Tender For Additional /Alternator To Building No P-59 And Upgradation Of Em Equipments Under Ge ( I ) Gos., gopalpur-Odisha

Military Engineer Services-MES has published Tender For Additional /Alternator To Building No P-59 And Upgradation Of Em Equipments Under Ge ( I ) Gos.. Submission Date for this Tender is 13-11-2023. Building Work Tenders in gopalpur Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

40426686
Tender For Additional /Alternator To Building No P-59 And Upgradation Of Em Equipments Under Ge ( I ) Gos.
Open Tender
Indian
Odisha
gopalpur
13-11-2023

Tender Details

Tender For Additional / Alternator To Building No P-59 And Upgradation Of Em Equipments Under Ge ( I ) Gos. ; 1 Taking Down The Chowkhats Or Frames Exc 1.5 Sqm But N Exc 4 Sqm Each ( Without Taking Off Shutters From The Frames ) Complete All As Specified And As Directed 2 Taking Down The Shutters Of Any Description N Exc 1 Sqm Each Complete All As Specified And As Directed 3 Demolition Of Brickwork Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, But Excluding Ashlar Facings, Dressed Stonework And Precast Concrete Articles Complete All As Specified And As Directed 4 M&L Brick Work With Modular Fly Ash Bricks Straight Or Curved On Plan Exc 6M Mean Radius Built In Cm 1:6 Complete All As Specified And As Directed 5 M&L For Taking Down Cement Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc Complete All As Specified And Directed. 6 M&L For Rendering 15 Mm Thick On Fair Faces Of External Wall Of Brick Work Or Stone Surfaces In Two Layers ( 10 Mm And 5 Mm Thick ) In Cement Mortar In 1:4 Using Water Proofing Compound In Top Layer ( Water Proofing Compound Measured Separately ) Andfinished Even And Smooth ( Without Using Extra Lime Or Cement ) Complete All As Specified And Directed. 7 M&L For Rendering 10 Mm Thick Internal Wall On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar In 1:6 Andfinished Even And Smooth ( Without Using Extra Lime Or Cement ) Complete All As Specified And Directed. 8 M&L For Rendering 5 Mm Thick On Ceiling In Cement Mortar 1:3 Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed 9 Supply Only Liquid Water Proofing Compound For External Wall Plastering ( For 5 Mm Thick Plastering ) Complete All As Specified And Directed 10 M&L For Preparaion Of Newly Plasteredsurfaces Of Walls Andfinishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade: New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) Complete All As Specified And As Directed. 11 M&L For Preparing Newly Plastered Surfaces Of Walls, Etc And Applying Three Coats Of White Wash Complete All As Specified And As Directed. 12 M&L For Preparation Of New Plastered Surfaces Of Ceiling And Applying Three Coats Of White Wash Complete All As Specified And As Directed. 13 M&L For Hardcore Of Broken Stone Or Boulders Guage N Exc. 63 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed. 14 M&L For 100 Mm Thick Cement Concrete Type D-2, 1:4:8 ( 40Mm Graded Aggregate ) In Subbase Of Floor Etc Complete All As Specified And As Directed. 15 M&L For Chequered Cement Concrete Tiles 20Cmx20cmx25mm Thick, Set, Joined And Pointed In Neat Cement Slurry In Floors With Grey Cement And Pigment Complete All As Specified And Directed. 16 M&L For 40 Mm Thick Cement Concrete Type B-0, 1:2:4 ( 12.5Mm Graded Aggregate ) In Sub Base Finishing Cement Concrete Surface Even And Smoothwithout Using Extra Cement Complete All As Specified And As Directed 17 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) , Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And As Directed 18 M&L For Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over 15 Mm Thick Screed Bed Or Bedding Layer Of Cement Mortar In 1:6 For Laying Floor Finishes Complete All As Specified And As Directed 19 M&L For Coloured Glazed Ceramic Tiles In Vertical Surface Of Size 450X 350X 7 Mm Thick Over 10 Mm Thick Back Coat Of Cement Mortar In 1:4Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match Over Complete All As Specified And As Directed. 20 Demolition Of Unreinforced Cement Concrete In Ground Floors And Pavings N Exc 15 Cm Thickness ( Below Or Above Ground Level ) Complete All As Specified And Directed 21 M&L For 75 Mm Thick Cement Concrete Type C-2, 1:3:6 ( 40Mm Graded Aggregate ) In Plinth Protection, Finishing Cement Concrete Surface Even And Smoothwithout Using Extra Cement Complete All As Specified And As Directed 22 M&L For Forming Contraction ( Dummy ) Joints 65Mm Deep X 10Mm Wide, Filled With Sealing Compound Grade A Complete All As Specified And As Directed 23 M&L For 25 Mm Thick Cement Concrete Type B-0 1:2:4 ( 12.5 Mm Graded Aggregate ) Complete All As Specified And As Directed 24 Dismantling Of Water Tank Capacity Exc 500 Not Exc 1000 Ltrs And Removing To Store Complete All As Specified And As Directed 25 Hoisting And Fixing Of Rotational Moulded Polyethylene Water Storage Tanks ( Cylindrical Vertical With Closed Top ) Of Capacity 1000 Ltrs Hoisted And Fixed In Position Specified In Ssr Part I Complete All As Specified And As Directed. 26 S&F For 20 Mm Bore, Ball Brass Valves, High Pressure, With Polythene Float And Flynut Complete, Screwed For Iron Pipe Or Brass Ferrule And Fixed Complete All As Specified And As Directed. 27 S&F For Factory Made Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S. Square Tube, Suppling & Fixing In Opening As Per Specification & Drawing In Ssr Part Ii 2010 Complete All As Specified And As Directed 28 S&F For Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick ( Style ) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails. M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc ‘C’ Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing In Ssr Part Ii 2010 Complete All As Specified And As Directed 29 S&F100 Mm Long Butt Hinges, Medium Weight, Cold Rolled Mild Steel Fixed To Chowkats Complete All As Specified And Directed 30 S&F Aluminium Handle 100 Mm Long Cast Type, Anodised Extruded Fabricated Type Complete All As Specified And As Directed. 31 S&F Aluminium Anodised Barrel Tower Bolts Of Extruded Section 100 Mm Long Complete All As Specified And Directed. 32 S&F 300 Mm Long Aluminium Alloy, Anodised, Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified And As Directed. 33 M&Lpcc 1:2:4 Type B0 ( Using 12.5 Mm Graded Aggregate ) As In Hold Fast And Filling Of Steel Chowkhat Etc. Complete All As Specified And Directed 34 S&F For Mild Steel Flat Iron As In Hold Fast 25X6 Mm Confirming To Fe290 Gde E-165 Complete All As Specified And Directed 35 S&F In Repairs 110 Mm Bore Pvc ( Swr ) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors Complete All As Specified And As Directed 36 S&F In Repairs 75 Mm Bore Pvc ( Swr ) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors Complete All As Specified And As Directed 37 S&F For110 Mm Bore Pvc ( Swr ) Bends Any Radius Complete All As Specified And As Directed 38 S&F For75 Mm Bore Pvc ( Swr ) Bends Any Radius Complete All As Specified And As Directed 39 S&F For 110 Mm Bore Pvc ( Swr ) Junction Single, ( Single T ) Equal Or Unequal Complete All As Specified And As Directed 40 S&F For 75Mm Bore Pvc ( Swr ) Junction Single, ( Single T ) Equal Or Unequal Complete All As Specified And As Directed 41 Taking Up Or Down 20 Mm Bore Steel Tubing And Connections, Including Cleaning For Refixing Or Removal To Store Complete All As Specified And As Directed 42 Taking Up Or Down 25 To 32 Mm Bore Steel Tubing And Connections, Including Cleaning For Refixing Or Removal To Store Complete All As Specified And As Directed 43 Supply And Laying Of 20Mm Of Cpvc Pipes Sdr 11& Plain Cpvc Sdr 11 Fittings On Walls / Ceiling Or Laying In Floors Complete All As Specified.Tranches Complete All As Specified And Directed. 44 Supply And Laying Of 25Mm Of Cpvc Pipes Sdr 11& Plain Cpvc Sdr 11 Fittings On Walls / Ceiling Or Laying In Floors Complete All As Specified.Tranches Complete All As Specified And Directed. 45 S&F For 20Mm Dia Cpvc Brass Thread Elbow Complete All As Specified And As Directed. 46 S&F For 25Mm Dia Cpvc Brass Thread Elbow Complete All As Specified And As Directed. 47 S&F For20mm Dia Cpvc Brass Thread Tee Complete All As Specified And As Directed. 48 S&F For25mm Dia Cpvc Brass Thread Tee Complete All As Specified And As Directed. 49 S&F For 20Mm Cpvc Brass Thread Union Complete All As Specified And As Directed. 50 S&F For 25Mm Cpvc Brass Thread Union Complete All As Specified And As Directed. 51 S&F For 25Mm Cpvc Ball Valve Complete All As Specified And As Directed. 52 S&F For 25Mm Cpvc Tank Adopter Complete All As Specified And As Directed. 53 S&F For White Vitreous China Squatting Pan Orissa Pattern Of Size 580Mmx440 Mm White, With Integral Foot Rests Connected WithP Or S Trap And Flushing Pipe And Taking Out Old Wc & Connections Complete All As Specified And As Directed 54 S&F For Pvc Low Level Flushing Cistern 10 Litre Capacity, Valveless, Symphonic Action Type With Inlet, Ball Valve, Float And Handle Incl Bracket, Pvc Conection Pipe Andflush Pipe Of Polyethylene Of Low Or High Density Or Pvc. 32 Mm Dia Complete All As Specified And Directed 55 S&F For Pvc Connections 15Mm Size With Ptmt Nuts Of Length 600 Mm Complete All As Specified And As Directed 56 M&L Pvc ( Swr ) Floor Trap 75Mm Dia, Plain With Grating Including Jointing With Solvent Cement Including Disconnection Of Old Existing Trap, And Connected With Existing Water Pipe Complete All As Specified And Directed. 57 S&F For Brass Chromium Plated Shower Rose 125 Mm Sizefixing To Steel Pipe Or Union Complete All As Specified And As Directed 58 Pvc ( Swr ) Gully Trap 125 / 110 Mm, Setting And Jointing With Solvent Cement Complete All As Specified And As Directed 59 S&F In Repairs Soap Dish Vitreous China Coloured Approximate Size ( 160Mmx160mmx90mm ) Complete All As Specified And As Directed. 60 S&F For 600Mmx450mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete All As Specified And As Directed 61 S&F For Tubular Towel Rail, 20Mm Dia, D Type, 60Cm Long Brass Chromium Plated Between Flanges Complete All As Specified And As Directed 62 S&F In Repairs Vitreous China Wash Hand Basin White Flat Back Size 550X400mm Excluding Taps, Waste Chain And Plug And Porcelain Stopper Including Cutting For And Pinning In Ends Of Brackets Or Erecting Stand But Exclusive Of Fixing Of Supply And Waste Pipe Complete All As Specified And As Directed. 63 S&F In Repairs 32 Mm Waste Coupling Of Ptmt ( Half Or Full Threaded ) ( Minimum Weight 32Mm45Gms / 40Mm-60 Gms ) Complete All As Specified And As Directed 64 S&F For Pillar Taps Of Size 15Mm, Chromium Plated Fancy Type Cast Copper Alloy, With Capstan Heads, Screwed Down High Pressure, With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly Nuts Screwed For Iron Pipe Complete All As Specified And As Directed. 65 S&F In Repairs For Bib Taps Fancy Type Cp With Crutch Or Butterfly Handle Screwed Down, Screwed For Iron Pipe Or For Brass Ferule And Fixed Of Size 15Mm Bore In Repair Complete All As Specified And As Directed. 66 S&F For Vitreous China Bowl Urinal Flat Back, Size Of 465 X 355 X 265 Mm White ( Minimum ) , Including Providing And Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar:2, Securing Urinal To Plugs With And Including 60Mm Long Brassscrews, Pointing Around Urinal Back In Cement; Fixing Automatic Flushing Cistern With Brackets, Flush Pipe, Grating And Union For Discharge Pipe. ( Exclusive Of Fixing Supply Pipe To Flushing Cistern, Trap And Waste Pipe ) With Grating And Union For Discharge Pipe ( Excluding Flushing Cistern, Flush Pipe And Waste Pipe ) Complete All As Specified And As Directed. 67 S&F For 15Mmstop Valves ( Concealed Type ) , Cast Copper Alloy Fancy Type Chromium Plated, Long Sunk And Cup, Screwed Both Ends For Iron Pipe Or For Unions And Fixed Complete All As Specified And As Directed. 68 S&F For Anodised Aluminium Ventilator Shutters, Side Hung Type Without Sash Bars, Aluminium Sections Weighing 0.55 Kg / M Including Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws, Anodised Aluminium Fittings Such As Peg Stays 150Mm Long ( 1 No. ) . Hinges Type B-21 100Mm Long ( 2 No. ) Suitable Handle ( 1 No. ) Complete All As Specified And As Directed 69 M&L For Providing Precast Cement Concrete Manhole Covers, Type B1 1:2:4 ( 20 Mm Graded Aggregate ) Set In Cement Mortar 1:4 Complete All As Specified And As Directed 70 M&L For Mild Steel Tmt Bars 10 Mm Dia And Over , Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9 Mm Dia Or Securing With Clips Complete All As Specified And As Directed. 71 S&F In Repair 15Mm Dia Angle Stop Cock With Wall Flange All As Specified And Directed. ( Cat Part No G1807a1 ) Complete All As Specified And As Directed. 72 M&L Water Proofing Treatment On Rcc Roof Etc. Comprising With The Following Operation & As Specified Herein Below:- ( A ) M&L For 15 Mm Thick Cement Mortar In 1:4 Finished Even And Smooth. ( B ) Preparing & Cleaning Of Fully Dried Cement Plastered Surface. ( C ) Applying One Coat Of Cold Bituminous Primer To The Plastered Surface @ 0.25 Litres Per Sqm Conforming Is-3384. ( D ) A Layer Of App Based Polymeric Membrane Membrane 3Mm Thick ( Minimum ) Weighing 3.5 Kg Per Sqm Reinforced With Polyster Non Woven Fabric ( Weighing Not Less Than 160 Gms / Sqm ) Shall Be Applied Over Bituminous Primer As Specified Above.Application Of Polymeric Membrane Shall Be By Torch Application. The Over Lap Shall Be Minimum 100 Mm On Transverse Direction And 75 Mm In Longitudinal Direction. ( E ) One Coat Of Aluminium Paint Over App Membrane @0.11Kg / Sqm.Note:-Prior To Execution Of The App Membrane Works, Leak Proof Test Shall Be Done By Ponding Water On Roof Slab To Minimum Depth Of 25 Mm. The Entire Roof Slab Shall Be Flooded With Water For 48 Hours. The Necessary Barrier Shall Be Made To Make Feasible To Stagnate Water For 48 Hours On Roof Slab. 73 Supply, Installation, Commissioning And Testing Of Step Down Transformer Outdoor Type, Ht 11 Kv Ac 3 Phase, Lt 433 V, 50 Hz Delta / Star Connected Vector Group Dyn-11, Delta / Star Connection, Onan Cooling, Double Copper Wound, Off Load Tap Changing Device On Ht Side To Vary Secondary Voltage From Minus 7.5% To Plus 7.5% In Steps Of 2.5% Continuous Rating Of Capacity 500 Kva Incl Cable Box On Ht Side And On Lt Size.The Transformer Shall Confirm To Is:1180 ( Part-I ) 2014 And Complete With All Standard Fittings And Accessories, Gauges Including First Fill Of Transformer Oil Conforming To Is:335 Etc., All As Specified And Directed.Make : Cromptron Greaves / Indian Transformers / Voltamp / Abb / Alstom / Siemens 74 Supply, Laying, Testing And Commissioning Of The Ht 11Kv Xlpe Insulated Armoured Aluminium Conductor 3 Core 95 Sqmm Cable All As Specified And Directed.Make : Havels / Polycab / Finolex 75 Supply Laying And Testing Cable Pvc Insulated Screened Pvc Bedded Galvanized Strip Or Wire Armored Electric Power Cable ( Heavy ) Duty With Stranded Aluminium Conductor, 1100 Volt Grade Of Size 3.5 Core 400 Sqmm Cable All As Specified And Directed.Make: Havells / Polycab / Finolex 76 Supply Laying And Testing Cable Pvc Insulated Screened Pvc Bedded Galvanized Strip Or Wire Armored Electric Power Cable ( Heavy ) Duty With Stranded Aluminium Conductor, 1100 Volt Grade Of Size 3.5 Core 150 Sqmm Cable All As Specified And Directed.Make: Havells / Polycab / Finolex 77 Supply And Making New Ht End Joint With 11Kv Heat Shrinkable End Joining Kit Outdoor Type 3 Core 95 Sqmm Xlpe Aluminium Conductor Outdoor Type All As Specified And Directed. Make :-3M / Repl / Rachem 78 Excavation In Trenches In Hard / Dense Soil N.Exc 1.5 Mtr Wide And N.Exc 1.5 Mtr Depth And Getting Out Pole Foundation / Cable Trench Complete All As Specified And Directed. 79 Returning, Filling In Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm Thick Complete All As Specified And Directed. 80 Removing Surplus Excavated Material Not Exc 50 Mtrs And Depositing Where Directed At A Level Not Exc 1.5 Mtr Above The Starting Point Complete All As Specified And Directed. 81 Supply And Providing Sand Cushioning With Dry Clean Sand 8 Cm Below Cable And 15 Cm Above The Cable Complete All As Specified And Directed. Note : Punned Thickness Shall Be Measured For The Purpose Of Payments. 82 Supply And Laying Fly Ash Bricksin Trenches For Cable Protection With Length Of Brick Perpendicular To Length Of Cable Complete All As Specified And Directed. 83 Boring Of Holes Horizontally For Laying Of Pipe Not Less Than 100 Mm Dia ( Min Depth 0.90 Mtr To 0.120Mtr From Top Level ) Under Road, Hardstanding By Trench Less Technology For Passing Cable Through Pipe With Mechanical / Hydraulic / Compresser Pressure Pump Machine System Throughly To The Surface Of Roadcan Not Be Disturbed Or Cracked All As Specified And Directed. 84 Material And Labour For Filling The Road / Hard Standings Cut For Laying Cable With Pcc 1:2:4, Type B2, Using 40 Mm Graded Stone Aggregate And Finishing The Surface Even And Smooth Without Using Extra Cement All As Specified And Directed. 85 Earthing Complete With Galvanised Steel Earth Plate Electrode 60Cmx60cmx6mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Below Normal Ground Level ) With Top Edge Of Plate Not Less Than 1.5 Mtr Below Ground Level, Connecting To Galvanised Iron Strip 32Mm X 6Mm ( As Earth Lead Strip ) , By Means Of Bolt, Nuts, Check Nuts And Washer Of Gi And Gi Strip Protected By Provision Of Gi Pipe Light Grade, 40Mm Bore Upto Test Point Including Provn Of Concrete Pit In Pcc ( 1:2:4 ) Type B-1 Using 20Mm Graded Crushed Stone Aggregates With 40Mm Thick Cover Of Rcc ( 1:2:4 ) Reinforced With Xpm ( Weight Not Less Than 4 Kg / Sqm ) And Frame Of Angle Iron 25 X 25 X 3 Mm With Lugs 2 Nos And With 6Mm Dia Ms Bar Handle Made To Shape, Gi Medium Grade 20Mm Bore Pipe For Watering Perforated At Bottom 1.75 Metres Long Placed On Top Edge Of Earth Plate, Common Salt And Charcoal Filling, Test Point Made Out Of Phosphorous Bronze With Fixingarrangement, Funnel, Wire Mesh And Earth Work In Hard / Dense Soil, Returning Filling In And Removal Of Surplus Soil To A Distance Not Exceeding 50 Mtr, All As Per Electrical Plate No 3 Of Ssr 2009 Part-I And Connection To Earth Test Point All As Specified And Testing On Completion.Note :- Item Of Earthing Includes The Cost Of 7.5 Metre Long Galvanised Iron Strip 32Mm X 6Mm Size And Protection Pipe Of 40 Mm Bore Galvanised Iron Light Grade. 86 Supply, Installation, Commissioning And Testing Of Factory Made Cpri Approved Out-Door Type Dust & Vermin Proof Lt Panel Of 1.60 M Length, 0.5 M Width & 1.40 M Height To Be Fabricated Verticallyusing 50X50x5 Mm Angle Iron Frame And Intermediate Partitions With Base Mounting On 70X4mm Ismc And Using 3 Mm Thick Ms Sheet With Frp Coating All Over Canopy, Body Front And Back Doors With Hinges Andlocking Arrnagmentsand 2 Mm Thick Ms Sheet For Bus Bar Cover, Panel, Partitions And Cable Entry Covers At Bottom Side Duly Painted With Two Coat Of Synthetic Enamel Paint Over A Coat Of Redoxide Primer To Entire Panel And With Control Wiringcompletewith 1.5 Sq Mm Frls Copper Cable And 6A Mcb For Meter, Breaker Control Supply And Indication Lamps And Provision To Accommodate The Following All As Specified And Directed By Engineer-In-Charge : ( A ) Copper Bus Bar Of 1200A Current Carring Capacity For Main Bus And 600A Capacity Forneutral ( B ) Copper Bus Bar Links With Rated Current Carrying Capacity For Out Going MccbS Cables Connections ( C ) Digital Ammeter & Voltmeter For Incoming ( D ) Led Indication Lamps For Ryb For Incoming Indication ( E ) 800A, 4 Poleacb-1 No As Incommer And 630 A, 4 Pole Mccb-1 No And400 A Mccb-1 And 250A Mccb-1NoS As Outgoingnote : ( I ) Unit Rate Quoted Include Of Necessary Grouting / Chipping Of Concrete And Anchor Fastners And Providing Necessary Pcc Foundation To Fix The Lt Panel. ( Ii ) Digital Ammeter, Voltmeter, Led Lamps, Cts, Acb , MccbS And Copper Bus Bar Will Be Measured And Paid For Under Relevent Items. 87 Supply & Fixing Of Out-Door Type Dust & Vermin Proof Lt Panel Of 1.6 M Length, 0.5 M Width & 1.40 M Height To Be Fabricated Vertically By Using 50X50x5 Mm Angle Iron Frame And Intermediate Partitions With Base Mounting On 70X4mm Ismc And Using 3 Mm Thick Ms Sheet With Frp Coating All Over Canopy, Body Front And Back Doors With Hinges Andlocking Arrangementsand 2 Mm Thick Ms Sheet For Bus Bar Cover, Panel, Partitions And Withcable Entry Covers At Bottom Side Duly Painted With Two Coat Of Synthetic Enamel Paint Over A Coat Of Redoxide Primer To Entire Panel And With Control Wiring To Complete Lt Panel With 1.5 Sq Mm Frls Copper Cable And 6 A Mcb For Meters, Breaker Control Supply And Indication Lamps And Provision To Accommodate The Following All As Specified And Directed By Engineer-In-Charge : ( A ) Copper Bus Bar Of 800A Current Carring Capacity For Main Bus And 400A Capacity Forneutral ( B ) Copper Bus Bar Links With Rated Current Carrying Capacity For Out Going MccbS Cables Connections ( C ) Digital Ammeter & Voltmeter For Incoming ( D ) Led Indication Lamps For Ryb For Incoming Indication ( E ) 400A Mccb-1 No As Incommer And 250 A Mccb-1 No And200 A Mccb-1 And 200A Mccb-1NoS As Outgoingnote : ( I ) Unit Rate Quoted Included For Necessary Grouting / Chipping Of Concrete And Anchor Fastners And Providing Necessary Pcc Foundation To Fix The Lt Panel. ( Ii ) Digital Ammeter, Voltmeter, Led Lamps, Cts, MccbS And Copper Bus Bar Will Be Measured And Paid For Under Relevent Items. 88 Supply, Install, Test And Commissioning Of Lt Acb 4 Pole Of 800A Rated Capacity, 50 Ka Breaking Capacity , 415V, 50 Hz, Manual Drawn Out Type And Manually Charged With Micro Processor Release Protection Sytem Aganist Over Current , Earth Fault And Short Circuit With 4 No + 4 Nc Auxilary Switch, Main Cts, Safety Shutter, Cradle Guard, Operating Handles Confirming To Iec 60947-2 Including Necessary Modification / Fabrication To The Existing Lt Panel, Bus Barto Fix The Acb All As Specified And Directed.Make : L&T / Schnider / Havells 89 Supply, Install, Test And Commissioning4 Pole Mccb Of 630 A Rated Capacity , 50 Ka Breaking Capacity, 415 V, 50 Hz Ac Supply Of With Adjustable Thermal And Magnetic Settings, Extendable Rotaty Handle And Spreader Terminals With Extension Linksincluding Necessary Modification / Fabrication To The Existing Lt Pannelto Fix The Mccb And All As Specified And Directed.Make : L&T / Schnider / Havells 90 All As Per Item No 89 Above But Of Capacity 400A, 36Ka 91 All As Per Item No 89 Above But Of Capacity 250A , 36Ka 92 All As Per Item No 89 Above But Of Capacity 200A , 36Ka 93 Supply And Fix Electrolyte Tinned Copper Bus Bar Links With Pvc Sleeves Of Rating 200A To 1600A Including Bending And Drilling Of Holes As Required And Fixing In Lt Panels All As Specified And Directed. 94 Supply, Fix, Test And Commissioning Digital Electronic Volt Meter ( 0-500 Volts Range ) Within Built Of In Selector Switch Suitable For Lt 415 V Panel Flush Pattern Square Type 96 Mm X 96 Mm With Adopter Including Wiring Complete All As Specified And Directed. 95 Supply, Fix, Test And Commissioning Digital Electronic Ammeter ( 0-1250 Amps Range ) With Inbuilt Of In Selector Switch Suitable For Lt 415 V Panel Flush Pattern Square Type 96 Mm X 96 Mm With Adopter Including Wiring Complete All As Specified And Directed. Make: L&T / Ae 96 Supply, Fix And Testing Indication Lamps ( Led Type ) Red, Yellow And Green In Colours Ofmonitor On Lt Panel Board Suitable For 240 V Ac Supply Including Providing Control Wiring Complete All As Specified And Directed. Make : L&T / Ae 97 Supply And Fix Current Transformer ( Ct ) Of 800 / 5 / 5A Amps Ratio Resin Cast Type Wound Ct To Be Fitted In Lt Panel Board And Necessary Control Connection Up To Ammeter Including Wiringall As Specified And Directed.Make: Kappa / Rishab 98 All As Per Item No97above But Of Capacity 630 / 5 / 5A 99 All As Per Item No97 Above But Of Capacity 400 / 5 / 5A 100 All As Per Item No97 Above But Of Capacity 250 / 200 / 5 / 5A

Key Value

Document Fees
INR 500 /-
EMD
INR 72000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:ADDN/ ALTN TO BLDG NO P-59 AND UPGRADATION OF EM EQUIPMENTS UNDER GE (I) GOS.
Sl. No. Item Description
1Taking down the Chowkhats or frames exc 1.5 sqm but n exc 4 sqm each(without taking off shutters from the frames) complete all as specified and as directed
2Taking down the Shutters of any description n exc 1 sqm each complete all as specified and as directed
3Demolition of brickwork or stone/ boulder masonry, built in Cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed
4M&L Brick work with modular fly ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed
5M&L for taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
6M&L for rendering 15 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement Mortar in 1:4 using water proofing compound in top layer (Water Proofing Compound measured separately) andfinished even and smooth (without using extra lime or cement) complete all as specified and directed.
7M&L for rendering 10 mm thick internal wall on fair faces of brick work or concrete surfaces in cement Mortar in 1:6 andfinished even and smooth (without using extra lime or cement)complete all as specified and directed.
8M&L for rendering 5 mm thick on ceiling in cement mortar 1:3 finished even & smooth without using extra cement complete all as specified and directed
9Supply only Liquid water proofing compound for external wall plastering (for 5 mm thick plastering) complete all as specified and directed
10M&L for preparaion of newly plasteredsurfaces of walls andfinishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)complete all as specified and as directed.
11M&L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and as directed.
12M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
13M&L for hardcore of broken stone or boulders guage n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
14M&L for 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) in subbase of floor etc complete all as specified and as directed.
15M&L for chequered cement concrete tiles 20cmX20cmX25mm thick, set, joined and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and directed.
16M&L for 40 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) in sub base finishing cement concrete surface even and smoothwithout using extra cement complete all as specified and as directed
17Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed
18M&L for Non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar in 1:6 for laying floor finishes complete all as specified and as directed
19M&L for Coloured Glazed ceramic tiles in vertical surface of size 450X 350X 7 mm thick over 10 mm thick back coat of cement mortar in 1:4set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed.
20Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
21M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate) in plinth protection, finishing cement concrete surface even and smoothwithout using extra cement complete all as specified and as directed
22M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade A complete all as specified and as directed
23M&L for 25 mm thick Cement concrete type B-0 1:2:4 (12.5 mm graded aggregate)complete all as specified and as directed
24Dismantling of water tank Capacity exc 500 not exc 1000 Ltrs and removing to store complete all as specified and as directed
25Hoisting and Fixing of rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 ltrs hoisted and fixed in position specified in SSR Part I complete all as specified and as directed.
26S&F for 20 mm bore, Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
27S&F for Factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing in SSR Part II 2010 complete all as specified and as directed
28S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing in SSR Part II 2010 complete all as specified and as directed
29S&F100 mm long Butt hinges, medium weight, cold rolled mild steel fixed to Chowkats complete all as specified and directed
30S&F Aluminium Handle 100 mm long cast type, anodised extruded fabricated type complete all as specified and as directed.
31S&F Aluminium anodised barrel tower bolts of extruded section 100 mm long complete all as specified and directed.
32S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
33M&LPCC 1:2:4 type B0 (using 12.5 mm graded aggregate) as in hold fast and filling of steel chowkhat etc. complete all as specified and directed
34S&F for mild steel flat iron as in hold fast 25x6 mm confirming to Fe290 Gde E-165 complete all as specified and directed
35S&F in repairs 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed
36S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed
37S&F for110 mm bore PVC (SWR) bends any radius complete all as specified and as directed
38S&F for75 mm bore PVC (SWR) bends any radius complete all as specified and as directed
39S&F for 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed
40S&F for 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed
41Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed
42Taking up or down 25 to 32 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed
43Supply and laying of 20mm of CPVC pipes SDR 11& Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.tranches complete all as specified and directed.
44Supply and laying of 25mm of CPVC pipes SDR 11& Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.tranches complete all as specified and directed.
45S&F for 20mm dia CPVC Brass thread elbow complete all as specified and as directed.
46S&F for 25mm dia CPVC Brass thread elbow complete all as specified and as directed.
47S&F for20mm dia CPVC Brass thread Tee complete all as specified and as directed.
48S&F for25mm dia CPVC Brass thread Tee complete all as specified and as directed.
49S&F for 20mm CPVC Brass thread union complete all as specified and as directed.
50S&F for 25mm CPVC Brass thread union complete all as specified and as directed.
51S&F for 25mm CPVC ball valve complete all as specified and as directed.
52S&F for 25mm CPVC tank adopter complete all as specified and as directed.
53S&F for white vitreous china squatting pan orissa pattern of size 580mmx440 mm white, with integral foot rests connected with"P" or "S" trap and flushing pipe and taking out old WC & connections complete all as specified and as directed
54S&F for PVC low level flushing cistern 10 litre capacity, valveless, symphonic action type with inlet, ball valve, float and handle incl bracket, PVC conection pipe andflush pipe of polyethylene of low or high density or PVC. 32 mm dia complete all as specified and directed
55S&F for PVC connections 15mm size with PTMT nuts of length 600 mm complete all as specified and as directed
56M&L PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement including disconnection of old existing trap, and connected with existing water pipe complete all as specified and directed.
57S&F for Brass chromium plated shower rose 125 mm sizefixing to steel pipe or union complete all as specified and as directed
58PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed
59S&F in repairs soap dish vitreous china coloured approximate size (160mmx160mmx90mm) complete all as specified and as directed.
60S&F for 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed
61S&F for Tubular towel rail, 20mm dia, D type, 60cm long Brass Chromium plated between flanges complete all as specified and as directed
62S&F in repairs vitreous china wash hand basin white flat back size 550x400mm excluding taps, waste chain and plug and porcelain stopper including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and as directed.
63S&F in repairs 32 mm Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm45gms/40mm-60 gms) complete all as specified and as directed
64S&F for pillar taps of size 15mm, chromium plated fancy type cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered "Hot" or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed.
65S&F in repairs for bib taps fancy type CP with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule and fixed of size 15mm bore in repair complete all as specified and as directed.
66S&F for Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum),including providing and fixing plugs, bedding urinal against wall in cement mortar:2, securing urinal to plugs with and including 60mm long brassscrews, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed.
67S&F for 15mmstop valves(concealed type),cast copper alloy fancy type chromium plated, long sunk and cup, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
68S&F for Anodised aluminium ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed
69M&L for Providing precast cement concrete manhole covers, Type B1 1:2:4 (20 mm graded aggregate) set in cement mortar 1:4 complete all as specified and as directed
70M&L for Mild steel TMT bars 10 mm dia and over ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
71S&F in repair 15mm dia Angle Stop Cock with wall flange all as specified and directed. (Cat Part No G1807A1) complete all as specified and as directed.
72M&L Water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:-(a) M&L for 15 mm thick cement mortar in 1:4 finished even and smooth.(b) Preparing & cleaning of fully dried cement plastered surface. (c) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 litres per sqm conforming IS-3384. (d) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric(weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above.Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction.(e) One coat of aluminium paint over APP membrane @0.11Kg/Sqm.Note:-Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab.
73Supply,Installation,commissioning and testing of Step down transformer outdoor type, HT 11 KV AC 3 phase, LT 433 V, 50 Hz Delta/Star connected vector group Dyn-11, Delta / Star connection, ONAN cooling, double copper wound, off load tap changing device on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5% continuous rating of capacity 500 KVA incl cable box on HT side and on LT size.The transformer shall confirm to IS:1180 (Part-I) 2014 and complete with all standard fittings and accessories, gauges including first fill of transformer oil conforming to IS:335 etc., all as specified and directed. Make : Cromptron Greaves /Indian transformers/ Voltamp/ ABB/ALSTOM/SIEMENS
74Supply, laying, testing and commissioning of the HT 11KV XLPE insulated armoured aluminium conductor 3 core 95 sqmm cable all as specified and directed.Make : Havels/Polycab/Finolex
75Supply laying and testing cable PVC insulated screened PVC bedded galvanized strip or wire armored electric power cable ( heavy) duty with stranded aluminium conductor, 1100 volt grade of size 3.5 core 400 Sqmm cable all as specified and directed. Make: Havells/Polycab/Finolex
76Supply laying and testing cable PVC insulated screened PVC bedded galvanized strip or wire armored electric power cable ( heavy) duty with stranded aluminium conductor, 1100 volt grade of size 3.5 core 150 Sqmm cable all as specified and directed. Make: Havells/Polycab/Finolex
77Supply and making new HT end joint with 11KV heat shrinkable end joining kit outdoor type 3 core 95 sqmm XLPE aluminium conductor outdoor type all as specified and directed. Make :-3M/REPL/Rachem
78Excavation in trenches in hard/dense soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out pole foundation/cable trench complete all as specified and directed.
79Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
80Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
81Supply and providing sand cushioning with dry clean sand 8 cm below cable and 15 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments.
82Supply and laying Fly ash bricksin trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
83Boring of holes horizontally for laying of pipe not less than 100 mm dia (min depth 0.90 mtr to 0.120mtr from top level) under road, hardstanding by trench less technology for passing cable through pipe with mechanical/hydraulic/compresser pressure pump machine system throughly to the surface of roadcan not be disturbed or cracked all as specified and directed.
84Material and labour for filling the road / hard standings cut for laying cable with PCC 1:2:4, type B2, using 40 mm graded stone aggregate and finishing the surface even and smooth without using extra cement all as specified and directed.
85Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to galvanised iron strip 32mm X 6mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of GI and GI strip protected by provision of GI pipe light grade, 40mm bore upto test point including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25 x 25 x 3 mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 metres long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 metre long galvanised iron strip 32mm X 6mm size and protection pipe of 40 mm bore galvanised iron light grade.
86Supply,Installation,Commissioning and testing of factory made CPRI approved out-door type dust & vermin proof LT panel of 1.60 M length, 0.5 M width & 1.40 M height to be fabricated verticallyusing 50x50x5 mm angle iron frame and intermediate partitions with base mounting on 70x4mm ISMC and using 3 mm thick MS sheet with FRP Coating all over canopy, body front and back doors with hinges andlocking arrnagmentsand 2 mm thick MS sheet for bus bar cover, panel, partitions and cable entry covers at bottom side duly painted with two coat of synthetic enamel paint over a coat of redoxide primer to entire panel and with control wiringcompletewith 1.5 sq mm FRLS copper cable and 6A MCB for meter, breaker control supply and indication lamps and provision to accommodate the following all as specified and directed by Engineer-in-Charge : (a) Copper bus bar of 1200A current carring capacity for main bus and 600A capacity forneutral (b) Copper bus bar links with rated current carrying capacity for out going MCCB"s cables connections (c) Digital ammeter & voltmeter for incoming (d)LED indication lamps for RYB for incoming indication (e) 800A,4 poleACB-1 No as incommer and 630 A,4 pole MCCB-1 No and400 A MCCB-1 and 250A MCCB-1No"s as outgoing Note : (i)Unit rate quoted include of necessary grouting / chipping of concrete and Anchor fastners and providing necessary PCC foundation to fix the LT Panel. (ii) Digital ammeter, voltmeter, LED lamps, CTs, ACB ,MCCB"s and Copper bus bar will be measured and paid for under relevent items.
87Supply & fixing of out-door type dust & vermin proof LT panel of 1.6 M length, 0.5 M width & 1.40 M height to be fabricated vertically by using 50x50x5 mm angle iron frame and intermediate partitions with base mounting on 70x4mm ISMC and using 3 mm thick MS sheet with FRP Coating all over canopy, body front and back doors with hinges andlocking arrangementsand 2 mm thick MS sheet for bus bar cover, panel, partitions and withcable entry covers at bottom side duly painted with two coat of synthetic enamel paint over a coat of redoxide primer to entire panel and with control wiring to complete LT panel with 1.5 sq mm FRLS copper cable and 6 A MCB for meters, breaker control supply and indication lamps and provision to accommodate the following all as specified and directed by Engineer-in-Charge : (a) Copper bus bar of 800A current carring capacity for main bus and 400A capacity forneutral (b) Copper bus bar links with rated current carrying capacity for out going MCCB"s cables connections (c) Digital ammeter & voltmeter for incoming (d)LED indication lamps for RYB for incoming indication (e) 400A MCCB-1 No as incommer and 250 A MCCB-1 No and200 A MCCB-1 and 200A MCCB-1No"s as outgoing Note : (i)Unit rate quoted included for necessary grouting / chipping of concrete and Anchor fastners and providing necessary PCC foundation to fix the LT Panel. (ii) Digital ammeter, voltmeter, LED lamps, CTs, MCCB"s and Copper bus bar will be measured and paid for under relevent items.
88Supply,Install,test and commissioning of LT ACB 4 pole of 800A rated capacity, 50 KA breaking capacity , 415V, 50 Hz, manual drawn out type and manually charged with micro processor release protection sytem aganist over current ,earth fault and short circuit with 4 NO + 4 NC auxilary switch, main CTs, safety shutter, cradle guard, operating handles confirming to IEC 60947-2 including necessary modification /fabrication to the existing LT panel, bus barto fix the ACB all as specified and directed. Make : L&T/Schnider/Havells
89Supply, install, test and commissioning4 pole MCCB of 630 A rated capacity ,50 KA breaking capacity, 415 V, 50 Hz AC supply of with adjustable thermal and magnetic settings, extendable rotaty handle and spreader terminals with extension linksincluding necessary modification /fabrication to the existing LT pannelto fix the MCCB and all as specified and directed. Make : L&T/Schnider/Havells
90All as per item No 89 above but of capacity 400A,36KA
91All as per item No 89 above but of capacity 250A ,36KA
92All as per item No 89 above but of capacity 200A ,36KA
93Supply and fix electrolyte tinned copper bus bar links with PVC sleeves of rating 200A to 1600A including bending and drilling of holes as required and fixing in LT panels all as specified and directed.
94Supply, fix, test and commissioning digital electronic Volt meter (0-500 volts range) within built of in selector switch suitable for LT 415 V panel flush pattern square type 96 mm x 96 mm with adopter including wiring complete all as specified and directed.
95Supply, fix, test and commissioning digital electronic ammeter (0-1250 amps range)with inbuilt of in selector switch suitable for LT 415 V panel flush pattern square type 96 mm x 96 mm with adopter including wiring complete all as specified and directed. Make: L&T/AE
96Supply, fix and testing indication lamps (LED type) red, yellow and green in colours ofmonitor on LT panel board suitable for 240 V AC supply including providing control wiring complete all as specified and directed. Make : L&T/AE
97Supply and fix current transformer (CT) of 800/5/5A Amps ratio resin cast type wound CT to be fitted in LT panel board and necessary control connection up to ammeter including wiringall as specified and directed. Make: Kappa/Rishab
98All as per item No97above but of capacity 630/5/5A
99All as per item No97 above but of capacity 400/5/5A
100All as per item No97 above but of capacity 250/200/5/5A
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail