Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantaling & Demolishing |
| 2 | Demolishing/ Dismantling Existing Auditorium Block (G+2)including digging of Foundation and demolishion of Super Structure including leveling the surface carefully as described in below, taking away all the salvageable materials, clearing and carting away the debris / unusable materials from the work spot including barricading, defastening, cutting, handling, stacking, etc., all as directed including all labour, equipment, tools tackles, scaffolding, Protection work,transport, safety ladders, safety belts, fuel etc. complete. Note:- 1. The tenderer shall indicate the salvage value of useful material (except wooden door- windows frames & shutter & all Alumninium work like partition, windows, doors etc) taken out from the building after adjusting the delmolishing cost. The net credit amount payable to the HansRaj College for the demolition of the building shall be calculated by deductingdemolition cost ofincluding scaffolding, transportation of serviceable and unserviceable material. Rate is including the cost of Unserviceable material and debris etc. to be disposed offto Contractor\"s own dump site, out side of Municipal limits of Delhi, cleaning of site after removal of Debries, malwa etc. entire to the satisfaction of EIC. 2. While dismantling vendor should take all safety mearsure bykeepingsand bagsand MS Jalli above the floor so that the dismantling work effect does not harm our existing under floor Area (i.e. Ground floor) &Adjoining Existing buildings of Block A & playground boundary wall. 3. Covered Area of building to be demolished to be measured ( no Projection will be measure). The contractor should visit the site before quoting this item. The Job include following below mention worksin Auditorium Block upto First floor roofincluding mezzanin of (inclusive). 4. Before actually taking up the demolishion of Building the contractor shall ensure disconnection of Electrical power supply to building, disconnection of water supply and sanitary connection to the building at their own cost & make temporary arregement so that college working should not distrub. |
| 3 | The Job-A include following : a.Auditorium Hall with stage, Projected balcony, Projector room, Greens Rooms, Toilets,Parapet walls , MS Grills & Terraceing.b. Auditorium R.C.C. slabs, Beams, column, Lintel, R.C.C.Working plateform , Masonary walls & Chajjas at Ground floor, First Floor & Terrace level.d. Bricks walls with Wooden door,window frame & shutter with window grills .e. Auditorium flooring including PCC & existing Foundation. f. Stage flooring including PCC& filled up materIal with existing Foundation.g. Aluminium doors & partitionh. Mazzanine / Balcony with railing.i. PVC water tank including all piping workj. Plumbing & saintary works of Toilet including fitting & fixture includingWall tile work.k.Structrual steel work with Puff panel of cabinl. Electrical fitting, Fixture, panels, Cables, socket-switch,DB, earth pit, etc & all others.m. M.S. & Steel Railing n.Wall Panelling of Auditorium Hall & Stage.o.Existing Lighting System of Auditorium Hall & Stagep. Air-Conditioning Ducting with indoor & outdoor units with stand & copper pipring, electrical, drain piping , etc complete with all respect (5 Nos. Unit of 11 Tonnes each)q.False Ceiling ofHall , Stage of Auditoriumof Ground Floor, r. Computer Labs of First Floor and Seminar hall of Second floor etc.s.Stage Wooden Flooring with C.C. & Auditorium hall Carpet.t. Auditorium Chairs(342 Nos. )u. Stage Curtains, Frill, curtain control system and Stage Wings with fixing arrgenjment.v.M.S. Bar forLightingof halls & stagew.Structrual steel work & M.S. jali from terrace parapet wall & window Grills.x.Electrical fitting & Fixture, conduit, wiring of Auditorium hall, Green room, all wash rooms, computer labs, seminar hall etc.Note:- Only Covered Area is to be measured for this item |
| 4 | s. Toilets fittings, Traps, fixture, plumbing pipe & Saintary pipes bend, G.I. & C.I/pvc/r.c.c pipe etc. of all wash rooms of Auditorium Block. t. Reomoving Exisiting terrace water proofing including Mud Phaska, Terrace Brick Tile, Gola, Terrace PCC, CC plate form, Khurra, RWP, Spouts, brick bats, parapet brick wall with coping and cleaning the existing roof top surface clean.The assessed salvage value of useful materials to be taken from the dismantle area ofAuditorium Block building.Note:- - Wooden doors & windowsFrames & Alumnium work from Ground Floor, First Floor & Second Floor of Auditorium Block should be taken out under serivceable condtition for reuseing& refixing to other college area as per direction of EIC. (Fixing charges including in item with required repair, no extra payment will pay)-Vendor can visit the site before quoting this item. - No extra payment will be made for this protection work & scaffolding /prop provided at adjustant area of Auditorium during the period of demolishing & reconstruction.Note:- The amount of this item shall be recoverable from contractor 1st Running Bill and shall be Deducted from total cost of the work. |
| 5 | Demolishing/Dismantling Existing porta cabin (G+1) Near Science Block (Plinth area 88.0 sqm) with its M.S. Staircase including digging of Foundation and demolishion of Super Structure including leveling the surface carefully as described in below, taking away all the salvageable materials, clearing and carting away the debris / unusable materials from the work spot including barricading, defastening, cutting, handling, stacking, etc., all as directed including all labour, equipment, tools tackles, scaffolding, Protection work,transport, safety ladders, safety belts, fuel etc. complete. Note:- 1. The tenderer shall indicate the salvage value of useful material (includingdoors, windows, puff walls puff roof, Deck slab, m.s staircase etc) taken out from theporta cabin after adjusting the delmolishing cost. The net credit amount payable to the HansRaj College for the demolition of the porta cabin shall be calculated by deductingdemolition cost ofincluding scaffolding, transportation of serviceable and unserviceable material. Rate is including the cost of Unserviceable material and debris etc. to be disposed offto Contractor\"s own dump site, out side of Municipal limits of Delhi, cleaning of site after removal of Debries, malwa etc. entire to the satisfaction of EIC. 2. While dismantling vendor should take all safety mearsure so that the dismantling work effect does not harm ourAdjoining Existing buildings of Blocks & playground boundary walls. 3. Covered Area of building to be demolished to be measured (no Projection will be measure). The contractor should visit the site before quoting this item. The Job include following below mention worksin Duble storeied porta cabin Block upto First floor puff ssheet roofwith its M.S Staircase. 4. Before actually taking up the demolishion of Building the contractor shall ensure disconnection of Electrical power supply to building, disconnection of water supply and sanitary connection to the building at their own cost & make temporary arregement so that college working should not distrub. |
| 6 | The Job-B include following : - Double storied porta cabin (Near Science Block) including M.S.columns with it MS Staircase.-Existing Puff walls, puff sheet roofing, Alumnium Windows with grill & Aumnum doos.-False ceiling tile with grid.-Deck Sheet, Flooring, PCC, foundation.-Electrical Points.-Air-conditing piping with its electirial worksThe assessed salvage value of useful materials to be taken from the dismantle area of porta cabin (G+1).Note:- - Vendor can visit the site before quoting this item. - No extra payment will be made for this protection work & scaffolding /prop provided at adjustant area of during the period of demolishing & reconstruction.Note:- The amount of this item shall be recoverable from contractor 1st Running Bill and shall be Deducted from total cost of the work. |
| 7 | Demolishing cement concrete with Stone/ Brick bats manually/ by mechanical means including disposal of material within College campus lead as per direction of Engineer - in - charge. |
| 8 | (a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 9 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within College campus lead as per direction of Engineer - in- charge. Note:- - While demolishing work, vendor should take all safety mearsure bykeepingsand bags, horizontla and vertical M.S. props for supporting and M.S. Jali above the floor and cover doors, windows, Electrical Switch board & Smart board with ply board & Polysheet as per dirction of EIC so that the demolishing work effect does not harm our existing under floor & roof.- No extra payment will be made for this protection work. |
| 10 | Extra for cutting reinforcement bars manually / by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |
| 11 | Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. workincluding staking with in College campus. Note:-Quantity verified by college Engineer. |
| 12 | Demolishing brick work with plaster / wall tile / without plaster manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within College campus lead as per direction of Engineer-in-charge.(No Extra or separate payment will be paid of Plater & wall Tiles dismantling ). |
| 13 | (a) In cement mortar |
| 14 | Removing mortar from bricks and cleaning bricks including stacking within a lead of College campus (stacks of cleaned bricks shall be measured) : Note:-Quantity verified by college Engineer. |
| 15 | (a) From brick work in cement mortar |
| 16 | Removing doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within College campus lead : as per direction of Engineer-in-Charge. |
| 17 | (a) Of area 3 sq. metres and below |
| 18 | (b)Of area beyond 3 sq. metres |
| 19 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within College campus lead:as per direction of Engineer-in-Charge. |
| 20 | (a) Of area 3 sq. metres and below |
| 21 | (b) Of area beyond 3 sq. metres |
| 22 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including with or without dismembering and stacking within College campus lead. Note:-Quantity verified byEngineer in charge. |
| 23 | Dismantling tile work in floors, wall and roofs laid in cement mortar including stacking material within College campus lead. |
| 24 | (a) For thickness of tiles up to 40 mm |
| 25 | Dismantling existing Kota/Mosaic, Granite stone flooring laid in cement mortar of any thickness including stacking of serviceable material and disposal of unserviceable material within College campus lead. |
| 26 | Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within College campus lead. |
| 27 | Demolishing mud phaska in terracing and disposal of material within College campus lead. |
| 28 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within College campus lead of: |
| 29 | (a) G.S. / Asbestoe /PVC /FRP Sheet |
| 30 | Dismantling stone slab roofing over wooden karries or R.C.C. battens or M.S. structure (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within college campus lead. |
| 31 | Dismantling and stacking within college campus lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of : |
| 32 | (a) R.C.C. |
| 33 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within College campus lead.Note:-Quantity verified by college Engineer |
| 34 | Dismantling cement asbestos/PVC or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within College campus lead. |
| 35 | Dismantling C.I. / PVC or asbestos rain water pipe with fittings and clamps including stacking the material within College campus lead : |
| 36 | (a) Up to 150 mm dia pipe |
| 37 | Dismantling G.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within College campus lead as per direction of Engineer-in-charge : Note:-Quantity verified by college Engineer |
| 38 | (a) 15 mm to 40 mm nominal bore |
| 39 | (b) Above 40 mm nominal bore |
| 40 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within College campus lead as per direction of Engineer-in-charge: |
| 41 | (a) Up to 150 mm diameter |
| 42 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials College store and disposal of unserviceable materials within College campus as per direction of Engineer-in-Charge. |
| 43 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within College campus including lead as per direction of Engineer-in-Charge. |
| 44 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in within College campus including lead as per direction of Engineer-in-Charge. |
| 45 | Shiftingunder serviceable condition of existing DG (125KVA) with wire, cable & Silencerand their Electrical Panels by mechanical means (Hydraulic) / manual ) including disconnect & Reconnecting of wire (also making temporary arregement during the period of construction), cable and all connection complete in all respect and FixedDG set in running including the cost of RCC platform/foundation/padistal as per direction Engineer-in-charge. (During shifting contractor should make temporary arrengement of electricity for college, so that College working should not hamper).( Note:- Vendor can visit the site before quoting this item) |
| 46 | Removing, Shifting,Re-fxing/Re-joining& temporary arragement with testing of including working condition & staking in safe custody of existing Electrical Panels, Main & Sub Distribution Panel/Board including disconnecting& Reconnecting of wires, cable & standcomplete in all respectwith accessories like nuts, bolts or welded joints including Refixing with suitable structural members, dash fastener, cutting hole and chases in walls, floor, R.C.C. beam etc, and making good the same, including painting and fittings with one coat of primer and two coats ofenamel paint complete as reqd. (During shifting contractor should make temporary arrengement of electricity for college, so that College working should not hamper/distrub.) ( Note:- Vendor can visit the site before quoting this item) |
| 47 | Removing & Refixingwith testing ofExisting Fire Fighting system including all Equipments, Piping, motor, pump set, water tank,etc of Auditorium Block Area,Adjustant Play Ground area, Double storied Porta cabin near science block (near sub-station)under serviceable condition and testing. Re-fix it atPlay Ground Area & Proposed Second Floor Terrace Level with jointing the complete Fire Fighting system including pipeing, water Tank, pump set, Air Visuel & Hydrant etc.(as requiredload including) complete in all respect conforming to IS & NBO Code with accessories like tees, elbows, flanged joints, rubber insertion, nuts, bolts or welded joints including fixing the pipe with suitable flat iron strip clamps/ brackets, structural members, dash fastener, cutting hole and chases in walls, floor, R.C.C. slab etc, and making good the same, including painting pipes and fittings with one coat of primer and two coats of red enamel paint complete as reqd. ( Note:- Vendor can visit the site before quoting this item) |
| 48 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, all loads including all lifts involved. Note:- Malba quantity is equal to dismantled material/items. No factor will be calculated in MB) |
| 49 | Earth Work |
| 50 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means all areas including disposal of excavated earth of any depth, all lead and lift up to any depthdisposed earth to be levelled and neatly dressed as per directorion of EIC. |
| 51 | (a) All kinds of soil |
| 52 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, anydepth including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed by EIC of College . |
| 53 | (a)All kinds of soil |
| 54 | (a-1)Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. |
| 55 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 150 m and lift up to 2.0m. |
| 56 | Providing Pest Control and Anti-Termite Treatment by appointing a specialised agency as per the secifications mentioned by the bureau of indian standards and agencies specfications (whichever is higher), for general civil, plumbing/ drainage and timber/ carpentary works, gypsum related work, including a 10-Year Guarantee Bond under suitable undertaking on stamp paper etc., complete as directed.(Mode of measurement to be on carpet floor-area & Double height area to taken only one time .) |
| 57 | Filling local Available Excavated earth in proposed stage area, plinth area, etcas per specfication by manual meaning in layers no exceeding 20 cm in depth, consolidating each deposit layers by ramming and watering, lead up to 50m and lift upto 1.5m. |
| 58 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 59 | Supplying chemical emulsion in sealed containers including delivery as specified. |
| 60 | a) Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 61 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)for below mention work: |
| 62 | a) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: |
| 63 | a1) With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. |
| 64 | b) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. |
| 65 | b1) With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. |
| 66 | c)Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. |
| 67 | Concrete Work |
| 68 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work up to plinth level : |
| 69 | (a) 1:3:6 (1 Cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size from natural sources). |
| 70 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centring, shuttering and finishing : |
| 71 | (a) 1:2:4 (1 Cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 72 | Providing and laying of piecesof Autoclaved Aerated Concrete blocks in sunken portion as per direction Engineer-in-Charge. |
| 73 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). |
| 74 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 75 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand including finishing the top smooth |
| 76 | Reinforced Cement Concrete Work |
| 77 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :Cement Make:- ULRRATECH,JK,AMBUJA, BIRLA, ACC . |
| 78 | (a) 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). |
| 79 | Reinforced cement concrete work in walls (any thickness), slab & beam including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement : Cement Make:- ULTRATECH,JK,AMBUJA, BIRLA, ACC . |
| 80 | (a) 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). |
| 81 | Providing and laying in position machine batched / machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 350 kg/cum. Excess/less cement used as per design mix is not payable/recoverable separately) Note:- Batch plant will be approved by Architect. |
| 82 | All works up to plinth level. |
| 83 | (a-1)Concrete of M 25 grade with minimum cement content of 330 kg /cum |
| 84 | (b) All works up to floor V level. |
| 85 | (b-1)Concrete of M 25 grade with minimum cement content of 330 kg /cum |
| 86 | Centering and shuttering including strutting, propping etc. and removal of form forup to 9.0 metres. Height with water proof ply 12mm thick. |
| 87 | (a) Foundations, footings, bases of columns, etc. for mass concrete. |
| 88 | (b) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 89 | (c) Edges of slabs and breaks in floors and walls. |
| 90 | (c-1 )Under 20 cm wide |
| 91 | (d) Weather shade, Chajjas, corbels etc., including edges. |
| 92 | (e) Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12mm thick. |
| 93 | (f) Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12mm thick. |
| 94 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) |
| 95 | a) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). |
| 96 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Make:- Tata, Sail. |
| 97 | (a) Thermo-Mechanically Treated bars. |
| 98 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Make:- Tata, Sail. |
| 99 | (a) Thermo-Mechanically Treated bars. |
| 100 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand) includingwater proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 101 | Brick Work |
| 102 | Brick work withcommon burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 103 | (a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 104 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level including exposed brick work with making horizontal and vertical grooves 10 mm wide 12 mm deep all shapes and sizes in : |
| 105 | (a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 106 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 107 | (a) Cement mortar 1:4 (1 cement :4 coarse sand) |
| 108 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. |
| 109 | Providing and laying autoclaved aerated Concrete blocks masonry with 150mm to 300 mm thick with Grade 1 AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer in-Charge.(The payment of RCC band and reinforcement shall be made for separately). |
| 110 | Granite / Marble Work |
| 111 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills, facias, flooring and similar locations of required any size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,all type of moulding (full or half round) and polishing to edges to give high gloss finish etc. complete at all levels. Basic Price :- Rs.300/-Sqft. |
| 112 | (a) Granite of any colour, shade & of any size. (sample approved by Principal/ Architect) |
| 113 | Providing edge moulding (full round) to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 114 | (a) Granite work. |
| 115 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 116 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any sizeas approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. Make:- Kajeria, Somany, Asain, Orient. Basic Rate :- 65/Sqft. |
| 117 | Aluminium work |
| 118 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including all SS fittings Like sliding door bolt, Hinges, tower bolt, motich lock, handle & door stopper as per Direction Engineer-in-Charge. |
| 119 | (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 120 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 121 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : |
| 122 | (a) Rectangular or square. |
| 123 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 124 | (a) 2nd class teak wood |
| 125 | (a-1) 50x12 mm |
| 126 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality. Make:- Merino, Century, Greenlam. |
| 127 | (a) 1.5 mm thick. |
| 128 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 129 | (a) Float glass panes |
| 130 | (a-1) 4 mm thick glass pane .Make:- Modi. |
| 131 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including the cost of dash fastener/ Hold Fast(4 nos. on each side), necessary filling up the gaps at junctionsi.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket & silcone for gap between frame & wall area)etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling to be paid for separately) : Make: Jindal, handalco, Mahvir. |
| 132 | (a) For fixed portion |
| 133 | (a-1) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 134 | (b) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 135 | (b-1)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 136 | Supply and installation of aluminium powder coated threetrack sliding type windows With safety grills with the all necessary locking arrangement of size 1200mmx 1800mm x 80mm with 16 gauge with one fix glazed ventilatoras per Drawing inclosed as per CPWD specification in existing puff panel wall / cement board partition wall of porta cabin at Ground floor& First Floor faculty department Rooms after making opening in existing puff wallas per direction of EIC. The thickness ofglass of 5.5 mm fixed with EPDM rubber/ Neoprene Gasket. |
| 137 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 138 | a) Pre-laminated particle board with decorative lamination on both sides. |
| 139 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): Make:- Saint gobind, Modi. |
| 140 | (a) With float glass panes of 5.50 mm thickness |
| 141 | Providing and fixing Powder coated aluminium grill of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 142 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : |
| 143 | (a) 125x64x2.50 mm |
| 144 | (b) 100x60x2.50 mm |
| 145 | (c) 75x50x2.50 mm |
| 146 | Providing and fixing ISI marked aluminium/S.S. butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 147 | (a) 100x63x3.2 mm |
| 148 | (b) 75x45x3.2 mm |
| 149 | Providing and fixing S.S. sliding door bolts ISI marked with nuts and screws etc. complete : |
| 150 | (a) 300x16 mm |
| 151 | Providing and fixing S.S. tower bolts ISI marked with necessary screws etc. complete : |
| 152 | (a) 300x10 mm |
| 153 | (b) 250x10 mm |
| 154 | (c) 200x10 mm |
| 155 | (d) 150x10 mm |
| 156 | (e) 100x10 mm |
| 157 | Providing and fixing S.S. handles ISI marked with necessary screws etc. complete : |
| 158 | (a) 125 mm |
| 159 | (b) 100 mm |
| 160 | (c) 75 mm |
| 161 | Providing and fixing S.S. hanging floor door stopper ISI marked with necessary screws etc. complete. |
| 162 | (a) Twin rubber stopper |
| 163 | Providing and fixing S.S. casement stays ISI marked with necessary screws etc. complete. |
| 164 | Steel Work |
| 165 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete. |
| 166 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 167 | (a) In gratings, frames, guard bar, ladder, railings, Grills, brackets, gates and similar works. Make:- Jindal, Tata. |
| 168 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (for payment purpose only weight of stainless steel members shall be considered including fixing accessories such as nuts, bolts, fasteners etc.) |
| 169 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40x40x5 mm, joints mitred and welded by angle iron 40x40x5 mm or 35x5mm / 40x5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener/ Hold Fast (4 nos. on each side), including fixing of necessary butt hinges and screws, dash fastener , Hold Fast and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 170 | Providing and fixing SS Railing ( 304 grade)of Height 1.0 M as per design approved by Principal/Architectwith 12mm clear Toughened glass with MTG fixing with Aluminium all complete as per the direction of Engineer-In-charge in the both side cantiliver Balcony / corridor of Auditorium 1st First Floor. |
| 171 | Flooring Work |
| 172 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :(Size 22\"x22\") |
| 173 | (a) 25 mm thick. |
| 174 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 175 | Rubbing and polish Existing Kota stone flooring with grey cement slurry mixed with pigment to match the shade of the slab complete as per Direction Engineer-In- Charge. |
| 176 | Providing and laying full body vitrified floor tilesin different sizes (thickness to be specified by the manufacturer) with water absorption\"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. (Make -Somany/ Kajaria/ Asian/Orient). Basic Rate :- 75/-Sqft. |
| 177 | Providing and laying non- skid vitirified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(For Toilet Block) (Make -Somany/ Kajaria/ Asian/Orient). Basic Rate :- 75/-Sqft. |
| 178 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 179 | Providing and laying Tactile tile (for vision impaired persons as per standards) of size 300mmx300mmx15mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc.complete as per direction of Engineer-in-Charge. (Make -Somany/ Kajaria/ Asian/Orient) |
| 180 | Providing and laying Heavy Duty vitrified floor tiles (Stone Grade)Size of Tile 600x600 mm having thickness 16mm with 08mm thick joint ( with PVC Spacer) with water absorption\"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand)complete. including the cost of Grout of joint & spacer. (Make -Somany/ Pavit/ Kajaria/ Asian/Nitco) (The Basic Price Rs. 125/- sqft) |
| 181 | Roofing |
| 182 | Providing and fixing on wall facePVC rain water pipes conforming to IS : 13592 Type A including Tee, Band, coupler, Grating & jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. |
| 183 | (a) 110 mm |
| 184 | (a) 160 mm |
| 185 | Providing and fixing Metal Tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metalgrid of hot dipped galvanized steel sections (galvanized @ 120gsm/sqm, both side inclusive) consisting of main T\" runner withsuitably spaced joints to get required length and of size 24x38mm\" joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross \"T\" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main \"T\" at 600mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. |
| 186 | Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. |
| 187 | GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5mm thick with 8mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 188 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight Mineral false ceiling tiles of approved texturespintone/cosmos / Hexa or equivalent of size 595 x 595 mm in truehorizontal level suspended on inter locking metal grid of hot dippedgalvanised steel sections (galvanising @ 120 grams per sqm includingboth side) consisting of main \"T\" runner suitably spaced at joints to getrequired length and of size 24x38mm made from 0.33 mm thick made from 0.33 mm thick (minimum) sheet, spaced 1200mm centre to centre, and cross \"T\" of size 24x28mm made out of 0.33mm (Minimum) sheet, 1200mm long spaced between main\"T\" at 600mm centre to centre to form a grid of 1200x600mm and secondary cross \"T\" of length 600mm and size 24 x28mm made of 0.33mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600mm panel to from grid of size 600x600mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval. |
| 189 | Laying 15mm thick densified edges mineral false ceiling tiles of approved texture (Spintone / Cosmos/hexa) in the grid including, cutting/ making opening for services like diffusers, grills,light fittings, fixtures, smoke detectors etc. Whereever required, Main \"T\" runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200mm centre to centre along main \"T\" , bottom exposed with 24mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by engineer-in-charge. Note:- Only false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. Make: Armstrong, Gyptck, Anutone, |
| 190 | Providing & fixing openabletype Trap Doors in false ceiling in 19mm thick Laminated HDMR board with necessary wooden /M.S./S.S. frameworkincluding hinges, locking arrangements etc.complete finished with 1.0mm thk approved laminate both sideas per Direction Engineer - in -Charge. |
| 191 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c cost ofdisposal of mulba/ rubbish to the nearest municipal dumping ground. |
| 192 | (a) For door/ window/ clerestory window. |
| 193 | Finishing |
| 194 | 12 mm cement plaster of mix :of all height. |
| 195 | (a) 1:4 (1 cement: 4 fine sand) |
| 196 | 15 mm cement plasterof all height on rough side of single or half brick wall of mix : includingwater proofing material in cement plaster work in proportion recommended by the manufacturers of all height. |
| 197 | (a) 1:4 (1 cement: 4 fine sand) |
| 198 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement: 3 fine sand) :of all height |
| 199 | (a) Flush / Ruled/ Struck or weathered pointing. |
| 200 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade of all height. |
| 201 | (a)Old & New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 202 | Finishing walls with Acrylic Smooth exterior paint of required shade :of all height. |
| 203 | (a) Old & New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 204 | Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant of all height. |
| 205 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete of all height. |
| 206 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : of all height. |
| 207 | (a) One or more coats. |
| 208 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. |
| 209 | (a) The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) |
| 210 | French spirit polishing : |
| 211 | a) Two or more coats on new works including a coat of wood filler. |
| 212 | Sanitary Installations |
| 213 | Providingandfixingwhitevitreouschinapedestaltypeor wall hung watercloset (European type) with seat and lid,(sample Approved by college) 10 litre low level white vitreous china flushingcistern&C.P.flushbendwithfittings&C.I.brackets,40mm flushbend,overflowarrangementwithspecialsofstandardmakeand mosquitoproofcouplingofapprovedmunicipaldesigncomplete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Make:-Hindware, Cera, Jaquar, Somany. |
| 214 | (a) W.C. pan with ISI marked white solid plastic seat and lid. |
| 215 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap,(sample Approved by college) 10 litre low level white P.V.C. flushing cisternincluding flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.Make:-Hindware, Cera, Jaquar, Somany. |
| 216 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mmwithwhitePVCautomaticflushingcistern,(sample Approved by college) with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps(allinC.P.brass)withwastefittingasperIS:2556,C.I.trap withoutletgratingandothercouplingsinC.P.brassincludingpainting offittingsandcuttingandmakinggoodthewallsandfloorswherever required : Make:-Hindware , Cera, Jaquar, Somany. |
| 217 | (a) Single halfstall urinal with5litre P.V.C. automatic flushing cistern |
| 218 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 219 | S.S Grab Bar (Handrails) of 35mm Diamay be provided in the handicapped Toilet for the support required for the movement of Wheel chair at the height of 750 MM from finish floor including all accessories fittings required for fixing as per Handicpped Toilet as per Direction Engineer-In-Charge. |
| 220 | Providing and fixing wash basin above/ under counter or wall hung with C.I. brackets, 32 mm C.P. brass waste of standard pattern,including ,waste coupling, jalli, connection & painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back under counter/ above counter / without counter ( pedistal) Wash Basin size600x400 mmMake:-Hindware, Cera, Jaquar, Somany. |
| 221 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe including the cost of ss screw for fixing. |
| 222 | Providing and fixing S.S. Waste Coupling 32mm Size Full Thread completewith jalli for wash basinsinkapproved quality . Make:-Hindware, Cera, Jaquar, Somany. |
| 223 | Providing & Fixingfollowing toilet accessories complete including extension nipple & making hole in granite counter & r.c.c slab, & wall tile as per following detail :-Make:-Hindware, Cera, Jaquar, Somany, Kohlar. |
| 224 | (a) Concealed stopcock with long sleeve sliding cap(Basic rate Rs.700/-) |
| 225 | (b) Angular stop valve with wall flange ( Basic rate Rs. 750/-) |
| 226 | (c) 15 mm diameter small body bib cock wit extension nipple(Basic rate Rs. 500/-) |
| 227 | (d) High Flow Divertor body( 2 way inlet) with S.S. Face plate(Basic rate Rs.3500/-) |
| 228 | (e) Exposed part of HI flow Divertor ( 2 way inlet) Face plate (Basic rate Rs. 2500/-) |
| 229 | (f) Bottle Trap (Basic rate Rs. 650/-) |
| 230 | (g) Health Faucet / Jet (Basic rate Rs. 600/-) |
| 231 | (h) Towel Ring / cloth hager /clip |
| 232 | (i) Shower with arm casted (heavy) size :-150mm dia (Basic rate Rs.1500/-) |
| 233 | (j) CP Ext Pcs of required length as per site condition. |
| 234 | (k) Trap Jali - 5\" dia ( SS 304 grade) |
| 235 | (l) Toilet paper holder with flap (in S.S.) |
| 236 | (m) Hand dryer ( make :- Garnet) |
| 237 | (n) P/F CP brass swan neck wash basin mixer of 12\" height fixed to existing counter basin |
| 238 | Angle valve for basin mixer and geysor points of any size |
| 239 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 240 | (a) Flexible pipe - 40 mm dia |
| 241 | Providing and fixing mirror of superior glass (of approved quality) fixed on 6mm thk ply fixed on wall and of required shape and size with S.S. Stud & Bevel edge of approved make as per Direction Engineer-In-Charge.Make:- Saint Gobin, Modi. |
| 242 | (a) Rectangular shape |
| 243 | Toilet Cubical |
| 244 | T-Line Toilet cubicle with SS grade 304 Size of cubicles:-1100(W) approox X 1500(D) approox X 2100(H) approox. Thickness of Compact Laminate:- 12 mm, Door:- 610mm(W) x 1725 mm (H) Divider Height:- 1775mm Overall Height:- 1980mm (including bottom gap of 150mm) Accessories:- 1. SS Hinges with cover2. SS Coat hook3. SS Door Knob4. SS Privacy Thumb turn c/w occupancy indicator 5. SS Adjustable Foot-316 grade6. SS“U” Channel7. SS”F” channel (Only corner unit)8. SS Top Rail9. Rubber Lining for groove10. SS Screw 304 G & P PVC Wall plugs11. SS Shoe box leg 12 mm Grade 316Make: Merino,Greenlam. |
| 245 | Urinal Modesty Panel:- Size:- 450mm x 900mm including all Accessories:-design & color scheme will be approeved by college principal. Make: Merino, Greenlam. |
| 246 | \"Providing & fixing Ringfit / Pasting Type uPVC (Type-B) conventional system for Soil, Waste & Rain Water including cost of Coupler, Bend, Tee, Single Y, Vent Cowl, End cap, coolar, terminal guard,Clip, ClampM.S. Holder-bat clamps & testing of joints complete including the cost of cutting holes and making good the wall/RCC area , etc as per direction of Engineer in Charge. Make - Astral / Supreme / Prince / Prakash |
| 247 | (a) 75 mm dia |
| 248 | (a-1) Pipe |
| 249 | (b)110 mm dia |
| 250 | (b-1) Pipe |
| 251 | Water Supply |
| 252 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes cost ofjointing of pipes, cutting of holes in brick work/rcc area & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall Make : Supreme, Prakash, Polycab, Astral. |
| 253 | (a) 15 mm nominal outer dia .Pipes. |
| 254 | (b) 20 mm nominal outer dia .Pipes. |
| 255 | (c) 25 mm nominal outer dia .Pipes. |
| 256 | (d) 32 mm nominal outer dia .Pipes. |
| 257 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases, cutting of holes in brick work/rcc areaand making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. -Make : Supreme, Prakash, Polycab , Astral . |
| 258 | (a) 15 mm nominal outer dia .Pipes. |
| 259 | (b) 20 mm nominal outer dia .Pipes. |
| 260 | (c) 25 mm nominal outer dia .Pipes. |
| 261 | (d) 32 mm nominal outer dia .Pipes. |
| 262 | Making connection of CPVC / G. I. distribution branch with CPVC / G. I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :Make : Supreme, Prakash, Polycab, Astral . |
| 263 | (a) 20 to 40 mm nominal bore |
| 264 | (b) 50 to 80 mm nominal bore |
| 265 | Cutting holes up to 30x30 cm in walls/RCC slab/RCC beams including making good the same: |
| 266 | (a) With common burnt clay F.P.S. (non modular) bricks. |
| 267 | Cutting holes up to 15x15cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. |
| 268 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Make: Sintex, Supreme, Finolex |
| 269 | DRAINAGE |
| 270 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement completewith pre coast cover, frame & m.s.foot rests as perdesign : |
| 271 | a) Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 38 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 272 | b) Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 116 kg and weight of frame 100 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 273 | Extra for Depth for Manhiles: |
| 274 | a) Size 120x90 cmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 275 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
| 276 | For pipes 100 to 250mm diameter |
| 277 | For pipes 250 to 300 mm diameter |
| 278 | Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with pre-cast R.C.C. vertical grating complete as per standard design : |
| 279 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 280 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round all size pipes including bed concrete as per standard design: |
| 281 | Structure Repair |
| 282 | Chipping of existing unsound/weak concrete with plaster material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge Note:- - While Chipping vendor should take all safety mearsure bykeepingsand bags, propsand MS Gali above the floor and cover doors, windows, Electrical Switch board & Smart board so that the Chipping work effect does not harm our existing under floor & roof , if required. No extra payment will be made for this protection work. |
| 283 | (a) Above 50mm to 75mm thickness (Beams Bottom & Top surface) |
| 284 | (b) up to 50mm thickness (Exiting roof slab & beams side) |
| 285 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 286 | Bars up to 12 mm diameter |
| 287 | Bars above 12 mm diameter |
| 288 | Supplying and applying anti corrosive treatment with two component Zinc rich epoxy primer after cleaning the reinforcement including thecost of removing of rust from barsincluding the cost of anti corosive paint as per technical specification on exposed reinforcement as well as newly provided reinforcement and mesh. The rate shall include all material, labour, plant and machinery, tools and tackles, preparation of surface as per technical specification, for all leads and lifts- complete.Approved Brands: BASF / Fosroc /Huntsman / Sika Cleaning reinforcement of total rust by tapping and using mechanical wire brush or any other suitable way to give it a totally rust free finished steel surface (Mode of measurement - chipping surface area with exposed reinforcement) |
| 289 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm up to 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In- Charge. |
| 290 | a) Up to and including 12mm dia. |
| 291 | Providing & fixing shear connectors of 12mm dia steel up to 150mm length with sika Anchor Fix -3+ / Mungo/ Fisher Fisv 390/ Hilti RE -500 Epoxy resin RCC members including power drilling, cleaning of holes, insertion of epoxy, placing shear connector in position to ensure the bond as per manufactire recommendation complete as per site requirment and direction of Engineer or Architect. |
| 292 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC by mixing high dispersion SBR latex like Master Emco SBR 2 of BASF with white cement in the ratio of 2:3, The mixing should be done to lump free consistency for the bond coat and the screed/mortar should be applied once the bond coat is tacky.Master Emco SBR2 of BASF or Nittobond SBR-2 (Latex) of Fosroc or Equivalent. |
| 293 | (a) Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make |
| 294 | Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. |
| 295 | Making of hole size of 152 mm diameter upto a depth of required depth withelectrical diamond corecuttingmachineinPCC / RCCbeams, slabs, floors etc. (1.0M c/c) wherever required at locations instructed by engineer-in-charge, taking out the cut core including all labours, tools and tackles complete including making hole in the slab / flooring to facilitate fixing of the frame of core cutting machine as per the site condition, marking the levels, makingand placing wooden templates etc. if required including removal of of anchor bolt after coring as per required. |
| 296 | Micro Concreting:Providing and laying ready to use non shrink. Cementious free flow micro concrete for the structural members e.g. columns, pillars, piers, beams slab Jacketting etc. of compressive strength >= 50 Mpa ( 28 days) according to ASTM C 109 of approved make and manufacture complete as per direction of Engineer- in - charge for replacing the carbonate part of concrete and repairingthe damaged surface of concete after fix the form work across the profile of damaged structural element or area. Pour the free flow non shrink Cementious free flow micro concrete mix in the form work. Cast-in-situ or any other suitable technique may be used to apply the concreteat all floor and all height including the cost of making holes in existing RCC slab @1.0mm c/c, if required, for pouring concrete in shuttering mould of jackett, centering, shuttering & including the cost ofsmooth surface finishing . Make: Renderock RG of Fosroc/ SikaRep Microcrete - 4 of Sika.Note:- Providing and erecting steel props (braced at centre and supported a continuous 2\"x3\"wooden runner, double height scaffolding system, resting on wedge and block minimum capacity 3 Ton) to support the structure provisionally during repair and jacketing etc. and maintaining them in position till required as directed by the Engineer-in-charge. ( no payment will be paid for props double height scaffolding system etc work). Make : Sikka, Dr. Fixitit, Fosroc as pproved by EIC/Architect) |
| 297 | (a) Micro Concreting Thick up to 100mm |
| 298 | Providing and laying of light weight foam concrete in sunken area of maximum density 800kg/cum including pumping of concrete to site of laying all lead & lift all height as per direction Engineer-in-Charge of approved mae:- |
| 299 | Providing and erecting steel props (braced at centre and supported a continuous 2\"x3\"wooden runner, resting on wedge and block minimum capacity 3 Ton) to support the existing structure provisionally during Retrofitting, repair & jacketing period/ duration etc. and maintaining them in position till required as directed by the Engineer-in-charge. |
| 300 | (a) upto 4.50 M height |
| 301 | (a) up to 9.0 M height |
| 302 | Centering, shuttering & scaffolding where ever required for structural strengthening &protection work with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, up toheight of 9.0 m,will be remain till the strengthening work completed) |
| 303 | (a) Suspended floors, roofs, landing, floor, beams and balconies (single Plan area of double height of Auditorium to be measured of any height ). |
| 304 | Supplying and fixing 4mm thick weld mesh of size 50mm x 25mm for floor/roof slab to be fixed firmly anchored to the concrete surface by means of \"L\" shaped mild steel shear key welded with existing reinforcement & concrete screed over the micro beams, slab, structural members, column & pier as reinforcement. The weld mesh shell be fixed as per drawing & Design. including the cost of materials, labour, tool & plants as approved by engineer-in-charge. |
| 305 | Supplying and fixing 4mm thick weld mesh of size 50mm x 25mm for floor/roof slab to be fixed firmly anchored to the concrete surface by means of \"L\" shaped mild steel shear key welded with existing reinforcement & concrete screed over the micro beams, slab, structural members, column & pier as reinforcement. The weld mesh shell be fixed as per drawing & Design. including the cost of materials, labour, tool & plants as approved by engineer-in-charge. |
| 306 | Steel reinforcement for R.C.C. work ready to use \"cut and bend\" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. (Make: Tisco, SAIL, Jindal, Tata) |
| 307 | (a) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 308 | Rebarring Connection SystemThe work includes following:(i) Making hole for rebar in concrete / masonry surface of required dia and depth as required at site by using HILTI or any other equivalent make drilling tools.(ii) The holes should be blown out using compressed, oil free air. Extension tubes and air nozzles directing the air to the hole walls should be used, if holes are deeper more than 250mm with special designed BOSCH or any other equivalent Blower. Deeper holes more than 250mm should as well be brushed by machine brushing using steel brushes and brush extensions(iii) Insert chemical compound HY150 / Hilti RE- 500, HY 200 / Hilti RE-500, Re-100, or equivalent with special designed guns.(iv) Placing of the rebars should be inserted into the hole with a slight rotary motion after injecting the rebarring chemicals.Rate shall include all charges for above operations including double height scaffolding system , packers and preparation of surface, cost of necessary chemical / foil as per manufactures specification and necessary tools and equipments including removal of debris from the site all complete as directed by Engineer-in-Charge.Make:- Hiliti, Bosch, Fischer. |
| 309 | a) 12 mm dia rebar with 14 mm dia 75mm deep hole |
| 310 | b) 16 mm dia rebar with 17.5 mm dia 1000mm deep hole |
| 311 | c) 20 mm dia rebar with 24 mm dia hole |
| 312 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand) includingwater proofing material in cement plaster work in proportion recommended by the manufacturers.(for Micro area) |
| 313 | 12 to 18mm cement plaster of Mix: |
| 314 | a) 1:1:2(1 cement:1 sand:2 fine sand) |
| 315 | Providing & supplying the one component, polymer midified cementitious Anti-corrosive primer ( having the techanical parameters mentioned in material specifcations) formulated t pe dual protection of a polymeric barrier and an integral corrosion-inhibting system, to the existing steel & additional steel provided before patching of damaged areas, using suitable tools and equipment inclusive of Material, Manpower and Equipment. BASF Master Emaco P 130/fosroc Nitoprime Zincrich / sika Rustoff 100 or other equivalent. |
| 316 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: Make:- Tata, Jindal. |
| 317 | Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately) including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : |
| 318 | a) Red sand stone slab |
| 319 | a1) 40 to 50 mm thick |
| 320 | Waterproofing |
| 321 | Providing and laying water proofing treatment on roofs of slabs by applying water proofing compound consisting of applying: a) after surface preparation, first layer of slurry of Dr. Fixit Fastflax @ 0.06 sqm / kg. b) laying second layer of Fibre glass cloth. Overlaps of joints of fibre cloth should not be less than 10 cm as per direction Engineer - In - Incharge. |
| 322 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. |
| 323 | d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : (NOTE:- only terrace floor area will be measured for this item) |
| 324 | With average thickness of 120mm and minimum thickness at khurra as 65 mm. |
| 325 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) |
| 326 | Electrical Works |
| 327 | ELECTRICAL & GENERAL ILLUMINATION SYSTEM |
| 328 | PointWiring |
| 329 | Point wiring rates are inclusive of 2.5 sq mm FRLS PVC insulated stranded copper conductor FRLS wires for submain circuit and 1.5 sq mm insulated looping and earth wire. All wire should be FRLS |
| 330 | (a) Wiring for light point /call bell point with 1.5 Sq.mm FRLS PVC insultated copper conductor multistrand wire in surface/recessed PVC conduit,with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor multistand copper wire etc. as required. Wire Make: -Havells ,KK kable, Polycab, Finolex. Conduit Make:- Supreme, Prakash, Setia, Switch. Make:- Anchor Roma, North West, Norsis. |
| 331 | Wiring for 16 amps power outlet points with 4 sq.mm FRLS PVC insulated stranded copper conductor wires in concealed/recessed P.V.C.conduit as directed including providing 16 amps flush type switch and 6 pin socket with cover plate 5 sided G.I. outlet boxes for switches and socket and earthing the third pin with 4.0sq mm PVC stranded copper wire complete as required (Only one outlet shall be connected on each circuit)Wire Wire Make: Havells ,K K kable, Polycab, Finolex.Conduit Make:- Supreme, Prakash, Setia. switch Make:- Anchor Roma, North West, Norsis. |
| 332 | Wiring for 5 amps light plug outlets with 1.5 sq.mm FRLS PVC insulated stranded copper conductor wires in P.V.C.Conduits in ceiling/walls/floor as directed including providing 6 amps flush type 5 pin socket and 6 amps switch with cover plate, 5 sided G.I boxes for housing switches, sockets and earthing complete as required. (for general areas) Wire Make: Havells, K K Kable, Polycab, Finolex. Conduit Make:- Supreme, Prakash, Setia. switch Make:- Anchor Roma, North West, Norsis. |
| 333 | Wiring for Ceiling fan points with 1.5 Sq.mm FRLS PVC insulated copper conductor wires in concealed P.V.C.conduits in ceiling / walls as directed including providing Hexagonal fan Box, and electronic fan regulator 5 A switch, 5 sided G.I. Boxes for housing the regulator, switch and earthing complete as required. Wire Make: Havells, K K Kable, Polycab, Finolex. |
| 334 | Wiring for exhaust Fan/ wall Fan points with 2.5 sq.mm FRLS PVC insulated stranded copper conductor wires in concealed P.V.C.conduits in False Ceiling/ Wall / Ceiling as directed including providing 6 amps flush type switches 6 amps 3 pin socket near exhaust fan/wall fan, 5 sided G.I. boxes for housing switches and 6 amps 3 pin socket outlet and earthing and complete as required. wire Make: Havells, K K Kable, Polycab, Finolex. Conduit Make:- Supreme, Prakash, Setia,Make:- Anchor Roma, North West, Norsis. |
| 335 | Loop Point Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FRLS PVC insultated copper conductor multistrand wire in surface/recessed PVC conduit,and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor multistand copper wire etc. as required.Wire Make: Havells ,K K kable, Polycab, Finolex. Conduit Make:- Supreme, Prakash, Setia.Make:- Anchor Roma, North West, Norsis. |
| 336 | Wiring for 16 amps power outlet points with 6 sq.mm PVC insulated stranded copper conductor wires for the first power outlet and 4 sq.mm PVC insulated stranded copper conductor wires for the second outlet, in concealed MS conduits in False Ceiling/ Walls/ Ceiling/ Floor ducts as directed including providing 16 amps flush type switch and 6 pin socket with cover plate, 5 sided G.I. outlet boxes for housing switches and socket, and earthing the third pin with 6.0sq.mm PVC insulated copper conductor wires complete as required (Two power outlets shall be connected on each circuit) Make: Havells, K K Kable, Polycab, Finolex .Conduit Make:- Supreme, Prakash, Setia.switch Make:- Anchor Roma, North West, Norsis. |
| 337 | Wiring for 5 amps light plug outlets with 2.5 sq.mm FRLS PVC insulated stranded copper conductor wires with earth wire inP.V.C.Conduits in ceiling/walls/floor as directed including providing 2nos. 6 amps flush type 5 pin socket and 1no. 6 amps switch with cover plate, 5 sided G.I boxes for housing switches, sockets and earthing complete as required.Make: Havells, K K Kable, Polycab, Finolex .Conduit Make:- Supreme, Prakash, Setia. Switch Make:- Anchor Roma, North West, Legrand. |
| 338 | Conduiting and wiring for Tele, Computer & T.V. system. |
| 339 | Providing and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Conduit Make:- Supreme, Prakash, Setia. |
| 340 | (a) 25 mm |
| 341 | (b) 32 mm |
| 342 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductorwire in surface/recessed PVC conduit as required as directed by EIC of College. Wire Make: Havells ,k k kable, Polycab, Finolex |
| 343 | a) 2 x 2.5 sq.mm + 1 x 2.5 sq. mm earth wire |
| 344 | b) 2 x 4 sq.mm + 1 x 4 sq.mm earth wire (for power) |
| 345 | Providing and fixing in position suitable 1.6 mm thick G.I. outlet box with 2 Nos RJ - 45 for Data/ voiceoutlet including crimplingwith all fixing accessories as required. |
| 346 | Supply and Laying including numbering / ferruling of wire (8 digit) and the continuity test for each cableofCat 6 - Telephone / Data cable in existing G. I. Channel / conduit. |
| 347 | Supply and fixing of 1.6 mm thick G.I Box along with RG 11 TV Co axial socket with Cover Plate for TV Outlets |
| 348 | Supply drawing connecting testing and commissioning of TV Coaxial cable RG 59 in existing conduit for CCTV System |
| 349 | Supply and fixing of 1.6 mm thick G.I Box with Hylum sheet over outlets as required. |
| 350 | Supplying and fixing of lighting fixtures |
| 351 | Supplying, installation testing & commissioning of following Lighting fixtures complete. (Make :- Philips, Bajaj, Usha, Wipro, Ankur, siska as per approved material list) |
| 352 | (a) Round Surface light/recesseLed Light 22 watts including all fixture as per approved material list |
| 353 | (b) 4\" long LED surface tube Light as per approved material list |
| 354 | (c) Ceiling Fan (1400 mm ) dia 1400 RPMBLDCwithstep Regulator switch as per approved material list |
| 355 | (d) Exhaust Fan (300 mm ) Heavy Dutywith G.I. Louvers as per approved material list |
| 356 | (e) Exhaust Fan (450 mm )Heavy Duty with G.I. Louvers as per approved material list |
| 357 | (f) Wall Fan (450 mm ) dia as per approved material list |
| 358 | (g) Extra over Item No. (c) for providing 900 mm hanging rod in place of 300 mm hanging rod as per approved material list |
| 359 | (h) Extra over for providing 900 mm hanging rod arrangement for Light Fixtures. as per approved material list |
| 360 | (i) Mirror Light 11W complete fixing and providing as per approved material list. |
| 361 | (j) 2\"x2\" square LED Light 20 watt (Conceal or surface mounted) as per approved material list |
| 362 | Earthing |
| 363 | Providing and fixing in position the following copper strips and wires including providing all fixing accessories and effecting proper connections |
| 364 | (a) Copper Flat 50 mm x5 mm |
| 365 | (b) GI Flat 50 mm x 5 mm |
| 366 | (c) GI Flat 25mm x 5 mm |
| 367 | (d) Copper Flat 25mm x 5 mm |
| 368 | (e) GI Wire 8 SWG |
| 369 | Providing, laying, testing and commissioning of 600 x 600 x 6.3 mm thick GI electrode, with 2 no. 50 X 5 mm GI strips from earth electrode to inspection chamber, 50 mm dia medium class GI pipe, CI funnel with 20 gauge GI wire mesh, masonry chamber 450 x 450 mm with 3 concrete base CI / Heavy duty chequered plate manhole cover with frame painted with bitumastic paint and packing with mixtures of charcoal and common salt around plate electrode including digging of pit upto permanent moisture level but not less than 3 meter. |
| 370 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 371 | Distribution boards |
| 372 | Light & Power Distribution Board |
| 373 | (a) Supply and installation of sheet metal enclosed double door 12 Way TPN DB, each phase consisting of 12 Nos. 10/20 AMP SP MCB’s and controlled by one number 63 Amps DP MCB. ELCB on each phase. Make:- Hager, Legrand,L& T |
| 374 | Cables, pipe & cable tray |
| 375 | Supplying and laying of the following sizes of 1100 Volts grade PVC insulated copper conductor wires in Suitable Size of MS conduit including and termination for DB Sub mainMake: Havells, K K kable, Polycab, Finolex. |
| 376 | (a) 3.5Core 185 Sqmm Cable. |
| 377 | (b) 4 x 10 + 2 x 6 sq. mmPVC insulated stranded copperconductor wires |
| 378 | (c) 4 x 16 mm + 2x 6 PVC insulated stranded copperconductor wires |
| 379 | (d) 4 x 25 + 2 x 6 sq. mm PVC insulated stranded copperconductor wires |
| 380 | Supply & installation of underfloor raceways of powder coated CRCA Mild Steel with cover of following sizes inclusive of cutting, chasing & refinish with cement plaster in PCC/IPS flooring |
| 381 | (a) 100 mm x 38 mm x 2 mm thick |
| 382 | (b) 50 mm x 38 mm x 2 mm thick |
| 383 | Supply & Installation under-floor junction boxes fabricated from 14 gauge CRCA Mild steel, duly epoxy painted / powder coated after 7 tank processes, with screwed recessedtop covers, screwed plates on four sides, of the following sizes, as per specifications. |
| 384 | (a) 200 mm x 200 mm x 40 mm |
| 385 | (b) 150 mm x 150 mm x 40 mm |
| 386 | Design manufacture , supply and fixing in position the cable trays of the following sizes for supporting 1.1 KV grade armoured/unarmoured aluminium /copper conductor cables. Fabricate the cable trays from perforated 1.6/2mm thick M.S. CRCA sheet duly galvanised with expansion coupler plates duly galvanised,with bolts, washer and nuts. Knock out holes for cable connections as per approved design. The tray should comply with the specification of NEC (National Electric Codes) and NEMA (National Electric Manufacturers Association). The steel should be as per IS:226 and galvanising as per IS :2629/BS 729/ASTM 123.The rate shall also include for supporting steel , fish plates , fixing accessories , nuts bolts, supporting down rods,dash fastener, cutting the RCC etc. complete as required. |
| 387 | (a) 150 mm wide x 40 mm x 2.0 mm thick |
| 388 | (b) 300 mm wide x 40 mm x 2.0 mm thick |
| 389 | Sub Distribution Boards |
| 390 | Sub Distribution Boards |
| 391 | Design, manufacture, supplying, assembling at site, installing, testing and commissioningand connecting it to colleg main panel/sub-station of the following cubical type, dead front, 2mm thick sheet steel enclosed, free standing indoor type extendible Sub-distribution Boards with vermin proof hinged lockable doors for each compartment provide bus bar interconnections for incoming and outgoing including feeders earthing and painting and as per specifications.Make:- Hanger, Legrand, L&TTheSub Distribution Board - 1 for Light & PowerSDB-1shall consists of : |
| 392 | INCOMER: Main Incomer 315 amps TPN MCCB (35 KA) terminals to receive3.5 x 185 sq. mm AYFY cable connection on one side and Bus bar connection on the other side. |
| 393 | BUSBARS: 400 amps 4 pole bus bar chamber of suitable length with Copper bus bars. All bus bars and interconnections shall be of suitable size copper strips current density of coppershall not be more than 1.6 Amps/ sq.mm provide 100% capacity for neutral bus bar. |
| 394 | INDICATING PANEL: 3 nos. phase indicating lamps each backed up with MCB and switch shall be provided for incomer. Provide Multi functional meter type Mach Smart 96 (96 mm x 96 mm) covering 25 electrical parameters for each incomer. |
| 395 | OUTGOING:2 No. 100 A 4P MCCB (35 kA) suitable to receive 4 x 35 sq mm AYFY Cable.2 No. 100 A TPN MCCB (35 kA) suitable to receive 4 x 20 sq mm AYFY Cable. 12 Nos. 40 A TPN MCB (10 kA) suitable to receive 4 x10 sq. mm YFY Cable. 2 Nos. 20 A TPN MCB (10 kA) suitable to receive 4 x 4 sq. mm YFY Cable. 3 Nos.32 A DP MCB (10 kA) suitable to receive 3x4 sq. mm YFY Cable |
| 396 | TheSubDistribution Board -1as described with complete specifications |
| 397 | VRV Air conditioning Works |
| 398 | Lecture Halls. |
| 399 | VRV outdoor Units |
| 400 | ITC of VRV Variable refrigerant Volume modular type outdoor units equipped with highly efficient inverter type compressor(s) , air coolled condenser with special precoated fins type heat exchanger and direct drive low noise propeller fan system suitable for heating / Cooling. Indoor and outdoor units complete as per quantity given below. Electrical equipments suitable 415V 50Hz power supply. Inclusive the cost of Stand. Make:- Daikin/ Mitsubishi Electric/Toshiba |
| 401 | (a) Outdoor Units. |
| 402 | (a-1 )44 HP Heat Pump Model |
| 403 | Installation and gas charging - first charge refrigerant (R-410A or equivalent) with lubricating oil. |
| 404 | ITC of Indoor Units (Nominal Capacity). |
| 405 | Slim type Indoor Unit with fittings equipped with pre- filter, fan section with low noise fan and multispeed motor, drain pump complete as reqd. (Including Corded Remote & Refnets). Vendor to supply shop drawings before starting the works |
| 406 | (a) FXAQ63ARVE6 |
| 407 | (a-1) FXAQ50ARVE6 |
| 408 | SITC of Wired Remotes including fixing on the wall with wooden encloser for locking. |
| 409 | Refrigerant Piping |
| 410 | SITC of interconnecting following sizes of refrigerant copper pipe work refnets, Nitogen pressure testing, Vacuumising, insulated with 19/13 mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units properly fixed/support with suitable size of clamp /M.S. hanger as reqd. |
| 411 | (a) 34.9 mm O.D (insulation -19mm thick) |
| 412 | (b) 28.6mm O.D (insulation -19mm thick) |
| 413 | (c) 22.2mm O.D (insulation -19mm thick) |
| 414 | (d) 19.1mm O.D (insulation -13mm thick) |
| 415 | (e) 15.9mm O.D (insulation -13mm thick) |
| 416 | (f) 12.7mm O.D (insulation -13mm thick) |
| 417 | (g) 9.5 mm O.D (insulation -13mm thick) |
| 418 | (h) 6.4mm O.D (insulation -13mm thick) |
| 419 | SITC of Covered GSS Cable Tray of suitable size for exposed piping . 300 mm width |
| 420 | Drain Piping |
| 421 | SITC of Rigid PVC Piping complete with fittings, supports as perspecifications and duly insulated with 6mm thick closed cell nitrile rubber. |
| 422 | (a) 25 mm dia |
| 423 | (b) 32 mm dia |
| 424 | (c) 40 mm dia |
| 425 | Electrical |
| 426 | Providing & fixing control cum transmission wiring in Heavy Duty PVC 20/25 mm conduit including the cost of buried in wall or in suitable surface, between indoor units and outdoor units. |
| 427 | (a) 2 Core x 1.5 Sqmm Copper wire/Cable |
| 428 | (b) 4 Core x 20 Sqmm Copper wire/Cable |
| 429 | (c) 4 Core x 10 Sqmm Copper wire/Cable |
| 430 | (d) 4 Core x 6 Sqmm Copper wire/Cable |
| 431 | Isolator with weather proof box |
| 432 | (a) 63A |
| 433 | (b) 32A |
| 434 | Supply ofVRV Variable refrigerant Volume modular type outdoor units equipped with highly efficient inverter type compressor(s) , air coolled condenser with special precoated fins type heat exchanger and direct drive low noise propeller fan system suitable for heating / Cooling.Indoor and outdoor units complete as per quantity given below including the cost of floor mounted stand. Electrical equipments suitable 415V 50Hz power supply. Including stands etc. |
| 435 | (a)Outdoor Units (Heat Pump Model) |
| 436 | (a-1) 44 HP Top discharge. Make:- Daikin/ Mitsubishi Electric/Toshiba |
| 437 | Supply of Indoor Units (Nominal Capacity) |
| 438 | Slim type Indoor Unit with fittings equipped with pre- filter, fan section with low noise fan and multispeed motor, drain pump complete as reqd. (Including Corded Remote & Refnets). Vendor to supply shop drawings before starting the works |
| 439 | (a) FXAQ63ARVE6 |
| 440 | (b) FXAQ50ARVE6 |
| 441 | Refnets |
| 442 | SITC of Wireless Remotes |
| 443 | SUB-HEAD-I : EQUIPMENT |
| 444 | Air-cooled ductable units |
| 445 | Supply, Installation, testing and commissioning of following capacityductable type split air-conditioning unit suitable to operate between 380-420 volt, 50 Hz, 3 phase power supply, with air-cooled evaporator with coil, double inlet centrifugal fan with casing of galvanized steel protected with polyster painting and motor protection of IP44 rating. Fan compartment shall be acoustically lined to minimize the dB level.Coils shall be die formed with plate type mechanical bonded aluminium fins to copper tube, expansion valve along with synthetic filter made of washable polypropylene media and insulated drain pan. Air-cooled condenser with hermetically sealed rotary/ scroll compressor(with R-410a/R-407c/R-134a), condenser coil, propeller fans controls, control panel, including control wiring,cordless remote, Necessary supporting arrangement for indoor unit, M.S. frame duly Powder Coated/ Epoxy painted as per approved shade by architect to locate Outdoor Unit with necessary vibration isolation arrangement as per site condition etc. The Unit should be at energy efficient (on the date of procurements, the minimum EER value of the units should be as per ECBC-2017). The Refrigerant pipe size and gas quantity should suit to the copper pipe length at actual.Including stands etc |
| 446 | The capacity guarantee should be ensured by the manufacturer at 45 degree ambient conditions. The provided unit should have inbuilt automatic voltage stabilizer with time delay realy. |
| 447 | Capacities { in TR } are under:- |
| 448 | (a) Auditorium (Ground Floor) 4400 CFM 11 TR |
| 449 | (b) Auditorium (Ground Floor) 2200 CFM 5.5TR |
| 450 | (c) Auditorium (First Floor) 2200 CFM 5.5TR |
| 451 | Refrigerant Piping |
| 452 | SITC of interconnecting following sizes of one end expanded refrigerant copper pipe work of following outer diameter, insulated with 19/13 mm thick closed cell electrometric EPDM/nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification. All piping inside the room shall be propelrly fixed/supported with suitable size of clamp/ M.S. hanger and all external piping shall run in M.S. painted cable tray (Price Extra) etc. as reqd. |
| 453 | (a) 22.2 mm dia with 19mm thick EPDM/nitrile rubber insulation or as per manufacturer recommendation |
| 454 | (b) 28.0 mm dia with 19mm thick EPDM/nitrile rubber insulation or as per manufacturer recommendation |
| 455 | (c) 15.8 mm dia with 19mm thick EPDM/nitrile rubber insulation or as per manufacturer recommendation |
| 456 | (d) 19.0 mm dia with 19mm thick EPDM/nitrile rubber insulation or as per manufacturer recommendation |
| 457 | (e) 9.5 mm dia with 19mm thick EPDM/nitrile rubber insulation or as per manufacturer recommendation |
| 458 | Drain Piping |
| 459 | Providing & fixing of PVC Pipe complete with fittings, supports as per specifications and duly insulated with 9 mm thickness of closed cell nitrile rubber/EPDM as per direction of Engineer-in-charge & specifications enclosed as reqd. |
| 460 | (a) 32 mm dia with 9 mm thick insulation |
| 461 | (b) 40 mm dia with 9 mm thick insulation |
| 462 | (c) 25 mm dia with 9 mm thick insulation |
| 463 | AXIAL FLOW FANS |
| 464 | Supply ,Installation testing and commissioning of Axial Fans with impeller having adjustable pitch angle blades and complete with suitable TEFC motor and drive assembly. The fan shall be suitable for ceiling/floor installation along with spring isolators or as recomended by the manufacturer. Fan motor shall be VFD compatible & shall be of motor efficiency Class IE-2. Motor shall be suitable for 415 ± 10% V, 3 Phase, 50 ± 3%Hz electrical supply.Fan & motor shall be selected for minimum 35mm Static pressure.Total static pressure shall be checked by vendor. Change in static pressure will not attract any price implication. The complete fan assembly alongwith the motor & drive assembly shall be fire rated i.e. suitable to operate upto 250°C for 2 hours and meet the duty parameters.The fan shall be selected for low noise level and low RPMas per technical specifications.Fans shall be AMCA Certified. Price shall also include double sleeve fire retardant flexible connection on both sides of the fan.The fan duty shall be as follows: |
| 465 | (a) Make-up air 12500 CFM 7.5HP |
| 466 | (b) Smoke Exhaust air 12500 CFM 7.5HP |
| 467 | Rectangular GI Ducting (Site Fabricated) |
| 468 | Supply, fabrication, Installation, testing and commissioningofsite fabricated rectangular ducts using G.I Sheets (120GSM coating). The price shall include factory fabricated MS flanges (wherever required), turning vanes, splitter dampers, supports (factory fabricated, full threaded G.I rod/hangers & G.I slotted channel), sealant, neoprene gasket, access door etc.as required and as per ISI specifications.The joints shall be with least leak and shall be tested with pressuretesting machine. |
| 469 | (a) 24 gauge galvanized sheet steel |
| 470 | (b) 22 gauge galvanized sheet steel |
| 471 | (c) 20 gauge galvanized sheet steel |
| 472 | (d) 18 gauge galvanized sheet steel |
| 473 | Supply, Installation and Testing of 125 mm deepAnti-vibration Flexible Joints of imported fire retardant fabric construction with extruded aluminiumframe/ flange on both sides of approved make. |
| 474 | GSS VOLUME CONTROL DAMPER |
| 475 | Supply, installation, testing and balancing of opposed multiblade box type GI volume control damper within ducts to be provided with suitable links, levers and quadrants for ual control of volume of air flow and for proper balancing of the air distribution system as per approved shop drawings & specifications.(All AHUs, fan sections VCD at machine outlets shall be included in the equipment cost only) |
| 476 | NON RETURN DAMPER |
| 477 | Supply, installation, testing and balancing of box type leaf damper within ducts to be provided with suitable levers and quadrants for volume of air flow as per approved shop drawings & specifications. |
| 478 | LINEAR GRILL (FIXED BAR) |
| 479 | Supply, installation, testing & balancing ofremovable core type , continuous, linear, fixed bar extruded aluminium powder coated Supply Air / Return Air grills, normal flow, 0°/15° angle one way deflection with all sides flanges.Blade thickness shall be minimum 5mm in front and 1.0 mm in rear side.Grills shall be supplied in accordance with specifications and approved shop drawings. |
| 480 | (a) 200 mm High |
| 481 | FIXED GRILL |
| 482 | Supply, installation, testing and balancing of powder coated Extruded Aluminium Supply/Return air Grilles with out volume control dampers in accordance with the approved |
| 483 | (a) Powder coated extruded aluminium with adjustable double louvers. |
| 484 | VCDs FOR SUPPLY AIR COLLARS |
| 485 | Supply, installation, testing & balancing ofkey operated extruded Aluminiumvolume control dampers in black mat finish for supply/exhaust air duct collars as per approved shop drawings and specifications. |
| 486 | FRESH AIR INTAKELOUVERS |
| 487 | Supply, installation, testing & balancing of Fresh air Extruded Aluminium intake louvers withbird screen and complete as per specification & approved shop drawings.Construction/profile of the louvers shall give a protection against the rain and suitable for fixing in the external facade of the building. |
| 488 | EXHAUST LOUVERS |
| 489 | Supply, installation, testing & balancing of Exhaust air Extruded Aluminium louvers withbird screen complete as per specification & approved shop drawings.Construction/profile of the louvers shall give a protection against the rain and suitable for fixing in the external facade of the building. |
| 490 | JET DIFFUSER |
| 491 | Supply, installation, testing & balancing ofpowder coated extruded aluminium supply air eye ball type jet diffuser with butterfly type volume control damper of following sizes with fixing accessories,complete asper approved shop drawing andspecifications. |
| 492 | (a) Size : 315mm dia |
| 493 | (b) Size : 400mm dia |
| 494 | SUB-HEAD - INSULATION WORK |
| 495 | Supply and application FR, AL foiled Closed Cell chemically Cross linked Polyethylene thermal insulation material. Volume percentage of Closed Cell not less than 90%.The Nominal Density of Material Should be 25 to 30 kg/m³, having a thermal conductivity of 0.0328 w/m°k at 23°C,mean temperature. The material shall conform to BS 476 parts 7, in a manner to be classified as ‘Class 1’.water Vapour Permeability , µ Factor for foil faced material shall be> 14000 as per DIN 52615. Insulation to be applied using manufacturer\"s recommended Adhesive in a blend of solvents. |
| 496 | (a) 19mm thick on supply air duct |
| 497 | Supply and Application of Acoustic Insulation Inside the Duct with Non Fibrous fire retardant, Open cell, cross-linked polyethylene foam of 30+/- 3 Kg/m3 density, NRC 0.28 min having porous surface on one side & a flat surface on other side using Synthetic rubber based Adhesive preferably Low VOC & high strength characteristic.; to be applied using manufacturer\"s recommended Adhesive in a blend of solvents. |
| 498 | (a) 12mm thick |
| 499 | SUB-HEAD : ELECTRICAL WORK |
| 500 | Preamble to BOQ - specification for MCC, Distribution Boards & wall mounted Starter Panels mention below. |
| 501 | General Notes & Specifications as given below shall be applicable to all panels. The vendors shall consider the below mention following details in their item rates, wherever required: |
| 502 | Supporting rigid steel framework. |
| 503 | Cubicle type, 14 gauge CRCA sheet steel enclosure. |
| 504 | Panel Complete with interconnections and distribution bus bars. |
| 505 | Proper bonding to earth. |
| 506 | Painting/lettering on Breakers and distribution boards, the location they serve, Providing on each panel its circuit diagram. |
| 507 | Providing cable clamps / supports within distribution boards cable alley. |
| 508 | TPN MCCBs shall mean 3 pole MCCBs with adequate size of neutral link. |
| 509 | All MCBs shall be of minimum 10 KA breaking capacity. |
| 510 | All motor feeders MCCBs shall be of motor duty. |
| 511 | Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5. |
| 512 | Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. |
| 513 | IP 52 for indoor panels. |
| 514 | IP 55 for outdoor panels with double door enclosure. |
| 515 | All MCCB’s shall be provided with operating mechanism for door interlock. |
| 516 | Current density of aluminium shall be 1 sq mm for 1.0 amps for rated current of bus bars and current density of copper shall be 1 sq.mm for 1.25 amps for rated current of bus bars. |
| 517 | Tinned copper earth bus shall be provided through out the length of each board. |
| 518 | All measuring instruments (Meters) shall be of digital electronic with LED of approved make and compatible with BAS. |
| 519 | All indicating lamps shall be LED type. |
| 520 | All current/voltage transformers shall be cast resin type. |
| 521 | All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. |
| 522 | All panels shall have provision of the following: |
| 523 | Pad locking of Switch board doors. |
| 524 | Pad locking of MCCB’s handles in “OFF” Position. |
| 525 | Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided for BAS including space required for various transducers in Main Switch Board sections. Only transducers shall be supplied by BAS contractor. |
| 526 | All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. |
| 527 | All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. |
| 528 | All PTs / control transformers shall be provided with centre tap earth secondary. |
| 529 | All DOL & Star-Delta Starters shall be provided with voltage based SPPR (single phase preventor relay) and 2 nos. of Aux.Contacts for Remote operation/monitor. |
| 530 | The Panel fabricator shall provide Aluminium Bus-bars link from Breakers wherever more than two nos. of cables are terminated in the breakers. |
| 531 | Readymade 16SWG Sheet steel Enclosure with cutout For MCBs |
| 532 | The breaking capacity of MCCB’s shall bementioned panel wise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise. |
| 533 | All internal control wiring shall be heat resistant type. |
| 534 | Bus bar chamber shall be provided at top only. Incoming and outgoing cable entry shall be from top/bottom as required. |
| 535 | Live parts shall not be accessible after opening the door, Transparent acrylic sheet to be provided to cover the same. |
| 536 | Spare contacts of ACBs / MCCBs / Relay / Contactor shall be wired upto terminal block. |
| 537 | All Switchgear used in Starter Circuit shall be type-2 coordinated. Contactor rating shall be selected as per the kVAR rating of the capacitor bank from capacitor duty contactor range. Vendor to furnish the type-2 coordination chart and capacitor duty contactor selection chart. |
| 538 | Protection Releases Microprocessor based (PRMB) & Thermal magnetic (PRTM) shall be as describe below . |
| 539 | Protection Release Microprocessor Based (PRMB-1) |
| 540 | Over-current/long time protection range 105% - 120 % with Time setting |
| 541 | short circuit /short time protection range 100% - 1000 % with Time setting |
| 542 | Instantaneous short circuit Protection range 200% - 1500 % with Time setting |
| 543 | Earth Fault Protection range 20% - 100 % with Time setting |
| 544 | Under voltage & over voltage protection |
| 545 | Reverse power |
| 546 | Current unbalance |
| 547 | Phase sequence |
| 548 | Measurements |
| 549 | Voltage |
| 550 | Current |
| 551 | Power (Active,Reactive & Apparent) |
| 552 | Energy ((Active,Reactive & Apparent) |
| 553 | Power factor |
| 554 | Frequency |
| 555 | Protection Release Microprocessor Based (PRMB-2) |
| 556 | Over-current/long time protection range 105% - 120 % with Time setting |
| 557 | short circuit /short time protection range 100% - 1000 % with Time setting |
| 558 | Instantaneous short circuit Protection range 200% - 1500 % with Time setting |
| 559 | Earth Fault Protection range 20% - 100 % with Time setting |
| 560 | Measurements |
| 561 | Current |
| 562 | Protection Release Microprocessor Based (PRMB-3) |
| 563 | Over-current/long time protection range 105% - 120 % with Time setting |
| 564 | Instantaneous short circuit Protection range 200% - 1500 % with Time setting |
| 565 | Protection Release Thermal-Magnetic Based (PRTM) |
| 566 | Over-current |
| 567 | Short circuit |
| 568 | SMOKE EXTRACTION FAN STARTER PANEL |
| 569 | Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted Fan starter panels including anchoring into the wall with following details: |
| 570 | All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operation through BAS. All starters shall be provided with potential free Contacts for Connections to Building Automation System. |
| 571 | The panel shall include the following components and accessories. |
| 572 | 14G CRCA Powder Coated panel enclosure with earthing studs & hinged locable doors. IP52 Protection, suitable for 415V, 3 Phase, 4 wire, 50Hz system. |
| 573 | Incomer switch shall be TPN MCB (motor duty) of required rating & 10KA fault withstand capacity up to 11.0 KW motor rating and TPN MCCB (motor duty) of required rating & 20KA fault withstand capacity beyond 11.0 KW. MCB/MCCB shall be with overload & short circuit protection. |
| 574 | R,Y,B LED Type Phase indication lamps with control MCB\"s. |
| 575 | ON\"/OFF/TRIPIndication LED Type lamp with control MCB. |
| 576 | DOL/Star-deltastarter for the ratings given belowcomplete with contactors,over load relay with built in single phase protection. Starter shall be BMS compatible for Remote ON/Off & status monitoring complete with Auto/manual switch. |
| 577 | For on/off/remote and local operation, 3 pole single throw switch shall be provided in each Fan panel to facilitate override of the automatic operation. |
| 578 | A fire detection relay module for switching \"ON\" of Fan motor on receiving fire signal & fire damper interlocking. Necessary nos. of auxillary contactors & Relays shall be included in cost as required for the interlocking with AHU fan motor & motorised firedampers. |
| 579 | 240/24V AC Step down transformerfor powering24V AC auxillary relay. |
| 580 | Terminal block for power distribution. |
| 581 | Note: Vendor to include the cost of all related power& control cabling on GI cable tray along with copper earthing ,from Axial flow fan motors, Exhaust fan sections, to control panels. (For sizes of cables , refer to the detailed specifications of Electrical section). |
| 582 | DOL starters upto 5.5 KW & beyond star-delta starter shall be considered. |
| 583 | The no. of Fan control panels/starters shall be as per KW ratings given below: |
| 584 | Suitable rating MCB , Starter Panel for 5.5 KW Motor |
| 585 | SITC Isolator Switches With Metal Enclosure For Outdoor Units |
| 586 | (a) 40 A TPN isolator switch for equipments with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation.) |
| 587 | (b) 32 A TPN isolator switch for equipments with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation.) |
| 588 | Additional works in Main panel. |
| 589 | (a) Out Going |
| 590 | (a-1) SITC 1 No. 400 A TPN MCCB (35 kA) suitable to receive 3.5C x 185 sq mm AYFY Cable .(Note:- Including disconnecting the existing & coneecting the new cable). |
| 591 | CCTV Works |
| 592 | SITC CP PLUS 4MP Full HD IP Network Dome camera:Image Sensor: 4 MP CMOS, Max. outputs 4MP(2688×1520)@50fps/60fps, Instastream/H.265/Smart H.264+/H.264 coding,3.6mm fixed lens, Day/Night Mode: Auto/Color/BW (Black and White), Operating Condition: -40° C to 60° C (-40° F to 140° F), Humidity 90% or less (no condensation), Power Supply: 12 VDC ± 25% or PoE .Make:- CP Plus, Bosch, Hikvision, Dahua, D-link. |
| 593 | SITC CP PLUS 4MP Full HD IP Network Bullet camera: Image Sensor: 4 MP CMOS, Max. outputs 4MP(2688×1520)@50fps/60fps, Instastream/H.265/Smart H.264+/H.264 coding,3.6mm fixed lens, Day/Night Mode: Auto/Color/BW (Black and White), Operating Condition: -40° C to 60° C (-40° F to 140° F), Humidity 90% or less (no condensation), Power Supply: 12 VDC ± 25% or PoE .Make:-CP Plus, Bosch, Hikvision, Dahua, D-link. |
| 594 | SITC Hikvision 32 Channel NVR:Up to 32-ch IP camera inputs, H.265+/H.265/H.264+/H.264 video formats, 1 HDMI and 1 VGA interfaces, both interfaces support independent video output, 1 HDMI and 1 VGA interfaces, both interfaces support independent video output, 2SATA port. Make:- CP Plus, Bosch, Hikvision, Dahua, D-link. |
| 595 | SITC Hikvision 8 Channel NVR:Up to 8-ch IP camera inputs, H.265+/H.265/H.264+/H.264 video formats, 1 HDMI and 1 VGA interfaces, both interfaces support independent video output, 1 HDMI and 1 VGA interfaces, both interfaces support independent video output, 1 SATA port Make:- CP Plus, Bosch, Hikvision, Dahua, D-link. |
| 596 | SITC Hard Disk 6 TB Seagate. Make:-Skyhawk / WD Purple |
| 597 | SITC Hard Disk 4 TB Seagate .Make:-Skyhawk / WD Purple |
| 598 | SITC PoE switch CP PLUS / DLINK 8+2. Make:-Gigabit |
| 599 | SITC PoE switch CP PLUS / DLINK 16+2 Make:-Gigabit |
| 600 | SITC Gigabit Ethernet Switch 8 port 10/100/1000 Mbps Dlink |
| 601 | SITC Wire Cat6 Dlink Unarmored (100% copper) |
| 602 | SITC Connectors Video & Power with CCTV junction box |
| 603 | SITC Network Enclosure Rack with PDU & Fan for PoE switch & NVR |
| 604 | Laying of Data/camera cable in PVC conduit (inlcuding the cost of PVC pipe) of required dia.Pipe as approved by EIC. |
| 605 | SITC Display monitor Full HD 32 inch. Make:-Acer / Dell / Samsung / LG) |
| 606 | Accessories:- Consumable accessories LIKE Cable tie, tape, screws, nails, fastners, steel wire etc. required in complete camera work installation . |
| 607 | SITC HDMI Extension & USB extension for display at Principal room |
| 608 | Providing and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25mmConduit Make:- Supreme, Prakash, Setia, AKG, Polypack. |
| 609 | Supply, Drawing, Connecting, Testing and Commissioningwith laying of TV Co-axial cable RG 59 in conduit for CCTV System. Including the cost of connection with main controller of college. |
| 610 | FIRE FIGHTING SYSTEM |
| 611 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 612 | a) 80 mm dia |
| 613 | b) 100 mm dia |
| 614 | c) 150mm dia |
| 615 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 616 | a) 80 mm dia |
| 617 | b) 100 mm dia |
| 618 | c) 150mm dia |
| 619 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 620 | a) 80 mm dia |
| 621 | b) 100 mm dia |
| 622 | c) 150mm dia |
| 623 | Supplying and fixing First Aid Hose Reel, wall mounting swinging type completewith drum & bracket of MS construction, spray painted in Post office Red, confirming to IS : 884/1995 with upto date ammendments, complete with the following as required. |
| 624 | 36 Meter long 20min dia water those Thermoplastic (Textile rienforced) Type- 2 as per IS: 12585 |
| 625 | 20 mm dia gun metal ball valve & nozzle |
| 626 | Drum and brackets for fixing the equipments on wall |
| 627 | Connection from riser with stop valve (gun metal) & M.S. Pipe |
| 628 | Providing and fixing fire extinguisher of carbondioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve baring IS:3224/15683 mark internal discharge tybe, 1 metre long high pressure discharge hose, non conduction horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed |
| 629 | a) 4.5kg capacity cylinder |
| 630 | Providing and fixing 9 liters capacity fire extinguisher water type gas pressure conforming to IS markingfixed to wall |
| 631 | Providing and fixing ABC type fire extinguishers complete in all respects. |
| 632 | a) Capacity 5.0 Kg |
| 633 | Furniture |
| 634 | Providing & laying Student Desk of Width 1800mm ( 6\"0\") having Top (1800mm x350 mm), Seat (1800mm x 300mm), Back (1800mm x 230mm) & Book Shelf ( 1800mm x 250mm) in 22mm thick Teak wood and 14 gauge M.S. frame of 35mm x 35mm square pipe. The design is approved by EIC/Architect.Make:- Rockworth, Godrej, Wipro, wesource. |
| 635 | Providing, making and fixing Tables for Delgates for Rooms ofSizes (600mm x 1800mm x 750mm) in 19 mm thick HDHMR Board and 150 mm high cable alley on table top for Data(3Nos.) & Electrical (6Nos.) with modoular switch- socket including box, Face plate, wire ( 2.5 sqmm & cat 6) with SITC . Make necessary cutouts for electrical and data cables wherever required. Provide groove patties, mouldings etc. as per drawings. The teak wood mouldings and lippings on edges to be finished in melamine polish as per instructions. The tabletop, sides and the front portions, inner sides of the table is to be finished with 1 mm thick laminate of approved shade and quality. |
| 636 | Rooms Chair: Providing & Supplying ergonomically comfortable and aesthetically designed medium back chair. The back is made of Polypropylene and upholstered with breathable fabric tapestry. The seat is made of 12mm thick wooden ply & PU foam density 40+/-2 kg/m3 upholster with fabric tapestry. Seat and back joint by HRC sheet cover with PP below. Armrests are made of polypropylene and cantilever shape frame is made of CRCA metal pipe dia. 28.5mm x 2mm thick duly epoxy powder coated with 40-50 micron thickness. Seat Size depth-18\" width-19\" and back height -17\". Overall height 35\". Whole CRCA metal frame quality to meet desired strength and rigidity. Make:- Rockworth, Space wood, Godrej, HNI, Wipro, wesource. |
| 637 | Providing making and fixing Teacher table of 1200mm (L) x 750mm (D) x 750mm (H), in 18 mm thick HDHRM Board.The table top, sides and the front portions, inner sides of the table and drawers is to be finished with 1 mm thick laminate of approved shade and quality. Provide 1no. drawer and storage with shelves with front openble shutter at under table cupboards as per design. The drawer will have bottom of 6 mm and sides of 12 mm HDHRM board & Drawer run on S.S. sliding channe of approved make. Table top should have necessary cutouts for electrical and data cables wherever required. Provide groove, lipping, mouldings etc. as per drawings. The teak wood mouldings and lippings on edges to be finished in melamine polish as per instructions. Provide & fixing of necessary hardware like SS.hinges, magnetic ball catcher, s.s. sliding Channel, S.S.handles & 3 nos. locks. |
| 638 | Over Head Wall Storage: |
| 639 | Providing & fixing over Head Wall Storage cabinets in position as per drawing enclosed. The cabinets shall be 16” deep and out of 18 mm HDHMR board. The back and the shutters shall be made out of 18 mm HDHRM board respectively. Shelves to be provided as per requirements inside as per design/approval. All the external and internal surfaces including the edges shall be finished with 1 mm thick laminate. One Open shelves of 8\" wide along the length of storage is to be also provided under the over head storageAll the necessary fittings like SS hinges, magnetic ball catcher, locking arrangement, ss handles tower bolts etc. are to be provided and are to be provided as per direction of Engineer-in-Charge / Architect. (Front area is measured for payment) |
| 640 | High Wall Storage: |
| 641 | Providing & fixing High Wall storage Cabinets in position as per drawing enclosed. The cabinets shall be 22” deep and out of 19 mm HDHRM board. The back and the shutters shall be made out of 18 mm HDHRM board respectively. 18 mm thk HDHMR board Shelves to be provided as per requirements inside as per design. All the external and internal surfaces including the edges shall be finished with 1 mm thick laminate. All the necessary fittings like SS hinges, magnetic ball catcher, locking arrangement, ss handles ( 4\"),tower bolts etc. are to be provided and are to be provided as per direction of Engineer-in-Charge / Architect. |
| 642 | Providing making and fixing of shelves / partitions. All the shelves / partitions to made out of 19 mm HDHRM board with external surface including the edges laminated with of approved shade of 1 mm thick laminate as per direction of Engineer-in-Charge / Architect. |
| 643 | Providing making and fixing table of following sizes in 18 mm thick HDHMR Board as per drawing enclosed. Provide drawers and storage cupboards as per design under the table; provide a centrally placed keyboard drawer wherever required below the main tabletop. All the drawers to have bottom of 6 mm and sides of 12 mm HDHRM board. Make necessary cutouts for electrical and data cables wherever required. Provide groove patties, mouldings etc. as per drawings. The teak wood mouldings and lippings on edges to be finished in melamine polish as per instructions. The tabletop, sides and the front portions, inner sides of the table and drawers is to be finished with 1 mm thick laminate of approved shade and quality. All the drawers to have bottom of 6 mm and sides of 12 mm HDHMR board and are to be provided with channels and locks as specified. Provide the necessary hardware like hinges, magnetic ball catcher handles. |
| 644 | a) Computer work stations800 mm wide 750mm high with space for CPU and 150 mm high cable alley on table top |
| 645 | b) Work stations800 mm wide 750 mm high with 150 mm high cable alley on table top |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy