Tender For Maintenance And Upgradation Of Electrical System For The Variousbuildings And Providing Round The Clock Operation For Substation And Ac Plant Attraining School Building, Barc, Anushaktinagar, Mumbai., Mumbai Suburban-Maharashtra

Bhabha Atomic Research Centre-BARC has published Tender For Maintenance And Upgradation Of Electrical System For The Variousbuildings And Providing Round The Clock Operation For Substation And Ac Plant Attraining School Building, Barc, Anushaktinagar, Mumbai.. Submission Date for this Tender is 01-12-2023. HVAC Tenders in Mumbai Suburban Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

40554447
Tender For Maintenance And Upgradation Of Electrical System For The Variousbuildings And Providing Round The Clock Operation For Substation And Ac Plant Attraining School Building, Barc, Anushaktinagar, Mumbai.
Open Tender
Indian
Maharashtra
Mumbai Suburban
01-12-2023

Tender Details

Maintenance And Upgradation Of Electrical System For The Variousbuildings And Providing Round The Clock Operation For Substation And Ac Plant Attraining School Building, Barc, Anushaktinagar, Mumbai.

Key Value

Document Fees
Refer document
EMD
INR 328000.0 /-
Tender Value
INR 1.64 Crore /-

BOQ Items

Name of Work: Maintenance and Upgradation of electrical system for the variousbuildings and providing round the clock operation for Substation and AC plant atTraining School Building, BARC, Anushaktinagar, Mumbai.
Sl. No. Item Description
1Round the clock operation of Electrical HT< system and HVAC as perTSS-1.
2Half yearly maintenance of all type of fans (3 x 300 Nos.=900Nos) as perTSS-2.
3Rewinding of all type of fans as perTSS-3.
4Supply, installation,testing and commissioning (SITC) of 230Volt, 1200mm sweep, BLDC Ceiling fan with regulator as perTSS-4.
5SITC of 230Volt, 200 mm sweep, plastic body exhaust fan with louvers as perTSS-5.
6SITC of 230 Volt, 300 mm sweep, plastic body wall mounted fan as perTSS-6.
7Half yearly maintenance of all type of lighting fixture (3 X200Nos=300Nos) as perTSS-7.
8Maintenance ofpower points and lighting switch box as perTSS-8.
9SITC of LED, 105W, Outdoor Flood Lighting Fixture as perTSS-9.
10SITC of LED, 20W Indoor Batten Type Lighting Fixture as perTSS-10.
11SITC of LED, 36 W Outdoor street Lighting Fixture as perTSS-11.
12SITC of LED, 10W, 2ft, Indoor Batten Type Lighting Fixture as perTSS-12.
13SITC of LED, 30 W, 2ftX2ft Recess Type Lighting Fixture as perTSS-13.
14SITC of LED, 18W, 1ftX1ft Reccess type Lighting Fixture as perTSS-14.
15SITC of LED 9 W round shaped recess type, cut out size 4.5 inch as per TSS-15.
16SITC of LEDSTRIP >/=6.5W/M &120 LED/Malong with driver for each 5M as perTSS-16.
17SITC of Driver for LED 120W Lighting Fixture as perTSS-17.
18SITC of Driver for LED40W Lighting Fixture as perTSS-18.
19SITC of Driver for LED 20-22 W Lighting Fixture as perTSS-19.
20SITC of SMPS Driver for LED 20W strip/Lighting Fixture as perTSS-20.
21Maintenance of LT Motors 3 H.P. to 5 H.P.(2 times eachX9 Nos motors = 18Nos) as perTSS-21.
22Maintenance of LT Motors 7.5 H. P. to 12.5 H.P. (2 times each X8Nos motors = 16Nos) as perTSS-21.
23Maintenance of LT Motors 15H.P. to 20 H.P. (2 times eachX4 Nos motors= 8Nos) as perTSS-21..
24Maintenance of LT Motors 50 H.P. (2 times each X6 Nos motors = 12Nos) as perTSS-21..
25Overhauling of LT Motors 3 H.P. to 5 H.P.(1timeX9 Nos = 9Nos) as perTSS-22.
26Overhauling of LT Motors 7.5 H. P. to 12.5 H.P. (1timeX8 Nos = 8Nos) as perTSS-22.
27Overhauling of LT Motors 15H.P. to 20 H.P. (1timeX4 Nos = 4Nos) as perTSS-22.
28Overhauling of LT Motors50 H.P. (1timeX6 Nos = 6Nos) as perTSS-22.
29Rewinding of 3Phase, LT motors 3 H.P. to 5 H.P. as perTSS-23.
30Rewinding of 3Phase, LT motors 7.5 H. P. to 12.5 H.P. as perTSS-23.
31Rewinding of 3Phase, LT motors 15H.P. to 20 H.P. as perTSS-23.
32Rewinding of 3Phase, LT motors 50 H.P.as perTSS-23.
33SITC of Terminal plate with stud of LT Motor for 3 H.P. to 5 H.P. as perTSS-24.
34SITC of Terminal plate with stud of LT Motor 7.5 H. P. to 12.5 H.P. as perTSS-24.
35SITC of Terminal plate with stud of LT Motor 15H.P. to 20 H.P. as perTSS-24.
36SITC of Terminal plate with stud of LT Motor 50 H.P. as perTSS-24.
37SITC of LT Motor of 3 H.P. to 5 H.P. as perTSS-25.
38SITC of LT Motor of 7.5 H. P. to 12.5 H.P. as perTSS-25.
39Repair of end shield & Bearing housing of LT Motor of 15H.P. to 20 H.P. as perTSS-25.
40Repair of end shield & Bearing housing of LT Motor of 50 H.P. as perTSS-25.
41Maintenance of D.O.LMotor Starter (3times x18Nos=54 Nos.)as perTSS-26.
42Maintenance of Star Delta Motor Starter (3times x 10Nos=30Nos) as perTSS-26.
43SITC of power contractor for star-delta starters for 3phase LT motors of15H.P. to 20 H.P. as perTSS-27.
44SITC of power contractor for star-delta starters for 3phase LT motors of50 H.P. as perTSS-27.
45SITC ofOL Relay ofrange of various sizesfrom 5 to 25 Amps as perTSS-28
46SITC of OL Relay range of various sizes above 25 Amps up to 45 Amps as perTSS-28
47SITC ofElectronicTimerfor Star Detla Starters as perTSS-28
48SITC ofPower contactor"s contactkit. as perTSS28
49SITC of"NO" & "NC" Add on block for Contactor of Siemens make. as perTSS28
50SITC of power contractor of capacitor switching grade for 3phase 25kVAR capacitor bank as perTSS-29
51Maintenance of 11 KV, HT Switchgear Panel - 1Set with5 Breakers-1set (2 times x 1Set =2Set) as perTSS-30.
52Maintenance of LT, Main panel with 3 ACB and 16 MCCB-1set, (2times x1Set=2Set) as perTSS31.
53Maintenance of LT, PCC with 1 ACB and 12 MCCB-1 Set (2timesx1Set=2Set) as perTSS-31.
54Maintenance of LT, PCC, MCC & APFC Panel -30 Nos (2 times x 30 Nos=60Nos) as perTSS-32.
55Maintenance of 11kV/433V, 1250 kVA Transformer including oil filteration(2 times x 2Nos=4Nos) as perTSS-33.
56Maintenance of Distribution Boards -230 Nos.(2x115Nos.) as perTSS-34.
57Maintenance of Rising Mains (75Mtrs) as perTSS-35.
58Maintenance of Lightning Arrester-24 Nos.(1x24 Nos) as perTSS-36.
59Maintenance of Earthing Station -24 Nos. (1x24Nos) as perTSS-37.
60Maintenance of SFU/ MCCB etc.-30 Nos. (1x30Nos) as perTSS-38.
61Maintenance of 6 kVA UPS with battery bankat HBNI -1 Set (3 x 1 Set) as perTSS-39.
62Maintenance of Battery Charger with battery bank at Sub staion -1Set(3 x 1Set) as perTSS-39.
63Battery bank C-10 capacity test of 180V, 26AH, battery banks meant for 6 kVA UPS at HBNI library - 1 Set,(1x1 Set) as perTSS-40.
64Battery bank C-10 capacity test of 110V, 100 AH Battery bank at sub staion -1No(1x1Set.) as perTSS-40.
65SITC of spare of Battery charger as perTSS-41.
66SITC ofPrinter head and display for HP Office jet pro 8600 printer as perTSS-42.
67Servicingof EV scooter with supply of sparesas perTSS-43.
68Maintenance of fire Fire Alarm System at TSH, NBH and NTS-1 Set (6 X 1set) as perTSS-44.
69SITC of Multisensor detector (SIGA-PHS) with base (SIGA-SB) for fire alarm system EST3 as perTSS-45.
70(SITC) of Power Supply card of MFAP for existing fire alarm system of GE/Edward make EST3 Model as per TSS-45
71SITC of Loop Card for existing fire alarm system of GE/Edward make EST3 Model as per TSS-46
72SITC Multisensor detector base(SIGA-SB) for existing fire alarm system of GE/Edward make EST3 Model as perTSS-45.
73SITC of Manual call point (MCP) for existing fire alarm system of GE/Edward make EST3 Model as perTSS-45
74SITC of 12V, 7AH VRLA battery for existing fire alarm system of GE/Edward make EST3 Model as perTSS-45
75Rectification/Attendingfault in existing telephone and its network on complaints by user as per specification as perTSS-46.
76SITC of3 kW,1 litrecapacity instant Geyser as perTSS-47.
77SITC of3 kW, Heating Coil for geyser with gasket,"O" ring etc. as perTSS-48.
78SITC ofThermostat (0 to 80 degree centigrate or above) for geyser as perTSS-49.
79SITC of Neon Indicator Lamp for geyser as perTSS-50.
80SITC of 230 volt, 5Amp, 3 Pin Top as perTSS-51.
81SITC of 230 volt, 15Amp, 3 Pin Top as perTSS-51.
82SITC of 20A Metal clad Socket withmetal clad top as perTSS-51.
83SITC of 6A, SP Switch ROMA/Kalkias per TSS-51.
84SITC of 20A, SP Switch ROMA as perTSS-51.
85SITC of 6A, SP Switch Legrand as perTSS-51.
86SITC of 20A, SP Switch Legrand as per TSS-51.
87SITC of 10A,Socket ROMA/Kalki as perTSS-51.
88SITC of 20 & 10 Amp Twin SocketROMA as per TSS-51.
89SITC of 10A,Socket Legrand as perTSS-51.
90SITC of 20 & 10 Amp Twin SocketLegrand as perTSS-51.
91SITC of 100 watt,1 module step regulator ROMA as perTSS-51.
92SITC of 10A, Bell Push -2 module switch ROMA as perTSS-51.
93SITC of RJ 45 Data Outlet socketcat-6- 1 Module Legrand as per TSS-51.
94SITC of 20A Metal clad Socket & (20A to 32A) SP MCB in MS Box as peras perTSS-51.
95SITC ofSurface PVC Modular Boxes with Cover Plate 2 Module as perTSS-51.
96SITC of Surface PVC Modular Boxes with Cover Plate 3 Module as perTSS-51.
97SITC ofFly killer flu recent blue coloured flurent tube as perTSS-51.
98SITC of Lamp for 125 watt HPMV Fixture as perTSS51.
99SITC ofCapacitor suitablefor Ceiling/Exhaust /Wall fans etc. as perTSS-51.
100SITC of1.0 Sqmm copper wire, FRLS insulated as perTSS-52.
101SITC of2.5 sq mm copper wire, FRLS insulated as perTSS-52.
102SITC of 4 sq mm copperwire, FRLS insulated as perTSS-52.
103SITC of Cat - 6 cable as perTSS-52.
104SITC of PVC Trunking 80mm X 50mmalong with cover and separator as perTSS-53.
105SITC of PVC 32 X 12.5mm casing capping as perTSS-54..
106SITC of 240V, (40 to 63) Amps, 30mA DP RCCB as perTSS-55.
107SITC of 240V, (20 to 32) Amps, DP MCB as perTSS-55.
108SITC of 240V, 20Amps compact SP MCB (Roma) as perTSS-55.
109SITC of 240V, 20Amp, 10 KA, "C"CurveSP MCB as perTSS-55.
110SITC of 415V, 63 Amp , 10 KA, "C"Curve,TP/FP, MCB as perTSS-55.
111SITC of Powder coated MS boxes for (DP to FP) MCB enclosure as per TSS-55.
112SITC of Digital Timer Switch for Street Lighting as perTSS-56.
113SITC of Power Contactor 20A, AC-1 Duty with 1NO+1NC as perTSS-57.
114SITC of 25 Sqmm copper lug as perTSS-58.
115SITC of MS item fabricated out of angle/channel/Sheet etc. for cable/structure/ pipe / duct supports etc. as perTSS-59.
116SITC of Painting of metallic surface as perTSS-60.
117SITC of End Termination of 1.1 kV cable Upto 4C X 6 sq mm as perTSS-61.
118SITC of End Termination of 1.1 kV cable4C / 3.5C X (16sq mm to 25 sq mm) as perTSS-61..
119SITC of End Termination of 1.1 kV cable 3.5 C X 35 sq.mm as perTSS-61.
120SITC of End Termination of 1.1 kV cable 3.5 C X 50 sq.mm as perTSS-61.
121SITC of End Termination of 1.1 kV cable 3.5 C X 70 sq. mm as per TSS-61.
122SITC of End Termination of 1.1 kV cable 3.5 C X (95 sq.mm to 150 sq. mm) as perTSS-61.
123SITC of End Termination of 1.1 kV cable 3.5 C X (300 sq.mm to 400 sq. mm) as perTSS-61.
124SITC of Straight Through Jointing of LT cable1.1 kV 4C/3.5 C x185Sqmm as perTSS-62.
125SITC of Straight Through Jointing of LT cable1.1 kV 240 sq mm to 300 sqmm as perTSS-62.
126SITC of LCD VAF Meter, 3Ø, 96X96m as per TSS-63
127Multifunction meter as per TSS-64
128SITC ofEpoxi Floor Painting as per TSS-65
129SITC of MPCB for 3Phase 3HP Inductionmotor as per TSS-66
130SITC ofHigh Voltage Insulation Tester as per TSS-67
131SITC Earth Resistance Tester as per TSS-68
132SITC of Heavy Duty Switch Disconnector Fuse Unit along with HRC Fuse as per TSS-69
133SITC HRC Fuse of rating 20A to 100A as per TSS-70
134SITCof PCB Controller card for BLDC Ceiling Fan as per TSS-71
135SITC of Fly catcher with doube 18W, 2ft tubelight as per -72
136Only installation All type of fans as perTSS-73.
137Only installation of All type of indoor and outdoorlighting fixture as perTSS-73.
138Only installation of 1.5/2.5/4/6 sq mm FRLS/ PVC insulated copper wire as perTSS-73.
139Only installation of 2 pair ATC telephone conductor , Cat 6data cable as perTSS-73.
140Only installation of Cablesize up to OD 16 sq.mm. as perTSS-73.
141Only installation of CableOD from (25 to 80) mm as perTSS-73.
142Only installation of SFU/MCCB/DB etc. as per TSS-73.
143Only installation of Electrical accessories /component viz. Choke/ igniter /capacitor/ starters / holders /lamp /heating coils /lighting tube /rod, lamps etc as perTSS-73.
144Only installation ofPVC casing capping/m.s. conduit /GIFlexible Pipe etc with accessories as per TSS-73.
145Only installation ofCopper Strip/ wire etc. as perTSS-73.
146Excavation of soil as perTSS-74.
147Removal of All type of existing lighting fixtures and fans as perTSS-75
148Removal ofAll type of switch boards as perTSS-75
149Removal ofDistribution boards, SFU, MCCB as perTSS-75
150Removal ofPVC casing capping or MS conduit with PVC wires as perTSS-75
151Removal ofLT power cables, Outer dia up to 25 mm as perTSS-75
152Removal ofLT Power cables, Outer dia above 25 mm and upto 75 mm as per TSS-75
153PCC work with supply of all material as perTSS-76.
Disclaimer :