Rate Contract For Oil Purification Units For Trolley Type, Stg Type And Power Projects Type Opus , Trolley Type Opu - Varaint 1 , Oil Centrifuge Assy(T) 1000Lph, Iic Ie3 Motor , Pressure Gauges (20% (Subject To Minimum Of 2 Nos.) For Each Type, Range, Material Of Construction, Size, Rating And Length Of Capillary); (Pi At Centrifuge Inlet And Exhaust: 2Nos Each) , Temperature Gauges (20% (Subject To Minimum Of 2 Nos.) For Each Type, Range, Stem Length And Length Of Capillary.) (Tg At Centrifuge Inlet : 2Nos Each) , Solenoid Valves 10% (Subject To Minimum Of 2 Nos.) For Each Type. , Panel Mounted Instruments ; 10% (Subject To Minimum Of 2 No.) For Each Type. Hooter:- 10% (Subject To Minimum Of 2 No.) For Each Type Annunciators:- E) Lamps: 10% Of Total Quantity. , Pulsating Dampener, Snubber, Syphon, Gauge Saver Etc. 20% (Subject To Minimum Of 2 No.) For Each Type. , Safety Relief Valves: 10% (Subject To Minimum 1 No.) For Each Type , Pipe Fittings, Flanges & Valves (5% Of Installed Qty Or Minimum 1 No.) , Set Of Bearings (Nde + De) For All Opu Motor , Set Of Terminal Studs & Bushing Assy. For Motors , Set Of Cooling Fans For All Opu Motors , Terminal Block (Including Terminal Box Cover With Screws) For All Opu Motors , Set Of Cooling Fan Cover , Spare Fuse Of Opu Skid , Spare Mcb Of Opu Skid (10% Of Installed Qty) , Terminal Block For Opu Local Panel , Housing Inner Cover (De) For Opu Mtr , Housing Outer Cover (De) For Motor , Housing Inner Cover (Nde) For Motor , Housing Outer Cover (Nde) For Motor , Circlip Sets For Opu Motor , Trolley Type Opu - Varaint 2 , Oil Centrifuge Assy(T) 1600Lph, Iic Ie3motor , Pressure Gauges (20% (Subject To Minimum Of 2 Nos.) For Each Type, Range, Material Of Construction, Size, Rating And Length Of Capillary); (Pi At Centrifuge Inlet And Exhaust: 2Nos Each) , Temperature Gauges (20% (Subject To Minimum Of 2 Nos.) For Each Type, Range, Stem Length And Length Of Capillary.) (Tg At Centrifuge Inlet : 2Nos Each) , Solenoid Valves 10% (Subject To Minimum Of 2 Nos.) For Each Type. , Panel Mounted Instruments ; 10% (Subject To Minimum Of 2 No.) For Each Type. Hooter:- 10% (Subject To Minimum Of 2 No.) For Each Type Annunciators:- E) Lamps: 10% Of Total Quantity. , Pulsating Dampener, Snubber, Syphon, Gauge Saver Etc. 20% (Subject To Minimum Of 2 No.) For Each Type. , Safety Relief Valves: 10% (Subject To Minimum 1 No.) For Each Type , Pipe Fittings, Flanges & Valves (5% Of Installed Qty Or Minimum 1 No.) , Set Of Bearings (Nde + De) For All Opu Motor , Set Of Terminal Studs & Bushing Assy. For Motors , Set Of Cooling Fans For All Opu Motors , Terminal Block (Including Terminal Box Cover With Screws) For All Opu Motors , Set Of Cooling Fan Cover , Spare Fuse Of Opu Skid , Spare Mcb Of Opu Skid (10% Of Installed Qty) , Terminal Block For Opu Local Panel , Housing Inner Cover (De) For Opu Mtr , Housing Outer Cover (De) For Motor , Housing Inner Cover (Nde) For Motor , Housing Outer Cover (Nde) For Motor , Circlip Sets For Opu Motor , Stg Type Opu - Varaint 1 , Oil Purification Unit, Fxd,1000Lph,415V Ac, Without Heater & Polishing Filter, As Per Attached Drg 23080000044-S00-R00 (Hydg- 3-31101-25021-S00-R01) , Spare Set Of Gasket For Each Pump Of 1000 Lph Centrifuge; , Stg Type Opu - Varaint 2 , Oil Purification Unit, Fxd,2400Lph,415V Ac, Without Heater & Polishing Filter, As Per Attached Drg 23080000044-S00-R00 (Hydg- 3-31101-25021-S00-R01) , Spare Set Of Gasket For Each Pump Of 1000 Lph Centrifuge; , Stg Type Opu - Varaint 3 , Oil Purification Unit, Fxd,1600Lph,415V Ac, Without Heater & Polishing Filter, As Per Attached Drg 23080000044-S00-R00 (Hydg- 3-31101-25021-S00-R01) , Spare Set Of Gasket For Each Pump Of 1000 Lph Centrifuge; , Power Sector Type Opu - Varaint 1 , Oil Purf. Skid 2400Lph-Comp Ss-Dcs , Terminal Plate For All Opu Motors , Bearings De & Nde All Opu Mtr , Spare Ie2 Mtr For Centrifuge And Pump , Cooling Fan For All Opu Motors , End Shield Cover For All Opu Motors , Type Test Of One No Of Oil Purification Unit As Per Approved Test Procedure