Tender For Replacing Of Ac Sheet Roofing With Precoated Gi Profile Sheet Roofing Of Godown G1,G2,G3 , Painting Both Interior And Exterior And Miscellaneous Repairs At Fsd Raichur For The Year 2023-24., raichur-Karnataka

Food Corporation Of India-FCI has published Tender For Replacing Of Ac Sheet Roofing With Precoated Gi Profile Sheet Roofing Of Godown G1,G2,G3 , Painting Both Interior And Exterior And Miscellaneous Repairs At Fsd Raichur For The Year 2023-24.. Submission Date for this Tender is 04-11-2023. Shed Construction Tenders in raichur Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

40316390
Tender For Replacing Of Ac Sheet Roofing With Precoated Gi Profile Sheet Roofing Of Godown G1,G2,G3 , Painting Both Interior And Exterior And Miscellaneous Repairs At Fsd Raichur For The Year 2023-24.
Open Tender
Indian
Karnataka
raichur
04-11-2023

Tender Details

Replacing Of Ac Sheet Roofing With Precoated Gi Profile Sheet Roofing Of Godown G1, G2, G3 , Painting Both Interior And Exterior And Miscellaneous Repairs At Fsd Raichur For The Year 2023-24.

Key Value

Document Fees
Refer document
EMD
INR 250300.0 /-
Tender Value
INR 1.25 Crore /-

BOQ Items

Name of Work:Replacing of AC sheet roofing with precoated GI profile sheet roofing of Godown G1,G2,G3 , painting both interior and exterior and miscellaneous repairs at FSD Raichur for the year 2023-24.
Sl. No. Item Description
1Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar.
2Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of : Asbestos sheet.
3Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking.
4Brick work with burnt clay F P S ( non modular) of bricks class designation 7.5 in superstrcture above plinth level up to floor five level in all shpaes and sizes in cement mortar1:6 (1cement 6coarse sand)
5Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. (Code no. 10.16.1 of DSR 2021)
6Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
712 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand).
8White washing with lime to give an even shade :Old work (two or more coats)
9Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
10Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
11Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work
12Finishing walls with Acrylic Smooth exterior paint of required shade: Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
13Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : one or more coats on old work
14Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
15Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm).
16Providing and fixing turbo/ wind ventilators (extraction capacity of minimum 1800 cubic feet per minute air circulated fan of minimum 22 inches throat dia wind ventilator with FRP base plate) including cost of fixing turbo/ wind ventilators on new 6m thick Asbestos cement corrugated sheet roofing on godown roof including cost & transportation of all materials, tools and plants, fixtures/ fastenings, labour insurance, safety measures, disposal of broken A C sheets as directed by Engineer-in-charge including guarantee for turbo ventilator of minimum 3 years and performance warranty etc. complete.
17Fixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand & manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brand.
18Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of thickness 4 mm.
19Lettering with black japan paint of approved brand and maufacture
20Dismantling rolling shutters including stacking the material within 50 metres lead of :
21Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters 80x1.25 mm M.S. laths with 1.25 mm thick top cover
22Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
23Repairing and Greasing of rolling shutters at the rate of 500 grams yellow cup grease of good quality each shutter after cleaning with Kerosene oil properly including tensioning of springs/ replacement of spring wherever required including replacement of damaged stripes and side koni complete and making easy push & pull operation and removing the top cover and refixing the same after greasing with all materials and labour etc., complete as directed by Engineer-in-charge. (This excludes the cost of spring and strips but including the cost of side koni).
24Deduct for Salvage value of dismantledrolling shuttersas is whereis basis.
25Deduct for Salvage value of dismantled Asbestos sheet as is whereis basis.