Tender For Fire Alarm System Of Gani Kashmiri Scholars Hostel At Main Campus, Srinagar-Jammu And Kashmir

University Of Kashmir (Jammu) has published Tender For Fire Alarm System Of Gani Kashmiri Scholars Hostel At Main Campus. Submission Date for this Tender is 04-12-2023. Alarm Systems Tenders in Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

40787527
Tender For Fire Alarm System Of Gani Kashmiri Scholars Hostel At Main Campus
Open Tender
Indian
Jammu And Kashmir
Srinagar
04-12-2023

Tender Details

Tender For Fire Alarm System Of Gani Kashmiri Scholars Hostel At Main Campus , Fire Alarm System Supplying And Fixing Of Following Sizes Of Heavyduty Class Conduit Along With Accessories In Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm. , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Two Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 2 Core 1.5 Sq. Mm , Supply, Installation, Testing And Commissioning Of Multi Loop Adress Upto 150 Modules Conventionalfire Alarm Control Panel Complete Withdisplay, With Sufficient Panel Enclosure And Cabinet Size. The Panel Shall Be Able To Givelocation Ofall Fire / Fault Conditions Of Addressable Units Via The Address Codes. Further, The Panel Must Be Able To Automatically Switch On / Off Respective Control Modulewhen Ever Any Alarm Is Triggered.The Panel Shall Have Rectifier, Loop Cards, L C D Unit To Indicate Fire / Fault Signal With Addressand Analog Output, External / Inbuilt Printer To Log All Fire Or Fault Events Complete In All Respects. The Panel Shall Have A Built In Power Supply And Battery Charger Along Withmaintenance Free Battriest Smf Lead Acid Batteries Capable Of Running For A Minimum Of 8 Hours With Battery Charger Complete As Required. Panel Shall Be Able To Sense & Indicate Fire Or Fault. , Supplying And Fixing Ofjunction Boxes In Slab For Detectors , Supply, Installation, Testing And Commissioning Ofmulti Criteria Smoke Cum Heat Detector, Opticaltypewith Blinking Led And Being Capable Of Being Addressed Electronically. Manual Addressing ( Dip / Rotary Switches ) Not Acceptable, With Mounting Base. Below False Ceiling , Supply, Installation, Testing And Commissioning Ofdouble Action Manual Pull Station Capable Of Being Addressed Electronically. Manual Addressing ( Dip / Rotary Switches ) Not Acceptable, Complete As Required. , Supply, Installation, Testing And Commissioning Offire Alarm Hooter ( Sound Output Of Minimum 90 Db Upto A Distance Of 30 Meters ) , Made Addressable With The Help Of Intelligent Addressable Signal Module, Capable Of Being Addressed Electronically. Manual Addressing ( Dip / Rotary Switches ) Not Acceptable, With Seperate Power Supply Arrangement Complete As Requiredand Suitable For Wall / Ceiling Mounting. , Supply, Installation, Testing And Commissioning Offault Isolator Module Complete As Required For Determining The Short In A Circuit And Separating The Segment Having The Short Capable Of Being Addressed Electronically. Manual Addressing ( Dip / Rotary Switches ) Not Acceptable, Complete As Required. , Supply, Installation, Testing And Commissioning Ofcontrol Module Complete As Required For Driving Hooters, Capable Of Being Addressed Electronically. Manual Addressing ( Dip / Rotary Switches ) Not Acceptable. , Providing And Fixing Of 4.5Kg. Capacity I.S.I. Marked. ( Is : 15683 ) Carbon-Di-Oxide Fire Extinguishers Consisting Of Welded M.S Cylinderical Body, Squeeze Lever Discharge Valve Fitted With Internal Discharge Tube, 30Cms Long Isi Marked High Pressure Discharge Hose, Dischargenozzle, Suspension Bracket, Confirmingto Is: 934 Finished Externally With Redenamelpaint Andfixed Towall With Brackets With Rawl Plug / Dash Fasteners Complete With Internal Charge. , Portable Fire Extinguishers Providing And Fixing Abc Stored Pressure Dry Chemical Powder ( Monoammonium Phosphate ) Fire Extinguisher Is : 13849 Latest Revision Manufacturer And Of Crca Sheet In Welded Construction, Finish With Epoxy Polyster Powder Coated Complete With Brass Forged Ball Valve, Gun Metal Cap And Nozzel, Including Initial Filled And Wall Suspension Bracket ( Suitable For Fighting In Class A, B & C That Is Wood, Textile, Flammable Liquid, Electric And Gases. 4 Kg. Capacity , Supplying, Fixing Of Automatic Fire Fighting Ball “Techideas” Elide Fireor Equivalent Abc Type Extinguishing Ball, Automatic Fire Extinguishing Technology. Automatic Fire Fighting Ball Size ( Diameter. ) 6 Inches. Or 152 Mm. ( Elb01 ) Weight ( Kg. ) 1.3 Kg. + / - 0.2 Kg. Coverage Area 4 Sq. Meter Radius 360 Degree Installation Ambient Temperature -40 C° Up To +85 C° Service Life Of Automatic Fire Surveillance ( Years ) 5 Years Operating Time ( Sec. ) 3-5 Seconds Operating Temperature 280 C° Or Touching The Flame Etc. Including Providing, Fixing Of Suitable Holding Stand For Same , Note. The Quoted Percentage ( %Age ) Should Preferably Be In Fractional Form In Order To Minimize Concurrence Of Similar Quoted Rates

Key Value

Document Fees
INR 200 /-
EMD
INR 7380.0 /-
Tender Value
INR 3.69 Lakhs /-

BOQ Items

Name of Work: Fire Alarm System of Gani Kashmiri Scholars Hostel at Main Campus (Advertised cost Rs. 3.69 Lacs)
Sl. No. Item Description
1FIRE alarm SYSTEM Supplying and fixing of following sizes of heavyduty class conduit along with accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm.
2Supplying and drawing following sizes of FRLS PVC insulated copper conductor, two core cable in the existing surface/ recessed steel / PVC conduit as required. 2 core 1.5 sq. mm
3Supply, installation, testing and commissioning of multi loop adress upto 150 modules conventionalFire Alarm Control Panel complete withDisplay, with sufficient panel enclosure and cabinet size. The panel shall be able to givelocation ofall fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control modulewhen ever any alarm is triggered.The panel shall have rectifier, Loop cards, L C D unit to indicate Fire/Fault Signal with addressand analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The panel shall have a built in power supply and battery charger along withmaintenance free battriest SMF Lead acid batteries capable of running for a minimum of 8 hours with battery charger complete as required. Panel shall be able to sense & indicate fire or fault.
4Supplying and fixing ofjunction boxes in slab for detectors
5Supply, installation, testing and commissioning ofMulti Criteria Smoke cum Heat Detector, opticaltypewith blinking LED and being capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, with Mounting Base. Below false ceiling
6Supply, installation, testing and commissioning ofDouble action manual pull station capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, complete as required.
7Supply, installation, testing and commissioning ofFire Alarm Hooter (sound output of minimum 90 dB upto a distance of 30 meters),made Addressable with the help of Intelligent Addressable Signal Module, capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, with seperate power supply arrangement complete as requiredand suitable for wall/ceiling mounting.
8Supply, installation, testing and commissioning ofFault isolator module complete as required for determining the short in a circuit and separating the segment having the short capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, complete as required.
9Supply, installation, testing and commissioning ofControl Module complete as required for driving hooters, capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable.
10Providing and fixing of 4.5kg. capacity I.S.I. Marked. (IS : 15683) Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long ISI marked high pressure discharge hose, dischargenozzle, suspension bracket, confirmingto IS: 934 finished externally with redenamelpaint andfixed towall with brackets with rawl plug/dash fasteners complete with internal charge.
11PORTABLE FIRE EXTINGUISHERS "Providing and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS : 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzel, including initial filled and wall suspension bracket (suitable for fighting in class "A", B & "C" that is wood, textile, flammable liquid, electric and gases. 4 Kg. Capacity
12Supplying, fixing of Automatic fire fighting ball “TECHIDEAS” ELIDE FIREor equivalent ABC type extinguishing ball, automatic fire extinguishing technology. AUTOMATIC fire fighting ball Size (Diameter.) 6 inches. or 152 mm. (ELB01) WEIGHT (Kg.) 1.3 Kg. +/- 0.2 Kg. COVERAGE AREA 4 sq. meter radius 360 degree Installation ambient temperature -40 C° up to +85 C° Service life of automatic fire surveillance (years) 5 years Operating time (sec.) 3-5 seconds Operating temperature 280 C° or touching the flame etc. including Providing, fixing of suitable holding stand for same
13Note. The quoted percentage (%age) should preferably be in fractional form in order to minimize concurrence of similar quoted rates
Disclaimer :