Tender For Electrification Of Anganavadi 165-General Electrical Work.; 1 Electrification 2 90.2.1.1:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Single Control Light Point With 6A, Plate Ceiling Rose - Short Point 3 90.2.1.3:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Single Control Light Point Without Ceiling Rose - Short Point 4 90.2.1.4:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Single Control Ceiling Fan Point With 6 A, 3 Plate Ceiling Rose & With Socket Size Stepped Electronic Regulator. - Short Point 5 90.3.20.3:Supply & Installation Of Light Fittings On Tw Round Block Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thicknesscomplete With All Accessories Andlamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16 / 0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200 Mm 1X20w Led Lamp With Box Type Fixture 6 90.2.1.6:Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And DbS Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) .Combined Plug Point With 6 A, 5 Pin Plug Socket Controlled By 6 A, Switch In The Same Switch Board As That Of Light Points 7 Od169582 / 2023-2024:Supply &Amp; Fixing Angle / Straight Brass Lined Skrit Type Bakelite Batten Holder With 200Mm Polished Alu. Shade, 9W Led Lamp &Amp; Giving Connection As Required. 8 90.4.1:Supply And Installation Of Suitable Size Ms Rod Type Fan Clamp In The Rcc Slab As Per Is 732 As Required. 9 90.4.5.4:Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length ( Up To 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required.1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0 ( Cub Meter / Minute / Watt ) , Air Delivery Minimum 210 ( Cubic Meter / Minute ) , Copper Winding Suitable For 230V / 240V Single Phase Ac Supply 10 1.17.12:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 2.5 Sq. Mm 11 1.17.21:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 4 Sq. Mm 12 90.6.10.1:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm 13 90.6.10.2:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required25 Mm 14 2.3.2:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator8 Way, Double Door 15 2.10.1:Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 16 2.12.1:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 17 2.14.1:Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 Volts, Residualcurrent Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.25 Amps 18 1.24.3:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch 19 1.24.5:Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet 20 1.27.2:Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module ( 100Mmx75mm ) 21 Od169490 / 2023-2024:Earthing With 40 Mm Dia. Medium Class Gi Earth Pipe 2 Mtr. Long, Providing 12Mm Dia. Drilled Holes Minimum 20 Nos Along The Entire Length In Alternate Arrangement , Providing 40X25 Mm Gi Reducer At Top, Test Joint Using 2 Nos , 25X3 Mm Gi Strip Minimum Size 25Cm Suitably Shaped & Tightly Clamped To The Pipe Using 25X6 Mm Steel Bolt & Nut, Washer, Providing 2 Nos 6 Mm Dia. Drilled Holes For Clamping & Bolting Earth Lead , Making Masonary Chamber With Cover Plate Having Locking Arrangement Etc. ( Charcoal & Salt As Required Shall Be Filled At 30 Cm Dia .Around The Earth Electrode ) 22 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) 23 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm ( 10 Swg ) 24 Od169492 / 2023-2024:Supply & Installation Of Dust And Vermin Proof, 1 Phase Syntex Meter Board ( Gs-Mb-3425 Single Compartment ) And To Fix Kseb Meters, Fuse Units Etc As Required Including Fixing It On Wall, Making Good The Damages Colour Washing Etc. As Required 25 Od169493 / 2023-2024:Supply & Providing 32A Hrc Fuse Base Withhrc Fuse Link. 26 Od169494 / 2023-2024:Supply & Providing 32A , 2 Way Nl On Existing Meter Box

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Dec-2023 DATE EXTENSION Date 07-12-2023

Key Value

Document Fees
INR 335 /-
EMD
INR 1184.0 /-
Tender Value
INR 47356.0 /-

BOQ Items

Work Name:GENERAL-SO238/24- Pattanakkad GP-ELECTRIFICATION OF ANGANAVADI 165-General Electrical Work
Sl. No. Item Description
1Electrification
290.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
390.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
490.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
590.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thicknesscomplete with all accessories andlamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
690.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
7OD169582/2023-2024:Supply & fixing angle/ straight brass lined skrit type bakelite batten holder with 200mm polished Alu. shade,9w LED lamp & giving connection as required.
890.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
990.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
101.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
111.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1290.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
1390.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
142.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
152.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
162.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
172.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
181.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
191.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
201.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
21OD169490/2023-2024:Earthing with 40 mm dia. medium class GI earth pipe 2 Mtr. long, providing 12mm dia. drilled holes minimum 20 nos along the entire length in alternate arrangement ,providing 40x25 mm GI reducer at top, test joint using 2 nos ,25x3 mm GI strip minimum size 25CM suitably shaped & tightly clamped to the pipe using 25x6 mm steel bolt & nut,washer,providing 2 nos 6 mm dia. drilled holes for clamping & bolting earth lead ,making masonary chamber with cover plate having locking arrangement etc. (charcoal & salt as required shall be filled at 30 CM dia .around the earth electrode)
2290.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
2390.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
24OD169492/2023-2024:Supply & installation of dust and vermin proof, 1 Phase Syntex Meter Board(GS-MB-3425 Single Compartment) and to fix KSEB meters, fuse units etc as required including fixing it on wall, making good the damages colour washing etc. as required
25OD169493/2023-2024:Supply & providing 32A HRC fuse base withHRC fuse link.
26OD169494/2023-2024:Supply & providing 32A ,2 way NL on existing meter box