Tender For Repairs Maintenances Of Dg Sets Fire Alarm Detection Systems Lt Panels Ug Cables Amf Panels And Connected Em Works Under Age Em Ii Of Ge Nw Vasco, vasco-Goa

Military Engineer Services-MES has published Tender For Repairs Maintenances Of Dg Sets Fire Alarm Detection Systems Lt Panels Ug Cables Amf Panels And Connected Em Works Under Age Em Ii Of Ge Nw Vasco. Submission Date for this Tender is 03-11-2023. Fire Alarm Systems Tenders in vasco Goa. Bidders can get complete Tender details and download the document.




Tender Notice

40332654
Tender For Repairs Maintenances Of Dg Sets Fire Alarm Detection Systems Lt Panels Ug Cables Amf Panels And Connected Em Works Under Age Em Ii Of Ge Nw Vasco
Open Tender
Indian
Goa
vasco
03-11-2023

Tender Details

Repairs Maintenances Of Dg Sets Fire Alarm Detection Systems Lt Panels Ug Cables Amf Panels And Connected Em Works Under Age Em Ii Of Ge Nw Vasco

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
INR 47.96 Lakhs /-

BOQ Items

NAME OF WORK : REPAIRS / MAINTENANCES OF DG SETS, FIRE ALARM DETECTION SYSTEMS, LT PANELS, UG CABLES, AMF PANELS AND CONNECTED E/M WORKSUNDER AGE E/M-II OF GE (NW) VASCO. (Tender ID No. 2023_MES_624316_1)
Sl. No. Item Description
1Dismantling the defective / burnt alternator of any capacity from the existing foundation and from Engine after removing all electrical connections, transporting to local workshop, opening and taking outburnt alternator stator winding, cleaning and then rewinding the stator assembly complete with super enameled copper wire as per existing original gauge of manufacturer and applying insulting varnishing of F class, baking in oven re-assembling the alternator, transporting back to site to its original position for re-installing the sae in position, carrying out ligament of complete DG set connecting up all electrical connections testing and commissioning complete. Note :- (a) Rate quoted shall be deemed to be inclusive of making good the disturbed surfaces, (b) The DG set shall be tested on available connected load for 4 hours at site upto the satisfaction of Engineer-in-Charge to achieve designed parameters and DHPP (N) shall be issued by department free for testing.
2Service Charges for carrying out the "B" Check maint from authorised rep or service engineer of the manufacturer of DG set of Engine Crompton Greaves/ Kirloskar-KOEL/ Cummins of follwing capacity engines including checking of air filter, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of fuel andoil filters, checking inlet & exhaust mainifold capscrews, checking of fan hub & water pump, topping up the level of existing engine oil or replacement of engine oil if reuired, coolant top up all as specified and directed. Note:- (a) Engine oil & Coolant top will be measured and paid seperately for the Engine as supply only items. (b) "B" checks shall be carried out on running of 500 Hrs or 6 months whichever is earlier. (c) If air filter found unserviceable, shall be measured and paid seperately.
3(i) DG set 200 KVA at NOFRA & NUWR Pump House- 02 Nos
4(ii) DG set 125 KVA at NOFRA Pump House & P-404 -02 Nos
5(iii) DG set 100 KVA at Mangoor & Varunapuri Pump House -02 Nos
6(iv) DG set 82.50 KVA at NUWR & BMF pump house- 02 Nos
7(v) DG set 320 KVA at Keerti Enclave MAP PH II Pump house & VAT site -02 Nos
8(vi) DG set 25 KVA at Sewage Pump House & DCRA Pump House -02 Nos
9(vii) DG set 20 KVA at New leading Pump house -01 Nos
10Replacement after draining out old engine oil and refilling new Engine Oil for DG set of any capacity complete all as directed and specified by Engineer-in-Charge.
11Refilling /topping up new collant for different capacity of DG sets complete all as specified and direced by Engineer-in-Charge.
12Refilling and topping up new distilled water with suitable mix of electrolyte in the batteries at various location of different capacity ofDG set batteries.
13S & F in repairs air filter both inner and outer for 100 - 125- 320 KVA Capacity DG set (Make of DG set - Crompton Greaves/Kirloskar-KOEl/ Cummins) all as specified & directed by Engineer-in-Charge.
14S & F in repairs air filter both inner and outer for 20-25-82.50KVA Capacity DG set (Make of DG set - Crompton Greaves/Kirloskar-KOEl/ Cummins) all as specified & directed by Engineer In Charge.
15Repair & overhauling of FIP of 20 to 320 KVA Capacity DG Set by taking out carefully and refixing after calibration at authosrised service centre/dealer including replacement of unserviceable worn out parts. Note:- Unservicieable major parts required for replacement shall be measured & paid seperately.
16Supply of follwing parts for serial item No:- 8 here in before. (a) Gasket set
17(b) Plunger
18(c)Main Shaft
19(d) Techno Shaft
20Supply and fixing in repairs rectifiers diode for 20 to 320 KVA DG sets suitable for DG sets Make of Crompton Greaves/Kirloskar-KOEL/Cummins
21Dismantling the old and unserviceable DG Set rubber hose pipe upto 2" dia and replacing the same with the existing size and equal length of any DG Set including both side hose clamp etc all as specified and directed.
22S & Fix solenoid swtich 3 phase 415 Volt (20 to 320 KVA) complete set as per existing size and make of any Capacity DG set all ass directed.
23Repair & overhauling of governor assembly of any capacity/Make DG set by replacing all worn out springs, nuts bolts gear , sleeves, rotary ballss etc and then proper calibration for proper functioning from authorised service centre /dealercomplete all as specified and directed by Engineer-in-Charge.
24S & F AVR suitable for any capacity DG set as in repair complete all as specified & directed by Engineer-in-Charge.
25Supply & fixing copper cable Multistranded suitable for 12/24 volts battery terminals , replacing the same with of existing size and equal length complete fixing with brass clamp at both ends including taking down of old one from the existing battery.
26Repair to self starter 12 Volts by taking out old burnt out copper winding and rewinding with super enammelled copper wire same gauge including replacement of U/s pinion , bush,solenoid coil, carbon brushes 7 tension spring complete in commisioning and testing all as specified & directed by Engineer-in Charge.
27All as per item No:- 16here in before but of 24 volts all as specified & directed by Engineer-in-Charge.
28Servicing of self starter of any capacity and voltage including dismantling the starter from engine opening by removing end covers, armature , field coil, gear arrangeent etc, replacing worn out nut bolt , gear wheel, checking and greasing all moving parts, reassembling complete and fixing back to its original position at site and testing complete
29S & F dynamo of 12 Volts for charging of battery as in repair complete all as specified & directed by Engineer-in-Charge.
30S & F dynamo of 24 Volts for charging of battery as in repair complete all as specified & directed by Engineer-in-Charge.
31Removing dynamo 12/24 Volts from DG set and transporting to local worlshop , opening dynamo, assembly, rewinding the burnt armature coil with super enamelledcopper wire of same gauge, reassembling and transporting back to site fixing and testing all as directed.
32Supply and fixing asbestos rope of 16/20 mm dia for silencer and with applying plaster of paris for any capacity DG Set as in repair complete all as specified & directed by Engineer-in-Charge.
33S & F in repair fan belt suitable for 20 to 100 KVA DG Set as per existing model and size including dismantling the old one.
34S & F in repair fan belt suitable for 125 to 320 KVA DG Set as per existing model and size including dismantling the old one.
35S & F in repairs panel mounting battery charger connected to panel of DG set with input voltage of 230 Volt and out put voltage 12 V DC hving Charging Voltage 13.5 Volt and option like boost /tickle/float and fuse protection including necessary wiring required for connection all as specified 7 directed.
36M & L connecting and commisioning lead acid battery 12 Volt 150 AH
37M & L connecting and commisioning lead acid battery 12 Volt 180 AH
38Supply & fixing in repairs battery terminals brass type suitable for any capacity battery all as specified & directed by Enginner-in-Charge.
39Dismantling the old unserviceable DG set diesel/oil prssure pipe of existing size and replacing the same with of existing size and equal length of any capacity DG set including both side hose clamp etc as directed.
40Cleaning of fuel tank of DG set of capacities 20 to 320 KVA any size capacity including draining out existing fuel, removing any foreign particles or sediments including checking of leak proof if found rectifying the same by necessary welding fabricating with sheet metal, matching with existing tank outer body , preparation of surface for painting with one coat of black synthetic enamel paint over a coat of red oxide primer and refilling the same as specified and direceted by Engineer-in- Charge.
41S & F in repair/replacement of harness wiring control wiring for 20 to 320 KVA DG set capacity for engine replacement of accessories of panel, relays, meter, toggle swtich etc all as specified and directed.
42S & F low lube oil level pressure cut off device suitable for diesel engine all as specified and directed by Engineer-in-Charge.
43S & F Oil pressure gauge 0-7 Kg/Cm as in repair complete all as specified and directed by Engineer-in-Charge.
44S & F Oil temperature gauge 40 C to 130 C as in repaircomplete all as specified and directed by Engineer-in-Charge.
45S & F water temperature safety control swtichas in repair complete all as specified & directed by Engineer-in-Charge.
46S & F water temperature meter 40 C to 105 C as in repair complete all as specified & directed by Engineer-in-Charge.
47S & F Ampere meter 30-0-30 DC as in repair complete all as specified and directed by Engineer-in-Charge.
48S & F in repairs bellow for 82.50 to 320 KVA DG set fixed in exhaust pipe of DG set along with connected accessories like rubber sheet , nuts, bolts all as specified & directed.
49M&L forearthing with steelearth plate electrode ofsize 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetable soil to the remaining 10%,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-In-Charge.
50S & F in repairs onload change over swtich 400 Amps 4 pole in without enclosureincluding necessary fixing arrangement in any description allas specified & directed by Engineer-in Charge.
51S & F in repairs onload change over swtich 200 Amps 4 pole in without enclosureincluding necessary fixing arrangement in any description allas specified & directed by Engineer-in Charge.
52Checking DG set of Capacity 20 To 320 KVA for any type of defects occurred in AMF panel/Control panel/ Starter / Engine / Alternator etc installed at various locations at SMA Varunapuri, DCRA, NOFRA Pump House, NUWR. And carry out necessary repairs in order to keep DG setserviceable at all time. Note:- (a) Minor items like worn out nut & bolts, Cable lugs etc shall be deemed to be included in the unit rate quoted., (b) Material required will be measured and paid under relvant items if required (c) Equipments/testing meters required for detecting faults shall be provided by the contractor.
53S & F in repairs power contactor 4 pole 415 V, AC 1 Current rating of 32 Amps suitable for AMF panel complete all as specified and as directed.
54S & F in repairs power contactor 4 pole 415 V, AC 1 Current rating of 130 Amps suitable for AMF panel complete all as specified and as directed.
55M & L replacemeent of silencer in repair of 82.5 KVA DG Set canopy type at NUWR & BMF pump house.
56M & L for replacement repair of malfunctional deep sea or digital type displaymounted on DG mini panel suitable for DG set showing the multiple digital parameters such as hour run, AMP, Voltage, Oil Level, Coolant level, temperature etc as per Kirloskar KOEL Norms with requisite basic computerised initial inputs programmed to run the DG set on Auto/Manual method all as directed & specified by Engineer-in-Charge.
57M & L replacement of fuel caps with proper lock and key for various DG capacities as per site make & samples all as specified & directed by Engineer-In-Charge.
58Supply of metallic empty barrel (Diesel drum) 210 Ltrs Capacity for DG installations as per sample.
59Excavation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr in depth for laying under ground cable and getting out in hard/dense soil complete all as specified
60Returning filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick all as specified.
61Removal of surplus soil excavated material to a distance not exceeding 50 mtr & deposited where directed at a level not exceeding 1.5 mtr above the starting point all as directed.
62Supply & Laying PCC cable cover LV type 1 250 x 150 x 40 MM size for cable protection flat type ISI marked all as speicfied and as directed by Engineer-in-Charge.
63Sand cushioning to under ground cable with a layer of sand 8 cm deep before laying & 15 cm after laying.
64M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross sectional area 25 Sqmm3.5 core.
65Supply and fixingof moulded case circuit breaker part No:- NSX250F, COMPACT NSX TYPE 3 PHASE 250 AMP, 690 VoltAIC rating – 36 KA @ 415 Vcomplete all as specified
66M & L for sub main wiring with6 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor stranded cable with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC casing & caping of 25 mm dia, medium grade with all conduit accessories/ fittings etc and connected to common earth dolly etc in wall, making good to walls etc including two coats of white/ colour washing/ distempering etc to the disturbed surfaces to match the existing complete all as specified & directed.
67M & L for installation, testing & commissioning of AMF panel indoor type with angle iron pedestal frame cubical type free standing working on 415 Volt 3 phase 50 Hz AC supply complete with colour coated copperbus bars 600 Amp fully compartmentalised dust proof and vermin proff 2 mm thick CRCA sheet enclosure complete including painting and suitable for IP 52 protections as per specifications and having the follwing details :-
68Incomer (i) AMF control circuit with MCCB 4 pole with over load current rating of 400 Amp with ultimate breaking capacity at 415 Volt AC 50 Hz of 36 KA with extended rotary handle with microprocessor release with integral overload setting of 70% to 100% of ultimate breaking capacity complete with all standard accessories all as specified and directed-02 Nos (one for main supply and one for DG set supply) 4 pole changeover contactors AC-3 heavy duty with HRC backup fuse complete with all DC control relays/line voltage monitor (LVM) as per OEM specifications incorporating engine start, stop, three attempt starting facility and failure to start complete. (ii) Circuit diagram plate, (iii) Digital type voltmeter 0-500 V with selector swtich -02 Nos, (iv) Digital ameter 0-300 A with cast resin type Cts and selector swtich -01 Nos, (v) Digital type frequency meter for 50 Hz -01 Nos, (vi) CT operated 3 phase 4 wire 415 Volt 50 Hz KWh meter of accuracy class 1.0 with backlit LCD display for measuring and displaying active energy and flush mounted / BAsic version with Cts ratio 300/5 -5 Amp (complete) -01 Nos,
69OUTGOING FEEDERS:- (i) MCCB 4 pole with over load current rating of 100 Amp with ultimate breaking capacity at 415 Volt AC 50 Hz of 36 KA with extended rotary handle with microprocessor release with integral over load short circuit earth fault and neutral protection with over load setting of 70 % to 100 % and fixed magnetic setting rated service breaking capacity of100% of ultimate breaking capacity complete with all standard accessories all as directed -07 Nos, (ii)MCCB 4 pole with over load current rating of 160 Amp and ultimate breaking capacity at 415 Volt AC 50 Hz of 36 KA with extended rotary handle with microprocessor release with integraloverload short circuit and earth fault and neutral protection with over load settig of 70% to 100%and fixed magnetic setting rated service breaking capacity of 100% of ultimate breaking capacity complete with all standard accessories all as specified & directed -01 Nos, (iii) MCCB4 pole with over load current rating of 125 ampandultimate breaking capacity at 415 Volt AC 50 Hz of 16 KA with thermal magnetic release and with integral overloadshort circuit , earth fault and neutral protection with over load setting of 70 % to 100 % and fixed magnetic setting rated service breaking capacity of100% of ultimate breaking capacity complete with all standard accessories all as directed -01 Nos, (iv) MCB 16 A DP 10 KA -02 Nos, (v) Indication lamps RYB with 3 Nos of 2 A HRC fuses -10 sets, (vi) Bottom gland plate for incoming & outgoing cable.
70M & L installing, testing and commissioning of main panel of 15 Zones for fire alarm system with suitable sounder cards and fault isolaters mounted at security room having facilities of fire indications. The panel wall maounted cabinet shall be made out of 16 SWG CRCA sheets as per is: 2189. The main Control panel should have provision of battery and have the arrangement for audio/Visual indications by duel lamps for fire & faultsin each zone. The panels shall be finished in stove enamel paint of aapproved make, including sealed Nickel- Cadmium maintenance free battery housed in a plastic box with supproting stand & booster /trickle charger, Dc Voltmeter, short circuit ire alarm, push button for lamp test, fire alarm circuits healthy check etc all complete as specified.
71M & L for drawing of 2.5 sq mm single core stranded PVC insulated copper conductor cable conforming to IS: 694 (Part-I) including providing and laying rigid steel conduit in recess/surface including terminations and connections etc complete all as specified and directed by Engineer-in-Charge.
72M & L for installation , testing and commissioning of conventional type optical smoke detector with mounting base suitable for wall/ ceilling mounted, including allconnections etc complete all as specified and directed by Engineer-in-Charge.
73Supply installation and commissioning of factory made fabricated CPRI Approved Indoor type double door complete finished in all respect cubical type LT switch board suitable for and including under mentioned accessories panel shall be fabricated out of 2.00mm thick powder coated mild steel sheet and angle iron frame of 40x40x6mm size and Provn of 4 No’s aluminium bus strip of suitable sizefixed on porcelain insulators and wiring of sections with aluminium strip of suitable size including PCC foundationscomplete in all respect:- (i)MCCB TPN 415 Volt capacity 100 Amps 25KA microprocessor based (ICS100%= ICU) and trip setting as required- 02No ( incoming) (ii) ON load front operated change over switch 415 volt 4 pole of size 100 Amp-01 No. (iii) MCCB TPN 415 Volt capacity 63 Amps 16KA microprocessor based (ICS100%= ICU) and trip setting as required - 02 Nos ( outgoing) (iv) Digital voltmeter 0-500 with selector switch -01 No (v) Digital Amp meter 0-100 with set of CTs and selector switch -01 No (vi) LED indicator lamp (RYB)- 01Set NOTE: - The panel shall be front operated with cable entry from the bottom with cable entry from the bottom with cable glands.
74Taking out servo voltage stabilizer of capacity 300 KVA3 Phase 4 wire AC supply 440 volts for balanced load after disconnecting all electrical connections from main switch, change over switch input/output connection boards etc opening dismantling for pre-inspection and repairing/replacement of worn out parts and testing after re-installation on same foundation.(Parts required forreplacement shall be measured and paid for separately in the relevant items herein after).
75Taking out burnt winding with allied insulating materials of transformer including material and labour for rewinding of main transformer of stabilizer 300 KVA capacity with super enamelled copper winding wire of appropriate gauge and number of turns alongwith insulating materials e.g. leatheriestpaper insulations, cotton tapes etc varnishing with air drying insulation varnish, and heating drying, cleaning of rusts, carbon deposit including transporting to civil workshop and after repair bring it back to its original location as earlier installed etc complete all as directed by Engineer-in-Charge.
76Replacement of dimmer coilof stabilizer of300KVA capacity with super enameledcopper winding wire of appropriate gauge as per existing pattern alongwith insulating material and made the surface for suitable contact with carbon bush complete after removing existing burnt dimmer coil and cleaning complete all as directed by Engineer-in-Charge.
77Supply and replacement of carbon brush with holder for voltage stabilizer 300 KVA capacity 3 Phase for balance load complete.
78Supply and replacement of ampere meter 0-200 Amp 96Sqmm flush type, 3 Phase with selector switch complete including CT’s of suitable sizewith selector switch.
79As per sel item No66 herein before but voltmeter 0-500 volts 96 sq mm with 3 phase selector switch complete.
80Supply and replacement of limit switch to control the Up and down variation of voltage at correct ratio on secondary side complete.
81Supply and replacement of auxiliary (Pulse) transformer heavy duty suitable with the load and voltage variation for low and high voltage variation complete.
82Supply and replacement of indicator lamp of any colour with neon lamp showing the different phases of the stabilizer complete.
83Supply and replacement of push button switch heavy duty of any colour for raising and lowering the voltage manually complete.
84Supply and replacement of sensing control switch to control the voltage variation at upper and lower limit complete.
85Supply and replacement of bakelite electroplated thickness exceeding 10mm provided with desired shape and size drilled holes and fixingof phase terminal complete
86Supply and replacement of brass studs with nuts and washers of different sizes all as required.
87Supply and replacement of copper thimbles suitable for cable of any size and crimped withcrimping tool on termination end of cables.
88Supply and filling of new transformer oil confirming toIS-335 and dielectric strength not less than 60KV.
89Filtration, dehydration of insulating transformer oil to obtain the minimum dielectricstrength not less than 30 KV.
90Supply and replacement of Servo primoverheavy duty of capacity 10 leg/CM2 torque 240 volts step system 60 RPM single phase 50HZ reversible with SDOT switch complete.
91M&L Wiring of measuring instrument on stabilizer with appropriate PVC insulated copper conductor cables and testing on completion.
92Painting to voltage stabilizer with spray painting one coat with synthetic enameled paint of approved colour after making the surface clean by scratching or removing by burning of old paint complete.
93S & Fix of MCCB 3 pole, 415 V, fixed type 400 Amps breaking capacity 36 KA complete all as directed & specified by Engineer-in-Charge.
94S & Fix of MCCB 3 pole, 415 V, fixed type250 Amps breaking capacity 36 KA complete all as directed & specified by Engineer-in-Charge.
95S & Fix of MCCB 3 /4 pole, 415 V, fixed type630 Amps breaking capacity 36 KA complete all as directed & specified by Engineer-in-Charge.
96Dismantling of old burnt APFC panel of any capacity and Supply, install & testing commissioning of APFC panel of capacity 125KVAR with relay 05step auto operation suitable for improving PF upto unity outdoor type made out of 3 mm thick CRCA sheet with channel /angel iron pedestal frame compartmental type dustfree vermin proof IP 52 protection cable alley cable entry hole at the bottom and mounting on PCC (1:3:6) platform raised at 30 CM above ground level with the following accessories (a) Incomer MCCB 4 pole 415 volts with adjustable type 250 Amps with breaking capacity 36KA complete -01 Nos (b) Bus bar aluminium/copper of suitable capacity for phase & neutral -01 set , (c) Capacitor duty contractor of MOC type required capacity -01 Nos (for each capacitor bank) (d) Digital microrocessor based power factor correction replay of 6 step operation suitable for 125 KVAR capacity of APFc panel -01 Nos, (e) 125KVAR capacity bank consisting of 6 steps of operation including of capacitors of voltage 415 Volt long life ultra heavy duty LTXL type 1 X 50KVAR + 2 X 25 KVAR +1 X 15 KVAR + 5 KVAR+5KVARwith suitable MCCB as backup protection. (f) Digital ameter with selector swtich and CTs of suitable capacity, (g) Digital voltmeter with selector swtich of suitable capacity , (h) Internal power & controlwiring with suitable size of PVC insulated copper wire and LED indicating lamps ,incorporating 12 compartmants (01 Compartment as spare) front openingindependantlyof each comparrments complete all as specified & as directed by Engr-in-Charge.
97Weather proof L-T switch copper bus bar panel of 400 Amps in steel box of 3 phase 01 neutral size including making foundation on ground or fixing on wall complete all as specified and directed by Engr-in-charge.
98Taking out oold UNSV burnt AMF relay /controller input Voltage 230 VAC digital display typefrequency 50 HZ automatic, manuaal & semi auto matic complete all as specified and directed by Engr-in-Charge.