Tender For Special Repairs To Certain Bldgs And Communityhall (P-75) At Afac Coimbatore, coimbatore-Tamil Nadu

Military Engineer Services-MES has published Tender For Special Repairs To Certain Bldgs And Communityhall (P-75) At Afac Coimbatore. Submission Date for this Tender is 27-11-2023. Building Work Tenders in coimbatore Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

40426653
Corrigendum : Tender For Special Repairs To Certain Bldgs And Communityhall (P-75) At Afac Coimbatore
Open Tender
Indian
Tamil Nadu
coimbatore
27-11-2023

Tender Details

Tender For Special Repairs To Certain Bldgs And Communityhall ( P-75 ) At Afac Coimbatore; 1 Removal Of Plants / Shrubs Grown On Walls / Slabs / Beams By Making Holes Or Demolition Of Concrete Etc And Including Applying Suitable Chemical For Killing The Roots Of Plants, Filling Of Holes With Concreteand Making Good Complete All As Specified And Directed. 2 Chipping / Removing Loose Concrete In Cloumns / Beams / Chajjas / Roof Slab Etc. Up To Reinforcement Bars Without Damaging The Reinforcement, Removing All The Loose Material And To Make All The Exposedsurface Free From Dust And All Impurities Etc Complete Allspecified And Directed. 3 Removing Corrosion Of Steel Reinforcement By Mechanical Means Like Wire Brushing, Chipping To Remove Loose Rust And Then Applying Rust Removal Solution Reebaklens Rr Of Fosroc / Sika Rust Off 100 / Equivalent In Bostic India Ltd By Using Brush Application, Leaving The Surface For At Least 15 To 30 Minutes, Then Removing Loose Materials By Scrubbing Or With Brush And Applying Anti Corrosive Coating To Reinforcement Nitozinc Primer Of Fosroc / Sika Friazinc R / Equivalent In Bostic India Ltd , All As Recommended By Product Manufacturer. 4 Providing And Applying One Coat Of Structural Grade Epoxy Coat By Brush Of Approved Make . Mixing Of Two Components Will Be As Directed By Manufacturer .Application Shall Be Provided Not More Than 5 Hours Before Application Of Micro Concrete / Polymer Mortar Etc Complete All As Specified By The Manufacturer.Make:- Nitobond Ep Of Fosrock / Sikdur 32Lp / Equivalent In Bostic India Ltd 5 Providing And Applying N Exc 40 Mm Thick ( In Layers Of Each 10Mm Thick ) Shrinkage Controlled, Polymer Modified, Fibre Reinforced Cementitious Repair Mortar Renderoc Sp 40 Of Fosroc / Sika Plastocrete Plus / Equivalent In Bostic India Ltd, Mixed With Water In A Water & Powder Ratio 0.18 In Ceiling Of Roof Slab / Chajjas / Beams / Parapet Walls Etc.Note:- Quoted Tate Is Deemed To Be Inclusive Of Provideing Scaffolding For Working In Patches Upto A Height Of 15 Mtr Complete All As Specified And Directed. 6 Surface Grinding, Rounding Off All Edges To Minimum Of 25Mm Radius Andand Applying Nitowrap Cws 230 Of Fosrock ( Or ) Sika Wrap 230C, Uni Directional, High Strength, Light Weight, Non Corrosive Carbon Fiber Sheets Of All Around The Periphery Of Pier For Entitre Height Of Pier.The Frp Fabric Used Shall Be Ofzero Degree Unidirectional Fibers Havingfiber Density Of 1.8 G / Cc And Shall Have Tensile Strength > 4900 Mpa ; Tensile Modulous > 230 Gpa And Ultimate Elongation Of 2.1%. The Substrate Shall Be Primed With Nitowrap 30 Epoxy Primer &Nitowrap 410 Impregnating Resin Saturant Shall Be Used For Saturating The Fibers.Saturant Used Shall Have Tensile Strength Of >30 Mpa; Elongation > 2% ; Flexural Strength > 30 Mpa ; Tensile Modulous > 2400 Mpa & Flexural Modulous > 1700 Mpa When Tested As Per Astm D638 Type I And Astm D 790 & Glass Transition Temperature > 50 Deg Celcius As Per Astm E 1356. The Adhesion Of The Entire System ( Frp Sheet, Saturant And Primer Combined ) With Concrete Shall Be > 3.5 Mpa With Concrete Failure As Per Astm D 4541.Wrapping The Cfrp Fabric To Rcc Member Atdesired Orientation Using Tamping Rollers To Avoid Any Airvoids Etc. And Sprinkling Sand Over It As Per Direction And Satisfaction Of Engineer-In-Charge, Etc, Complete. Product Used Shall Have Ce ( Ce-29842 ) Marking And Compliance According To Construction Products Directive 89 / 106 / Eec ( Cpd ) 7 Demolition Of Rcc Roofs, Floors ( Other Than Ground Floors ) , Beams, Staircases, Landing, Chajjas And Similar Suspended Work . 8 M&L For Flat Form Work For Rough Finished Surfaces To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Sup- Ports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. 9 M&L For Flat Form Work For Rough Finished Surfaces To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work; Not Exceeding 200Mm Thick ( Horizontal Or Sloping ) . 10 M&L For Rcc M-25 In Beams, Cantilevers, Bressummers, Lintels Over 1.5M Span 11 M&L For Rcc M-25 In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like 12 S&F Mild Steel Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips 13 All As Above Item But 5Mm Dia And Over Upto And Including 10Mm Dia In Stirrups, Spacers And Binders 14 Taking Down Existing Roof Treatment Includingscreed Bed , App Membrane Etc Upto Mother Slab Of Roof And Cleaning With Wire Brushe And Water Complete , Including Shifting Of Mulba From Roof To Ground Floor For Futher Disposal All As Specified And Directed By E-I-C. 15 M&L For Pcc 1:1.5:3 Type B0 Admixed With Nitobond Sbr Of Fosrock ( Or ) Equivalent Products In Sika / Asain Paints @ 2% By Weight Of Cement In Roof Slabs For Filling Up Spots Of Loose Screed / Concrete , Complete All As Specified And Directed By E-I-C. 16 Supply And Application Of Single Component, Seamless, Spray Applied, Hybrid Elastomeric Pu Based Material I.E Nitoproof 725 Of Fosroc Chemicals ( Or ) Sikalastic 590 Of Sika India Pvt Ltd ( Or ) Equivalent In Any Approved Make As Approved By Ge Over A Coat Of Primer I.E Nitoproof Wb Primer Of Fosroc Chemicals ( Or ) Diluted Sikalastic 590 Of Sika India Pvt Ltd ( Or ) Equivalent In Any Approved Make As Approved By Ge, All As Recommended By Manufacturer Ans As Specified.Note:- ( I ) Average Minimum Dftof Pu Based Material Shall Be 1Mm And Shall Be Applied By Using A Graco Pump. ( Ii ) Pu Based Material Shall Process The Following Properties Solids By Volume -65%, Tensile Strength Astm D412-1.75Mpa, Density 1.3 G / Ml, Elongation Astm D-412-350%, Adhesion To Substrate Concrete-1.9Mpa, Resistance To Water-10M Pressure. ( Iii ) Rate Are Deemed To Be Include For Cleaning And Preparation Of Surface To Receive Pu Water Proofing System Including Filling Of Cracks With Cementitious Repair Mortars I.E Renderoc Cs Of Fosrock Chemicals ( Or ) Equivalent Of Approved Make. ( Iii ) Work Shall Be Got Carried Out By Authorised Applicator Of The Manufacturer And It Shall Be Got Approved By The Ge Before Progressing The Work. ( Iv ) 10 Years Of Guarantee Shall Be Provided And Security Amount Shall Be Deposited As Speicified In Tender Documents. 17 Taking Down Cement Plaster On Brick Or Stone Walls, Ceilings, Etc Including Racking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc 18 M & Lrendering In Cm 1:3, 5Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces On Ceiling Complete All As Specified. 19 M & L For Preparation Of Newlyplastered Surfaces And Applying Threecoats Of White Washon Ceiling.Surface All As Specified. 20 M&L For Rendering With Wpc In Cm 1:4, 15Mm Thick On Othe Thanfair Faces Of Brick Work Or Concrete Surfaces All As Specified And Directed. Note : Wpc Shall Be Measured And Paid Separately 21 M&L For Rendering In Cm 1:6, 10Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces All As Specified And Directed. 22 M & L Preparation Newly Plasteredof Wall Surfaces And Applyingtwo Coats Of Cement Base Paint Over A Coat Of Primerall As Specified And As Directed Directed By Engr-In-Charge. 23 M & L Prepation Of Newly Plastered Wall Surfaces And Applyingtwo Coats Of Distemper Oil Emulsion Over Over A Coat Of Primerall As Specified And As Directed Directed By Engr-In-Charge. 24 Supply Only Intergral Waterproofing Compound 25 Preparation Of Old Treatedof Wall Surfaces And Applyingone Coat Of Cement Base Paintall As Specified And As Directed Directed By Engr-In-Charge.Note:- ( I ) This Item Of Work Shall Be Executed Upto A Height Of 30 Mtr Height Buildings / Structures / Rcc Ohts. ( Ii ) Scaffolding Required To Be Done For Executing The Work Above The Normal Heights As Specified In Ssr Pt-Ii Shall Be Measured And Paid Separately Under A Separate Item For The Whole Building / Structure. 26 M & L For Applyingone Coats Of Distemper Oil Emulsion On Old Treated / Decorated Surfaces Of Wall Including Preparation Of Wall All As Specified And As Directed Directed By Engr-In-Charge. 27 M & L For Preparation Of Oldplastered Surfaces And Applying Twocoats Of White Washon Ceiling.Surface All As Specified. 28 M & L For Preparation Of Oldtreated Wall Surfaces And Applying Twocoats Of White Washall As Specified. 29 Preparing Old Surface Of Wood And Wood Based Material Of Any Description Not Otherwise Described Over 10Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint. 30 Preparing Old Surface Of Steel And Steel Based Material Of Any Description Not Otherwise Described Over 10Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint. 31 Providing & Fixing Double Steel Scaffolding System ( Cup Lock Type ) On The Exterior Side Of The Building / Structure, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement At Site, Made With 40Mm Dia Ms Tube, Placed 1.5Mtr C / C ( Maximum ) , Horizantal & Vertical Ms Tubes Jointed With Cup & Lock System In The Scaffolding For Working Platform Etc Amd Maintaining It In A Serviceable Condition For Execution Of Work And Removing It Thereafter. The Scaffolding System Shall Be Stiffned With Bracings, Runners, Connecting With Building Etc Wherever Required To Ensure Safety Of Workmen All As Directed By Engr-In-Charge.Note:- 1.Area Derived By Multiplying The Outer Most External Perimeter And Height Of The Building / Structure Shall Be Measured For Payment.2. The Payment Shall Be Made Only Once After Completion Of All External Items Of Work W.R.T The Building / Structure. 3. After Completion Of The Work The Material Of The Scaffolding Shall Be The Property Of The Contractor And Required To Be Removed From The Site. 32 Demolition Of Concrete In Above Ground Floors And Pavings Exc 15 Cm Thick 33 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortor Bedding ( But Not Backing To Stone And Rubbish Off The Premises Complete All As Specified And Directed. 34 M & L For Non-Skid Coloured Ceramic Tiles 7 To 8Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.18 Sqm But Not Exceeding 0.38 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Surface All As Specified And As Directed By Engr-In-Charge.. 35 M & L For Non-Skid Coloured Ceramic Tiles 7 To 8Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.06 Sqm But Not Exceeding 0.11 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Surface All As Specified And As Directed By Engr-In-Charge.. 36 M & L Glazed Coloured Ceramic Tilesin Vertical Surface 350X250x7mm / 450X350x7mm Thickset And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Surface All As Specified And As Directed By Engr-In-Charge.. 37 M&Lfor Screed Bed Or Bedding Layer Of Mortor 15 Mmthick In Cm 1:6 For Laying Floor Finishes All As Specified And Directed. 38 M&L For Rendering 10Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces With Cm 1:4As In Backing Coat Of Skirting / Dado All As Specified And Directed. 39 M&L For Brick Work With Sub Class B Bricks, Old Size, Straight Or Curved On Plan Exceeding 6 Mtr Mean Radius And Built In Cement Mortar 1:6 Complete All As Specified And Directed. 40 Demolition Of Brickwork Or Stone / Boulder Masonry, Built Incement Mortar Including All Quoins, Arches, Pillars, Etc, But Excluding Ashlar Facings, Dressed Stonework And Precast Concrete Articles 41 Taking Down Chowkhats Or Frames With Shutter ( With Out Taking Off The Shutters From The Frames ) Size Not Exc 1.50 Sqm Each And All As Specified And Directed. 42 Taking Down Shutters Of Any Descriptionexc 1 Sqm And N Exc 2Sqm Each All As Specified And Directed. 43 S&F Iind Class Hard Wood , 35Mm Thickplain, Framed, Panelled Shutters ( Any Number Of Panels ) , With Panels Of Timber Flat On Both Sides ( Feather Edged ) , Or Of Veneered Particle Board Medium Density, Wood Particle Board With Commercial Face Veneers All As Specified And Directed. 44 S&F Iind Class Hard Wood, 35 Mm Thick Glazed And Skeletonshutter, Open Rebated And Prepared To Receive Glass , Gauge, Etc Without Sash Bars But Divided Into Squares, Edges Of Framing Plain Chamfered Or Rounded, Fitted With Cut And Mitred Beads For Securing Glass, Etc, Size Of Members Of Shutters As Specified In Ssr Part-I Section 8, Clause 8.24 ( A ) And Fitted To Chowkatscomplete All As Specified And As Directed By Engineer-In-Charge. 45 S & F Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Suplying And Fixing In Opening As Per Specification And Drawing Etc Complete All As Specified And As Directed By Engineer- In-Charge. 46 S & F Factory Made Solid Pvc Moulded Door Shutter With Wood Eps, 30Mm Thick , With 2, 4, Or 6 Raised Panel Design With 2Mm Thick Mouldedprelaminated Pvc Sheet On Both Facessupplying & Fixing In The Frame At Site As Per Specification & Drawing Etc Complete All As Specified And As Directed By Engineer-In-Charge. 47 Steel Windows With Side Hung Shutters Including Projecting Type Hinges With Steel Handle, And Steel Peg Stay, Complete With Glazing Bars, Dovetailed Or Welded . 48 Ditto, But Without Glazing Bars 49 S&F Mild Steel Work In Hold Fasts Etc And Similar Work Conforming To Fe-290 Gde E-165. 50 Preparing Surfaces Of Wood And Wood Based Materials, Steel And Iron Work , New Or Old , Treating Small Articles Such As Stop, Covers Gully Gratings, Hold Fasts Ends Of Posts, Back Of Chowkats Etc , Area N Exc 0.1 Sqm Each And Treated With Tar Or Coal Tar Black Paint. 51 M&L For Cement Concrete Type B1 1:2:4 ( 20Mm Graded Aggregate ) For Fixing Of Hold Fast, Including Finished To Match With Exiting Surfacesall As Specified And Directed. 52 S&F Iind Class Hard Wood, Small Fittings Such As Shaped Door And Window Stops And Like Articles N Exc 200 Cu Cm Each All As Specified And Directed. 53 S&F300mm Long Aluminium Alloy, Anodised Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast Aluminum Alloycomplete And All Asspecified And Directed 54 S & F Floor Door Stopper 140Mmlong With Cover Plate Of Aluminium Alloy Body And Tongue, Anodised, With Hard Drawn Steel Spring. Fixed In Floor 55 S&F100mm Long Butt Hinges, Medium Weight, Coldrolled Mild Steel And All Asspecified And Directed 56 S&F 150Mmaluminium Alloy , Anodised, Sliding Door Bolt With Hasp And Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts Of Extruded Sections Or Cast Aluminium Alloy All As Specified And As Directed. 57 S&F 150Mm Longaluminium Anodised Barrel Towers Bolts Of Extruded Section And All Asspecified And Directed 58 S&F 150Mm Extruded Aluminium Alloy Handles, Fabricated Type Anodised Asspecified And Directed 59 M&L For Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer Including Preparation Of New Wooden Surfaces All As Specified And Directed. 60 Framed Work Such As Grills, Gratings, Etc.. With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework Of Water Tanks And Similar Work Conforming To Fe.290.Gde-E-165 61 M&L For Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Including Preparation Of New Steel Surfaces All As Specified And Directed. 62 Supply Only3 Mm Figured Glass, Ordinary Quality , N Exc 0.5 Sqm In Each Glass All As Specified And Directed. 63 Supply Only Stainless Steel Wire Cloth 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Stell Wire Staples. 64 S&F In Repair Only4mm Sheet Glass, Ordinary Quality , N Exc 0.5 Sqm In Each Glass All As Specified And Directed. 65 S&F In Repair3 Mm Figured Glass, Ordinary Quality , N Exc 0.5 Sqm In Each Glass All As Specified And Directed. 66 S&F In Repair Stainless Steel Wire Cloth 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Stell Wire Staples. 67 Taking Up Or Down Steel Tubing And Connections, And Removing To Store For Taking In Account Of Credit For 15Mm Bore Complete All As Specified And Directed. 68 All As Per Itemabovebut For 20 Mm Bore 69 3-Layer Pp-R ( Polypropylene Random Copolymer ) Concealed Pipes / Un Concealed Pipes Sdr 7.4 ( Pn-16 ) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain And Brass Threaded Poly Propylene Random Fittings Fixed Complete To Walls / Ceilings Or Laid On Floors Of 16Mm Outer Dia Of Pipe All As Specified And As Directed 70 All As Per Item No 69 Above But 20Mm Dia 71 Taking Down & Refixing Ppr 15Mm / 16Mm Pipes 72 Taking Down & Refixing Ppr 20Mm 73 S&F In Repairs Vitreous China Wash Down Water Closet Pan ( Pedestal Pattern ) , White Including Seat Cover And Flush Pipe Etc Complete All As Per Specified And As Directed By Engineer-In-Charge. 74 S & F In Repairs Pvc Valveless, Syphonic Action Type, Flushing Cistern Of 10 Ltrs Capacity , Low Level , White, With Inlet , Ball Valve, Float And Handle Including Brackets And Flush Pipe Etc Complete All As Specified And As Direted By Engineer-In-Charge. 75 S& F In Repair Vitreous China Wash Basin, White, Flat Back, Size 450X300mm Excluding Taps, Waste, Chain And Plug And Porcelain Stopper But Including Brackets Including 32Mm Ptmt Waste Cupling , Complete All As Specifed And Directed. 76 S&F In Repairs Bib Taps, Brass Chromium Plated Fancy Type With Cruch Or Butterfly Handle Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule And Fixed For 15Mm Bore. 77 S&F In Repairs Two Way Bib Taps, Brass Chromium Plated Fancy Type With Cruch Or Butterfly Handle Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule And Fixed For 15Mm Bore. 78 S&F In Repairs Pillar Taps Fancy Type Cast Copper Alloy, With Capstain Head, Chromium Plated Screwed Down High Pressure, With Long Shanks And Fly Nuts Screwed For Iron Pipe And Fixed 15 Mm Bore. 79 S & F Pvc Connections 15 Mm Size With Ptmt Nuts Of Length 450 Mm 80 S&F In Repairs Chromium Plated Angle Valves, Cast Copper Alloy, Screwed Down High Pressure With Crutch Or Butterfly Handles Screwed Both Ends For Iron Pipes Or For Unions And Fixed. 15 Mm Size. 81 S&F Brass Chromium Plated Health Faucet With Hand Held And Spring Operated Control Valve With Pvc Flexible Pipe Connection Of Suitable Length As Directed Fixed To 15 Mm Bore Pipe. 82 M & L 75Mm Dia For Pvc ( Swr ) Multi Floor Trap Ofwith Grating Including Jointing With Solvent Cement Etc Complete, 83 S & F In Repairs 110Mm Dia Pvc ( Swr ) Pipe Single Sockted In Any Length With Rubber Ring Joints Fixed To Wallwith Clamp Complete All As Specified And Directed. 84 S&F 110Mm Radius Pvc ( Swr ) Bendscomplete All As Specified And Directed. 85 S&F 110Mm Radius Pvc ( Swr ) Branch Piece, Single ( Single T ) Equal Or Unequal Complete All As Specified And Directed. 86 S & F In Repairs75mm Dia Pvc ( Swr ) Pipe Single Sockted In Any Length With Rubber Ring Joints Fixed To Wallwith Clamp Complete All As Specified And Directed. 87 S & F 50Mm Diaunplasticised Pvc Pipe Of Pressure Rating 10 Kgf / Cm2 Fixed Complete To Walls, Ceiling Or In Floors Etc Complete 88 M & L For 125 / 110Mm Dia Pvc ( Swr ) Gullytrap Including Setting Jointing With Solvent Cement Etc Complete, 89 S&F 110 Mm Borepvc ( Swr ) Vent Cowl 90 S&F 600Mm X 450Mm Bevelled Edge Looking Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed Towooden Plugs With Chromium Plated Brass Screws And Cup Washers. 91 Dismantling Of Pvc Water Tank 500 Ltr Capacity And Removing To Store 92 S&F Moulded Polyethylene 500 Ltr Water Tank Storage Tanks ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position Complete All As Specified And Directed By Engr-In-Charge. 93 S&F In Repairs 25 Mm Ball Brass Valves, High Pressure, With Polythene Float And Flynut Cimplete Screwed For Iron Pipe Or Brass Ferrule And Fixed Complete All As Specified And Directed. 94 M&L For Cement Concrete Type B1 1:4:8 ( 20Mm Graded Aggregate ) In Filling And Mass Concreteall As Specified And Directed. 95 M&L Forsand Cushioning Under Floor Or In Foundation Including Watering And Consolidation For Laying Of Interlocking Pavour Block. 96 Machine Pressed Precast Concrete Interlocking Paver Block Any Shape And Size Confirming To Is 15658-2006 Of 60 Mm Thickness, M-35 Grade With Grey Cement And No Pigments 97 Removalof Debris / Building Material Out Side The Campus Including Loading And Unloading, Etc To A Distance Exc 5Km But N Exc 10 Km Out Side The Md Land Complete All As Specified And Directed. Note:- Location And Permission Of Depositing The Building Materials / Debris Disposal Outside The Md Land Shall Rest With Contractor At His Own Arrangement. 98 Taking Down Chain Link Fencing Including Ms Straining Rods And Ms Flat Iron Strips All As Directed By Engr-In - Charge 99 Fixing Only Chain Link Fencing Including Line Wires Any Mesh Size And Type Of Standerds Rails Scraining Babs Etc Incl Permission O Binding Wire ( Note Supply Of Chain Link Will Be Measured Seperately ) . 100 Supply Only Chain Link Ms Galvanized Fencing Of Any Mesh Size And Type Note Fixing Shall Be Measured Under Serial Item No Here In Above. 101 M& L Hand Rails, Half Round Or Other Steel Section Or Core For Wooden Hand-Rail Straight Portion, Drilled And Countersunk For Balusters Running Bars, For Doors, Balusters, Nosing To Steps Including Embeding In Concrete And Screwing Etc. Wind Ties For Roof Including Securing Bolts;Posts And Struts In Fencingincluding Cutting Tops To Shape As Directed, Drilling Holes, Notching For Wire, Etc.; Flat Iron Fillets ( For Securing Wire Mesh Etc. ) Including All Necessary Drilling, Bolting Or Riveting, Etc., And Similar Work Conforming To Fe-290 Gde E-165 102 Tie Bars With Screwed Ends, Nuts, Washers And Mild Steel Plates For Walls, Chimneys, Roofs, Arches, Etc. King Rods And Straining Bolts Conforming To Fe- 290 Gde-E-165 103 Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For 104 Demolition Ofcement Concretein Below Or Above Ground Level And Paving Not Exc 15 Cm Thickness 105 M&L 25 Mm Thick Cement Concrete Type B-0, 1:2:4 ( 12.5 Mm Graded Aggregate ) As In Sub Base Of Floors Without Extra Cement All As Specified. 106 S& F Heavy Duty Virtified Tiles 300X300mmx10mm In Flooring All As Specified And As Directed. 107 S& F Heavy Duty Virtified Tiles 300X300mmx10mm In Skirting / Dado As Specified And As Directed. 108 M & L Non-Skid Coloured Ceramic Floor Tiles 7 To 8Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Surface. 109 M&Lbrick Work With Fly Ash Bricks, Straight Or Curved On Plan Exc 6 Mtr Mean Radius Built In Cm 1:6 With Old Size Bricks 110 M&Lbrick Work With Fly Ash Bricks, Straight Or Curved On Plan Exc 6 Mtr Mean Radius In Half Brick Thick Walls Built In Cm 1:6 With Old Size Bricks 111 M & Lrendering In Cm 1:6, 10Mm Thick On Fair Faces Brick Or Concrete Surfaces Finished Even And Smooth Without Using Extra Cement 112 M & L Prepation Of Newly Plastered Wall Surfaces, Apply 3Mm Thick Wall Care Putty And Applyingtwo Coats Of Distemper Oil Emulsion Over A Coat Of Primerall As Specified And As Directed By Engr-In-Charge. 113 M&L For Preparation Of Old Surface And Applying One Coat Of White Wash On Ceiling Surface All As Specified And Directed . 114 S&F Sinks With Drainage Board Made Of Stainless Steel 1Mm Thick Kitchen With Plugs, Washers And Wastes, Including Bedding In Cement Mortar On To Dwarf Wall Or Including Fixing Cantilever Brackets And Connection Union To Pipe, Overall Size 915X460mm Bowl Size 410Mmx330mmx160mm Complete All As Specified And Directed. 115 Hacking Out Old Broken Glass ( Any Thickness, Size, Quality Or Description ) From Wooden Frames Of Stone, Concrete Or Brick Surrounds, Glazed With Putty Or Fixed With Beads. 116 S&F Sheet Glass, Ordinary Quality 4Mm Thick And Glazing With Oil Putty Or Fixed With Beads In Square N.Exc 0.5 Sqm In Each Pane. 117 Taking Down Shutters Of Any Description N. Exc 1.00 Sqm Each All As Specified And Directed. 118 Taking Down Chokhats Or Frames With Shutters ( Without Taking Off The Shutters From The Frames ) Size Exc 1.50 Sqm But N Exc 4 Sqm All As Specified And Directed. 119 S & F For Second Class Hard Wood With Plain, Solid, Straight Chowkats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue Pinned At Joints 120 Supply Only4mm Sheet Glass, Ordinary Quality , N Exc 0.5 Sqm In Each Glass All As Specified And Directed. 121 S & F Butt Hinges Medium Weight Cold Rolled Mild Steel, And Fixed 75 Mm Size 122 S&F 100Mm Long Extruded Aluminium Alloy Handles, Fabricated Type, Anodised And All Asspecified And Directed 123 S&F 200Mm Longaluminium Anodised Barrel Towers Bolts Of Extruded Section And All Asspecified And Directed 124 Removing Buildingmaterialout Side The Campus Including Loading And Unloading Etc., To A Distance Exc 5.0 Km But Not Exc 10.0Km Out Side The Md Land ( Ministry Of Defence ) Where Responsibility Regarding Place Of Deposition And Obtaining Permission From All Authorities Etc., In This Regard Will Be Of Contractor Responsibility And Allas Specified. 125 S & F Pvc ( Swr ) Pipe 75Mm Diasingle Sockted In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And Directed. 126 S & F Pvc ( Swr ) Pipe 110Mm Diasingle Sockted In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And Directed. 127 S&F 20Mm Bore Gun-Metal , Globe Or Gate Valve, With Iron Wheel Head, Screwed Both Ends For Iron Pipe Fixed Complete All As Specified And Directed. 128 S&F Soap Dish ( Poly Carbonate ) Complete All As Per Specified And As Directed By Engineer-In-Charge. 129 S&F In Repairs 125Mm Dia Shower Rose Brass Chromium Plated With Or Without Seivel Joints, Including Fixing To Steel Pipe Or Union Complete All As Specified And Directed. 130 S & F Factory Made Solid Panel Pvc Door Shutter 30Mm Thick ( Style ) Consisting Of Frame Made Out Of M.S Tube For Top & Bottom Rails. M.S Frame Shall Be Covered With Heat Moulded Plain Colour Pvc C Channel Having Pvc Sheet Strip Of 20Mm Width Stuck In Side With Solvent Cement For Stiles And Plain Colour Pvc Sheet For Top Rial, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail, Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement , Suppling & Fixing In The Frame At Site As Per Specification & Drawing Etc Complete All As Specified And As Directed By Engineer-In-Charge. 131 M & L For Cement Concrete Type C1, 1:3:6 ( 20Mm Graded Stone Aggregate ) 75 Mm Thick As In Plinth Protection Including Necessary Form Work As Required. 132 M & L For Providing And Injecting Chemical Emulsion For Post Constructional Antitermite Treatment Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion At The Rate Of 7.5 Litres Per Sq.M Of The Vertical Surface Of The Sub-Structure To A Depth Of 300Mmincluding Excavating Channel Along The Wall And Rodding Etc. Complete All As Specified And As Directed By Engr-In-Charge. 133 Dismantling Of Asbestos Cement ( Corrugated, Semicorrugated, Etc. ) Sheets In Roof Coverings 134 S & F Pre - Painted Galvalume Aluminium Zink Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of Any Color Having Tensile Stregth Of 550 Mpa As In Roof Covering / Cladding Fixed To Walls Fixed With Self Tapping Screws As Specified. 135 M&L For Pcc 1:2:4 Type B0 In Roof Slabs ( Average Thickness 50Mm ) Using Water Proofing Compound Complete All As Specified And Directed By E-I-C. Note : Wpc Shall Be Measured And Paid Separately 136 M & L Precast Cement Concrete 1:2:4 Type B1 Using 20 Mm Graded Stone Aggregate As In Cover Slab Of Manhole, Drain Cover, Chullah, Water Troughs Water Troughs, Shelves Etc Similar Work With Plain Faces And Set In Cm 1:4 Complete All As Specified And Directed. 137 S & F Rolled Mild Steel Work In Tubular Trusses Including Special Shaped Washer Etc.Complete Using Erw Or Induction Butt Welded Tubes Conforming To Is 1161-1979 Grade St-240. 138 S & F Roof Trusses ( Framed ) , Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing ( Beam, Tee, Angle, Channel Or Flat Sections ) Including Distance Pieces, Cleats Etc To Fe 410-W ( Gde-E-250 ) Quality -A 139 Dismantling Ceiling Boards Any Description Any Thickness Including Cover Fillets All As Specified And Directed 140 S&F Anodised Aluminium Snap Grid Frame Work For False Ceiling All As Specified 141 S&F Exposed Metal Frame Ceiling With Calcium Silicate Board Of Siliceous And Calcareous Material Reinforced With Cellulose Fibre For Fixing In 600 Mm X 600Mm Grid ( Frame Work For Ceiling Shall Be Measured And Paid Separately ) . 142 S&F Hangers 6 Mm Dia. G.I. ( Upto 1200Mm Length ) Adjusting Level Fixed To Roof Slabs By Means Of Ceilling Cleats Made Out Of G.I. Flat 40 X 3 Mm Size 60Mm Long And Expansion Hold Fasteners 12.5Mm Dia. 40Mm Long Complete All As Specified 143 M & L For Granite ( Of Any Type ) Tiles 20Mm Thick Machine Cut, Bedded And Jointed With Gray Cement Slurry And Pointed With White Cement Withadmixture Of Pigment To Match The Shade Of Granite Stone Including 15Mm Thick Screed Bed Or Bedding Layer Of In Cm 1:6All As Specified And As Directed. 144 M & L For 18 Mm Thick Veneered Decorative Plywood, Grade 1 ( With Bwr Resin ) With Decorative Face Veneers On Both Faces; Fixed With Screws To Timber Frame Work Etc Complete All As Specified And As Diirected. 145 S&F Continous ( Piano ) Hinges 30Mmwidth Mild Steel, Bright Finish Or Electrogalvanised Complete All As Specified And Directed. 146 S&F 100 Mm Long Hasp And Staple, Aluminium Anodised, Inclufing Bolt To Hinge Plate And Fixed With Screw Complete All As Specified And Directed. 147 M&L Hardcore With Broken Stone Or Boulders Of Gauge Not Exc 63 Mm Deposited Spread And Leveled In Layers Not Exc 15 Cm Thick Watered And Rammed To A True Surface . 148 M&L For Chequered Cement Concrete Tiles 30Cm X30cm X 25Mm Thick, Set, Jointed And Pointed In Neat Cement Slurry With Grey Cement And Pigmentin Floors Including 20 Mm Thick Screed Bed Or Beding Layer In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 149 M&L Pcc 75 Mm Thick , Type D21:4:840 Mm Graded Aggregate As In Sub Base 150 Supply And Fixing Factory Made Upvc White Colour Three Track Three Panels Sliding Window With Fly Proof Ss Wire Mesh ( Two Nos Glazed & One No. Wire Mesh Panels ) Upto 1.50M Height Made Of ( Big Series ) Frame 116X45mm & Sash 46X62mm Both Having Wall Thickness Of 2.3+ 0.2Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. ( Area Of Window Above 1.75 Sqm ) Comprising Of Upvc Multi Chamfered Frame, With Inbuilt Roller Track And Sash Extruded Profiles Duly Reiforced With 1.60+0.2Mm Thick Galvanised Mild Steel Section Made From Roll Forming Process Of Required Length ( Shape And Size According To Upvc Profile ) , Appropriate Dimension Of Upvc Extruded Glazing Beads And Upvc Exruded Interlocks, Epdm Gasket, Wool Pile, Zinc Alloy ( White Powder Coated ) Touch Locks With Hook, Zinc Alloy Body With Single Nylon Rollers ( Weight Bearing Capacity To Be 40Kg ) , Gi Fastners 100 X 8Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fuson Welded At All Corners, Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. After Fixing Frame , The Gap Between Frameand Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Approved Quality , Complete All As Specified And Directed By Engineer-In-Charge. ( Glass Or Wire Mesh Shall Be Paid Separately ) 151 Spply And Fixing Factory Made Upvc White Colour Fixed Glazed Window / Ventilator Made Of ( Small Series ) Frame 47X50mmmullion 47X68mm Both Having Wall Tickness Of 1.9+ 0.2Mm And Single Glazing Bead Of Appropriate Dimension. ( Area Upto 0.75 Sqm ) Comprising Of Upvc Multi Chamfered Frame, And Mullion ( Where Ever Required ) Extruded Profiles Duly Reiforced With 1.60+0.2Mm Thick Galvanised Mild Steel Section Made From Roll Forming Process Of Required Length ( Shape And Size According To Upvc Profile ) , Upvc Extruded Beads Of Appropriate Dimension Of Epdm Gasket, Gi Fastners 100 X 8Mm Size For Fixing Frame To Finished Wall, Plasyic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame Shall Be Mitred Cut And Fuson Welded At All Corners, Mulion ( If Required ) Shall Be Also Fusion Welded Including Drilling Of Holes For Fixing Of Hardwares And Drainage Of Water Etc. After Fixing Frame , The Gap Between Frameand Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Approved Quality , Complete All As Per Approved Drawing & Direction Of Engineer-In-Charge. ( Glass Or Wire Mesh Shall Be Paid Separately ) 152 Taking Down Old Unserviceable Point Wiring ( Light, Fan Socket Or Power ) Complete, Including Fixture And Fittings Such As Switches, Ceiling Rose, Pendents, Regulators, Sockets, Light Fittings Etc.Removing Materials For Keeping For Taking Credit ( Credit For Above Items Should Be Made As Per Conditions Separately ) And Making Good Disturbed Surface Of Walls Floors Etc. All As Specified. 153 Taking Down Old Unserviceable Submain Wiring Of Any Size Including Gi / Copper Earth Continuity Conductor In Pvc Conduit On Wall / Roof And Making Good To Disturbed Surfaces All As Directed. 154 Taking Down Ceiling Fan, Sealing Cable End, Dismantling Blades From Fan And Keeping In Safe Custodyfor Reuse At Site Andmaking Good Disturbed Surfaces Complete All As Specified And As Directed. 155 Refixingonly Ceiling Fan With And Including Carrying Out Cleaning Servicing, Oiling And Greasing Of Ceiling Fans And Connecting Up Including Provision Of Cable From Celling Rose / Connector To Fan All As Specified And As Directed. 156 M& L Painting Of Ceiling Fan Complete, In Situ With Synthetic Enamal Paint By Spraying Incl Filling Cavities With Filler, One Coat After Cleaning All Dust Etc All As Specified And As Directed. 157 Disconnecting Electric Connection And Taking Down Main Switch / Db Of Any Size And Keep In Safe Custody For Taking Credit Complete And Good / Levelling The Disturbed Surfaces Of Wall To Match With Existing Surface. 158 M&L For Concealed Point Wiring Complete With 1.5 Sqmm Single Core Pvc Insulted Frls Cable 1100 Volts Grade Multistrandedcopper Conductor Drawn Through In And Including 20Mm Dia Pvc Rigid Non Metallic Conduit Concealed With All Accessories Such As Internal Bend, End Caps Etc Complete Concealed In Walls And Surface In Ceiling / Roof / Etc Including 1.5 Sqmm Single Core Pvc Insulated Frls Cable 1100 Volts Grade With Multistranded Copper Conductor Cable As Earth Continuity Conductor Including Fabricated Branded Modular Metal Flush Box Concealed In Walls With Suitable Modular Plate With Cover With Suitable Screws For Housing Switches, Socket Outlets, Fan Regulators Etc All As Specified And As Directed For The Following :- ( A ) One Light Point Controlled By One, One Way Switch. 159 ( B ) One Ceiling / Exhaust Fan Point Controlled By One, One Way Switch. 160 ( C ) Oneswitch Socket Outlet Point 5 Amps On Independent Board. 161 ( D ) One05 Amps Socket Outlet Pointon Same Board. 162 All As Per Item No.158 Described Here-In-Before But With Copper Conductor Cable Frls, 4.00 Sqmm For One 3 Pin Socket Outlet, 15 Amps And Including 4 Sqmm Pvc Insulated Copper Conductor Cable As Earth Continuity Conductor On Independent Board. 163 Note For Item No. 158 &159 : Cutting Chases And Making Good In Wall / Floor Will Be Measured And Paid Seperately. 164 Supply And Fixing Led Lights Fitting 1X 20W, 220V, Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete.Make-Havells / Bajaj / Crompton 165 Supply And Fixing Led Light Fitting Mirror Type Withhigh Out Put Diffuser 2 Feet, 10 Watt 220 V Acdecorative Type With Driver Holder And Led Lampincluding Connecting Up With Three Core Flexiblecopper Conductor Cable Of Suitable Size Complete.Make-Havells / Bajaj / Crompton 166 S & F Led Light Fitting 1X9w / 1X10wbulkheadluminaires Including Led Light Driver Holderconnecting Up With Three Core Flexible Copperconductor Cable Of Suitable Size.Make-Havells / Bajaj / Crompton 167 Supply And Fix Mcb Db, Spn, 8 Ways, Isolated Neutral Bar With Single Doorip54 Protection, Door Earthing Arrangement With Cement Spill Protector, Mechanical Impact Strength Ik09 Complete. Make: L&T / Legrand / Havells 168 Supply And Fix Mcb Spn 32 Amps, 240Volts, 10 Ka, B Curve Complete. Make: L&T / Legrand / Havells 169 Supply And Fix Mcb Sp 6 To 32 Amps, 240Volts, 10 Ka, B Curve Complete. Make: L&T / Legrand / Havells 170 Supply And Fix Ceiling Rose Surface Type Bakelite 65 X 50Mm With Three Terminals. 171 S&F Modular Fan Regulator Step Type 120 W, 2 Module Complete All As Specified And As Directed. 172 S&F Switch Modular 6A Single Pole, One Way, 1 Module Complete All As Specified And As Directed. 173 S&F Switch Modular 16A Single Pole, One Way, 1 Module Complete All As Specified And As Directed. 174 S&F Socket, 6A - 2 / 3 Pin Combined 2 Module Complete All As Specified And As Directed. 175 S&F Socket 6A / 16A - 2 / 3 Pin Combined 2 Module Complete All As Specified And As Directed. 176 M&L For Concealed Sub Main Wiring By Making Recess In Wall / Surface Complete With 2 Runs Of 6 Sqmm Single Core Pvc Insulated Frls Cable 1100 Volts Grade Multistranded Copper Conductor Cable With 1 Run Of 6 Sqmm Single Core Pvc Insulated Frls Cable 1100 Volts Grade, Multistranded Copper Conductor Cable As Earth Continuity Conductor, Drawn Through And Including 25 Mm Or Higher Dia Non Metallic Rigid Pvc Conduit And Conduit Accessories Suface / Concealed In Wall / Ceiling Etcfor Three Phase Sockets All As Specified And As Directed By Engr - In- Charge. Note :- 2 Runs Of 6 Sqmm, + 1 Run Of 6 Sqmm ( Earth Cotinuity Conductor ) And 1 Run Of Pvc Conduit Shall Be Measured As One Unit Length. 177 M & L Earthing Complete With Galvanised Steel Earth Plate Electrode 60Cmx60cmx6mm Thick Burried Directly In Ground Vertically To A Depth Not Less Than 2.25 Metre Below Ground Level With Top Edge Of The Earth Plate At A Depth Not Less Than 1.5 M Below Ground Level, Earth Plate Surrounded By 15Cm Thick And Packed With Layers Of Charcoal Dust And Common Salt , Earth Lead Gi Wire 4Mm Dia ( 8 Swg ) Connectd To Gi Earth Plate Elcectrode By Means Of Bolts, Nuts, Check Nuts, Washers Of Galvanised Iron, Thimbles And Other End Of Earth Wire Connected To Main Switch Board / Feedar Pillar And Protected By Galvanised Iron Pipe Medium Grade 15Mm Bore And20mm Bore Medium Grade Gi Pipewith Funnel And Wire Mesh For Watering Including Necessaryexcavation And Earth Works. Pcc Chamber In Cement Concrete 1:2:4 Type B-1 & Rcc Cover And All As Shown In Electrical Plate No. 3 Of Ssr ( Part-I ) Of 2009. ( I ) The Unit Rate Includes Earthing Wire, And Protection Pipe Upto 7.5 Metre. 178 Cutting Chases, Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; Andcutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Not Exc 10 Cm Girth 179 M& L For Making Opening For Fixing Of Exhaust Fan Of Size 300 Mm Sweep Complete And Making Good The Disturbed Surface Complete. 180 Supply And Fix Exhaust Fan, Steel Bodyac Single Phase. 230V Of Size 300Msweep With, Blades, And Frame Andlouvers 181 Supply And Fixing Wall Mounted Fan 400 Mm Sweep, High Speed, Single Phase, 230 Volts , 50 Hz Complete. Make-Havells / Crompton / Bajaj.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 44.99 Lakhs /-

BOQ Items

NAME OF WORK:SPECIAL REPAIRS TO CERTAIN BLDGS AND COMMUNITYHALL (P-75) AT AFAC COIMBATORE
Sl. No. Item Description
1Removal of Plants/ Shrubs grown on walls/ slabs/beams by making holes or demolition of concrete etc and including applying suitable chemical for killing the roots of Plants, filling of holes with concreteand making good complete all as specified and directed.
2Chipping/removing loose concrete in cloumns/beams/ chajjas/roof slab etc. up to reinforcement bars without damaging the reinforcement, removing all the loose material and to make all the exposedsurface free from dust and all impurities etc complete allspecified and directed.
3Removing corrosion of steel reinforcement by mechanical means like wire brushing, chipping to remove loose rust and then applying rust removal solution Reebaklens RR of Fosroc / Sika Rust off 100 / equivalent in bostic India Ltd by using brush application, leaving the surface for at least 15 to 30 minutes, then removing loose materials by scrubbing or with brush and applying anti corrosive coating to reinforcement Nitozinc primer of Fosroc/Sika Friazinc R / equivalent in Bostic india Ltd , all as recommended by product manufacturer.
4Providing and applying one coat of structural grade epoxy coat by brush of approved make . Mixing of two components will be as directed by manufacturer .Application shall be provided not more than 5 hours before application of micro concrete/polymer mortar etc complete all as specified by the manufacturer.Make:- Nitobond EP of FOSROCK/ Sikdur 32LP/ equivalent in Bostic India Ltd
5Providing and applying n exc 40 mm thick (In layers of each 10mm thick) Shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar Renderoc SP 40 of Fosroc / Sika plastocrete plus/ equivalent in bostic India ltd, mixed with water in a water & powder ratio 0.18 in ceiling of roof slab/Chajjas/Beams/Parapet walls etc. Note:- Quoted tate is deemed to be inclusive of provideing scaffolding for working in patches upto a height of 15 Mtr complete all as specified and directed.
6Surface grinding, Rounding off all edges to minimum of 25mm radius andand applying Nitowrap CWS 230 of fosrock (or) sika wrap 230C, uni directional, high strength, light weight, non corrosive carbon fiber sheets of all around the periphery of pier for entitre height of pier.The FRP fabric used shall be ofzero degree unidirectional fibers havingfiber density of 1.8 g/cc and shall have tensile strength > 4900 MPa ; tensile modulous > 230 GPa and ultimate elongation of 2.1%. The substrate shall be primed with Nitowrap 30 epoxy primer &Nitowrap 410 impregnating resin saturant shall be used for saturating the fibers.Saturant used shall have tensile strength of >30 MPa; Elongation > 2% ; Flexural strength > 30 MPa ; Tensile Modulous > 2400 MPa & Flexural Modulous > 1700 MPa when tested as per ASTM D638 Type I and ASTM D 790 & Glass Transition Temperature > 50 deg Celcius as per ASTM E 1356. The adhesion of the entire system (FRP Sheet, Saturant and primer combined) with concrete shall be > 3.5 MPa with concrete failure as per ASTM D 4541.Wrapping the CFRP fabric to RCC member atdesired orientation using tamping rollers to avoid any airvoids etc. and sprinkling sand over it as per direction and satisfaction of Engineer-in-charge, etc, complete. Product used shall have CE (CE-29842) marking and compliance according to Construction Products Directive 89/106/EEC (CPD)
7Demolition of RCC Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work .
8M&L for flat form work for rough finished surfaces to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
9M&L for flat form work for rough finished surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) .
10M&L for RCC M-25 in beams, cantilevers, bressummers, lintels over 1.5m span
11M&L for RCC M-25 in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
12S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
13All as above item but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
14Taking down existing roof treatment includingscreed bed , APP membrane etc upto mother slab of roof and cleaning with wire brushe and water complete , including shifting of mulba from roof to ground floor for futher disposal all as specified and directed by E-I-C.
15M&L for PCC 1:1.5:3 type B0 admixed with Nitobond SBR of Fosrock (or) equivalent products in Sika/Asain paints @ 2% by weight of cement in roof slabs for filling up spots of loose screed/concrete , complete all as specified and directed by E-I-C.
16Supply and application of single component, seamless, spray applied, hybrid elastomeric PU based material i.e Nitoproof 725 of Fosroc chemicals (or) sikalastic 590 of Sika India Pvt Ltd (or) equivalent in any approved make as approved by GE over a coat of primer i.e Nitoproof WB primer of Fosroc chemicals (or) diluted sikalastic 590 of Sika India Pvt Ltd (or) equivalent in any approved make as approved by GE, all as recommended by manufacturer ans as specified. Note:-(i) Average minimum DFTof PU based material shall be 1mm and shall be applied by using a Graco pump. (ii) PU based material shall process the following properties solids by volume -65%, tensile strength ASTM D412-1.75Mpa, density 1.3 g/ml, elongation ASTM D-412-350%, Adhesion to substrate concrete-1.9Mpa, resistance to water-10m pressure. (iii) Rate are deemed to be include for cleaning and preparation of surface to receive PU water proofing system including filling of cracks with cementitious repair mortars i.e renderoc CS of Fosrock chemicals (or) equivalent of approved make. (iii) Work shall be got carried out by authorised applicator of the manufacturer and it shall be got approved by the GE before progressing the work. (iv) 10 years of guarantee shall be provided and security amount shall be deposited as speicified in tender documents.
17Taking down cement plaster on brick or stone walls, ceilings, etc including racking out Joints, hacking for key, scrubbing down with water, etc
18M & LRendering in CM 1:3, 5mm thick on fair faces of brick work or concrete surfaces on ceiling complete all as specified.
19M & L for preparation of newlyplastered surfaces and applying threecoats of white washon ceiling.surface all as specified.
20M&L for Rendering with WPC in CM 1:4, 15mm thick on othe thanfair faces of brick work or concrete surfaces all as specified and directed. Note : WPC shall be measured and paid separately
21M&L for Rendering in CM 1:6, 10mm thick on fair faces of brick work or concrete surfaces all as specified and directed.
22M & L preparation newly plasteredof wall surfaces and applyingtwo coats of cement base paint over a coat of primerall as specified and as directed directed by Engr-in-charge.
23M & L prepation of newly plastered wall surfaces and applyingtwo coats of distemper oil emulsion over over a coat of primerall as specified and as directed directed by Engr-in-charge.
24Supply only Intergral waterproofing compound
25Preparation of old treatedof wall surfaces and applyingone coat of cement base paintall as specified and as directed directed by Engr-in-charge. Note:- (i) This item of work shall be executed upto a height of 30 Mtr height buildings/Structures/RCC OHTs. (ii) Scaffolding required to be done for executing the work above the normal heights as specified in SSR Pt-II shall be measured and paid separately under a separate item for the whole building/structure.
26M & L for applyingone coats of distemper oil emulsion on old treated/decorated surfaces of wall including preparation of wall all as specified and as directed directed by Engr-in-charge.
27M & L for preparation of oldplastered surfaces and applying twocoats of white washon ceiling.surface all as specified.
28M & L for preparation of oldtreated wall surfaces and applying twocoats of white washall as specified.
29Preparing old surface of wood and wood based material of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint.
30Preparing old surface of steel and steel based material of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint.
31Providing & fixing double steel scaffolding system (cup lock type) on the exterior side of the building/structure, including additional rows of scaffolding in stepped manner as per requirement at site, made with 40mm dia MS tube, placed 1.5mtr c/c(Maximum), horizantal & vertical MS tubes jointed with cup & lock system in the scaffolding for working platform etc amd maintaining it in a serviceable condition for execution of work and removing it thereafter. the scaffolding system shall be stiffned with bracings, runners, connecting with building etc wherever required to ensure safety of workmen all as directed by Engr-in-charge. Note:- 1.Area derived by multiplying the outer most external perimeter and height of the building /structure shall be measured for payment. 2. The payment shall be made only once after completion of all external items of work w.r.t the building/structure. 3. After completion of the work the material of the scaffolding shall be the property of the contractor and required to be removed from the site.
32Demolition of concrete in above ground floors and pavings exc 15 cm thick
33Dismantling floor, hearth or wall tiling including cement mortor bedding (but not backing to stone and rubbish off the premises complete all as specified and directed.
34M & L for Non-skid coloured ceramic tiles 7 to 8mm thick(square / rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface all as specified and as directed by Engr-in-charge..
35M & L for Non-skid coloured ceramic tiles 7 to 8mm thick(square / rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface all as specified and as directed by Engr-in-charge..
36M & L Glazed coloured ceramic tilesin vertical surface 350x250x7mm/450x350x7mm thickset and jointed in neat cement slurry and pointed in white or coloured cement to match the surface all as specified and as directed by Engr-in-charge..
37M&Lfor Screed bed or bedding layer of mortor 15 mmthick in CM 1:6 for laying floor finishes all as specified and directed.
38M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4as in backing coat of skirting /dado all as specified and directed.
39M&L for brick work with sub class "B" bricks, old size, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 complete all as specified and directed.
40Demolition of Brickwork or stone/ boulder masonry, built incement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
41Taking down chowkhats or frames with shutter (with out taking off the shutters from the frames) size not exc 1.50 sqm each and all as specified and directed.
42Taking down shutters of any descriptionexc 1 sqm and n exc 2sqm each all as specified and directed.
43S&F IInd class hard wood , 35mm thickplain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers all as specified and directed.
44S&F IInd class hard wood, 35 mm thick Glazed and skeletonshutter, open rebated and prepared to receive glass , gauge, etc without sash bars but divided into squares, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.24 (a) and fitted to chowkatscomplete all as specified and as directed by Engineer-in-Charge.
45S & F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, suplying and fixing in opening as per specification and drawing etc complete all as specified and as directed by Engineer- in-Charge.
46S & F Factory made solid PVC Moulded door shutter with wood EPS, 30mm thick , with 2,4, or 6 raised panel design with 2mm thick mouldedprelaminated PVC Sheet on both facessupplying & fixing in the frame at site as per specification & drawing etc complete all as specified and as directed by Engineer-in-Charge.
47Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded .
48Ditto, but without glazing bars
49S&F mild steel work in hold fasts etc and similar work conforming to Fe-290 Gde E-165.
50Preparing surfaces of wood and wood based materials, steel and iron work , new or old , treating small articles such as stop, covers gully gratings, hold fasts ends of posts, back of chowkats etc , area n exc 0.1 Sqm each and treated with tar or coal tar black paint.
51M&L for cement concrete type B1 1:2:4 (20mm graded aggregate) for fixing of hold fast, including finished to match with exiting surfacesall as specified and directed.
52S&F IInd class hard wood,small fittings such as shaped door and window stops and like articles n exc 200 Cu cm each all as specified and directed.
53S&F300mm long Aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing bolts and sliding bolts of extruded sections or cast aluminum alloycomplete and all asspecified and directed
54S & F Floor door stopper 140mmlong with cover plate of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor
55S&F100mm long butt hinges, medium weight, coldrolled mild steel and all asspecified and directed
56S&F 150mmaluminium alloy , anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy all as specified and as directed.
57S&F 150mm longAluminium anodised barrel towers bolts of extruded section and all asspecified and directed
58S&F 150mm extruded aluminium alloy handles, fabricated type anodised asspecified and directed
59M&L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surfaces all as specified and directed.
60Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
61M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces all as specified and directed.
62Supply only3 mm figured glass, ordinary quality ,n exc 0.5 sqm in each glass all as specified and directed.
63Supply only stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless stell wire staples.
64S&F in repair only4mm sheet glass, ordinary quality ,n exc 0.5 sqm in each glass all as specified and directed.
65S&F in repair3 mm figured glass, ordinary quality ,n exc 0.5 sqm in each glass all as specified and directed.
66S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless stell wire staples.
67Taking up or down steel tubing and connections, and removing to store for taking in account of credit for 15mm bore complete all as specified and directed.
68All as per itemabovebut for 20 mm bore
693-layer PP-R (Polypropylene random copolymer) concealed pipes/un concealed pipes SDR 7.4(PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain and brass threaded poly propylene random fittings fixed complete to walls/ceilings or laid on floors of 16mm outer dia of pipe all as specified and as directed
70All as per item No 69 above but 20mm dia
71Taking down & Refixing PPR 15mm/16mm pipes
72Taking down & Refixing PPR 20mm
73S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white including seat cover and flush pipe etc complete all as per specified and as directed by Engineer-in-Charge.
74S & F in repairs PVC valveless, syphonic action type, flushing cistern of 10 Ltrs capacity , low level , white, with inlet , ball valve, float and handle including brackets and flush pipe etc complete all as specified and as direted by Engineer-in-Charge.
75S& F in repair Vitreous China wash basin, white, flat back, size 450x300mm excluding taps, waste, chain and plug and porcelain stopper but including brackets including 32mm PTMT waste cupling , complete all as specifed and directed.
76S&F in repairs Bib taps, brass chromium plated fancy type with cruch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore.
77S&F in repairs two way Bib taps, brass chromium plated fancy type with cruch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore.
78S&F in repairs Pillar taps fancy type cast copper alloy,with capstain head, chromium plated screwed down high pressure, with long shanks and fly nuts screwed for iron pipe and fixed 15 mm bore.
79S & F PVC connections 15 mm size with PTMT nuts of length 450 mm
80S&F in repairs chromium plated angle valves, cast copper alloy, screwed down high pressure with crutch or butterfly handles screwed both ends for iron pipes or for unions and fixed. 15 mm size.
81S&F brass chromium plated health faucet with hand held and spring operated control valve with PVC flexible pipe connection of suitable length as directed fixed to 15 mm bore pipe.
82M & L 75mm dia for PVC (SWR) multi floor trap ofwith grating including jointing with solvent cement etc complete,
83S & F in repairs 110mm dia PVC (SWR) pipe single sockted in any length with rubber ring joints fixed to wallwith clamp complete all as specified and directed.
84S&F 110mm radius PVC (SWR) bendscomplete all as specified and directed.
85S&F 110mm radius PVC (SWR) branch piece, single (single T) equal or unequal complete all as specified and directed.
86S & F in repairs75mm dia PVC (SWR) pipe single sockted in any length with rubber ring joints fixed to wallwith clamp complete all as specified and directed.
87S & F 50mm diaUnplasticised PVC pipe of pressure rating 10 kgf /cm2 fixed complete to walls, ceiling or in floors etc complete
88M & L for 125/110mm dia PVC (SWR) gullytrap including setting jointing with solvent cement etc complete,
89S&F 110 mm borePVC (SWR) vent cowl
90S&F 600mm x 450mm bevelled edge looking mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed towooden plugs with chromium plated brass screws and cup washers.
91Dismantling of PVC water tank 500 ltr capacity and removing to store
92S&F moulded polyethylene 500 ltr water tank storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engr-in-charge.
93S&F in repairs 25 mm Ball brass valves, high pressure, with polythene float and flynut cimplete screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
94M&L for cement concrete type B1 1:4:8 (20mm graded aggregate) in filling and mass concreteall as specified and directed.
95M&L forsand cushioning under floor or in foundation including watering and consolidation for laying of interlocking pavour block.
96Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigments
97Removalof debris/building material out side the campus including loading and unloading, etc to a distance exc 5Km but n exc 10 km out side the MD land complete all as specified and directed. Note:- Location and permission of depositing the building materials/debris disposal outside the MD land shall rest with contractor at his own arrangement.
98Taking down chain link fencing including MS straining rods and MS flat iron strips all as directed by Engr-in - Charge
99Fixing only chain link fencing including line wires any mesh size and type of standerds rails scraining babs etc incl permission o binding wire(Note Supply of chain link will be measured seperately).
100Supply only chain link MS galvanized fencing of any mesh size and type Note fixing shall be measured under serial item no here in above.
101M& L Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165
102Tie bars with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts conforming to Fe- 290 Gde-E-165
103Dismantling wrought iron or mild steel work of any description not otherwise provided for
104Demolition ofCement concretein below or above ground level and paving not exc 15 cm thickness
105M&L 25 mm thick cement concrete type B-0,1:2:4 (12.5 mm graded aggregate) as in sub base of floors without extra cement all as specified.
106S& F Heavy duty Virtified tiles 300x300mmx10mm in flooring all as specified and as directed.
107S& F Heavy duty Virtified tiles 300x300mmx10mm in skirting/dado as specified and as directed.
108M & L Non-skid coloured ceramic floor tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface.
109M&LBrick work with fly ash bricks, straight or curved on plan exc 6 mtr mean radius built in CM 1:6 with old size bricks
110M&LBrick work with fly ash bricks, straight or curved on plan exc 6 mtr mean radius in half brick thick walls built in CM 1:6 with old size bricks
111M & LRendering in CM 1:6,10mm thick on fair faces brick or concrete surfaces finished even and smooth without using extra cement
112M & L prepation of newly plastered wall surfaces, apply 3mm thick wall care putty and applyingtwo coats of distemper oil emulsion over a coat of primerall as specified and as directed by Engr-in-charge.
113M&L for preparation of old surface and applying one coat of white wash on ceiling surface all as specified and directed .
114S&F sinks with drainage board made of stainless steel 1mm thick kitchen with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connection union to pipe, overall size 915X460mm bowl size 410mmX330mmX160mm complete all as specified and directed.
115Hacking out old broken glass (any thickness, size, quality or description) from wooden frames of stone, concrete or brick surrounds, glazed with putty or fixed with beads.
116S&F Sheet glass, ordinary quality 4mm thick and glazing with oil putty or fixed with beads in square n.exc 0.5 sqm in each pane.
117Taking down shutters of any description n. exc 1.00 sqm each all as specified and directed.
118Taking down chokhats or frames with shutters (without taking off the shutters from the frames) size exc 1.50 sqm but n exc 4 sqm all as specified and directed.
119S & F for Second class hard wood with plain, solid,straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints
120Supply only4mm sheet glass, ordinary quality ,n exc 0.5 sqm in each glass all as specified and directed.
121S & F Butt hinges medium weight cold rolled mild steel, and fixed 75 mm size
122S&F 100mm long Extruded aluminium alloy handles, fabricated type, anodised and all asspecified and directed
123S&F 200mm longAluminium anodised barrel towers bolts of extruded section and all asspecified and directed
124Removing buildingmaterialout side the campus including loading and unloading etc., to a distance exc 5.0 Km but not exc 10.0Km out side the MD land ( Ministry of Defence)where responsibility regarding place of deposition and obtaining permission from all authorities etc., in this regard will be of contractor responsibility and allas specified.
125S & F PVC (SWR) pipe 75mm diasingle sockted in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
126S & F PVC (SWR) pipe 110mm diasingle sockted in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
127S&F 20mm bore Gun-metal , globe or gate valve, with iron wheel head, screwed both ends for iron pipe fixed complete all as specified and directed.
128S&F soap dish (poly carbonate)complete all as per specified and as directed by Engineer-in-Charge.
129S&F in repairs 125mm dia shower rose brass chromium plated with or without seivel joints,including fixing to steel pipe or union complete all as specified and directed.
130S & F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tube for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC "C" channel having PVC sheet strip of 20mm width stuck in side with solvent cement for stiles and plain colour PVC sheet for top rial, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement , suppling & fixing in the frame at site as per specification & drawing etc complete all as specified and as directed by Engineer-in-Charge.
131M & L for Cement concrete type C1, 1:3:6 (20mm graded stone aggregate) 75 mm thick as in Plinth protection including necessary form work as required.
132M & L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mmincluding excavating channel along the wall and rodding etc. complete all as specified and as directed by Engr-in-Charge.
133Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings
134S & F Pre - painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50 mm thick of any color having tensile stregth of 550 Mpa as in roof covering/cladding fixed to walls fixed with self tapping screws as specified.
135M&L for PCC 1:2:4 type B0 in roof slabs (average thickness 50mm) using water proofing compound complete all as specified and directed by E-I-C. Note : WPC shall be measured and paid separately
136M & L Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in cover slab of manhole, drain cover,chullah, water troughs water troughs, shelves etc similar work with plain faces and set in CM 1:4 complete all as specified and directed.
137S & F rolled mild steel work in tubular trusses including special shaped washer etc.complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240.
138S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc to FE 410-W (Gde-E-250) quality -A
139Dismantling ceiling boards any description any thickness including cover fillets all as specified and directed
140S&F Anodised aluminium snap grid frame work for false ceiling all as specified
141S&F Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately).
142S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
143M & L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with gray cement slurry and pointed with white cement withadmixture of pigment to match the shade of granite stone including 15mm thick screed bed or bedding layer of in CM 1:6all as specified and as directed.
144M & L for 18 mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame work etc complete all as specified and as diirected.
145S&F Continous (piano) hinges 30mmwidth mild steel, bright finish or electrogalvanised complete all as specified and directed.
146S&F 100 mm long Hasp and staple, aluminium anodised, inclufing bolt to hinge plate and fixed with screw complete all as specified and directed.
147M&L hardcore with broken stone or boulders of gauge not exc 63 mm deposited spread and leveled in layers not exc 15 cm thick watered and rammed to a true surface .
148M&L for Chequered cement concrete tiles 30cm x30cm x 25mm thick,set, jointed and pointed in neat cement slurry with grey cement and pigmentin floors including 20 mm thick screed bed or beding layer in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
149M&L PCC 75 mm thick ,type D21:4:840 mm graded aggregate as in sub base
150Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof SS wire mesh (Two nos glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116x45mm & sash 46x62mm both having wall thickness of 2.3+ 0.2mm and single glazing bead/double glazing bead of appropriate dimension. ( Area of window above 1.75 sqm) comprising of uPVC multi chamfered frame, with inbuilt roller track and sash extruded profiles duly reiforced with 1.60+0.2mm thick galvanised mild steel section made from roll forming process of required length ( shape and size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC exruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (Weight bearing capacity to be 40kg), GI fastners 100 x 8mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fuson welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame , the gap between frameand adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and approved quality , complete all as specified and directed by Engineer-in-Charge. (Glass or wire mesh shall be paid separately)
151Spply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47x50mmmullion 47x68mm both having wall tickness of 1.9+ 0.2mm and single glazing bead of appropriate dimension. ( Area upto 0.75 sqm) comprising of uPVC multi chamfered frame,and mullion (where ever required) extruded profiles duly reiforced with 1.60+0.2mm thick galvanised mild steel section made from roll forming process of required length ( shape and size according to uPVC profile), uPVC extruded beads of appropriate dimension of EPDM gasket, GI fastners 100 x 8mm size for fixing frame to finished wall, plasyic packers, plastic caps and necessary stainless steel screws etc. profile of frame shall be mitred cut and fuson welded at all corners,mulion (if required) shall be also fusion welded including drilling of holes for fixing of hardwares and drainage of water etc. After fixing frame , the gap between frameand adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and approved quality , complete all as per approved drawing & direction of Engineer-in-Charge. (Glass or wire mesh shall be paid separately)
152Taking down old unserviceable point wiring (light, fan socket or power) complete, including fixture and fittings such as switches,ceiling rose, pendents, regulators,sockets, light fittings etc.removing materials for keeping for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. all as specified.
153Taking down old unserviceable submain wiring of any size including GI/copper earth continuity conductor in PVC conduit on wall/roof and making good to disturbed surfaces all as directed.
154Taking down ceiling fan, sealing cable end, dismantling blades from fan and keeping in safe custodyfor reuse at site andmaking good disturbed surfaces complete all as specified and as directed.
155Refixingonly Ceiling fan with and including carrying out cleaning servicing, oiling and greasing of ceiling fans and connecting up including provision of cable from celling rose/ connector to fan all as specified and as directed.
156M& L painting of Ceiling fan complete, in situ with synthetic enamal paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc all as specified and as directed.
157Disconnecting electric connection and taking down main switch/DB of any size and keep in safe custody for taking credit complete and good/levelling the disturbed surfaces of wall to match with existing surface.
158M&L for concealed Point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistrandedcopper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed for the following :- (a) One light point controlled by one, one way switch.
159(b)One ceiling/exhaust fan point controlled by one, one way switch.
160(c)Oneswitch socket outlet point 5 Amps on independent board.
161(d) One05 Amps socket outlet pointon same board.
162All as per item No.158 described here-in-before but with copper conductor cable FRLS, 4.00 Sqmm for one 3 pin socket outlet, 15 Amps and including 4 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
163Note for item No. 158 &159 : Cutting chases and making good in wall / floor will be Measured and paid seperately.
164Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.Make-Havells/Bajaj/Crompton
165Supply and fixing LED light fitting mirror type withhigh out put diffuser 2 feet, 10 watt 220 V ACdecorative type with driver holder and LED lampincluding connecting up with three core flexiblecopper conductor cable of suitable size complete.Make-Havells/Bajaj/Crompton
166S & F LED light fitting 1x9W/1X10Wbulkheadluminaires including LED light driver holder connecting up with three core flexible copperconductor cable of suitable size.Make-Havells/Bajaj/Crompton
167Supply and fix MCB DB, SPN, 8 ways, Isolated neutral bar with single doorIP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete. Make: L&T/Legrand/ Havells
168Supply and fix MCB SPN 32 Amps, 240Volts, 10 KA, "B" Curve complete. Make: L&T/Legrand/ Havells
169Supply and fix MCB SP 6 to 32 Amps, 240Volts, 10 KA, "B" Curve complete. Make: L&T/Legrand/ Havells
170Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals.
171S&F Modular fan regulator step type 120 W, 2 module complete all as specified and as directed.
172S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed.
173S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed.
174S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed.
175S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed.
176M&L for concealed Sub main wiring by making recess in wall/surface complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etcfor three phase sockets all as specified and as directed by engr - in- charge. Note :- 2 runs of 6 sqmm, + 1 run of 6 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length.
177M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead GI wire 4mm dia ( 8 SWG) connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts, washers of galvanised iron, thimbles and other end of earth wire connected to main switch board/ feedar pillar and protected by galvanised iron pipe medium grade 15mm bore and20mm bore medium grade GI pipewith funnel and wire mesh for watering including necessaryexcavation and earth works. PCC Chamber in cement concrete 1:2:4 type B-1 & RCC cover and all as shown in Electrical Plate No. 3 of SSR( Part-I) of 2009.(i)The unit rate includes earthing wire, and protection pipe upto 7.5 metre.
178Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth
179M& L for making opening for fixing of Exhaust fan of size 300 mm sweep complete and making good the disturbed surface complete.
180Supply and fix exhaust fan, steel bodyAC single Phase. 230V of size 300msweep with, blades, and frame andlouvers
181Supply and fixing wall mounted fan 400 mm sweep, high speed, single phase, 230 volts , 50 Hz complete. Make-Havells/Crompton/Bajaj.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy