Military Engineer Services-MES has published Tender For Repair And Maintenance Of Fire Alarm System At Site A Under Ge Sb Karwar. Submission Date for this Tender is 29-11-2023. Alarm Systems Tenders in Karwar Karnataka. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 09-Nov-2023 | CORRIGENDUM NO 1 | Other | 22-11-2023 |
2 | 22-Nov-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-11-2023 |
Sl. No. | Item Description |
1 | Labour only for Non Comprehensive Routine maintenance checkup of Fire alarm system"s error and alarms, necessary inspection of the Fire alarm system and take necessary corrected actions,resolve any issues regarding the system and take corrective actions for the problems , check connectivity and communication at all terminations,check all power sources and outlets used in the system complete for all panels all Fire alarm system at site "A" by authorised service engineer of OEM and furnish the report to Engineer-in-charge. |
2 | (a) All as per above item No 1 but for ABBAKKABuilding at Little Binaga. |
3 | (b) All as per above item No 1 but for CHINNAMMABuilding at Little Binaga. |
4 | (c) All as per above item No 1 but for M .C.P.OBuilding at Kadmba Vanam. |
5 | (d) All as per above item No 1 but for MAIN M.O BUILDING & M.O WAREHOUSE & M.O STORE & M.OCENTEENBuilding at Core Area. |
6 | (e) All as per above item No 1 but for VB YardBuilding at Core Area |
7 | (f) All as per above item No 1 but for CT Pool at Core Area |
8 | (g) All as per above item No 1 but for HQ Kadamba Building at Core Area |
9 | (h) All as per above item No 1 but for HangarBuilding at Core Area |
10 | (j) All as per above item No 1 but for Patanjali HospitalBuilding at Core Area |
11 | (k) All as per above item No 1 but for HQ Main Building at Core Area |
12 | (l) All as per above item No 1 but for NSRY Fire stationBuilding at NSRY. |
13 | Supply , installation , testing & commissioning in repairsAddressable fire alarm control panelsingle Loop complete all as specified and directed by Engineer-in-charge. |
14 | Supply , installation , testing & commissioning in repairsAddressable fire alarm control paneldouble Loop complete all as specified and directed by Engineer-in-charge. |
15 | M&L in repair converntional type 16 zone fire alarm panel upto 20 detectors per zone with 6 hours battery back up, detector circuit monitored for open circuit, short circuit and 16 zone panel.including 2 No 12V,7 AH dry rechargeble batteryetccomplete all as specified and directed by Engineer-in-Charge. |
16 | M&L in repair converntional type 10 zone fire alarm panel upto 20 detectors per zone with 6 hours battery back up, detector circuit monitored for open circuit, short circuit and 10 zone panelincluding 2 No 12V,7 AH dry rechargeble batteryetccomplete all as specified and directed by Engineer-in-Charge. :- |
17 | Supply and fix inreplacement Addressabledual loopcard complete all as specified and directed by Engineer-in-Charge. |
18 | Supply and fix in replacement Zone cards10 zone card &16zone card & 8 zone &4 zoneetccomplete all as specified and directed by Engineer-in-Charge. |
19 | Supply & installation in repairs of Addressable Smoke detector along with required accessories complete all as specified and directed by Engineer-in-charge. |
20 | Supply & installationin repairs of Addressable Heat detector along with required accessories complete all as specified and directed by Engineer-in-charge. |
21 | Supply & installation in repiars of Addressable Multi Sensor detector along with required accessories complete all as specified and directed by Engineer-in-charge. |
22 | Supply & installation in repairs of Addressable Isolator Module along with required accessories complete all as specified and directed by Engineer-in-charge. |
23 | Supply & installationin repairs of Addressable Control Module along with required accessories complete all as specified and directed by Engineer-in-charge. |
24 | Supply & installation in repairs of Addressable Sounder cum strobe along with required accessories complete all as specified and directed by Engineer-in-charge. |
25 | Supply & installationin repairs of Addressable Manual Call Point along with required accessories complete all as specified and directed by Engineer-in-charge. |
26 | Supply & Laying in repairs of 2 Core 1.5 Sq mm Copper Flexible Cable for control wiring with & including copper lugs, connectors etc complete all as specified and directed by Engineer-in-charge. |
27 | Supply & Fix in repairs lead acid typebattery of 12 Volts 7 AH capacity complete all as specified and directed .Make exide or Equivalent. |
28 | Supply and installation in repair of network card of Fire Alarm control panel complete all as specified and directed |
29 | Supply and installation in repair of Power supply of Fire Alarm control panel complete all as specified and directed |
30 | Supply and installation inrepair of Display of Fire Alarm control panel complete all as specified and directed |
31 | Supply and installation in repair of loop card of Fire Alarm control panel complete all as specified and directed |
32 | Supply and installation inrepair of mother board of Fire Alarm control panel complete all as specified and directed |