Military Engineer Services-MES has published Tender For Additional/Alternator To Building No P-163, Provision Of Drainage System In Aps And Near Key Pers Qtrs At Chandimandir Mil Station.. Submission Date for this Tender is 23-12-2023. Building Work Tenders in chandimandir Haryana. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 09-Dec-2023 | Revised Page | Other | 16-12-2023 |
2 | 16-Dec-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-12-2023 |
Sl. No. | Item Description |
1 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
2 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed. |
3 | IInd class hard wood (Hollock) bull nosed plain fillet square or rectangular in section clean sawn screwed with scews of sectional area exc 13 Sqcm but not exc 25 Sqcm, complete all as specified and directed. |
4 | Decorative laminates type I,1.5mm thick of surface finish, colour and pattern as approved , fixed with approved adhesive as per manufacturer instructions complete all as specified and directed. |
5 | 6mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified and directed. |
6 | Providing & fixing hangers of 6 mm dia. G.I. (upto 1200mm length), adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat of 40 x 3 mm size, 60mm long and expansion hold fasteners of 12.5mm dia, 40mm long with and including Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centrewith Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre with and including 10mm thick plaster of paris ceiling (Gypsum anhydrous) to round and any sunk and raised mouldingsurface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire meshcomplete all as specified and directed. |
7 | Providing wooden laminated flooring with bruce locking system having surface abrasion class AC-3 and density 920 Kg per Cum, of size 1215mm x 194mm x 8mm thick having fire rating class B1, complete all as specified and directed. |
8 | Solid 14mm thick wood polymer composite louvers wall paneling (size 192mm x 2900mm x 14mm) fixed to walls with necessary clip, screw / adhesive complete all as specified and directed. NOTE : The wall paneling has to be in conformity with the existing wall paneling at site. Bidders ae requestd to visit the site before quoting their bid. |
9 | 2mm thik PVC sheet fillet/ angle / beading of width 35mm for making frame for wall paneling inclusive of fixing on to wall , complete all as specified and directed at site. |
10 | Demolition of plain cement concretein ground floor and paving n.exc 15cm thickness below or above ground level complete all as specified and directed. |
11 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. |
12 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified. |
13 | Removal excavated soil to a distance not exceeding 50 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point complete all as specified & directed. |
14 | Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed. |
15 | Brick work with sub class ‘B’ bricksold size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed. |
16 | Brick work with sub class ‘B’ bricksold size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed. |
17 | 15mm thick rendering in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed |
18 | Supply only Integral waterproofing compound, all as specified. |
19 | Reinforced concrete pipes, 450mm dia, class NP3, laid and jointed complete with collars, jointed with cemet mortar, laid in trenches and tested including fittings of same grade complete all as specified and directed. |
20 | Reinforced concrete pipes, 150mm dia, class NP2, laid and jointed complete with collars, jointed with cemet mortar, laid in trenches and tested including fittings of same grade complete all as specified and directed. |
21 | Plain Cement Concrete 1:3:6 type C-2, (40 mm graded stone aggs) as insurface channels and drains, complete all as specified. |
22 | Plain Cement Concrete 1:2:4 type B-1, (20 mm graded stone aggs) as in coping complete all as specified and directed. |
23 | Cutting chases in brick walls,pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting n.exceeding 20cm girthcomplete all as speicified and directed. |
24 | Factory made RCC M-35 pre cast man hole covers(Medium duty), of size 450mm x 900mm x 75mm with plain faces, includingMS frame, set in position complete all as specified. |
25 | All as per serial itemNo 25 hereinbefore but size 600mm x 1200mm x 75mm thick |
26 | PVC(SWR)pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls or laid in floor, fixed as in repair complete all as specified and directed. |
27 | Pre-cast reinforced cement concrete type B-1, 1:2:4 using (20 mm graded crushed stone aggregate) as in manhole cover slabs etc set in cement mortar 1:4,complete all as specified and directed. |
28 | Mild steel high strength deformed TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bendingspirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed. |
29 | Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socketor power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete all as specified and directed. |
30 | Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. |
31 | All as per serial item 31 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed |
32 | All as per serial item 31 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed |
33 | All as per serial item 31 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
34 | Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. |
35 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. |
36 | Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose combined two module (ISI marked), complete all as specified & directed. |
37 | Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. |
38 | Modular switch type bell push, single pole, 230 volt one module,(ISI marked) complete all as specified and directed. |
39 | Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. |
40 | Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. |
41 | Lamp holder, PVC/Polycarbonate type with back plate angular type fixed on wall suitable for batten fitting ,complete all as specified and directed. |
42 | Electric Bell, ding dong, AC, 230 volts, single pole all as specified and directed by Engineer-in-charge. |
43 | MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed |
44 | Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 160Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . |
45 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
46 | Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 20 Amp 415 volt complete all as specifed and directed |
47 | MCB, SPN , 240 volt,40 to 63Amps, 10 KA , "C" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
48 | MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , "C" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
49 | Slim LED lights fitting, 4 feet,1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
50 | Round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
51 | LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
52 | Beuhome wall light matte nickel for engagement light with contemporary sleek design antique surface mounte classic wall light B-22 base complete all as specified and directed. |
53 | Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. |
54 | Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note: (i)For the purpose of measurement, 2 single core of 6 sqmm and one single core earth cable of 6 sqmm cableshall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth |
55 | Supply and fixing sub main wiring with Four singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i)For the purpose of measurement, 4 single core of 10 sqmm and one single core earth cable of 10 sqmm cableshall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail