Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-11-2023 | Date Corrigrndum | Date | 29-11-2023 |
| Sl. No. | Item Description |
| 1 | R/M toBuilding (Room tiling,PaintingwithminorrepairworksofQuarterNo.D - 3/4, E- 1/1 , E- 1/4 , E - 3/1 , E - 3/4, E - 9/2, E - 12/4, E - 13/1, E - 14/2, E - 14/4, E - 15/1 , E - 15/2, E - 15/4 atBariniputColony,UKHEP,Bariniput.(PART -1) |
| 2 | Removingoldlimeorcementmortarfromwallsincludingrackingoutjoints12 mmdeepandremovingdebris within50.00 mtrleadincludingalllabour, T & P, Sundries, lead, lift, deliftandlabourcessetccompletein groundfloor and as per the directions of the Engineer in Charge. |
| 3 | Dismantling&removing2.5cmthickA.Sflooringincludingstackingtheusefulmaterialsforreuseandremovingdebriswithin50.00mtrleadincludingalllabour, T & P,sundriesandlabourcessetccompleteingroundfloor and as per the directions of the Engineer in Charge. |
| 4 | DismantlingandremovingR.C.C Columns, slabs, staircaselanding, lintelsincludingstackingtheusefulmaterialsforreuseandremovingthedebriswithin50.00mtrleadincludingalllabour, T&P, sundriesandlabourcessetccompleteingroundfloor and as per the directions of the Engineer in Charge. |
| 5 | Dismantlingbrickorstonemasonryinlimeorcementmortarunder3.00mtrheightincludingstackingtheusefulmaterialsforreuseandremovingthedebriswithin50.00mtrleadincludingalllabour, T & P, sundries, lead, lift,deliftandlabourcessetccompleteingroundfloor and as per the directions of the Engineer in Charge. |
| 6 | Providing and fixing 30mm thick factory made PVC rigid foam panelled door shutter with frame manufactured by M/S Rajashree / Krishna /sintex for equivalent made from M/s tube of 19 gauge thickness, size 19*19mm for styles & 15*15mm for top & bottom rails, covered with heat moulded PVC \"c\" channel of 5mm thick sheet and 30*50mm wide to foam styles and 5mm thick & 75mm wide PVC sheets for top rails and bottom rail and on otherside and 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail panelling of 5mm thick PVC sheet fitted in M.S frames welded/ sealed to the styles and rail with 5*30mm PVC sheet beading on either side and jointed together with solvent cement adhesive etc complete or as per manufacturers specification including fixing frames with 4nos M.S Powder coated butt hinges complete including one 10 inch aluminium aldrop and two aluminium tower bolt of 10 inch and 6inch and aluminium handles all cost, conveyance, loading, unloading, all labour, T&P sundries, and labour cess etc completeingroundfloorand1stfloorand as per the directions of the Engineer in Charge .Unit =Persqm. |
| 7 | 16 mmthickcementplasterincementmortar(1:6)overbrickorstonemasonryincludingcost, conveyance, royalty, lead, lift, delift, alllabour, T & P, sundries, labourcessandcuringetccompleteingroundfloorand as per the directions of the Engineer in Charge. |
| 8 | Brickworkwithflyashbricks23cm x 11 cm x 8 cm sizehavingcrushingstrengthnotlessthan75 kg / sqcmwithdimensionaltolerance±2 %incementmortar(1:6) insuperstructureincludingcost, conveyance, royalty, alllabour, T & P, sundries,labourlessandcuringetccompleteingroundfloorand as per the directions of the Engineer in Charge. |
| 9 | 12mmthickcementplaster(1:4)onR.C.C workincluding admixureofDr.Fixitpidiproof (L /W) + including cost,conveyance,royalty,alllabour,T & P, sundries,labourcessandcuringetccomplete ingroundfloorand1stfloorand as per the directions of the Engineer in Charge. |
| 10 | Finishingwallsurfacewithacrylicwallputtyofapprovedmakeandfinishedsmoothandevensurfacetoreceivepaintingincludingcostofallmaterials ,scaffoldingandstaging,carriage, alllabour,T & P,Sundries,andlabourcessetccomplete ingroundfloorand1stfloorand as per the directions of the Engineer in Charge. |
| 11 | Cementconcrete(1:2:4)forR.C.Cworkswith12 mmsizeHGCBchipsincludingcost, conveyance, royalty, alllabour, T & P, sundries, lead, lift, delift, labourcessandcuringetccomplete ingroundfloorand as per the directions of the Engineer in Charge. |
| 12 | Rigid and smooth centering and shuttering for R.C.C. Works including false works and dismantling them after casting including cost, conveyance, all labour, T&P,sundries, lead, lift, delift and labour cess etc completeand as per the directions of the Engineer in Charge. |
| 13 | R.C.Cfoundation, plinthbandandfootingbasesofcolumns,massconcrete, precastslabetc. |
| 14 | Supplying, fitting and placing uncoated HYSD barTATATISCON Fe-500D / SAILISI reinforcementbarasperdrawing & technicalspecification including cost, conveyance, all labour, T&P, sundries, lead,lift,delift & labour cess etc complete ingroundfloorand as per the directions of the Engineer in Charge. |
| 15 | Providingandfixingvitrifiedtileflooringusingdoublechargedfullyvitrifiedtilesofpremiumgradehavingthicknessof8 cmto10 cmconfirmingtoISI-13756of600mm x 600 mmcoloured/ printedseries( homogeneus ofapprovedquality,ofJohonson / Kajaria / Rack / Somany orequivalentinallfloors&dadosofallheighton20 mmthickbedofcementmortarofmix (1:4) laidinproperslopeandgradientwithscreenedandwashedsharpsandformortarandgroutedwiyhepoxygroutwithrequiredqualitiesofpigmentofapprovedmaketomatchtheshadeofvitrifiedtilesincludingwatering, costofmaterials,alllabour,T & P, sundries,andlabourcessetccomplete ingroundfloorand as per the directions of the Engineer in Charge. |
| 16 | Providingandfixing10 mmthick granite tiles infloors,treads ofsteps, andlandingsusingapprovedshade,qualityandsizeofgraniteslabatallheighton25mmthickbed ofcementmortarofmix( 1: 1)jointedwithneatcementslurry mixedwithpigmentto matchtheshadesofthetilesincludingrubbingandpolishingcompleteinproper slopeandgradientincludingwatering, costofmaterials,alllabour,T & P, sundries,andlabourcessetccomplete ingroundfloorand1stfloorand as per the directions of the Engineer in Charge. |
| 17 | Providingandfixing20 cm x 30 cm / 20 cm x 20 cm special / plain/ printedseriesceramicwalltilesofpremiumgradehavingthickness6.5 mmto6.7 mmconfirmingtoIS 13753 indadosskirtingandrisersofstepson12mm rhickbedofcementplaster(1:3), jointedwithneatcementslurrymixedwithpigmentstomatchtheshadesofthetilesincludingrubbingandpolishingcompleteincludingcost,conveyance, royalty, alllabour, T & P , sundries, lead, lift, delift, labourcessandcuringetccompleteingroundfloorand1stfloorand as per the directions of the Engineer in Charge. |
| 18 | WallpaintingtwocoatswithplasticemulsionpaintofapprovedshadeofAsian /Berger / Shalimarmakeonoldworktogiveanevenshade includingcostofpaint,brush, putty , alllabour,T & P,scaffolding,sundries,carriageandlabourcessetccompleteingroundfloorand1stfloor and as per the directions of the Engineer in Charge. |
| 19 | Dismantling&removingdoors&windowsandventilatorsincludingremovalofframes,hinges, fasteningsandstackingthesameforreuseandremovingthedebriswithin50.00mtrleadandreturningthesameatsectionstoreincludingalllabour,T& P, sundries,labourcessandcuringetccomplete ingroundfloor and as per the directions of the Engineer in Charge. |
| 20 | Removingoldlimeorcementplaster fromwallsincludingrackingoutjoints12mmdeep&removingdebris within50 .00mtrleadincluding alllabour,T & P,sundries,scaffoldingandlabourcessetccompleteingroundfloor and as per the directions of the Engineer in Charge. |
| 21 | Dismantlingbrickorstonemasonryinlimeorcementmortarunder3.00mtrheightincludingstackingtheusefulmaterialsforreuse andremovingthedebriswithin50.00mtrlead includingalllabour,T& P,sundries,labourcessetccompleteingroundfloor and as per the directions of the Engineer in Charge. |
| 22 | Providing and fixing factory made uPVC white colour casement/sliding/overhung window made of extruded profiles of frames and sash will be mitered cut and fusion welded at all corners including drilling of holes for fixing hard wares and drainage of waters etc making arrangement for fixing hardwares EPDM gasket 1.2+/- 0.2 mm thick galvanised steel profile to be inserted in required profile frame will be fixed to the wall with 8 x 100 mm long fasterners all complete as per direction of Engineer in charge of approved brand and design (Fenesta/LG hyusen/equivalent) Sliding wind or with two/three track (2/4 shutter) sliding frame 67/52 mm with sliding glazing bead 35 mmx18mm with sliding interlock for window (one vertical in each shutter 45.5x28mm with 5mm glass of approved quality and with touch lock, steel roller 8 nos, crescent lock 2 nos(white powder coated) all complete as per direction of Engineer in charge.(measurement to be taken as Sqm) |
| 23 | Providing & fixing Wood plastic Composite section work framed and fixed (wrought & putup) in trusses, purlins, frames of doors & windows including drilling holes 16 mm dia in window chaukath and fixing 16 mm dia rod as window grating, ventilators,beams including two coats of hot bitumen applied to rear face of frame in contact with masonry or concrete surface and fixed the same in position with six numbers of MS hold fast of 40mm x 5mm embedded in cement concrete blocks (0.23 x 0.15 x 0.15)mtr with cement concrete (1:2:4) using 12mm HGCB chips including all cost of materials,labour, T & P, sundries,labour cess and curing etc complete and as per the directions of the Engineer in Charge. |
| 24 | Providing and fixing30mmthickfactory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers wood powder/rice husk / wheat husk)and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hingesof required size with necessary full body threaded star headed counter sunk S.S screws all as per direction of Engineer-in-charge. |
| 25 | Providing M.S grillsmadeoutofM.Sangleframeofcrosssection40mm x 40mm x 5mm,4 nosoffixingclampsof0.20 mtr longeach ofsameanglesection,10 numbersof 12sqmm MSbarsof1.50mtrlong eachashorizontal barsand4numbersof10 sqmm MSbarsasvertical members @ 1.20mtrlong each, primingtheMSgrill withredoxideprimerandpaintingtwocoatswithanyapprovedenamelpaint&fixingthesamein position withcementconcrete(1:2:4)with12mm HGCB chipsfor4nosofclampgroovesetccomplete including allcostof materials,labour,T & P,sundries,fabricationcharges, fixingcharges&labourcessetccomplete and as per the directions of the Engineer in Charge. |
| 26 | Cementconcrete (1:2:4) with12mmsizeHGCBchipsincludingcost,conveyance,royalty,alllabour, T & P, sundries, lead,lift,delift,labourcessandcuringetc.complete ingroundfloorand1stfloor and as per the directions of the Engineer in Charge. |
| 27 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles and as per the directions of the Engineer in Charge. |
| 28 | Primingonecoat withredoxideprimer includingcostofprimer, all labour,T & P, sundries,scaffolding ,brush,conveyanceandlabourcessetccompleteingroundfloorand1stfloor and as per the directions of the Engineer in Charge. |
| 29 | PaintingtwocoatswithanyapprovedenamelpaintofAsian/ Shalimar/ Bergermakeincludingcostofpaint,alllabour,conveyance, T&P,sundries,scaffolding,brushandlabourcessetccompleteingroundfloorand1stfloor and as per the directions of the Engineer in Charge. |
| 30 | Providing andfixing30cm x 30cm / 40cm x 40cmspecialplain / printedseriesceramic antiskid floor tilesofpremiumgradehavingthickness7mmto8mmconfirmingtoIS 13755infloors, treadsorstepsandlandingson 25 mmthickbed ofcementmortar(1:4)jointedwithneatcementslurrymixedwithpigmenttomatchtheshadesofthetilesincludingrubbingandpolishingcompleteincludingcost oftiles, alllabour,T & P, sundries, allothermaterials,conveyance, royalty,lead,lift, delift, labour cessandcuringetccomplete ingroundfloorand1stfloor and as per the directions of the Engineer in Charge. |
| 31 | Providing,fitting and fixingconcretechequered tilesin floorsofsize 30cm x 30cm x 2.5cm oflocalmake laidon20mmthickcementmortar(1:4)andfillingthejoints with whitecementofapprovedqualityincluding costofallmaterials, labour,T & P,sundries, lead,lift,delift,carriageandlabourcess etc complete and as per the directions of the Engineer in Charge. |
| 32 | Hoisting joists & trusses & placing in position including all labour, T & and labour cess etc complete in ground floor and as per the directions of the Engineer in Charge. |
| 33 | Electrical Re-installation to the Quarter No. E-1/1, E-1/4, E-3/1, E-3/4, E-9/2, E-12/4, E-13/1, E-14/2, E-14/4, E-15/1, E-15/2, E-15/4 at Bariniput Colony, UKHEP, Bariniput. (PART-2) |
| 34 | LIGHT POINT: Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor with ISI marked with 20mm dia non-metalic PVC flexible conduit with 5 Amp, 250V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover with suitable size, MS box with 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge. (Make of wire Finolex/ L&T/ Anchor/ Havels/ V Guard) (A.R.2010, Item No.1.1.1, Page.1) |
| 35 | a) Group-A |
| 36 | b) Group-B |
| 37 | c) Group-C |
| 38 | FAN POINT: Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor with ISI marked with 20mm dia non-metalic PVC flexible conduit with 5 Amp, 250V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover with suitable size, MS box with 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge. (Make of wire Finolex/ L&T/ Anchor/ Havels/ V Guard) (A.R.2010, Item No.1.1.1, Page.1) |
| 39 | a) Group-A |
| 40 | b) Group-B |
| 41 | c) Group-C |
| 42 | CALL BELL POINT: Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor with ISI marked with 20mm dia non-metalic PVC flexible conduit with 5 Amp, 250V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover with suitable size, MS box with 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge. (Make of wire Finolex/ L&T/ Anchor/ Havels/ V Guard) (A.R.2010, Item No.1.1.1, Page.1) |
| 43 | c) Group-C |
| 44 | Recessed wiring to submain in 2 X 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in 20mm dia non-metalic heavy duty PVC flexible conduit 1.6mm thick alongwith 1 X 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required. ( Make- Finolex/ L&T/ Anchor/ Havels/ V Guard) (AR-2010, Item No.1.8.1, Page-12) |
| 45 | Recessed wiring to submain in 2 X 2.5 Sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in 20mm dia non-metalic heavy duty PVC flexible conduit 1.6mm thick alongwith 1 X 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required. (Make- Finolex/ L&T/ Anchor/ Havels/ V Guard) (AR-2010, Item No.1.8.2, Page-12) |
| 46 | Recessed wiring to submain in 2 x 4 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metalic PVC flexible conduit 1.6mm thick alongwith 1 X 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor for loop earthing as required. ( Make- Finolex/ L&T/ Anchor/ Havels/ V Guard) (AR-2010, Item No.1.8.3, Page-13) |
| 47 | Supply & fixing of 5 pin 5/6 Amp modular socket outlet on the existing switch box/ cover including connections as required (A.R.2010, Item No.1.25.4, Page.122) |
| 48 | Supply & fixing of 5 pin 5/6 Amp modular switch on the existing switch box/ cover including connections as required (A.R.2010, Item No.1.25.4, Page.122) |
| 49 | Supply & fixing of 5 Amp modular Bell Push ISI Marked switch on the existing switch box/ cover including connections as required (A.R.2010, Item No.1.25.4, Page.122) |
| 50 | Extension Board 5/6 Amp: Supply & fixing of modular base & cover for 6 module on surface or in recess with suitable size of phenolic laminated sheet cover infront including providing and fixing 5 pin 5/6 amps modular Socket outlet and 5/6 amps modular switch, connection, painting etc as required. (A.R.2010, Item No.1.26, Page.126) |
| 51 | FOR POWER PLUG/ 32AMP MCB/ DP SWITCH/DP MCB: Supply & fixing of 16/18 SWG metal box of size 200mm x 150mm x 75mm deep (nominal size) on surface/ recess with suitable size of phenolic laminated sheet cover infront including cutting te wall and making good the same in case of recessed conduit as required (A.R.2010, Item No.1.24.8, Page.110) |
| 52 | FOR GYSER POINT: Supply & fixing of modular base & cover for 4 module on surface or in recess with suitable size of phenolic laminated sheet cover infront including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. (A.R.2010, Item No.1.27, Page.127) |
| 53 | FOR AC POINT: Supply & fixing of 32 amp DP MCB on the exisitng switch box/ cover including connections as required (AR- 2010, Item No. 1.25.5, Page.123) |
| 54 | FOR KITCHEN ROOM:Supply & fixing of 32 amp DP switch on the exisitng switch box/ cover including connections as required (AR- 2010, Item No. 1.25.5, Page.123) |
| 55 | Supply and fixing of moduar base angle holder of ISI marked, including connection etc as required. (AR-2010, Item No-1.29, Page-129) |
| 56 | Installation, testing & commissioning of pre-wired fluorescent fitting/ compact fluorescent fitting of all sizes complete with all accessories and tube etc directly on ceiling wall, including connection with 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor and earthing as required. (AR-2010, Item No.1.33, Page-133) |
| 57 | Installation, testing & commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor and earthing as required. (AR-2010, Item No.1.36, Page-136) |
| 58 | Installation, testing & commissioning of 10 Amp Step Type ceiling fan Regulator (make Anchore / Roma) in the existing switch box including connection with 1.5 sqmm FR PVC insulated single core multi stand copper conductor, earthing the regulator as required. (AR-2010, Item No.1.38, Page-138) |
| 59 | BOARD FOR BDB BOX: Supply & fixing of 4 Way single pole Double Door MCB DB with sheet steel enclosure, distribution board, on surface/ recess, complete with tinned copper bar, neutral bus bar, earth bar, din bar, ditachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required. (But without MCB/ RCCB/ ISOLATOR) (AR-2010, Item No. 2.3.5, Page-170) |
| 60 | BDB BOX: Supply & fixing of 8 Way single pole Double Door MCB DB with sheet steel enclosure, distribution board, on surface/ recess, complete with tinned copper bar, neutral bus bar, earth bar, din bar, ditachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required. (But without MCB/ RCCB/ ISOLATOR) (AR-2010, Item No. 2.3.6, Page-171) |
| 61 | BOARD FOR MAIN SWITCH: Supply & fixing of 16/ 18 SWG metal box of sizes 250mm X 300mm X 100mm deep on surface/ recess with suitable size of phenolic laminated sheet cover infront including cutting the wall and making good the same in case of recessed conduit as required. (AR-2010, Item No.1.24.13, Page-115) |
| 62 | MAIN SWITCH: Supply, installation, testing and commissioning of 32 Amp DP Main switches (IS 13940 Part-3, 1993) on the existing surface/ wall mounting and complete with HRC fuse links, interconnections, earthing etc as required as per direction of Engineer in Charge. Make (SEIMENS/ HPL/ ANCHOR/ L&T/ HAVELS/ C&S/ RK. (AR-2010, Item No.2.15.1, Page-208) |
| 63 | Supply & fixing of 6 Amp to 32 Amp rating 240V \"B\" series miniature circuit breaker suitable for lighting and other loads of single pole and neutral in the existing MCB DB ISI marked complete with connections, testing and commissioning as required. (AR-2010, Item No.2.6.2, Page-187) |
| 64 | Earthing with G.I. Earth pipe 3 mtr long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required. (AR-2010, Item No.3.2, Page-219) |
| 65 | 6 sqmm PVC insulated Aluminium black flat twin core wire |
| 66 | G.I. wire 10 SWG as tension wire for service wire |
| 67 | 25mm dia G.I. pipe medium class 1.6mm thick |
| 68 | G.I. Socket & Bend |
| 69 | Labour Charges for fixing Service Pipe with cement concrete with wall touchup |
| 70 | Electrical Re-installation to the quarter No- D-(DS)-3/4 at Bariniput Colony, UKHEP, Bariniput (PART-3) |
| 71 | LIGHT POINT: Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor with ISI marked with 20mm dia non-metalic PVC flexible conduit with 5 Amp, 250V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover with suitable size, MS box with 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge. (Make of wire Fiolex/ L&T/ Anchor/ Havels/ V Guard) (A.R.2010, Item No.1.1.1, Page.1) |
| 72 | a) Group-A |
| 73 | b) Group-B |
| 74 | c) Group-C |
| 75 | FAN POINT: Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor with ISI marked with 20mm dia non-metalic PVC flexible conduit with 5 Amp, 250V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover with suitable size, MS box with 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge. (Make of wire Finolex/ L&T/ Anchor/ Havels/ V Guard) (A.R.2010, Item No.1.1.1, Page.1) |
| 76 | b) Group-B |
| 77 | CALL BELL POINT: Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor with ISI marked with 20mm dia non-metalic PVC flexible conduit with 5 Amp, 250V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover with suitable size, MS box with 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge. (Make of wire Finolex/ L&T/ Anchor/ Havels/ V Guard) (A.R.2010, Item No.1.1.1, Page.1) |
| 78 | c) Group-C |
| 79 | Recessed wiring to submain in 2 X 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in 20mm dia non-metalic heavy duty PVC flexible conduit 1.6mm thick alongwith 1 X 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required. ( Make- Finolex/ L&T/ Anchor/ Havels/ V Guard) (AR-2010, Item No.1.8.1, Page-12) |
| 80 | Recessed wiring to submain in 2 X 2.5 Sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in 20mm dia non-metallic heavy duty PVC flexible conduit 1.6mm thick alongwith 1 X 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required. (Make- Finolex/ L&T/ Anchor/ Havels/ V Guard) (AR-2010, Item No.1.8.2, Page-12) |
| 81 | Recessed wiring to submain in 2 x 4 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit 1.6mm thick alongwith 1 X 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor for loop earthing as required. ( Make- Finolex/ L&T/ Anchor/ Havels/ V Guard) (AR-2010, Item No.1.8.3, Page-13) |
| 82 | Supply & fixing of 5 pin 5/6 Amp modular socket outlet on the existing switch box/ cover including connectios as required (A.R.2010, Item No.1.25.4, Page.122) |
| 83 | Supply & fixing of 5 pin 5/6 Amp modular switch on the existing switch box/ cover including connections as required (A.R.2010, Item No.1.25.4, Page.122) |
| 84 | Supply & fixing of 5 Amp modular Bell Push ISI Marked switch on the existing switch box/ cover including connections as required (A.R.2010, Item No.1.25.4, Page.122) |
| 85 | Extension Board 5/6 Amp: Supply & fixing of modular base & cover for 6 module on surface or in recess with suitable size of phenolic laminated sheet cover infront including providing and fixing 5 pin 5/6 amps modular Socket outlet and 5/6 amps modular switch, connection, painting etc as required. (A.R.2010, Item No.1.26, Page.126) |
| 86 | FOR POWER PLUG/ 32AMP DP MCB/ DP SWITCH: Supply & fixing of 16/18 SWG metal box of size 200mm x 150mm x 75mm deep (nominal size) on surface/ recess with suitable size of phenolic laminated sheet cover infront including cutting the wall and making good the same in case of recessed conduit as required (A.R.2010, Item No.1.24.8, Page.110) |
| 87 | FOR GYSER POINT: Supply & fixing of modular base & cover for 4 module on surface or in recess with suitable size of phenolic laminated sheet cover infront including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. (A.R.2010, Item No.1.27, Page.127) |
| 88 | FOR AC POINT: Supply & fixing of 32 amp DP MCB on the exisitng switch box/ cover including connections as required (AR- 2010, Item No. 1.25.5, Page.123) |
| 89 | FOR KITCHEN ROOM:Supply & fixing of 32 amp DP switch on the exisitng switch box/ cover including connections as required (AR- 2010, Item No. 1.25.5, Page.123) |
| 90 | Supply and fixing of modular base angle holder of ISI marked, including connection etc as required. (AR-2010, Item No-1.29, Page-129) |
| 91 | Installation, testing & commissioning of pre-wired fluorescent fitting/ compact fluorescent fitting of all sizes complete with all accessories and tube etc directly on ceiling wall, including connection with 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor and earthing as required. (AR-2010, Item No.1.33, Page-133) |
| 92 | Installation, testing & commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 Sq.mm. FR PVC insulated single core multistrand copper conductor and earthing as required. (AR-2010, Item No.1.36, Page-136) |
| 93 | Installation, testing & commissioning of 10 Amp Step Type ceiling fan Regulator (make Anchore / Roma) in the existing switch box including connection with 1.5 sqmm FR PVC insulated single core multi stand copper conductor, earthing the regulator as required. (AR-2010, Item No.1.38, Page-138) |
| 94 | BOARD FOR BDB BOX: Supply & fixing of 4 Way single pole Double Door MCB DB with sheet steel enclosure, distribution board, on surface/ recess, complete with tinned copper bar, neutral bus bar, earth bar, din bar, ditachable gland plate, iterconnection, phosphate and powder painted including earthing etc. as required. (But without MCB/ RCCB/ ISOLATOR) (AR-2010, Item No. 2.3.5, Page-170) |
| 95 | BDB BOX: Supply & fixing of 8 Way single pole Double Door MCB DB with sheet steel enclosure, distribution board, on surface/ recess, complete with tinned copper bar, neutral bus bar, earth bar, din bar, ditachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required. (But without MCB/ RCCB/ ISOLATOR) (AR-2010, Item No. 2.3.6, Page-171) |
| 96 | BOARD FOR MAIN SWITCH: Supply & fixing of 16/ 18 SWG metal box of sizes 250mm X 300mm X 100mm deep on surface/ recess with suitable size of phenolic laminated sheet cover infront including cutting the wall and making good the same in case of recessed conduit as required. (AR-2010, Item No.1.24.13, Page-115) |
| 97 | MAIN SWITCH: Supply, installation, testing and commissioning of 32 Amp DP Main switches (IS 13940 Part-3, 1993) on the existing surface/ wall mounting and complete with HRC fuse links, interconnections, earthing etc as required as per direction of Engineer in Charge. Make (SEIMENS/ HPL/ ANCHOR/ L&T/ HAVELS/ C&S/ RK. (AR-2010, Item No.2.15.1, Page-208) |
| 98 | Supply & fixing of 6 Amp to 32 Amp rating 240V \"B\" series miniature circuit breaker suitable for lighting and other loads of single pole and neutral in the existing MCB DB ISI marked complete with connections, testing and commissioning as required. (AR-2010, Item No.2.6.2, Page-187) |
| 99 | Earthing with G.I. Earth pipe 3 mtr long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required. (AR-2010, Item No.3.2, Page-219) |
| 100 | 6 sqmm PVC insulated Alluminium black flat twin core wire |
| 101 | G.I. wire 10 SWG as tension wire for service wire |
| 102 | 25mm dia G.I. pipe medium class 1.6mm thick |
| 103 | G.I. Socket & Bend |
| 104 | Labour Charges for fixing Service Pipe with cement concrete with wall touchup |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy