Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORKS(PART-I) Earth work in excavation of foundation in all kinds of soil including dressing and levelling the beds within 50m. initial lead and 1.5m. initial lift with cost, conveyance, taxes as per specification and directionof Engineer in charge |
| 2 | Back filling with available excavated earth in foundation and trenches in layer not exceeding 20 cm in depth watering ramming with a lead upto 50m and lift upto 1.5m etc. incluing cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge |
| 3 | Carriage / disposalof excavated surplusearth from the work side by mechanical means with a lead of 5 km. incluing cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge |
| 4 | Filling foundation and plinth with good quality river sand with watering and ramming incluing cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge |
| 5 | Cement concrete (1:3:6) in foundation and plinth using 4cmsize hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 6 | Cement concrete (1:4:8) in foundation and plinth using 4cmsize hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 7 | Cement concrete (1:2:4) in foundation and plinth using 12mm black hard crusher broken granite stone chips of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 8 | Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Foundation and Plinth for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor |
| 9 | Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Superstructure and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor |
| 10 | 1st floor |
| 11 | Head Room |
| 12 | Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Superstructure and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor |
| 13 | 1st floor |
| 14 | RCC work ofM-25 gradewith 20mm and down graded size crushed stone aggregates mixed by concrete mixer, laying in layers and compacting by vibrator & all leads and lifts including frame works including all cost, conveyance, cost of all labour, T&P etc. complete as per direction and specification of Engineer-in-charge. Base footing |
| 15 | Plinth Beam |
| 16 | Pedestal and Coluumn Superstructure GF |
| 17 | 1st floor |
| 18 | Head Room |
| 19 | LintelGF |
| 20 | 1st floor |
| 21 | Head Room |
| 22 | ChajjaGF |
| 23 | 1st floor |
| 24 | Head Room |
| 25 | Staircase GF |
| 26 | 1st floor |
| 27 | Roof Beam GF |
| 28 | 1st floor |
| 29 | Head Room |
| 30 | Roof slab GF |
| 31 | 1st floor |
| 32 | Head Room |
| 33 | Cutting, straightening coiled or bent up M.S. Rod or tor steel using SAIL/RINL/TATA/JINDAL STEEL/ SHYAM STEEL includingbending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge Ground floor |
| 34 | 1st floor |
| 35 | Head Room |
| 36 | Construction of double under reamed boredpile foundation of 300mm dia with RCC M-25 using crushed broken hard granite chips of 20mm and down graded with required design with cost conveyance taxes cost of all materials but excluding cost of steel and labour etc complete as per specification and direction of Engineer in chargeUpto 6m length |
| 37 | 6-6.5m length |
| 38 | 6-5-7m length |
| 39 | 7-7.5m length |
| 40 | 7-5-8m length |
| 41 | 8-8.5m length |
| 42 | 8-5-9m length |
| 43 | 9-9.5m length |
| 44 | 9-5-10m length |
| 45 | 10-10.5m length |
| 46 | 10-5-11m length |
| 47 | 11-11.5m lengthy |
| 48 | 11-5.-12m length |
| 49 | Supplying, fitting & fixing in all floors of M.S.grillsgate in doors and windows with top rails, steel windows, critical frames for windows balustrades of stair case and parapet railing made out of M.S.square bar/flat as per approved drawing and design including making holes in walls and RCC structure, wood work etc and making good to the damages to walls with cement concrete(1:2:4) with hard crusher broken granite stone chips of 12mm to 20mm size(20mm size not to exceed 25%) of approved quality with cost of all materials with cost of welding all T&P, sundreis etc complete in all respect as per specification and direction of Engineer in charge(screws and other hardward required materials to be used in the work shall be of approved quality and specification and shall have to be supplied by the contractor at his own cost In all floors |
| 50 | Providing and fixing of factory made single extruded WPC door frame with Rebate cuts with finished cross section size 75x45mm or 90x50mm of approved quality including cost, conveyance etc complete as per specification and direction of Engineer in charge |
| 51 | Providing and fixing of 35mm thick WPC door shutter with hinges, tower bolt, handle, stainless steel screw etc. of approved quality including cost, conveyance etc complete as per specification and direction of Engineer in charge |
| 52 | Providing 16mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to inside RCC surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor) |
| 53 | 1st floor |
| 54 | Head Room |
| 55 | Providing 6mm thick cement plaster in cement mortar (1:4) in all floors finished smooth to inside RCCsurface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor) |
| 56 | 1st floor |
| 57 | Head Room |
| 58 | Providing12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to inside ceiling surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor) |
| 59 | 1st floor |
| 60 | Head Room |
| 61 | Providingfitting and fixing of Vitrified tilesColour/printed in floors of size (600mm x600mm ) over 20mm thick bed of cement mortar(1:4)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGF |
| 62 | 1st floor |
| 63 | Providingfitting and fixing of Vitrifiedtiles Colour/printed in dadoesover 12mm thick bed of cement mortar(1:3)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGround floor |
| 64 | 1st floor |
| 65 | Providingfitting and fixing of Granite stone tiles 20mm thick in floors of sizeover 20mm thick bed of cement mortar(1:4)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGF |
| 66 | 1st floor |
| 67 | Providingfitting and fixing of Granite stone tiles10mm thick in dadoesover 12mm thick bed of cement mortar(1:3)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGround floor |
| 68 | 1st floor |
| 69 | Providingfitting and fixing of Kotatiles in floor ofover 20mm thick bed of cement mortar(1:4)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGF |
| 70 | Providingfitting and fixing of Kotatiles in dadoes ofover 12mm thick bed of cement mortar(1:3)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGF |
| 71 | Providing, Fitting & Fixing of Stainless steel of 304 grade in handrailing of 50mm diaof 2mm thick circular pipewith balustrade of size 32mmX32mm X2mm @ 0.90mtr. C/C and stainlesssquare pipes bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost, conveyance ofMaterials, Labour, TandP etc required for the complete in all respect and as per specification & direction of Engineer-in-charge |
| 72 | Finishing wall surface with water based wall putty of approved make and finished smooth and even surface to receive paintingincluding cost of scaffolding staging charges, conveyance, taxes of all materials and cost of all labour with TandP etc complete as per specification and direction of Engineer in charge GF |
| 73 | 1st floor |
| 74 | Head Room |
| 75 | Priming over the plastered surface with one coat of water bound cement primer of approved quality and make including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete as per the direction of Engineer-in-charge GFi(nside wall) |
| 76 | 1st floor |
| 77 | Head Room |
| 78 | Painting with two coats with Plastic emulsion paintof approved quality, make and shade to give an even surface including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete as per the direction of Engineer-in-charge. GF Inside surface |
| 79 | 1st floor |
| 80 | Head Room |
| 81 | Painting two coats with anti-fungal resistance Weather Seal Coatof approved shade upto any height by means of brush to outside surface of walls after cleaning the surface including watering, curring etc. complete in all floors including cost, conveyance, taxes of all materials, labours sundries T&P required for the work as per specification and direction of Engineer in charge Ground floor Outside surface |
| 82 | 1st floor |
| 83 | Head Room |
| 84 | Wall painting with one coat of water bound cement primerto the external wall surface of approved quality and make including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete as per the direction of Engineer-in-charge FFOutside wall |
| 85 | Ground floor |
| 86 | Painting two coats with approved Synthetic enamel paints of approved colour, shade over a coat of primer in Iron work including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour TandP etc complete as per specification and direction of Engineer in charge GF |
| 87 | 1st floor |
| 88 | Head Room |
| 89 | Supplying, Diluting &SpreadingChemical Emulsion like CHLORPYRIPHOSOROther Chemical approved bythe Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer aspreconstructional antitermitetreatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation,top surface ofplinth filling, junction of walls and floorsalong with externalperimeter of thebuilding, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) completeincludingcost, conveyance, loading, unloading and ,es of all materials,cost of all labour, T&P, sundries and scaffoldingwhere required for the work etc.as directed by the Engineer -in -charge.( The payment shall be made on the basis of theactual measurement of the plinth area of the building at Ground Floor and vertical faces will not be measured for payment) |
| 90 | Providing 2.5cm thick grading concrete of prop.(1:2:2) on roof slab using 4.7 mm size H.G. chips of approved quality & from approved quarry including watering, curing withcost, conveyances, taxes of all materials, cost of all labour, T&P required for the work etc. complete as per direction of Engineer-in-chargeGFF |
| 91 | 1st floor |
| 92 | Head Room |
| 93 | Providing and fixing of factory made UPVC 2-track sliding/3 track window complete, comprising UPVC multi-chambered frame of size 67mmx54mm with wall thickness of 2.33mm (+-0.2mm) having inbuilt UPVC roller track on top and UPVC sash of size 64mmx47mm with wall thickness of 2.3mm (+-0.2mm) duly reinforced with G.I section 1.2mm (+/- 0.2mm), whereever required. All corners of frame and sash will be fision welded. After placing 5mm clear Annealed glass in sash,UPVC glazing bead, interlock, EPDM gaskert, brush will be provided including hardware, i.e, touch lock and rollers & proper drainage system shall be provided. Window will be fixed to the wall with 100mm long and 8mm dia |
| 94 | Providing and lying integram cement based water proffing traetment including preparertion of surface as required for treatment of roofs, balconies, terrace etc consisting of following operations: (a) Applying a slurry cot of neaat cement using 2.75kg/sqm of cement aadmixed with water proffingcompound comforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoiningwalls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using briken bricks/brick bats 25 mm to 115 mm sizewith 50% of cement mortr 1:5 (1 cement : 5 coaarse sand) admixed with water proffing ompound conforming to IS : 2645 and approved by Engineer-in-charge over 20mm thick laayer of cement mortr of mix 1:5 (1 cement 5 coarse saand) admixed with water proffing compound conforming to IS : 2645 and approved by Enginer-in-charge to required slope and treating similarly the adjoining wall up to 300 mm height including rounding of junctions of waall and slabs. (c) After two dys of proper curing applying a second coat of cement slurry using 2.75 kg/sqqm of cement admixed with water proffing compound conforming to IS : 2645 and approved by Engneer-in-charge. (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 Coarse cement sand) admixed with water proffing compound conforming to IS : 2645 and approved by Engneer-in-charge |
| 95 | Providing and fixing of GFRC screens including CNC cuttingin approved design, size & thickness is 25mm +/- 5% as per drawing or giver pattern manufactured containg alkaline resistant glass fiber of make NES, Japan or CEMFIL, Spain etc. including cost of all material as per the requirementto be fixed for direct application on the wall ,there will not be a over lappingmake in position with necessary accessories withscafolding complete in all respect excluding GSTas directed by the Engineer-in-charge. |
| 96 | Supplying, fitting and fixing in position chequredtile of approved make andquality, colour and size in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and with Portland Slag Cement (PSC) grouted with neat white cement slurry with required quantities of pigments of approved marks watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work complete in all respect as directed by the Engineer-in-charge GF |
| 97 | EI work- GROUP A :Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit(Norpack/Eq make), with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Make :Legrand(Myrius)/schneider(Zencelo)/Panasonic(Vision)/Eq make |
| 98 | GROUP B:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit(Norpack/Eq make), with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Make :Legrand(Myrius)/schneider(Zencelo)/Panasonic(Vision)/Eq |
| 99 | GROUP C:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit(Norpack/Eq make), with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Make :Legrand(Myrius)/schneider(Zencelo)/Panasonic(Vision)/Eq |
| 100 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit(Norpack/Eq make), and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (Make :Legrand(Myrius)/schneider(Zencelo)/Panasonic(Vision)/Eq |
| 101 | Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLS PVC insulated single core multistrand copper conductor of ISI marked in recess 20 mm dia non-metalic PVC flexible conduit(Norpack/Eq make) with modular type switch ,4 module 18SWG modular GI box and earthing point with 1 x 1.5 sq.mm FRLS PVC insulated single core multistrand copper conductor for loop earthing etc. as required. ( Make of wire Finolex/ Anchor / Havels / V Guard/KEl )/RR cable/Eq make |
| 102 | Supplying and fixing of 4module GI box with cover on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 5 pin 15 / 16 amps socket outlet and 15 / 16 amps modular type switch, connection, painting etc as required.(Make-Anchor/crabtree/Legrand/Hager) /Eq make |
| 103 | Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLS PVC insulated single core multistrand copper conductor of ISI marked in recess 20 mm dia non-metalic PVC flexible conduit(Norpck/Eq make) with modular type switch ,6 module 18SWG modular GI box and earthing point with 1 x 1.5 sq.mm FRLS PVC insulated single core multistrand copper conductor for loop earthing etc. as required. ( Make of wire Finolex / Anchor / Havels /KEI/ RR cable/ )/Eq make |
| 104 | Supply and fixing of 20 amp 240 V SPN industrial type socket outlet with 2 pole and earth metal encloser plug top along with 20 amp \"C\" series SP MCB in sheet steel enclosure on surface or in recess with chained metal cover for the socket outlet and complete connections, testing and commissionig etc. as required.(Make-Legrand (Mylink)/Siemens/Hager/Eq make) |
| 105 | Supplying and fixing of 100W,step typeregulator, 2 Modulewithout base and cover including connection etc as required.(Make :Legrand(Myrius)/schneider(Zencelo)/Panasonic(Vision)/Eq |
| 106 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 107 | Wiring to Telephone Socket Outlet from Junction Box with 0.5 mm2 Twin Pair Copper Conductor Telephone Wire run inside prelaid PVC Conduit(Norpack/Eq make) complete including termination, testing etc complete as required and as perDirection of Engineer-In-Charge. (Make :Legrand(Myrius)/schneider(Zencelo)/Panasonic(Vision)/Eq |
| 108 | Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe and making good the damages caused complete as required and as perDirection of Engineer-In-Charge. (Make :Legrand(Myrius)/schneider(Zencelo)/Panasonic(Vision)/Eq |
| 109 | Supplying and fixing of RJ11 telephone jack single with shutter & RJ 45 computer jack with shutter, 2modulemodularbase and cover including connectionfor telephone and LAN . (Make :Legrand(Myrius)/schneider(Zencelo)/Panasonic(Vision)/Eq |
| 110 | Supplying and fixing T.V. antenna socket outlet piano type ISI marked on the existing switchboard / cover including connections etc as requird. |
| 111 | Supply, delivery and laying of following sizes of 2 mm Wall thickness rigid20MM PVC Conduit Concealed in Wall/ Column/ Roof Slab of the Building or mounted on surface along with other accessories and 18 SWG GI Fish Wire complete for Telephone / TV / Computer / Circuit or Sub main wiring as required & as perDirection of Engineer-In-Charge. |
| 112 | Supply, delivery and laying of following sizes of 2 mm Wall thickness rigid 25MMPVC Conduit Concealed in Wall/ Column/ Roof Slab of the Building or mounted on surface along with other accessories and 18 SWG GI Fish Wire complete for Telephone / TV / Computer / Circuit or Sub main wiring as required & as perDirection of Engineer-In-Charge. |
| 113 | Wiring for Circuits and Submain with following number & sizes of PVC insulated 1100 Volt Grade Multistranded Copper Conductor FRLSWire run inside 2 mm thick PVC Conduit Pipe Recessed in Ceiling / Column / Walls of Building including supply of all materials such as wires, PVC Conduit, Junction Box & Pull Box etc. complete with making good the damages caused as required and as perDirection of Engineer-In-Charge. (Make of wire Finolex/Anchor/Havels/KEI)2 Nos. Single Core 1.5 mm2 FRLSCopper Wire for Phase and Neutral and 1 No. Single Core 1.5 mm2 FRLS Copper Wire for Earth Continuity Conductor as per SLD (Make of wire Anchor/Havels/KEI) |
| 114 | 2 Nos. Single Core 2.5 mm2 FRLSCopper Wire for Phase and Neutral and 1 No. Single Core 1.5 mm2 FRLS Copper Wire for Earth Continuity Conductor as per SLD (from LDB to Room & Power Point and Common Light Point looped).(Make of wire Anchor/Havels/KEI) |
| 115 | 2 Nos. Single Core 4.0 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 2.5 mm2 FRLS Copper Wire for Earth Continuity Conductor as per SLD.(Make of wire Anchor/Havels/KEI) |
| 116 | 2 Nos. Single Core 10 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 4 mm2 FRLS Copper Wire for Earth Continuity Conductor as per SLD.(Make of wire Anchor/Havels/KEI) |
| 117 | 4 Nos. Single Core 16.0 mm2 FRLS Copper Wire for Phase and Neutral and 2 No. Single Core10 mm2 FRLS Copper Wire for Earth Continuity Conductor as per SLD.(Make of wire Anchor/Havels/KEI) |
| 118 | BRANCH DISTRIBUTION Supplying and fixing following way, Three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way, TPN DB Double door |
| 119 | Supplying and fixing following rating, 63 amp 4pole RCBO, (Three phase and neutral), 415 Vhaving a sensitivity current 10 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 120 | Supplying and fixing Single pole 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 121 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 122 | Main Panel Board:Incoming: 100 Amp. 4P MCCB 25 KA(Thermal Magnetic Release)- 1No,125 AMP 4WAYMANUAL CHANGOVER SWITCH 1 NO Equiments: 4 Nos. 100 Amp. Copper Bus Bar coated with PVC Heat Shrunk Sleeve (Colour Code). 1 No. VAF Digital Meter.3 Nos. RYB LED Indicator. 3 Nos.100 / 5 Amp. C.T. Operated. Outgoing:1 Nos of sub Meter connection ,4 Nos 63 AMP 4P MCB 10 KA 3 Nos 40 AMP 2P MCB 10 KAWith spreadentinle & cable alloy |
| 123 | FITTINGS & FIXTURES: Supply,Installation and testing of following types of LED Tube Fixtures Directly on Wall / Ceiling/ Structure of Building with all accessories such as Electronics Ballast, Lamps, Stove Enameled Box, Perplex Sheet Cover etc. complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge. Make-WIPRO ,LT,PHILIPS,PANASONIC/Eq make Supplyof Surfacemounted indoortype 20 WATT LED(110lumen/watt)Inverter LED Batten with Opal Diffuser, IP20, Battery back-up & Functioning as per Product TDScomplete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge |
| 124 | Supplyof18 watt (110lumens/watt)Surfacemounted indoortype Round LEDLuminaire withLED GLARE FREE opal diffuser ,IP20 Lamp complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge |
| 125 | Supplyof 10 WATT LED BOLLARD LIGHT complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge |
| 126 | Supply 36 W LED premises LIGHT6500 CCT fixtures ,complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge. |
| 127 | Supply of 10 WInverter LED Bulb in B-22 cap and with Opal Diffuser, IP20, Battery back-up & Functioning as per Product TDSLuminaire withLEDcomplete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge |
| 128 | Supply of3 WATT LED BED BULB type Luminaire withLEDcomplete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge |
| 129 | Installation, testing and commissioning of pre-wired, LED fitting / compact LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 130 | Numbering of ceiling fan/ exhaust fan/ light fittings as required. |
| 131 | Supply, delivery, installation and testing of following Sweeps of High Speed Energy1200 mm 48 \"\"Sweep Ceiling Fan 225 CMM Air Delivery. Efficient A.C. Ceiling Fan complete with Fan Blades, Down Rod, Canopies & Capacitor etc.including supply of Sundry Materials, making connection from the suitable point outlet but excluding cost of Fan Regulator complete as required and as per theDirection of Engineer-In-Charge.(Make-Usha(Striker Neo)/Crompton (HS)/ Havells(SMRAT)/Eq) |
| 132 | Supply, delivery, installation & testing of following Sweep & Speed 230 mm EXHAUST FAN 1400 RPM.on Existing Sheet Metal Switch Board including loop connections and making good the damages caused complete as required and as per direction of Engineer-in-charge(Make-USHA , Halonix, Pansonic,Bajaj) |
| 133 | EARTHING: Providing and fixing 25 mm x 5 mm Copper earth strip in 40 mm dia G.I. pipesurface or in recess as strip electrodefor connections etc. as required.and making good the damages caused complete as required and as per direction of Engineer-in-charge |
| 134 | Extra for using salt and charcoal for G.I or copper plate earth as required and making good the damages caused complete as required and as per direction of Engineer-in-charge |
| 135 | Providing and fixing 8 SWG COPPER wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required and making good the damages caused complete as required and as per direction of Engineer-in-charge |
| 136 | Earthing with COPPERplate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required.and making good the damages caused complete as required and as per direction of Engineer-in-charge |
| 137 | CABLE Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 120 sq.mm but not exceeding 400 sq.mm direct in ground in the same trench in one , sand cushioning, protective covering and refilling the trench etc. as required. |
| 138 | Supply, Laying and Testingof following Size XLPE insulated 1.1 Kv alluminium armoued cable making good the damages caused as required complete as perDirection of Engineer-In-Charge. (Make: polycab,KEI) 50 mm2 3 1/2 Core , Al Armoured , XLPE Cable |
| 139 | Supply of all materials like cable lugs, gland etc as required & terminal of below mentioned cable complete as per required technical specifications & direction of EIC 50 mm2 3 1/2 Core , Al Armoured , XLPE Cable |
| 140 | Supplying of following Materials First Aid Box. |
| 141 | Shock Treatment Chart (Odia / Hindi & English). |
| 142 | 8 mm thick Rubber Mat. |
| 143 | ABS type Fire Extinguisher of 4.5 Kg. |
| 144 | Danger Board. |
| 145 | AC EQUIPMENT Nominal Capacity - 2.00 TR single phase |
| 146 | Supply,installation, testing and commissioning of Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all piping.Make of pipe-Rajco/Mandev/Maxflo/Eq.Make of insulation-Aeroflex/K-flex/Supreme/Eq. Suction Linepipe with 19mm thick insulation 15.9 mm |
| 147 | 9.5 mm |
| 148 | Supply, installation, testing & Commissioning of following sizes insulated PVC drain pipes insulated with 9mm thick nitrile rubber insulation of following size32/40 mm Dia with 9mm Nitrile Rubber Insulation |
| 149 | Supply, installation, testing & Commissioning of following sizes stand for outdoor machine support complete with making good the damages caused as required and as perDirection of Engineer-In-Charge. |
| 150 | Control & Transmission Wiring : Supply Installation Testing and Commission of 4 C x 1.5 sq.mm Cu communication cable Control wiring of copper in suitable conduits between indoor and outdoor units complete with making good the damages caused as required and as perDirection of Engineer-In-Charge. Make: Polycab/ Havells/ Anchor/ RR Cabel/ Finolex/Eq. |
| 151 | Supply & Comissioning of Refrigerant R-32 gas |
| 152 | PH work- Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipesconforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge.Ground Floor 25mm dia PVC ASTM pipe (sch-80) |
| 153 | 32mm dia PVC ASTM pipe (sch-80) |
| 154 | 40mm dia PVC ASTM pipe (sch-80) |
| 155 | First Floor25mm dia PVC ASTM pipe (sch-80) |
| 156 | 32mm dia PVC ASTM pipe (sch-80) |
| 157 | 40 mm dia PVC ASTM pipe (sch-80) |
| 158 | 50 mm dia PVC ASTM pipe (sch-80) |
| 159 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipesconforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brassthreaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Jointsall complete as per specification and direction of the Engineer in charge.Ground Floor 20mm dia CPVC pipe |
| 160 | 25mm dia CPVC pipe |
| 161 | First Floor 20mm dia CPVC pipe |
| 162 | 25mm dia CPVC pipe |
| 163 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mmthick wallGround Floor |
| 164 | First Floor |
| 165 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of theEngineer in charge. Ground Floor |
| 166 | First Floor |
| 167 | Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. Ground Floor |
| 168 | First Floor |
| 169 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. 15 mm dia 2 WAY BIB COCK WITH WALL FLANGE (FLR-CHR-5041NJaquar Make) |
| 170 | 15mm dia CP Health Faucet(ALD-CHR- 577) |
| 171 | 15 mm dia CP Long bodyBib cock( FLR-CHR-5043N Jaquar make ) |
| 172 | 15mm dia CP ANGULAR STOP COCK WITH WALL FLANGE (FLR-MCH-5053N Jaquar Make ) |
| 173 | 20mm dia CP CONCEALED STOP COCK WITH WALL FLANGE (FLR -MCH -5083N Jaquar)make |
| 174 | 15mm dia C.P. Pillar cock (FLR-MCH-5011N Jaquar make) |
| 175 | Pillarcock with extension body FLR-MCH- 5021 N |
| 176 | Sink Cock - Jaquar Make - FLR-CHR-5357N |
| 177 | WALL MIXER NON TELEPHONIC Jaqur make - FLR-MCH-5219N |
| 178 | 32mm dia CP Bottle trap (jaquar make )-ALD -CHR -769L-300X190cm |
| 179 | Supplying all materials, labour, T&P and fitting and fixing CP shower with 15mm or 20mm inlet with CP shower arm including polishing all complete as per specification and direction of the Engineer in charge.15mm dia CP revolving shower With shower arm(Jaquar)OHS-CHR-1985+SHA-CHR-477 |
| 180 | Glass shelf 600mm long(ACN-CHR-1171N) |
| 181 | Towel Ring Round - (As Per Jaquar,Cat no.:ACN-CHR-1121BN) |
| 182 | 600mm long CP towel rail(Jaquar)-ACN-IVY-1111NM |
| 183 | Soap Holder AKP-ABR-35731P(Jaquar make) |
| 184 | Corner shelf ACN-CHR-1173(Jaquar make) |
| 185 | 25mm dia brass or gun metal fullway valve (Shakti Make) |
| 186 | 32mm dia brass or gun metal fullway valve (Shakti Make) |
| 187 | 50mm dia brass or gun metal fullway valve (Shakti Make) |
| 188 | 15mm dia CP flange |
| 189 | 15mm dia CP extension piece |
| 190 | C.P. Waste 11/4\" |
| 191 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering,watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 1000Ltr Roto-moulded water storage tank (Syntax Make) In FIRST FLOOR |
| 192 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering,watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000Ltr Roto-moulded water storage tank (Syntax Make) In SECOND FLOOR |
| 193 | Supplying all materials, labour, T&P and fitting and fixing10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge10 litres capacity pvc low level cistern with 32mm dia CP long flush bendSlimline white(Hindware / Parryware Make) |
| 194 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor110mm dia U-PVC SWR pipe (Ashirbad /Sentinity/Supreeme) |
| 195 | 110mm U-PVC door tee |
| 196 | 110mm U-PVC Plain tee |
| 197 | 110mm U-PVC door bend |
| 198 | 110mm U-PVC plain bend |
| 199 | 110mm dia U-PVC \"P\" trap |
| 200 | 110mm dia U-PVC Plain Shoe Bend |
| 201 | 110mm dia U-PVC offset with out ear |
| 202 | 110mm dia U-PVC cowl |
| 203 | 125mm dia CP grating |
| 204 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge.250mm to 375mmthick wall |
| 205 | Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge. |
| 206 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge580mm size Orissa pan (Parryware / Nycer make) |
| 207 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. EWC SINGLE PIECE-WC WITH PP SOFT CLOSE SEATSLS-SLS-WHT-6851P |
| 208 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste,etc all complete as per specification and direction of the Engineer in charge. 550mmx440 mm size wash hand basin With porcelain pedestal(Parrywaremake) |
| 209 | Table top basin JDS-WHT-25935 (Jaquar make) |
| 210 | Supplying all materials, labour, T&P and fixing wash kitchen sink with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge. 600x450x250 mm stainless steel kitchen sink-glossy-IS:13983 - 1994 (Jayna make) |
| 211 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge. Design mirror |
| 212 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder |
| 213 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. Groundfloor. |
| 214 | Firstfloor . |
| 215 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge -Groundfloor . |
| 216 | Firstfloor . |
| 217 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany / Johnson to be pre-approved 600 x 600mm of size Groundfloor |
| 218 | first floor |
| 219 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany 600 x 300 cm size ofGround floor |
| 220 | First floor |
| 221 | Supplying all materials, labour, T&P and fixing granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. In Groundfloor |
| 222 | first floor |
| 223 | Supplying all materials, labour, T&P and providing distempering 2 coats to walls with distemperof approved shade on new work to give an even shadeetc all complete as per specification and direction of the Engineer in charge. In ground floor |
| 224 | First floor |
| 225 | Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete.In Ground floor |
| 226 | In first floor |
| 227 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finishstructural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material,The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre\"s standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I (ISI marked) size 100mm are to be fitted on one side of shutter. |
| 228 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigmentscomplete in all respect as per specification and direction of the Engineer in charge |
| 229 | Supply of all materials & laying the waterproofing material Pidifin 2K of Dr.Fixit on equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1\"6\" in wall including cleaning,applying and mending as per specification including cost,conveyance,taxes,royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge.First floor |
| 230 | 12 mm thick cement plaster (1:4) over brick work with cement punning for skirting.First floor |
| 231 | Supplying all materials, labour, T&P and filling in sunken floor in toilets with cinter (light weight slag) well watered and rammed include conveyance of all materials to worksite payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge First floor |
| 232 | Sinking of 150mmdia tubewell through hand boring (water jet ) method (1 nos) .Supplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge |
| 233 | Supplying alllabour, T&P and transporting the boring pipes, top casing , grouting pipes, P.V.C pipes and fittings, P.V.C well screens, cement, bentonite and gravels etc to the worksite including loading and unloading etc all complete as per direction of Engineer in charge |
| 234 | Supplying alllabour, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kinds of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per direction of Engineer in charge. Drilling pilot bore from 0 to 360 metres2 x 100 |
| 235 | Supplying alllabour, T&P and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer in charge Reaming 100mm to 150mm diafrom 0 to 360 metres |
| 236 | Reaming 150mm to 200mm dia from 0 to 360 metres |
| 237 | Supplying alllabour, T&P and jointing materials and lowering the 300mm dia top casing pipes into the position and removing the same after use all complete as per direction of Engineer in charge from 0 to 360 metres |
| 238 | Supplying all labour T&P and grouting with cementslurry for salinesealing intheborearoundthe 150 mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. |
| 239 | Supplying alllabour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge 150mm dia PVC casing pipefrom 0 to 360 metres |
| 240 | Cost of 150mm dia PVC ASTM pipe (sch-80) |
| 241 | Cost of 150mm dia PVC pipe Cutting slot |
| 242 | Cost of150 mm dia C.I. staoner cutting. |
| 243 | Cost of bentonite powder |
| 244 | Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction of the Engineer in charge |
| 245 | Cost and Conveyance of Gravel |
| 246 | Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack etc all complete as per the direction of the Engineer in charge |
| 247 | Cost and Conveyance of sand |
| 248 | Supplying all labour T&P and grouting with cementslurry for sanitary sealingintheborearoundthe uppermost 3 metres of125/100mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. |
| 249 | Cost of Cement |
| 250 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By Compressor |
| 251 | Supplying all materials, labour, T&P and constructingBore well protectionchamber of the inside size 650x650x1000hightwith cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ashbrickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4)inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. |
| 252 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge1 .00 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm |
| 253 | 2.0 HP Horizontal submerssible pump motor |
| 254 | DOL Control panel |
| 255 | 40mm dia steel short piece |
| 256 | Well cap |
| 257 | 50mm size CI bracket |
| 258 | 2.50sqmm flat cable |
| 259 | 20mm dia rigid UPVC pipes |
| 260 | Steel rope with cover |
| 261 | 40mm dia HDPE pipe |
| 262 | Labour charges for lowering including transportation |
| 263 | EXTERNAL P.H. WORK Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 110mm dia U-PVC Alround Concrete |
| 264 | 160mm dia U-PVC Alround Concrete |
| 265 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm |
| 266 | Supplying all materials, labour, T&P and constructing inspection chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ashbrickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm |
| 267 | ---- do --- addl depth of 0.15m upto 0.90m |
| 268 | R.C.P.C.Manhole Cover |
| 269 | Supplying all materials, labour, T&P and constructing man hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm |
| 270 | R.C.P.C.Manhole Cover |
| 271 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy