Implementation Of Scada/Dms Project In Kollam,Thrissur And Kannur(Group A Towns)For Ksebl And Tced In Kerala Under Rdss, Thiruvananthapuram-Kerala

Kerala State Electricity Board-KSEB has published Implementation Of Scada/Dms Project In Kollam,Thrissur And Kannur(Group A Towns)For Ksebl And Tced In Kerala Under Rdss. Submission Date for this Tender is 15-04-2024. CCTV System Tenders in Thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

40679575
Corrigendum : Implementation Of Scada/Dms Project In Kollam,Thrissur And Kannur(Group A Towns)For Ksebl And Tced In Kerala Under Rdss
Open Tender
Indian
Kerala
Thiruvananthapuram
15-04-2024

Tender Details

Implementation Of Scada / Dms Project In Kollam, Thrissur And Kannur ( Group A Towns ) For Ksebl And Tced In Kerala Under Rdss-2 Installation, Testing And Commissioning Cost To Integrate Entire Scada & It ( Relevant To Scada ) Infrastructure 3 Integration With Legacy Applications & Data Migration 4 Training For The Employees 5 Form 2: Scada / Dms Control Centre Cost 6 Server / Workstation Hardware 7 Scada Server 8 Dms Server 9 Oms Server 10 Fep Server With Interface Switches 11 Isr Server 12 Nms Server 13 Dts Server 14 Developmental Server 15 Commnuication Server 16 Web / Directory Server 17 Sms Gateway 18 Workstation With Dual Tft Monitors ( S / S Monitoring ) 19 Workstation With Dual Tft Monitors ( Network Monitoring ) 20 Remote Vdus With One Tft Monitors 21 Developmental Console With One Tft 22 Dts / Workstation Console With Dual Tfts 23 Video Projection System With 2X3 Module Configuration With Each Module At Least 60 Diagonal With Projector 24 Storage & Backup Devices 25 External Raid Mass Storage Device ( For 24 Months Online Backup ) 26 External Dat Drive 27 Switches 28 Layer Ii Switch ( Scada / Dms Lan ) 29 Layer Ii Switch ( Planning & Development System Lan ) 30 Routers 31 Router For Interfacing It System & Scada / Dms Dr Centre 32 Router At Remote Vdu 33 Security System ( Dmz ) 34 Web Server With Load Balancing 35 Mail Server 36 Router 37 Firewall & Network Ids / Ips 38 Layer Ii Switch 39 Other Active Devices 40 Gps Time Synchronisation System 41 Time, Day & Date Digital Displays 42 Printers 43 Color Inkjet Printer 44 B / W Laser Printer 45 Any Other Items Required To Meet Functional / Performance Requirement As Per Mts 46 Sub-Total Form -2 ( Hardware ) 47 Software For Control Centre 48 Scada Software 49 Isr Software 50 Dms Software 51 Oms Software 52 Dts Software 53 Developmental Software 54 Network Management Software 55 Web / Network Security Software ( Incl In Webserver ) 56 Rdbms Package ( Incl In Isr ) 57 Gis Adaptor / Engine For Importing Data From Gis System Under It System 58 Any Other Software To Meet Functional / Performance Requirement As Per Mts 59 Sub-Total Form-2 ( Software ) 60 Mandatory Spares Max 5% Of Form-2 Hardware 61 Mandatory Spares 62 Form 3: Scada / Disaster Replica Recovery Control Cost 63 Server / Workstation Hardware 64 Scada Server 65 Dms Server 66 Oms Server 67 Fep Server With Interface Switches 68 Isr Server 69 Nms Server 70 Dts Server 71 Other Active Devices 72 Developmental Server 73 Commnuication Server 74 Web / Directory Server 75 Sms Gateway 76 Workstation With Dual Tft Monitors ( S / S Monitoring ) 77 Workstation With Dual Tft Monitors ( Network Monitoring ) 78 Developmental Console With One Tft 79 Dts / Workstation Console With Dual Tfts 80 Video Projection System With 2X3 Module Configuration With Each Module At Least 60 Diagonal Withprojector 81 Storage & Backup Devices 82 External Raid Mass Storage Device ( For 24 Months Online Backup ) 83 External Dat Drive 84 Switches 85 Layer Ii Switch ( Scada / Dms Lan ) 86 Layer Ii Switch ( Planning & Development System Lan ) 87 Routers 88 Router For Interfacing It System & Scada / Dms Dr Centre 89 Security System ( Dmz ) 90 Web Server With Load Balancing 91 Mail Server 92 Router 93 Firewall & Network Ips / Ids 94 Layer Ii Switch 95 Other Active Devices 96 Gps Time Synchronisation System 97 Time, Day & Date Digital Displays 98 Printers 99 Color Inkjet Printer 100 B / W Laser Printer 101 Any Other Items Required To Meet Functional / Performance Requirement As Per Mts 102 Sub -Total Form-3 ( Hardware ) 103 Software 104 Scada Software 105 Isr Software 106 Dms Software 107 Dts Software 108 Oms Software 109 Developmental Software 110 Network Management Software 111 Rdbms Package 112 Web / Network Security Software 113 Gis Adaptor / Engine For Importing Data From Gis System Under It System 114 Any Other Items Required To Meet Functional / Performance Requirement As Per Mts 115 Sub-Total ( Form-3 Software ) 116 Mandatory Spares Max 5% Of Form-3 Hardware 117 Mandatory Spares 118 Form 4: Rtu 119 Rtus ( E1 ) 120 Rtu Base Equipment Comprising Panels, Racks, Sub-Racks, Power Supply Modules, Cpu, Interfacing Equipment, Required Converters & All Other Required Items / Accessories Including Complete Wiring For All Modules For Locations Mentioned 121 Multifunction Transducers 122 Contact Multiplying Relays ( Cmrs ) 123 Heavy Duty Relays For Control 124 Dummy Breaker Latching Relays 125 Transformer Transducers 126 Single Tft Pc For Ldms With 2Kva Ups & Vrla Batteries To Give 4Hrs Backup. 127 Any Other Hardware To Meet Functional / Performance Requirement Of Mts 128 Sub - Total ( Hardware ) -Form 4 ( E1 ) 129 Software For Ldms ( E2 ) 130 Ldms Software 131 Any Other Software To Meet Functional / Performance Requirement Of Mts 132 Sub - Total ( Software ) -Form 4 ( E2 ) 133 Test Equipments For Rtu 134 Rtu Database Configuration & Maintenance Software Tool 135 Master Station Cum Rtu Simulator & Protocol Analyser Software Tool 136 Laptop Pc For Above Software Tools Along With Interfacing Hardware Including Hub 137 Sub - Total ( Test Equipment ) -Form 4 138 Mandatory Spares For Rtu 139 5% Of Hardware ( E1 ) 140 Form 5: Frtu 141 Built In Frtus ( F1 ) 142 Mini Pole Mounted Frtu Base Equipment Along With Enclosure Suitable To Work In Open Environment ( Adequate Protection From Water & Dust ) , Racks, Sub-Racks, Power Supply Modules With Power Backup , I / O Modules, Cpu, Interfacing Equipment, Required Converters & All Other Required Items / Accessories Including Complete Wiring For All Modules For Locations Mentioned 143 Contact Multiplying Relays ( Cmrs ) ( May Be Supplied If Required In Future ) 144 Heavy Duty Relays For Control ( May Be Supplied If Required In Future ) 145 Multifunction Transducer ( May Be Supplied If Required In Future ) 146 Any Other Hardware To Meet Functional / Performance Requirement Of Mts 147 Sub-Total ( Hardware ) -Form -5 148 Test Equipments For Frtu 149 Frtu Database Configuration & Maintenance Software Tool 150 Master Station Cum Frtu Simulator & Protocol Analyser Software Tool 151 Laptop Pc For Above Software Tools Along With Interfacing Hardware Including Hub 152 Sub-Total ( Test Equipment ) Form-5 153 Mandatory Spares For Frtu 154 5% Ofhardware ( F1 ) 155 Form 6: Mpls / 4G ( G1 ) 156 Mpls 157 Annual Charges For Min10mbps Links With Rtus 158 Annual Charges For Min 16 Mbps Aggregate Linksat Cc 159 Annual Charges For Min 50 Mbps Aggregate Linksat Drr 160 Annual Charges For Min 2 Mbps Internet Links At Cc 161 Mpls Router 162 Any Other Hardware To Meet Functional / Performance Requirement Of Mts 163 Sub - Total ( G1 ) 164 Gprs ( G2 ) ( 4G ) 165 Annual Charges For Min 64Kbps 4G / 5Gdata For Frtus / Fpi 166 Modems 167 Any Other Hardware To Meet Functional / Performance Requirement Of Mts 168 Sub - Total ( G2 ) 169 Mandatory Spares 5% Of G1, G2 170 Form 7: Ups / Dcps ( Aux Power Supply ) 171 Main Equipments - Control Centre ( H1 ) 172 Ups With Suitable Rating Running In Parallel Redundant Mode 173 Vrla Type Battery Banks For Above Ups For Minimum 30 Min. Backup Duration 174 Sub- Total ( H1 ) 175 Main Equipments - Dr Centre 176 Main Equipments ( H2 ) 177 Ups With Suitable Rating Running In Parallel Redundant Mode 178 Vrla Type Battery Banks For Above Ups For Minimum 30 Min. Backup Duration 179 Sub-Total H2 180 For Rtu / Data Concentrator / Communication Eqpts. ( H3 ) 181 Dc Power Supply ( Dcps ) System Based On Smps 182 Battery Bank For Above Dcps ( Vrla Type ) For Minimum 4 Hrs Backup 183 Sub-Total H3 184 For Frtu ( H4 ) 185 24 / 48 Vdc Power Supply ( Dcps ) System Based On Smps 186 Common For Both Rmu And Frtu ( H5 ) 187 Battery Bank For Above Dcps ( Vrla Type ) For Minimum 4 Hrs Backup ( At Least 26Ah ) 188 Remote Vdu , Ldms Location ( H6 ) 189 Ups ( 2 Kva ) With Vrla Batteries To Give 4 Hrs Back Up 190 Mandatory Spares For Ups 191 5% Of Above H1to H6 192 Form 8: Rmu & Enablers 193 Rmu ( Frtu Integrated ) ( Way Requirement ) ( J1 ) 194 Rmu With Built In Frtu With Racks, Sub-Racks, Power Supply Modules With Power Backup , I / O Modules, Cpu, Hdr, Cmr , Mftinterfacing Equipment, Required Converters & All Other Required Items / Accessories Including Complete Wiring For All Modules For Locations 195 Ctc ( 2Ct ) 196 3C 197 4C 198 2C2t 199 3Ct 200 2C3t 201 3C2t 202 4Ct 203 5C 204 Sub- Total J1 205 Fpi ( J2 ) 206 Communicable 207 Sub-Total J2 208 Mandatory Spares 209 5% Of Above J1 To J2 210 Form 9:Training 211 Operator’S Training 212 Operator For Scada / Dms Control Centre 213 Instructor For Dts 214 Maintenance Training 215 Computer Hardware & System Software 216 Application Software ( Scada / Dms ) 217 Rtu & Frtu 218 Database & Display Development 219 Auxiliary Power Supply 220 Communication System Including Nms

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Nov-2023 Corrigendum 1 Other 29-12-2023
2 23-Nov-2023 Corrigendum 3 Date 29-12-2023
3 23-Nov-2023 Corrigendum 2 Other 29-12-2023
4 05-Dec-2023 corrigendum4 Technical Bid 29-12-2023
5 27-Dec-2023 datecorrigendum Date 09-01-2024
6 08-Jan-2024 Datecorrigendum Date 25-01-2024
7 24-Jan-2024 Corrigendum 7 Date 12-02-2024
8 03-Feb-2024 Corrigendum No.8 Technical Bid 12-02-2024
9 09-Feb-2024 Corrigendum 10 Date 29-02-2024
10 09-Feb-2024 Corrigendum 9 Other 29-02-2024
11 26-Feb-2024 Reply to Bidders queries Other 29-02-2024
12 28-Feb-2024 Corrigendum 11 Date 14-03-2024
13 14-Mar-2024 Date Corrigendum 12 Date 01-04-2024
14 01-Apr-2024 DateCorrigendum Date 15-04-2024

Key Value

Document Fees
INR 17700 /-
EMD
INR 50000000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail