Tender For Supplying, Installation, Testing And Commissioning Of Addressable Fire Detection And Alarm, Vesda Fire Alarm System, Cctv, Access Control System And Rodent Repellent System For The New 4G Equipment Under Ph Ix.2. In Msc At Te Bldg Ambala C, ambala-Haryana

Bharat Sanchar Nigam Limited-BSNL has published Tender For Supplying, Installation, Testing And Commissioning Of Addressable Fire Detection And Alarm, Vesda Fire Alarm System, Cctv, Access Control System And Rodent Repellent System For The New 4G Equipment Under Ph Ix.2. In Msc At Te Bldg Ambala C. Submission Date for this Tender is 20-11-2023. Alarm Systems Tenders in ambala Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

40650505
Corrigendum : Tender For Supplying, Installation, Testing And Commissioning Of Addressable Fire Detection And Alarm, Vesda Fire Alarm System, Cctv, Access Control System And Rodent Repellent System For The New 4G Equipment Under Ph Ix.2. In Msc At Te Bldg Ambala C
Open Tender
Indian
Haryana
ambala
20-11-2023

Tender Details

Supplying, Installation, Testing And Commissioning Of Addressable Fire Detection And Alarm, Vesda Fire Alarm System, Cctv, Access Control System And Rodent Repellent System For The New 4G Equipment Under Ph Ix.2. In Msc At Te Bldg Ambala Cantt.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Nov-2023 Time for completion Technical Bid 20-11-2023

Key Value

Document Fees
INR 590 /-
EMD
INR 23743.0 /-
Tender Value
INR 11.87 Lakhs /-

BOQ Items

Name of Work: Supplying ,Installation , Testing and commissioningofAddressable fire detection and alarm ,VESDA Fire alarm system , CCTV , Access control system and Rodent repellent systemfor the new 4G equipment under Ph IX.2. in MSC at TE Bldg Ambala Cantt.
Sl. No. Item Description
1Addressable Fire Detection System
2Supplying installation testing & commissioning of Micro processor based 2 wire fault tolerant, Networkable type fire alarm/detection 1 loop control panel (having nos. of loops to suit the nos. of fire detectors each loop accessing99 detectors and 99 modules). The panel shall be able to give location ofall fire/fault conditions of addressable units via the address codes.Further, the panel must be able to automatically switch ON /OFF the respective control module when ever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects. The Panel Shall be Steel sheet powder coated, sealed to IP30. The Panel Shall have LED Indicators for indication of various signal The panel shall have a built in power supply and battery charger along with maintenance free 07 AH, 2x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger and conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL as per specifications complete in all respect.(Honeywell Morley/ Notifier/ GST/ Apollo make)
3Supplying installation testing & commissioning of Intelligent Analog Addressable Type Photoelectric Type Smoke Detector Complete with Dual LED, Hard Addressable Having rotary decade Address switches from 01-99, with Mounting Base Complete as required Conforming to BS 5839 Standards and Duly Approved by EN54/LPCB/VDS required to complete the job in all respectApproved Make: Notifier by Honeywell / Edward EST-4, Farenhyt / Johnson Control ( IFC Series) /Nohmi/Ravel/GST/Apollo)
4Supplying installation testing & commissioning of Intelligent Analog Addressable TypeheatDetector Complete with Dual LED, Hard Addressable Having rotary decade Address switches from 01-99, soft programmingwith Mounting Base Complete as required Conforming to BS 5839 Standards and Duly Approved by EN54/LPCB/VDS/UL required to complete the job in all respect ( (Honeywell Morley/ Notifier/ Ravel /GST/Apollo make)
5Supplying installation testing & commissioning of Remote indicator complete with connection etc as required.(Approved Make: Notifier by Honeywell / Edward EST-4, Farenhyt / Johnson Control ( IFC Series) /Nohmi/ Edward/ Ravel/ GST/Apollo)
6Supplying installation testing & commissioning of Intelligent Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully compliant to EN54 having Rotary Decade Switches for Addressing from 01-99 with Back Box for Mounting as required conforming to BS5839 Standards and Duly Approved byEN54/LPCB/VDS as required Approved Make: Notifier by Honeywell / Edward EST-4, Farenhyt / Johnson Control ( IFC Series) /Nohmi/Agni /Devi/ Apollo))
7Supplying installation testing & commissioningof Addressable Type Loop Powered Hootercomplete with Mounting Base as required conforming to BS5839 Standards and Duly Approved byEN54/LPCB/VDS with all labour and material required to complete the job in all respect Approved Make: Notifier by Honeywell / Edward EST-4, Farenhyt / Johnson Control ( IFC Series) /Nohmi/Ravel /GST/Apollo)
8Supplying installation testing & commissioning of Addressable type Fault Isolator for isolating shorted, de-linked and loose circuits between two successive fault isolators with automatic resetting arrangement to be interconnecting to loop cable complete as required conforming to BS5839 Standards and Duly Approved byEN54/LPCB/ VDS/ UL/BSAcomplete as required Approved Make: Notifier by Honeywell / Edward EST-4, Farenhyt / Johnson Control ( IFC Series) /Nohmi/Ravel /GST/Apollo)
9Supply & fixing PVC insulated PVC sheathed strandedarmoured FRLS (ISI Marked) copper conductor cableon surface , including connection etc. complete asrequired
102x1.5 sq mm
114x1.5sq mm
12Supply & fixing of tripod of suitable size with junction box compete with fixing on floor complete as required
13Supply & fixing of MS box painted with White/red colour with sheet for detectors on true ceiling complete as required
14Supplying installation testing & commissioning of control Module ( Input output) for AHU tripping etc complete as requiredDuly Approved byEN54/LPCB/ VDS/ UL/BSAcomplete as requiredApproved Make: Notifier by Honeywell / Edward EST-4, Farenhyt / Johnson Control ( IFC Series) /Nohmi/Ravel /GST/Apollo)
15Supply & fixing of cable gland of suitable size for 2x1.5 sq mm armoured cable for cable termination complete as required.
16SITC OFVESDA SYSTEM
17Supply, installation, testing and commissioning of Laser-Based Absolute Smoke Detection VESDA system Coverage up to 5000 Square-Feet , Single pipe inlet, Maximum pipe lengths: 1 x 50 m (Max. 20 holes per branch), 2 x 30 m (Max. 12 holes per branch), Adjustable Wide sensitivity Range - 0.025 to 20% obs/m, 4 alarm levels ; High efficiency aspirator; Clean air barrier optics protection for the maintenance free sealed autocleaning laser based detection chamber, Easy to replace dual stage filter; 3Nos of inbuilt potential free relay outputs (Pre Alarm, Alarm & fault) Ultrasonic Airflow Sensing, Dual Stage Air Filtration, Instant Recognition Display, Event log up to 2000 events, Multiple Event Logging in separate logs etc. including Power Supply (EN Approved) selectable Input voltage of 110 / 230V AC, output voltage of 24 V DC (nominal), 1.5 Amp DC (minimum) in a suitable sizeenclosure along with 2 nos. 12 V, 12 AH sealed maintenance free battery etc complete as required. (UL listed/ FM/LPCB/VdS/EN 54 approved). (Make: M/S Xtralis VEDSA VLF 500 / System sensor)/(UL 268 listed, FM/LPCB/VdS/EN 54 approved). (VLF 500)
18Supply & installation of Trunk Adaptor for capillary points suitable for VESDA system etc. complete as required.
19Supply & installation of Capillary Sampling Connector for Capillary tubes suitable for VESDA system etc. complete as required.
20Supply and installation of Capillary tube for sample points (5.2mm ID 8mm OD per metre) suitable for VESDA system etc. complete as required.
21Supplying and installation of sampling point for capillary tube end suitable for VESDA system etc. complete as required.
22Supply & installation of sampling point label (RED) suitable for VESDA system etc. complete as required.
23Supplying & Laying ofU-PVC/C-PVC smooth bore aspiration tube of size (21mm Internal Dia and 25mm external dia) suitable for VESDA system with all accessories such as bends, tees, junction fittings including cutting, threading, drilling holes on surface, special jointing, fixing with clamps/clips etc. complete as required. (ASTRAL / AJAY/ASHITRVAD /AK or Similar Superior make)
24SITC of 24 volt operated sounder with flasher complete with connection as required (make Agni)
25Supply & laying of 2 core 1sq mm twisted pair shielded cable for communication( ISI mark)
26Supply & laying of 3core 1sq mm multistrand cable for power
27Providing and fixing of 4Kg capacity portable power type fire extinguisher ISI mark complete with discharge pipe and nozzle etc complete as reqd.)(M/S Lifeguard, OmexFirematics , Stop fire or SS)
28Providing and fixing of 4.5Kg capacity portable CO2 type fire extinguisher ISI mark complete with discharge pipe and nozzle etc complete as reqd.)(M/S Lifeguard, OmexFirematics , Stop fire or SS)
29Clean Agent (Stored Pressure) Type Capacity 2 Kg Fire Extinguisher ISI marked IS: 15683 filled with HFC 236FA / (FK 5-1-12)Clean Agent Gas. Complete with squeeze grip release valve, locking arrangement, pressure gauge, operation manual and bracket. Complete in all respect. Operating Temperature: -30ºC to + 60ºC.
30CCTV
314MP IP Camera : SITC of Indoor bullet 4MP IP IR range upto 50 Mtrs Camera having HD resolution 2560X1440 JPEG/ H.264 /H.265 Low light colour camera as per detailed specifications attached. M/sHanwa (Samsung ) or similar make
3216 Ch. NVR : SITC of 16 Channel Network video recorder suitable for recording resolutions- 1080p to 8MP having 2 SATA HDD interfaces (upto 10 TB capacity per HDD).
33Hard disk Storage : SITC of SATA HDD of 4TB capacity having IPF (Image Perfect firmware) suitable to ensure continues video footage recording 24 hours 7daysforcctvsurveillance.
34PoE Switch : SITC of 24 Port POE L2 unmanaged. ( Make D-Link or Similar Superior make )
35Cat Cable : Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (Dlink/Polycab/amp)
36HDMI Cable:Supply&FixingofHigh-Speed HDMI Cable, Supports Ethernet, 3D, 4K Video( Make- Hi Focus HDMI make Samsung or Similar Superior make )
37Monitor : SITC of LED-backlit 27 inch Monitor with 5 Years Warrantee. (make Samsung)
38Server Rack : Supply & Fixing of Server Rack (9U) of high quality metal sheet 0.8mm (Make-9U or Similar Superior make )
39Supplying and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
40PROXIMITY BASED ACCESS CONTROLSYSTEM
41Access Control Device : Supply & Fixing of ACCESS Control Device having finger prints capacity, Face recognition capacity, DPI optical sensor, Smart Card & PIN Login facility.(Minimum USERS -1000,Event Buffers – 10,000)(make Spectra, ELSS make)
42Smart Cards : Supply & Fixing of Smart Cards, double side card holder and lanyard including printing on lanyard
43EM Lock : Supply & Fixing of Electromagnetic Locks of 600 lbs holding force for single Leaf Suitable For Wooden Door, Glass Door etc. (Make-Mantra/ ESSL or Similar Superior make ).
44Supply & Fixing of emergencyExitSwitchatthe inside of Doors having pushbuttoninapprox.100 mm X 100 mm size PVC box , the frontshouldbe sealed by meansofbreakableglasswiththe neoprene gasket andshouldbedustandvermin proof along with steel hammer and chainas attachment etc. complete as reqd.
45Supplyand Fixing of 12V DC 3 AMP Power Adapter for EM Lock etc. complete as reqd.
46Installation, Testing and Commissioning of Complete Access Control System i/c necessary License / Software required for Access Control Readers / Card / Doors and IntegrationofcompleteIPCCTV& Access Control System as per requirementetc. complete as reqd.
47Supplying and fixing of 25mm dia medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
48Supplying and drawing of 4 pair CAT- 6 cable in existing FRPVC conduit etc. complete as required.
49Supply & installation of Aluminium body Exit push button complete with connection as required.
50Supplying & installation of electromagnetic lock (2 x 600lbs) for double leaf door along with other fixing accessories etc. complete as required.
51Supply & installation of glass break unit for Emergency exit complete with connection as required.
52RODENT REPELLENT SYSTEM
53Supply, installation, testing and commissioning of Rodent Repellent Controller/Console; Single zone and supports 24satellites(JAY make)
54Supply, installation, testing and commissioning ofTransducer or Satellite with blinking LED ( MINIMUM ONE FOR 150 SQ FT AREA)(JAY make)
55Supply & Fixing of Wire 14/40, SWG specially coated wire.
56Supply and laying of ISI grade 25 mm PVC conduit on surface using clip/ saddle complete as required
57Supply & laying of 4 pair CAT 6 copper conductor complete with laying in existing conduit
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail