Tender For Construction Of New Community Hall Ward No.2 Anna Nagarin Peraiyur Town Panchayat., peraiyur-Tamil Nadu

Town Panchayats-TP has published Tender For Construction Of New Community Hall Ward No.2 Anna Nagarin Peraiyur Town Panchayat.. Submission Date for this Tender is 20-10-2023. Building Work Tenders in peraiyur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

40283663
Tender For Construction Of New Community Hall Ward No.2 Anna Nagarin Peraiyur Town Panchayat.
Open Tender
Indian
Tamil Nadu
peraiyur
20-10-2023

Tender Details

Tender For Construction Of New Community Hall Ward No.2 Anna Nagarin Peraiyur Town Panchayat. ; 1 Earth Work Excavation For Foundation In All Soils And Sub-Soils And To Full Depth As May Be Directed Except In Rock Requiring Blasting Inclusive Of Shoring Shuttering, Bailing Out Water Wherever Necessary And Depositing The Surplus Earth Within The Compound In Places Shown By Thedepartmental Officers With An Initial Lead Of 10 Mts And Initial Lift Of 2 Mts. And Clearing And Levelling The Site, Etc., Complete Complying With Standard Specification. 2 Cement Concrete 1:4:8 ( One Cement, Four Sand And Eight Hard Broken Stone Jelly ) Using 40 Mm Gauge Hard Broken Granite Stone Jelly For Foundationincluding Dewatering Wherever Necessary And Laid In Layers Of Not More Than 15 Cm Thick Well Rammed, Consolidated And Curing Etc. Complete Complying With Standard Specification 3 Collection Supply And Filling Of Well Gravel Filling Approved Quarry Including Cost Andconveyance Of All Materials To Site And All Labour Charges For Filling Etc., Complete. 4 Brick Masonary In Cement Mortar 1:5 Mix ( One Part Of Cement & Five Parts Of Sand ) Usingbest Qualitybricks Of Size8-3 / 4 X 4-1 / 4 X 2-3 / 4 Including Cost And Conveyance Of All Materials To Work Site And Including All Labour Charges For Mixing, Laying, Curing The Concrete Etc., Complete As Per Standard Specifications And As Directed By Departmental Engineers – Tnbp No:31Foundation And Basement 5 Ground Floor 6 Supplying And Erecting Centering For Sides And Soffits Including Supports And Strutting Uptp 3.29M Height For Plane Surfaces In All Floors With All Cross Bracings Using Mild Steel Sheets Of Size 90Cmx60cm And 10 Gauge Stiffened, Welded With Mild Steel Angles Of Size 25Mmx25x3mm For Boarding Laid Over Silver Oak ( Country Wood ) Joist Of Size 10Cmx6.5Cm Dia Spaced About 90Cm Centre To Centre And Supported By Casuarina Props Of 10Cm To 13Cm Dia Spaced At 75Cm Centre Tocentre Etc.Complete Complying With Standard Specification And As Directed By The Departmental Engineers. Tnbp No.30Grade Beam And Footing 7 Plane Surfaces Such As Rcc Slabs, Lintel, Beam, Waist Slab Etc., 8 Plane Surfaces For Squarecolumn 9 Reinforced Cement Concrete 1:1.5 :3 ( One Cement, One And Half Sand And Three Hard Broken Stone Jelly ) Using 20 Mm Gauge Hard Broken Granite Stone Jelly For All Rcc Items Of Works Excluding Cost Of Reinforcement Grill And Fabricating Charges Centering And Shuttering But Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc. And Providing Fixtures Like Fan Clamps In The Rcc Floor / Roof Slabsetc., Complete Complying With Standard Specification And As Directed By The Departmental Officers Foundation Basement 10 Ground Floor 11 Supplying, Fabricating And Placing In Position Mild Steel / Ribbed Tor Steel Grills For All Rcc Works As Per Design Given Including Cost Of Steel And G.I. Binding Wire In All Floors Etc. Complete Complying With Standard Specification. ( Contractor Has To Make His Own Arrangements For The Supply Of Steel And Binding Wire ) 12 Granolythic Floor Finishing With Cement Concrete 1:2:4 ( One Part Of Cement , Two Part Of Sand And Four Parts Of Hbg Jelly ) Mix Using 10Mm To 12Mm Iss Size Hbg Metal To 25Mm Thick Including Cost And Conveyance Of All Materials Etc. And All Labour Charges Etc. Complete As Per Standard Specification And As Directed By The Departmental Officers Tnbp No. 39 F 13 Flooring With Following Ceramic Tiles Of Size 305 X 305 X 6 Mm Laid Over 20 Mm Thick Cement Mortar 1:3 ( One Cement And Three Sand ) Base Mortar Over The Existing Slab / Floor Including Cutting The Tiles To The Required Size With Special Cutter Wherever Necessary, Laying In Position And Pointing With White Cement Mixed With Colouring Pigment At The Rate Of 0.3 Kg. / Sq.M. Etc., Complete Complying With Standard Specification. ( The Make And Brand Of The Tiles Should Be Got Approved By Executive Engineer Before Use On Works ) 14 Daddoing With First Quality Colour Glazed Tiles Of 150 Mm X 150 Mm X 6Mm Size Of Approved Make And Quality And Colour Set In Cement Mortar 1:2 ( One Cement And Two Sand ) And Pointing With White Cement Neatly Including Cost And Conveyance Of All Materials Etc.And All Lobour Charges Etc.Complete As Per Standard Specification And As Directed By The Departmental Officers.Tnbp No:Special 15 Weathering Course Concrete Using Best Quality Broken Brick Jelly Of Size 20Mm Uniform Gauge In Pure Slaked Lime ( No Sand To Be Used ) Over The Rcc Roof Slab In The Propotion Of Brick Jelly To Lime Being 32:121 / 2 By Volume And Laid Over In A Single Layer And Consolidated To The Required Design And Finished Thickness , Beating The Concrete With Wooden Beaters Of Approved Pattern, Keeping The Surface Constantly Wetted By Sprinkling Lime Jaggery Water As Per Standard Specification, Etc.Complete As Directed By The Departmental Officers.Tnbp No:44-I 16 Finishing With Top Of Roof With One Course Of Machine Pressed Tiles Of Size 20Cmx20cmx2cm Of Approved Quality Laid In Cement Mortar 1:3 ( One Cement And Three Sand ) 12Mm Thick Mixed With Water Proofing Compound Conforming To Iss By 2% Weight Of Cement Used And The Joint Pointed Neatly To Full Depth Of Tiles With Same Water Proofing Compound Mixed With Cement Motar , Red Oxide, Etc.Complete Complying With Standard Specification As Directed By The Departmental Officers.- 10 M2tnbp No:44-I 17 Plastering With Cm 1:5 ( One Part Of Cement & Five Parts Of Sand ) Mix For 12Mm Thick Including Cost And Conveyance Of All Materialsto Work Site And Including All Labour Charges For Mixing, Laying, Curing, Finishing Etc., Complete As Per Standard Specifications And As Directed By Departmental Engineers – Tnbp No:56&57 18 Special Ceiling Plastering With Cm 1:3 ( One Part Of Cement & Three Parts Of Sand ) Mix For 10Mm Thick Including Cost And Conveyance Of Materials To Work Site And Including All Labour Charges For Mixing, Laying, Curing, Finishing Etc., Complete As Per Standard Specifications And As Directed By Departmental Engineers – Tnbp No:30, 56&57 19 Supplying , Fabricating And Fixing In Position Of Aluminium Anodized Natural Colour Matt Finish With Half Prelaminated Particle Board And Half Glazed Door Using 5.50M Thick Plain Glass .The Door Frameshall Be Anodised Ajuminium Box Section Of Size 101.6X44.45X3.18Mm At 2.319 Kg / M. The Shutter Frame Shall Be Of Aluminium Anodised Box Type Section Of Size 50X 44.45X 2.5Mm @ 1.202 Kg / M For Vertical Styles And Top Rails. The Lock Rails Shall Be Using Box Type Section Of Size 50X 44.45X 2.5Mm @ 1.292 Kg / M And Bottom Rail Shall Bebox Type Section 100.40X 44.45X 2.5Mm @ 1.974 Kg / M. The Rate Shall Include The Provision For Necessary Accessories Such As Pivot - 1No. Aluminium Clips, Rubber Beading , Pvc Felt, Locking Arrangements, Furniture Fittings Such As Aluminium Tower Bolts - 250X12mm - 1No., Aluminium Tower Bolt 200X12mm - 1No Aluminium Door Stopper With Rubber Bush - 1No., 200Mm Long D Type Handle For Both Sides -2No., Lock - 1No., Hydraulic Door Closer Of Approved Quality Using Aluminium Extruded Section Body Tubular Type With Double Speed Adjustment With Isi Monogram - 1No. Including Cost Of All Materials, Labour Charges And Power Consumption Charges 20 Supplying And Fixing 30Mm Thick Solid Core Pvc Door Shutter With Pvc Frame Of Size 50X45mm With Suitable Rebate For Housing The Shutter ( Confirming To Is 4020 With Updated Amendments ) Consisting Of Frame Made Out Of Ms Tubes 19 Gauge Thickness Etc., Complete 21 Supplying, Fabricating And Fixing In Position Of Aluminiumanodized Natural Colour Matt Finish Sliding Window Arrangements And Shutter Arrangements So As To Drain The Water Entering And Made With Extruded Aluminium Section Of Following Sizes With Necessary Accessories Such As Rubber Beadings, Best Quality Rubber Lock, Handle And Fixing 4Mm Thick Plain / Frosted Glass Including Cost Of All Materials Etc., Complete.Supplyingfabricatingand Fixinginposition Aluminium Sliding Window 22 Fabrication Supply And Fixing In Position Of Aluminium Natural Colour Matt Finish Louvered Ventilator In All Floors Made With Extruded Aluminium Section Of Following Size With Necessary Accessories Such As Rubber Beading, Best Quality Of Handle, Lock Including Supplying And Fixing Of 4 Mm Thick Plain Glass Including Cost Of All Materials, Labour Power Consumption Required For Fabrication Drilling Holes In Rcc Column / Floor Slab / Masonry Wall Wherever Necessary With Power Drills To The Required Extent And Making Good To The Original Condition After Fixing Etc., And As Directed By The Departmental Officers Etc., Complete.The Aluminium Frames To Be Anodised Under Electrically Controlled Condition In Accordance With Isi 1868 / 1962 Specification For An Average Anodic Film Thickness Of Not Less 15Microns And All The Materials Should Be Got Approved By The Executive Engineer Before Use On Work. 23 Supplying And Fixing Of M.S.Grill Of Approved Design For Open Courtyard, Grill, Grill Work To Doors And Window Openings Etc., Using Necessary Mild Steel Flats For Inner And Outer Members Which Should Be Fixed On Edges Including Priming Coat Of Red Oxide Primer Etc., Complete. 24 Supplying And Painting Two Coats Of Newly Plastered Wall Surface With Ready Mixed Exterior Emulsion Paint Of First Class Quality And Of Approved Colour Over A Priming Coat Including Thorough Scrapping, Clean Removal Of Dirt, And Including Necessary Plaster Of Paris Putty, Wherever Required Etc., Complete Complying With Standard Specification. 25 Painting With Two Coats Of Approvedcolour Of Best Quality Synthetic Enamel Paint, Painting Over New Iron Work Including Cost And Conveyance Of All Materials And All Labour Charges Etc. Complete As Per Standard Specification And As Directed By The Departmental Officers. ( New Iron Surface ) .Tnbp No:66&66-A 26 Supplying And Fixing In Position Colour Glazed European Water Closet With P Or S Trap And Double Flapped Seat Cover, 10.00 Litres Capacity P.V.C. Low Level Flushing Tank Including All Internal Fittings Fixed On C.I. Brackets, 12Mm Pvc Or Brass Nipple, Chromium Plated Brown Headed Stopcock, 12Mm Nylon Connection With Necessary Teakwood Plugs, Clamps, Screws To The Portion Coming With Walls And Floors, Including Dismantling Masonry And Redoing The Same To The Original Condition. 27 Wiring With 2X1.5Sqmm ( 22 / 0.3 ) Pvc Insulated Sc Unsheathed Cu.Conductor Of 1100 V Grade In Suitable Pvc Rigid Pipe Concealed In Wall And Ceiling With Pvc Accessories, In Flush With Wall, With 150Mm X 100Mm X 113Mm Twswitch Box With 3 Mm Thick Hylem Sheet Cover For 5 A 3 Pin Non Inter Locking Cs Plug With Continuous Earth Wireconnection Of 14 Swg Tc Wire And Making Good Of The Concealed Portion With Suitable Colour For Concealed Pvcplug Point.Sd 37 28 Supply And Run Of 2X 4 Sqmm ( 22 / 0.3 ) Pvc Insulated Sc Unsheathed Cu.Conductor Of 1100V Grade In 25Mm Dia Gi Pipe ( Class ‘B’ ) Suitably Bent At Bothends With Necessary Angle Iron Upright And End Supports For Mains ( Pwd Standard Data No.Sd. 69 ) . 29 Supply And Run Of 2 Of 4 Sqmm ( 22 / 0.3 ) Pvc Insulated Sc Unsheathed Cu. Conductor Of 1100V Grade On 7 / 20 Gi Bearer Wire For Service Connection Mains. ( Pwd Standard Data No.Sd. 64 ) . 30 Wiring With 2X1.5Sqmm ( 22 / 0.3 ) Pvc Insulated Sc Unsheathed Cu.Conductor Of 1100 V Grade In Suitable Pvc Rigid Pipe Concealed In Wall And Ceiling With Pvc Accessories, With Tw Switch Box 5Aft Switch Flush With Wall 3Mm Thick Hylum Sheet Cover For Making Good Of The Concealed Portion With Suitable Colour For Pvc Cooncealed Light / Fan Point Sd 25 31 Supply And Fixing Of Single Box Type 440 W Fluorescent Fitting Complete With Copper Choke And Condenser Conduit Pipe Suspension Ceilingwith Pvc Unsheathed Copper Lead To Fitting With Tube Sd 88 32 Supplyandfixingoftnebmeterboardsuitablefor32athreephaseserviceconnectionwith3nos.32Afuseunit ( 500V ) 32Aneutrallinkandearthlink ( 1X1 / 8Copperflat ) Ontwplankofsize600mmx450mmx19mmwithsupportingtwreepersof1Thickaneithersidewithpaintingwithsuitableboltandnutsforfixingthetwplankonwallwithearthconnectionandinterconnectionwith7 / 20Pvcinsulatedcopperwirefromebmeter To Fuse Unit Sd 127 33 Supplyandfixingof1200mm ( 48 ) Acceilingfancompletewithsteppedelectronic300wregulatorwith300mm Down Rod On The Existing Clamp Sd 110 34 Supplying And Laying Precast Designer Paver Block Confirming To Is 1568-2006 Specification Manufacturing And Laying Standard Of M50 Grade 83Mm Thick ( Table Clauses 5 And 9.14 ) Suitable For Bus Terminals Industrial Complexes Road On Expensive Soils Etc., Including The Cost Of Paver Block Of Size 225Mm X 12.50 Mm X 80Mm And Conveyance Of Materials To Work Site Mentioned In The Tender Schedule Cost Of Loading And Unloading Handling During Over Sand Bed Of 150Mm Thick ( Excluding The Cost Of Sand ) Conveyance Paver Block Cutter To Site And Hire Charges Of Vibrators And Block Cutter Operator And Labour For Leveling The Sand To Paver Block Etc., Complete Isi 15658-2006.

Key Value

Document Fees
Refer document
EMD
INR 37000.0 /-
Tender Value
INR 37 Lakhs /-

BOQ Items

Name of Work: Construction of NewCommunity Hall Ward No.2 Anna Nagarin PeraiyurTown Panchayat.
Sl. No. Item Description
1Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
2Cement Concrete 1:4:8 (One Cement, Four sand and Eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
3Collection supply and filling of well gravel filling approved quarry including cost andConveyance of all materials to site and all labour charges for filling etc., Complete.
4Brick masonary in Cement Mortar 1:5 mix (One part of cement & five parts of sand) usingbest qualityBricks of size8-3/4" x 4-1/4" x 2-3/4" including cost and conveyance of all materials to work site and including all labour charges for mixing, laying, curing the concrete etc., complete as per standard specifications and as directed by departmental Engineers – TNBP No:31 Foundation and basement
5Ground floor
6Supplying and erecting centering for sides and soffits including supports and strutting uptp 3.29m height for plane surfaces in all floors with all cross bracings using mild steel sheets of size 90cmx60cm and 10 gauge stiffened, welded with mild steel angles of size 25mmx25x3mm for boarding laid over silver oak (country wood) joist of size 10cmx6.5cm dia spaced about 90cm centre to centre and supported by casuarina props of 10cm to 13cm dia spaced at 75cm centre tocentre etc.complete complying with standard specification and as directed by the departmental engineers. TNBP No.30 Grade beam and footing
7Plane Surfaces such as RCC slabs, lintel, beam, waist slab etc.,
8Plane surfaces for squarecolumn
9Reinforced Cement Concrete 1:1.5 :3 (One Cement, one and Half sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabsetc., complete complying with standard specification and as directed by the departmental officers Foundation Basement
10Ground floor
11Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire)
12Granolythic floor finishing with cement concrete 1:2:4 (one part of cement , two part of sand and four parts of HBG jelly) mix using 10mm to 12mm ISS size HBG metal to 25mm thick including cost and conveyance of all materials etc. and all labour charges etc. complete as per standard specification and as directed by the departmental officers TNBP No. 39 F
13Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
14Daddoing with first quality colour glazed tiles of 150 mm x 150 mm x 6mm size of approved make and quality and colour set in Cement Mortar 1:2 (One Cement and Two Sand) and pointing with white cement neatly including cost and conveyance of all materials etc.and all lobour charges etc.complete as per Standard specification and as directed by the departmental officers.TNBP No:special
15Weathering course concrete using best quality broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) over the RCC roof slab in the propotion of brick jelly to lime being 32:121/2 by volume and laid over in a single layer and consolidated to the required design and finished thickness , beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wetted by sprinkling lime jaggery water as per standard specification,etc.complete as directed by the departmental officers.TNBP No:44-I
16Finishing with top of roof with one course of machine pressed tiles of size 20cmx20cmx2cm of approved quality laid in cement mortar 1:3 (One cement and three sand) 12mm thick mixed with water proofing compound conforming to ISS by 2% weight of cement used and the joint pointed neatly to full depth of tiles with same water proofing compound mixed with cement motar ,red oxide, etc.complete complying with standard specification as directed by the departmental officers.- 10 m2TNBP No:44-I
17Plastering with CM 1:5(One part of cement & five parts of sand) mix for 12mm thick including cost and conveyance of all materialsto work site and including all labour charges for mixing, laying, curing,finishing etc., complete as per standard specifications and as directed by departmental Engineers – TNBP No:56&57
18Special Ceiling Plastering with CM 1:3 (One part of cement & three parts of sand)mix for 10mm thick including cost and conveyance of materials to work site and including all labour charges for mixing, laying, curing,finishing etc., complete as per standard specifications and as directed by departmental Engineers – TNBP No:30,56&57
19Supplying , fabricating and fixing in position of aluminium anodized natural colour matt finish with Half prelaminated particle board and Half glazed door using 5.50m thick plain glass .The door frameshall be anodised ajuminium box section of size 101.6x44.45x3.18mm at 2.319 Kg/m. The shutter frame shall be of aluminium anodised box type section of size 50X 44.45X 2.5mm @ 1.202 Kg/m for vertical styles and top rails. The Lock rails shall be using box type section of size 50X 44.45X 2.5mm @ 1.292 Kg/m and bottom rail shall bebox type section 100.40X 44.45X 2.5mm @ 1.974 Kg/m. The rate shall include the provision for necessary accessories such as pivot - 1No. aluminium clips, rubber beading ,PVC felt, locking arrangements, furniture fittings such as aluminium tower bolts - 250X12mm - 1No., aluminium tower bolt 200X12mm - 1No aluminium door stopper with rubber bush - 1No., 200mm long D type handle for both sides -2No., lock - 1No., Hydraulic Door closer of approved quality using aluminium extruded section body tubular type with double speed adjustment with ISI monogram - 1No. including cost of all materials, labour charges and power consumption charges
20Supplying and fixing 30mm thick solid core PVC Door shutter with PVC frame of size 50x45mm with suitable rebate for housing the shutter (Confirming to IS 4020 with updated amendments) consisting of frame made out of MS tubes 19 gauge thickness etc., complete
21Supplying, fabricating and fixing in position of Aluminiumanodized natural colour matt finish Sliding Window arrangements and shutter arrangements so as to drain the water entering and made with extruded aluminium section of following sizes with necessary accessories such as rubber beadings, best quality rubber lock, handle and fixing 4mm thick plain/frosted glass including cost of all materials etc., complete.SupplyingFabricatingand Fixinginposition Aluminium Sliding window
22Fabrication supply and fixing in position of Aluminium natural colour matt finish Louvered Ventilator in all floors made with extruded aluminium section of following size with necessary accessories such as rubber beading, best quality of handle, lock including supplying and fixing of 4 mm thick plain glass including cost of all materials, labour power consumption required for fabrication drilling holes in RCC column / floor slab / masonry wall wherever necessary with power drills to the required extent and making good to the original condition after fixing etc., and as directed by the departmental officers etc., complete.The aluminium frames to be anodised under electrically controlled condition in accordance with ISI 1868 / 1962 specification for an average anodic film thickness of not less 15microns and all the materials should be got approved by the Executive Engineer before use on work.
23Supplying and fixing of M.S.Grill of approved design for open courtyard, grill, grill work to doors and window openings etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of red oxide primer etc., complete.
24Supplying and Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
25Painting with two coats of Approvedcolour of best quality synthetic enamel paint, painting over new iron work including cost and conveyance of all materials and all labour charges etc. complete as per Standard specification and as directed by the departmental officers. (New Iron Surface).TNBP No:66&66-A
26Supplying and fixing in position colour glazed EUROPEAN WATER CLOSET with "P" or "S" trap and double flapped seat cover, 10.00 litres capacity P.V.C. low level FLUSHING TANK including all internal fittings fixed on C.I. brackets, 12mm PVC or brass nipple, chromium plated brown headed stopcock, 12mm nylon connection with necessary teakwood plugs, clamps, screws to the portion coming with walls and floors, including dismantling masonry and redoing the same to the original condition.
27Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TWswitch box with 3 mm thick Hylem sheet cover for 5 A 3 pin non inter locking CS Plug with continuous earth wireconnection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVCplug point.SD 37
28Supply and run of 2x 4 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in 25mm dia GI pipe (Class ‘B’) suitably bent at bothends with necessary angle iron upright and end supports for mains(PWD standard data No.SD. 69).
29Supply and run of 2 of 4 sqmm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade on 7/20 GI bearer wire for service connection mains.(PWD standard data No.SD. 64).
30Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories,With TW switch Box 5AFT Switch Flush with wall 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC cooncealed LIGHT /FAN point SD 25
31Supply and fixing of single box type 4"40 W Fluorescent fitting complete with copper choke and condenser conduit pipe suspension ceilingwith PVC unsheathed copper lead to fitting with tube SD 88
32SupplyandfixingofTNEBmeterboardsuitablefor32Athreephaseserviceconnectionwith3Nos.32Afuseunit(500V)32Aneutrallinkandearthlink(1"x1/8"copperflat)onTWplankofsize600mmx450mmx19mmwithsupportingTWreepersof1"thickaneithersidewithpaintingwithsuitableboltandnutsforfixingtheTWplankonwallwithearthconnectionandinterconnectionwith7/20PVCinsulatedcopperwirefromEBmeter to fuse unit SD 127
33Supplyandfixingof1200mm(48")ACceilingfancompletewithsteppedelectronic300Wregulatorwith300mm down rod on the existing clamp SD 110
34Supplying and laying Precast Designer Paver Block confirming to IS 1568-2006 specification manufacturing and laying standard of M50 grade 83mm thick (table clauses 5 and 9.14) suitable for bus terminals industrial complexes road on expensive soils etc., including the cost of paver block of size 225mm x 12.50 mm x 80mm and conveyance of materials to work site mentioned in the tender schedule cost of loading and unloading handling during over sand bed of 150mm thick (excluding the cost of sand) conveyance paver block cutter to site and hire charges of vibrators and block cutter operator and labour for leveling the sand to paver block etc., complete ISI 15658-2006.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail