Border Security Force-BSF has published Tender For Renovation Upgradation Of Existing Toilet Blocks 06 Nos Wc And 08 Nos Bathroom For Trainees Near Gym Hall And Barracks At Cedco Bsf Banglore Sh Ei Service Connection And Fans. Submission Date for this Tender is 13-11-2023. Barrack Tenders in Bengaluru Urban Karnataka. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. |
3 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
4 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator 12 way , Double door |
5 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 Amp |
6 | Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
8 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
9 | Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc.as required.6 Module (200mmX75mm) |
10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
11 | 15/16 A switch |
12 | 6 pin 15/16 A socket outlet |
13 | Supplying ,Installation ,Testing and commissioning of1200 mm ceiling fanincluding wiring the down rod of standard length (Upto 30 cm ) with 1.5 sq mm FRLS PVC Insulated copper conductor ,single core cableetc as required of Bajaj/ Usha/ Crompton/Havells or its eqt make. |
14 | Supplying and Installationof LEDluminarie suitable for18 watt surfaceround LEDlight ,230 volt ,50Hz ,AC supply with high power LED lamp ,electronic driver ,diffuser including connection as required of Havells/Crompton/Bajaj/Phillips make. |
15 | Supply ,Installation of 300 mm sweep metalic exhaust fan including louver /shutter in existing opening ,including making good the damage ,connection ,testing commissioning etc as required (Havells / Bajaj/Crompton make). |
16 | Supplying and fixing of aluminium housing 20 watt surface/wall mounted LED batten and integrated driver including connection as required of Havells/Crompton/Bajaj/Phillips make. |