Military Engineer Services-MES has published Tender For Special Repair To Bldg No T-225, T-226, T-252, T-253 And T-290 At 156 Ta Under Age(I) Cif(R). Submission Date for this Tender is 03-01-2024. Building Work Tenders in Rajouri Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

40930362
Corrigendum : Tender For Special Repair To Bldg No T-225, T-226, T-252, T-253 And T-290 At 156 Ta Under Age(I) Cif(R)
Open Tender
Indian
Jammu And Kashmir
Rajouri
03-01-2024

Tender Details

Tender For Special Repair To Bldg No T-225, T-226, T-252, T-253 And T-290 At 156 Ta Under Age ( I ) Cif ( R ) ; 1 Taking Down Chowkhat Or Frame With Shutter ( Without Taking Off Shutter From The Frame ) Exc. 1.50 Sqm But N Exc. 4 Sqm Each All As Specified. 2 Taking Down Chowkhat Or Frame With Shutter ( Without Taking Off Shutter From The Frame ) N Exc. 1.50 Sqm Each Incl Taking Out Hold Fast. 3 Taking Down Shutters Of Any Description Exc 1Sqm But N Exc 2Sqm Each. 4 Pressed Steel Frames Factory Made For Doors Out Of 1.25Mm Thick Pbi Sheet With One Of More Rebates Including Necessary Flat Iron Lugs, Hinges, Lock Strike Plate, Hinges Etc Complete, Size Of Frame 125X60mm Complete All As Specified And Directed 5 Providing, Cement Concrete 1:3:6 ( 20 Mm Graded Aggregate Type C1 ) In Lintels Upto 1.5M Clear Span, Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs And Inside Pressed Steel Door Frame As Directed. 6 S&F 30Mm Thick Plain Framed Panelled Door Shutters Of 2Nd Class Hard Wood ( Factory Made ) Two Panel With Lock Rail And Panel Of 9Mm Thick Bwp Commercial Plyor 12Mm Veneered Particle Board With Commercial Veneering On Both Faces. The Size Of Rail And Stile As Per Is : 1003 Part-I, Kiln Seasoned And Chemically Pressure Treated, Fitted To Chowkats Complete All As Specified And Directed. 7 S&F 30Mm Thick 2Nd Class Hard Wood Plain Framed Factory Made Glazed And Skelton Shutters Open Rebated And Prepared To Receive Glass / Wire Gauge Etc ( Without Sas Bars ) Edges Of Framing Plain, Chamfered Or Rounded, Fitted With Cut And Mitred Beads For Secring Glass, Etc Size Of Members Of Shuters As Specified In Ssr Part-I, Section 8, Clause 8.24 ( A ) All As Specified. 8 Solid Pvc Door Frames Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M S Square Tube, Suppling And Fixing In Opening As Per Specification And Drawing As Per Ssr Pt-Ii 2020, Complete All As Specified And Directed. 9 Factory Made Wood Grain Printed Pvc Door Shutter 30 Mm Thick ( Style ) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottomrails. M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc ‘C’ Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & Asgap Insert For Top Rail & Bottom Rail;Panelling Of Plain Colour Pvc Sheet To Befitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheetbeading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame Atsite As Per Specification & Drawing. 10 S & F 100 Mm Long Butt Hinges, Medium Wight Cold Rolled Mild Steel, Complete All As Specified And Directed. 11 S & F Floor Door Stopper Of Aluminium Alloy Body And Tongue , Anodised , With Hard Drawn Steel Spring , Fixed In Floor , Over All Length Of Cover Plate 140 Mm , Complete All As Specified And Directed. 12 S & F 125 Mm Extruded Aluminium Alloy Handles, Fabricated Type, Anodisedand, Complete All As Specified And Directed. 13 S & F 150 Mm Aluminium Anodised Barrel Tower Bolt Of Extruded Section And Fixed, Complete All As Specified And Directed. 14 S&F Mild Steel Sliding Door Bolts 300Mm Long, Plate Type, Stove Enamelled Black With Bright Bolt Not Less Than 12Mm Dia With And Including A Minimum Of 6 Bolts And Nuts, Four On Bolt Plate And Two On Staple Plate And Fixed, Complete All As Specified. 15 S&F Galvanised Mild Steel Wire Cloth, 0.56Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18Mm And Fixed With Tinned Tacks, Or Galvanised Wire Staples Including Fixing With Beads, Nut Bolts, Welding, Etc Complete All As Specified. 16 Dismantling Of Steel ( Corrugated, Semicorrugated, Etc ) Sheets In Roof Coverings, S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws. Sheet Colour Approved By Engineer-In-Charge Complete All As Specified And Directed. 17 Dismantling Of Steel ( Plain ) Sheets In Roof Coverings, S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550Mpa As In Roof Covering / Cladding / Ridges To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed. 18 Dismantling Of Steel ( Corrugated, Semicorrugated, Etc ) Sheets In Roof Coverings, S&F 0.63 Mm Thick Galvanised, Corrugated Mild Steel Sheeting With Two Corrugations Side Lap, Fixed With Coach Screws And Washers, In Roofs, Walls Etc. With Grade Of Zinc Coating 275 Withl-Type Or J-Type Or Cranked Hook Bolts In Lieu Of Screws, Complete All As Specified. 19 Demolition Of Brick Work / Stone Masonry Built In Cement Mortar Or Cement Lime Mortarincluding All Quoins , Arches , Pillars Etc But Excluding Ashlar Facings, Dressed Stone Work And Precast Concrete Articles, Complete All As Specified And Directed. 20 M&L For Brick Work With Sub Class B Bricks Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And Directed. 21 All As Per Serial Itemno 20 Here In Before But Except Bricksall As Specified And Directed By Engr-In-Charge 22 M&L For Rendering 15Mm Thick On Fair Faces Of Brick Or Concrete Surfaces In Cement Mortar 1:4 On Walls Finished Even And Smooth Complete All As Specified And Directed By Engr-In-Charge. 23 M&L For Preparation Of New Plastered Surfaces And Applying Two Coats Of Cement Base Paint On Walls Complete All As Specified And Directed By Engineer-In-Charge. 24 Material & Labour For One Coat Of Synthetic Paint Including Preparation Of Old Wooden Surface To Match The Shade As Per Colour Scheme As Approved By Engr-In-Charge. 25 S&F 110Mm Bore, Pvc Rainwater ( Swr ) Drainage Pipes Single Socketed, In Any Length With Rubber Ring Joints As Fixed In Repair To Walls / Floor Complete All As Specified And Directed. 26 S&F In Repair 110Mm Bore Pvc ( Swr ) Bends Any Radius Complete All As Specified And Directed. 27 Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For Complete All As Specified And Directed By Engr-In-Charge. 28 M&L For Mild Steel Rolled Work As In Roof Trusses ( Framed ) , Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing ( Beam, Tee, Angle, Channel Or Flat Sections ) Including Distance Pieces, Cleats Etc, Conforming To Grade Fe 410-W, Complete All As Specified And Directed. 29 Prepration Of New Or Previously Steel Surfaces Any Description, Not Otherwise Described Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paintover A Coat Of Red Oxide Primer, Complete All As Specified And Directed. 30 Preparation Of Old Painted Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint / Camouflaged Pattern, Complete All As Specified And Directed. 31 Prepration Of New Wood Or Wooden Based New Or Previously Untreated Surface Of Any Description, Over 10 Cm Width Or Gridth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer, Complete All As Specified And Directed. 32 Demolition Of Cement Concrete ( Unreinforced ) In Ground Floors And Pavings N Exe 15 Cm Thickness. ( Below Or Above Ground Level ) All As Specified. 33 M&L For 75Mm Thick Pcc 1:3:6 Type C-2 ( Using 40Mm Graded Crushed Stone Aggregate ) As In Plinth Protection Finished Even And Fiar Without Using Extra Cement, Complete All As Specified And As Directed. 34 M&L 75Mm Thick Plain Cement Concrete Type D-2, 1:4:8 ( Using 40Mm Graded Crushed Stone Aggregate ) As In Sub Base All As Spd And Directed. 35 M&L For 20 - 25 Mm Thick Cement Concrete Chequred Tiles 30Cm X 30 Cm, Machine Pressed, Set, Jointed And Pointed In Neat Cement Slurry In Floors With Grey Cement And Pigment Over 15 Mm Thick Screed Bed In Cm 1:6 Complete All As Specified. 36 M&L For Machine Pressed Precast Concreteinterlocking Pavor Block Any Shape And Size Conforming To Is 15658-2006 Of 60 Mm Thick M-35 Grade, Complete All As Specified And Directed. 37 M&L For Sand Filling Under Interlocking Pavor Block Including Watering And Consolidation, Complete All As Specified And Directed. 38 Demolition Of Precast Concrete Articles Such As Jafri Wall , Built Incementmortar All As Specified And Directed. 39 Providing Precast Cement Concrete Louvers And Jallies 25Mm Thick ( Measures Solid ) , 1:3:6 Type C-0 Using 12.5Mm Aggregate, Including All Moulding But Excluding Frame, Fixed In Cement Mortar 1:4 Complete, All As Specified. 40 S&F In Repair Stainless Steel Curtain Rods 20 Mm Dia Including Brackets With Cut Hole Suitable For 20 Mm Dia Rod Fixed With Screws And Gutties In Wall, Including End Caps With Wall Ornament And Fixed To Curtain Rod With Screws Of Design / Shapeall As Directed And As Approved By Engr In Charge. 41 Demolition Of Cement Concrete ( Reinforced ) Of Any Description And In Any Position Not Otherwise Specifically Providedfor Complete All As Specified. 42 Mild Steel Tmt Bars 10 Mm Dia And Over In Reinforcement, Cut To Length, Bent To Shape Required Including Cranking, Bending Spirally Or Hooping For Columns, Hooking Ends And Binding With Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia, Completeall As Specified And Directed. 43 Tmtsteel Bars 5 Mm Dia And Over Upto And Including 10 Mm Dia In Stirrups , Spacers And Binders Cut To Length, Bent To Shape Required Including Cranking, Bending Spirally Or Hooping For Columns, Hooking Ends And Binding With Ms Wire ( Annealed Not Less Than 0.9Mm Dia ) All As Specified And Directed. 44 Use And Waste Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Contilevers, Shelves Including Supports, Overhangs, Etc.Also Splays Between Floors And Beams, Etc. Rough Furnished Surface Of Concrete Complete Flat, All As Specified. 45 M&L For Reinforced Cement Concrete ( Nominal Mix M-25 ) In Roof Beams, Cantilevers, Bressummers, Lintels Over 1.5M Span, Complete All As Specified And Directed By Engr-In-Charge. 46 M & L For Pcc ( 1:4:8 ) Type D2 Using 40 Mm Graded Stone Aggregate For Base Foundationof Poleall As Specified And As Directed By Engineer-In-Charge. 47 M&L For Cement Concrete Type C-1 1:3:6 ( 20Mm Graded Stone Aggregate ) In Surface Channels And Drains Including Necessary Formworkcomplete All As Specified. 48 Extra For Forming Fair Finished Drain Or Channel 30Cm Inner Girth In Cement Concrete, Using Extra Cement, Including Forms, Moulds, Mitred / Stopped Ends Etc Complete All As Specified And Directed By Engr-In-Charge. 49 Dismantling Of Wall And Ceiling Boards Of Any Thickness Incl Cover Fillets Etc And S&Fpvc Wall Lining Consisting Of 5Mm Thick Plain Colour Pvc Sheetas In Striups And Chanel Inclusive Of Solvent Cement And Fixing At Site On Necessary Pvc Frame Incl Fillets As Per Specifications And Drawings 50 S&F In Position Suspended False Ceiling System Using E-Grid Suspended Ceiling Grid System. The Size Of Grid Shall Be 600 X 600Mm With Gi Frame Work Main Runner 38 X 24Mm Cross Tee 25 X 24Mm And Wall Angle 24X24mm, Using 4 Mm Thick Ceiling Panel Laminated With Pvc Film On Front Face And Foil Back Availabel In Due Drop Texture As Per Is-2095, Part-I-1996, Fixid In The Grid Of E-Grid Suspended Ceiling Grid System Duly Suspended By 4Mm Dia Gi Bar Hanger From The Purlins Of The Roof With Butter Fly Clips All As Directed And As Approved By Engr In Charge And Dismantling Wall And Ceiling Board ( Fibre, Pulp, Insulation Etc ) Or Insulation Boards / Slabs / Blankets Any Thickness Including Fillets, Complete All As Specified And Directed By Engineer-In Charge. 51 S&F Cast Iron Door Closer Hydraulically Regulated Desination No 1 Universal Type Suaitable For Door Shutter Up To 1000 Mm In Width And Of Weight Not More Then 35 Kg, Completeall As Specified And As Directed. 52 S & F, Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Complete All As Specified And Directed. 53 S&F, Anodised Aluminium Door Shutters, Aluminium Section Weighing 0.55 Kg / M Including Necessary Joining Cleats, Glazing Clips, Ruber Neoprene Packing, Handles 2 Nos In Each Door, Hinges, Anodised Aluminum Snap Beading Screws Including 5.5Mm Thick Tinted Glass Or 9 Mm Thick Pvc Sheet Best Quality And Cylindrical Lock Including Rubber Gasket & Neospreme Lining Complete All As Specified And Directed. 54 S&F, Anodised Aluminium Window And Ventilator Shutters, Side Hung Type Without Sash Bars, Aluminium Sections Weighing 0.55 Kg / M Including Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws, Anodised Aluminium Fittings Such As Peg Stays 150Mm Long ( 1 No. ) . Hinges Type B-21100Mm Long ( 2 No. ) Suitable Handle ( 1 No. ) , 5.5Mm Thick Tinted Sheet Glass Including Neospreme Lining And Rubber Gasketc Complete All As Specified And Directed. 55 Dismantling Of Floor Tiling Incl Cement Mortar Bedding ( But Not Backing ) Removing Servicable Tiles To A Store And Rubbish Off Premises, M&L Non Skidceramic Coloured Tiles7 To 8Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Colour Of Tiles Laid Over And Including 15Mm Thick Screed Bed In Cm 1:6 Complete All As Specified And Directed. 56 Taking Down Carefully Copper / Aluminium Point Wiring ( Light / Fan Socket Or Power ) With Complete Fittings Such As Switch, Sockets Ceiling Rose Pendent Holders Regulators Etc.Removing Old / Unsv Material From Site And Making Good The Old Disturbed Surface. 57 M&L For Point Wiring Complete With 1.5 Sqmm Single Core Multi Stranded Copper Conductor Cable Pvc Insulated Unsheathed Cable 1100 Volt Grade Enclosed And Including Pvc Casing And Capping With Fittings And Accessories Fixed To Walls / Ceiling By Means Of Pvc Rowl Plugs Fasteners With Cadmium Plated Screws All As Per Is Including Hard Wood Board Pvc Board And 3Mm Thick Laminated Sheet Top Covers Including 1.5 Sqmm Copper Pvc Insulated Unsheathed Continuous Earth Wire And Connected To Common Earth Dolly For The Following:- 58 One Light / Fan Point Controlled By One Switch 5 Amp. 59 One Bell Point5 Amp Controlled By One Bell Push On Independent Board. 60 One Socket Outlet 5Amp Controlled By One Switch On Same Board. 61 All As Per Item No 57.00 Here In Before But Point Wiring With 2.5 Sqmm Fr Multi Stranded Copper Conductor Cable For Main Circuit And 2.5 Sqmm Cable As Earth Continuity Conductor For One 15 Amp Socket Out Let Controlled By One 15 Amp Switch On Independat Board, Complete All As Specified And Directed. 62 Supply And Fixing Of Modular Switch Single Pole One Way6 Amps 1 Module Complete All As Specified And Directed 63 S&F Of Modularsocket 6 A-2 / 3 Pin Combined 2 Module Complete All As Specified And Directed. 64 Supply And Fixing Of Modular Switch Single Pole One Way 16 Amps 1 Module Complete All As Specified And Directed 65 M&L In Replacementof Modularsocket 6 A / 16 Amp -3 / 5 Pin Combined 2 Module Complete All As Specified And Directed. 66 S&F Ofceiling Rose, Surface Bakelite 65X50mm Three Terminals Pvc / Polycarbonate Complete All As Specified And As Directed 67 Supply And Fixing Fan Regulator, Electronic Step Type Heavy Duty Modular 2 Module 230 Volts, 120 Watt Complete All As Specified And As Directed. 68 Material And Fixing Of Pvc Lamp Holder Insulated Body Of Bakelite With Back Plate Batten / Angle Type For Batten Fitting Complete All As Specified. 69 Supply And Fixing In Replacement Led Bulbs White / Warm White ( As Per Demand ) In Colour Of 12 Watt, B-22 Base Cap, Complete All As Specified And Directed. 70 S & F In Replacement Led Light Fitting 1X9w / 1X10w Bulkhead Luminaires Including Led Light Driver Holder Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size, Complete All As Specified And Directed. 71 S&F In Replacement Led Tubelight Fitting 1X20wattbattentype Fitting4 Feetlong Aluminium Extruded Housingip-20 Ratedrated Voltage 230 Volts ( Operating Range 140 Volt To 270 Volts ) , 50Hzsystem Wattage 20 Watt + / -10% , System Current Not Less Than 102 Ma , Power Factor More Than 0.95, Systemlumen Efficacy 100 Lm / Watt , Cct 6500Kcri More Than 80, Thd Less Than 30%, Driver Efficiencymore Than 85% Complete All Accessories Prewired And Connecting Electrically To Ceiling Rose Using Pvc Insulatedand Overallsheathedflexible Copper Conductor Of Size 0.75 Sqmm3 Core All As Specidfierd And Directed. 72 Supply And Fixing In Replacement Of Sheet Metal Enclosuremcb Distribution Board Spn 8 Way230 V, 50 Hz Double Doorwith Neutral, Earthing Bar And Din Rail, Complete All As Specified And Directed. 73 Supply And Fixing In Replacementof Mcb Single Pole 6 To 30 Amps, 10Ka, 230 Volts C Series, Complete All As Specified And Directed. 74 Supply And Fixing In Replacementof Mcb Spn 40 To 63 Amps, 10Ka, 230 Volts C Series, Complete All As Specified And Directed. 75 M&L For Earthing Complete For Bldgwith Galvanized Mild Steel Earth Plate Electrode 60Cm X 60Cm X 6Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Meters Below Ground Level ) With Top Edge Of Earth Plate Not Less Than 1.5 Meters Below Ground Level Connected To Galvanized Earth Wire 4.00 Mm Diaby Means Of Nuts, Bolts, Thimbles, Chuck Nuts, Washers Of Gi Or Steel, Pcc ( Concrete Chamber Of Size 300 Mm X 300 Mm X 300 Mm Inside Dimension ) Shall Be Pcc 1:3:6 Type C-1 Using 20Mm Graded Stone Aggregate With Fair Finish , Internal Surface Of Concrete Chamber Shall Be Given 15Mm Thick Plaster In Cm 1:4, Funnel With Wire Mesh Of 22 Gauge, 80 Mm Thick Pcc Pit Cover 320 Mm X 320 Mm Of Rcc 1:2:4 Type B-1 Using 20 Mm Graded Stone Aggregate Reinforced With Xpm, Jalli Pit Shall Be Filled Withcharcoal Dust And Common Salt All As Shown In Electrical Plate No 3 Of Mes Ssr Part-I ( 2009 ) As Specified Includingprovision Of 15Mm Dia Medium Grade Gi Pipe For Earth Wire Protection And 20 Mm Dia For Watering Complete , All Excavation Andearth Work & Connecting The Earthing To An Earthing Test Point / Main Switch Board As Specified And Testing On Completion, Complete All As Specified And Directed. 76 M&L Gi Earth Wire Size 04 Mm As Earth Continuty Conductor. 77 M&L Of Sub Main Wiring With Two Run Of Single Core Pvc Insulated Frlsh Stranded Copper Conductor Cable Of Size 4 Sq Mm And One Run Of 4 Sq Mm Pvc Insulated Frlsh Copper Conductor Cable As Earth Continuity Conductordrawn In And Including Pvc Casing And Caping With Necessary Accessories Complete All As Directed. Note : 2 Runs Of 4 Sqmm Cable And One Run Of 4.00 Sqmm Earth Wire With Pvc Rigid Conduit Shall Be Measured As On Length. 78 Excavation In Trenches In Any Type Of Soil Not Exc 1.5M Wide And N.Exc 1.5M In Depth For Electric Poles Stay Foundation And Under Ground Electric Power Cables And Getting Out, Complete All As Specified And Directed. 79 Sand Cushioning With Fine Sand To Under Ground Cables In Trenches / Ducts In Layers Of 8 Cm Deep Before Laying The Cable And 15 Cm Deep After Laying And Stretching The Cable As Specified In Clause 19.75 Of Ssr Part-I, Complete All As Specified And Directed By Engr-In-Charge. 80 Supply, Laying, Jointing And Testingxlpe Insulated Pvc Sheathed Armoured Under Ground Cable Heavy Duty With Aluminium Conductor Lt 1100 V Grade Cross Sectional Area16 Sqmm 4 Core Including Taking Down Old Cable, Complete All As Specified And Directed By Engineer-In-Charge. 81 M&L For Brick Covering With Width Equal To Length Of Brick As Mechanical Protection To Cables With Well Burnt Sub Class ‘B’ ( Old Size ) Bricks Laid Dry Flat, Complete All As Specified And Directed. 82 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers N. Exc 25 Cm In Any Type Of Soil Complete All As Specified And Directed. 83 Removing Surplus Spoil To A Distance Not Exceeding 50M And Deposited Where Directed At A Level Not Exceeding 1.50M From The Starting Point., All As Specified . 84 Steel Tubing Galvanized ( Light Grade ) 40 Mm Bore Conforming To Is-1239 Forpassing Cable Under Road / Floor Or Fixing To Poles For Protection Of Under Ground Cable Complete With Flat Iron 50X6mm Clampsmade To Shape And 12Mm Dia Bolts, Nuts And Washers For Fixing Where Required Complete All As Directed By Engr-In-Charge 85 Deduction To Be Made From Boq For Schedule Of Credit ( Sch A Part - Ii ) Amount Of ? 35, 205.00During Aocnote:- Tenderers Shall Not Quote For This Schedule

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 40940.0 /-
Tender Value
INR 20.47 Lakhs /-

BOQ Items

Name of Work: SPL REPAIR TO BLDG NO T-225, T-226, T-252, T-253 AND T-290 AT 156 TA UNDER AGE(I) CIF(R)
Sl. No. Item Description
1Taking down chowkhat or frame with shutter (without taking off shutter from the frame)exc. 1.50 Sqm but n exc. 4 Sqm each all as specified.
2Taking down chowkhat or frame with shutter (without taking off shutter from the frame) n exc. 1.50 Sqm each incl taking out hold fast.
3Taking down shutters of any description exc 1Sqm but n exc 2Sqm each.
4Pressed steel frames factory made for doors out of 1.25mm thick PBI sheet with one of more rebates including necessary flat iron lugs, hinges, lock strike plate, hinges etc complete, size of frame 125x60mm complete all as specified and directed
5Providing, cement concrete 1:3:6 (20 mm graded aggregate type C1) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs and inside pressed steel door frame as directed.
6S&F 30mm thick plain framed panelled door shutters of 2nd class hard wood (Factory made) two panel with lock rail and panel of 9mm thick BWP commercial plyor 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 Part-I, Kiln seasoned and chemically pressure treated, fitted to chowkats complete all as specified and directed.
7S&F 30mm thick 2nd class hard wood plain framed factory made glazed and skelton shutters open rebated and prepared to receive glass/ wire gauge etc (without sas bars)edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for secring glass,etc size of members of shuters as specified in SSR Part-I,Section 8, clause 8.24 (a) all as specified.
8Solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M S square tube, suppling and fixing in opening as per specification and drawing as per SSR Pt-II 2020, complete all as specified and directed.
9Factory made wood grain printed PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottomrails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail & bottom rail on either side & asgap insert for top rail & bottom rail;Panelling of plain colour PVC sheet to befitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheetbeading, and joined together with solvent cement, suppling & fixing in the frame atsite as per specification & drawing.
10S & F 100 mm long butt hinges, medium wight cold rolled mild steel, complete all as specified and directed.
11S & F Floor door stopper of aluminium alloy body and tongue , anodised , with hard drawn steel spring , fixed in floor , over all length of cover plate 140 mm , complete all as specified and directed.
12S & F 125 mm extruded aluminium alloy handles, fabricated type, anodisedand, complete all as specified and directed.
13S & F 150 mm aluminium anodised barrel tower bolt of extruded section and fixed,complete all as specified and directed.
14S&F mild steel sliding door bolts 300mm long, plate type, stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified.
15S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples including fixing with beads, nut bolts, welding, etc complete all as specified.
16Dismantling of steel (Corrugated, semicorrugated, etc) sheets in roof coverings, S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws. Sheet colour approved by Engineer-in-Charge complete all as specified and directed.
17Dismantling of steel (plain) sheets in roof coverings, S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding/ridges to wall, fixed with self tapping screws complete all as specified and directed.
18Dismantling of steel (Corrugated, semicorrugated, etc) sheets in roof coverings, S&F 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 withL-type or J-type or cranked hook bolts in lieu of screws, complete all as specified.
19Demolition of brick work / stone masonry built in cement mortar or cement lime mortarincluding all quoins ,arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and directed.
20M&L for brick work with sub class "B" bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6, complete all as specified and directed.
21All as per serial itemNo 20 here in before but except bricksall as specified and directed by Engr-in-Charge
22M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls finished even and smooth complete all as specified and directed by engr-in-charge.
23M&L for preparation of new plastered surfaces and applying two coats of cement base paint on walls complete all as specified and directed by Engineer-in-charge.
24Material & labour for one coat of synthetic paint including preparation of old wooden surface to match the shade as per colour scheme as approved by Engr-in-Charge.
25S&F 110mm bore, PVC rainwater (SWR) drainage pipes single socketed, in any length with rubber ring joints as fixed in repair to walls/floor complete all as specified and directed.
26S&F in repair 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
27Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by engr-in-charge.
28M&L for mild steel rolled work as in roof trusses ( framed) , trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing( Beam, tee, angle, channel or flat sections ) including distance pieces, cleats etc, conforming to grade Fe 410-W, complete all as specified and directed.
29Prepration of new or previously steel surfaces any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paintover a coat of red oxide primer, complete all as specified and directed.
30Preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint/camouflaged pattern, complete all as specified and directed.
31Prepration of new wood or wooden based new or previously untreated surface of any description, over 10 cm width or gridth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
32Demolition of cement concrete ( unreinforced) in ground floors and pavings n exe 15 cm thickness. ( below or above ground level) all as specified.
33M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection finished even and fiar without using extra cement, complete all as specified and as directed.
34M&L 75mm thick plain cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) as in Sub base all as spd and directed.
35M&L for 20 - 25 mm thick cement concrete chequred tiles 30cm x 30 cm, machine pressed,set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over 15 mm thick screed bed in CM 1:6 complete all as specified.
36M&L for Machine pressed precast concreteinterlocking pavor block any shape and size conforming to IS 15658-2006 of 60 mm thick M-35 grade, complete all as specified and directed.
37M&L for sand filling under interlocking pavor block including watering and consolidation, complete all as specified and directed.
38Demolition of precast concrete articles such as jafri wall , built incementmortar all as specified and directed.
39Providing precast cement concrete louvers and jallies 25mm thick (measures solid), 1:3:6 type C-0 using 12.5mm aggregate, including all moulding but excluding frame, fixed in cement mortar 1:4 complete, all as specified.
40S&F in repair stainless steel curtain rods 20 mm dia including brackets with cut hole suitable for 20 mm dia rod fixed with screws and gutties in wall, including end caps with wall ornament and fixed to curtain rod with screws of design/shapeall as directed and as approved by Engr in Charge.
41Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically providedfor complete all as specified.
42Mild Steel TMT bars 10 mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia, completeall as specified and directed.
43TMTsteel bars 5 mm dia and over upto and including 10 mm dia in stirrups , spacers and binders cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified and directed.
44Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, contilevers, shelves including supports, overhangs, etc.also splays between floors and beams, etc. rough furnished surface of concrete complete flat, all as specified.
45M&L for reinforced cement concrete (nominal mix M-25)in roof beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed by engr-in-charge.
46M & L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate for base foundationof poleall as specified and as directed by Engineer-in-Charge.
47M&L for cement concrete type C-1 1:3:6 (20mm graded stone aggregate) in surface channels and drains including necessary formworkcomplete all as specified.
48Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed by engr-in-charge.
49Dismantling of wall and ceiling boards of any thickness incl cover fillets etc and S&FPVC Wall lining consisting of 5mm thick plain colour PVC sheetas in striups and chanel inclusive of solvent cement and fixing at site on necessary pvc frame incl fillets as per specifications and drawings
50S&F in position suspended false ceiling system using E-grid suspended ceiling grid system. The size of grid shall be 600 x 600mm with GI frame work main runner 38 x 24mm cross tee 25 x 24mm and wall angle 24x24mm, using 4 mm thick ceiling panel laminated with PVC film on front face and foil back availabel in due drop texture as per IS-2095, part-I-1996, fixid in the grid of E-grid suspended ceiling grid system duly suspended by 4mm dia GI bar hanger from the purlins of the roof with butter fly clips all as directed and as approved by Engr in Charge and dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including fillets,Complete all as specified and directed by Engineer-in Charge.
51S&F Cast Iron door closer hydraulically regulated desination No 1 universal type suaitable for door shutter up to 1000 mm in width and of weight not more then 35 kg, completeall as specified and as directed.
52S & F, Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
53S&F, Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws including 5.5mm thick tinted glass or 9 mm thick PVC sheet best quality and cylindrical lock including rubber gasket & neospreme lining complete all as specified and directed.
54S&F, Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.), 5.5mm thick tinted sheet glass including neospreme lining and rubber gasketc complete all as specified and directed.
55Dismantling of floor tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L non skidceramic coloured tiles7 to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
56Taking down carefully copper/aluminium point wiring (light/Fan socket or power) with complete fittings such as switch, sockets Ceiling rose pendent holders regulators etc.Removing old/UNSV material from site and making good the old disturbed surface.
57M&L for Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor cable PVC insulated unsheathed cable 1100 volt grade enclosed and including PVC casing and capping with fittings and accessories fixed to walls/ceiling by means of PVC rowl plugs fasteners with cadmium plated screws all as per IS including hard wood board PVC board and 3mm thick laminated sheet top covers including 1.5 Sqmm copper PVC insulated unsheathed continuous earth wire and connected to common earth dolly for the following:-
58One light/fan point controlled by one switch 5 Amp.
59One bell point5 Amp controlled by one bell push on independent board.
60One socket outlet 5Amp controlled by one switch on same board.
61All as per item No 57.00 here in before but point wiring with 2.5 sqmm FR multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board, complete all as specified and directed.
62Supply and fixing of modular switch single pole one way6 Amps 1 module complete all as specified and directed
63S&F of modularsocket 6 A-2/3 pin combined 2 module complete all as specified and directed.
64Supply and fixing of modular switch single pole one way 16 Amps 1 module complete all as specified and directed
65M&L in replacementof modularsocket 6 A/16 amp -3/5 pin combined 2 module complete all as specified and directed.
66S&F ofceiling rose, surface bakelite 65x50mm three terminals PVC/Polycarbonate complete all as specified and as directed
67Supply and Fixing fan regulator, electronic step type heavy duty modular 2 module 230 volts,120 watt complete all as specified and as directed.
68Material and fixing of PVC lamp holder insulated body of bakelite with back plate batten/angle type for batten fitting complete all as specified.
69Supply and fixing in replacement LED Bulbs white /warm white (as per demand) in colour of 12 Watt,B-22 base Cap, complete all as specified and directed.
70S & F in replacement LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
71S&F in replacement LED tubelight fitting 1x20Wattbattentype fitting4 feetlong aluminium extruded housingIP-20 ratedrated voltage 230 volts(operating range 140 volt to 270 volts) , 50Hzsystem wattage 20 Watt +/-10% ,system current not less than 102 mA ,power factor more than 0.95, systemlumen efficacy 100 lm /watt ,CCT 6500KCRI more than 80, THD less than 30%, driver efficiencymore than 85% complete all accessories prewired and connecting electrically to ceiling rose using PVC insulatedand overallsheathedflexible copper conductor of size 0.75 sqmm3 core all as specidfierd and directed.
72Supply and fixing in replacement of sheet metal enclosureMCB distribution board SPN 8 way230 V, 50 Hz double doorwith neutral, Earthing bar and din rail, complete all as specified and directed.
73Supply and fixing in replacementof MCB single pole 6 to 30 Amps, 10KA, 230 volts "C" series, complete all as specified and directed.
74Supply and fixing in replacementof MCB SPN 40 to 63 Amps, 10KA, 230 volts "C" series, complete all as specified and directed.
75M&L for earthing complete for bldgwith galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm diaby means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel,PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish ,internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge,80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled withcharcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified includingprovision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete ,all excavation andearth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion, complete all as specified and directed.
76M&L GI Earth wire size 04 mm as earth continuty conductor.
77M&L of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductordrawn in and including PVC casing and caping with necessary accessories complete all as directed. Note : 2 Runs of 4 sqmm cable and one run of 4.00 sqmm earth wire with PVC rigid conduit shall be measured as on length.
78Excavation in trenches in any type of soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out, complete all as specified and directed.
79Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge.
80Supply,laying, jointing and testingXLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area16 Sqmm 4 core including taking down old cable, complete all as specified and directed by Engineer-in-Charge.
81M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
82Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in any type of soil complete all as specified and directed.
83Removing surplus spoil to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50m from the starting point., all as specified .
84Steel tubing galvanized (light grade) 40 mm bore conforming to IS-1239 forpassing cable under road/floor or fixing to poles for protection of under ground cable complete with Flat iron 50x6mm clampsmade to shape and 12mm dia bolts, nuts and washers for fixing where required complete all as directed by Engr-in-Charge
85Deduction to be made from BOQ for schedule of credit (Sch "A" Part - II) Amount of ? 35,205.00during AOC Note:- Tenderers shall not quote for this Schedule