}

Tender For Comprehensive Maintenance Of Building Services And Electric Services At Certain Fafa Md Accns At Lichubari Under Ge Jorhat., jorhat-Assam

Military Engineer Services-MES has published Tender For Comprehensive Maintenance Of Building Services And Electric Services At Certain Fafa Md Accns At Lichubari Under Ge Jorhat.. Submission Date for this Tender is 02-11-2023. Building Repair Tenders in jorhat Assam. Bidders can get complete Tender details and download the document.




Tender Notice

40291062
Tender For Comprehensive Maintenance Of Building Services And Electric Services At Certain Fafa Md Accns At Lichubari Under Ge Jorhat.
Open Tender
Indian
Assam
jorhat
02-11-2023

Tender Details

Comprehensive Maintenance Of Building Services And Electric Services At Certain Fafa Md Accns At Lichubari Under Ge Jorhat.

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work:- COMPREHENSIVE MAINTENANCE OF BUILDING SERVICES AND ELECTRIC SERVICES AT CERTAIN FAFA MD ACCNS AT LICHUBARI UNDER
Sl. No. Item Description
1NOTES :The bidders/contractorsare advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
2Dismantling AC roof corrugated sheet, thickness including eves gutter / rain water pipe complete & removal all as specified
3Material, labour and fixed Rolled mild hollow steel sections steel of grade YSt 310conform to IS 4923 in roof trusses (framed), trussed, purlins, bracing and fasteningsincluding distance pieces, cleats etc.complete all as specified and as directed.
4Material, labour and fixed of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed.
5Material, labour and fixed ofpre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridges, tips, valley, gutters, length & girth as fixed with nail or screwscomplete all as specified and as directed.
6Material, labour and fixed of power coatedGI exposed snap grid frame work for false ceiling, size of grid 605 x 605 mm, including GI main tee ofsize 25mm x 35mmx0.7 mm ( minimum), GI cross tree of size 25mmx 35mmx 0.70mm and GI wall angle of size 25mmx25mmx0.7mm(minimum) suspended form soffit at approx 900mm centre to entre with GI cleat and steel expansion fasteners with and including level clip and 6mm diaGI wire hanging arrangement with adjuster all as specified in drawing in section -8 of SSR part-II and including 6 mm thick high pressure steam cured non asbestos fibre cement designerboard as per IS 14862with applying oftwo coats of acrylic distemper over a coat of primer including takingdwon old one complete all as specified and directed.
7Stripping out tarfelt from old roof surfaces and removing unserviceable materials from site of work in low laying in outside MOD area andbrushing and applied neat cement slurry with 3.0 Kg of cement per Square Metre existing surfacecomplete all as specified and as directed.
8Supplying and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt laying over a coat of bituminous primer @ 0.40 Ltr / Sqm and two coats of Bitumen based UV reflective paint with aluminium finish over APP membrane. The membrane shall be laid using butane torch and sealing all joints etc all as specified in Para 11.44.5 of SSR Part Icomplete all as specified and as directed.
9Demolition ofReinforced cement concrete (reinforcement cut as required to facilitate demolition) in any positionand removing debris to a distance n.exc. 50 m etc complete all as specified and as directed.
10Material and labour forTMT Bars Fe 500D 6mm dia& 8 mm dia cut to length bent to shape required inculding cranking bending spirally hooping for columns etc and binding with MS wire ennealed less than 0.9mm dia or securing with clip complete all as specified and directed.
11Demolition of cement concrete (un-reinforced) in ground floors, sunken floor and paving complete all as specified
12Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to stores and rubbish off the MOD premises complete all as specified and as directed.
13Material and labour for 75 mm thick plain cement concrete M-10(Nominal Mix) using 20 mm graded stone aggregate as in plinth protection, finished even and smoothwithout using extra cement complete all as specified and as directed.
14Material and labour for 40 mm thick plain cement concrete 15 (Nominal Mix) using20 mm graded stone aggregateaggregate as inbase floor finishing cement concrete surfacesroughetc complete all as specified and directed
15Material & Labour Non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular area of each tileexceeding 0.06 Sqm and not exceeding 0.11 Sqm , in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bedlayer in CM (1:4) including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushign neat cement slurry with 3.0kg of cement per Sqm complete all as specified and as directed.
16All as per item no but as in skirting/dado but over 10 mm thick rendering over CM 1:4
17Material & Labour Glazed ceramic tiles 450x300/ 300x200 x7 mm(Coloured)on vertical surfaces such as skirting, dados and riser to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match complete over 10mm thick screed bed vertical layer in CM (1:4)all as specified and as directed.
18Material and labour forpre-polished chequered Cement Concrete tiles of25 mm minimum thick, size of(square/ rectangular) area of each tile exceeding 0.09 Sqm but not exceeding 0.16 Sqm double layer machine pressed set ( as per IS 1237-2012), jointed and pointed in neat cement slurry in floors and cut & polished in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specifiedandas directed.
19Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
20Cutting holes in brick walls exceeding half brick but not exceeding one brick built in cement mortar for inserting hold fasts of GI pipe and making good dismantled portion in cement concrete 1:2:4 type B1 exceeding one brick.
21Material and labour for Brick work with bricks class designation 75, old size, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
22Material and labour forbrick work with bricks class designation 75,size as per old size brick, straight or curved on plan exceeding 6 m mean radius half brick thick walls built in Cement Mortar 1:4 complete all as specified and as directed.
23Taking down cement plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and removaloutside of MOD land complete all as specified and as directed.
24Rendering 15 mm in Cement Mortar 1:6 on fair faces of brick work or concrete surfaces finished even smooth withoutusing extra cement to the plastered surfacecomplete all as specified and as directed.
25Material and labour for Rendering 15mm thick plaster in Cement Mortar (1:4) on fair faces of brick or concrete surface of wall and finishedeven and smooth withoutusing extra cement, with water proofing treatment. Note:- Water proofing compound shall be measure and paidseparately
26Material and labour for Rendering 5mm thick plaster in Cement Mortar (1:3) on fair faces ofconcrete surface on ceiling and finishedeven and smooth withusing extra cement, with water proofing treatment.
27Supply only integral liquidwater proofing compound
28Material and labour for Preparation of new plaster wall surface and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litreof required colour shade and as per manufacturer’s specification over a coat of primer over a coat of 1.0 mm thick cement base wall putty complete all as specified and directed.
29Material and labour for Preparation of new plaster ceiling surface and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litreof required colour shade and as per manufacturer’s specification over a coat of primer over a coat of 1.0 mm thick cement base wall putty complete all as specified and directed.
30Material and labour for completeremoval of existing finishing of internal wall surface of building/structure by mechanical appliance and preparation ofold surfaces and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litreof required colour shade and as per manufacturer’s specification over a coat of primer over a coat of primer over a coat of 1.0 mm thick cement base wall putty complete all as specified and directed.
31Material and labour for preparation of old internal wall surface of building/structureand preparation ofold surfaces and applying one coats of acrylic washable distempercomplete all as specified and directed.
32Material and labour forpreparation of new surfaces andand applying 2 coats of cement based paint over a coat of alkali based primer complete all as specified and directed.
33Material and labour for Preparation of old external wall surfaceand applying one coat of cement based paint of any description over 10 cm girth or widthcomplete all as specified and directed.
34Taking down chowkats/frames with shutters (without taking off shutters from the frame) etc. exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and as directed.
35Taking down chowkats/frames with shutters (without taking off shutters from the frame) etc.exceeding 1.0 Sqm but not exceeding 1.50 Sqm each complete all as specified and as directed.
36Taking down shutters of any description n exc 1 sq. meachcomplete all as specified and directed.
37Mild steel work as in bands, straps, supports or stays for RWP, ventilating pipes, clamps, hold fasts, wall ties conforming to Fe-290 Gde E-165
38Supply and fixing of2nd class HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixedcomplete all as specified and directed.
39Material and labour for PCC 1:2:4 type B-1 using 20mm graded crushed aggregate as infilling in holdfast/ filling in pressed steel frame etc including necessary form work complete all as specified and directed.
40Material and labour for 30 mm thick, second class hard wood, factory made glazed and skeletonshutters, open rebated and prepared to receivegauze, etc.with plain chamfered or rounded, mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed.
41Supply and fixing of 30 mm thick flush shutters, solid core construction, with block board core and comercialplywood face panels with one face is covered with decorative face veneer with lipping/frame to match all complete all as specified and as directed.
42Material and labour for Solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with Mild Steel square tube, suppling & fixing in opening as per drawing complete all as specified and directed.
43Material and labour for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawingcomplete all as specified and directed.
44Supply and fixing of steel ventilator with top hung shutters including hingeswith steel handle and steel peg stay complete without gauged bars, dovetailed or weldedcomplete all as specified and as directed
45Supply and fixing of steel windows with side hung shutters including hinges projecting type with steel handle and steel peg stay complete with gauged bars, dovetailed or weldedcomplete all as specified and as directed
46Supply and fixing of steel windows with side hung shutters including hinges box type with steel handle and steel peg stay complete without gauged bars, dovetailed or weldedcomplete all as specified and as directed
47Material and labour forMild Steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe-290(Gde E-165) complete all as specified and directed.
48Supply and fixingof sheet glass 4 mm thick ordinary quality fixed to aluminum door & window in squares in each pane of required size complete all as specified and as directed.
49Supply and fixing of Butt hinges Stainless steel100 mm size complete all as specified and directed.
50Supply and fixing of Aluminium anodised barrel tower bolts of extruded section size 150 mm complete all as specified and directed.
51Supply and fixing of Aluminium anodised barrel tower bolts of extruded section size 200 mm complete all as specified and directed.
52Supply and fixing of Aluminium handles cast type anodised 150 mm size complete all as specified and directed.
53Supply and fixing of Aluminium handles cast type anodised 125 mm size complete all as specified and directed.
54Supply and fixing in repairs Stainless Steel drapery road (1 mm thick stainless) steel section outer dia 25 mm with bracket, ring & fancyside holders complete all as directed by Engr-in-Charge
55Supply and fixing in repairs ofHasp and staple, safety type, Stainless Steel with Stainless Steel hinge pin including bolt to hinge plate and fixed with screws of size 100 mm.
56Supply and fixing of 300mm ordinary rat tail rod pattern springs including roller and roller plate complete made out of brasscomplete all as specified and as directed
57Supply and fixing in repairs of small fitting of second class HW such as brackets of any type latch and hinge block, shaped door and window stops and the like incl all necessary labour articles not exceeding 200 Cu cm each. complete all as specified and directed.
58Supply and fixing of Stainless steel wire cloth, 0.36mm nominal dia of wire and avergae width of aperture 1.00 mm and fixed with stainless steel wire staples complete all as specified and directed.
59Supply and fixing in repairsStainless steel wire cloth, 0.36 mm nominal dia of wire and avergae width of aperture 1.00 mm and fixed with stainless steel wire staples complete all as specified and directed.
60Material and labour for 18/19 mm thick prelaminated particle board exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work including taking dwon old one complete all as specified and directed.
61Material and labour for preparation of new steelsurface and applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel and iron surfaces of any description over exceeding 10 cm in width or girthcomplete all as specified and as directed..
62Material and labour for Painting 2 coats of synthetic enamel paint on wooden surfaces of any description over 10 cm in width or girth including preparation new surface and one coat of pink primercomplete all as specified and as directed.
63Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
64Supply and fixing of 15mm bore galvanised steel tubes, medium grade with all fitting and fixed to walls, ceiling, floors and including taking up old GI pipe complete all as specified and as directed.
65Supply and fixing of 20mm bore galvanised steel tubes, medium grade with all fitting and fixed to walls, ceiling, floors and including taking up old GI pipe complete all as specified and as directed.
66Supply and fixing in repair of bib cock cast copper alloy screwed down with long body with wall flange,and fixed for 15 mm bore GI tube pipe and all accessoriescomplete all as specified and as directed. complete all as specified. Make :- Cat no 272210120031(DHAARA) of Somany or equivalent model of make list as given in PS as approved by GE.
67Supply and fixing in repair of chromium plated pillar cock cast copper alloy screwed down with long body with wall flange,and fixed for 15 mm bore GI tube pipe and all accessoriescomplete all as specified and as directed. complete all as specified. Make :- Cat no272210120011(DHAARA) of Somany or equivalent model of make list as given in PS as approved by GE.
68Supply and fixin ofin repair 15 mm bore chromium plated stop valve with crutch handle ,fancy type , screwed both ends for iron pipes etccomplete all as specified and directed. Make :- Cat no272210120071(DHAARA) of Somany or equivalent model of make list as given in PS as approved by GE.
69Supply and fixing of 15mm bore angle valve type cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe for union 15mm complete all as specified and directed.
70Supply and fixing in repair of Bib tap standard of PTMT any colour high pressure screwed for 15 mm bore diairon pipe and fixed .(Minimum weight 15mm-90gms)complete all as specified.
71Supply and fixing in repair of pillar traps standard of PTMT any colour high pressure screwed for 15 mm bore diairon pipe and fixed .(Minimum weight 15mm-90gms)complete all as specified.
72Supply and fixing in repair of stop angle valve standard of PTMT any colour high pressure screwed for 15 mm bore diairon pipe and fixed .(Minimum weight 15mm-90gms)complete all as specified.
73Supply and fixingof vitreous china wash basin white flat back, size 550 x 400 mm includingCP waste coupling,with GI pipe brackets & , rag bolt in cement concrete/brick wall and including taking down existing HWB and making good wall surface complete all as specified and as directed.
74Supply and fixing ofVitreous china squatting pan, "Orissa" pattern, size 580x440 mm white with includingCI ‘P’ or ‘S’ trap & integral foot rests fixed in cement concrete and including taking down existing one complete all as specified and as directed
75Supply and fixing ofVitreous china wash down water closet (pedestal pattern) with concealed S-trap or P-Trap, white, 390 mm high, seatcoverincluding connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etcand including taking down existing one complete all as specified and as directed
76Supply and fixing as in repair of PVC low level flusing cistern 10 litres capacity white with ball valve & brackets with flush pipe complete all as specified and as directed.
77Supply and fixing as in repair of PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
78Supply and fixing in repair of 125 mm dia of shower rosewith 225 mm long arms, cast copper alloy chromium plated ,swivel jointsand fixed for 15 mm bore GI tube pipe and all accessoriescomplete all as specified and as directed. complete all as specified.
79Material and labour for 600 x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood complete all as specified and as directe
80Supplying, hoistedand fixedin position of rotational moulded polyethylene water storage tanks in doublelayers and cylindrical vertical type with manhole lids(closed top) of 500 litres capacity with ISI marked and all as specified in IS 12701 and including taking down existing water tank complete all as specified and directed .
81Supply and fixingofPVC ball valve for 20 mm dia GI pipe all completecomplete all as specified and directed.
82Supply and fixing of uPVC oftype-B for use in soil and waste discharge systems, single socket, 110 mm bore in any length including rubber ring joints and fixed to walls with clips and other standard materialand including taking dwon oldrain water pipe & removal from siteall as specified in IS 13592complete all as specified and directed.
83Supply and fixing of uPVC oftype-B for use in soil and waste discharge systems, single socket, 75 mm bore in any length including rubber ring joints and fixed to walls with clips and other standard materialand including taking dwon oldrain water pipe & removal from siteall as specified in IS 13592complete all as specified and directed.
84Supply and fixing of Unplasticized (uPVC )bendfor 110 mm bore uPVC pipe complete all as specified and directed.
85Supply and fixing of Unplasticized (uPVC )bendfor 75 mm bore uPVC pipe complete all as specified and directed.
86Supply and fixing of Unplasticized (uPVC )juction equal or unequalfor 110 mm bore uPVC pipe complete all as specified and directed.
87Material and labour for PVC(SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directe
88Material and labour for PVC(SWR) nahani trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directe
89Supply and fixing ofin repair uPVC (SWR) mutitrap 75 mm, plain with CP grating including joining and solvent cement complete all as specified and directed.
90Supply and fixing ofin repair uPVC (SWR) floortrap 75 mm, plain with CP grating including joining and solvent cement complete all as specified and directed.
91Supply and fixin ofin repair 32 mm dia waste coupling suitable for kitchen sink waste pipe etccomplete all as specified and as directed by Engineer-in-Charge .
92Supply and fixing as in repair ofhealth faucet of ABS body with wall hook and including one metre longstainless steelbraided rubber hose pipe fixedon 15 nn dia angle cockall completecomplete all as specified and directed Make:-Cat No. BEA-41 Prayag equivalent model of make list as given in Approved Make list .
93Plain Cement Concrete M-10(Nominal Mix) using 12.5 mm graded stone aggregate as inmaking goodwindow opening, lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, coping, kneelers, apex stones, bed plates, kerbs, water trough and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and directed.
94Material and labour for Plain Cement Concrete M-15(Nominal Mix) using 20 mm gaded stone aggregate as in Surface channel and drain
95Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.
96Cutting into existing manhole for connecting new drain, making good to pipe & rendering, cutting out existing benching for and forming branch channel (half round or 3/4 section) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate for 100 mm bore pipe complete all as specified and directed.
97Cutting into existing manhole for connecting new drain, making good to pipe & rendering, cutting out existing benching for and forming branch channel (half round or 3/4 section) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate for 150 mm bore pipe complete all as specified and directed.
98Supply,layingand testing ofPVC(SWR) pipe of 100 mm dia with ISI marked(with CML no) with and including all fitting & jointing materialfor sewage line and laid in trenches as specified in IS-16098-2013 part-2 complete allas specified and as directed. .
99Material & Labourfor for cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes 100 mm bore, including packing under and hunching against the sides of pipes after they are laid and tested complete all as specified and as directed. Note:- Thickness of PCC bed 10 cm and width of PCC bed shall be outer dia of pipe plus 30 cm.
100Removing all deposited material i.e. mud, solids, brickbats, polythene silt etc from surface drainof any girth and cleaningof surface area of drain by wire brush completes as and specified and directed.
101Material, T&P and labour for Cleaning of sewage line of any dia/bore including manhole using the cleaning devices and removing blockage if any and removing the waste outside MD land etc complete all as specified and as directed.
102Material, T&P and labour for Cleaning of blockage of wash basin, floor trap, nahani trap, gully trap (GT), kitchen, bath etc. (carrying sludge) in any length upto the first manhole by any means (using chemical or any mechanical device) & flushing with water complete all as specified and as directed.
103Material, T&P and labour for Cleaning of blockage of WC/Urinal (carrying soil waste) in any length upto the first manhole using the cleaning devices and removing blockage if any complete all as specified and as directed.
104Material and labourfor cleaning ofPVC tank of capacity exceeding 750 ltrand not exceeding 1000 ltr with fibre brush to remove all dirts and removing sediments and through cleaning of rotational moulded polythene water storage tank and then with dilute bleaching powder solution(not less than 1.2 Kg per tank) and and finally cleaning with fresh water complete all as directed.
105Material and labourfor cleaning ofPVC tank of capacity exceeding 250 ltrand not exceeding 500 ltr with fibre brush to remove all dirts and removing sediments and through cleaning of rotational moulded polythene water storage tank and then with dilute bleaching powder solution(not less than 0.75Kg per tank) and and finally cleaning with fresh water complete all as directed.
106Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out as in soft/loose soil.
107Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level n. exc. 1.50 m above the starting point.
108Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil.
109Material and labour for Plain Cement Concrete M-7.5(Nominal Mix) using 40 mm graded stone aggregate as in foundation filling and mass concretecomplete all as specified and directed.
110Supply and fixing in repair of stainless steeel of 304 grade ofkitchen sink with drain board of overall size 915mmx460mm and bowl size 410mm x330mmx160mm depth or equivalent made of 1mm thick stainless steel sheet with 32mm bore CP waste coupling including ball and chain 300mm long with bass cap rubber plug, 32mm bore PVC waste pipe (heavy duty) 90cm long, and bedded in cement mortar and fixed in CP cantilever brackets. Make: Cat No. 1239D of PRAYAG or equivalent make as per PS
111Material and labour for Plain Cement Concrete M-15(Nominal Mix) using 20 mm graded stone aggregate in roof kerbs or mud stops, benching,rounded or chamfered on edges including necessary formwork. complete all as specified and as directed.
112Material and labour for Precast Reinforced Cement Concete cover slab type M-20 (Nominal mix) using 20 mm graded stone aggregate, set in Cement Mortar (1:4) complete all as specified and directed.
113Material and labour for cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes 150 mm bore, including packing under and hunching against the sides of pipes after they are laid and tested complete all as specified and as directed. Note:- Thickness of PCC bed 10 cm and width of PCC bed shall be outer dia of pipe plus 30 cm.
114Up rooting of tree from walls/ roof surface of bldgs up to extranded root and spraying of Muratic Acid required quantity complete from any location of bldg and making good disturbed surface with cement mortar(1:4) or cement concrete type C1 (1:3:6) using 20mm graded aggregatecomplete all as specified and directed.
115Subtotal of Sch A part-I
116SCHEDULE "A" PART - II FOR E/M PORTION (Sl No __ to ____)
117Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and switch boxes etc complete and making good the disturbed surfaces complete all as specified and as directed.
118Material and labourfor point wiring with PVC insulated unsheated stranded copper conductor cable of size 1.5 sq mm in and including PVC cassing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan/bell controlled by one switch complete all as specified and directed .
119Material and labourfor point wiring with PVC insulated unsheated stranded copper conductor cable of size 1.5 sq mm in and including PVC cassing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly one 3 pin socket outlet 5 amps on the same board with other switchescomplete all as specified and directed .
120Material and labourfor point wiring with PVC insulated unsheated stranded copper conductor cable of size 1.5 sq mm in and including PVC cassing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly forone 5 amp socket independent complete all as specified and directed .
121Material and labourfor point wiring with PVC insulated unsheated stranded copper conductor cable of size 4.0 sq mm in and including PVC cassing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 4.0 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly forone 5 amp socket independent complete all as specified and directed .
122Supply and fixing of switch piano flush single pole one way 5 ampscomplete all as specified and as directed.
123Supply and fixing of switch socket outlet 3 pin 6 Amps 230 volts Universal typecomplete all as specified and as directed.
124Supply and fixing of switch piano flush single pole one way 15 ampscomplete all as specified and as directed.
125Supply and fixing of socket outlet 3 pin 6/15 Amps 230 volts Universal typecomplete all as specified and as directed.
126Material and labour for Electronic type fan regulator step type 120 watt, 230 volt completeall as specified andas directed. Make : Code no 14502 of Anchoror equivalent model of make list as given in PS as approved by GE.
127Supply and fixingceiling rose surface bakelite 65x50mm three terminalscomplete all as specified and as directed.
128Supply and fixingin repair of LED surface/ceiling mounting(suspended fromceiling) box type light fitting20Watt with LED Lamp , drive and made of epoxy powder coated extruded aluminium channel housing with high quality polycarbonate opal diffuser cover& highpower LED’s as light sourcewith 120Lumen perwatt (Minimum) andincluding all other standard accessories as per manufacture instructions ,internally pre-wired including connecting upthree core1.00sq. mm copper conductor flexible wire/cable complete all as specified. Make : Model No CCS-100-20-65-HL2-DP-NWH ofCrompton/ BCLAB 20W WH LED P of Bajaj or equivalent model of make list as given in PS as approved by GE.
129Supply and fixingofsheet metal enclosure for MCBs to be used singal pole & nutral double door 8 Way 200 Amps rated busbarand including fixed with 25mm x 6 mm mild steel clamp of suitable length complete all as specified and as directed.
130Supply and fixingof MCB SP of rating 6 to 32 Amps 240 V complete all as specified and as directed.
131Supply and fixing MCB DP 40 to 63 amps 415 volts 10KA breaking capacitycomplete all as specified and as directed.
132Supply and fixingof sub main wiring with two single core 4.0sqmm (nominal area) PVC insulated copper conductorFRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC double lock casing caping andaccessoriesaccessoriesincluding one single core 4.0 sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed. NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length.
133Taking down ceiling fans of 1200 mm sweep and any size including cable connectionsand disconnecting of fan bladesand removing the fan with blades to store yard and hanging ceiling fan in its original positionor any other position including as per direction of Engineer-in-Charge includingfitting and fixtures after carrying out the repairs i.e cleaning, greasing and filling, painting of fan with one coat of synthetic enamel paint by spraying machine after preparation of surface by cleaning all dust and filling cavity with filler, reassembling the fan etc including testing complete all as specified and directed by Engr-in-charge.
134Taking down of225 mm Sweep exhaust fan and any size including cable connectionsand disconnecting of fan bladesand removing the fan with blades to store yard and hanging ceiling fan in its original positionor any other position including as per direction of Engineer-in-Charge includingfitting and fixtures after carrying out the repairs i.e cleaning, greasing and filling, painting of fan with one coat of synthetic enamel paint by spraying machine after preparation of surface by cleaning all dust and filling cavity with filler, reassembling the fan etc including testing complete all as specified and directed by Engr-in-charge. Note for item no 133 to 134 :- Contractor"s quoted rates shall including the following (i) Taking down fan and refixing in the same position and or any other position complete with its all fittings and fixtures to make it complete functional and testing complete. (ii) All spare part (except spare partmentioned in here-in-below) repairs including greasing, oiling, prepartion of surface including filling to receiving a coat of paint (iii) Painting ofMES number (only) with black paint
135Material and labourfor rewinding of burnt fan motor with super enameled copper wire suitable for ceiling fan of sweep up to 1200 mm complete all as specified and as directed by Engr-in-Charge.
136All as per item No-58above but for 225 mm Sweep exhaust fan complete all as specified and as directed.
137Supply only fan capacitor 2.5 MFD after complete all as specified and directed. MAKE : Bajaj / Universal / Usha.
138Supply only fan capacitor 3.15 MFD after complete all as specified and directed. MAKE : Bajaj / Universal / Usha.
139Material and labourfor comprehensive repair/ maintenance of storage type electric water heater (geyser) vertical or horizontal type of capacity 25/50 ltrs comprising of the following :- (a) Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank upto the satisfaction of the Engr-in-Charge. (b) Checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc in situ to ensure free movement of the parts including supply and replacing then washers/ gasket nut etc. (c) Checking and rectifying earth continuity of the electrical circuits of the geyser and power point. (d) Checking and refixing thermostat and re-adjust (e) De-scaling the immersion type heating element and siphon assembly with diluted hydro chloric acid or clear pedette solution. (f) Checking of indicator lamp for its serviceability (g) Re-assembling the Geyser, re-install and testing complete. Note:- Contractor"s quoted rates shall including the following (i) Taking down fan and refixing in the same position and or any other position complete with its all fittings and fixtures to make it complete functional and testing complete. (ii) Parts/ components of geysers found unserviceable shall be replaced by the contractor with new parts/ components and same shall be measured and paid separately(except spare partmentioned in here-in-below) and other minors parts shall be deem to be quoted rate.
140Supply only Heating element 2000 Watt complete all as specified and directed.
141Supply only Heating element 1500 Watt complete all as specified and directed.
142Supply only Thermostat for geyser suitable to work up to 80" C complete all as specified and directed.
143Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level,connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised ironusing GI 4 mm dia wire as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit inPCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layercomplete all as specified and directed .
144Note: Schedule of credit (SCHEDULE OF CREDIT)amount of Rs ?___________mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail