}

Tender For Dg Sets Supply Installation Testing Commissioning Of Dg Sets , Dg Set , Supply Of ‘Silenttype’Dieselgeneratingsetalong With Having Prime Powerrating Of62.5Kva, 415 Volts At1500rpm,0.8Laggingpowerfactorat415v Suitable For 50 Hz, 3 Phase System, haridwar-Uttarakhand

Development Authority-DA has published Tender For Dg Sets Supply Installation Testing Commissioning Of Dg Sets , Dg Set , Supply Of ‘Silenttype’Dieselgeneratingsetalong With Having Prime Powerrating Of62.5Kva, 415 Volts At1500rpm,0.8Laggingpowerfactorat415v Suitable For 50 Hz, 3 Phase System. Submission Date for this Tender is 28-11-2023. Electrodes Tenders in haridwar Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

40582039
Corrigendum : Tender For Dg Sets Supply Installation Testing Commissioning Of Dg Sets , Dg Set , Supply Of ‘Silenttype’Dieselgeneratingsetalong With Having Prime Powerrating Of62.5Kva, 415 Volts At1500rpm,0.8Laggingpowerfactorat415v Suitable For 50 Hz, 3 Phase System
Open Tender
Indian
Uttarakhand
haridwar
28-11-2023

Tender Details

Dg Sets Supply Installation Testing Commissioning Of Dg Sets , Dg Set , Supply Of ‘Silenttype’Dieselgeneratingsetalong With Having Prime Powerrating Of62.5Kva, 415 Volts At1500rpm, 0.8Laggingpowerfactorat415v Suitable For 50 Hz, 3 Phase System & For 0.85 Load Factor And Consisting Of The Followings:- Also Oem Plants Need To Be Certified Through- Iso- 45001 : 2018, Iso 14001 : 2015, Iso 9001 : 2015 , Bs En 14001:2004 & Ohsas 18001:2007 Dieselengine4strokewatercooled, 4 Cylinder, Electricstart, Of Min 83 Bhp Ormore At 1500 Rpm Suitable For Above Output Of Alternator At 40 Degree C, 50% Rh & At 1000 Meter Msl And Conforming To Bs 5514, Bs649, Is10000, Capableoftaking10%Over Loadingforonehourafter12hoursofcontinuous Operation.Theenginewillbe?Ttedcompletewith All The Required Accessories Including Fuel Tank For 8 Hours Dg Set Operation. Supplying And Making End Termination With Suitable Size Double Compression Nickel Platedbrass Gland And Aluminum Lugsall Complete 02 Nos. Supplying&Layingof20metrepvcinsulated Pvc Sheathed / Xlpe Aluminum Armored Power Cable Of1.1Kvgrade Of 70 Sqmm X 3.5 Core Intheexisting Gi / Dwc Pipe / Open Duct / Open Air Etc Complete As Required. Earthingwithcopperearthplate600mmx 600 Mm X 6 Mm Thick Including Accessories, Andprovidingmasonryenclosurewithcover Plate Havinglockingarrangementand Wateringpipeof2.7Meterlongetc.With Charcoal / Coke And Salt As Required 1 Nos. Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.I.Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washerexcavation Andre-Filling Etc. As Required. 15 Metres. Providing And Fixing 25 Mm X 5 Mm Copper Striponsurfaceorinrecessforconnections Etc. As Required 15 Mtrs. Alternator : Synchronous Alternator Rated At 62.5 Kva, 415 Volts At1500rpm, 3Phase , 50Hz, Ac Supply With 0.8 Lagging Power Factor At 40 Degree C, 50% Rh & At1000 Metermsl. The Alternator Shall Be Havingspdpenclosure, Brushless, Continuous Duty, Self-Excited And Self-Regulated Throughavrconformingtois:4722 / Bs2613 , Supply Of ‘Silenttype’Dieselgeneratingsetalong With Having Prime Powerrating Of125kva, 415 Volts At1500rpm, 0.8Laggingpowerfactorat415v Suitable For 50 Hz, 3 Phase System & For 0.85 Load Factor And Consisting Of The Followings:- Also Oem Plants Need To Becertified Throughiso- 45001 : 2018, Iso 14001 : 2015, Iso 9001 : 2015 , Bs En 14001:2004 & Ohsas 18001:2007 . Dieselengine4stroke , 6 Cylinder, Watercooled, Electricstart, Of Min 156Bhp Ormore Thanwith Electronic Governor At 1500 Rpm Suitable For Above Output Of Alternator At 40 Degree C, 50% Rh & At 1000 Meter Msl And Conforming To Bs 5514, Bs649, Is10000, Capableoftaking10%Over Loadingforonehourafter12hoursofcontinuous Operation.Theenginewillbe?Ttedcompletewith All The Required Accessories Including Fuel Tank For 8 Hours Dg Set Operation. Supplying And Making End Termination With Suitable Size Double Compression Nickel Platedbrass Gland And Aluminum Lugsall Complete02nos. Supplying&Layingof20mtrpvcinsulated Pvc Sheathed / Xlpe Aluminum Armored Power Cable Of1.1Kvgrade Of 120 Sq Mm X 3.5 Core Intheexisting Gi / Dwc Pipe / Open Duct / Open Air Etc Complete As Required. Earthingwithcopperearthplate600mmx 600 Mm X 6 Mm Thick Including Accessories, Andprovidingmasonryenclosurewithcover Plate Havinglockingarrangementand Wateringpipeof2.7Meterlongetc.With Charcoal / Coke And Salt As Required 1Nos. Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.I.Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washerexcavation Andre-Filling Etc. As Required 15 Metres Providing And Fixing 25 Mm X 5 Mm Copper Striponsurfaceorinrecessforconnections Etc. As Required 15Mtrs. Alternator : Synchronous Alternator Rated At 125 Kva, 415 Volts At1500rpm, 3Phase , 50Hz, Ac Supply With 0.8 Lagging Power Factor At 40 Degree C, 50% Rh & At1000 Metermsl. The Alternator Shall Be Havingspdpenclosure, Brushless, Continuous Duty, Self-Excited And Self-Regulated Throughavrconformingtois:4722 / Bs2613 Suitable For Tropical Conditions And With Class- F / H Insulation.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Nov-2023 Technical Bid Technical Bid 28-11-2023

Key Value

Document Fees
INR 1770 /-
EMD
INR 59000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: DG Set
Sl. No. Item Description
1DG Set
2Supply of ‘SilentType’DieselGeneratingsetalong with having Prime PowerRating of62.5KVA, 415 volts at1500RPM,0.8laggingpowerfactorat415V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings:- Also OEM Plants need to be Certified through- ISO- 45001 : 2018, ISO 14001 : 2015, ISO 9001 : 2015 , BS EN 14001:2004 & OHSAS 18001:2007 Dieselengine4strokewatercooled, 4 Cylinder, electricstart, of min 83 BHP ormore at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS649,IS10000,capableoftaking10%over loadingforonehourafter12hoursofcontinuous operation.Theenginewillbe?ttedcompletewith all the required accessories including fuel tank for 8 hours DG set operation. Supplying and making end termination with suitable size double compression nickel platedbrass gland and aluminum lugsall complete 02 nos. Supplying&layingof20MetrePVCinsulated PVC sheathed / XLPE aluminum armored power cable of1.1Kvgrade of 70 sqmm x 3.5 core intheexisting GI/ DWC pipe/ open duct/ open air etc complete as required. Earthingwithcopperearthplate600mmX 600 mm X 6 mm thick including accessories, andprovidingmasonryenclosurewithcover plate havinglockingarrangementand wateringpipeof2.7meterlongetc.with charcoal/ coke and salt as required 1 Nos. Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I.pipe from earth electrode including connection with brass nut, bolt, spring,washerexcavation andre-filling etc. as required. 15 Metres. Providing and fixing 25 mm X 5 mm copper striponsurfaceorinrecessforconnections etc. as required 15 mtrs. Alternator : Synchronous alternator rated at 62.5 KVA, 415 volts at1500RPM,3phase , 50Hz,AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at1000 MeterMSL. The alternator shall be havingSPDPenclosure,brushless, continuous duty, self-excited and self-regulated throughAVRconformingtoIS:4722/BS2613
3Supply of ‘SilentType’DieselGeneratingsetalong with having Prime PowerRating of125KVA, 415 volts at1500RPM,0.8laggingpowerfactorat415V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings:- Also OEM Plants need to beCertified throughISO- 45001 : 2018, ISO 14001 : 2015, ISO 9001 : 2015 , BS EN 14001:2004 & OHSAS 18001:2007 . Dieselengine4stroke ,6 Cylinder,watercooled,electricstart, of min 156BHP ormore thanwith Electronic Governor at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS649,IS10000,capableoftaking10%over loadingforonehourafter12hoursofcontinuous operation.Theenginewillbe?ttedcompletewith all the required accessories including fuel tank for 8 hours DG set operation. Supplying and making end termination with suitable size double compression nickel platedbrass gland and aluminum lugsall complete02nos. Supplying&layingof20mtrPVCinsulated PVC sheathed / XLPE aluminum armored power cable of1.1Kvgrade of 120 sq mm x 3.5 core intheexisting GI/ DWC pipe/ open duct/ open air etc complete as required. Earthingwithcopperearthplate600mmX 600 mm X 6 mm thick including accessories, andprovidingmasonryenclosurewithcover plate havinglockingarrangementand wateringpipeof2.7meterlongetc.with charcoal/ coke and salt as required 1Nos. Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I.pipe from earth electrode including connection with brass nut, bolt, spring,washerexcavation andre-filling etc. as required 15 metres Providing and fixing 25 mm X 5 mm copper striponsurfaceorinrecessforconnections etc. as required 15mtrs. Alternator : Synchronous alternator rated at 125 KVA, 415 volts at1500RPM,3phase , 50Hz,AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at1000 MeterMSL. The alternator shall be havingSPDPenclosure,brushless, continuous duty, self-excited and self-regulated throughAVRconformingtoIS:4722/BS2613 suitable for tropical conditions and with class- F/H insulation.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail