Tender For Additional /Alternator To Bldg No P-21, P-183 And Car Parking Shed Under Age B/R Ii At Chandimandir, chandimandir-Haryana

Military Engineer Services-MES has published Tender For Additional /Alternator To Bldg No P-21, P-183 And Car Parking Shed Under Age B/R Ii At Chandimandir. Submission Date for this Tender is 18-11-2023. Shed Construction Tenders in chandimandir Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

40333029
Corrigendum : Tender For Additional /Alternator To Bldg No P-21, P-183 And Car Parking Shed Under Age B/R Ii At Chandimandir
Open Tender
Indian
Haryana
chandimandir
18-11-2023

Tender Details

Additional / Alternator To Bldg No P-21, P-183 And Car Parking Shed Under Age B / R Ii At Chandimandir

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work: ADDN /ALTN TO BLDG NO P-21, P-183 AND CAR PARKING SHED UNDER AGE B/R II AT CHANDIMANDIR
Sl. No. Item Description
1Demolition of reinforced cement concrete, reinforcement cut as required to facilitate, in any position not specifically provided for, complete all as specified and directed.
2Demolition of plain cement concretein ground floor and paving n.exc 15cm thickness below or above ground level complete all as specified and directed.
3Taking down cement plaster / terrazo of any description from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete, all as specified and directed.
4Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
5Brick work with sub class ‘B’ bricks, old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed.
6Brick work with sub class ‘B’ bricks, old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
7Brick work with sub class ‘B’ bricks ofold size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed.
8Rendering 15mm thick in Cement and Sand mortar 1:4 overfair faces of brick / concrete ,finished even and smooth without using extra cement, complete all as specified and directed.
9Rendering 10mm thick in Cement and Sand mortar 1:6 overfair faces of brick / concrete ,finished even and smooth without using extra cement, complete all as specified and directed.
10Rendering 15mm thickon fair faces of brick worksurfaces, finished even and fairin cement mortar (1:4), inclunding using water proofing compound, complete all as specified. Note : WPC shall be measured and paid separately.
11Supply only integral water proofing compound (ISI Marked) complete all as specified & directed.
12Preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer , complete all as specified and directed.
13Three coats of white wash on new plastered surfaces of walls including preparation of new plastered surfaces, complete all as specified and directed
14One coatof white wash on old surfaces of wall including preparation of surfaces, complete all as specified and directed
15Complete removal of existing treatment by using of wire brush /mechanical grinder including washing , rubbing down and stopping of distempered or painted surface and applying two coats of cement base paint over a coat of alkali resistant primer on walls,complete all as specified and directed.
16Pre-painted galvalume aluminum zinc coating (AZ-70) GI based corrugated steel sheet 0.50mm thick in any colour and patteren as approved by the GE of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, i complete all as specified and directed.
17Pre-painted galvalume aluminum zinc coating (AZ-70) GI based plain steel sheet 0.50mm thick in any colour and patteren as approved by the GE of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed.
18Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 , complete all as specified & directed by Engineer-in-Charge.
19Rolled mild steel work as in roof trusses(framed) trussed,purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc , Gde-Fe-410-S,complete all as specified & directed.
20Preparation of new or previously untreatedsteel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of red oxide, complete all as specified and directed.
21Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified.
22Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed.
23Steel rolling shutters (1 mm thickness of lath) without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: gear operated type with bevel gear box and crank handlecomplete all as specified and directed Note : size of each gate exc 7.5 sqm but n.exc 12 sqm
2440mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in flooring, finished even and fair including finishing surfaces by brooming/ Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green, including demolitionof old PCC complete all as specified and directed.
2575mm thick plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete, all as specified & directed.
26Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete, all as specified & directed.
2775mm thick PCC 1:2:4 type B-2 (using 40m graded crushed stone aggregate) as in sub base complete all as specified and directed.
28Coloured vitrifiedtiles, heavy duty,of size 600mm x 600mmx 15mm thick , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over15mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
29Steel window, box type, in repair primer coated, 1.00mm wall thickness, with glazing bar and openable shutter prepared to recieve sheet glass, complete including cutting holes, four Nos. for each window and making good dismantled portion in PCC (1:2:4) type B-1. including following fittings welded to frame/ shutter complete all as specified and directed.:- (a) Hold fast 150mm out of 25x6mm flat iron made to shape- 04 Nos. each window (02Nos. on each side). (b) Handle of "Z" section 20mmx25mm, 100mm long- 01No. each leaf. (c) MS tower bolt 150mm long- 02 Nos. each leaf. (d) "Z" section 20mmx25mm, 100mm long stopper 01 No. each leaf. (e) Cleat 55mm long of hollow square section 15mmx15mm of 24 guage wall thickness, welded to hinge of 55mm size 01 No. per leaf. (f) MS box type hinges of 75 mm size- 02Nos. per leaf. (g) Fabrication & fixing complete. Note: Glass panes & painting shall be measured & paid separately under respective item.s. Design shall be approved from Engr-in-Charge as existing at site and all as per Drawingbefore fabrication and bulk order to the manufacturer.
30All as per serial item No 29hereinbefore but without glazinf bar.
31Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples, complete all as specified and directed.
32Sheet glass 3mm thick, ordinary quality and glazing with oil putty in square, area not exc 0.5 sq. mtr in each pane,complete all as specified and directed.
33Surface excavation not exceeding 30 cm deep and averaging 20 cm deep and getting out in hard/dense soil, complete all as specified and directed.
34Excavation in trenches in any type of soil, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier hole etc. and getting out, complete all as specified.
35Excavation in post holes (or similar hole) each in ant type of soil n.exc 0.50 cu m getting out, returning, filling and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, watering and removing surplus spoil at a distance not exc 50 metre and making good surfaces complete all as specified and directed.
3650mm thick PCC 1:3:6type C-1 using 20 mm graded stone aggregate laid in alternative bays as in plinth protection including finishing the surface even & fair & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weightall as specified & directed by Engineer-in-charge.
37Form Work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter to give rough finish to flat surfaces complete all as specified and directed.
38Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socketor power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete all as specified and directed.
39Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new steel sunken boxes 1.2mm thickness covered with provision of3mm thick plastic laminated sheet, comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed.
40All as per serial item 39 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed
41All as per serial item 39 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed
42All as per serial item 39 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
43Switch piano, flush type, 6 amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge
44Switch piano, flush type, 16 Amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge
45Sockets outlet multipurpose 2 in 1 pin, 6 and 6Amps flush type ISI marked all as specifiedand directed by Engineer-in-charge
46Sockets outlet multipurpose 2 in 1 pin, 6 and 16Amps flush type ISI marked all as specifiedand directed by Engineer-in-charge
47Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge.
48LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable sizefixed as in repair complete all as specified and directed.
49Slim LED lights fitting, 4 feet,1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
50Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed.
51Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.
52Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB"s ,MCB"s etcand removing from site, Complete all as specified and directed .
53TPN distribution board double door flush mounting with provisions for MCB TPN 4 way having IP 43 protection complete all as specified and directed .
54MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed.
55MCB, SPN , 240 volt,32Amps, 10 KA , "C" series including connection with suitable size aluminium / copper lugs complete all as specified and directed
56MCB , TPN/FP 40 to 100 Amp 415 volts, 16 KA , "C" series including connection with suitable size aluminium / copper lugs complete all as specified and directed
57MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , "C" series including connection with suitable size aluminium / copper lugs complete all as specified and directed
58Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including galvanised iron strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m (iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v)unit rate including protection pipe and GI strip 32x 6mm from top to earth plate upto 7.5 meter
59LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, including thermal management in multiple optics complete with IP 66 protection , as in repair complete all as specified and directed.
60GIbracket made of GI pipe Medium Grade of size 40mm dia 1.5 mtr length bend to shape of 120 degre fixed o pole/wall with clamp of size 50x6 of suitable length fixed with nuts/ bolts and 1.5 mtere long 1.5 sqmm 2 core flexible wire from connector / ceiling rose to light fitting fixed as in repair complete all as specified and directed.
61Exhaust fan, steel body AC single Phase. 230V of size 450m sweep, heavy dutywith, blades, and frame and louvers, complete all as specified and directed.
62XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 4 core, all as specified and directed.
6332mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection from approval make complete , all as specified and directed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy