv ) Fly Wheel Housing Complete With Starter Gear Ring And Coupling As Per Manufacturer Design. 117 ( V ) Air Cleaner Dry Type. 118 ( Vi ) Fuel And Lubricant Oil Filter. 119 ( Vii ) By-Pass Filter 120 ( Viii ) Coolant Inhibitor 121 ( Ix ) Fuel Pump Dtr Type / In Line Mono Block Fuel Injecting Pump. 122 ( X ) Water Pump 123 ( Xi ) Lub Oil Pump And Inclusive Of First Filling Of Lubricant Oil & Coolant. 124 ( Xii ) Electric Starter 12 Volts Dc As ManufacturerS Design. 125 ( Xiii ) Battery Charging Generator ( Dc Alternator ) 126 ( Xiv ) Industrial Silencer 127 ( Xv ) Lubricant Oil Cooler 128 ( Xvi ) Flexible Pipe For Silencer 129 ( Xvii ) Dc Volt Meter 130 ( Xviii ) Water Temperatures Gauge, Lub Oil Pressure Gauge 131 ( Xix ) Speedo Meter And Engine Running Hours Meter 132 Xx ) Display For Fault 133 ( Xxi ) Suitable Size Of Turbo-Charger 134 ( Xxii ) Shut Off Coil With Safeties For Llop / Hwt. 135 ( Xxiii ) Mechanical Governor. 136 ( Xxiv ) Maintenance Free Secondary Batteries12 Volts As Per Manufacture Design. 137 ( Xxv ) Safeties And Indications Against Low Lube Oil Pressure & High Coolant Temperature. 138 ( Xxvi ) In-Line Monoblock Fuel Injection Pump With Mechanical Governor And Fuel Feed Pump. 139 ( Xxviii ) Engine Mounting Supports. 140 ( Xxix ) Engine Control Panel Consisting Of Off / On / Start Keys, Lube Oil Pressure Gauge, 141 ( Xxx ) Ammeter, Electric Hour Meter. 142 ( Xxxi ) Engine Operator / Maintenance & Spare Parts Manual. 143 ( Xxxii ) Engine Spare Parts Manual. 144 ( Xxxiii ) Engine Warranty Certificate. 145 ( Xxxiv ) Engine Test Certificate. 146 ( Xxxv ) Asbestos Rope 147 ( B ) Alternator:-Synchronous Alternator 50 Kva, 1500Rpm, 415 Volts, 50Hz, 3 Phase System, Brushless Type, Screen Protected Revolving Filled Self Excited, Self Regulated, Confirming To Is 4772 Of 1992 / Bs 500. 148 ( C ) Amf Panel : Amf Panel Shall Be Of Suitable Size, Factory Made, Indoor Cubical Type, Front Openable, Fabricated From Crca Steel Sheet 1.6 Mm Thick Complete As Per Manufacturer Specification Of Diesel Engine Suitablefor Dg Set Of Capacity 50 Kva, Grouted In Floor With Pcc 1 :2:4 Type B-2 Foundation Of Suitable Size As Per ManufacturerS Recommendations Complete In All Respects. Cables Are Ferruled For Proper Maintenance / Checking / Wiring Of Panel. Detachable Cable Gland Plates Are Provided. The Panel Will Be Equipped As Follows: 149 ( I ) Contactor Mlof Suitable Capacity 150 ( Ii ) Copper Bus Bar Of Current Rating Up To 100 Amp 151 ( Iii ) Sensitivity Relay Set With Suitable Cts 152 ( Iv ) Electronic Latch Circuit With Tripping Indication 153 ( V ) Instantaneous Tripping Device For Complete Panel Over Current 0.5 Amp. 154 ( Vi ) Reset Facilities For Complete Protection Of Amf Panel 155 ( Vii ) Self Sequential Starting Relay Unit 12 Volts Dc Complete With Alarm Contactor. 156 ( Viii ) Electronic Timer 220 Volts For Main Contactor With 1 No. Nc Auxiliary Contacts 157 ( Ix ) Electronic Timer 220 Volts But For Fuel Cut Operation With 1 No. Nc Auxiliary Contacts. 158 ( X ) Battery Charging Unit 12 / 24 Volts 10 Amp Complete With Digital Volt Meter & Amp Meter. 159 ( Xi ) All As Per Item No- ( Ix ) Here In Befor But For Fuel Cut Off Operation. 160 ( Xii ) Electric Starter 12 Volts Dc As ManufacturerS Design. 161 ( Xiii ) . Digital Voltmeter 0-500 Volts Panel Mounting Type Size 96Mm Square With Selector Switch Digital 162 ( Xiv ) 3 Phase Electronic Energy Meter For Measuring Meter For Measuring Generated Units . 163 ( Xv ) Frequency Meter Digital Type 164 ( Xvi ) Suitable Type Of Mccb For Main Supply / Dg Supplyadjustable Over Load And Adjustable Short Circuit . 165 ( Xvii ) The Amf Panel Shall Have By Pass Arrangement Incase Failure Of Bypass Amf Panel 166 ( Xviii ) Acoustic Enclosure With Natural Air Curculation Without Loss Of Any Power To Ventilation Fan. The Enclosure Shall Be Modular In Construction With Hinged Bolted Structure To Provide Easy Dismantling And Shall Be Made Out Of High Quallity Crcasteel Sheet Of 1.6Mm Thick With Sufficient Accessories For Maintenance Work Openable And Lockable Door Air Tight Gasket Interior Lightening Arangement Of 20W Fitting With On / Off Switch To Meet Latest Emission Norms. 167 ( Xix ) Fuel Tank Of Suitable Capacity With Inlet And Outlet Connectiions And Fuel Level Indicator As Per Oem. 168 ( Xx ) Base Frame Made Out Of Suitable Channel Duly Reinforced And Provided With Adequate Numbers Of Anti Vibration Pads To Ensure Minimum Vibration As Recommended By Manufacturer. 169 :Supply Install Testing And Commissioning Factory Made Lt Panel Boardindoor Type ( Cpri Approved ) Made Out Of 3.15 Mm Thick Sheet Metal Angle Iron Base Frame Wisuitable For Ac 3 Phase 4 Wire 50 Hz Supply Complete Panel Duly Painted With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Platform Of Suitable Size With Shutter And Locking Arrangement For Each Switchgear And Busbar Of Aluminium Conductor Suitable Shape And Size For 3 Phase Rating Of 100 Amps The Follwing Switchgear & Controls. Incoming :- ( A ) 3 Phase 4 Wire 50 Hz Mccb 4 Pole 415 V 40 Amps -2 Nos. ( B ) Ammeter 0- 1000 Amps 96 Mm X 96Mm Electro Mechancial Type With Three Way On / Off Rotary Type Selector Switch And 3 Current Transformer Of Suitable Ratio And Capacity Qty 1 No ( C ) Indicating Lamps For Three Phases Qty 1 Set Of 3 Nos ( D ) Voltmeter 0 - 500 Volts 96 Mm X 96Mm Electro Mechanical Type With 3 Way On / Off Rotary Type Selector Switch - Qty 01 No Make Ae / Rishab / Meco / Enercon ) . Outgoing:- ( A ) 4 Pole Mccb 40 Amp, 50 Hz, 415 V, 25 Ka -02 Nos. ( B ) Dol Starter - 2 Nos. 170 Supply, Install, Testing & Commissioning Of Centrifugal Monoblock Pump Set Of Cast Iron Impeller With Gland Packing Coupled With Induction Moter With ‘F’ Classs Insulation And Ip 55 Protection Suitable For 3 Phase, 300 To 415 Volts, 2900 Rpm, Discharge Not Less Than 5 Lps At Minimum 36 Meter Head With Power Rating 3.73 Kw And 5 Hp, Impeller, Delivery Casing And Moter Body Made Of Cost Iron, Pump Shaft Made Of Carbon Steel, Sealing With Gland Packed. Suitable For Suction From Pipe Of Size 50 Mm Dia And Delivery To Pipe Of Size 40 Mm Dia Including Of Star Delta Starter Of Brand Schneider With Single Phase Preventer And Over Load Protection , With Provision Of 3 Crore 10 Sqmm Flat Copper Cable From Starter Pannel To Pump Set, Priming Line Watering Arrangement Complete Using 20Mm Dia Gl Pipe Med Grade Of Length Upto 10 Rm, Gate Valve 20Mm Dia- 10 No With Necessary Pcc Foundation With Suitable Size Of Nuts, Bolts Grouted & Washers And Complete All As Specified And As Directed And The Ratesare Inclusive Of Testing Of Pump Set Installation For Satisfactory Functioning / Running & Minimum 2 Years Warranty Complete All As Specified And Directed . Make:-Kirloskar / Crompton / Ge 171 Sewage Disposal 172 M&L For Loose Filling Broken Sewer Bricks / Brick Bats As In Soakage Pits / Soakage Wells Complete All As Specified And Directed. 173 M&Lpreparation Of Newly Plastered Or Unplastered Surface And Applying Two Coats Of Weather Proof Paint To External Surface Of Wall ( Apex Ultima ) Complete All As Specified And Directed. 174 Air Conditioning & Refrigerator :- 175 Supply, Installation And Commissioning Bee 5 Star Rated , Double Door Refrigerator Of Capacity 280 Ltr, Smart Invertor Frost Free Complete With Humidity Control, Smart Inverter Compressor, Smart Connect, Jet Ice, Anti Bacterial Gasketworking On Single Phase 230V, 50Hz All Complete All As Specified And Directed. 176 Supply, Installation And Commissioning Bee 5 Star Rated , Double Door Refrigerator Of Capacity 220 Ltr, Smart Invertor Frost Free Complete With Humidity Control, Smart Inverter Compressor, Smart Connect, Jet Ice , Anti Bacterial Gasketworking On Single Phase 230V, 50Hz Complete All As Specified And Directed. 177 Supply, Installation And Commissioning Ofdeep Freezer Hard Top Of 150 Ltr Capacity Working On Single Phase Supply I.E 230V, 50 Hz Having Single Door, Cooling Range 18 Degree Centrigrade To 22 Degree Centrigrade, Including Locking Arrangement With Recess Handle For Durability, Heavy Duty Castor Wheelsat Bottom Of Freezeer With High Density Puff Insulation For Better Holding Time For Items Kept Inside Complete All As Specified And Directed. 178 Supply, Installation And Commissioning Stablizer For Automatic Operation Single Phase Naturally Air Cooled Indoor Type & Drsinged For Input Variation Between 170V To 250V With Output Voltage Stablized At 230 V With Accuracy Of + 2.5% Of 1 Kva Complete All As Specified And Directed. 179 Solar Water Heating System :- 180 Supply & Fixing Water Heater ( Geyser ) , Storage Type Electric Of25 Ltr Capacity, Bee 5 Star Rating, Including Fixing On Wall With Nuts And Bolts Etc., Pvc Connection Pipe Of Required Length For Hot And Cold Water Supply Complete All As Per Specified And Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-01-2024

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
INR 81.80 Crore /-

BOQ Items

Name of Work:PROVISION OF OTM ACCN & ALLIED FACILITIES FOR INF BN NO 3 AT ALONG UNDER CCE (ARMY) NO 1, DINJAN (Tender ID :2023_MES_611168_3)
Sl. No. Item Description
1Total amount of Sch "A" Part I (Building and Structure) (Pre Priced Amount as in Col 7, brought forward from Total of Sch "A" Part-I)
2Total amount of Sch "A" Part II (Dismantling and Demolition of Buildings) (Pre Priced Amount as in Col 7, brought forward from Total of Sch "A" Part II)
3Total amount of Sch "A" Part III (Site Clearence, Earth Work AndArea Development) (Pre Priced Amount as in Col 7, brought forward from Total of Sch "A" Part III)
4Total amount of Sch "A" Part IV (Retaining Wall (For Height Upto 5.5 M) (Pre Priced Amount as in Col 7, brought forward from Total of Sch "A" Part IV)
5Total amount of Sch "A" Part V (Internal Electrificationand Lightning Protection) (Pre Priced Amount as in Col 7, brought forward from Total of Sch "A" Part V)
6Total amount of Sch "A" Part VI (Internal Water Supply) (Pre Priced Amount as in Col 7, brought forward from Total of Sch "A" Part VI)
7Total amount of Sch "A" Part VII (Road / Path / Culvert) (Pre Priced Amount as in Col 7, brought forward from Total of Sch "A" Part VII)
8Total amount of Sch "A" Part VIII (External Electrification) (Pre Priced Amount as in Col 7, brought forward from Total of Sch "A" Part VIII)
9Total amount of Sch "A" Part IX (External Water Supply) (Pre Priced Amount as in Col 7, brought forward from Total of Sch "A" Part IX)
10Total amount of Sch "A" Part X (Sewage Disposal) (Pre Priced Amount as in Col 7, brought forward from Total of Sch "A" Part X)
11Total amount of Sch "A" Part XI (Area Drainage) (Pre Priced Amount as in Col 7, brought forward from Total of Sch "A" Part XI)
12Total amount of Sch "A" Part XII (Fencing and Gate) (Pre Priced Amount as in Col 7, brought forward from Total of Sch "A" Part XII)
13Total amount of Sch "A" Part XIII (Solar Water Heating System) (Pre Priced Amount as in Col 7, brought forward from Total of Sch "A" Part XIII)
14DISMANTLING AND DEMOLITION OF BUILDINGS
15Taking down old copper / aluminium point wiring (light, fan socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, complete all as specified and directed.
16Taking down ceiling fan / exhust fan, of any size and capacity and deposite to MES store yard complete all as specified and directed.
17Taking down MCBsDB and connected service cable of any type, capacity and size complete all as specified and directed.
18Taking down geyser of capacity upto 25 Lts in any position and situation and deposite to MES store5 yard complete all as specified and directed.
19INTERNAL ELECTRIFICATION & LIGHTENING PROTECTION:-
20Supply and fix flame proof / weather proof rotary on /off switch complete all asspecified and directed
21M & L for concealed flush to wall factory made sheet metal enclosure for MCB DBs, Manufactured prewired double door designed, DB"s VTPN 415V12 way 63 Amp fixed on wall / MS box complete with copper bus bar neutral link dinrail suitable for mounting MCCB"s complete, IP-54 protection complete all asspecified and directed.
22M & L for concealed flush to wall factory made sheet metal enclosure for MCB DBs, manufactured prewired double door designed, DB"s VTPN 8 way63 Amp fixed on wall / MS box complete with copper bus bar neutral link dinrail suitable for mounting MCCB"s complete, IP-54 protectioncomplete all asspecified and directed.
23S & FLED tube light 22 Watt Delite Plus LED Tube Light , 6500K Surface / Recess mountedDecorative ultra slim aluminium square profile LED lighting fixture with high lumen output, environmental friendly, energy efficient, etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizecomplete all asspecified and directed. Make:- Havells or equivalent make as approved by PM.
24S & FLED Tube Light 20 Watt E-Lite LED Pride Plus , 6000K Surface/Recess mountedDecorative ultra slim aluminium square profile LED lighting fixture with high lumen output, environmental friendly, energy efficient, etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make:- Havells or equivalent make as approved by PM.
25S & F flame Proof LED 20 Watt CMRI Certified LED Flameproof suitable for Gas / Vapor Group of IIA & IIB and Zone 1 & 2. IP65 Protection,complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all asspecified and directed Make- Crompton or equivalent make as approved by PM.
26S & FLED Tube Light 18 Watt E-Lite LED Pride Plus , 6000K Surface/Recess mountedDecorative ultra slim aluminium square profile LED lighting fixture with high lumen output, environmental friendly, energy efficient, etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all asspecified and directed. Make- Crompton or equivalent make as approved by PM.
27S & F LED Tube Light 2x18 Watt Magnum Retro,long life, corrosion resistant, impact proof, surface mounting IP65 luminaire with PC housing & opal finish cover suitable for LED tubes, etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all asspecified and directed Make- Crompton or equivalent make as approved by PM.
28S & F Bulk Head with 10W LED Light (Cat No. LHEOAOP7UZ6W010) with all accessories suitable for fitting and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50Hz complete all asspecified and directed. Make- Crompton or equivalent make as approved by PM
29S & F 6 Watt LED Light for mirror4000K AC 170-240V, complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all asspecified and directed.
30S & F 24W Recess mounted Downlighter with pressure die-cast aluminium heat sink & PC diffuser in white powder coated finish with integrated driver. Product desvription 24W 830 complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all asspecified and directed.Make- Havells or equivalent make as approved by PM
31S & F 15 Watt EDGE Plus Series LED Street Light (Cat No. BRLEP 15W LED) pressure die cast housing with toughened glass and individual LEDs with secondary optics and IP65 Protection, complete with all accessories like GI Pipe suitable for fitting and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50Hz. complete all asspecified and directed. Make- Bajaj or equivalentmake as approved by PM
32S & F HD 750 mm sweep (SS-390 Metallic) ceilling fan including cost of material, labour and T & P as per drawing complete, for proper completion of work complete all as specified and directed. Make:- Crompton/Khatian/Havells/Orient
33S & F Telephone Jack Modular with Shutter Type fixed on 2 Module white cover plate with fram, 2 Module metal flush Box complete all as specified and directed.
34S & F drawing twin core telephone wire 0.5mm in PVC conduit of 25mm size complete in all respect, including cost of material, labour and T & P as per drawing complete all as specified and directed.
35S &F T.V Socket with ShutterType fixed on 2 Module white cover plate with fram, 2 Module metal flush Box completedrawing 25mm dia PVC concealed conduit connection complete in all respect complete all as specified and directed.
36S & F Co-Axial TV Cable Electrolytic grade solid annealed Copper conductor, JF, Al wire Braided (RG-6 Foam type)in PVC conduit of 25mm size complete in all respectcomplete all as specified and directed.
37ROAD / PATH / CULVERT :-
38M & L for applying 3mm thick retro reflective thermoplastic road marking paint using thermoplastic road marking compound, conforming to MORTH, AAHTO M249 and BS 3262 with 30-40% pre mixed glass beads conforming to BS 6088, on existing road surfaces including preparation of surface complete all as specified and directed.
39S & F Cat Eyes / Glow studs of size 100x100x20mm, made of heavy duty body fixed on the road as per manufacturer"s instructioncomplete all as specified and directed..
40S&F Sign boards on road as 900mm x 600mm size, as per IRC made out of 2.0mm thick aluminium sheet with front face of aluminium sheet to be fully covered by white diamond grade micro prismatic type 1 x Retroreflective sheeting matter by over lay red colour film and back side painted with grey appoxy paint including fixing provision of 1 post of MS pipe 75mm dia 3.80m long dully painted in black and white alternate bands of synthetic enamel paint and hold fast at bottom complete in all respects all as approved by PMcomplete all as specified and directed.
41EXTERNAL ELECTRIFICATION :-
42Supply, install, testing and commissioning of HT 11 KV, 18.4 KA, 3 Phase, 50 Hz 3 wire totally enclosed metal clad ,extensible type indoor floor mounted horizontal draw, horizontal isolation type Vacuum Circuit Breaker 400 Amps motor operated spring charged having rupturing capacity 250 MVA and consisting of the following :- 01No 11KV, 400 Amps, VCB comprising of :- (i) Assembly of 3 vaccum interrupters complete with epoxy support insulator and self-aligning finger type isolating contacts. (ii) Hand and motor(220 volt AC) charged independent spring closing/tripping trip free operating mechanism with manual closing and tripping push buttons and mechanical breaker closed /open, spring charged/discharged indication. (iii) Electrical release coil 24V DC- 01 No (iv) Mechanical operation counter. (v) Breaker operated auxiliary switch-03 Nos (vi) Bus bar chamber including a set of 3 phase 630 Amp copper bus bar -01 No (vii)230 volts AC single phase 80 W rated strip type heater -02 Nos with indicator complete. (viii) Voltagetransformer (VT) incorporating 3 phase 3 limb with drawable type VT having ratio 11KV/110V and output of 100 VA per phase with accuracy class I as per IS-3155 complete with HT and LT HRC fused n primary and secondary sides respectively (confirming related IS specification) -02 set . (ix) Current transformer (CT) chamber incorporating 3 single phase resin cast, dual ratio CTS of ratio 40/20/5 Amp with suitable VA burden and accuracy class. (j) Rear cable termination provision for terminating 3 core 120 sq. mm XLPE cable. (x) Ammeter dual range with selector switch size 144 sq. mm 0 20/10A.(l) Voltmeter with selector switch
43(xi) Triple pole non-directional IDMT relays having minimum 02 element for over current setting 50% -200% and one element for earth fault protection setting 20%-80% with instruments high set element -01 (xii) On/Off /Trip Indication-01(xiii) TNC Switch-01 (xiv) 3 Phase RYB indications with lamp & holder - 01 set with cable glands of suitable size (xiii) Trip circuit healthy indication lamp with push button-01 (xv ) Power factor meter digital type-01 (xvi) Frequency meter -01 (xvii) Cable gland of suitable size (xviii) Shunt trip 24 volts DC including maintenance free battery bank, batterycharger (xix) In built integral earthing (xx) Electronic, digital KWH meter CT type suitable for metering CT-01 No.complete all as specified and directed. Make Crompton/Schneider/ABB/ITE Gurgaon
44Supply and installation of 11 KV single phase in door resin cast CT of ratio 400/5- 5A class 1.0/ 5P10,burden 15VA – 15 VA, including all connectioncomplete all as specified and directed.
45Supply and installation of 11 KV single phase in door resin cast PT of ratio 11 KV/rt3/110 V/rt3/110V/rt3,Class 0.5-3, Burden 50 VA – 50 VA, including cost of material, labour including making all connectioncomplete all as specified and directed.
46Supply and fix HT 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators of rating upto 200 Amps, complete all as specified and directed.
47Supply and fix lightning arrestor HT 11 KV 10 KA station class, duly fixed on two pole structurecomplete all as specified and directed.
48Supply & install, testing and commissioning indoor type 30 Volts battery bank including charger suitable for and including 15 C Batteries of 120AHinput supply single phase 230 volts and output Float 24-35 Volts DC @10 A, Boost 29 Volts at power factor 0.8 and degree of protection IP 4X, complete internal wiring with suitable copper condutor wires and each battery & charger should bemounted in the same panel with suitable ventilation, floor mounting panel fabricated out of 2 mm thick CRCA sheetwith suitable angle iron frame and legs made of suitable angle iron, painted with powder coated and pre coted primer including with locking arrangement complete all as specified and directed by Engr-in-Charge. Make : ABB/Schnieder/Seimens/ L & T
49Supply, installation testing and commissioning of digital UPS system for power back up single phase AC input 140Vto 270V and out put 220V + 10% capacity 4 KVA including 02 Nos , 12V batteries of 150 AH, VRLA (Valve regulated lead acid batteries with interconnection cables and battery rack complete all as specified and directeed.
50Supply & laying Synthetic Insulating mat of size 2.00Mtrx 1.00Mtrx 19 mm thickcomplete all as specified and directed .
51Supply and fixing 40 mm dia GI pipe for street light bracket on LT pole"medium grade"of 1.5 mtr long and make to shape fixing with suitable size of flat iron clamp nut , bolts and washers connection including two coat of synethetic enamel paint over a coat of red oxide zinc chrome primer and fixing the light fitting on bracket and all the electrical connection complete all as specified and directed.
52Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protectioncomplete all as specified and directed.
53Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, indoor type, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus barsof 600 Ampinsulated on porcelain insulators.The panel shall be dust and vermin proof, IP 54 class protection and made of2mm CRCA MS Sheetand 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm.The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (for transformer No-01 (200 KVA) (a)Bus bar chamber of 3 phase andneutral 4 strip415 volts with 600 Amps Aluminium - 1 set (a)3 Phase 4 wire 50 Hz MCCB 4 Pole 415 V 400 Amps, 35 kA -2 Nos.(Incoming)(b) Ammeter 0- 1000 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No(c) Indicating lamps for three phases Qty 1 set of 3 Nos
54(d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). Outgoing:- (a) 4 pole MCCB 63 Amp 50 HZ 415 V,25 kA-1 no.(b) 4 pole MCCB 160 Amp 50 Hz 415 V, 35 kA - 01 no. (c). 4 pole MCCB 100 Amp 50 Hz 415 V, 35 kA - 01 no (d) TPN 40 Amp , 50 HZ 415 V, 35 kA -01 No (e). On load Change over Switch of capacity 400Amp - 1 No. (f). MCCB 400 A, 36 kA - 1 No. , including cost of material, labour and T & P as per drawing complete, for proper completion of workall as specified and directed.. (d) Platform of panel :- platform for the pane with PCC 1:4:8 type D2 with 40mmgraded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class "B" old size bricks, rendering 15cm thicj in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel TheThe various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level. Notes :- (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel whitepaint.
55Supply installng testing and commissioning factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 250 Ampinsulated on porcelain insulators.The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheetand 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm.The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Location E) (a)MCCB 4 pole 415 V 160 Amps.35 KA Adjustable type -2 No (01 Spare)(Incoming)(b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No(c) Indicating lamps for three phases Qty 1 set of 3 Nos(d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon).
56Outgoing:- (a) 4 pole MCCB 63 Amp, 50 HZ 415 V-02 nos. (b). 4 pole MCCB 40 Amp, 50 HZ 415 V-01 no.(c) TPN 40 Amp , 50 HZ 415 V -01 No , including cost of material, labour and T & P as per drawing complete, for proper completion of work all as specified and directed. (d) Platform of panel :- platform for the pane with PCC 1:4:8 type D2 with 40mmgraded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class "B" old size bricks, rendering 15cm thicj in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3: 6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel TheThe various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level. Notes :- ote :(i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel whitepaint.
57Supply installng testing and commissioning factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 100 Ampinsulated on porcelain insulators.The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheetand 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm.The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Location C ) (a)MCCB 4 pole 415 V 63 Amps, 25 kA -2 Nos (1 Spare)(Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No(c) Indicating lamps for three phases Qty 1 set of 3 Nos(d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon).
58Outgoing:-a) 4 Pole MCCB 40 Amp, 50 Hz 415 V, 25 kA -02 Nos, including cost of material, labour and T & P as per drawing complete, for proper completion of work and as per direction of Engineer in Charge. (d) Platform of panel :- platform for the pane with PCC 1:4:8 type D2 with 40mmgraded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class "B" old size bricks, rendering 15cm thicj in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel TheThe various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level. Notes :- (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel whitepaint.
59Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, indooor type, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus barsof 1200 Ampinsulated on porcelain insulators.The panel shall be dust and vermin proof, IP 54 class protection and made of 2mm CRCA MS Sheetand 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm.The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (for transformer No-02 (315 KVA) (a)Bus bar chamber of 3 phase andneutral 4 strip415 volts with 1200 Amps Aluminium - 1 set (a) 3 Phase 4 wire 50 Hz ACB4 Pole 415 V 800 Amps, 50 kA -1 Nos.(Incoming)(b) Ammeter 0- 1000 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No(c) Indicating lamps for three phases Qty 1 set of 3 Nos
60(d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). Outgoing:- (a) 4 pole MCCB 63 Amp, 50 HZ 415 V, 25 kA-1 no.(b) 4 pole MCCB 160 Amp 50 Hz 415 V, 35 ka - 01 no (e). 4 pole MCCB 125 Amp 50 Hz 415 V, 35 ka - 01 no.(d). 4 pole MCCB 100 Amp 50 Hz 415 V, 35 kA - 01 no. (f) 4 pole MCCB 40 Amp, 50 HZ 415 V, 25 ka-2 nos. (g) TPN 40 Amp , 50 HZ 415 V , 25 kA-01 No (h). On load Change over Switch of capacity 400Amp - 1 No. (j) 3 Phase 4 Wire 50 Hz 400 Amp MCCB, 35 kA -01 (For Ring Main) , including cost of material, labour and T & P as per drawing complete, for proper completion of work and as per direction of Engineer in Charge. (k) Platform of panel :- platform for the pane with PCC 1:4:8 type D2 with 40mmgraded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class "B" old size bricks, rendering 15cm thicj in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel TheThe various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level. Notes :(i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item. (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel whitepaint.
61Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 250 Ampinsulated on porcelain insulators.The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheetand 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm.The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Location K ) (a)MCCB 4 pole 415 V 160 Amps, 35 ka-2 Nos (1 Spare)(Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No(c) Indicating lamps for three phases Qty 1 set of 3 Nos(d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon).
62Outgoing:-a) 4 Pole MCCB 63 Amp , 50 HZ 415 V, 25 kA -03 Nos, (e) Platform of panel :- platform for the pane with PCC 1:4:8 type D2 with 40mmgraded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class "B" old size bricks, rendering 15cm thick in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel TheThe various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level. Notes :- (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel whitepaint.
63Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 200 Ampinsulated on porcelain insulators.The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheetand 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm.The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Location L ) (a)MCCB 4 pole 415 V 125 Amps, 35 ka-2 Nos (1 Spare)(Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No(c) Indicating lamps for three phases Qty 1 set of 3 Nos(d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon).
64Outgoing:-(a) 4 Pole MCCB 63 Amp , 50 HZ 415 V, 25 kA -02 Nos, (b) Platform of panel :- platform for the pane with PCC 1:4:8 type D2 with 40mmgraded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class "B" old size bricks, rendering 15cm thicj in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel TheThe various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level. Notes :-(i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel whitepaint.
65Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 160 Ampinsulated on porcelain insulators.The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheetand 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm.The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Location P ) (a)MCCB 4 pole 415 V 100 Amps, 25 ka-2 Nos (1 Spare)(Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No(c) Indicating lamps for three phases Qty 1 set of 3 Nos(d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon).
66Outgoing:-a) 4 Pole MCCB 63 Amp, 50 HZ 415 V, 25 kA -02 Nos, (e) Platform of panel :- platform for the pane with PCC 1:4:8 type D2 with 40mmgraded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class "B" old size bricks, rendering 15cm thicj in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel TheThe various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level. Notes :- ote :(i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel whitepaint.
67Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, indoor type, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus barsof 100 Ampinsulated on porcelain insulators.The panel shall be dust and vermin proof, IP 54 class protection and made of 2mm CRCA MS Sheetand 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm.The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (LT panel No- 08 , Raw water Pump house) (a)Bus bar chamber of 3 phase andneutral 4 strip415 volts with 100 Amps Aluminium - 1 set (a) 3 Phase 4 wire 50 HzMCCB 4 Pole 415 V 63 Amps, 36 kA -2 Nos.(Incoming)(b) Ammeter 0- 1000 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No(c) Indicating lamps for three phases Qty 1 set of 3 Nos(d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon).
68Outgoing:-(a) 4 Pole MCCB 63 Amp , 50 HZ 415, 25 kA-03 Nos (b) TPN MCB 40A, 25 kA - 1 no. (c). Star Delta starter for 10 HP Motor - 2 nos. (d). Fully automatic Star Delta starter 30 HPfor 20 HP Motor - 1 nos(e) Platform of panel :- platform for the pane with PCC 1:4:8 type D2 with 40mmgraded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class "B" old size bricks, rendering 15cm thicj in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel TheThe various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level. Notes :(i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel whitepaint.
69Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, indoor type, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus barsof 100 Ampinsulated on porcelain insulators.The panel shall be dust and vermin proof, IP 54 class protection and made of 2mm CRCA MS Sheetand 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm.The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (LT panel No- 09 , Clean water Pump house) (a)Bus bar chamber of 3 phase andneutral 4 strip415 volts with 100 Amps Aluminium - 1 set (a) 3 Phase 4 wire 50 HzMCCB 4 Pole 415 V 63 Amps, 25 kA -2 Nos.(Incoming)(b) Ammeter 0- 1000 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No(c) Indicating lamps for three phases Qty 1 set of 3 Nos(d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon).
70Outgoing:-(a) 4 Pole MCCB 63 Amp , 50 HZ 415V, 25 kA-02 Nos (b) TPN MCB 40A, 25 kA - 1 no. (c). Star Delta starter for 10 HP Motor - 2 nos, (d) Platform of panel :- platform for the pane with PCC 1:4:8 type D2 with 40mmgraded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class "B" old size bricks, rendering 15cm thicj in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel TheThe various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level. Notes :- ote :(i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel whitepaint.
71Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 63 Ampinsulated on porcelain insulators.The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheetand 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm.The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Panel 10 for street light ) (a)MCCB 4 pole 415 V 32 Amps, 25 ka- Nos (Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No(c) Indicating lamps for three phases Qty 1 set of 3 Nos(d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon).
72Outgoing:-(a)4 Pole MCCB 32 Amp , 50 HZ 415 V, 25 kA -03 No (b). Timer switch, Controlled relay, Contactors etc, (c) Platform of panel :- platform for the pane with PCC 1:4:8 type D2 with 40mmgraded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class "B" old size bricks, rendering 15cm thicj in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel TheThe various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level. Notes :- ote :(i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel whitepaint.
73Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 160 Ampinsulated on porcelain insulators.The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheetand 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm.The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Panel B) (a)MCCB 4 pole 415 V 100 Amps, 25 kA-2Nos (01 spares)(Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No(c) Indicating lamps for three phases Qty 1 set of 3 Nos(d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon).
74Outgoing- (a) 4 pole MCCB upto 40 Amp 50 HZ 415 V, 25 kA-3 nos., (b) Platform of panel :- platform for the pane with PCC 1:4:8 type D2 with 40mmgraded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class "B" old size bricks, rendering 15cm thicj in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6type -1 (using 20mm graded stone aggregate) on toop and grouting bolts etc for panel TheThe various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level. Notes :- (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel whitepaint.
75Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 160 Ampinsulated on porcelain insulators.The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheetand 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm.The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Panel S ) (a)MCCB 4 pole 415 V 63 Amps, 25 ka- 2 Nos (01 Spare(Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No(c) Indicating lamps for three phases Qty 1 set of 3 Nos(d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon).
76Outgoing- (a) 4 pole MCCB upto 63 Amp 50 HZ 415 V, 25 kA-1 nos.,(b) TPN MCB 40 Amp-01 No (e) Platform of panel :- platform for the pane with PCC 1:4:8 type D2 with 40mmgraded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class "B" old size bricks, rendering 15cm thick in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 (using 20mm graded stone aggregate) on top and grouting bolts etc for panel TheThe various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level. Notes :-(i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel whitepaint.
77Supply and fixing of metal juctionbox ofsuitable size with aluminium bus bar rated for 415 V ,50 Hz, AC supply with10 Amp, SP MCB for controlling of street light,for proper completion of workcomplete all as specified and directed.
78Supply and fixing cable route indicator made out PCC pole (0.3m X 0.3m X 1.0m ) (LXWXH) on H T / LT cable upto 1mtr depth grouted inthe ground with sutaible PCC work with writing LT/HT cable / Jointwith pole number complete all as specified and directed.
79EXTERNAL WATER SUPPLY
80Materials and Labour for centrifugally cast (spun) ductile iron pressure pipes for water mains, with spigot and socketed ends, Class K9, ISI Marked [IS 8329:2000 (Re affirmed 2005)], in any length, jointed by push-on flexible joints with rubber gaskets conforming to IS 5382, laid in trenches, complete all as specified and directed. of following size:- ( For distribution main )
81(a) 200 mm dia.
82(b) 150 mm dia.
83(c) 100 mm dia.
84M & L for construction of valve chamber for gate / sluice valve offollowing size all as specifiedincluding necessary excavation and earthwork, MS sheet cover and angle iron frame, painting with two coats of synthetic enamel paint over a coat of redoxide zinc chrome primer including necessary locking arrangement of following sizes complete all as specified and directed.
85(a) 1.2M x 1.2M x 1.2 M
86b) 0.9M x 0..9M x 0.9 M
87(c) 0.75M x 0.75M x 0.75M
88Materials and Labour for,100 mm bore, centrifugally cast (spun) ductile iron pressure pipes for water mains, with spigot and socketed ends, Class K7, ISI Marked [IS 8329:2000 (Reaffirmed 2005)], in any length, jointed by push-on flexible joints with rubber gaskets conforming to IS 5382, laid in trenches, complete all as specified and directed.
89Supply and laying ductile iron fittings for spigot and socketedpipes such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs, ISI Marked [IS 9523 :2000 (Re-affirmed 2005)], suitable for bore of pipe up to 450 mm, complete all as specified and directed.
90S & F Valve reflux with by pass arrangements supplied and installed complete of size 100 mm dia,complete all as specified and directed.
91M & L for Drilling trial Bore of suitable diameter with reverse rotary circulation or direct circulation method or combination of both by using power rig for housing B345:D348of 250 mm nominal bore reduced to 150 mm below ground level in any kind of soil strata including hard stone/ boulder etc. complete all as specified and directed.(100 Mtrx 02 borewell as different location) complete all as specified and directed. NOTE:- The anticipated depth of boring of the tube well at site is 100 metres below ground level. However, the depth of boring may be varied maximum upto 40 Metres (Plus or Minus) as ordered by PM in writing.
92M & L for Development of trial bore by reaming in steps viz From 250 mm to 350 mm ; From 350 mm to 450 mm ; From 450 mm to 525 mm; From 525 mm to 675 mm, up to 60 RM from ground level for insertion of casing pipe 350 mm bore for 02 Nos borewell complete all as specified and directed.
93Development of trial bore by reaming in steps viz From 250 mm to 350 mm ; From 350 mm to 450 mm ; From 450 mm to 525 mm, exceeding 60 Rm but not exceeding 100 RM from ground level for insertion of casing pipe/stainer, 250 mm bore, complete all as specified and directed. NOTES: - (a) Depending upon the availability of water bearing strata, if drilling beyond 100.00 Metre is required, the same shall be carried out only after obtaining written approval from PM.
94Supply, lowering and fixing in position 250 mm nominal bore ERW heavy duty MS casing pipe of 7.10 mm wall thickness and welding joints with MS coupler ring around the pipes with MS flat iron 80 mm X 6 mm complete all as specified and directed.
95Supply, lowering and fixing in position 350mm nominal bore ERW heavy duty MS casing pipe of 7.10 mm wall thickness and welding joints with MS coupler ring around the pipes with MS flat iron 80 mm X 6 mm complete all as specified and directed.
96Supply lowering and fixing in position 250 mm bore, 8.00 mm wall thickness, low carbon galvanized steel (LCG) strainer, "V" wired type (inwardly widening to give no clogging property and shall have minimum geometrical resistance to water flow to reduce frictional head losses) , with 1 mm continuous slot to offer not less than 25 % open area, and with bevelled end, conforming to IS 8110:2000 (Reaffirmed 2006), butt jointed by welding in suitable length with MS flat iron 80 X 6 mm coupler ring all around the pipe complete all as specified and directed.
97Supply lowering and fixing in position MS reducing socket 350 mm X 250 mm nominal bore, 8 mm thick and duly welded to pipe with MS flat iron 80 mm X 6 mm coupler ring complete all as specified and directed.
98S & F development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water, including cost of material, labour and T & P as per drawing complete,all as specified and directed.
99Supply and Fix, Bail Plug having 3.00 Metre length, fabricated out of ERW heavy duty MS casing pipe of 7.10 mm wall thickness and suitable for 250 mm bore, including welding joints with MS coupler ring around the pipes with MS flat iron 80 mm X 6 mm, complete all as specified and directed.
100Supplying, pouring and packing pea-gravel of size 3 mm to 8 mm and packed all around the entire bore well to fill in the annular space between pipe assembly and bore hole, complete all as specified and directed.
101Providing water logging test with electro logging equipment and required machinery for ascertaining / logging aquifers encountered in trial bore and arranging and defining the water availability test giving test report of Geo-Hydrologist from Govt. approved laboratory recommending water bearing zones, TDS of water etc., complete all as specified and directed.
102M & L for yield test for bore well by continuous pumping for 15 hrs to determine safe pumping yieldcomplete all as specified and directed.
103Supply, fixing and lowering 100 mm bore MS, column pipe, both end flanged, 3.00 Metre long, fitted with flanges at both ends made out of heavy grade pipes of 5.4 mm wall thickness, ISI Marked (IS: 1239-Part-I), complete with bolts, nuts, gaskets etc. as required complete all as specified and directed.
104Supply and fixing well cap made out of 5 mm thick MS plate with provision of suitable holes for passing through two runs of flat three core, PVC insulated industrial cable for submersible motor, 16.00 Sq. mm and suitable for fixing to 350 mm nominal bore ERW heavy duty MS casing pipe of 8.00 mm wall thickness complete all as specified and directed.
105Supply, installation, testing and commissioning of submersible pump set , electric driven 415 V, 50 Hz, Three Phase, 20 HP, 15 KW, speed 2900 RPM (Sync) , delivery size suitable for 150mm size NRV, having discharge capacity 670 Litres per minute at 75 Metre head, suitable for lowering inside existing casing pipe of bore well (300/350mm) including necessary jointing to existing GI column pipes with flanged joints, with rubber gaskets, nut, bolts & washers of required size, and including electrical connection from starter panel to motor with existing submersible cable, complete all as specified and directed. [Model No :- ‘UPHA 293/4 + HBC 203’ of Make ‘KSB’ or equivalent model of Make ‘Crompton Greaves" / "Calama"]. NOTE:- Column pipe with flanged joints and submersible cable will be measured and paid seperately.
106Materials and Labour for, flat three core, PVC insulated industrial cable for submersible motor, 10.00 Sq. mm (Nominal area) with multi stranded copper conductor, 1100 Volts grade, conforming to IS: 694 all as per product Code No WHPNDSKB3010 of Make ‘Havells’ or equivalent make of Finolex / RR Cable, connected from starter to submersible pump motor, complete all as specified and directed.
107Supply, Installation, testing and commissioning of Chlorine Solution Dosing System (Make of approved list of department and approved by PM) comprising of dosing pump (suitable for chlorine solution prepared from calcium based granules), AC, single phase, 230 Volts, 50 Hz, electrically operated with high starting torque, having positive displacement diaphragm type accurated by a solenoid solid state pulsar, with discharge capacity of 1 to 8 Litres / Hour of standard mixture of calcium based calcium base chlorine granule with water, of any strength and suitable for injecting chemical mixture at 4 to 6 Kg per sq cm pressure, with provision of polypropylene / LDPE suction and discharge pipes of suitable size and length with swing seal foot valve at bottom end of suction pipe, and with 100 Litres capacity FRP tank with FRP Lid having post hole for pouring calcium based chlorine granules and water, including provision for mounting the dosing pump on the lid/wall of FRP tank , provision of Level Gauge, Agitator (1280 to 1400 RPM) with shaft and blade in SS 316 (FRP Coated/Epoxy Coated /Plastic Coated) mounted on tank complete with all accessories required for installation as per Manufacturers instructions including supply of 02 (Two) Years normal maintenance Spares i.e. (i) PVC Pump roller tube – 02 (Two) Nos. (ii) Mixing Blade complete with PVC shaft and pin as per Manufacturers instructions – 02 (Two) Sets. and including making provision of mounting the pump set and provision of PCC foundation for placing the FRP tank, complete all as specified and directed.
108Supply, Installation, testing and commissioning of integrated water treatment plant including all mechanical works, electrical control panel, piping works, interconnection works, civil works in foundations and required components with accessories as per details here in after complete all as specifies and directed. (a)DUAL MEDIA FILTER PLANT. 50 cum/hr capacity for removal of suspended solids, dirt, reduce silt density index, reduce turbidity limit and lower down the parameters upto permissible limits as per IS: 10500, complete with MS epoxy coated vessel as per IS 2825 [Thickness not less than 8mm], with suitable filter media (i) anthracite, iii (quartz sand iv) coarse sand etc. and with suitable common raw water feed pumps, common air compressor, common back washing pumping facility, mechanical, electrical control panel, piping works, pressure guage 10 kg/cm2. Material quality IS: 2062 design IS: 2825 for shell. (b)IRON REMOVAL FILTER PLANT. 50 cum/hr capacity for removal of iron from the raw water and lower down upto permissible limit, complete with MS epoxy coated vessel as per IS 2825 (Thickness not less than 8 mm), with suitable filter media i)sand, ii) gravel, iii) MnO2, iv) Berm etc. and with suitable common air compressor, common back washing pumping facility, mechanical, electrical control panel, piping work, pressure guage 10 kg/cm2. Material quality IS: 2062 design for shell. (c)ACTIVATED CARBON FILTER PLANT. 80 cum/hr capacity for removal of color, smell/odour, free residual chlorine and oil from the raw water and lower down upto permissible limit as per IS:10500, complete with MS epoxy coated vessel as per IS:2825 (Thickness not less than 8 mm), suitable media [(i) Activated carbon with high degree of microporosity etc.] and with suitable common air compressor, common back washing pumping facility, mechanical, electrical control panel, piping works, pressure guage 10 kg/cm2. Material quality IS:2825 for shell. (d)02 (two) Nos [01 working + 01 Standby] best efficient, suitable common raw water feed pumps. (e)Commom air compressor (f)Common back washing pumping facility. (g)All mechanical, electrical, control panel, piping, civil works, pressure gauges, cocks, air vent systems, back washing arrangements with suitable size CI sluice / butterfly valves.
109Supply, install, testing & commissioning of Centrifugal Monoblock Pump set of cast Iron impeller with gland packing coupled with induction moter with ‘F’ Classs insulation and IP 55 protection suitable for 3 phase, 300 to 415 Volts, 2900 RPM, discharge not less than 10 lps at minimum 36 meter head with power rating 7.5 KW and 10 HP, impeller, delivery casing and moter body made of cost iron, pump shaft made of carbon steel, sealing with gland packed. Suitable for suction from pipe of size 50 mm dia and delivery to pipe of size 40 mm dia including of Star delta starter of brand Schneider with single phase preventer and over load protection , with provision of 3 crore 10 Sqmm Flat copper cable from starter pannel to pump set, priming line watering arrangement complete using 20mm dia GL pipe Med grade of length upto 10 RM, gate valve 20mm dia- 10 No with necessary PCC foundation with suitable size of nuts, bolts grouted & washers and complete all as specified and as directed and The ratesare inclusive of testing of pump set installation for satisfactory functioning / running & minimum 2 years warranty complete all as specified and directed. Make:-Kirloskar/Crompton/GE
110Supply and fix fully automatic star delta strarter in sheet steel enclosure, suitable for 20HP motor (30 HP starter)3 phase , 415 V, 50 Hz relay range 13-21 A, coil voltage 360V as as per specified and directed. MAKE:- L & T or equivallent in BCH / Seimens / Abb
111Supply, installation, commissioning andtesting silent diesel engine driven Generating Set50 KVA (40 KW at 0.8 PF) capacity 415 Volts, 3 phase, 4 wire & with includingacoustic weather proof enclosure as per CPCB norms and noise level shall not be exceeding 75 db at a distance of 1 metre from all sides, complete in all respects & comprising the following components. MAKE :- Kirloskar Green / Kirloskar Cummins
112(A) Diesel Engine developing suitable BHP at 1500 RPM conforming to BS 5514/ISO0346series inclusive of the following accessories:-
113(i) Radiator and Radiator fan
114(ii) Spider coupling guard
115(iii)Fly wheel
116(iv)Fly wheel housing complete with starter gear ring and coupling as per manufacturer design.
117(v)Air cleaner dry type.
118(vi) Fuel and lubricant oil filter.
119(vii)By-pass filter
120(viii)Coolant inhibitor
121(ix) Fuel pump DTR type/in line mono block fuel injecting pump.
122(x) Water pump
123(xi) Lub oil pump and inclusive of first filling of lubricant oil & coolant.
124(xii) Electric starter 12 Volts DC as manufacturer"s design.
125(xiii) Battery charging generator (DC alternator)
126(xiv)Industrial silencer
127(xv) Lubricant oil cooler
128(xvi)Flexible pipe for silencer
129(xvii) DC volt meter
130(xviii) Water temperatures gauge, lub oil pressure gauge
131(xix)Speedo meter and Engine running hours meter
132xx)Display for fault
133(xxi)Suitable size of turbo-charger
134(xxii) Shut off coil with safeties for LLOP/HWT.
135(xxiii) Mechanical Governor.
136(xxiv)Maintenance free secondary batteries12 Volts as per manufacture design.
137(xxv) Safeties and indications against Low Lube Oil Pressure & High Coolant Temperature.
138(xxvi) In-line monoblock Fuel Injection Pump with Mechanical Governor and fuel feed pump.
139(xxviii) Engine mounting supports.
140(xxix)Engine control panel consisting of OFF/ON/START keys, Lube Oil Pressure Gauge,
141(xxx)Ammeter, Electric Hour meter.
142(xxxi)Engine Operator/Maintenance & Spare parts Manual.
143(xxxii)Engine Spare parts Manual.
144(xxxiii)Engine Warranty Certificate.
145(xxxiv)Engine test certificate.
146(xxxv) Asbestos Rope
147(B)Alternator:-Synchronous alternator 50 KVA,1500rpm, 415 Volts,50Hz, 3 phase system, brushless type,screen protected revolving filled self excited, self regulated, confirming to IS 4772 of 1992/BS 500.
148(c)AMF panel : AMF Panel shall be of suitable size, factory made, indoor cubical type, front openable, fabricated from CRCA steel sheet 1.6 mm thick complete as per manufacturer specification of Diesel Engine suitablefor DG set of capacity 50 KVA, grouted in floor with PCC 1 :2:4 type B-2 foundation of suitable size as per manufacturer"s recommendations complete in all respects. Cables are ferruled for proper maintenance / checking / wiring of panel. Detachable cable gland plates are provided. The panel will be equipped as follows:
149(i)Contactor MLof suitable capacity
150(ii)Copper bus bar of current rating up to 100 Amp
151(iii)Sensitivity relay set with suitable CTs
152(iv) Electronic latch circuit with tripping indication
153(v) Instantaneous tripping device for complete panel over current 0.5 AMP.
154(vi) Reset facilities for complete protection of AMF Panel
155(vii) Self sequential starting relay unit 12 Volts DC complete with alarm contactor.
156(viii) Electronic timer 220 Volts for main contactor with 1 No. NC auxiliary contacts
157(ix) Electronic timer 220 Volts but for fuel cut operation with 1 No. NC auxiliary contacts.
158(x) Battery charging unit 12/24 Volts 10 Amp complete with digital volt meter & Amp meter.
159(xi) All as per item No-(ix) here in befor but for fuel cut off operation.
160(xii) Electric starter 12 Volts DC as manufacturer"s design.
161(xiii). Digital voltmeter 0-500 volts panel mounting type size 96mm square with selector switch digital
162(xiv) 3 phase electronic energy meter for measuring meter for measuring generated units .
163(xv) Frequency meter digital type
164(xvi) Suitable type of MCCB for main supply/DG Supplyadjustable over load and adjustable short circuit .
165(xvii) The AMF panel shall have by pass arrangement incase failure of bypass AMF panel
166(xviii) Acoustic enclosure with natural air curculation without loss of any power to ventilation fan. The enclosure shall be modular in construction with hinged bolted structure to provide easy dismantling and shall be made out of high quallity CRCAsteel sheet of 1.6mm thick with sufficient accessories for maintenance work openable and lockable door air tight gasket interior lightening arangement of 20W fitting with On / Off switch to meet latest emission norms.
167(xix) Fuel tank of suitable capacity with inlet and outlet connectiions and fuel level indicator as per OEM.
168(xx) Base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti vibration pads to ensure minimum vibration as recommended by manufacturer.
169:Supply install testing and commissioning factory made LT panel boardindoor type (CPRI approved) made out of 3.15 mm thick sheet metal angle iron base frame wisuitable for AC 3 phase 4 wire 50 HZ supply complete panel duly painted with two coats of synthetic enamel paint over a coat of red oxide platform of suitable size with shutter and locking arrangement for each switchgear and busbar of aluminium conductor suitable shape and size for 3 phase rating of 100 amps the follwing switchgear & controls. Incoming :-(a) 3 Phase 4 wire 50 Hz MCCB 4 Pole 415 V 40 Amps -2 Nos.(b)Ammeter 0- 1000 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No(c) Indicating lamps for three phases Qty 1 set of 3 Nos(d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). Outgoing:- (a) 4 pole MCCB 40 Amp, 50 HZ, 415 V, 25 kA -02 nos. (b) DOL Starter - 2 Nos.
170Supply, install, testing & commissioning of Centrifugal Monoblock Pump set of cast Iron impeller with gland packing coupled with induction moter with ‘F’ Classs insulation and IP 55 protection suitable for 3 phase, 300 to 415 Volts, 2900 RPM, discharge not less than 5 lps at minimum 36 meter head with power rating 3.73 KW and 5 HP, impeller, delivery casing and moter body made of cost iron, pump shaft made of carbon steel, sealing with gland packed. Suitable for suction from pipe of size 50 mm dia and delivery to pipe of size 40 mm dia including of Star delta starter of brand Schneider with single phase preventer and over load protection , with provision of 3 crore 10 Sqmm Flat copper cable from starter pannel to pump set, priming line watering arrangement complete using 20mm dia GL pipe Med grade of length upto 10 RM, gate valve 20mm dia- 10 No with necessary PCC foundation with suitable size of nuts, bolts grouted & washers and complete all as specified and as directed and The ratesare inclusive of testing of pump set installation for satisfactory functioning / running & minimum 2 years warranty complete all as specified and directed . Make:-Kirloskar / Crompton / GE
171SEWAGE DISPOSAL
172M&L for loose filling broken sewer bricks / brick bats as in soakage pits / soakage wells complete all as specified and directed.
173M&Lpreparation of newly plastered or unplastered surface and applying two coats of weather proof paint to external surface of wall (Apex ultima) complete all as specified and directed.
174AIR CONDITIONING & REFRIGERATOR :-
175Supply, installation and commissioning BEE 5 star rated , double door Refrigerator of capacity 280 ltr, smart invertor frost free complete with humidity control, smart inverter Compressor, smart connect,Jet Ice, anti bacterial gasketworking on single phase 230V, 50Hz all complete all as specified and directed.
176Supply, installation and commissioning BEE 5 star rated , double door Refrigerator of capacity 220 ltr, smart invertor frost free complete with humidity control, smart inverter Compressor, smart connect,Jet Ice , anti Bacterial gasketworking on single phase 230V, 50Hz complete all as specified and directed.
177Supply, installation and commissioning ofDeep freezer hard top of 150 ltr capacity working on single phase supply i.e 230V,50 Hz having single door, cooling range 18 degree centrigrade to 22 degree centrigrade, including locking arrangement with recess handle for durability, heavy duty castor wheelsat bottom of freezeer with high density puff insulation for better holding time for items kept inside complete all as specified and directed.
178Supply, installation and commissioning Stablizer for automatic operation single phase naturally air cooled indoor type & drsinged for input variation between 170V to 250V with output voltage stablized at 230 V with accuracy of + 2.5% of 1 kVA complete all as specified and directed.
179SOLAR WATER HEATING SYSTEM :-
180Supply & Fixing water Heater (Geyser) , Storage type electric of25 Ltr capacity, BEE 5 Star rating, including fixing on wall with nuts and bolts etc., PVC connection pipe of required length for hot and cold water supply complete all as per specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail