Council Of Scientific And Industrial Research-CSIR has published Tender For Minor Repair And Renovation Work Of Guesthouse Attendant Room For Making Transit Accommodation And Other Allied Work At Guesthouse Csir Csmcri Bhavnagar.. Submission Date for this Tender is 14-12-2023. Building Work Tenders in bhavnagar Gujarat. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 07-Dec-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 14-12-2023 |
Sl. No. | Item Description |
1 | PART A CIVIL WORK Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
2 | For thickness of tiles 10 mm to 25 mm |
3 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
4 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
5 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
6 | In cement mortar |
7 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : |
8 | Of area 3 sq. metres and below |
9 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
10 | DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. |
11 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
12 | Disposalofbuildingrubbish /malba /similarunserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond SO m initial lead, for all leads including all lifts involved. |
13 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
14 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
15 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
16 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
17 | Steel work in built up tubular (round, square or rectangular hollow tubesetc.)trussesetc.,includingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer, including welding andbolted withspecial shaped washers etc. complete. |
18 | Hot finished welded type tubes |
19 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
20 | Two or more coats on new work |
21 | (a) Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium (c) composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
22 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
23 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
24 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm) |
25 | Earthworkinexcavationbymechanicalmeans(Hydraulicexcavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. |
26 | All kinds of soil |
27 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
28 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
29 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanitycounters,windowsills,faciasandsimilarlocationsof required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
30 | Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble |
31 | Area of slab upto 0.50 sqm |
32 | Providing and fixing 600x450 mm beveled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washerscomplete. |
33 | Providing and fixing toilet paper holder: |
34 | C.P. brass |
35 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : |
36 | cement mortar 1:4 (1 cement : 4 coarse sand) |
37 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
38 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
39 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. |
40 | Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement: 3coarsesand: 6gradedstoneaggregate 20mm nominal size) including disposal of malba. |
41 | Taking out existing kerb stones of all types from footpath/ centralverge, including removal of mortar etc., disposal of unserviceablematerial to the dumping ground, for which payment shall be madeseparately and stacking of serviceable material within 50 metre leadas per direction of Engineer-in-Charge. |
42 | Laying at or near ground level old kerb stones of all types in positionto the required line, level and curvature, jointed with cement mortar1:3 (1 cement : 3 coarse sand), including making joints with or withoutgrooves (thickness of joints, except at sharp curve, shall not bemore than 5 mm), including making drainage opening whereverrequired etc. complete as per direction of Engineer-in-charge. (Lengthof finished kerb edging shall be measured for payment). (Old kerbstones shall be supplied by the department free of cost) |
43 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
44 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
45 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
46 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
47 | Two coats |
48 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. |
49 | Providing and laying matt finished vitrified tile of size 300x300x9.8mmhaving with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoorfloors such as footpath, court yard, multi modals location etc., laidon 20mm thick base of cement mortar 1:4 (1 cement : 4 coarsesand) in all shapes & patterns including grouting the joints with whitecement mixed with matching pigments etc. complete as per directionof Engineer-in-Charge. |
50 | Providing and laying tactile tile (for vision impaired persons as perstandards) of size 300x300x9.8mm having with water absorption lessthan 0.5% and conforming to IS:15622 of approved make in all coloursand shades in for outdoor floors such as footpath, court yard, multimodals location etc., laid on 20mm thick base of cement mortar 1:4(1 cement : 4 coarse sand) in all shapes & patterns including groutingthe joints with white cement mixed with matching pigments etc.complete as per direction of Engineer-in-Charge. |
51 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions withwire of dia 0.63mm,for doors,windows andclerestory windows with hinges and necessary screws : |
52 | 35 mm thick shutters |
53 | With ISI marked stainless steel butt hinges of required size |
54 | Kiln seasoned and chemically treated hollock wood |
55 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. |
56 | Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture"s specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: |
57 | 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. |
58 | Providing and fixing white vitreous china wall mounting water closet (CERA Cat. No. S1047101) with built in Jet of approved size & shape including seat cover, fittings, nuts, bolts and gasket etc all complete as directed by Engineer In-charge. |
59 | Refixing of available existing sanitary fittings including all consumables and labour etc complete as directed by Engineer In-Charge |
60 | Concealed sanitary fittings (like concealed cock/valve/diverter, etc similar items with concealed body and exposed parts) |
61 | Exposed sanitary fittings (like taps, bib cock, pilar taps, shower rose, health fucets, push cocks, etc similar items) |
62 | Providing and fixing C.P. brass Metropole Flush Valve (concealed body) of standard design and of approved make conforming to IS:8931. |
63 | Dual Flow 32 mm size with Exposed Shut Off Provision & 100mm Square Plate (3.0/6.0 Lts. Per Flushing). |
64 | Providing and fixing Hand Shower (Health Faucet) with 8mm Dia, 1 Meter Long Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer) inclusive of all accessories, overheards etc. all complete as directed by Engineer In-Charge (Jaquar Health faucet - ALD 577). |
65 | Providing and fixing 2 Way Bib Cock with Wall Flange (Jaquar ORP-10041PM) as directed by Engineer In-Charge. |
66 | Providing and fixing Angular Stop Cock with Wall Flange (Jaquar ORP-10053PM) as directed by Engineering In-Charge. |
67 | Providing and fixing white vitreous china wash basin of approved shape and manufacturer including making all connections as directed by Engineer In-Charge: Wash basin 450 x 320 x 130 mm with half pedestal height 390 mm (Cera make basin of Cat No. : S2040158, pedestal of Cat. No. S2090130). |
68 | Providing and fixing concealed stop cock consiting of (i) Regular Body of Concealed Stop Cock Suitable for 20 mm Pipe Line with Protection Cap: Jaquar ALD-089 (ii) Exposed Part Kit of Concealed Stop Cock & Flush Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange with Seal: Jaquar-ORP-10083KPM |
69 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings withonestep CPVCsolvent cementandthe cost of cutting chasesandmaking good thesame including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
70 | 20 mm nominal dia Pipes |
71 | 25 mm nominal dia Pipes |
72 | 32 mm nominal dia Pipes |
73 | Providing andfixingsquare-mouthuPVC SWR grade Gully trap confirming to IS: 13592 and IS 14735 complete with moulded grating, brick masonry chamber with water tight C.I. cover withframe of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: |
74 | 100x100 mm size P type |
75 | With Sewer bricks conforming to IS :4885 |
76 | Providing and fixing PVC SWR grade TYPE B drainage pipes confirming to IS:13592 including fitting with required adhesive/rubber lubricant as per manufacturer"s specification etc all complete for soil, waste and vent pipes as directed by Engineer In-Charge: |
77 | 75 mm dia |
78 | 2 FT S/S length Socket |
79 | 3 FT S/S length Socket |
80 | 4 FT S/S length Socket |
81 | 6 FT S/S length Socket |
82 | 110 mm dia |
83 | 2 FT S/S length Socket |
84 | 3 FT S/S length Socket |
85 | 4 FT S/S length Socket |
86 | 6 FT S/S length Socket |
87 | Providing and fixing PVC SWR grade drainage fittings confirming to IS:14735 including fitting with required adhesive/rubber lubricant as per manufacturer"s specification etc all complete for soil, waste and vent pipes as directed by Engineer In-Charge: |
88 | WC Connector (Straight) |
89 | 110 mm dia |
90 | Nahani Trap without Jali |
91 | 110 x 110 mm dia |
92 | Multi Floor trap without jali |
93 | 110 mm dia |
94 | Single "Y" with door |
95 | 110 mm dia |
96 | 75 mm dia |
97 | Single Tee with door |
98 | 75 mm dia |
99 | 110 mm dia |
100 | Repair Coupler |
101 | 75 mm dia |
102 | 110 mm dia |
103 | Coupler |
104 | 75 mm dia |
105 | 110 mm dia |
106 | Bend 87.5 ? |
107 | 75 mm dia |
108 | 110 mm dia |
109 | Bend 87.5with door? |
110 | 75 mm dia |
111 | 110 mm dia |
112 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
113 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
114 | 30 cm length |
115 | 20 mm nominal bore |
116 | 45 cm length |
117 | 20 mm nominal bore |
118 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. |
119 | Flexible pipe |
120 | 32 mm dia |
121 | Providing and fixing Stainless Steel towel rail complete with brackets fixed with CP brass screws with concealed fittings arrangement of approved quality as directed by Engineer In-charge. |
122 | 600 mm long |
123 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws andPVC sleeves etc., wherever necessary complete : |
124 | 25 mm dia |
125 | Providing and fixing Corner glass self (with SS road railing) with bracket fixed with CP brass screws with concealed fittings arrangement of approved quality as directed by Engineer In-Charge |
126 | Providing and fixing Stainless Steel Recessed type Soap Dish (of approved make & model listed saperately) recessed in wall including cutting and making good the walls with rich mixed cement mortar (1:2) with fitting, etc all completed as directed by Engineer In-Charge |
127 | Providing and fixing PTMT grating of approved quality and colour. |
128 | Rectangular type with openable circular lid |
129 | 150 mm nominal size square 100 mm diameter of the inner hinged round grating |
130 | Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws with appropriate SS round rivet type top cap (to be fixed with necessary arrangement, adhesive etc.) including drilling holes in masonry work /CC/ R.C.C. backing and making good etc. complete for fixing chaukhat/door-window frame, jams or at similar location securing stone wall lining. |
131 | 130 mm long |
132 | PART B ELECTRICAL WORK WIRING IN STEEL & PVC CONDUIT |
133 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface /recessedmediumclassPVCconduit,withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
134 | Group A |
135 | Wiringfortwincontrollightpointwith 1.5sq.mmFRLSPVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
136 | Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. |
137 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
138 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
139 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
140 | 20 mm |
141 | 25 mm |
142 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required. |
143 | 5/6 A switch |
144 | 2 way 5/6 A switch |
145 | 15/16 A switch |
146 | 3 pin 5/6 A socket outlet |
147 | 6 pin 15/16 A socket outlet |
148 | Telephone socket outlet |
149 | TV antenna socket outlet |
150 | Supplyingand fixingtwo module steppedtypeelectronicfan regulatorontheexistingmodularplateswitch boxincluding connections but excluding modular plate etc. as required. |
151 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
152 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required. |
153 | 1 or 2 Module (75mmX75mm) |
154 | 3 Module (100mmX75mm) |
155 | 4 Module (125mmX75mm) |
156 | 6 Module (200mmX75mm) |
157 | SupplyingandfixingfollowingModularbase&coverplateon existing modular metal boxes etc. as required. |
158 | 3 Module |
159 | 12 Module |
160 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connectionsetc. as required. |
161 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
162 | Installation of exhaust fan in the existing opening, including making goodthedamage,connection,testing,commissioningetc.as required. |
163 | Upto 450 mm sweep |
164 | Extrafor fixingthelouvers/shutterscompletewithframefora exhaust fan of all sizes. |
165 | MCCB, MCB & DB"S |
166 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) |
167 | 12 way , Double door |
168 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. |
169 | Single pole |
170 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,residual current circuit breaker (RCCB),having a sensitivity current 30mA inthe existingMCBDBcomplete with connections, testing and commissioning etc. as required. |
171 | 25A |
172 | Supplying and fixing DP sheet steel enclosure on surface/ recess alongwith 25/32A240V"C"curveDPMCBcompletewith connections, testing and commissioning etc. as required. |
173 | EARTHING |
174 | Providingandfixing4.00mmdiacopper wireonsurfaceorin recess for loop earthing as required. |
175 | MV CABLE LAYING |
176 | Laying of one number PVCinsulated andPVC sheathed / XLPE powercableof1.1KVgradeof followingsizedirectinground includingexcavation,sandcushioning,protectivecoveringand refilling the trench etc as required. |
177 | Upto 35 sq. mm |
178 | Non-Schedule/MR |
179 | Supplying, Installation, testing, commissioning of 250 mm sweep with copper winding exhaust fan for bathroom230 Volts,50Hz, single phaseA.C.supplyandmountingframe on teak wooden frame,complete including making the hole in wall and refinished itwith testing,commissioning etc. as required. |
180 | Supplying, installation, testing and commissioning LED panel light 20 W high efficiency, Fixture and Finishing done with stove enamel white body,supplyingwith high quality polycarbonate body with inbuilt electronic driver i/c connection with suitable size PVC insulated copper conductor cable completeetc as required. |
181 | Supplying, installation, testing and commissioning LED surface mounted light 18 W high efficiency, Fixturewhite body,supplyingwith high quality polycarbonate body with inbuilt electronic driver i/c connection with suitable size PVC insulated copper conductor cable complete etc as required. |
182 | Supplying, installation, testing and commissioning of Geyser 3 liter etc as required. |
183 | Supplying Installation Testing Commissioning of 300 mm sweep metal body exhaust fan, HEAVYduty,,230 Volts,50Hz, single phaseA.C.supplyandmountingframe on teak wooden frame,complete including making the hole in wall and refinished itwith testing,commissioning etc. as required. |
184 | Supplying, installation, testing and commissioning 2 feetLED tube light with suitable wattage, high efficiency, Fixture and Finishing done with stove enamel white body,supplyingwith high quality polycarbonate body with inbuilt electronic driver i/c connection with suitable size PVC insulated copper conductor cable completeetc as required. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy