Military Engineer Services-MES has published Tender For Repair And Replacement Of Unserviceable Insulating Material Of Various Pipe Line, Butterfly Valve, Cable/Cable Tray, Lt Panel Of Chs Plant Installed At Various Unit And Mechanical/ Robotic Cleaning And Repair Of Air Duct Of 153 Gh Chs Sys. Submission Date for this Tender is 09-12-2023. Cable Tray Tenders in Leh Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 27-Nov-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-12-2023 |
2 | 04-Dec-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-12-2023 |
Sl. No. | Item Description |
1 | M&L AHU ducts cleaning using Robot as required on all floors/ducts of 153 GH Leh and submission of Videos recordingbefore-during -after process all as directed by Engr-in Charge. |
2 | Supply and Fix thermal Insulation of AHU ducts using "Closed Cell Polyethylene Foam" of thickness 19-24 mm all as directed by Engr-in-Charge |
3 | M&L for Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying UG cable/MS pipesin trenches on plan and n exc 1.5 m in depth in hard dense soil and getting out all as specified and directed by Engr-in-Charge. |
4 | M&L for Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25m, complete all as specified and directed by Engr-in-Charge. |
5 | M&L for Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the stratingpoint, complete all as specified and directed by Engr-in-Charge. |
6 | Maint. Of Electric Panels M & L for disconnecting the allconnection in existing panel board complete and re-fixing the same after removingthe burnt lugs/thimbles complete including replacing the U/SMCCBS, Contactors, relay,bus barindicator lamps etc., all as specified and as direcrted. Note-MCCBS, Contactors, relay,indicator lamps, S/Switchs are to be measured and paid seperately. |
7 | S&F in replacement of DOL starter MK-1, 1 HP to 3 HP as per existing, complete all as specified and directed. |
8 | S&F inreplacement ofcontactor type 3 TF 33, 415 voltscomplete all as specified and directed. |
9 | S&F inreplacement of contactor type ML 1.5, 220 volts, complete all as speified and directed. |
10 | S&F in replacement of over load relay 8 to 12.5 Amps for contactor series 3 TF 33 complete all as specified and directed. |
11 | S&F inreplacement of over load relay 1.25 to 2Amps for contactor series 3 TF 33, complete all as specified and directed. |
12 | S&F inreplacement of MCCB 63 Amps 10 KA, 3 Pole complete all as specified and directed by Engr-in-Charge. |
13 | S&F inreplacement of MCCB 125 Amps 16 KA, 3 Pole complete all as specified and directed by Engr-in-Charge. |
14 | S&F inreplacementof MCCB 200 Amps, 25 KA, 4 pole 415 Vas per existing complete all as specified and directed. |
15 | S&F inreplacementof MCCB 250 Amps, 25 KA, 3 pole 415 Vas per existing complete all as specified and directed. |
16 | S&F inreplacementof MCB TPN 63 Amps, 10 KA,415 Vas per existing complete all as specified and directed. |
17 | S&F inreplacementof MCB SP 6-32 Amps, 10 KA,415 Vas per existing complete all as specified and directed. |
18 | S&F inreplacementof on load change over switch (side handle) in sheet enclosure, 100 Amp, 415 V, 50 Hz as per existing complete all as specified and directed. |
19 | S&F inreplacementof off load change over switch (side handle) in sheet enclosure, 200 Amp, 415 V, 50 Hz as per existing complete all as specified and directed. |
20 | S&F inreplacement of digital type volt meter0-500 volts,complete all as specified and directed. |
21 | S&F inreplacement of digital type Amp meter complete with suitable CTs 0-300 Amps, complete all as specified and directed. |
22 | S&F inreplacement of rotary type ON/OFF switches, 22mm dia as per existing, complete all as specified and directed. |
23 | S&F inreplacement of push button switch in RED or GREEN colours, 22mm dia as per existing, complete all as specified and directed. |
24 | S&F inreplacement of Selector Type switch as per existing model& type,complete all as specified and directed. |
25 | S&F inreplacement of PVC flexible copper multistrandwire 3 core of 6 sqmm as per existing, complete all as specified and directed. |
26 | S&F inreplacement of PVC flexible copper multistrandwire 3 core of 4 sqmm as per existing, complete all as specified and directed. |
27 | S&F inreplacement of PVC flexible copper multistrandwire 2 core of 4 sqmm as per existing, complete all as specified and directed. |
28 | Maint of Boiler S&F in sequence controller suitable for 3-4 lakh kilo/hr with burner rod assembly, complete all as specified and directed. |
29 | S&F in sequence controller suitable for 1-2 lakh kilo/hr with burner rod assembly, complete all as specified and directed. |
30 | S&F inreplacement ofignition rod suitable for 3-4 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed. |
31 | S&F inreplacement ofignition rod suitable for 1-2 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed. |
32 | S&F in replacement of ignition Transformer electronic type suitable for 3-4 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed. |
33 | S&F in replacement of ignition Transformer electronic type suitable for1-2 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed. |
34 | S&F temp controller digital type DTC 503 with sensor suitable for 3-4 lakh kilo/Cal/hr LAL 2.25 burner rod assembly, complete all as specified and directed. |
35 | S&F temp controller digital type DTC 503 with sensor suitable for 1-2 lakh kilo/Cal/hr LAL 2.25 burner rod assembly, complete all as specified and directed. |
36 | S&F in replacement of pressure guage 0 to 20 Kg/cm sq as per existing, complete all as directed by Engineer-in-Charge. |
37 | S&F in replacement of photo cell as per existing suitable for 3-4 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed. |
38 | S&F in replacement of photo cell as per existing suitable for 1-2 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed. |
39 | S&F in replacement of burner nozzle suitable for 3-4 lakh K/Cal/Hr |
40 | S&F in replacement of burner nozzle suitable for 1-2 lakh K/Cal/Hr |
41 | S&F in replacement of Electrode suitable for burner of capacity 3-4 lakh K/Cal/Hr |
42 | S&F in replacement of Electrode suitable for burner of capacity 1-2 lakh K/Cal/Hr |
43 | S&F for closed cell elastometric insulation 30 to 40 Kg/Cub mtr density 25 mm thick (nitrite insulation) complete all as specified and directed by Engr-in-Charge. |
44 | M&L for repair of exhaust pipe by welding, complete all as specified and directed by Engr-in-Charge. |
45 | Maint of FCU S&F in replacement of fan coil unit parts, duel shaft electric motor of capacity30 watt 930 RPM, 3 speed as per existing, complete all as specified and directed. |
46 | S&F inreplacement of FCU connection of copperpipe 20/16 mm with check nut at both sideas per required length, complete all as specified and directed. |
47 | S&F inreplacement of plug top 15 Amps as per existing, complete all as specified and directed. |
48 | S&F inreplacement of needle valve 3/8" BSP as per existing, complete all as specified and directed. |
49 | S&F in temp controller regulator type , complete all as specified and directed. |
50 | S&F inreplacement of inlet outlet Ball valve 3/4" for FCU as per existing, including supply and fixing MS / GI nipple of size 3/4 inch includig welding work including cutting the existing rusty unserviceable MS/GI nipplecomplete all as specified and directed. |
51 | S&F Inlet/outlet ball copper valves set of 1/4", complete all as specified and directed by Engr-in-Charge. |
52 | S&F Pipe fitting of brass(Nipple outer thread) 1/4"size, completeall as specified and directed by Engr-in-Charge. |
53 | Supply and fixing radiator unit of FCU including connecting with the unit and making it leakproof of copper coils covered with aluminium finsingas per existing size of capacity 4500 K Cal / Hour including dismantling the existing unserviceable. |
54 | Supply and fixing radiator unit of FCU including connecting with the unit and making it leakproof ofcopper coils covered with aluminium finsingas per existing size of capacity 6000 K Cal / Hour including dismantling the existing unserviceable. |
55 | Maint. Of Flow Pipes Supply and replacement of PP-RPipe with fitting of 40 MM size, completeall as specified and directed by Engr-in-Charge. |
56 | Supply and replacement of PP-RPipe with fitting of 32 MM size, completeall as specified and directed by Engr-in-Charge. |
57 | Supply and replacement of PP-RPipe with fitting of 25 MM size, completeall as specified and directed by Engr-in-Charge. |
58 | Supply and replacement of PP-RPipe with fitting of 20 MM size, completeall as specified and directed by Engr-in-Charge. |
59 | S&F inreplacement of gun metal butter fly control valves of 100/125mm bore as per existing, complete all as specified and directed. |
60 | S&F inreplacement of gun metal butter fly control valves of 80mm bore as per existing, complete all as specified and directed. |
61 | S&F inreplacement of gun metal butter fly control valves of 65mm bore as per existing, complete all as specified and directed. |
62 | S&F inreplacement of gun metal butter fly control valves of 40/50mm bore as per existing, complete all as specified and directed. |
63 | Supply and replacement of MS Pipes heavy grade with all fittings of 100 MM size, completeall as specified and directed by Engr-in-Charge. |
64 | Supply and replacement of MS Pipes heavy grade with all fittings of 80 MM size, completeall as specified and directed by Engr-in-Charge. |
65 | Supply and replacement of MS Pipes heavy grade with all fittings of 65 MM size, completeall as specified and directed by Engr-in-Charge. |
66 | Supply and replacement of MS Pipes heavy grade with all fittings of 50 MM size, completeall as specified and directed by Engr-in-Charge. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail