Tender For Repair And Maintenance Of Dg Set Amf Panels And Connected Work And Repair And Maintenance Of Fire Fighting System At Dhq 3 Mangalore Under Ge(I)(Cg)Goa, mangalore-Karnataka

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Dg Set Amf Panels And Connected Work And Repair And Maintenance Of Fire Fighting System At Dhq 3 Mangalore Under Ge(I)(Cg)Goa. Submission Date for this Tender is 22-11-2023. Fire Fighting Consumable Tenders in mangalore Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

40344457
Corrigendum : Tender For Repair And Maintenance Of Dg Set Amf Panels And Connected Work And Repair And Maintenance Of Fire Fighting System At Dhq 3 Mangalore Under Ge(I)(Cg)Goa
Open Tender
Indian
Karnataka
mangalore
22-11-2023

Tender Details

Repair And Maintenance Of Dg Set Amf Panels And Connected Work And Repair And Maintenance Of Fire Fighting System At Dhq 3 Mangalore Under Ge ( I ) ( Cg ) Goa

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 33800.0 /-
Tender Value
INR 16.89 Lakhs /-

BOQ Items

Name of Work:REPAIR AND MAINTENANCE OF DG SET AMF PANELS AND CONNECTED WORK AND REPAIR AND MAINTENANCE OF FIRE FIGHTING SYSTEM AT DHQ 3 MANGALORE UNDER GE(I)(CG) GOA
Sl. No. Item Description
1SCH A PART -I [REPAIR AND MAINTENANCE OF DG SET AMF PANELS AND CONNECTED WORK] Carrying out "B" check to DG Set of Cap 200 KVA, Make : Cummins by replacement ofOil filter, Fuel filters, Bypass filter and air filter assy and including Adjusting free play of fan belts, and noticing for any abnormal sound occurring in engine and making Minor adjustments in the engine, Fuel feed pump, starting control panel and replacement of any other minor parts other than engine overhaulingcomplete all as specified and directed. [Note:- The spares required for the servicing will be measured and paid separately under relevant item. The servicing of the Engine shouldbe carried out by Authorized Service dealer of Cummins]
2Supply only the following spares Accessoriesrequired for servicing DG Set of Cap 200 KVA, Make : Cummins Engines complete all as specified and directed.
3(a) Oil Filter
4(b) Fuel Filter
5(c) Coolent
6(d) Air Filter
7(e)Seal-O Ring
8(f) Lub oil filter cartridge
9All as per item No 1.00 above but of Capacity125 KVA Mahindra Engine and 100 KVA Make : Cummins Engines complete all as specified and directed.
10Supply only the following spares Accessoriesrequired for servicing of 125 KVA Mahindra Engine and 100 KVA Make : Cummins Engines complete all as specified and directed.
11(a) Oil Filter
12(b) Fuel Filter
13(c) Coolent
14(d) Air Filter
15(e) Water seperator
16(f) Bypass element
17(g)Seal-O Ring
18(h) Lub oil filter cartridge
19All as per item No 1.00 above but of Capacity 62.5 KVA, 50 KVA and 40 KVA, Make : Mahindra complete all as specified and directed.
20Supply only the following spares Accessoriesrequired for servicing of the DG Set of Cap 62.5 KVA, 50 KVA and 40 KVA Make : Mahindra Engine complete all as specified and directed.
21(a) Oil Filter
22(b) Fuel Filter
23(c) Coolent
24(d) Air Filter
25(e) Water seperator
26(f) Lub oil filter cartridge
27All as per item No 1.00 above but of Capacity20 KVA, Make : Kirlosker and 15 KVA, Make : Kirlosker and Cummins complete all as specified and directed.
28Supply only the following spares Accessoriesrequired for servicing of the 20 KVA DG Set Make : Kirlosker Engine and 15 KVA DG Set Make : Kirlosker and Cummins complete all as specified and directed.
29(a) Oil Filter
30(b) Fuel Filter
31(c) Coolent
32(d) Air Filter
33(e) Water seperator
34M & L Taking down the defective self starter Assembly of12 Volt from the Engine and dismantling the starter and taking out burnt stator winding, rewinding the startor with super enemelled copper wire of suitable guage incl all insulation material incl Carbon brush holder, Bearings, Field coiland refixing to the engine of capacity 100/125/200 KVA complete all as specified and directed.
35M & L Taking down the defective self starter Assembly of12 Volt from the Engine and dismantling the starter and taking out burnt stator winding, rewinding the startor with super enemelled copper wire of suitable guage incl all insulation material incl Carbon brush holder, Bearings, Field coiland refixing to the engine of capacity 62.5/50/40/20/15 KVA complete all as specified and directed.
36Repair/ Repalcement of solonoid valve of self starter 12 volts DC for 100 to 200 KVA DG Set complete all as specified and directed.
37All as per item No 11.00 above but of capacity 62.5/50/40/20/15 KVA DG set complete all as specified and directed.
38M & L in repairs and calibration of injector assembly for 100/125/200 KVA DG setincluding replacemet of nozzle, spring, barrel plunger, injector cupcomplete and refitting to orginal position duly changing the worn out nut, bolt/studs etc complete all as specified and directed.
39All as per item No 13.00 above but of capacity 62.5/ 50/ 40/ 20/ 15 KVA DG complete all as specified and directed.
40M & L repairs to Radiator assly of DG set 200/125/100 KVA , by dismantling from engine , taking out the leaking cooling fins and repairs by bracing the pipe,and refixing on engine and tesing complete all as specified and directed.
41All as per item No 15.00 above but of capacity of 62.5 KVA/ 50 KVA/ 40 KVA DG set complete all as specified and directed.
42All as per item No 15.00 above but of capacity of 20 KVA and 15 KVA DG set complete all as specified and directed.
43Draining out Lub oil from the oil pan assy of DG set 200/125/100 KVA and keeping aside for reuse and taking down oil pan assy complete from the engine block for cleaning the eitire oil pan with recommended solution and resembling the oil pan after replacement of gasket oil pan (Lub oil shall be examined for reuse by Engr in charge.However if the oil is found unsuitable for reuse, fresh oil shall be measured and paid separaetly under respective item complete all as specified and directed.
44All as per item No 18.00 above but of capacity 62.5 KVA/ 50 KVA/ 40 KVA DG set complete all as specified anddirected.
45All as per item No 18.00 above but of capacity 20 KVA/ 15 KVA DG set complete all as specified and directed.
46M & L for scrapping out oldrusted paint, rust and dust on 200 KVA/ 125 KVA/ 100 KVA/ 62.5 KVA /50 KVA and 40 KVA DG sets aquastic enclossure, base and necessary tinkering / welding work to make good the external surface and apply two coat of synthetic enamelanti- corrosive paint of matching colour as per existing and re writing the specific make and description mention on the body of DG Set etc in prescribed size complete all as specified and directed.
47All as per item No 21.00 above but of Capacity20 KVA and 15KVA complete all as specified and directed.
48M & L for preparing external surfaces of LT DG change over panel /pump panel at various sub stations/locations completely removing the all dust and dirt including rust and applying one coat of approved existing shade of synthetic enamel painting including writing the required details as existing complete all as specified and directed.
49M & L for Lubrication oil recommend for Cumins, Kirloskar and Mahindra engine(15/20 W 40) complete all as specified and directed.
50Supply only distilled water best quality suitable for lead acid battery complete all as specified and directed.
51S & F in replacement battery 12V, 100 AH (Maintenance free) for DG Set complete all as specified and directed.
52M & L for power contactor of AMF panel of DG Set of suitable Amp 3 phase, 415 Volts conforming to the parameters of existing contactor after disconnection the existing UNSV power contactor from the position complete all as specified and directed.
53M & L for Engine start/ over speed/ Stop relay, Three kickattempt timer relay suitable for mounting inside AMF panel of various cap DG Set, 12/24 Vdc conforming to the parameters of existing relay including taking down old Uunserviceable relay complete all as specified and directed.
54M & L for replacement of AC Digital voltmeter 0-500 Volts of suitable size complete all as specified and directed.
55M & L for replacement of AC Digital Ammeter 0-200 of suitable size complete all as specified and directed.
56S & F in repairs MCCB 4 Pole, current rating 160 Amps, breaking capacity 36KA, 415 V, 50 HZ. Including taking down old unserviceable MCCB complete all as specified and directed.
57S & F in repairs MCCB 3 Pole, current rating 125 Amps, breaking capacity 16 KA, 415 V, 50 HZ.Including taking down old Uunserviceable MCCB complete all as specified and directed.
58S & F in repairs MCCB 3 Pole, current rating 100 Amps, breaking capacity 16 KA, 415 V, 50 HZ.Including taking down old unserviceable MCCB complete all as specified and directed.
59M & L for dismantling of old Unserviceable Earthing complete and making good disturbed surface by removing all material from site complete all as specified and directed.
60Earthing complete with galvanized iron earth plate electrode 600x600 x6.0mm thick buried directly in ground( earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level ,connected to galvanized iron strip of size 32 x 6 mm as earthing lead by means of nuts and bolts check nuts and washersof galvanized iron connected to test point, GI tubing 40mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt,Ci cover with suitable handle,PCC pit 1:2:4including earth work in any type of soil and connecting to earthing test point/panel and testig on completion all as shown on electrical plateNo -3 of SSR 2009- Part 1 complete all as specified and directed.
61S & F in repairs PVC insulated 10.00 Sqmm Copper Battery lead 0.50 Mtr Long with brass end terminals complete all as specified and directed
62M & L for decoupling the alternator of 100/125 KVA from the engine and taking out alternator from base plate and carrying the u/s alternator to local market incl dismantling the entire alternatortaking out burnt enamelled copper wire, preparing the statorfor rewinding andrewinding the stator with super enamelled copper wire of superior quality incl application of insulating material, cotton tapes and suitableheat treatment, transporting back to site and refixig to the engine from retrieved position complete all as specified and directed.
63M & L for Disconnection of engine electrical wiring from the DG set of 100/125 KVAand rewiring of 100 KVA DG Set complete with copper wire as per the existing guage and making all connection complete including replacement of indicating lamps, push button , toggle switch etc complete all as specified and directed.
64M & L for replacement of unserviceable Asbestos rope of DG Set complete all as specified and directed
65S & F AVR or Automatic voltage regulator suitable for alternator 100/125/200 KVA 415 Volts 50 Hz Ac electric supply and output voltage 120 Volts 8 Amp DC Voltage complete all as specified and directed.
66SCH A PART -II [REPAIR AND MAINTENANCE OF FIRE FIGHTING SYSTEM] M & Lfor refillingfireextinguisherforfollowingtypeand capacity complete all as specified and directed.
67(a) Dry Chemical Powder (DCP) type Fire extinguisers : stored pressure - 9 kg capacity complete all as specified and directed.
68(b) Carbon Dioxide (CO2) type Fire extinguisers : - 4.5Kg capacity complete all as specified and directed.
69(c) Aqueous Film Forming Foam (AFFF ) type Fire extinguisers : - 9 liters capacity complete all as specified and directed.
70M & L Painting fire hydrant pipe line up to 100mm dia by scrapping old rusted paint and applying one coat of red oxide primer and two coats of synthetic enamel paint of fire red colour including marking symbol for fire hydrantflow,complete all as specified and directed.
71M & L for taking down carefully electric driven monoblock pump of capacity 12.5 HP/9.3 KW 3-phase 415v, 50Hz, AC from foundation/ coupling, transporting to civil workshop, opening the motor,Checking the insulation value of the windings, insulating the winding with same class of insulation, painting with one coat of synthetic enamel paint as per colour code and return back to site and re-installing the motor and connecting to the pump, testing the motor for satisfactory performance complete all as specified and directed.
72M & L for opening and servicing/overhauling the electric driven monoblock pump and motor 12.5 HP and replacing the defective ball bearing,greasing replacing the bur nout gland rope, studs, nuts, bolts, washers ,air releasing valve, rubber gasket0, metal filling, turing/ grinding and balancing the shaftetc. and refixing complete all as specified and directed.
73S & F Dialtypepressuregauge (4"Dia)0-21 Kgs/cm2 including taking down old unserviceable item complete all as specified and directed.
74S & F Single pressure switch, universal type to suit the system including taking down old unserviceable item complete all as specified and directed.
75S & F Gun metal air release valve 25mm dia including taking down old unserviceable item complete all as specified and directed.
76M & L with Replacementof Gun metal fire Hydrant valve with 5mm flanged inlet and 63 mm female single instantaneous outlet complete with Lug & Chain as per IS 5290 Hydrostatically tested to 21 Kgf/cm2 of pressure having a flow rate of 900 LPM at 7Kgf/m2 complete all as specified and directed.
77M & L with Replacement of Non-perculating flexible fire fighting delivery hose fire hose 63 mm dia confirming to Type A of IS:636, 15 meter length includinggunmetalheavydutypairofmaleandfemalecouplings complete all as specified and directed.
78M & L with Replacement of swiniging hose reel of20 mm dia wall mounted type comprising rubber hose 30 m long high pressure double braided bearing IS 444, PVC shut off nozzle and 25 mm gunmetal valve conforming to IS 884 and connected to wet raiser complete all as specified and directed.
79M & L with Replacement of gunmetal branch pipe with male threaded nozzle of 15mm and male instantaneous inlet of 63 mm dia as perIS : 903 complete all as specified and directed.
80S & F in repairs cast iron sluice valve 100 mm dia with flanged ends confirming to IS 14846 type PN 1.0 with brass spindle, Cast Iron wheel etc. including all accessories complete all as specified and directed.
81M & L Painting of fire control cabinet out door type size 0.5 x 0.5 x 0.3 meter with two coatsof synthetic enamel paintoveracoatredoxideprimerbyspraypaintincluding scrapping out old rusted paint and necessary snickering and making complete all as specified and directed.
82Repairof microprocesserbasedaddressable firealarm controlpanel,havingsixloopdatacard,battery,LCDpanel,buzzers and software program etc, including testing complete all as specified and directed. [Note: The unit rate quotedshall includefor regular inspection, /servicing of loop wiring, heat / smoke detectors, responseindicator,MCP,soundercumscobwithcontrolmodule]
83S & F manual call point resettable type complete all as specified and directed.
84S & F addressable electronic sounder cum storbe with control module with taking out old unserviceable complete all as specified and directed.
85M & L for Repairs to CI sluice valves flanged type size 80/100 mm dia by taking out gland sleeve, check nut spindle, gate etc. and cleaning the valve by removing all scales and reassembling the valve with new packing nut and bolts including painting with one coat of synthetic enamel paint complete all as specified and directed.
86M & L for Repairs to CI Non return valves flanged type size 80/100 mm dia by opening the cover and cleaning the valve by removing all scales, dirt etc and reassembling the valve with new packing nut and boltsincluding painting with one coat of synthetic enamel paint complete all as specified and directed.
87S & F rubber bush for pump coupling suitable for 12.5HP/9.3 KW motor complete all as specified and directed.
88M & L for replacement of Glass 3 mm thick of size 12 x 18 inch for indoor/outdoor fire hydrant boxes/ panels as per site requirement by taking down old broken glass complete all as specified and directed.
89M & L for Wiring for circuit/submain wiring with two runs of4 Sq mm alongwith one run of 4 Sq mm earth wire multi standard copper conductors, 1100 volts grade in exsiting surface/recessed steel /PVC conduit including taking down old unserviceable sub main wiring/Ciruit wiring complete all as specified and directed.
90All as per item No 61.00 above but in 1.5 Sqmm complete all as specified and directed.
91M & L for Replacement of old rusted fire bucket stand and Fire buckets madeup of Alloy steel/ iron, painted with bright red paint and is stenciled with the word a Fireon it, Square in shape having arrangement for hanging four (4) fire bucketscomplete all as specified and directed.
92M & Lfor attending breakdown of 80/100 mm dia pipe line bursting/cracks including broken pipe pieces of various sizes through gas cutting or manual cutting as required at site and providing new CI/MS/GI pipes of required length (not more than 2m) and removing out the damaged CI pipe and inserting necessary specials such as flanges etc as required at site including testing for the leakages of flange joints for 100mm dia MS/CI pipes and including any type of excavation/ cutting of hard standing/road/returning filling complete all as specified and directed.
93M & L for testing of all equipment and checking ofwater pressure by starting pump in auto and mannualas per site requirement once in a month in the presence of Engineer -in-charge complete all as specified and directed. [Note: Payment shall be made only after production of Test report duly signed by all concern.)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail