Annual Repair And Maintenance Of Various Electrical Installation And Mechanical Equipments At Fire Safety Management Academy, Rohini, Delhi. 2) Rmo Various Electrical Installations And Mechanical Equipment Installed At Various Fire Stations Under Ae(E)-I, Delhi-Delhi

Public Works Department-PWD has published Annual Repair And Maintenance Of Various Electrical Installation And Mechanical Equipments At Fire Safety Management Academy, Rohini, Delhi. 2) Rmo Various Electrical Installations And Mechanical Equipment Installed At Various Fire Stations Under Ae(E)-I. Submission Date for this Tender is 26-10-2023. Fire Alarm Systems Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

40279657
Annual Repair And Maintenance Of Various Electrical Installation And Mechanical Equipments At Fire Safety Management Academy, Rohini, Delhi. 2) Rmo Various Electrical Installations And Mechanical Equipment Installed At Various Fire Stations Under Ae(E)-I
Open Tender
Indian
Delhi
Delhi
26-10-2023

Tender Details

Annual Repair And Maintenance Of Various Electrical Installation And Mechanical Equipments At Fire Safety Management Academy, Rohini, Delhi. 2 ) Rmo Various Electrical Installations And Mechanical Equipment Installed At Various Fire Stations Under Ae ( E ) -I, Nwed, Pwd, Delhi. Dg. 2023-24 ( Sh : Maintenance Of Ei And Fans And Rmo Fire Alarm, Pa System, Drinking Water Supply Pump Sets Of Fsma & Fire Stations Situated At Sector 5 And 16, Rohini. )

Key Value

Document Fees
Refer document
EMD
INR 161769.0 /-
Tender Value
INR 80.88 Lakhs /-

BOQ Items

Name of Work: 1) ARMO various electrical installation and mechanical equipments at Fire Safety management Academy, Rohini, Delhi. 2) RMO various Electrical Installations and Mechanical Equipment installed at various Fire Stations under AE(E)-I, NWED, PWD, Delhi. dg. 2023-24 (SH : Maintenance of EI and Fans and RMO fire alarm, PA System, drinking water supply pump sets of FSMA & Fire stations situated at sector 5 and 16, Rohini.)
Sl. No. Item Description
1(Fire Safety Management Academy, Rohini, Delhi) SUB HEAD - I (Maintenance of EI & Fans) Maintenance and up keeping of all the internal electrical installation and compound lights i/c registration, compliance and monitoring of the complaints in general shift on all days of the month i/c Sundays and Holidays complete as per terms and conditions details of staff & inventory attached - 1 Job Total staff required as per inventory attached is a) Wireman -1 Nos. b) Khallasi - 1 Nos.
2SUB HEAD - II(OPERATION OF DG SET & SUB STATION) Round the clock operation of 11 KV/ 415V Sub-station, one no. 250 KVA DG sets installed at site, on all days of the month including Sundays and Holidays complete as per terms and Conditions, details of staff and inventory attached- 1 Job Total staff required as per inventory attached is a) Wireman cum Operator -3 Nos. (Round the clock) b) Khallasi - 1 Nos.(General shift)
3SUB HEAD - III(OPERATION OF FIRE ALARM SYSTEM, PA SYSTEM, WET RISER SPRINKLER SYSTEM AND WATER SUPPLY PUMPS) Round the Clock running maintenance and operation of wet riser and sprinkler system including filtered/ unfiltered/ sewage pumps installed at site on all days of the month including Sundays and Holidays complete as per terms and conditions, details of staff and inventory attached.- 1 Job Total staff required as per inventory attached is a) Wireman cum Operator -3 Nos. b) Khallasi - 1 nos (General shift)
4SUB HEAD - IV (Operation of Lifts) Operation of 4 Nos. 13 passengers capacity lifts installed at FSMA, Sec-14, Rohini, Delhi on round the clock basis all days of the month i/c Sundays and holidays complete as per terms and conditions, details of staff and inventory attached.- 1 Job. Total staff required as per inventory attached is a) Operator - 4 Nos.
5(Fire Stations under AE(E)-I, NWED, PWD, Delhi.) SUB HEAD - I (Maintenance of EI & Fans) Routine maintenance and attending day to day complaints of electrical installations and compound light / street lights / high mast lights including repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-Charge during breakdown maintenance complete with replacement of worn-out parts issued by the department to the contractor including running maintenance & operation and general upkeep of various capacity drinking water supply pump sets along with sluice/ gate valves etc. and carrying out the daily drill comprising of cleaning of pump house, and maintaining log book for above installation and by deploying multi-tasking staff in 9:00 am to 5:00 pm and Khallasi for each location on all days of the month including Sundays and holidays etc. as required. Total staff required as per inventory attached isa) Wireman -2 Nos. b) Khallasi -2 Nos.(General shift)
6SH-IV Supplying & fixing of following electrical accessories at site as and when required for attending complaints on day to day basis (Labour Cost already included in SH-I) i) 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
7ii) 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
8iii) 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
9iv) 10 sq. mm ISI marked, FRLS PVC insulated, single core copper 4.4 conductor cable
10v) S.P. 5/6 A. one way switch, piano type ISI marked
11vi) 3 pin 5/6 A socket outlet, piano type ISI marked
12vii) S.P. 15/16 A, one way switch, piano type ISI marked
13viii) 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked
14ix) S.P. 5/6 A, one way modular switch, ISI marked
15x) S.P. 15/16 A. one way modular switch, ISI marked
16xi) 6 pin 15/16 A modular socket outlet, ISI marked
17xiii) 6 A to 32 A ratings, SP MCB, "C" curve. 10 kA breaking capacity
18xiii) 6 A to 32 A ratings, DP MCB, "C" curve, 10 kA breaking capacity
19xiv) 40 A Rating, 2 pole RCCB, 30mA
20xv) 6 A to 32 A ratings. TPN MCB. "C" curve. 10 kA breaking capacity
21xvi) 63 A FP MCB "C" curve 10 kA Breaking Capacity
22xvii) 1200 mm Sweep (aluminium body) AC ceiling fan without regulator
23xviii) 2.5 MFD Capacitor
24xix) Piano type electronic fan regulator socket type
25xx) 3 mm thick phenolic laminated sheet
26xxi) Brass batten/ angle holder
27xxii) 20 W LED Batten fitting 4 feet long surface mounted
28xxiii) 300 mm 900/1400 RPM heavy duty exhaust fan ISI Mark
29xxiv) 12 W LED Surface/recess mounted Downlighter
30xxv) 3400 lumen 2 x 2 recessed/surface LED Fittings
31xxvi) 3 x 2.5 sq. mm. pvc insulated PVC sheathed cable
32xxvii) 3 pole MCCB, 400A, 35kA
33xxviii) 3 pole MCCB, 200A, 25kA
34xxix) 3 pole MCCB, 100A, 16kA
35xxx)100 wattLED flood light
36xxxi) 70-72 watt energy efficient LED Street Light
37xxxii) 2 x 25 sq. mm.pvc insulated PVC sheathed cable