Tender For Special Repair To Bldg No P-88 (Squash Court), Spl Repair To Bldg No T-20 (Sqm Store), Special Repair To Bld No T-4 And Po Of Qty 35 Steel Sink At Govt Accn At Ratnuchak Mil Stn Under Ge Kaluchak, kaluchak-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Special Repair To Bldg No P-88 (Squash Court), Spl Repair To Bldg No T-20 (Sqm Store), Special Repair To Bld No T-4 And Po Of Qty 35 Steel Sink At Govt Accn At Ratnuchak Mil Stn Under Ge Kaluchak. Submission Date for this Tender is 26-12-2023. Building Work Tenders in kaluchak Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

40835712
Corrigendum : Tender For Special Repair To Bldg No P-88 (Squash Court), Spl Repair To Bldg No T-20 (Sqm Store), Special Repair To Bld No T-4 And Po Of Qty 35 Steel Sink At Govt Accn At Ratnuchak Mil Stn Under Ge Kaluchak
Open Tender
Indian
Jammu And Kashmir
kaluchak
26-12-2023

Tender Details

Tender For Special Repair To Bldg No P-88 ( Squash Court ) , Spl Repair To Bldg No T-20 ( Sqm Store ) , Special Repair To Bld No T-4 And Po Of Qty 35 Steel Sink At Govt Accn At Ratnuchak Mil Stn Under Ge Kaluchak

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
INR 48 Lakhs /-

BOQ Items

NAME OF WORK : SPL REPAIR TO BLDG NO P-88(SQUASH COURT),SPL REPAIR TO BLDG NO T-20(SQM STORE),SPL REPAIR TO BLD NO T-4 AND P/O OF QTY 35 STEEL SINK AT GOVT ACCN AT RATNUCHAK MIL STN UNDER GE KALUCHAK
Sl. No. Item Description
1Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
2Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
3Taking down shutters of any descriptionnot exc. 1 Sqm each, complete all as specified & directed.
4Demolition of brick work or stone / bouldermasonry includingall quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed.
5Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
6Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
7Dismantling of structural steel work including doors, gates but excluding framed trusses complete all as specified and directed.
8Dismantling of asbestos cement (corrugated, semicorrugated,etc.)sheets in roof coverings complete all as specified and directed.
9Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
10Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
11Dismantling of water tank exc. 500 Litre but not exc. 1000 Litre capacity complete all as specified and directed.
12Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
13Dismantling of timber fillet, rails, post, rafters, purlins, etc. under 40 Sqcm in section unframed or framed work complete all as specified and directed.
14M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-0, using 12.50 mm graded stone aggregate, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed platesetc and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
15M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
16Cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, lintels, shelves etc, and cutting chases for concealed water tubing or concealed conduit wiring etc, and making good on brick walls, cutting not exc. 10 cm in girth complete all as specified and directed.
17Cutting holes into or through brick walls( Superficial area Exc 150 Sq.cm but n exc 400 sq.cm)built in cement mortar and making good the same in cement concrete 1:2:4 type B-1 or cement mortar 1:3 as required,complete all as specified and directed.
18S & F of solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain coloured PVC sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
19S & F of 35 mm thick (Batten thickness) 2nd hardwood(Sal/ Hollock) plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged) or of 12 mm thick veneered particle board medium density, wood particle board with commercial face veneers and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule 2009, part – I (Specifications) complete all as specified and directed.
20S & F of 30 mm thick (style thickness) factory made solid panel PVC shutter consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheets beading and joined together with solvent cement as per specification and drawinggiven on MES schedule Part – II (2010) complete all as specified and directed.
21S & F of factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site complete all as specified and directed.
22S & F of 250 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy and fixed in repair complete all as specified and directed.
23S & F of 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
24S & F of 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
25S & F of 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
26S & F of 140 mm size (Overall length of cover plate) floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
27S & F of rolled mild steel sections as in main and cross beams, hip and jack rafter, purlins where connected to common rafters, running rails, guides for sliding doors fixed with angle cleat and other connecting plates conforming to Fe-290 (Gde E- 165) complete all as specified and directed.
28S & F of rolled mild steel plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming Fe 410 -W(Gde-E- 250)complete all as specified and directed.
29S & F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantry, rails, fastening, heavy bracket framing (Beam, tee, angle, channel or flat section), including distance pieces, cleats etc. confirming to Fe 410 -W(Gde-E- 250) quality-B including cutting, welding etc. complete all as specified and directed.
30S & F of mild steel screw bolts of diameter of neck exc 12 mm but n.exc 20 mm (machine made) with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed ends to be fitted with washer and one hexagonal or square nut,not exc. 30 cm longcomplete all as specified and directed.
31S & F of pressed steel frames of size 105 mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate., complete all as specified & directed. NOTE : PCC for filling of hollow portion shall be measured and paid for separately.
32S&F of anodised aluminium with powder coating (minimum thickness 50 micron) door shutter, rails (top, middle and style ) of size 82.53 x 44.45mmand bottom rail of size 114.30 x 44.45mm made out of 1.6mm thick aluminium sheet/section including necessary jointing cleats, glazing clips, rubber packing, mortice lock having six levers, aluminium body hydraulic door closer of suitable size, handles 2 Nos in each shutter, tower bolt, hinges etc., anodised aluminium snap beading screws, complete all as specified & directed. Note : Sheet glass will be measured and paid separately under respective item..
33S&F of anodised aluminium with powder coating window/ventilator shutter, section of size 44.45 x 44.45mm made out of 1.6mm thick aluminium sheet/section including necessary jointing cleats, glazing clips, rubber packing, suitable handle 1 No in each shutter, tower bolt, hinges 110mm long, anodised aluminium snap beading screws, complete all as specified and directed. Note : Sheet glass will be measured and paid separately under respective item.
34S&F of PVC hollow profile 12mm thickness design and pattern as approved / directed at site, complete all as specified and directed.
35M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.complete all as specified and directed.
36M&L for drilling and taping dia of holes drilled exc 12 mm and n.exc. 25 mmcomplete all as specified and directed.
37S & F of Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roofcovering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed .NOTE:- Corrugated shape of sheet shall be approved by GE
38S & F of Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed . NOTE:- Corrugated shape of sheet shall be approved by GE
39M & L for 15 – 18 mm thick machine cut Kota stone slab as in flooring over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish complete all as specified and directed.NOTE: - SCREED SHALL BE MEASURED AND PAID SEPARATELY.
40M & L for 75 mm thick cement concrete 1:3:6 type C-1, using 20 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm thick joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed.
41M & L for providing cement concrete 1:2:4 type B-0 (using 12.50 mm thick graded stone aggregate) as in roof padding even and fair complete all as specified and directed.
42Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, and brushing neat cement slurry with 3.0Kg of cement per square metre, complete all as specifed & directed.
43S & F for Vitrified lightshade Ceramic tiles 9-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.NOTE: - SCREED SHALL BE MEASURED AND PAID SEPARATELY.
44S & F for Vitrified light shade Ceramic tiles 9-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as on vertical surface of wall such as skirting, dado, riser etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - RENDERING SHALL BE MEASURED AND PAID SEPARATELY.
45M & L for 15 to 18 mm thick granite (of any type and shade) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4)including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including necessary cutting, grinding, rubbing, polishing rounding to exposed edgesand laid over20 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed.
46M & L Non - skid joint free Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.NOTE: - SCREED SHALL BE MEASURED AND PAID SEPARATELY.
47M & L for Glazed ceramic coloured tiles in vertical surface 450x300x 7 mm thick , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - RENDERING SHALL BE MEASURED AND PAID SEPARATELY.
48M & L Non - skidjoint free ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.16 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.NOTE: - SCREED SHALL BE MEASURED AND PAID SEPARATELY.
49M & L forapplication of anti-termite treatment of the floor, laying 6 mm thick KDPE sheet with overlapping of minimum 15 cm to act as vapour barrier, fixing of AERO FLOAT 10 mm cushion pads at a distance of 350 mm c/c, providing runners of 44mm/ 45mm x 70mm/ 71mm at distance of 350mm c/c and finally laying 20mm thick Action Wooden Flooring followed by standing the wooden flooring and application of MFMA approved “Poloplaz” “Matt Finish” sports polish consisting of one sealer coat and two top coats including removing of existing wooden flooring all as specified and directed
50M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth (without using extracement)complete all as specified and directed.
51M & L for 5 mm thick rendering on fair faces of brick work or concrete surfaces of ceiling with cement mortar 1:4 finished even and smooth (without using extracement)complete all as specified and directed.
52M & L for 5 mm thick rendering on fair faces of brick work or concrete surfaces of ceiling ( Approx height of 7.00 M) with cement mortar 1:3 finished even and smooth (without using extracement)complete all as specified and directed.
53M & L for 15 mm thick rendering in two layers on fair faces of brick work or concrete surfaces first layers 10 mm thickwith cement mortar 1:6 on fair faces of brick work or concrete surfaces and second layers 5 mm thickwith cement mortar 1:4 with mixing of water proofing compound as per manufacturer’s instructions complete all as specified and directed. NOTE: - (i)WATER PROOFING COMPOUNDSHALL BE MEASURED AND PAID SEPARATELY.
54Supply only water proofing compound ( (Liquid)complete all as specified.
55M & L for 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed.
56M & L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough suitable for laying wall tiles complete all as specified and directed.
57Taking down cementplaster and decayed concrete of any description,upto triple storey of building from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with integral water proofing compound orPCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate including necessary form work/scaffolding where ever required, rendering with 15 mm thickcement mortar 1:3, surface finished even and smooth without using extra cementusing integral water proofing compound as per manufacturer,s instructions , complete all as specified & directed. NOTE:-Integral water proofing compound shall be measured & paid seprately.
58Hacking out old broken glass (any thickness, size, qualityor description) from wooden / metal frames, glazed with oil putty or fixed with beads including punching or drilling out old glazing pins / spring clips and providing and fixing new ones complete allas specified and directed.
59S & F of 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
60S & F of 3 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane with oil putty or fixed with beads complete all as specified and directed.
61S & F of 5mm thick tinted glass as in aluminium door/ window/ ventilator with aluminium hollow beading/ glazing clip size 19mm x 17mm made out of 0.70mm thick hollow section weighing not less than 0.97 Kgs/RM including rubber gasket,complete all as specified & directed..
62S&F for 12mm micron clear toughened glass with 4 panels 1 door, 4 fins, fixtures & fittings including all other materials for erecting the glass wall system for glass back wall of Squash Court. Size = 7’x21’.complete all as specified & directed..
63M & L for complete removal of old finishes from walls by scrapping, rubbing down, with sand paper to have even and smooth surfaces and applying two coats ofcement base paint over one coat of water proofingprimer complete all as specified and directed.
64M & L for preparation of old decorated plastered or unplastered surfaces of walls, cornices etc by brooming down or steel wire brushing downscrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coats of white wash complete all as specified and directed.
65M & Lfor preparation of old decorated plastered or unplastered surfaces of ceiling, cornices etc by brooming down or steel wire brushing downscrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots,and applying one coats of white wash complete all as specified and directed.
66M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
67M & L for preparing newly plastered or previously untreated on RCC Chajjas roof projecation side fins and applying two coats of cement base paint over one coat ofwater proof primer complete all as specified and directed.
68M&L for preparation of old decorated plastered or unplastered surfaces of walls, cornices etc by brooming down or steel wire brushing downscrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coats of cement base paint complete all as specified and directed.
69M & L for preparing newly plastered or previously untreated wall surfaces and applying two coat of oil bound distemper over one coat of water proofprimer complete all as specified and directed.
70M&L for preparation of old decorated plastered or unplastered surfaces of wall, cornices etc by brooming down or steel wire brushing downscrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coats of oil bound distempercomplete all as specified and directed.
71M & L for preparation of new or previously untreated brick, stone, concrete, asbestos cement or plastered surfaces over 10 cm width or girth and applying two coats of plastic emulsion paint over a coat of priming paint plaster complete all as specified and directed.
72M & L for complete removal of old finishes from walls by scrapping, rubbing down, with sand paper to have even and smooth surfaces and applying two coats of oil bound distemperover a coat of 1 mm thickbirla wall care putty complete all as specified and directed.
73M & L for preparation of new or previously untreated wooden surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
74M & L for preparation of new or previously untreated wooden surfaces of any description n exc 10cm width or girth and applying two coats of synthetic enamel paintwhen unconnected with other painting or when painted in different tint complete all as specified and directed.
75M & L for preparation of new or previously untreated wooden surfaces of any description and line marking withtwo coats of synthetic enamel paint on wall surface of different tint (any size) complete all as specified and directed.
76M&L for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth including knotting and stopping and applying one coat of synthetic enamel paint (any tint/Shade) complete all as specified and directed.
77M&L finishing walls with Acrylic Smooth exterior paint weather proof paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) complete all as specified and as directed
78M&L for preparation of old painted steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint (any tint/shade) complete all as specified and directed
79M&L for rebound hard plaster conforming to requirements of WSF (15mm total thickness including based coat) with imported washable paint systemcomplete all as specified and directed
80S & F of 500 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position complete all as specified and directed.
81Taking up or down 15 mm bore steel water tubing and connection, including cleaning for refixing or removal to store complete all as specified and directed.
82Taking up or down 20 mm bore steel water tubing and connection, including cleaning for refixing or removal to store complete all as specified and directed.
83Fixing only 15 mm bore old steel water tubing and connection in new or old position to wall and ceiling or laid in floors jointing and testing of old retrieved serviceable galvanized mild steel water tubing with and including all fitting (such as bends, elbows, tees, short pieces, connectors, back nuts, deminishing pieces caps, plugs and union etc) complete all as specified and directed.NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM.
84S&F 15mm nominal bore of pipe in walls, and ceiling or laid in floors, jointing and testing galvanised mild steel water tubing “medium grade” with and including all fitting (such as bends, elbows, tees, short pieces connectors, back nuts, diminishing pieces, capas, plugs and union etc) complete all asspecified and directed.
85S&F 20 mm nominal bore of pipe in walls, and ceiling or laid in floors, jointing and testing galvanised mild steel water tubing “medium grade” with and including all fitting (such as bends, elbows, tees, short pieces connectors, back nuts, diminishing pieces, capas, plugs and union etc) complete all asspecified and directed.
86Cutting & screwing of existing existing steel tubing for inserting tee etc of suitable size for making branch connection of15 mm dia including testing after completion, complete all as specified & directed.
87S & F of 15 mm bore chromium plated,fancy type bib tap,with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
88S&F fancy type angular stop cock with flange, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, externally threaded,screwed both ends for iron pipe or for unions of 15mm bore complete all as specified and directed.
89S & F of 15 mm bore fancy type, chromium plated stop valve, with long shank and cup (Concealed Type) cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
90S & F of20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed.
91S & F in repairs 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
92S & F of 100 mm dia grating doom of chromium plated complete all as specified and directed.
93S & F of soap dish, chromium plated brass screws, approximate size 160x 160x90mm embedded in the wall complete all as specified and directed.
94S & F of toilet paper holder of vitreous china box typewith chromium plated (CP) brass screws embedded in the wall complete all as specified and directed.
95S&F in repair drapery fancy type curtain rod shall be 32 mm dia of aluminium pipe with powder coating with wooden finish including bracket rings,fancy knob , curtai ring 08 Nos minimumincluding all fixing arrangement complete all as specified and directed.
96S & F in repair20 mm dia brass chromium plated tubular towel rail "D" type 60 cm long between flanges, including one pair of fixing brackets complete all as specified and directed.
97S & F of 32 mm size (Dia of discharge pipe) waste coupling of PTMT half or full threaded (minimum weight 45 gram) complete all as specified and directed.
98S&F 15 mm bore angle stop valve cast copper alloy,CP with capstan heads, fancy type any colour high pressure screwed for iron pipe and fixed complete all as specified and directed.
99S & F of 15 mm bore fancy type pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered "HOT" or "COLD’ with long screwed shank and fly nuts, screwed for iron pipe complete all as specified and directed.
100S&F in repair brass CP mixer for mixing hot & cold water screwed down for15 mm dia bore GI pipe complete all as specified and directed.
101S & F of brass chromium plated standard quality jet system suitable for European water closet complete all as specified and directed.
102S & F of 15 mm size hand shower(Heath faucet, ABSchromium plated) with 8 mm dia, 1 meter long flexible tube & wall hook complete all as specified and directed.
103S & F of double bowel 1 mm thick stainless steel sink with drainage board Kitchen or laboratory type with plug washer and waste including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, over all size of sink 915 mm X 460 mm and bowl size 410 mm X 330 mm X 160 mm complete all as specified and directed.
104S&F of sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 405mm x 355mm x 178mm complete all as specified and directed.
105Viterous china urinal, half stall type flat back, size 465x355x265mm (minimum) white with grating and union for discharge pipe, complete including providing and fixing plugs, beding urinal against wall in cement mortar 1:2 securing urinal plugs with and including 60mm long brass screws, pointing around urinal back in cement, complete all as specified & directed.
106S & FViterous china urinal partition white of size 310x700 mm fixed to wall with connecting screws or bolt or any type with all fitting and fixture complete all as specified and directed.
107S&Fof vitreous china wash basin 550 x 400 mm size, coloured flat back or angle back, including brackets, CP waste coupling, PVC waste pipe etc and fixing of pillar taps including cutting for and pinning in the ends of brackets complete all as specified and directed.
108S & F in repair vitreous china wash down water closet pan (Pedestal pattern)and trap (excluding) fixing bolts,flushing cistern and flush pipe including connection to drain (or outgoing pipe)including plastic seat cover suitable for water closet pedestal pan, coloured closed pattern with flat bottom and cover and mid steel chromium plated or aluminium hinges devices with and includingbrass chromium plated standard quality jet with nozzle 1500 mm long PVC pipe etc complete all as specified and directed complete all as specified and directed.
109S & F of vitreous china one piece square ceramic Europen type water closet with seat coverand twin flush fitting including necessary traps and connection to drain and flushing pipe etc of size 520x350x410mmcomplete all as specified and directed.
110S & F of vitreous china, one piece wash hand basin, with integrated half pedestal complete fixed to wall with rag bolts including cutting for and pinning in ends of brackets or erecting stand ,32 mm waste coupling and waste pipe of 75 mm long complete all as specified & directed
111S & F in repairpolymer white (polypropylene Delrin and ABS) low level flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, flush pipe, brass screws, handle etc complete having BIS description mark with IS: 7231 with and including 32 mm bore PVC flush pipe of suitable length complete all as specified and directed.
112S&F 600mmx450mm bevelled edge mirror of selected quality glass 4 mm thick, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
113S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to wall complete all as specified and directed.
114S & F of 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to wall/floor complete all as specified and directed.
115S & F of 75 mm dia PVC (SWR) multi floor trap with grating including jointing with solvent cementt complete all as specified and directed.
116Providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) frame work for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws etc. complete all as specified and directed.
117S&F anodised aluminium powder coated (not less than 50 micron) designer grill of 5-6mm dia of mesh size 50x50mm centre to centre with 25mm flat as per sample kept in GEs office including aluminium beading, complete all as specified & directed.
118Preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b)Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm. (d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding materialwithblown type bitumen of grade 85/25 heating to aworking temperature of 180° C and applied @ 1.2 Kg/Sqm. (f) Applying a coat of bitumious based aluminium
119Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface of roof tiles/concrete padding etc including grubbing up of tree roots, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b)Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm. (d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding materialwithblown type bitumen of grade 85/25 heating to aworking temperature of 180° C and applied @ 1.2 Kg/Sqm. (f) Applying a coat of bitumious based aluminium
120Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed.
121Taking down carefully existing sub main wiring complete of any size and capacity complete all as specified and directed.
122Taking down carefully unserviceable main switches, DBs including MCBs etc. complete of any size and capacity complete all as specified and directed.
123M&L for point wiring one lightl/bell/fan/Exhaust fan point controlled by one way switch(concealed type) complete with multistranded copper conductor flame retardant low smoke (FRLS)1.5 Sqmm size PVC insulated unsheathed cable 1100 volts grade drawn through with and incl medium grade duty concealed PVC conduit ISI marked not less than 20mm dia including conduit fittings and accessories such as socket,elbow,junction box, bell mouth,bend, reducer etc complete incl cutting chases inexisting walls of any description built in cement mortar and making good the disturbed surfaces in cement mortar (1:4)and finishing the surfaces to match with existing surfaces and finish with using sunken type pressed steel terminal boxes of required sizes of not less than 1.6 mm thick factory made and factory painted with top cover of 3 mm thick plastic laminated sheet fixed with brass screws washers with all accessories including single core multi stranded copper conductor1.5 Sqmm size PVC insulated unsheathed cablegreen in colouras earth wire to common earth andconnected to earth dolly drawn in same conduit complete all as specified .NOTE :-Wire/Cablecolour coding Shall be maintained properly as per IE rule.
124All as per item No 123 but for one 3/5 pin socketoutlet 5 Amps on the same board with other switches.
125All as per item No 123 but for one 3/5 pin 5 Amp socket outleton independent board.
126All as per item No 123 above here in before but for Geyser/AC with 2.5 Sqmm (nominal area) cable PVC insulated but unsheathed for the 15 Amp 3/5 pin socket power point including 1.5 Sqmm copper conductor green in colour for earth continuity on independent boardcomplete all as specified and directed.
127Supply and fixing sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor cable of size 4.00 sqmm LT, 1100 V grade, drown through and incl adequate sizesPVC non metallic conduit of 25mm dia with accessories and fittings and one run of 2.50 sqmm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length, cable required for connection to DBs shall deemed to be incl and shall not be measured separately.Earth wire shall run inside the conduit pipe. (Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate).
128Supply and fixing sub main wiring (Concealed) with two runs of single core PVC insulated and unsheathed multistranded, copper conductor cable of size 6.00 sqmm LT, 1100 V grade, drown through and incl adequate sizesPVC non metallic conduit of 20mm dia with accessories and fittings and one run of 4.00 sqmm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length, cable required for connection to DBs shall deemed to be incl and shall not be measured separately.Earth wire shall run inside the conduit pipe. (Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate).
129S&F switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed.
130S&F socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type complete all as specified and directed.
131S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.
132S&F Ceiling rose three teminal /PVC/ polycarbonate,insulated body complete all as specified and directed.
133S&F electronic fan regulator, 2 module, 100 watt, (5 stepped type), 240 Volt for 1200/1400 sweep AC ceiling fan complete all as specified and directed.
134S&F Tube light fitting integrated type suitable for LED 20W (4 feet) indoor, decorative aluminium extruded T5 LED batten complete with housing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified & directed.
135S&F Tube light fitting integrated type suitable for LED 10W (4 feet) indoor, decorative aluminium extruded T5 LED batten complete with housing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified & directed.
136S&F rectangle LED high bay with excellent heat sink alongwith IP66 protection integral light recess Mounted under canopy luminaire with decorative reflector high bay luminaire suitable for 30 W including all fittings such as coupler, Refractor, etc complete all as specified & directed. Note : The rate is inclusive of fixing of lights at any heights, for which the contractor should provide the materials for fixing purpose.
137Supply and fixing factory made epoxy powder coated distribution board, VTPN, 8 ways with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 200 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable forONE FP-MCCB 160-250 Amp as incomer and SPN MCB outgoing, including taking down old unserviceable distribution board,complete all as specified & directed .
138Supply and fixing factory made epoxy powder coated distribution board, SPN, 12 ways (SPN MCB DB) with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable forONE SPN MCB DBincomer andMCB outgoing, including taking down old unserviceable distribution board,complete all as specified & directed ..
139Supply and fixing factory made epoxy powder coated distribution board, SPN, 8 ways with metal door double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 200 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for one SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
140Supply and fixing factory made epoxy powder coated distribution board, SPN, 4 ways (SPN MCB DB) with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 200 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable forONE SPN MCB DBincomer andMCB outgoing, including taking down old unserviceable distribution board,complete all as specified & directed ..
141Supply and fixing 240V, 10 KA "B" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing andcommissioning complete all as specified & directed.
142Supply and fixing 240V, 10 KA "B" curve miniature circuit breaker (MCB) of SPNand current carrying capacity 40 to 63 AMP, in the MCB DB Complete with connection testing andcommissioning complete all as specified & directed.
143S&F in replacement of MCCB 100 Amps four pole 415 volts thermal magnetic release ICU=100% ICS having breaking capacity 16 KA including connection terminal strip complete all as specified & directed.Make: Legrand/Schneider/ Simens
144S&F MCB TPN415 Volt 10 KA63 Amp "B" series conforming to IScomplete all as specified & directed.
145M&L forsub main wiring with 2 Single core PVC insulated unsheathed FRLScable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sqmm (nominal area) drawing in and including 25 mm dia or higher medium dutyPVC concealed conduit and conduit accessories and fittings. including one single core green colour PVC Insulated unsheathed FRLS cable copper conductor multistranded of size 6.0 Sq mm as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
146Supply & fixing metallic exhaust fan, 300mm (12") sweep, single phase, 230 volts, 50 Hz AC, 1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings, complete with louvers and shutters,connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cableincluding cutting holes in existing brick walls for making opening for fixing of exhaust fan of 300mm sweep including grounting bolts/nuts and making good disturbed surface of walls using cement sand mortar 1:4, complete all as specified & directed.
147Supply & fixing Air circulator fans, 450mmsweep, single phase,oscillating 230 volts, 50 Hz AC, 1400 RPM, energy saving, heavy duty suitable for wall mounting ,connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cablecomplete all as specified & directed.
148S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete complete all as specified and directed.
149S&F LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete complete all as specified and directed.
150S&F SPN enclouser with two pin and earth plug and socket complete with one single pole MCB 32 Amps, 240volts complete all as specified and directed.
151M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interior dimensions in PCC 1:2:4 type B-1 RCCcover with GI frame, charcoal and common salt 15cm in layers all round the earth plate, 15mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified as per electric plate No 3 of SSR 2009 including testing after completion complete all as specified and directed.
152S&L XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volt grade cross sectional area 16 Sqmm and 4core complete all as specified and directed.
153Taking down carefully ceiling fans from any height of any sweep/ make /model after disconnecting electric connections, servicing, overhauling, greasing etc, preparation of old surfaces of ceiling fans and blades by scraping out old existing paint with the help of emery paper/ wire brush, filling the cavities and painting with two coats of white synthetic enamelled paint over a coat of red oxide zinc chrome primer with the help of spray machine including greasing, re-writing MES SL No with black paint in capital lettersand replacement of defective components/ accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance, complete all as specified & directed.
154Supplying, installing and commissioning of LT panel board (factory made), outdoor, type of suitable size made out of 2.00mm thick CRCA sheet fixed with MS angle iron of size 40x40x6mm mounted on PCC floor, having two doors on both sides with locking arrangement and painting all steel surface internally and externally with two coats of synthetic enamel paint overa coat of red oxide zinc chrome primer suitable for 440 volt 3 phase 4 wire system enclosed with aluminium bus bar with making all electric connection with existing system including taking out old unserviceable panel and comprising of the following :-(a) Incoming(i)MCCB 400 amps, 415volt, 35 KA,4pole – 01No. (b) Outgoing(i) MCCB 200 amps, 415volt, 25 KA, 3 pole- 02 Nos. (ii)MCCB 160 amps , 415volt,25 KA, 3 pole – 1 No. (c)Digital voltmetre 0-500V – 01 No.(e)Indicator lamp assembly –01 Set(f)Timer switch single phase 63 amp - 01 No. (g)PCC 1:2:4 type B1 using 20mm graded aggraegate as in foundation for fixing of panel.
155Cutting holes in existing brick walls for making opening for fixing of exhaust fan of 250 mm sweep including grounting bolts/nuts and making good disturbed surface of walls using cement sand mortar 1:4, complete all as specified & directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail