Tender For Redevelopment Of Panchubarahi Temple, Rajnagar In The District Of Kendrapara For The Year 2023-24, Kendrapara-Odisha

Road And Building Department-RBD has published Tender For Redevelopment Of Panchubarahi Temple, Rajnagar In The District Of Kendrapara For The Year 2023-24. Submission Date for this Tender is 16-12-2023. Building Work Tenders in Kendrapara Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

40917973
Tender For Redevelopment Of Panchubarahi Temple, Rajnagar In The District Of Kendrapara For The Year 2023-24
National Competitive Bid
Indian
Odisha
Kendrapara
16-12-2023

Tender Details

Redevelopment Of Panchubarahi Temple, Rajnagar In The District Of Kendrapara For The Year 2023-24 Building Work

Key Value

Document Fees
INR 10000 /-
EMD
INR 342300.0 /-
Tender Value
INR 3.42 Crore /-

BOQ Items

Name of Work: Redevelopment of Panchubarahi Temple, Rajnagar in the district of Kendrapara for the year 2023-24
Sl. No. Item Description
1CIVIL WORKS(PART-I) Earth work in excavation of foundation in all kind of soil including dressing and levelling the beds within 50m. initial lead and 1.5m. initial lift with cost, conveyance, taxes as per specification and directionof Engineer in charge
2Earth work in Extra lift within 50m. initial lead and 1.5m. initial lift with cost, conveyance, taxes as per specification and directionof Engineer in charge
3Filling foundation and plinth with excavated earth includin cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge
4Filling foundation and plinth with good quality river sand with watering and ramming incluing cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge
5Cement concrete (1:3:6) in foundation and plinth using 4cmsize hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge
6Cement concrete (1:2:4) in foundation and plinth using 12mm ize hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGF
7Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Foundation and Plinth for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor
8Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Superstructure and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor
91st floor
10Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:4) after immersing the bricks for six hours in water before use in Superstructure and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor
11RCC work ofM-25 with 20mm and down graded size crushed stone aggregates mixed by concrete mixer, laying in layers and compacting by vibrator & all leads and lifts including frame works including cost, conveyance, cost of all labour, T&P, cost of all materials etc. complete as per direction and specification of Engineer-in-charge. Footing, Foundation and Plinth
12Plinth Beam
13Column GF
141st floor
15Roof Beam GF
16LintelGF
17Roof slab GF
18Wall GF and Fin
191st floor
20Chajja GF
21Construction of single under reamed bored compaction pile foundation of 300mm dia and 6.0mlongwith RCC M-25 using crushed broken hard granite chips of 20mm and down graded with required design with cost conveyance taxes cost of all materials and labour etc complete as per specification and direction of Engineer in charge
22Exra 0.5 mtr depth
23375mm dia 6.00 mtr long
24Extra 0.5 mtr depth
25Cutting, straightening coiled or bent up M.S. Rod or tor steel using SAIL/RINL/TATA/JINDAL STEEL/ SHYAM STEEL includingbending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge Ground floor
261st floor
27Providing 2.5cm thick grading concrete of prop.(1:2:2) using 6mm size H.G. chips of approved quality & from approved quarry including watering, curing withcost, conveyances, taxes of all materials, cost of all labour, T&P required for the work etc. complete as per direction of Engineer-in-charge iGF
281st floor
29Providing 16mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to outside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor)
301st floor
31Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to inside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor)
32Providing 6mm thick cement plaster in cement mortar (1:4) in all floors finished smooth to inside ceiling surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor)
33Supplyingfitting and fixing of Kotatiles of minimum 16mm thick (above 0.1 sqm) in floors of over 20mm thick bed of cement mortar(1:4)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGF
34Supplyingfitting and fixing of Kotatiles of minimum16mmthick(above 0.1 sqm) in dadoes over 12mm thick bed of cement mortar(1:3)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGF
35Supplying,fitting and fixing of Vitrified tiles of size 600x600mm (coloured/printed) series Homogenous over 20mm thick bed of cement mortar(1:4)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGF
36Supplying,fitting and fixing of Vitrifiedtilesof size 600x600mm coloured/printed series Homogenous in dadoes over 12mm thick bed of cement mortar(1:3)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGF
37Supplyingfitting and fixing of Antiskid Ceramic floor tileover 20mm thick bed of cement mortar(1:4)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGF
38Supplyingfitting and fixing of Ceramic glazed wall tile in dados, skirting and riserover 12mm thick bed of cement mortar(1:3)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGF
39Supplying, fitting & fixing ofGI Grills gate/ door/ window made out of GI square bar, GI angles, GI flats, GI plate, seat etc. with all cutting, fixing with all fabrication work etc. complete as per specification and direction of Engineer in charge
40Providing, Fitting & Fixing of Stainless steel of 304 grade in handrailing of 50mm diaof 2mm thick circular pipewith balustrade of size 32mmX32mm X2mm @ 0.90mtr. C/C and stainlesssquare pipes bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost, conveyance ofMaterials, Labour, TandP etc required for the complete in all respect and as per specification & direction of Engineer-in-charge
41Providing and Painting with two coats of anti-flungal water bound Weather Coat with a coat of primer of approved quality, make and shade to give an even surface including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete as per the direction of Engineer-in-charge GF
421st floor
43Painting two coats with approved Plastic Emulsion paints over putty and a coat of primer of approved quality including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour TandP etc complete as per specification and direction of Engineer in charge GF
44Finishing walls with water proofing cement paint two coats over a coat of cement washing including cost, conveyance, cost of all labour, T&P, cost of all materials etc. complete as per direction and specification of Engineer-in-charge
45Painting two coats with approved Synthetic enamel paints of approved colour, shade over a coat of primer in Iron work including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour TandP etc complete as per specification and direction of Engineer in charge GF
46Construction of cement concrete kerb with Top and Bottom width 115 and 165mm respectively, 250mm high in M20 grade PCC on M10 grade foundation 150mm thick, foundation having 50mm protection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as Clause 408 of MORTH Specification for Road and Bridge work(5th Revision)
47Providing and laying 60mm thick M-30 grade factory made cement concrete interlocking paver block of approved colour, design and pattern laid over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete including cost, conveyance, taxes of all materials, T&P, labour, etc. as per direction of Engineer-in-Charge.
48Supplying and Providing of 32mm thick flush door shutters with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved desig and quality with cost of materials and labour etc complete as per specification and direction of Engineer in charge In all floors
49Supplying and Providing of 34mm thick flush door shutters with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved desig and quality with cost of materials and labour etc complete as per specification and direction of Engineer in charge In all floors
50Providing and fixing of factory made single extruded WPC door frame with Rebate cuts with finished cross section size 75x45mm or 90x50mm of approved quality including cost, conveyance etc complete as per specification and direction of Engineer in charge
51Providing, fitting & fixing Factory made FRP (alternately called GRP) Door frame of size 75mm x 100 mm, fabricated using E-Glass Chopped strand Mat (CSM), U.V. stabilized Isopthalic Gelcoat and impregnated with Isophthalic resin.The thickness of the GRP skin shall not be less than 2.0mm.The door frame consist of four segments, which are provided with plug-in-socket arrangement in-situ in the mould.The segments are plugged in and are joined together by means of screw.The GRP frame shall be provided with wooden reinforcement on six locations for high screw holding capacity for fixing metallic hold fast and shall be consolidated by filling with medium density foam/plaster of paris with fibre reinforcement.Six numbers of 260mm x 25mm x 5mm size ‘S’ shaped M.S. flat hold fast shall be provided with the frame.The material and process for manufacturing the door frames shall conform to RV-TIFAC composites Design Centre’s Standards and specifications
52Providing, fitting & fixing of Factory made single leaf rigid FRP (alternately called GRP) sandwich composite door shutter of 32 mm thick, laminated with two GRP skins with wood grain finish, fabricated using UV-stabilized Isopthalic Gelcoat and one layer of 450 gsm. E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic, polyester resin. The thickness of the skins shall not be less than 1.5 mm. Expanded Polystyrene (EPS) structural foam panel of 29 mm thickness and a density of 20 kg/Cu.mtr. shall be used as core material.Wooden reinforcements made of seasoned Sal Wood block of cross section not less than 28mm x 32mm and also necessary sal wood reinforcements for fixing the metal fittings such as tower bolts, aldrops, handles, etc. shall be provided.A structural adhesive compatible with EPS) foam shall be used for bending the core material, the sal wood reinforcements and the skins.The material and process for manufacturing the door shutters shall confirm to RV-TIFAC composites Design Centre’s standards and specifications and the door shutters tested in confirmation to IS 4020-1998.The finish of door shutter will be plain colour white/Ivory/Beige/Light grey/Mahogany/Teak wood or any other colour using high quality pigments. All FRP materials for use must be procured from registered manufacturing agencies under EPM contracts etc. after conducting/collecting necessary strength tests report as per required specification and relevant codal practice.
53Supplying and fitting fixing of Un-plasticized Poly Vinyl Chloride (UPVC) (FENESTA/NICL/VEKA LTD) Three track Three panel Sliding Window-60 series duly manufactured using UPVC reinforced profiles of 108mmx45mmx2.5mm for outer frames, and window sash of 39mmx58mmx2.25mm forcapable of mounting single glazing system, structurally reinforced with hot dip galvanized upto 50 microns of minimum thickness of 1.5mm prefabricated and welded through fluxion welding the door sash shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories the clipping locking system made of aluminum 1 No. per set of sashes and the system is to be installed at the site using anchor fasheners,l silcon rubber sealant easy glazing/ deflating at site etc. including cost and conveyance of all materials accessories, labour charges, materials and conduct conforming to ASTMD 638-14 EN-477-95 and other applicable codes and standard.
54Supplying and fitting fixing of Un-plasticized Poly Vinyl Chloride (UPVC) (FENESTA/NICL/VEKA LTD) Casement Ventilator / Top hung duly manufactured using UPVC reinforced profiles of 60mmx55mmx2.5mm for outer frames, 75mmx60mmx2.25mm for casement Window sash profile and 74mmx60mmx2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanized upto 50 microns of minimum thickness of1.5mm prefabricated and welded through fluxion welding the door sash shall be fitted with 12mm thick WPC Board of Greenly make duly fixed with EPDM weathering seal resistant accessories the clipping locking system made of aluminum 1 No. per set of sashes and the system is to be installed at the site using anchor fasheners,l silcon rubber sealant easy glazing/ deflating at site etc. including cost and conveyance of all materials accessories, labour charges, materials and conduct conforming to ASTMD 63-14 EN-477-95 and other applicable codes and standards.
55Supplying fitting and fixing of Granite StoneCladding (sample of Granite stone should be approved by the EIC) for temple external and internal wallover 12mm thick cement plaster(1:1) including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge
56Construction of granular sub-base by providing close graded Granular sub-base Grading-VI materialsas per table 400-I, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MORT&H Specification for Road & Bridge works (5th Revision) as directed by the Engineer in charge
57Providing, laying, spreading and compacting graded stone aggregate to Wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in sub-base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406 of MORT&H specification for Road and Bridge works(5th Revision) as directed by the Engineer in charge
58Rough stone dry packing in aprons and revetments, stone pitching in slopes and boulder apron etc with hard stone of size 30 cm and above and weighing not less than 40Kg as per approved drawing and Section 900, 1000 & 2500 of specifications for road and bridge works of Ministry of Road Transport & Highways (5th Revision) & including cost of all materials, labour, T&P, taxes, royalty etc complete in all respect and as per direction of the Engineer-in-charge.
59Construction of embankment with garden soil obtained from borrow pits with all lifts and leads, transporting to site by mechanical means within a lead of 5 km. spreading, grading to required slope and compacting to meet requirement of table 300-2 & Clause 305 of MORT&H specifications for Road & Bridge works(5th Revision).
60Providing and laying Neelgiri / Mexian grass turf etc.including cost of all materials and labouretc complete as per specification and direction of Engineer in charge
61Providing and fixing of Mangalore pattern tile with cost of materials and labour etc complete as per specification and and direction of Engineer in charge.
62EI work- Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZHPVC insulated copper conductor of ISI markedMake- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI or equievalant reputed makeA catagory ISI marked as approved with 20 mm dia PVC flexible non metallic conduit FRLStype ISI markedMake-AKG/Anchor/Havells or equievalant reputed make A catagory ISI marked as approved 6A modular type ( falme retradant type)switch ISI marked Make-Schneider(Zencelo)/legrand( myrious) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved, and ceiling rose ISI marked Make- Anchor/Havells of modular type G.I box with metallic cover plate (both side) ( falme retradant type) Make-Schneide/legrand/Panasonic or equievalant reputed make & model A catagory ISI marked as approvedof suitable size, modular box with 1.5 sq. Mm FRLSHPVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. CATAGORY AS FOLLOWS ,complete suitable. All the switches & sockets should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. GROUP-A
63GROUP-B
64GROUP-C
65Group control of point in Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZHPVC insulated copper conductor of ISI markedMake-Make- Finolex/Anchor/Polycab/HAVELLSor equievalant reputed make A catagory ISI marked as approved as approved20 mm dia PVC flexible non metallic conduit FRLStype ISI markedMake-AKG/Anchor/Kinjal or equievalant reputed make A catagory ISI marked as approvedwith 6A modular type(( flame retradant type)) switch ISI markedMake-Schneider/legrand/Panasonic or equievalant reputed make & model A catagory ISI marked as approved,and ceiling rose ISI markedMake-Schneider)/legrand /Panasonic (Equievalant model) or equievalant reputed make & model A catagory ISI marked as approved of modular type G.I box withmetallic cover plate (both side) falme retradant type) Make-Schneider/legrand /Panasonicor equievalant reputed make & model A catagory ISI marked as approved, of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. CATAGORY AS FOLLOWS ,complete suitable.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
66Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider/legrand /Panasonic or equievalant reputed make & model A catagory ISI marked as approved, complete suitable for for QUTS.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
67Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type))with suitable size modular box & cover( falme retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider/legrand /Panasonicor equievalant make & model ISI marked as approved , complete suitable .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 5 yearsagainst manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
68Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)( falme retradant type))with suitable size modular box & cover( falme retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision)or equievalant reputed make A catagory ISI marked as approved,(For equipement power)All the switches & sockets should be warrantied for a replacement period of 10 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
69Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6Aswitch & socket(modular type) ( ( falme retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider/legrand /Panasonicr equievalant reputed make & model A catagory ISI marked as approved, (For equipement power)complete suitable forfor OFFICE.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
70Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSH/LSZHinsulated, copper conductor, single core cable (Finolex/Anchor/Polycab/ HAVELLS/RR KEBLE) or equievalant reputed make A catagory ISI marked as approved, inrecessed PVC conduit Heavy duty FRLS of mentioned size (AKG/Anchor/Kinjal or equievalantISI marked as approved) as required as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallicheavy duty flexible conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
712 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty flexible conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5)
724 nos single core 2.5 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor .in 25 mm dia non metallicheavy duty flexible conduit(LDB to LSB/5A SOCKET) (4X2.5+2X2.5)
732 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty flexible conduit .(PDB to PSB/ GAYSER POINT/AC POINT/ROOM LIGHT CONTROL TO CORRIDOORPOINT/DG PANELESSENTIAL LOAD) (2X4+1X1.5)
742 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallicheavy duty flexible conduit .(LFDB TO LBDB) (2X6+1X2.5)
75Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 32 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.. . Make-Legrand/Schneider/Siemens/panasonic or equievalant reputed make & model A catagory ISI marked as approved,All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
76Supplying and fixing following size/ modules, GI box along with modular base & metallic cover plate (both side) plate for modular switches in recess etc as required as per direction of Engg.-in-Charge. MAKE-Legrand/Siemens/Anchor/Panasonic/ Schneider or equievalant reputed make & model A catagory ISI marked as approved .All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. 4 moudle(125mmx75mm)
771 moudle(75mmx75mm)
7812 moudle(200mmx150mm)
79Supplying and fixing of following sizes of medium class PVC FRLS conduitISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .MAKE KINJAL/ AKG/Anchor or equievalant reputed make A catagory ISI marked as approved 20 MM
8025 MM
81Supply and fixingmodular type indicator on the existing switch box/cover . Equievalant higher model of Schneider/Hager/Siemens/Anchor/Panasonicmake or equievalant reputed make & model A catagory ISI marked as approved as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
82Supply and fixingCALL bell (Ding dong type) /Buzzer on the existing switch box/cover. Equievalant higher model ofSchneider/Hager/Siemens/Anchor/Panasonicmake or equievalant reputed make & model A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
83S/F of Bakelite angle holder/batten holder (make-Anchor/Havells/Panasonic or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling roseas per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
84Supplying,fixing of Blanking plate(modular type)( flame retradant type))in existing switch box(anti bactorial & falme retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider/legrand /Panasonic complete suitablestandard hospital.Itshould be warrantied for a period of 5 yearsagainst manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
85Supplying, installation, of exhaust fan of heavy duty 300 mm sweep(Make-Equievalant higher model with 5 star ratedof Havells/almonard/Anchor/Panasonic/Usha/Halonix or equievalant reputed make & model A catagory ISI marked as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 5 years.
86Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan Make-Equievalant higher model with 5 star ratedof Havells/almonard/Anchor/Panasonic/Usha /Halonix or equievalant reputed make & model A catagory ISI marked as approved ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 5 years.. .(With fan Regulator)
87Supplying and fixing of Energy efficient surface mounted square shape 18 W LED luminaireof dimension of 225x 225 x 35 mm consists ofwhite powder coated , die-castAlluminiumhousingwith high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 20 watt and lumen output of 1500 lumens, , CRI not lessthan 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , L70 B50: 30000 hrs (2 yrs warranty)and all other accessories suitable for operationon 220 V to 240 Vsupply as required as per direction of Engg.-in-Charge. ( Make : (Make: wipro LD80-171-60-XX-SM or similar modelofLT/Trilux /Philips/Panasonic/HALONIXor equievalant reputed make & model A catagory ISI marked as approved).The luminaire should be Replacement Warranty will be 5 years
88SITC of IP 20 Non-integral flexible LED strip light,High optically efficient diffuser,, 4000K with 12 w/mtr @ 5Mtrpool with Driver extra as required as per direction of Engg.-in-Charge ( MakeofHavells/ Bajaj/PHILIPS/Wipro or equievalant reputed make & model A catagory ISI marked as approved. )
89Supplying and fixing of small focus light for small monuments In/outdoor type as 6-12W , 5700 Krequired as per direction of Engg.-in-ChargeMake : Panasonicorsimilar modelof Havells/Bajaj/PHILIPS/LT/WIPRO or equievalant reputed make & model A catagory ISI marked as approved.)
90Supplying and fixing of 1KVA solarUPS with 220AH lead acid battery as per direction of Engg.-in-ChargeMake : Luminus/Microtechor equievalant reputed make & model A catagory ISI marked as approved.)
91SITC of energy efficient LED tube light fittings with decorative alluminiumbatten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories withdiffuser having 5 years warrantyi/c connection etc as requiredas per direction of Engg.-in-Charge. ( (Make: wipro LL20-221 --or similar modelofLT/Trilux /Philips/Panasonic/HALONIXor equievalantreputed make & model A catagory ISI marked as approved.). The luminaire should be Replacement Warranty will be 5 years .
92SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. ( Make : WIPRO Model No:LL20-111-XXX-60-NE orsimilar modelof PHILIPS/Panasonic/HALONIXor equievalant reputed make & model A catagory ISI marked as approved. )The luminaire should be Replacement Warranty will be 5 years
93Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
94Supplying and fixing of following mentionedway, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant reputed make & model A catagory ISI marked as approved.as per direction of Engg.-in-Charge. The Distribution boardsshould be Replacement Warranty will be 5 years Supply and fixing of 12 wayDD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (ALL LIGHT WITHCORRIDOOR/COMMON AREA,EM LIGHT,UPS LOAD, EM LOAD LIGHT LOAD,POWER LOAD )
95Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model)or equievalant reputed make & model A catagory ISI marked as approved.the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The MCBshould be Replacement Warranty will be 5 years.MCB should have the fault indication system in different colour for ON, OFF & TRIP condition or Mid trip position for Trip conditions for easier identification of fault.Warranty on MCB is 5years.
96Supplying and fixing 25Amps DP 240 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T/Panasonic /ABBor equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge.TheRCCBshould be Replacement Warranty will be 5 years
97Supplying and fixing 40Amps DP 240 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T/Panasonic /ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge. TheRCCBshould be Replacement Warranty will be 5 years
98S/IT/C of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ terminationofG.I. flat / wire withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing systemshould be Replacement Warranty will be 5 years
99Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge.
100Supplying and making brick massonary pedastal with extra super structure including cement plastering etc as required as per direction of Engg.-in-Charge.
101Supplying of one number PVC insulated armoured and PVC sheathed XLPE propertyAL. conductor power cable of 1.1 KV gradePOLYCAB/HAVELLS/Finolex or equievalant reputed make ISI marked as approved of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials 3.5core x 70 sq mm (MAINOFP PANEL)
102Supplying,laying of 3cx4 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
103Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
104Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.3.5 core x70 sq mm
105Providing,fixing and laying of fallowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.80 mm dia
106Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete withfitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 100 mm dia
107S/I/T&Commissioning of LToutdoor floor mounted cubical typedouble door electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed asG.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessoriesmust be 5 years & compelete test certificate must be submitted along with panel board including component list.In commer- 01 number of125(100-125) Amps 4P MCCB with Rom & sprader link,36 kA & 01 no of 125A 4P changeover switch. . (make-ABB/Siemens/SCHNEIDER/L&T/Legrand, ISI marked)(Icu=50%Ics)with shunt trip.with axulary for BMS Busbar- 04 numbers of150Amps al. busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 63A 4P MCB 8NOS FOR POWER BDB & timer panel (Legrand/Schneider make)Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication (iii) 04 nos of 65kA SP VSD WITH 32A SP MCB
108HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions ofsize 54mm(H) x 200mm(W),of Legrand - Cablofil make or equievalant reputed make & model A catogory, ISI marked as approved.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge. Warrentee period oftraymust be 5 years & compelete test certificate must be submitted .
109Supply installation testing commissioningof Elegant look30 W AIO LED Solar Street lights having extruded alluminium housing, 60 Wp or moreMono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 24 Ah or moreLiFePO4 battery(BIS certified) , BMS, MPPT charge controller having efficiency> 92 % (As per EN 50530 ), PIR sensor to provide 2 days (24 hrs ) back up in dimming mode.The luminaire is having IP 65 protection for critical components, IK 07 and having lumen output of 4500 lumen or more in 3000K as perLM 79 report of third party NABL lab . The luminairelumen efficacy > 150 lm/w or more,Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party NABL lab reports to justify luminaire output , IK 07 and IP 65 protection ( In house NABL lab reports will not be acceptable).The solar light shall be of Philips/Anchor by Panasonic/Wipro only and these solar light should be supplied along with adjustable type mounting bracket which can be fitted directly on the 6mtr long hot dip Galvanizedpoleduly painted to enhance the aesthetic of the pole (as per the direction of EIC)having top dia of 75 mm ODhaving thickness of 3 mm complete with all accessories to embed it into the ground for 1 mtr so that the pole height shall be 5 mtr above ground. . The solar lighting company must be havingtollfree base service network located within 100KM from the project site to provide immediate after sales service within 3 years warranty period . The solar lighting companymust have own NABL accredieted laborotory & lighting design team to provide lighting design .The following reports/ certifications ofsolar light to be submitted for technical acceptance of AIO solar light and must be in the name of Lighting company manufacturer only. 1. EN50530 – MPPT Efficiency , 2.. IEC61547 , 3.IEC61000-3-2 – EMC , 4. IEC 60598 – Part 1 – General requirement ,5. IEC 62109 , 6.LM 79 REPORT (Third party NABL lab only) , 7.IK 07, 8.IP 65 Make of AIO Solar street lights: Philips /Anchor Panasonic/Wipro or equievalant make ISI marked as approved as per direction of Engg. in Charge.
110Supply ,Installation testing commissioning of Asthetically designed 40-45W(post top), High efficient LED comprises with spun aluminium top cover ,dicast aluminium heatsink,frosted polycarbonate diffuser with dicast mounting base arm.CRI>70, IP65, Ambient temp-0 to 45DegC, Driver efficiency>85%, CCT-4000/5700K,THD<10%,Powerfactor>0.95, Surge protection-4 kV internal and 10KV external, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-300V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen = 4600 lumens (115 lm/W). Similar to of PANASONIC Make or equivalent Wipro/Philips/ LT/Trilux make. & model A catogory, ISI marked as approved, with proper model make having warrantied for a period of 5 years .The luminaire to be installed in 6 mtr long GI hot dip galvanized smart pole with anti corroson,,uv rays stabilized,metal post with covered by resinof Fumatech/Valmount/Transrail/RR/UTKASH /Utkal Galvanizer make equievalant make with proper model complete with SA bracket internal JB with 4 way connector and MCBas per the pole drawing and direction of EIC against which inspection mat take place.It should be installed after making proper size RCC foundation by considering RCC foundationby using M20 grade RCC & Fe 415 grade reinforcement and fixing the 4 nos. En 8 grade J type fdn bolts in the foundation. The luminaire needs to be wired with 3 c 1 sq mm wire from JB as per the direction of Engg-in -charge.
111Supplying, Erection, Fixing, connection & testing of45 LED GATE Light ofWIPRO make or equvalant of Philips/LT/PANASONICor equievalant reputed make A catagoryISI marked as approved maintenance free having 2 years warrantyG.I P ipewith braket including MCB box & including with foundation as per the Drawing for inspection as required & as perdirection of Engg.-in-Charge.
112Supplying, Erection, Fixing, connection & testing of 8W, High efficient LED with Aluminium housing with clear toughened glass diffuser.CRI>70, IP65, CCT - 2700K, Ambient temp-0 to 45 DegC, Driver efficiency>85%,THD<25%, Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage driver and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen = 600 lumens (75 lm/W). Similar to Panasonic/Wipro Makeor equivalent Philips/ LT/Trilux make. as per the Drawing for inspection as required & as perdirection of Engg.-in-Charge.
113Supplying ,installation & fixing of asthetically designed IP65 LED bollard comprises of galvanized extruded mild steel pipe housing with opal polycarbonate diffuser and aluminium base, 10W, CRI>70, IP65, CCT - 5700K, Ambient temp-0 to 45DegC, Driver efficiency>80%,THD<25%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage driver and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen = 900 lumens (90 lm/W). Similar to Panasonic Cat No-PBDM03108 or equivalant of Philips/ LT/Trilux make. including with foundation as per the Drawing for inspection as required & as perdirection of Engg.-in-Charge.
114Supplying ,installation & fixing of 6W, High efficient LED outdoor(multi colour,water proof))with extruded Aluminium housing with PC diffuser.CRI>70, IP65, CCT - 6500K, Ambient temp-0 to 45DegC, Driver efficiency>80%,THD<25%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage driver and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen = 565 lumens (51 lm/W). Similar to Panasonic/Wipro Make or equivalent Philips/ LT/Trilux make. including installation under water as per the Drawing for inspection as required & as perdirection of Engg.-in-Charge.
115Supplying ,installation & fixing of 7W, High efficient LED outdoor SPOT LIGHT with extruded Aluminium housing with PC diffuser.CRI>70, IP65, CCT - 6500K, Ambient temp-0 to 45DegC, Driver efficiency>80%,THD<25%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage driver and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen = 565 lumens (10 lm/W). Similar to Panasonic/Wipro Make or equivalent Philips/ LT/Trilux make. including installation under water as per the Drawing for inspection as required & as perdirection of Engg.-in-Charge.
116Supplying ,installation & fixing of 20W, High efficient LED outdoorSPIKE with extruded Aluminium housing with PC diffuser.CRI>70, IP65, CCT - 6500K, Ambient temp-0 to 45DegC, Driver efficiency>80%,THD<25%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage driver and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen 70 lm/W). Similar to panasonac/WiproMake or equivalent Philips/ LT/Trilux make. including installation under water as per the Drawing for inspection as required & as perdirection of Engg.-in-Charge.
117SITC of IP 65 Non-integral flexible LED strip light in 5 mtr length with 12W/Mtr power consuption available with wide beam angle 120 degree is equipped with separate energy efficient isolated electronic driver for safe operation., 3000K with 12 w/mtr @ 5Mtrpool with Driver extra,all requiredaccessories with laying base as required as per direction of Engg.-in-Charge ( Make :(Make: PANASONICor similar modelofLT/Trilux /Philips/WIPRO or equievalant or equievalant reputed make & model A catagory ISI marked as approved. )The luminaire should be Replacement Warranty will be 5 years
118Supply of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ terminationofG.I. flat / wire withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing systemshould be Replacement Warranty will be 5 years
119Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required as per direction of Engg.-in-Charge.
120Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
121Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPEAL. conductor power cable of 1.1 KV gradePOLYCAB/FINOLEX/HAVELLS or equievalant reputed ISI MARKED MAKE of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials 4core x 10 sq mm (OFP TO IND. TIMER PANEL)
1224 core x 4 sq mm (for small power/LIGHT TO POLE)
123Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
124Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
125Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
126Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete withfitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials 50 mm dia
127S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type timer panel with 32A 4P MCB ,40A TP CONTACTOR ,TIMER with 6 nos 10A 4P MCB C as per direction of Engg.-in-Charge. .(Equievalant modeleach item of Legrand/Schneider/L&T/ABB or equievalant make & model)Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for 2 years after acceptance of materials.
128Supplying, installation, testing & commissioning ofoutdoor digital signage display of park in & out with all required asper direction of Engg. In charge.
129S/I/T&Commissioning of LT OUT DOOR type mini mast with 8 mtrs with timer panel ,octagonal pole along with roundbraket ,4 nos 150w LED flood light having aluminium dicast housing powder coated in umbra grey , toughened glass diffuser, system ifficacy-110 LPW, col Temp- 5700, CRI-70, surge protection-4KV internal & 10 KV external to be placed inside the luminaire, Integral & constant current driver, IP66, IK07 protectedwith foundation .Make-Panasonic/Bajaj/wipro or equievalant.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for 5 years after acceptance of materials.
130P.H. Works:-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778 of SDR-11, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia
13125mm dia
13220mm dia
133Supplying all materials,labour,T&P & fitting and fixing of following different water supply fittings as per ASTMD-2846 with supply of all necessary jointing materials etc all complete as per direction of Engineer-in-charge. 32mm dia CPVC ball valve
13425mm dia CPVC ball valve
135Supplying all labour , T&P and materials & making grooves in brick/stonewall vertically and horizontally to the required depth & width for fixing pipes & fitting in grooves , testing the pipe line against the leakage & filling the grooves with CM ( 1:4) to bring the surface to the original level including the cost of the machine , conveyance etc all complete as per the direction of Engineer-in-charge.
136Supplying all materials labour,T&P and cutting holes through existing brickwork including supply of all materials & making good the damages for taking PVC pipes and fittings etc all complete as per PH specification and direction of the EIC 20mm to 50mm PVC to pass in 125mm to 250mm thick Brick/stone wall
137Kitchen Sink (Nirali Elegance Large glossy ( 650x450x250) mm /Equivalent with drain board
138Supplying all materials, labour, taxes, T & Pforfitting & fixingof different water supply CP , Brass or GM concealed fitting andfixtures of ISI approved make of following sizes and specification with leak proof threaded joints tightened with spun yam and white zinc or any other method as required and directed including testing and rectification of defects after testing,includingcost of all labours, materials, conveyance, loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.. Angular Stop Cock With Wall Flange- Jaquar FLR- 5053N / Equivalent
139Soap Dish Holder- JAQUAR ACN-1131N/ Equivalent
140Soap Dispenser with Glass bottle (JaquarAKP-35735P/Equivalent)
141CP Flanges
142CP Grating with floor trap
14315mm dia CP extension piece- Astral T143-010M/ Equivalent
144Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm dia UPVCpipe(Type-A)
145Supply all materials ,labour,T&P,fitting and fixing UPVC SWR Type B pipes & fittings of approved make confirming to IS-13592 including jointing of approved solvent cement non-heat application method including testing of as per standard specification ,both below & above ground level/floor & on walls including supply of bobbins,nains,screws,wooden cleats ,pipe clamps as per requirement including earthwork excavation & fitting ,including cutting walls & floor & making good the damages with cement concrete (1:2:4) with hard granite chips ,including scaffolding wherever necessary all complete with requisite testing as per direction of the EIC (Make: ASTRAL/SUPREME/EQUIVALENT)110mm dia UPVC SWR pipe(Type-B)
146110mm U-PVC Door bend
147110mm U-PVC door Tee
148110mm U-PVC plain Bend
149110mm U-PVC door Cross Tee
150110mm U-PVC Offset.
151110mm U-PVC "P" trap
152110mm U-PVC vent cowl with ss jali
153110mm pipe clip
154Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, K.B brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge Gully trap chamber of size 250mmx250mm with R.C.C cover slab
155Supplying all materials, labour, T&P and constructing inspection chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeInspection chamber Inside size 760mmx760mmx460mm
156Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4984/2016 of the following outside dia for Pressure rating PN-6 including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 160mm dia u-pvc pipe alround concrete
157Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778 of SDR-11, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia
15832 mm dia
15925mm dia
16020mm dia
161Supplying all materials,labour,T&P & fitting and fixing of following different water supply fittings as per ASTMD-2846 with supply of all necessary jointing materials etc all complete as per direction of Engineer-in-charge. 32mm dia CPVC ball valve
16225mm dia CPVC ball valve
163Supplying all labour , T&P and materials & making grooves in brick/stonewall vertically and horizontally to the required depth & width for fixing pipes & fitting in grooves , testing the pipe line against the leakage & filling the grooves with CM ( 1:4) to bring the surface to the original level including the cost of the machine , conveyance etc all complete as per the direction of Engineer-in-charge. 15mm to 32mm dia pipe
164Supplying all materials labour,T&P and cutting holes through existing brickwork including supply of all materials & making good the damages for taking PVC pipes and fittings etc all complete as per PH specification and direction of the EIC 20mm to 50mm PVC to pass in 125mm to 250mm thick Brick/stone wall
165Kitchen Sink (Nirali Elegance Large glossy ( 600x450x250) mm /Equivalent with drain board
166Supplying all materials, labour, taxes, T & Pforfitting & fixingof different water supply CP , Brass or GM concealed fitting andfixtures of ISI approved make of following sizes and specification with leak proof threaded joints tightened with spun yam and white zinc or any other method as required and directed including testing and rectification of defects after testing,includingcost of all labours, materials, conveyance, loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.. Angular Stop Cock With Wall Flange- Jaquar FLR- 5053N / Equivalent
167Soap Dish Holder- JAQUAR ACN-1131N/ Equivalent
168Soap Dispenser with Glass bottle (JaquarAKP-35735P/Equivalent)
169CP Flanges
170CP Grating
17115mm dia CP extension piece
172Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm dia UPVCpipe(Type-A)
173Supply all materials ,labour,T&P,fitting and fixing UPVC SWR Type B pipes & fittings of approved make confirming to IS-13592 including jointing of approved solvent cement non-heat application method including testing of as per standard specification ,both below & above ground level/floor & on walls including supply of bobbins,nains,screws,wooden cleats ,pipe clamps as per requirement including earthwork excavation & fitting ,including cutting walls & floor & making good the damages with cement concrete (1:2:4) with hard granite chips ,including scaffolding wherever necessary all complete with requisite testing as per direction of the EIC (Make: ASTRAL/SUPREME/EQUIVALENT) 110mm dia UPVC SWR pipe(Type-B)
174110mm U-PVC Door bend
175110mm U-PVC door Tee
176110mm U-PVC plain Bend
177110mm U-PVC door Cross Tee
178110mm U-PVC Offset.
179110mm U-PVC "P" trap
180110mm U-PVC vent cowl
181110mm pipe clip
182Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, K.B brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge Gully trap chamber of size 250mmx250mm with R.C.C cover slab
183Supplying all materials, labour, T&P and constructing soakway pit of the following size with precast RCC rings joined loose, gravel backing in the rear of well steining, precast RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeRCC rings soakway pit 1.22m dia x 2.10m deep
184Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4984/2016 of the following outside dia for Pressure rating PN-6 including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 160mm dia u-pvc pipe alround concrete
185Supplying all materials, labour, T&P and fixing PVCwater storage tanks of 2000 ltr capacity (shade white) confirming to IS:12701-1996 including cutting holes through the tank and fixing pvc pipe and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including conveyance of all materials to worksite etc all complete as per specification and direction of Engineer-in-charge. 2000 ltr capacity water storage tanks-1 Nos with stagging etc all complete as per specification and direction of Engineer-in-charge.
186WATER SUPPLY & SANITATION WORKS Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778 of SDR-11, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia
18732 mm dia
18825mm dia
18920mm dia
190Supplying all materials,labour,T&P & fitting and fixing of following different water supply fittings as per ASTMD-2846 with supply of all necessary jointing materials etc all complete as per direction of Engineer-in-charge. 40mm dia CPVC ball valve
19132mm dia CPVC ball valve
19225mm dia CPVC ball valve
193Supplying all labour , T&P and materials & making grooves in brick/stonewall vertically and horizontally to the required depth & width for fixing pipes & fitting in grooves , testing the pipe line against the leakage & filling the grooves with CM ( 1:4) to bring the surface to the original level including the cost of the machine , conveyance etc all complete as per the direction of Engineer-in-charge. 15mm to 32mm dia pipe
194Supplying all materials labour,T&P and cutting holes through existing brickwork including supply of all materials & making good the damages for taking PVC pipes and fittings etc all complete as per PH specification and direction of the EIC 20mm to 50mm PVC to pass in 125mm to 250mm thick Brick/stone wall
195Supplying all materials , labour T&P and cutting hole in RCC floors,roofs,etcfor passing PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the EIC 20mm to 50mm PVC to pass in 125mm to 250mm thk RCC
196Providing & Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification. MAKE :- HINDWARE/ JAQUAR/ PARRYWARE/ Equivalent. Water Closet Complete set - HINDWARE -20100+21054/ Equivalent
197Orissa pan complete set - HINDWARE -20076/ Equivalent
198Providing and fixing of following size Wash Basin with 175mm Long Wall Connection Pipe includingpainting of fittings and brackets, cutting and making good the walls wherever requiredwith provision for pillar cock but excluding the cost of pillar cock, including all cost of labour, material, conveyance, loading, unloading, T&P etc. all complete as per the direction of Engineer-in-charge. MAKE :- HINDWARE/ JAQUAR/ PARRYWARE/ Equivalent. Under counter wash basin Complete set (HINDWARE LARACODE NO.10095 Starwhite/ Equivalent), Bottle Trap - ( Jaquar cat no-ALD-769L300x190/Equivalent) , Waste Coupling -(Jaquar cat no-ALD-705/Equivalent)
199Wash hand basin with porcelain pedestal(Hindware)-91049
200Supplying all materials, labour, taxes, T & Pforfitting & fixingof different water supply CP , Brass or GM concealed fitting andfixtures of ISI approved make of following sizes and specification with leak proof threaded joints tightened with spun yam and white zinc or any other method as required and directed including testing and rectification of defects after testing,includingcost of all labours, materials, conveyance, loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.. 2 Way Bib Cock With Wall Flange(Plaza/Aquatic/Amber)
201Pillar Cock with lift type operating knob & Base Flange- (Plaza/Aquatic/Amber)
202Angular Stop Cock With Wall Flange- (Plaza/Aquatic/Amber)
203Towel Rail 600mm Long,-
204Towel Ring-
205Soap Dish Holder-
206Health Faucet(Plaza/Aquatic/Amber)
207Glass Shelf
208CP Flanges
209CP Grating
21015mm dia CP extension piece
211Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm dia UPVCpipe(Type-A)
212Supply all materials ,labour,T&P,fitting and fixing UPVC SWR Type B pipes & fittings of approved make confirming to IS-13592 including jointing of approved solvent cement non-heat application method including testing of as per standard specification ,both below & above ground level/floor & on walls including supply of bobbins,nains,screws,wooden cleats ,pipe clamps as per requirement including earthwork excavation & fitting ,including cutting walls & floor & making good the damages with cement concrete (1:2:4) with hard granite chips ,including scaffolding wherever necessary all complete with requisite testing as per direction of the EIC (Make: ASTRAL/SUPREME/EQUIVALENT) 110mm dia UPVC SWR pipe(Type-B)
213110mm U-PVC Door bend
214110mm U-PVC door Tee
215110mm U-PVC plain Bend
216110mm U-PVC door Cross Tee
217110mm U-PVC Offset.
218110mm U-PVC "P" trap
219110mm U-PVC vent cowl
220110mm pipe clip
221Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, K.B brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge Gully trap chamber of size 250mmx250mm with R.C.C cover slab
222Supplying all materials, labour, T&P and constructing inspection chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Inspection chamber Inside size 760mmx760mmx460mm
223Supplying all materials, labour, T&P and fixing PVCwater storage tanks of 2000 ltr capacity (shade white) confirming to IS:12701-1996 including cutting holes through the tank and fixing pvc pipe and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including conveyance of all materials to worksite etc all complete as per specification and direction of Engineer-in-charge. 2000 ltr capacity water storage tanks-1 Nos with stagging all complete as per specification and direction of Engineer-in-charge.
224Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Cooler-cum-Purifier of size (700x430x460mm ht) with water cooling capacity of 40 PPH with contineously flow with one faucet having option for cold water and normal water etc.with internal water supply connection complete as per direction of the Engineer-in-charge.
225WATER SUPPLY & SANITATION WORKS Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778 of SDR-11, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia
22625mm dia
227Supplying all materials,labour,T&P & fitting and fixing of following different water supply fittings as per ASTMD-2846 with supply of all necessary jointing materials etc all complete as per direction of Engineer-in-charge. 32mm dia CPVC ball valve
22825mm dia CPVC ball valve
229Supplying all labour , T&P and materials & making grooves in brick/stonewall vertically and horizontally to the required depth & width for fixing pipes & fitting in grooves , testing the pipe line against the leakage & filling the grooves with CM ( 1:4) to bring the surface to the original level including the cost of the machine , conveyance etc all complete as per the direction of Engineer-in-charge. 15mm to 32mm dia pipe
230Supplying all materials labour,T&P and cutting holes through existing brickwork including supply of all materials & making good the damages for taking PVC pipes and fittings etc all complete as per PH specification and direction of the EIC 20mm to 50mm PVC to pass in 125mm to 250mm thick Brick/stone wall
231Supplying all materials, labour, taxes, T & Pforfitting & fixingof different water supply CP , Brass or GM concealed fitting andfixtures of ISI approved make of following sizes and specification with leak proof threaded joints tightened with spun yam and white zinc or any other method as required and directed including testing and rectification of defects after testing,includingcost of all labours, materials, conveyance, loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.. Angular Stop Cock With Wall Flange- Jaquar FLR- 5053N / Equivalent
232CP Flanges
233CP Grating
23415mm dia CP extension piece
235Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm dia UPVCpipe(Type-A)
236Supply all materials ,labour,T&P,fitting and fixing UPVC SWR Type B pipes & fittings of approved make confirming to IS-13592 including jointing of approved solvent cement non-heat application method including testing of as per standard specification ,both below & above ground level/floor & on walls including supply of bobbins,nains,screws,wooden cleats ,pipe clamps as per requirement including earthwork excavation & fitting ,including cutting walls & floor & making good the damages with cement concrete (1:2:4) with hard granite chips ,including scaffolding wherever necessary all complete with requisite testing as per direction of the EIC (Make: ASTRAL/SUPREME/EQUIVALENT) 110mm dia UPVC SWR pipe(Type-B)
237110mm U-PVC Door bend
238110mm U-PVC door Tee
239110mm U-PVC plain Bend
240110mm U-PVC door Cross Tee
241110mm U-PVC Offset.
242110mm U-PVC "P" trap
243110mm U-PVC vent cowl with ss jali
244Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, K.B brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge Gully trap chamber of size 250mmx250mm with R.C.C cover slab
245Supplying all materials, labour, T&P and constructing inspection chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeInspection chamber Inside size 760mmx760mmx460mm
246Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778 of SDR-11, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia
24720mm dia with stand post
248Construction 1 nos 100 users RCC Septic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of theEngineer-in-Charge.
249- do - with addl. Depth of 1.5 m
250Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge In ground floor
251Supplying all materials, labour, T&P andproviding cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. In ground floor
252Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge In ground floor
253Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
254Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge For Roof slab
255For RCC wall
256Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
257Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
258Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification anddirection of the Engineer in charge
259Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
260Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
261Earth work excavation in ordinarysoil within 50 m, initial lead and1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm laying in layers not exceeding 0.3m in depth and earth trasported by transport vehicles as per the direction of the Engineer-in-charge.
262Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate 20 mm nominal size ) of approved quality from quarrymixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period .including all cost of labour ,material,conveyance,royalties and taxes ,sundries ,T & P etc. & including the cost of centering and shuttering all complete as per the directions of Engineer-in-charge.
263RCC work M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 N. / Square mm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using 12 mm. to 20 mm. size black hard crusher broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned (20 mm. size chips not to exceed 25 % ) to be mixed in concrete mixture with approved grade cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days and finishing the exposed surface smooth providing grooves or beads wherever necessary including centering & shuttering cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P, required for the work etc. complete in all respect as per direction of the Engineer in charge. Raft
264R.C.C Wall
265Slab
266Providing, fixing in position TMT Fe-500/ 500D (IS-1786-1985) reinforcement bars for RCC work of required diameter of approved SAIL/ TATA / RINL (VIZAG)/ JINDAL make including straightening, cutting, bending, binding, welding and joining (if necessary) and tying the grills and placing in position as required for R.C.C. work and providinghoisting, lowering and laying including cost, conveyance and taxes oftor steel and binding wires of 18 gauge and labour required for the work for bending, binding and tying the grills in all heights as per the specification & direction ofEngineer -in-charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.) Foundation and plinth
267Providing 6mm thick cement plaster with cement mortar of (1:4) to ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves and beads to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing ,sundries and T&P etc all complete as per direction of the Engineer -in-charge Ground Floor
268Providing cement punning to walls including roughening, scraping and cleaning and finishing the surface smooth only to proper plumbs and level, to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing ,sundries and T&P etc all complete as per direction of the Engineer -in-charge
Disclaimer :