| 1 | Excavation in post holes not exceeding 0.5 cum each getting out , returning filling in and ramming earth around in layers not exceeding 25 cm each all as specified in hard/dense soil including removalof surplus soil upto 50 mtrs distance complete all as specifiedand directed by Engineer-in-Charge. |
| 2 | Supply and fixing Fe 410-w(Gde E 250)quality B rolled mild steel in roof trusses (framed) trussed, purlins, crane gantries, rails and framing (beam, tee, angle, channel or flat sections) including distance pieaces cleats complete all as specifiedand directed by Engineer-in-Charge. |
| 3 | Supply and fixing MS plates Fe 410-W(Gde E 250) quality Aplain or chequered square cut or notched forming holes drilled or welded any thickness complete all as specifiedand directed by Engineer-in-Charge. |
| 4 | Material & labour for Painting to steel surfaces with synthetic enamal paint over one coat of redoxide primer complete all as specifiedand directed by Engineer-in-Charge. |
| 5 | Material & labour PCC Type D-2 (1:4:8) in foundations, filling and mass concrete complete all as specifiedand directed by Engineer-in-Charge. |
| 6 | Material & labour for cement concrete 1:3:6 Type C-2 as in foundations filling and mass concrete complete all as specifiedand directed by Engineer-in-Charge. |
| 7 | Supply and fixing 0.63mm thick galvanised, corrugated mild steel sheeting with two corrrugations side lap, fixed with coach screws and washers, in roofs, wall etc. with grade of zinc coating 275 complete all as specifiedand directed by Engineer-in-Charge. |
| 8 | Supply and fixing 0.63mm thick galvanised, plain mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specifiedand directed by Engineer-in-Charge. |
| 9 | Material & labour for preparation of new steel and iron surfaces of any description over 10 Cm width or girth not otherwise described and applying two coats of synthetic enamel paint (camouflaged pattern) over a coat of red oxide primer over a coat of moderant solution to remove zinc coating complete all as specified and directed by Engineer-in-Charge |
| 10 | Dismantling floor hearth wall tiling (but not backing) removing servicable tiles to store rubbish off the premisses complete all as complete all as specifiedand directed by Engineer-in-Charge. |
| 11 | Material & labour screed bed or bedding layer of mortar 15mm thick in cement mortar (1:4) complete all as specifiedand directed by Engineer-in-Charge. |
| 12 | Material & labour for coloured chequered cement concrete tiles 22 to 25mm thick, set jointed and pointed in neat cement slurry in floors, with grey cement and pigment complete all as specified and as directed by the Engineer-in-Charge |
| 13 | Material & labour for 100mm thick PCC 1:4:8 type B-1 (using 20mm graded aggregate),as in sub base complete all as specified by Engr-in-charge. |
| 14 | Material & labour for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded aggregate),finishedeven and smooth without using extra cement complete all as specified.as in floors complete all as specified by Engr-in-charge. |
| 15 | Material & labour brick work with sub class \"B\" bricks in CM 1:6, straight or curved on plan exc 6 mtr nean radius, using old size bricks complete all as specifiedand directed by Engineer-in-Charge. |
| 16 | Material & labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specifiedand directed by Engineer-in-Charge. |
| 17 | Material & labour for preparation of new plastered surfaces and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/lit and UV resistance as per IS 15879 ; 2004, Alkali and fungal resistance , dirt resistance exterior paint of requirede shade (Company Depot Tinted) with silicon additives @1.43lit/10sqm over and including priming coat of exterior primer [email protected]/10sqm over new surfaces complete all as specifiedand directed by Engineer-in-Charge. |
| 18 | Material & labour for Preparation new surfaces of walls and applying two coats of oilemulsion distemper over a coat of 3 mm thick wall putty complete all as specifiedand directed by Engineer-in-Charge. |
| 19 | Material & labour for PCC 1:3:6 Type C1(using 20 mm graded aggregate) as in wall or retaining wall, any thickness, size or shape including pilasters buttresses columns, pillars boundary pillars andposts (including caps and bases) complete all as spefcified and as directed by the Engineer-in-Charge. |
| 20 | Material & labour for formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc, verical or to batter, work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engneer-in-Charge |
| 21 | Supply and fixing PVC (SWR) pipes single socketed, in any length of 110mm bore with rubber ring joints, laid in wall & trenches ,complete all as specifiedand directed by Engineer-in-Charge. |
| 22 | Material & labour for boulder filling dry, hand packed tightly, guage exc 80mm and n exc 150mm as in backfilling of retaining wall complete all as specifiedand directed by Engineer-in-Charge. |
| 23 | Material & labour for surface point wiring on wall and surface on ceiling/roof with necessary fixing arrangements withPVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dollyand bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mountingfittings, door bell & bulkhead/telephone socket etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge. |
| 24 | Surface submain wiring with two single core PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 1.5 Sqmm as earth lead in & includingnon metallicPVC conduit medium grade with all conduit accessores as per specification all as required at site or directed by Engr-in-charge. |
| 25 | Material & labour for switch piano flush button single pole one way 5 amps 240 voltscomplete all as specifiedand directed by Engineer-in-Charge. |
| 26 | Material & labour for ceiling rosesurface bakelite 3 terminals complete all as specifiedand directed by Engineer-in-Charge. |
| 27 | Supply and fixingdecorative ultra slim LED tube light fitting with extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver of 20/22watt (4\") in and including 20/22 watt LED tube rod complete withall accessories prewiredand connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core complete all as specifiedand directed by Engineer-in-Charge. |
| 28 | Supply and fixing LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specifiedand directed by Engineer-in-Charge. |
| 29 | Supply and fixing sheet metal enclosure MCB distribution board. Single pole & neutral 240volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link complete all as specifiedand directed by Engineer-in-Charge. |
| 30 | Supply and fixing sheet metal enclosure MCB distribution board. Single pole & neutral 240volts 2 way with IP-43 IK-09 protectioncomplete with appropriate sizecomplete all as specifiedand directed by Engineer-in-Charge. |
| 31 | Supply and fixing in 1100 volts grade heavy duty cable PVC insulated Aluminium staranded conductor , served with inner sheathed PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 01 mtrs apart including 4mm suspention wire one twin core flate/cicular of size 10 sqmm x 2core complete all as specifiedand directed by Engineer-in-Charge. |
| 32 | Supply and fixing in repalcement MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specifiedand directed by Engineer-in-Charge. |
| 33 | All as per item No 32 here-in-before but SPN 16-32 Amps complete all as specifiedand directed by Engineer-in-Charge. |
| 34 | Material & labour for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 complete all as specifiedand directed by Engineer-in-Charge. Note : Result of the earthing should beless then 3 ohms if not achieved the new earthing to be carried out without any extra cost. |
| 35 | Supply, layingtesting and connecting 25 Sqmm 4 Core XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electrical cable with aluminium conductor, 1100 volts grade laid in trenches/ducts/wall or through pipe with suitable size of cable glands, crimping type cable lugs complete all as specified and directed by Engr-in-Charge. |
| 36 | Excavation in trenches in any type of soil, not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundation, laying of cables and getting out complete all as specified & as directed by Engineer-in-charge. |
| 37 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm each layer all as complete all as specified and directed by Engr-in-Charge. |
| 38 | Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 39 | Sand cushioning to under ground cable 8 cm thick layer below the cable and 15cm thick above the cable complete all as specified and directed by Engr-in-Charge. |
| 40 | Brick protection with well burnt sub class ‘B’ brick a butting each other( width wise) across the cable laid in trenchescomplete all as specified and directed by Engr-in-Charge. |
| 41 | Fabrication, installation and testing of LT feeder pillar boxfloor mounted dust/vermin proof outdoor type, powder coated of size 0.60x0.85x0.50 mtr factory fabricated,made out of MS sheet of thickness 3mmmounted on angle iron legs made out of angle iron of size 40x40x6mm withn front & rear opening with locking arrangement, containing bus bar chamber to accommodate 3 phase & 1 neutral copper busbar of size 20 x 10mm drilled with suitable holes for fixing of cables and mounted on epoxy based insulators in horizontal position (stepped manner) in feeder pillar including necessary excavationandPCC work1:2:4 complete all as specified and directed by Engr-in-charge. |
| 42 | Material & labour for tubing GI light grade 50mm bore laid in trenches, ducts, floor for protection of cable,fixed to wall or poles including fixing arrangement all as required and directed by Engineer-in-Charge. |
| 43 | Earthing complete with galvanised steel earth plate electrode 600x600x3.15 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level ) withtop edge of earth plate not less than 1.5 Mtr below normal ground level connected to GI strip 25X4 mm as earth lead by means of bolts, nuts washers and check nutsof steel/GI duly protected with 40 mm bore light grade pipe upto main board , 20mm bore watering pipe light gradewith CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoaldust and common saltin adeqate quantity as recommended by the manufacturer oras directed by the Engr-in-charge all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel withwire mesh complete and all as specified and as directed by Engr-in-charge. |