Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-11-2023 | Amendment to BOQ | Other | 02-12-2023 |
| 2 | 28-11-2023 | Amendment to date | Date | 02-12-2023 |
| 3 | 21-11-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-11-2023 |
| Sl. No. | Item Description |
| 1 | SCHEDULE \"A\" PART-I [ B/R WORKS] |
| 2 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for(reinforcement cut as requried to facilitate) complete all as specified and directed |
| 3 | Demolition of Brickwork built in cement motar, stone/boulder masonry, build in lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 4 | M & Lfor Brickwork with flyash old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified anddirected. |
| 5 | Ditto as in item No. 4 but for half brick thick walls built in CM (1:4) complete all as specified anddirected. |
| 6 | Taking down cement Plaster , any description, on brick walls or stone walls and ceiling etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 7 | M & L for15mm thick Rendering in two coats of on fair faces of brick work or concrete surfaces in CM (1:4) using with WPC @ 3% by wt of cement on second coat complete all as specified and directed. ( Note : WPC shall be measured and paid separately) |
| 8 | Supply only Integral water proofing compoundcomplete all as specified. |
| 9 | M & Lfor rendering 15 mm thick on fair faces of brick work or concrete surfaes in CM (1:6) and finised even and smooth (withoutusing extra cement) complete all as specified and directed |
| 10 | M & Lfor 10 mm thick rendering in CM (1:3)on ceiling on soffits and finised even and smooth (withoutusing extra cement) complete all as specified and directed |
| 11 | M & Lfor preparation of newly plastered / concrete surfaces by vacuum based sanding machine and applying two coats of oil bound distemper over a coat of primer over 2 coat ofbirla wall care putty using mechanical tool/auto rollerSmart painting work carried as per PS clause complete all as specified and directed. Note: All work shall be carried out by approved applicator of paint manufacturer only. The same shall be approved before carrying out the work from AGE(I). Contractor should submit Auth applicator certificate before execution of work. |
| 12 | M & Lfor applying 2 coats of water proofing dampshield 2K or home shield damp stop on affected dampness areas using mechanical tool/auto roller and work carried out through manufacturer complete all as specified and directed.Note: All work shall be carried out by approved applicator of paint manufacturer only. The same shall be approved before carrying out the work from AGE(I). Contractor should submit Auth applicator certificate before execution of work. |
| 13 | M & Lfor complete removal of existing surfaces including washing / rubbing down with water of wall by vacuum based sanding machine and applying two coats of oil bound distemper/emulsion over coat of alkali resistant primer including chalk whiting over 2 coatof birla wall care putty using mechanical tool/auto rollerand including necessary scaffoldings as reqd etc Smart painting work carried as per PS clause . complete all as specified and directed . Note: All work shall be carried out by approved applicator of paint manufacturer only. The same shall be approved before carrying out the work from AGE(I). Contractor should submit Auth applicator certificate before execution of work. |
| 14 | M & Lfor Preparation new plastered surfaces plastered and applying three coat of white wash on ceiling complete all as specified and directed. |
| 15 | M & Lfor Preparation Old decorated surfaces and applying two coat of white wash on ceiling complete all as specified and directed. |
| 16 | Taking down chowkhats with shutters (without taking off shutters from the frame) n.exc 1.5 sqm each complete all as specified and directed. |
| 17 | Taking down chowkhats with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4.0 sqm each complete all as specified and directed. |
| 18 | Taking down and refixing the same opening of door Shutters of any descriptionexc 1 sqm but not exc 2 Sqm each and including easing and adjusting before fixing of door shutter complete all as specified and directed. |
| 19 | S & F Aluminium powder coated frame with shutter doors ,Three/ Two track windows and ventilators including joining cleat for fixing EPDM rubber/ neoprene gasket requiredwith extruded built up standardsections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom etc. complete all as specified and directed.Note : Thickness of powder coating not less than 50 micron. Rate including but rubber beading/neoprene gasket, screws, three/ two track rollers, locking arrangements for windows will not be weighted. |
| 20 | S & F for Powder Coated aluminium grill(anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirementcomplete all as specified and directed. Note :Thickness of powder coating not less than 50 micron. |
| 21 | S & F for5.5mm thick, ordinary quality sheet glass ground or obscured or frosted, on one side and glazing with Aluminium clip in square exceeding 0.5sqm in each complete all as specified and as directed |
| 22 | S & F forSS wire cloth 0.45mm nomonal dia of wire and 1.40mm average width of aperture and fixed with SS wire staples complete all as specified and directed. |
| 23 | S & F for plain sheet glass,4mm thick, ordinary quality and glazing with Aluminium clip in square not exceeding 0.5sqm in each complete all as specified and as directed |
| 24 | S & F for 4 mm thick sheet glass Figured glass, pin head type and glazing with glazing clips in squares n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 25 | S & F for125 mm size, Butt hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, type B-11 complete all as specified and directed |
| 26 | S & F for 150 mm long CP decorative type Brass handles, cast type, polished bright handlesfixed to plywood or framecomplete all as specified and directed |
| 27 | S & F for 200 mm length Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed |
| 28 | S & F 100mm long Mortice lock with four levers (vertical type), Brass body and fixed complete all as specified and directed |
| 29 | S & F Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg aluminum die cast bodycomplete all as specified and directed |
| 30 | S & F in repairs Door closer hydraulically of Aluminium (extruded section body) regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed |
| 31 | Disconnecting existing tanks , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required andincludingCleaning repairing, etc reconnecting and re-fixing in the same position. capacity of tank exc 500 ltrs and not exc 1000 ltrs complete all as specified and directed. |
| 32 | S & F rotational moulded polyethylene water storage tank of 500 ltrs capacity (cylindrical verftical with closed top) including dismantling of existing tank including all fittings i.e tank nipple,of 20mm dia Ball brass valves, high pressure, with polythene float and flynutetc hoisted and fixed in position complete all as specified and directed. |
| 33 | S & F for rotational moulded polyethylene water storage tank of 1000 ltrs capacity (cylindrical verftical with closed top) including dismantling of existing tank including all fittings i.e tank nipple,of 25mm dia Ball brass valves, high pressure, with polythene float and flynutetc hoisted and fixed in position complete all as specified and directed. |
| 34 | Supply and fix for 6mm thick Veneered decorative solid Prelaminated hylum sheet, interior grade, prelaminated both side decorative choice lamination fixedto aluminium door shutteretc complete all as specified and as directed. |
| 35 | M & F fo Preparation of new surfaces of wallby vacuum based sanding machine andapplying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. and over1mm thick exterior birla wall care putty in two layers using mechanical tool/auto rollerSmart painting work carried as per PS clause and including necessary scaffoldings upto G+4etc etc complete all as specified and directed.(The makes of exterior grade acrylic emulsion shall be : Asian Paints \" Apex Ultima\", Nerolac paints \" Excel Anti Peel Emulsion\", ICI Dulux \" Weather Shield Max / Ultra Clean Emulsion\", Berger\"Long Life 7\"Note: All work shall be carried out by approved applicator of paint manufacturer only. The same shall be approved before carrying out the work from AGE(I). Contractor should submit Auth applicator certificate before execution of work. |
| 36 | M & Ffor complete removal of existing treatment on walls including washing down, rubbing downby vacuum based sanding machineandapplying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. and over exterior birla wall care putty in two layersusing mechanical tool/auto roller Smart painting work carried as per PS clause and including necessary scaffoldings upto G+4etc etc complete all as specified and directed.(The makes of exterior grade acrylic emulsion shall be : Asian Paints \" Apex Ultima\", Nerolac paints \" Excel Anti Peel Emulsion\", ICI Dulux \" Weather Shield Max / Ultra Clean Emulsion\", Berger\"Long Life 7\"Note: All work shall be carried out by approved applicator of paint manufacturer only. The same shall be approved before carrying out the work from AGE(I). Contractor should submit Auth applicator certificate before execution of work. |
| 37 | S & Ffor20 mm outer dia 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and composite pressure pipes including all Crimp type internal sealing Planstic metal Composite fittings (such as elbows, tees, reducers, couplers, short pieces, connectors, etc.) and hooks (in case of concealed pipe work)/ clamps (in case of exposed pipe work)etc complete all as specified. having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors upto G+4 including taking down GI pipe of 15mm dia etc complete all as specified. |
| 38 | Ditto as in item No. 37but for25 mm dia ditto and including taking down GI pipe of 20 mm dia complete all as specified and directed. |
| 39 | Ditto as in item No.37 but for32 mm dia ditto and including taking down GI pipe of 25 mm dia complete all as specified and directed. |
| 40 | M&L for Cutting holes in brick walls exc half brick but not exc one brick walls built in cement mortar for inserting holdfasts/ rafters /pipes etc and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required and including necessary scaffoldings upto G+4etc complete all as specified and directed. |
| 41 | S & F 25mm outside dia PPR Gate valves (brass insert) as per requirement of sitefixed to PPR pipescomplete all as specified and directed. |
| 42 | Ditto as in item No. 41but for 32 mmoutside dia complete all as specified and directed. |
| 43 | Dismantling floor hearth or wall tiling including cement mortarbedding and rubbish off the premises complete all as specified and directed. |
| 44 | M & Lfor non- skid mat finish ceramic coloured tiles 7 to 8mm thick (square/Rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6.complete all as specified and directed |
| 45 | M & Lfor glazed ceramic coloured design tiles 450x300mm x 7mm thick invertical surface etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thickbacking coat in CM 1:4 etc complete all as specified and directed. |
| 46 | M & Lfor light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6.complete all as specified and directed |
| 47 | - Ditto -as above item No 46 but as in skirting/ dado including rendering/ backing coat of CM 1:4, 10 mm thick etc complete all as specified and directed. |
| 48 | M & L for digital ceramic wall cladding tiles of size 450mm x300mm / 450mm x150mm of 7-8mm thick or 600mm x148mm x10mm thick of as approved by EIC size and colourin vertical surface etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat in CM 1:4all as per manufacturer instruction and including necessary scaffoldings upto G+4 complete all as specified and as directed |
| 49 | S & F in repair PVC pipe160mm dia single socketed in any length with rubber joints fixed to walls with and including necessary scaffoldings upto G+4etc complete all as specified and directed. |
| 50 | S&FStack clamps out of 50 mm by 5 mm flat iron and 6mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roofcomplete all as specified and directed. |
| 51 | S & F PVC (SWR) bends any radius bore of dia 160mm with access door complete all as specified and directed. |
| 52 | S & F PVC (SWR) bends/ shoes/ roof coupling reducerany radius bore of dia 160mm complete all as specified and directed. |
| 53 | M & F for Removal of plantgrowth by injection with chemical glyphospate solution ( 4 % conceneration ) of 20ml or till refuse by cutting or injection in stem of plants or roots at 30mm deep. The area shall then be sprayed with solution 25ml glyphosphate ( 4% concent) dulited with 1 ltr of water. All roots / plants shall be removed completely and making good with cement concrete/mortar and finished the surfaces matching to existing surfaces of wall / floorwith acrylic paint all as directed by EIC.etc sectional area exc 0.10 Sqm and not exc 0.20 Sqm each complete all as specified and directed. |
| 54 | M & F for Ready Mix Micro concrete of25 to 40 mm thick consistency ofRenderoc S2 or Renderoc RG of FOSROCin consistency a batch of25kg of Renderoc mixed with watern exc 3.50 Ltrs and mixed with 1 kg of polymer acrylic fibersall as per manufacturer\"s instructions andfinished the surfaceseven and smooth with 10mm thick rendering in CM 1:4complete all as specified and directed by Engr-in-Charge including erectingnecessary scaffolding (UP to G+5 Story ) Note:- The following stages (a) to (d) are included of all Materrials and labourwill be carried out through approved applicator of manufacturer only :- |
| 55 | (a) Taking out existing unserviceable plaster loose/unsound weaken cement concrete of any description and in any position from existing surface of RCC roof slab/beam/column/RCC facia /RCC chajja with power driver of pneumatic chisel after cleaning of concrete/plastered particlesand Removing corrosion and all loose scales rust etc from the visible reinforcement and cleaning the steel reinforcement properly. (b)Applying one or more coat of NITO ZINK primer of FOSROC or equivalent ZINK primer of CHEMISTIC/WEBAC on visible reinforcement surface. Several time prior to placing, the concrete substrates should be saturated with clean water |
| 56 | (C) After drying of water to applying bonding agent of modified styrene butadiene emulsion (SBR bonding agent i.eNito bond SBR Latex or Nito bond EP of FOSROC) in proportion 1 (Nito bond SBR latex): 1 (water): 3 (OP cement) by volume with the brushing etc to bind New CM plaster / Polymer Modified plaster / Concrete / Screed concrete with old surface.(d) Providing fiber mesh jali fixed to existing RCC roof slab/beam/column/RCC facia /RCC chajja as per directed by Engr-in- Charge |
| 57 | Demolition of cementConcrete (unreinforced) of any description and in anypositionnot otherwise specifically proided and including removing of PCC Tilesand Existing roof treatment etc complete all as specified and as directed. |
| 58 | M & Lfor PCC Padding/levelling course (1:2:4) type B-0 (12.50 mm graded aggregate) thickness as specified to bring uniform slope in floors/ roof slab with addition of integral waterproofing compound Conplast WL Xtra @ 200ml per bag of cement and polypropylene fibres @ 900 grams per cum of concreteand any cracks the cutting of groove6mm x 15mm to be taken at every 5m x 5m and filled with Polyurethane elastomeric sealant Nitoseal PU 40 and coving at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with Nitobond SBR at dosage of 1.5 Ltrs per 50kg cement as per manufacturer\"sincluding over apply with brushing neat cement slurry with 3.0kg/Sqm after cleaning of existing roof top surface with water etc complete all as specified and directed.Note:(a) All work shall be carried out by approved applicator ofmanufacturer only. (b) Integral waterproofing compound Conplast WL Xtra , polypropylene fibres , Polyurethane elastomeric sealant Nitoseal PU 40 & Nitobond SBR will be measured paid sepatarely. |
| 59 | M & Lfor 10mm thick rendering on roof top surfaces in CM 1:3 with using withintegral waterproofing compound Conplast WL Xtra @ 200ml per bag of cement. Finishing the even and smooth surface etc complete all as specified and directed.Note :-Integral waterproofing compound Conplast WL will be measured paid sepatarely. |
| 60 | Supply only Integral waterproofing compound Conplast WL complete all as specified and directed. |
| 61 | Supply only Polypropylene fibres complete all as specified and directed. |
| 62 | Supply only Polyurethane elastomeric sealant Nitoseal PU 40 complete all as specified and directed. |
| 63 | Supply only admixed with Nitobond SBR complete all as specified and directed. |
| 64 | M & Lfor Providing & applying 100% solids content, 2 component, solvent free, spray applied elastomeric seamless Pure Polyurea Membrane Fosroc Polyurea WPE at a thickness of 1.5mm in two layers at a coverage rate of 1.5 litres / sqm. Spray applied waterproofing shall utilize high-pressure, heated plural component spray proportioning equipment and applied in a cross directional method to the total roof slab and parapet wall height. Note: All work shall be carried out by approved applicator ofmanufacturer only.The same shall be approved before carrying out the work from AGE(I). Contractor should submit Auth applicator certificate before execution of work.The cured membrane shall have the following properties(i) Solids by Volume : 100%, (ii) Volatile organic compounds : 0 g/litre(iii) Viscosity : A ISO = 1000mPasandB AMINE 1200 mpas (iv) Tensile strength ASTM D412 : >19 MPa (v) Tear Resistance ASTM D624C : 90N + 4 N/mm (vi) Elongation ASTM D412 : >300% (vii) Shore D ASTM D2240 : 46(viii) Abrasion (1kg,H22 wheels) ASTM D4060: 36 mg /1000 cycles , Abrasion (1kg,CS17 wheels) DIN EN ISO 5470 : 10 mg /1000 cycles (ix)Service temperature ASTM D4060: -30°C to +100°C |
| 65 | Before applying of Polyurea WPE under mentioned prepartions has to be done.(x) The Surface shall be free from sharp projections & undulation, ridges or troughs, etc.The substrates shall be freed of laitance, loose or friable materials, debris and all contaminants by mechanical means preferably using light grinding. (xi) Supply and application of solvent free epoxy resin primer Nitoprime 31 @ min 0.25 kg/Sqm on horizontal surfaces and on verticals to the total height of the parapet wall.Sprinkle dry sand over the primer coat for better adhesion of Polyurea coating |
| 66 | M & Lfor Providing and applying two coats of Dekguard PU/ Nitoproof UR Top coat @ minimum 100 microns dry film thickness in two coats over the Polyurea waterproofing using rubber squeegee and back rolled with lambswool roller.Note: All work shall be carried out by approved applicator ofmanufacturer only.The same shall be approved before carrying out the work from AGE(I). Contractor should submit Auth applicator certificate before execution of work. |
| 67 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid and bedded and pointed in any mortar. |
| 68 | M & L for 16-18 mm thick machine cut,Granite stone slab (of any type)(table rubbed and polished) in plate forms and like in cement mortar 1:4 bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting andpolishing types and making mould on edges & including cutting of three numbers of grooves etc complete all as specified and directed |
| 69 | Material and Labourfor 15-18mm thick of any shade (table rubbed and polished)laid and jointed in flooring strips, window cills and jambsetc of green Marbleover and including 15mm thickbacking coat in CM 1:6 complete all as specified and directed |
| 70 | Dismantling of plain or corrugated steel sheeting , any gauge and thickness in roof covering including Nainital or similar pattern roof covering, complete all as specified and directed. |
| 71 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 72 | M & Lfor Steel work in tabular/hallow sections of trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and directed. |
| 73 | S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.50mm thick of any colour having tensil strength of 550 Mpa, as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 74 | S & F for 1.25 mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: gear operated type with bevel gear box and crank handle complete all as specified and directed. |
| 75 | M & Lfor Preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of aluminum paint over a coat of aluminium red oxide primer complete all as specified and as directed. |
| 76 | M & Lfor Preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamelpaint over a coat of zink primer complete all as specified and as directed. |
| 77 | M & L for preparation of old painted steel surfaces of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed. |
| 78 | Demolition of cementConcrete (unreinforced) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as specified and as directed. |
| 79 | M & Lfor 75mm thick PCC(1:2:4) type B-1 (20 mm graded aggregate) as in plinth protection and finshing the even and fair with out using extra cement etc and including cuting of construction joints every 2.5 mtr and filled with sealing compound grade B etc complete all as specified and directed. |
| 80 | M & Lfor Chequered cement concrete/ parking tiles with glossey finished20cm x 20cm x 25mm / 30cmx 30cmx 8 to 10 mm thick,set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6.complete all as specified and directed |
| 81 | S & Fin repair PVC pipe110mm dia single socketed in any length with rubber joints fixed to walls with Stack clamps out of 50 mm by 5 mm flat iron and 6mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roofcomplete all as specified and directed. |
| 82 | S & Fin repair PVC pipe75mm dia single socketed in any length with rubber joints fixed to walls with Stack clamps out of 50 mm by 5 mm flat iron and 6mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roofcomplete all as specified and directed. |
| 83 | S & F for PVC (SWR) bends any radius bore of dia 110mm with access door complete all as specified and directed. |
| 84 | S & F for PVC (SWR) bends/ Shoes any radius bore of dia 110mm complete all as specified and directed. |
| 85 | S & F for 75mm PVC (SWR) bends any radius bore of diawith access door complete all as specified and directed. |
| 86 | S & F for 75mm PVC (SWR) bends any radius bore of diacomplete all as specified and directed. |
| 87 | S & F for 110 mm PVC (SWR) branch piece,Single Tor Y) equal or unequal ofwith access door complete all as specified and directed. |
| 88 | S & F for 75 mm PVC (SWR) branch piece,Single Tor Y) equal or unequal ofwith access door complete all as specified and directed. |
| 89 | S & F for 110 mm PVC (SWR) vent cowl complete all as specified and directed. |
| 90 | S & F in repairPVC (SWR) floor trap, 75mm dia plainwith grating including jointing with solvent cement complete all as specified and directed. |
| 91 | S & F for 50mm dia bore pipe low density LDPE fixed to wall, ceiling or in floors etc complete all as specified and directed. |
| 92 | M & L for SFRC cover extra heavy duty [rectangular] of grade [EDH-35] of size 900mmx450mmxx75mm Precast cement concrete 1:2:4 type B-1 (20mm graded aggregate) as in cover slabs (for man holes etc)set in Cement mortar 1:4 complete all as specified and directed. |
| 93 | S & F for solidPVC door frame of size 95mm x 47mm made out of 5mm prelam colour PVC sheet reinforced with MS square tube, single side in opening as per specifications & drawings complete all as specified and directed |
| 94 | S & F for factory made solid PVC moulded door shutter, 28 to 30mme thick (stiles), with 2,4 or 6 raised panel designed with 4mm thick moulded PVC sheet on front face and 4mm plain colour PVC sheet on back face as per specification and drawing complete all as specified and directed |
| 95 | Supply and fix for75mm size, Butt hinges, heavy weight, SS, and fixed complete all as specified and directed |
| 96 | Supply and fixaluminium handles cast type anodised for 100 mm complete all as specified and directed |
| 97 | Supply and fixaluminium handles cast type anodised for 150 mm complete all as specified and directed |
| 98 | M & Lfor Providing & injecting ATT chemical at the point of contact ofvoids in masonry wall and floor joins or perimeter of rooms using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed.Note:- Measurment to be consider only perimeter of wall and depth up 500 mm |
| 99 | S & F EWC Single piece incl flusing cistern of size 840x390x720mm,vitreous china of one pieceincluding cutting for and pinning in ends of fixing or erecting stand inclusive of waste pipe and seat cover and P / S Traps etc complete all as specified and directed.Make Jaquar Cat Part No- VGS-WHT-0207P or equivalent as specified in PS & as approved by AGE(I) |
| 100 | S & F in repairStainless steel Hand shower (health faucet )15 mm dia and 1.00 mtr longFlexible tube iand wall hook for fixing to walls complete all as specified and directed.Make -Jaquar Cat Part No ALD-573 or equivalent as specified in PS & as approved by AGE(I) |
| 101 | S & F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 102 | S & F in repair Anglular stop valve15mm dia of chromium platedfancy type any colour high pressure screwed for iron pipe and fixed complete all as specified and directed.Make -Jaquar Cat Part No ALI-85053 or equivalent as specified in PS & as approved by AGE(I) |
| 103 | S & F in repair 15mm bore dia chromium platedfancy type Bib taps, with capstan head or fancy type knob type , screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.Make -Jaquar Cat Part No ALI-85037 or equivalent as specified in PS & as approved by AGE(I) |
| 104 | S & F in repairTable top Wash basins, vitreous china round type of 160x495x365mm, including cutting for and pinning in ends of brackets or erecting stand inclusive of waste pipe complete all as specified and directed.Make Jaquar Cat Part No- SLS-WHT-0558 or equivalent as specified in PS & as approved by AGE(I) |
| 105 | S & F in repair for Pillar cock of Single lever Wash hand basin mixer tall boy with 140mm extension Body fixed spout without popup waste system with 600mm longbraidedhoses Complete all as specified and as directed. Make Jaquar Cat Part No- DRC-37005B or equivalent as specified in PS & as approved by AGE(I) |
| 106 | S & F for CPToilet Roll Holder all as specified and as directed. Make Jaquar Cat Part No- AKP-35751P or equivalent as specified in PS & as approved by AGE(I) |
| 107 | S & F for CPtowel Ring squareall as specified and as directed. Make Jaquar Cat Part No- AKP-36721P or equivalent as specified in PS & as approved by AGE(I) |
| 108 | S & Ffor Glass shelf assmbly 600 mm long and approved by Engineer-in-Charge Make Jaquar Cat Part No- ACN-1171N or equivalent as specified in PS & as approved by AGE(I) |
| 109 | S & Fin repair cabinet mirror of with approved colour complete including necessary fixing arrangementscomplete all as specified and as directed. |
| 110 | S & F for CP tubular towel rail, 20mm dia, \"D\" type, 60cm long between flanges made of brass chromium plated complete all as specified and as directed. |
| 111 | S & F for Corner glass shelf withbrackets 300 x300mmand approved by Engineer-in-Charge Make Jaquar Cat Part No- ACN-1173 or equivalent as specified in PS & as approved by AGE(I) |
| 112 | S & F for Soap dish Holder and approved by Engineer-in-Charge Make Jaquar Cat Part No- ACN-1131N or equivalent as specified in PS & as approved by AGE(I) |
| 113 | S & Fin repairs 2mm thick Fabric vertical blindes with sliding track with cable and fixing hook etc andapproved colour etccomplete all as specified and as directed. |
| 114 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 115 | S & F Hangers 6 mm dia G.I (upto 1200 mm length) adjusting level fixed to roof slabs by means ofceiling cleats made out of G.I) flats 40x3 mm size60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and directed. |
| 116 | S & F Anodised aluminum snap grid frame work as required grid (size of grid 605x605 mm) ceilingcomplete all as specified and directed. |
| 117 | M&L for 6 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws for fixing in 600 mm x 600mm grid complete all as specified and directed.Note:- Frame work for ceiling shall be measured and paid separately. |
| 118 | M&L for \"GI frame work for seamless ceiling comprising of GI parameter channel 0.55 mm thick with two uneaqual glanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm c/c /intrmediate channel 0.9 mm thick having two equal glanges of 15 mm each and including web of 45 mm suspended from soffit at approx 900 mm c/c with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 mtr length) of 0.55 mm thickness having kurledof 50 mm and flenge of 26 mm each with lips of 10.5 mm fixed to the interediate channel with connecting clips across the intermediate channels at457 mm centre to centre complete all as specified and directed. |
| 119 | M&L for 8mm thick Seamless calcium silicate ceiling made out of 1800x1200 mm size board of siliceous and calcareous material reiforced with cellulosefibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having fillips headwith under haed cutter at 200 mm centre to centre,including finishing th ejoints of face board with specially formulated joiting compound and 48 mm wide fibre tape to provide seam les finish and design as approved by EIC (Frame work for ceiling shall be measured and paid separately) complete all as specified and directed. |
| 120 | M & Lfor preparation of newlycalcium silicate boardsurfaces of ceiling and applying two coats of oil bound distemperover 2 coat ofbirla wall care putty Smart painting work carried through manufacturer as per PS clause complete all as specified and directed. |
| 121 | Supply and fixin repair for Aluminium composite panel (ACP) of approved shades of viva/ alucobond (classic sparkle colours) 3 mm thick exterior grade PVDF with foil thick of 0.25 mm & frame work made out from aluminium section of size (38x25mm)x1.5mm thickness supported on masonary /RCC with the held of MS bracket fixed with brick fastner/anchor fastner and groove filled with with 789 weather sillent of DOW coming etc fixed to main gates arches, porches, pillars etc. as per manufacturer instructions. complete all as specified and directed. Note: All work shall be carried out by approved applicator of manufacturer only. |
| 122 | M&L for Cutting and removingofUnserviceable AC Duct of size 1.20x0.90of building etc complete all as apecified and directed by Engr in Charge and making good in disturbed portion with brick work/ PCC 1:2:4 Type B1 or Plastering where disturbed surfaces complete all as specified and directed. |
| 123 | Removal of demolished materials/debris to a distance exc 1.50 KMbut n exc 5.00 KMof capacityof perload as per SSR part-IInotes complete all as specified and directed. |
| 124 | SCHEDULE \"A\" PART-II [ E/M WORKS] |
| 125 | Taking down old/existing DB/main switches of any size and making good distrubed surface of wall/floor etc complete by disconnecting all as specified and directed. |
| 126 | Taking down oldsub main wiring any type/size including making good disturbed surface all as specified and directed. |
| 127 | Material and labour for sub main wiring (concealed) complete with four single core 6 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 6 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed.Note: 5 run of 6 sqmm & one run of PVC conduit shall be measuredas single unit |
| 128 | Material and labour for sub main wiring (concealed) complete with two single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed.Note: 3 run of 4 sqmm & one run of PVC conduit shall be measuredas single unit |
| 129 | Material and labour for sub main wiring (concealed) complete with four single core 10 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25/32 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 10 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed.Note: 5 run of 10 sqmm & one run of PVC conduit shall be measuredas single unit |
| 130 | Taking down carefully any type point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and as directed. |
| 131 | Material and labour for point wiring (concealed) on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit heavy grade accessories, ISI marked, 19/20 mm dia including all accessories, concealed in wallsby cutting chases using machine and making good the disturbed surface, with and including suitable 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed. |
| 132 | (a) One light point controlled by one switch |
| 133 | (b) One fan point controlled by one switch |
| 134 | (c) One switch socket outlet modular type 3 pin 6 amp on same board. |
| 135 | (d) One switch socket outlet modular type 3 pin 6 amp on independent board. |
| 136 | All as per item No 128 above but 2.5 sq mm cable sizewith 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 16 Amps on independent board all as specified and as directed. |
| 137 | Supply and Fix Switch modular type, single pole one way 6 Amps complete all as specified and as directed. |
| 138 | Supply and Fixmodular type electronic step regulator for ceiling fan 100 Watts , complete all as specified and as directed. |
| 139 | Supply and Fix socket modular type6 Amps 2/3 pin combined 2 module complete all as specified and as directed. |
| 140 | Material and labour for ceiling rose, surface Bakelite, 65 x 50 mm, two to three terminals all as specified and as directed. |
| 141 | Supply and Fix Switch modular type, single pole one way 16 Amps complete all as specified and as directed. |
| 142 | Supply and Fix socket modular type6/16 Amps 2/3 pin combined 2 module complete all as specified and as directed. |
| 143 | Supply and Fix for Modular white cover plate with frame, 3 Module complete all as specified and directed. |
| 144 | Supply and Fix for Modular white cover plate with frame, 6 Module complete all as specified and directed. |
| 145 | Supply and Fix for Modular white cover plate with frame, 8 Module complete all as specified and directed. |
| 146 | Supply and Fix for Modular white cover plate with frame, 3 Module complete all as specified and directed. |
| 147 | Supply and Fix for Modular white cover plate with frame, 6 Module complete all as specified and directed. |
| 148 | Supply and Fix for Modular white cover plate with frame, 8 Module complete all as specified and directed. |
| 149 | M&L Socket2 in 1, 3 pin, 5 Amp flush type universal complete all as specified and as directed. |
| 150 | M&L for switch piano flush type single pole, one way 5amp complete all as specified and as directed. |
| 151 | M&L for switch piano flush type single pole, two way 5amp complete all as specified and as directed. |
| 152 | M&L Switch socket combination 2 in 1, 3 pin, 5Amp flush type universal complete all as specified and as directed. |
| 153 | M&L Switch socket combination 5 in 1,5 and 15 Amp flush type universal complete all as specified and as directed. |
| 154 | Supply and fix recessed mounting 2 ft x 2 ft LED luminaries 36W or nearest higher wattage 6500 K with driver suitable for amtrong/grid ceiling with glare free lightLED etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 155 | Supply and fix motion sensor 2 ft x 2 ft LED luminaries 36W or nearest higher wattage 6500 K with driver suitable for recessed/surface fitting with glare free lightLED etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 156 | Supply and fix recessed mounting 1 ft x 1 ft LED luminaries 18W or nearest higher wattage 6500 K with driver suitable for amtrong/grid ceiling withglare free lightLED etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 157 | Supply and Fixwall mounted LED batten with decorative end capof capacity 4feet 20W or nearest higher wattage ,2500 lm ,6500 K suitable for Surface, Wall & Conduit mounting complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and lamp complete all as specified and directed internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed. |
| 158 | Supply and fix LED light fitting2 feet,10 W or nearest higher wattage,230v,suitable for Surface, Wall & Conduit mounting, with extruded aluminium housing, with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed. |
| 159 | Supply and fix sheet metal enclosure powder coated double doorfor Distribution Board, PHASE SELECTORVTPN 6 way DB with Degree of ProtectionIP 43 suitable for 200 AmpsBus Bar including taking down old complete all as specified and as directed. |
| 160 | Supply and fix MCCBs 100 Amps, 415V,16KA, TPN including making necessary incoming and outgoing electrical connection with suitable size of copper lugs completeall as specified and as directed. |
| 161 | Supply and fix MCB TP 32 Amps, C curve with breaking capacity 10 KA including making necessary incoming and outgoing electrical connection with suitable size of copper lugs completeall as specified and as directed. |
| 162 | Supply and fix sheet metal enclosure powder coated double doorfor Distribution Board, SPN 8 way DB with Degree of ProtectionIP 43 , Detachable Gland Plate, Box Insertion Marks, Circuit Identification Label, Neutral Link, Earth Link, Tin Plated Copper Bus Bar complete all as specified and as directed. |
| 163 | Supply and fix MCB SPN 40 Amps, C curve with breaking capacity 10 KA including making necessary incoming and outgoing electrical connection with suitable size of copper lugs completeall as specified and as directed. |
| 164 | Supply and fix MCB SP 10-32 Amps, C curve with breaking capacity 10 KA including making necessary incoming and outgoing electrical connection with suitable size of copper lugs completeall as specified and as directed. |
| 165 | Material and labour for earthing complete with galvanised steel earth plate electrode60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 4 mm GI wire as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3in SSR part 1 connected to earthing test point, including 20 mm GI pipe (Medium grade) for watering and 15 mm GI pipe (Medium grade) for protection of earth wire andetc..including testing on completion, PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wire mesh, funnel, lugs and charcoal, salt etc all as applicablecomplete all as specified and as directed by the Engineer-in-Charge. |
| 166 | Material and labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire all as specified and as directed. |
| 167 | Taking down wall fan any type any size dismantling blades and removing E/ fan and blades including winding, repairing and complete servicing, painting of fan & deposite to MES store complete all as specified and as directed by the Engineer-in-Charge. |
| 168 | Supply and fix in repair of air termination copper rod 12mm dia 300mm long for lightening conductor with epoxy insulators of suitable size of air termination including taking down oldcomplete all as specified and as directed by the Engineer-in-Charge. |
| 169 | M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw including taking down old complete all as specified and directed. |
| 170 | M&L for painting with synthetic enameled paint with black colour on wall of size 200x150mm and writing with wite colour for earth test result with date & year complete all as specified and directed. |
| 171 | Material and labour for 20x3mm copper stripfixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation etc. including taking down oldall as specified and as directed. |
| 172 | M/L for providing earthling complete withcopperplate electrode 600 mm x 600 mm x3.15mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level ,Alternate layers of charcoal)& common salt Crystal andconnected to Copper earth strip 20x3mm by means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly all as shown in electrical plateNo. 3of SSR Part I of 2009 & testing complete including 40mm dialight grade GI pipe up to 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box ,including 20 mm bore water pipe medium gradeGI Tubing includingGI Funnel , wire mesh etc. ( NOTE :- Earth continuity conductor and GI protection pipe beyond 7.5m shall be measured and paid under the respective items ).all as directed by Engineer- in charge. |
| 173 | M&L for taking down of split type Air conditioner any capacity from any height& make Shifting to other location, refixing indoor & outdoor unitincluding duly making holes into wall for insertion of copper pipe, drain pipe and 3 core cable, and making good the disturbed surfaces complete and including servicing the entire unit complete all as specified and directed. |
| 174 | M&L for replacement of unserviceable UPVC conduit pipe 20mm dia to drain out pipe including all acessories and taking down the existing one,with fixing arrangement on wall/celing etc complete all as specified and directed. |
| 175 | Supply only Refrigerant Gas R-22complete all as specified and directed. |
| 176 | M & L for single pole and neutral (SPN) sheet metal enclosure with a two pin and earth plug and socket complet with one single pole MCB 240 V, 20/32 amp complete all as specified and as directed by the Engineer-in-Charge. |
| 177 | Supply and fixing Copper pipe 1/2\" diawith foam insulation including connecting, taking down old complete all as specified and directed. |
| 178 | Supply and fixing Copper pipe 1/4\" diawith foam insulation including connecting, taking down old complete all as specified and directed. |
| 179 | Supply and fixing three core flexible cord copper wire of size 2.5Sqmmcomplete all as specified and directed. |
| 180 | Supply and fixing of GI powder coated brackets ,for fixing of split AC\"s including grouting with suitable size fastners complete all as specified and directed. |
| 181 | Dismantling the burnt out transformer from the 3/5 KVA capacity stablizer of any make and rewinding with super enameled copper wire including provision of all material and refixing the stablizer and testing to the entire satisfaction complete all as specified and directed. |
| 182 | Schedule of credit amount brought back from Ser Page No.48- Rs. 78,519.00 will be deducted from the above quoted amount to derive the contract sum. SIGNATURE OF CONTRACTOR |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy