| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level)all as directed by Engineer-In-Charge. |
| 2 | Demolition of cement concrete of any description and in any positionall as directed by Engineer-In-Charge. |
| 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed by Engineer-In-Charge. |
| 4 | Dismantling of plain or corrugated steel sheeting, any gauge or any thickness in roof coveringall as directed by Engineer-In-Charge. |
| 5 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as directed by Engr- In- Charge. |
| 6 | Demolition of precast cement concrete block walling built in cement mortar and precast articles all as directed by Engineer-In-Charge. |
| 7 | Dismantling of wall/ceiling boards (fibre, pulp,insulation etc) or insulation boards/ slabs/blanket any thickness including cover filletsall as specified. |
| 8 | Demolition of brick work/ PCC block masonry or stone/boulder masnory, built in cement mortat or cement lime mortarincluding all quions, arches, pillars etc but excluding ashlar facing dressed stone work and prec ast concrete articles complete all as specified and directed |
| 9 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out soft or loose soil complete all as specified. |
| 10 | Excavation in treches, n exc 1.5 m wide and n exc 1.5m depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out ,for foundation ,etc or for shafts wells, cesspits, m anholes, pier holdes, pipe lines etc in hard/dense soil , complete all as specified and directed |
| 11 | Returning filling in , including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft/loost soil complete all as specified. |
| 12 | Removing excavated surplus material to a distance not exceeidng 50 mtr and depositing where directed a level not exceeding 1.5m above the starting point complete all as specified. |
| 13 | Material and labour for PCC 1:4:8 type D2, 40 mm graded crushed stone aggregates as in foundations, filling and mass concrete complete all as specified. |
| 14 | Material and labour for 100 mm thick PCC 1:2:4, type B2 with using 40 mm gradedstone aggregate as in sub base finished the surface even and rough complete all as specified. |
| 15 | Material and labour for 25 mm thick PCC 1:2:4, type B0 with using 12.50 mm gradedstone aggregate as in flooring finished fair and even complete all as specified and directed by Engr-in-charge. |
| 16 | Material and labour for pavement floor vitrified tiles of size 300 mm x 300 mm x 10mm thick pointed with grey cement and pigment to match the colour of tiles in floor including 20 mm thick screed bed in cement mortar 1:4 complete all as specified.Make: SOMANY/NITCO/KAJARIA/VARMORA |
| 17 | Material and labour for chequered cement concrete tiles 30cm x 30cm x 20mm thick, set jointed and pointed in neat cement slurry in floors, and cut and polished with grey cement and pigment etc., including 20 mm thick screed bed in cement mortar 1:4 complete all as specified.Make: Anjali Tiles/ Ultra Tiles Pvt Ltd/ Terra Firma/ Bansal/ Mehtab Tiles/ Nitco |
| 18 | Material and labour for PCC 1:2:4 type B0 using 12.50 mm graded crushed stone aggregates as in benching complete all as specified. |
| 19 | Material and labour for preparation of old plastered or unplastered wall surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etcand applying one coat of exterior emulsion paint (anti fungal) with roller finish complete all as per manufacturer instruction |
| 20 | Material and labour for preparation of new and previously untreated steel or ironsurfaces of any description, not otherwise described exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over one coat ofred oxideprimer all as specified. |
| 21 | Material and labour for precast cement concrete block 1:3:6 type C1 using 20 mm graded crushed stone aggregates masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6, complete all as specified.Note: Formwork shall be paid including this item |
| 22 | Supply and fix rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410-W (Gde E- 250) quality A complete all as specified. |
| 23 | Supply and fix 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified. |
| 24 | Material and labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. |
| 25 | Material and labour for 15 mm thick renderingin cement mortar 1:6 on brick wall or cement surfaces, finished the surfaces even and smooth without using extra cement complete all as specified. |
| 26 | Material and labour for newly or untreated plastered wall surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additive @ 1.43 litre/ 10 Sqm over and including a coat of exterior primer applied @ 0.902 litre/ 10 Sqm with using roller complete all as per manufacturer instruction. |
| 27 | Material and labour for providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified. |
| 28 | Material and labour for 25 mm thick black granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and demolished the old slab. |
| 29 | Material and labour for old painted steel surfaces of any description over 10 cm width or girth and applying one finishing coat of synthetic enamel paint complete all as specified. |
| 30 | Material and labour for 10 mm thick joint free premium quality dark shed vitrifiedceramic tiles of size 600 mm x 600 mm as in floors set and jointed and pointed in white or colour cement to match existing surfaces laid over 20 mm thick screed bed in cement mortar 1:4 complete all as specified.Make: Somani Ceramic Ltd/ Kajaria Ceramic Ltd/ Varmora Granito Pvt Ltd. |
| 31 | Material and labour for complete removal of old plastered or unplastered wall surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etcand applying two coats of oil bound distemper over a coat of interior primer with roller finish complete all as per manufacturer instruction |
| 32 | Supply and fix anodised aluminium door shutters, aluminium section weighing not less than 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. |
| 33 | Supply and fix powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.Note: The weight shall be measured through Board of Ofiicer which will be conveyed by GE. |
| 34 | Supply and fix mortice lock, vertical type (2 Lever), size 100 mm completre all as specified. |
| 35 | Supply and fix as in repairsaluminium (die cast body) Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 851mm to 1000 mm in width and of weight between 61 kg to 80 kg and fixed complete all as specified. |
| 36 | Material and labour for 18/19 mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work complete all as specified. |
| 37 | Supply and fix 5.5 mm thick sheet glass ,ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each panecomplete all as specified. |
| 38 | Material and labour for for suspended false ceiling using grid 180 GSM (exposed ceiling suspension system ) of grid size 605 mm x 605 mm with main runner 38 mm x 24 mm and wall angle 24 mm x 24 mm using 12 mm thick gypsum board in a grid of powder coated GI system duly suspended with 12 mmdia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1210 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450 mm from the adjacent wall, Flush fitting 1210 mm cross tee to be interlocked between main runners @ 605 mm c/c,so as to form 600 mm x 600 mm grid complete all as specified . Make: Everest/ Lafarge/ Armstrong |
| 39 | Supply and fix pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 40 | Supply and fix pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 41 | Material and labourfor walling random rubble uncoursed well bonded, bedded and solidly hearted built in cement mortar 1:6 as in retaining walls, wing walls, abutment and the likes complete all as specified.Note: Precast PCC bond stone will be measured and paid seperarely against item here-in-after |
| 42 | Labouronly walling random rubble uncoursed well bonded, bedded and solidly hearted built in cement mortar 1:6 as in retaining walls, wing walls, abutment and the likes complete all as specified.Note: (a) Precast PCC bond stone will be measured and paid seperarely against item here-in-after(b) Material for cement mortar are deemed to be included this item. |
| 43 | Material and labour for providing, precast cement concrete 1:2:4 type B1 using 20 mm graded crushed stone aggregates as in, bond stone for stone walling,set in cement mortar 1:6 complete with joints to match complete all as specified. |
| 44 | Supply and fix 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in walls as in weep holes including all fittings i.e. junction, Tee, bend if required. Complete all as specified. |
| 45 | Material and labour for loose fillingback of weep holes with 40mmto 80mm graded stone aggregates, complete all as specified. |
| 46 | Supply and fix galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks,or galvanised wire staples to hold aggregates or as directed by Engineer-In-Charge.. |
| 47 | Material and labour for providing, cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregatesas in , copings,and as directed by Engineer-In-Charge. |
| 48 | Extra over stone walling, random rubble brought upto courses, for hammer dressing to face stones and dressing of face beds and joints, with maximum depressions on face from straight edge held against the dressed surface not exceeding 40 mm on lime or sand stone complete all as specified. |
| 49 | Material and labour raised pointing to random or polygonal rubble, uncoursed in cement mortar 1:4 on brought upto courses complete all as specified. |
| 50 | Material and labour forpreparation of new wall surfaces and applying two coats of cement base paint over one coat of external primer paint to external walls including complete all as specifies and directed |
| 51 | Material and labour for providing cement concrete 1:2:4type B1with using 20 mm graded stone aggregates as in surface channel and drain complete all as specified. |
| 52 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.complete all as specified. |
| 53 | Material and labour for 10 mm thick renderingin cement mortar 1:6 on fair faces of brick wall or concrete surfaces, finished the surfaces even and smooth without using extra cement including taking down cement plaster complete all as specified. |
| 54 | Material and labour for pre-cast cement concrete block masonry with solid blocks 1:3:6 type C1 20 mm graded crushed stone aggregates, exceeding 10 cm in width and setting in cement mortar 1:4, complete all as specified.Note: Formwork shall be paid including this item but reinforcement shall be measured and paid separately. |
| 55 | Supply and fix Mild steel TMTbars 10 mm dia and over cut to length and bent to shape as reqd, including cranking , bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed ) not less than 0.90 mm dia complete all as speified and directed . |
| 56 | Supply and fix as in repairs framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified. |
| 57 | Taking down carefully LT UG cable of size 50 to 70 sqmm 3.5 to 4 core and stacking in MES storeyard all as directed by Engineer-In-Charge.Note: Excavation work shall be measured and paid separately. |
| 58 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 10 Sqmm 2.0 Core laid in trenches / ducts/ inside protection pipeincluding cable glands, lugs and suitable size of MS saddle clips etc. all as directed by Engr-In-Charge.Make: Polycab(ISI Marked)/ Finolex(ISI Marked)/ Havells (ISI Marked)/ KEI (ISI Marked)/ Gloster (ISI Marked)Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 59 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 50 Sqmm 4.0 Core laid in trenches / ducts/ inside protection pipeincluding cable glands, lugs and suitable size of MS saddle clips etc. all as directed by Engr-In-Charge.Make: Polycab(ISI Marked)/ Finolex(ISI Marked)/ Havells (ISI Marked)/ KEI (ISI Marked)/ Gloster (ISI Marked)Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 60 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 35 Sqmm 3.5 Core laid in trenches / ducts/ inside protection pipeincluding cable glands, lugs and suitable size of MS saddle clips etc. all as directed by Engr-In-Charge.Make: Polycab(ISI Marked)/ Finolex(ISI Marked)/ Havells (ISI Marked)/ KEI (ISI Marked)/ Gloster (ISI Marked)Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 61 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 16 Sqmm 3.5 Core laid in trenches / ducts/ inside protection pipeincluding cable glands, lugs and suitable size of MS saddle clips etc. all as directed by Engr-In-Charge.Make: Polycab(ISI Marked)/ Finolex(ISI Marked)/ Havells (ISI Marked)/ KEI (ISI Marked)/ Gloster (ISI Marked)Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 62 | Supply and fix cable jointing kit for 1.1 KV grade cable for end joint complete with jointing materials heat shrink type and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 240 to 300 sqmm, indoor/ outdoor type complete all as directed by Engineer-In-Charge.Make: M-Seal/ Cab-Seal/ Denson/3M |
| 63 | Supply and fix cable jointing kit for 1.1 KV grade cable for end joint complete with jointing materials heat shrink type and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 150 to 185 sqmm, indoor/ outdoor type complete all as directed by Engineer-In-Charge.Make: M-Seal/ Cab-Seal/ Denson/3M |
| 64 | Supply and fix cable jointing kit for 1.1 KV grade cable for end joint complete with jointing materials heat shrink type and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 70 to 120 sqmm, indoor/ outdoor type complete all as directed by Engineer-In-Charge.Make: M-Seal/ Cab-Seal/ Denson/3M |
| 65 | Supply and fix cable jointing kit for 1.1 KV grade cable for end joint complete with jointing materials heat shrink type and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 25 to 50 sqmm, indoor/ outdoor type complete all as directed by Engineer-In-Charge.Make: M-Seal/ Cab-Seal/ Denson/3M |
| 66 | Supply and fix cable jointing kit for 1.1 KV grade cable for end joint complete with jointing materials heat shrink type and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 06 to 16 sqmm, indoor/ outdoor type complete all as directed by Engineer-In-Charge.Make: M-Seal/ Cab-Seal/ Denson/3M |
| 67 | Supply and fix as in replacement sheet metal enclosure MCB DB SPN with 200 Amp rated bus bar 2 way 240 V (single door type) with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonry etc. and making good of disturbed surface to match with existing colour of wall complete all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GENote: (a) Quoted rates shall be deemed for brick wall / concrete wall cutting and making good as per existing surfaces. |
| 68 | Supply and fix as in replacement sheet metal enclosure MCB DB SPN with 200 Amp rated bus bar 4 way 240 V (double door type) with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonry etc. and making good of disturbed surface to match with existing colour of wall complete all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GENote: (a) Quoted rates shall be deemed for brick wall / concrete wall cutting and making good as per existing surfaces. |
| 69 | Supply and fix as in repair MCB SPN 240 volts, 50 Hz capacity 6-32 Amps \"C\" curve all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GE |
| 70 | Supply and fix as in repair MCB SP 240 volts, 50 Hz capacity 6-32 Amps \"C\" curve all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GE |
| 71 | Supply and filling for dry sand in cable protection trenches before and after the cables are laid, for sand cushioning to cables complete all as specified and directed. NOTE : thickness after punning of sand shall be (minimum as specified in SSR) measured and paid in this item. |
| 72 | Labour for boring under road, manually suitable for inserting 50 mm bore pipe at a depth 0.5 mtr to 1.0 mtr complete all as directed by Engineer-In-Charge. |
| 73 | Material and labour for brick protection for UG XLPE cable with burnt clay old size sub class \"B\" bricks laid dry and flat abutting each other with gaps between adjacent brick not more than 10mm and width equal to length of brick in trenches across the cable complete all as directed by Engineer-In-Charge.Make: Best quality locally available which is duly approved by GE. |
| 74 | Material and labour for tubes \"light grade\" galvanised with all fittings laid in trenches of 50 mm bore dia. Make : Tata / Jindal Steel / Prakash/ Surya Roshni ltd |
| 75 | Supply and fix gong bells single phase 220/250 V of size 380 cm with connecting wire and accessories (i.e clamps, bolts, board etc.) as per manufacturer instruction. |
| 76 | Material and labour forSub main wiring with PVC insulated unsheathed two run of 4.00 Sq. mm single core multistand copper conductor cable (FRLSH), 1100 volt grade alongwith one run of 4.00 sqmm PVC insulated and unsheathed copper conductor cable (FRLSH) 1100 volt grade, connected to common earth dolly as earth continuity conductor, drawn through 25 mm x 16 mm PVC casing caping including taking out existing wiring complete all as specified and directed.Note: (a)PVC casing \"N\" caping including accessoriesshall be measured measured and paid including the item.(b) 2 Run of line conductor and 1 Run of earth continuity conductor shall be measured as one unit length.(c) Cable requireds for connection to MCBs/DBs shall be deemed to be included in the unit rate.(d) The Payment shall only be allowed after production of original GST defaced purchase vouchers by Engr- In- ChargeMake: Havells(ISI Marked)/ Plaza(ISI Marked)/ KEI(ISI Marked) |
| 77 | Supply, installation, testing & commissioning CPRI approved outdoor cubical type LT feeder pillar box suitable for 415V, 3 phase , 4 wire 50 Hz, AC supply system fabricated outer shell from MS sheet 3.15 mm thick and MS angle of size 50 mm x50 mm x6 mm frame front and back openable single door system lockable /openable by keys from both sides having lock system totally enclsoed dust, weather & vermin proof having and inner shell 2mm thick made of MS sheet compartmentlisedfor each control gear front openable single door system lockable/openable by keys having louvers and air vent gaskets for natural flow of Air. \"U\" type gasket shall be used to make the inner shell completely vermin proof and to accomodate incommer/outgoing MCCBs andTPN copper busbars of rating 1.5 times that of controlling MCCB. TPN busbar and extension link shall be insulated with color coded heat shrinkable sleeve and shall be mounted on suitable size SMCinsulator at suitable inteval throghout the length of TPN busbar.supported on SMC insulator, bottom base channel of MS section not less than 100mm x50mm x5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switchgears with required size of copper bus bars. All control wiring with minimum 1.5 sqmm PVC insulated multistranded copper conductor cable, cable alleys, cable gland, plates in two halfand general construction confirming to IS:8623/93. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided on the busbar chamber and front of outer shell and The degree of protection of outer shell shall be IP-54 and mountedon suitable PCC foundation. A detechable pre drilled gland plate of thickness 3mm should be used at bottom shell.Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the feeder pillat box safely shall be made. Indicating lamps LED type, 230volts, AC at the incomer of the unit to show three phase availability at the outgoing of incomer including tamper proof digital meter to measure voltage, current with CT & PT (Make- Secure/L&T/HPL/Schneider). An inspection lamp with 5 watt LED bulb shall be fitted on top side of inner shell. The degree of protection for inner shell shall be IP-42 & including carry the following controls :- Note: Contractor shall be submit feeder pillar box drawing before placing order and approved from GE. |
| 78 | INCOMING(a)MCCB, adjustable type thermal magnetic release type,4 poles, 415 Volts,Ics = 100% Icu, Lcu = 50 KA breaking capacity, rating 250 Amps including all fixing accessories with both ends spreader links - 01 No. Make :- Siemens / Legrand / Schneider/ ABB |
| 79 | (b) Supply and fixing changeover switch C-line type 250 Amps open execution type ,415 volt,50 cycles complete with operation handle. Make :- ABB / Legrand / Schneider/Siemens |
| 80 | (c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC -01 set (set of three) Make :- ABB / Legrand / Schneider/Siemens. |
| 81 | (d)Digital Ammeter of range (0-400) Amps, flush mounting type of size 100mm x 100mm (4”x4”) square dial with CT’s of ratio 100/5 and selector switch – 01 set. Make :- ABB / Legrand / Schneider/Siemens |
| 82 | (e)Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No. Make :- ABB / Legrand / Schneider/Siemens |
| 83 | OUTGOING (a) MCCB, adjustable type thermal magnetic release type,3 poles, 415 Volts,Ics = 100% Icu, Lcu = 25 KA breaking capacity, rating 125 Amps including all fixing accessories with both ends spreader links - 02 Nos. Make :- ABB / Legrand / Schneider/Siemens |
| 84 | (b) MCCB, adjustable type thermal magnetic release type,3 poles, 415 Volts,Ics = 100% Icu, Lcu = 25 KA breaking capacity, rating 63 Amps including all fixing accessories with both ends spreader links - 02 Nos. Make :- ABB / Legrand / Schneider/Siemens |
| 85 | (c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC -04 set (set of three) Make :- ABB / Legrand / Schneider/Siemens. |
| 86 | (d)Spare pocket for 02 Nos MCCB. |
| 87 | Supply, installation, testing & commissioning CPRI approved outdoor cubical type LT feeder pillar box suitable for 415V, 3 phase , 4 wire 50 Hz, AC supply system fabricated outer shell from MS sheet 3.15 mm thick and MS angle of size 50 mm x50 mm x6 mm frame front and back openable single door system lockable /openable by keys from both sides having lock system totally enclsoed dust, weather & vermin proof having and inner shell 2mm thick made of MS sheet compartmentlisedfor each control gear front openable single door system lockable/openable by keys having louvers and air vent gaskets for natural flow of Air. \"U\" type gasket shall be used to make the inner shell completely vermin proof and to accomodate incommer/outgoing MCCBs andTPN copper busbars of rating 1.5 times that of controlling MCCB. TPN busbar and extension link shall be insulated with color coded heat shrinkable sleeve and shall be mounted on suitable size SMCinsulator at suitable inteval throghout the length of TPN busbar.supported on SMC insulator, bottom base channel of MS section not less than 100mm x50mm x5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switchgears with required size of copper bus bars. All control wiring with minimum 1.5 sqmm PVC insulated multistranded copper conductor cable, cable alleys, cable gland, plates in two halfand general construction confirming to IS:8623/93. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided on the busbar chamber and front of outer shell and The degree of protection of outer shell shall be IP-54 and mountedon suitable PCC foundation. A detechable pre drilled gland plate of thickness 3mm should be used at bottom shell.Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the feeder pillat box safely shall be made. Indicating lamps LED type, 230volts, AC at the incomer of the unit to show three phase availability at the outgoing of incomer including tamper proof digital meter to measure voltage, current with CT & PT (Make- Secure/L&T/HPL/Schneider). An inspection lamp with 5 watt LED bulb shall be fitted on top side of inner shell. The degree of protection for inner shell shall be IP-42 & including carry the following controls :- Note: Contractor shall be submit feeder pillar box drawing before placing order and approved from GE. |
| 88 | INCOMING(a)MCCB, adjustable type thermal magnetic release type,4 poles, 415 Volts,Ics = 100% Icu, Lcu = 50 KA breaking capacity, rating 250 Amps including all fixing accessories with both ends spreader links - 01 No. Make :- Siemens / Legrand / Schneider/ ABB |
| 89 | (b)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC -01 set (set of three) Make :- ABB / Legrand / Schneider/Siemens. |
| 90 | (c)Digital Ammeter of range (0-400) Amps, flush mounting type of size 100mm x 100mm (4”x4”) square dial with CT’s of ratio 100/5 and selector switch – 01 set. Make :- ABB / Legrand / Schneider/Siemens |
| 91 | (d)Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No. Make :- ABB / Legrand / Schneider/Siemens |
| 92 | OUTGOING (a) Aluminium bus bar of suitable rating-04 Sets |
| 93 | Material and labour for point wiring with 1.50 Sqmm PVC insulatedun sheatned multi stranded copper conductor cable (FRLSH) 1100 volts grade two single core conforming to IS-694-1990 and one run of continious earth wire with 1.50 Sqmm PVC insulated unsheatned stranded copper conductor cable (FRLSH) draw in and including heavy duty 20 mm dia PVCconduit(ISI marked) in concealed with all necessaryfittings and fixures with GI sunken boxes with earth dolly and 3 mm laminated cover sheet suitable for fixing switch, socket, regulator, fan point, exhaust fan point etc. including making good disturbed surface with CM (1:4) to match with the existing surface complete all as specified for the following :- Note:-(a) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing.Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.(b) Quoted rates shall be deemed for conduit,cover plate and box of suitable module, cutting chases of wall, making good disturbed wall.Make: Finolex(ISI Marked)/ Polycab(ISI Marked)/ Nicco (ISI Marked)/ Havells (ISI Marked)/ RR Cable(ISI Marked)/ KEI (ISI Marked) |
| 94 | One light/ fan point/ call bell controlled by one, one way switch |
| 95 | One 5 pin 6 Amps switch socket outlet point controlled by one switch on independent board. |
| 96 | All as per Item No 79.00 but One 3 pin socket outlet. 15 amps, independent, with cables 4 sq. mm size complete all as specified. |
| 97 | Supply and fix as in repairs ceiling rose surface baklite with three terminals 240 V.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 98 | Supply and fix as in replacement sheet metal enclosure MCCB DB TPN with 160 Amp rated bus bar 4 way 415 V (double door type) with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonry etc. and making good of disturbed surface to match with existing colour of wall complete all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GENote: (a) Quoted rates shall be deemed for brick wall / concrete wall cutting and making good as per existing surfaces. |
| 99 | Supply and fix as in repair MCB SP 240 volts, 50 Hz capacity 6-32 Amps \"B\" curve all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GE |
| 100 | MCCB, adjustable type thermal magnetic release type,4 poles, 415 Volts,Ics = 100% Icu, Lcu = 25 KA breaking capacity, rating 125 Amps including all fixing accessories with both ends spreader links. Make :- Siemens / Legrand / Schneider/ ABB |
| 101 | Supply and fix as in replacement LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specifed and directed.Make:- Crompton / Bajaj/ Philips/ Havells/ Osram/ Wipro/ GE Note:- (a) LM-79 and LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minium 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 102 | Supply and fix as in repairs Switch piano, flush type single pole one way 6 Amps 240V.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 103 | Supply and fix as in repairs switch socket combination, 2 in 1, 5 pin 6 Amps 240 V ,flush type.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 104 | Supply and fix as in repairs Switch piano, flush type single pole one way 16 Amps 240V.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 105 | Supply and fix as in repairs switch socket combination, 2 in 1, 5 pin 10 Amps and 20 Amps 240 V ,flush type.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 106 | Supply and fix in replacement LED floodlight of 50 Watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs with IP66 protection.Make: Crompton / Bajaj/ Philips/ Havells/ Osram/ Wipro/ GE Note:- (a) LM-79 and LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings to the Engineer-In-Charge.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minimum 50000 Hrs to the Engineer-In-Charge.(c) LED light fitting and drivers shall be of same make. |
| 107 | Supply and fix in replacement LED bollard of 9-10 Watts, 240V, 50Hz IP 65 tripod type.Make: Crompton / Bajaj/ Philips/ Havells/ Osram/ Wipro/ GE Note:- (a) LM-79 and LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings to the Engineer-In-Charge.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minimum 50000 Hrs to the Engineer-In-Charge.(c) LED light fitting and drivers shall be of same make. |
| 108 | Supply and fix in replacement LED Post top lantern of 60 Watts, 240V, 50Hz IP 65 made of black ABS plastic spigot, spun aluminium funnel shape with clear acrylicand accessories such as integrated drivers pre-wired etc suitable with gate lightpipe.Make: Crompton / Bajaj/ Philips/ Havells/ Osram/ Wipro/ GE Note:- (a) LM-79 and LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings to the Engineer-In-Charge.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minimum 50000 Hrs to the Engineer-In-Charge.(c) LED light fitting and drivers shall be of same make. |
| 109 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 4 Sqmm single core multistrand copper conductor cable (FRLSH), 1100 Volt grade alongwith single run of 4 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH) 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through minimum 20 mm PVC conduit complete all as specified.Note:- (a)PVC conduit in concealed including accessories shall be measured and paid including the item.(b) 2 Run of line conductor and 1 Run of earth continuity conductor shall be measured as one unit length.(c) Cable requireds for connection to MCBs/DBs shall be deemed to be included in the unit rate.(d) Rate shall be included for cutting, pinning in, making good to facings where required for pointing in cement mortar 1:3 and cutting chases for concealed conduit wiring and making good, and cutting not exceeding 10 cm girth.Make: Finolex(ISI Marked)/ Polycab(ISI Marked)/ Nicco (ISI Marked)/ Havells (ISI Marked)/ RR Cable(ISI Marked) |
| 110 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 6 Sqmm single core multistrand copper conductor cable (FRLSH), 1100 Volt grade alongwith single run of 6 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH) 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through minimum 20 mm PVC conduit complete all as specified.Note:- (a)PVC conduit in concealed including accessories shall be measured and paid including the item.(b) 2 Run of line conductor and 1 Run of earth continuity conductor shall be measured as one unit length.(c) Cable requireds for connection to MCBs/DBs shall be deemed to be included in the unit rate.(d) Rate shall be included for cutting, pinning in, making good to facings where required for pointing in cement mortar 1:3 and cutting chases for concealed conduit wiring and making good, and cutting not exceeding 10 cm girth.Make: Finolex(ISI Marked)/ Polycab(ISI Marked)/ Nicco (ISI Marked)/ Havells (ISI Marked)/ RR Cable(ISI Marked) |
| 111 | Material and labour for earthing complete with galvanised steel earth plate electrode 60 cm × 60 cm.× 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified. |