| 1 | Dismantlingof plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed |
| 2 | Supply & fixing Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws as specified |
| 3 | Supply & fixing Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws as specified |
| 4 | Supply & fixing 0.63mm thick, galvanised, corrugated mild steel sheeting with two corrugationsside lap, fixed with L-type or J-type or crancked hook bolts and washers as in roofs, walls etc, withgrade of zinc coating 275, complete all as specified and directed |
| 5 | All as per Srl item No. 4.00 here-in-before but except sheet |
| 6 | Supply & fixing 2mm thick fibre glass reinforced translucent corruggated sheeting with two corrugations side lap fixed with L-type or J-type or cranked hook bolts as in roof, wall etc complete all as specified and as directed |
| 7 | All as per Srl item No. 6.00 here-in-before but except sheet |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided forall as specified and as directed by Engr-in-Charge |
| 9 | Supply & fixing Rolled mild steel Gde Fe-290 (gde E-165) asin Roof trusses (framed), trussed, purlins crane gantries, rails & fastenings & heavy brackets framimg (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc. |
| 10 | Demolition of stone slabs and tiles of any description or thickness in floor, aprons etc laid, bedded and pointed in any mortar complete all as specifed and as directed |
| 11 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubish of the premises |
| 12 | Demolition of Cement Concrete (unreinforced) in ground floor and paving n.exc 15cm thickness (below or above ground level) complete all as specified and as directed |
| 13 | M&L PCC 1:3:6 type C1 ( using 20 mm grade aggregate) 75 mm thick as in sub base/plinth protection/pavingcomplete all as specified and as directed |
| 14 | M&L PCC type B0 1:2:4 (12.5mm graded aggregate) 25mm thick as in floor finished surfaces fair and even to receive tile all as specified and as directed |
| 15 | M&L screed bed or bedding layer of cement mortar 20mm thick in CM 1:4 for laying floor finishes to receive kota stone all as specified and as directed |
| 16 | M&L machine cut Kota stone slab flooring 20-25mm thick, over cement screed baselaid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed |
| 17 | M&L Joint free Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.18 and n.exc 0.38 Sqm in floors over 15mm thick screed bed in cement mortar 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed |
| 18 | M&L joint freee Glazed coloured ceramic tiles in vertical surface 450x300x 7mm thick over 10mm redering on backing of verticles tiles in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed |
| 19 | M&L for Chequered cement concrete tiles 30cmx30cmx25mm thick, etc, jointed and pointed in neat cement slurry in floors with grey cement and no pigment over 20mm screed bed in CM 1:6 complete all as specified and as directed |
| 20 | Demolition of brick or stone/precast PCC block masonry built in cement mortar complete all as specified and directed by Engr-in-Charge. |
| 21 | M&L for Precast cement concrete type-C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge. |
| 22 | Taking down cement plaster on Brickor concrete surfaces incl racking out joints hacking for key scrubbing downwith water etc complete |
| 23 | M&L for Rendering 15 mm thick on fair faces of brick work or concrete/stone surfaces in CM 1:6, finished even &smooth without using extra cement, complete all as specified and directed |
| 24 | M & L for prepation of new plastered or unplastered surfaces of walls and applying two coats of Cement base paint over a coat of primer , complete all as specified and directed by Engr-in-Charge. |
| 25 | M&L preparation of new plastered surfces of walls and applying three coat wash complete all asspecified and as directed. |
| 26 | Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 Sqm each. |
| 27 | All as per Srl item No. 26.00here-in-before but exc 1.5 sqm but not 4 Sqm each |
| 28 | Taking down shutter of any description n.exc 1 sqm each. |
| 29 | Taking down shutter of any description exc 1 sqm and n.exc 2 sqm each. |
| 30 | Supply & fixing plain solid straight chowkats and framed wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints in 2nd class soft wood KAIL) complete all as specified. |
| 31 | Supply & fixing 35 mm thick flush shutter, solid core construction, with blocl board core and plywood face panels, commercial type and fitted to chowkhat complete all as specified and directed. |
| 32 | Supply & fixing 30 mm thick 2nd class soft wood (KAIL) glazed and skeleton shutter open rebated and prepared to receive glass, gauge etc dividedinto squares with plain chamfered or rounded, mitred and rebated sash bars any numbers complete all as specified and directed |
| 33 | Supply & fixing 100mm mild steel butt hinges medium weight , cold rolled complete all as specified and as directed |
| 34 | Supply & fixing75mm mild steel butt hinges medium weight , cold rolled complete all as specified and as directed |
| 35 | Supply & fixing 200mm long Aluminium anodisedl barrel tower bolt of extruded section and fixed complete all as specified and as directed |
| 36 | Supply & fixing 150mm long Aluminium anodisedl barrel tower bolt of extruded section and fixed complete all as specified and as directed |
| 37 | Supply & fixing 125mm extruded aluminium alloy handles febricated type anodised complete all as specified and as directed |
| 38 | Supply & fixing 100mm extruded aluminium alloy handles febricated type anodised complete all as specified and as directed |
| 39 | Supply & fixing 300mm Aluminium alloy, anodised,sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed |
| 40 | Hacking out old broken glass panes (any thickness size quality or description ) from wooden frame fixed with oil putty or beads area not exc 0.5 Sqm each all as directed |
| 41 | Supply & fixing 4mm thick glass pan ordinary quality and glazing with oil putty in square not exc 0.5 sqm each pane. |
| 42 | M&L for preparation of wood and wood based material surface of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primercomplete all as specified and as directed |
| 43 | M&L for one coat of synthetic enamel paint on old wooden based material surface of any description, not otherwise described over 10cm width or girth complete all as specified and as directed |
| 44 | M&L prepation of new or previously untreated surfaces of steel andapplying two coat of Synthetic enamel paint over a coat of red oxide primer incl preparing new zink or galvanised surface by coating mordant solutionon CGI/PGI Sheets. |
| 45 | M&L prepation of old surfaces of steel andapplying two coat of synthetic enamel paintcomplete all as specified and as directed. |
| 46 | Supply & fixing in repair viterious china wash down water closet pan (pedestal pattern) white (excluding fixing bolts, flushing cistern and flush pipe) and incliding white plastic water closet seat cover with mild steel CP or aluminisied hinging device complete all as specified and as directed by Engr-in-Charge |
| 47 | Supply & fixing in repair PVC flushing cistern valveless syphonic action type flushing cistern low level 10 Ltrs white with inlet ball valve float and handle incl bracket. |
| 48 | Supply & fixing in repair PVC connection pipe 15mm size with PTMT nut of length 450mm |
| 49 | Supply & fixing in repair 15mm Cast copper alloy, Chromium PlatedBib taps fancy type with crutch or butterfly handle, screwed for iron pipe or for brass pipe of for ferrule and fixed |
| 50 | Supply & fixingin repair 15mm Stop valve/angle cock,fancy type, chromium plated with long shunk and cup (cncealed type) high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed |
| 51 | Taking up or down steel water tubing of 15mm dia bore and connection incl cleaning for refixing or removal to stores all as specified and as directed |
| 52 | M&L 16mm outer dia 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches. |
| 53 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/blankets, any thickness, including cover fillets all as specified and as directed by Engr-in-Charge. |
| 54 | Dismantling tillets timber scantling as in fillets, rails, posts, rafters, purlins etc under 40 Sqcm in section complete all as specified and as directed by Engr-in-Charge |
| 55 | M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 13 Sqcm but not exceeding 25 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or brads complete all as specified and directed |
| 56 | M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 3 Sqcm but not exceeding 6 Sqcm in square, rectangular or traingular in section, bullnosed, splayed, chamfered or rounded on one edge or face complete all as specified and directed |
| 57 | S&F 12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber rame work complete, all as specified and directed |
| 58 | S&F 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work as in ceiling complete all as specified and directed |
| 59 | M&L for grinding and polishing of existing kota stone all as specified and directed |
| 60 | Taking down carefully copper or aluminium point wiring (light, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants,sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. |
| 61 | M&L for Point wiring for light/fan/bell with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing caping with all accessories and1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cablefor earth continuity connected to common earth dolly incl MS sunken box with 3mm thick pre laminated hylum sheet/PVC box flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point or bell/buzzer pointcontrolled by one switch. |
| 62 | All as per Srl item No 61.00 here in before but usingcable size 2.5 Sqmm for one 3 pin socket outlet 5 Amps independent board. |
| 63 | All as per Srl item No 61.00 here in before but usingcable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board. |
| 64 | Supply & fixing Switch piano flush type 5 Amps, single pole one way. |
| 65 | Supply & fixing Switch socket combination 2 in 1, and 3 and 2 pin, 5 Ampsflush type. |
| 66 | Supply & fixing Switch socket combination 2 in 1,5 and 15 Ampsflush type. |
| 67 | Supply and fixingLED 1x18/20 Watt, 220 V, AC decorative box type fitting with driver, holder including LED tube ligh having lumen out put 100lm/wattt,CCT:6500K , PF>0.9, and connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 68 | Supply & fixingCeiling rose on PVC squre block surface bakelite, two to three terminals. |
| 69 | Supply & fixing Lamp holder, PVC/Polycarbonate type with back plate suitable forbatten fittings |
| 70 | Supply and fixing LED bulb 12 watt, 230 volts |
| 71 | Supply & fixing in replacement Sheet metal enclosure for DB\"s Double door,single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed. |
| 72 | Supply & fixing in replacement Sheet metal enclosure for DB\"s Double door,single pole and neutral, 240V, 12 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed. |
| 73 | Supply and fixing in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 40 to 63Amp in the MCB DB complete with connection testing and commissioning. |
| 74 | Supply and fixing in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SP 5 to 32 Amp in the MCB DB complete with connection testing and commissioning. |
| 75 | Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in soft /Loose soil for laying of cable all as specified and directed and as directed. |
| 76 | Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed |
| 77 | Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified. |
| 78 | Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I. |
| 79 | Factory made ISI marked un-reinforced precast cement concrete cable cover of PCC 1:1.5:3 type A-1, conforming to class LV, flat of size 250mmx150mmx40mm, laid dry over electric cable for protection all as specified. |
| 80 | M & LLT UG cable 2 corex 16 sq mm 1100 Volts grade XLPE insulated , armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including,cable glandlugs/ thimbles/ ferrules including connecting, testing and commissioning complete for the following sizes including taking down existing LT UG cable of any sizeat site all as specified and as directed.Notes:(a)Excavation earth work and sand cushioning brick protectionand connected worketc. Shall be measured and paid separately under relevant item of schedule (b)Rate quoted deemed to include for cutting and removing of defective jointswhere required as directed. |
| 81 | M & LLT UG cable 2 corex 10 sq mm 1100 Volts grade XLPE insulated , armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including,cable glandlugs/ thimbles/ ferrules including connecting, testing and commissioning complete for the following sizes including taking down existing LT UG cable of any sizeat site all as specified and as directed.Notes:(a)Excavation earth work and sand cushioning brick protectionand connected worketc. Shall be measured and paid separately under relevant item of schedule (b)Rate quoted deemed to include for cutting and removing of defective jointswhere required as directed. |
| 82 | Supply and FixingGI tubing light grade 40 mm bore as in cable protection fixed to poles/walls or laid intrenches/under road crossing etc. all as specified and as directed. |
| 83 | Supply & fixing Sub main wiring with two single core 6 sqmm multistranded copper conductor cable, PVC insulated cable 1100 volts grade and4 Sqmm as continous earthing drawing and includingPVC casing and caping of suitable size with all acessories, complete all as specified. |
| 84 | Supply & fixing in replacement of LED Flood light fitting70 watt5000 k green/natural white , IP>66 ,grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver, with all connected accessories all as specified and directed . |
| 85 | Dismantling and M&L for Earthing complete with galvanised steel earth plate electrode of size 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and including GI iron wire of size 4 mm dia by meansof GI bolts, nuts, check nuts and washers, protected by 15mm bore GI light grade ISI marked pipe upto and including test points. Earth plate shall be surrounded by alternate layer 15cm thick of charcoal or coke and common salt all aroundbottom and top , 20cm bore GI medium grade ISI marked pipe for watering and including funnel,wire mesh,PCC chamber pit made with PCC(1:3:6) type C-1(using 20mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distancenot exceeding 50M, CI pit cover duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No.3 of SSR 2009(Part-I) and all as directed.Note:- (i) Protection pipe and earthing strip upto test point from top of the earth plate and further upto the body of electrical equipment shall be included in the unit rate of this item.(ii) Earth testing arrangement should be done by contractor as per direction of Engr-In-Charge. |
| 86 | Note : Deduction for amount of Rs 67,709.00 as listed in Schedule A Part - II ( Schedule of Credit) shall be made while awarding of contract. |